NEW GENERATION HIGH LOW SYSTEMS
|
|
- David Banks
- 5 years ago
- Views:
Transcription
1 NEW GENEATION HIGH LOW SYSTEMS NEW GENEATION TM-52-DT HIGH LOW SYSTEMS control water temperature for domestic hot water systems, shower rooms and other commercial, institutional and industrial applications Dual thermostatic water mixing valves in a simple piping arrangement provide precise water temperature control of both high and low mixed water flow ranges DUA-trol solid bimetal thermostatic control (Seven-Year Limited Thermostat Warranty) Adjustable high-temperature limit stops set for 12 F (49 ) Mixed water capacities up to 214 (81 l/min) Bronze, brass and stainless steel construction Factory-preassembled and tested systems ASPAK Sizing Program Toll-free technical support
2 New Generation Systems All New Generation High Low Systems are furnished factory assembled and tested with: Large and small TYPE TM thermostatic water mixing valves in an efficient preassembled system designed to meet both high and low demands for mixed water TYPE TM valves, powered by the DUA-trol solid bimetal thermostats with Leonard s exclusive Seven- Year Limited Thermostat Warranty TM valves with 8 F (4 ) minimum differential between supply and outlet temperatures TM valves with integral hot and cold supply checkstops, wall supports and locked temperature regulators Outlet dial thermometer (optional) and ball valve shutoff, pre-piped inlet manifold Install at any location in the piping system, regardless of pressure differentials Full-time standby service eliminates downtime should one mixing valve require maintenance DUA-trol solid bimetal thermostat directly linked to valve porting Internal parts of bronze, brass and stainless steel Locked temperature adjustment setting Adjustable high temperature limit stop Union angle checkstops (with strainers) for top or bottom supplies Selection/Specification Guide NEW GENEATION SYSTEM (MODEL#) (FINISH#) (MOUNTING#) - (OPTION#) MODEL TM-42A* TM-52* TM-82* TM-92* TM-152A* TM-22B* *ASSE Standard 117 and SA listed 3/4 inlets, 1 outlet, 1-35 ( l/min) 3/4 inlets, 1 outlet, 1-5 ( l/min) 1 inlets, 1-1/4 outlet, 1-8 ( l/min) 1-1/4 inlets/outlet, 1-9 ( l/min) 1-1/4 inlets, 1-1/2 outlet, ( l/min) 2 inlets/outlet, ( l/min) FINISH F P ough Bronze hrome Plated MOUNTING O STSTL E STSTL EXP BWE E BWE EXP OPTIONS DT T Exposed Assembly Stainless Steel ecessed abinet Stainless Steel Exposed abinet Baked Enamel ecessed abinet Baked Enamel Exposed abinet Dial Thermometer (standard on abinet Models) Test onnection Piping on Outlet TM-22B 2
3 New Generation High Low Systems SAMPLE SPEIFIATION Leonard Model TM-, inlets, outlet minimum flow capacity (see chart, page 5) maximum flow PSI system pressure drop Large TYPE TM thermostatic water mixing valve, small TYPE TM valve, DUA-trol solid bimetal thermostat with Seven-Year Limited Warranty, color-coded dials, locking temperature regulator handles, adjustable limit stops set for 12 F (49 ), integral hot and cold supply checkstops Outlet ball valve shutoffs and optional color-coded dial thermometer, inlet piping manifold Factory-preassembled and tested, rough bronze finish System shall provide full-time standby service should one mixing valve require maintenance and shall be piped according to Leonard s required piping method For abinet Assembly Systems add: System shall be mounted in a recessed stainless steel cabinet with hinged door and lock (see cabinet options, page 2 in Selection/Specifications Guide). New Generation High Low Systems are not dependent upon a circulating pump for minimum flow performance New Generation Systems can be installed at any location in the domestic hot water system TM-42A TM-52 TM-82 TM-92 TM-152A TM-22B 1-35 ( l/min) 3/4 inlets, 1 outlet 1-5 ( l/min) 3/4 inlets, 1 outlet 1-8 ( l/min) 1 inlets, 1-1/4 outlet 1-9 ( l/min) 1-1/4 inlets/outlet ( l/min) 1-1/4 inlets, 1-1/2 outlet ( l/min) 2 inlets/outlet TM-42A TM-52-DT-STSTL E 3
4 O. ANSTON I USA F TYP TM US. Patents 2.97, 3,61, ,76 1 LEO NAD ASSE VAL VE THEMOSTATI US. Patent 77 & 3,61, ,76 O F PE TM AN 1 12 STON.I. U.S.A. LEO NAD ASSE 117 ASSE 117 VAL 4 2 VE O F THEMOSTATI TYPE TM ts 2.97,77 & 3,61, ,76 AN 1 12 STON.I. U.S.A. equired Piping Methods equired Piping Method #2 For systems recirculating up to 8 METHOD #2 NOTE: THIS PIPING METHOD IS USED FO MODEATE FLOW SYSTEMS WHEE THE IULATED FLOW IS EIGHT (8) O LESS. HIGH TEMPEATUE FIXTUES equired Piping Method #4 For systems recirculating 8 to 25 METHOD #4 NOTE: THIS PIPING METHOD IS USED FO MODEATE FLOW SYSTEMS WHEE THE IULATED FLOW IS EIGHT (8) TO TWENTY FIVE (25). HIGH TEMPEATUE FIXTUES TEMPEED FIXTUES TEMPEED FIXTUES THEMOMETE BALL FO SETUP (OPTIONAL) THEMOMETE BALL FO SETUP (OPTIONAL) HOT WATE SOUE HEAT TAP HEK TEMPEED IULATO ISOLATION T AQUASTAT HOT WATE SOUE HEAT TAP ETUN LINE WITH HEK (FULL ETUN LINE SIZE) TEMPEED IULATO HEK ISOLATION T AQUASTAT HEK HEK BALANING #2 WITH HEK OLD SUPPLY BALANING HIGH TEMPEATUE ETUN IULATO OLD SUPPLY HIGH TEMPEATUE ETUN BALANING #1 TEMPEED ETUN IULATO equired Piping Method #5 For systems recirculating over 25 METHOD #5 NOTE: THIS PIPING METHOD IS USED FO HIGH FLOW SYSTEMS WHEE THE IULATED FLOW IS TWENTY FIVE (25) O GEATE HIGH TEMPEATUE FIXTUES TEMPEED FIXTUES THEMOMETE BALL FO SETUP (OPTIONAL) ETUN LINE (FULL ETUN LINE SIZE) T HOT WATE SOUE HEAT TAP HEK TEMPEED IULATO ISOLATION AQUASTAT HEK BALANING #2 WITH HEK OLD SUPPLY BALANING #1 HIGH TEMPEATUE ETUN TEMPEED ETUN IULATO See page 6 for calculating the size of hot water bypass line. 4
5 Flow apacities MODEL TM-42A IN 3/4" 19mm MIN. SYSTEM PESSUE DOP (PSIG) OUT FLOW " mm PSI BA TM-52 TM-82 TM-92 3/4" 19mm 1" 25mm 1" 1 1/4" 25mm 32mm 1 1/4" 1 1/4" 32mm 32mm TM-152A 1 1/4" 1 1/2" mm 38mm " 2" TM-22B 51mm 51mm ASSE STANDAD 117 & SA LISTED Maximum Flow apacity Note: The New Generation model must be selected based upon the following: Maximum system demand for mixed water System pressure drop* Designer s estimated minimum mixed water flow requirement * System pressure drop = the pressure available at the inlet of the mixing valve minus the pressure required to operate the farthest fixture, i.e., shower valve, in the building Minimum Flow: TM-22B 1. TM-152A 1. TM TM TM TM-42A 1. PESSUE DOP, P.S.I.G. SYSTEM BA FLOW ATE, aution: All thermostatic water mixing valves have limitations. They will not provide the desired accuracy outside of their flow capacity range. onsult the above chart and graph and make certain minimum flow is greater than as shown above. 5
6 LEO 117 US. Patent 77 & 3,61, ,76 O. PE TM AN.I. Features, Options SUFFIX T BALL BALL NAD VAL VE THEMOSTATI TEMPEED WATE TO BUILDING STON U.S.A. FULL LINE SIZE FOM OUTLET SUFFIX T Test onnection Piping Eliminates the need to turn distant showers and sinks on and off throughout the building during setup. The required setup flows are established using the Test onnection Ball Valve (with hose connection) while the additional Ball Valve is in the closed position.this optional piping is furnished as part of the High Low System (Exposed Assemblies only). New Generation High Low Systems New Generation Systems are powered by Leonard s DUA-trol solid bimetal thermostats, highly responsive, not subject to puncture or fatigue, and not damaged when temporarily exposed to excessive temperatures. DUA-trol thermostats used in New Generation High Lows carry Leonard s exclusive Seven-Year Limited Warranty. Leonard s New Generation Systems provide simple, economical and dependable control of water temperature for and within domestic hot water systems when correctly sized, installed and maintained. Sizing the Hot Water ByPass Line For equired Piping Method #5 The following information is needed to size this line properly: 1. Flow of the recirculated water (Flow) 2. Temperature of the hot water (T hot) 3. eturn temperature (T return) 4. Outlet temperature of the mixing valve (T outlet) alculate the amount of hot water needed to restore the outlet recirculated water temperature to the original setting and select the line size needed to accomplish this using the formula below. Use the Type L table to determine the size. A properly sized Hot Water ByPass Line will prevent the possibility of the system reaching full hot water at any time. T outlet T return T hot T return X Flow = Gallons of Hot Water equired GPH hot Type L water req d line size 5 1/2 8 3/ / /2 Note: This chart is based upon flow at 5ft/sec max. Once a draw occurs (i.e., a faucet is opened) the pump deadheads and cold and hot water are introduced into the system. At this point recirculation is virtually nonexistent. This hot water bypass line will be needed when more than 8-1 of additional hot water is needed to maintain the recirculated water temperature. WANING! No two piping systems are alike! The Piping Methods detailed in this bulletin serve only as a guide to assist the specifier in the design of a hot water piping system. The specific characteristics of each installation must be considered by the design professional. Note: All specifications are subject to change without notice! 136 Elmwood Avenue ranston, I 291 USA t f info@leonardvalve.com LV-11B 9/9 Printed in the U.S.A. 6
CLASSIC HIGH LOW MANIFOLD SYSTEMS
LASSI HIGH LOW MANIOLD SYSTEMS LEONARD LASSI HIGH LOW MANIOLD SYSTEMS control water temperature for domestic hot water systems, shower rooms and other commercial, institutional and industrial applications
More informationCOMPLETE WATER TEMPERATURE CONTROL SYSTEM
OMPLETE WATE TEMPEATUE ONTOL SYSTEM MEGATON omplete Water Temperature ontrol Systems regulate water temperature for building hot water systems and other commercial, institutional and industrial applications.
More informationECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION
- 3 5 ps i kg/cm ASSE 7 VAL VE - CO. 3 5 THEMOSTATIC TYPE TM US. Patent 77 & 3,,95 3.5,7.I. - 3 5-3 5 Submittal Data Sheet S-533Z-LF April, COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX MEGATON LEAD FEE
More informationMODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013
TERMOSTATI MIXING VALVE 5-1/2" 140mm EO-MIX Submittal Data Sheet S-827-LF February 2013 MODEL 270-LF LEAD FREE TERMOSTATI POINT OF USE MIXING VALVE MODEL ½ inlets, ½ outlet, (MIPS connections) MATERIALS:
More informationECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION
- 3 5 kg/cm ASSE 7 - CO. 3 5 THEMOSTATIC TYPE TM US. Patent 77 & 3,,95 3.5,7.I. - 3 5-3 5 COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX Submittal Data Sheet S-5Z-LF August, MEGATON LEAD FEE MODEL 3NB-LF
More informationECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION
- 3 5 kg/cm C AS SE 7-3 5 THEMOSTATIC H - 3 5 3 5 - COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX Submittal Data Sheet S-5Z-LF August, MEGATON LEAD FEE MODEL NB-LF HOT & COLD INLETS MIXED OUTLET ¼ ETUN
More informationECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION
- 5 kg/cm 7 7-5 - 5-5 Submittal Data Sheet S-5Z-LF April, COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX MEGATON LEAD FEE MODEL NB-LF ¾ HOT & COLD INLETS MIXED OUTLET ¾ ETUN PIPING. to GPM(.7 to 7 l/min)
More informationWATER TEMPERATURE CONTROL SYSTEMS
Mixing Safety & Performance for Over 100 Years WATER TEMPERATURE CONTROL SYSTEMS TM-2020B-LF-DT TM-2020B-2PS-LF MEGATRON 6NB-LF ASSE 1017 LOW LEAD CERTIFIED Made in the USA with Domestic and Imported Parts
More informationMEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF
6 1-1 3 8 5 6 1 6 2 1 4 1 8 6 8 kg/cm2 11 psi 1 16 1 1 1 6 1 ASSE 117 VAL VE -1 CO. 3 6 8 5 1 THEMOSTATIC T YPE TM AN STON 1 1.I. U.S.A. 6 1-1 6 3 8 1 5 1 1 6 1-1 6 3 8 5 1 1 1 H C Bulletin M-115Z August,
More informationECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING
4 4 5-4 3 8 4 4 5-3 8 4 TERMOSTATI 4 3 4 5-8 4 TERMO STATI TERMOSTATI 4 4 5-3 8 4 4-3 8 4 4 5 OMPLETE WATER TEMPERATURE ONTROL STATION EO-MIX Valve assemblies are ASSE 7 listed Submittal S-596Z-LF August,
More informationECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION
1-1 3 1 5 1 kg/cm 11 1 1 1 1 1 1-1 3 1 5 1 1-1 3 1 5 1 1-1 3 5 1 COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX Valve is ASSE 117 Certified Submittal S-11-1-LF August, 1 MEGATON LEAD FEE MODEL XLLF 1 HOT
More informationINSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed
4 AS SE 1 17 6 1-1 3 LEONAD C F 6 8 14 4 5 1 1 4 1 17 6 1-1 F 3 LEONAD C 6 8 14 4 5 1 1 INSTALLATION ADJUSTMENT SEVICE HIGH-LOW MANIFOLD SYSTEMS TM-4A Valve assemblies are 117 listed Valve assemblies are
More informationINSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed
4 2 AS SE 1 17 6 8 2 3 1 LEONAD 4 5-1 6 C F 14 1 12 4 2 1 17 6 8 2 3 1 LEONAD 4 5-1 6 C F 14 1 12 BULLETIN G-11F February 29 INSTALLATION ADJUSTMENT SEVICE HIGH-LOW MANIFOLD SYSTEMS TM-42A Valve assemblies
More informationMEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF
5-1 8 1 1 2 4 8 6 8 kg/cm 2 11 psi 1 1 1 LEO NAD 17 VAL VE - C O. THEMOSTATIC PE TM 8 5 1 CAN STON 1.I. U.S.A. - 8 1 5 1-8 5 1 1 H C Bulletin M-11Z January 14 MEGATON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD
More information30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION
ASSE 117 1-1 2 6 3 4 5 4 1-1 2 6 3 4 5 BULLETIN G-26-34 January 216 INSTALLATION ADJUSTMENT SEVICE TYPE TM-26-F-DT-34, TM-26-LF-F-DT-34 IMPOTANT! Provide valve serial number (stamped on cover of valve)
More informationINSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF
LEO ASSE R US. Patent 770 & 3,061,195 3.152,760 O. PE TM RAN STON R.I. Bulletin G11D April 2014 INSTALLATION ADJUSTMENT SERVIE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF,
More informationINSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF
2 6 4 1 O. RANSTON RI USA TYP TM U S. Pat en ts 2. 97, 3, 6 1,1 95 3.15 2,76 8 2 3 R 4 5-1 6 F 14 1 12 Bulletin G-12 August, 218 INSTALLATION ADJUSTMENT SERVIE NEXT-GENERATION MANIFOLD SYSTEMS TM-52B-,
More informationINSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)
OT BULLETIN P-15 June, 2006 INSTALLATION ADJUSTMENT SERVIE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM-186-5015-PRV, 8015, 12520, 15020) IMPORTANT! Provide valve serial
More informationINSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982
Bulletin LV-98 March 010 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES & LV-98 IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! ASSE 1017
More informationTMV45 & TMV80 Standard Thermostatic Mixing Valves
Reliable liquid-filled thermostat Integral strainer checkstops on inlets Adjustable set point within temperature range Accurate temperature control Positive shutoff of hot supply when cold supply is lost
More informationDOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET
4 1-1 3 R 8 14 4 5 4 1 2 1 4 8 6 kg/cm 2 11 psi 8 1 1 1 14 1 4 ASSE 117 1-1 3 R 8 14 4 5 THERMOSTATI H 1 1 4 1-1 3 R 8 14 4 5 1 1 4 1-1 3 R 8 14 4 5 1 1 M-122Z September 1 MEGATRON MODEL 6N INSTALLATION
More informationINSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82
Bulletin XL-38 March 00 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-3, XL-8 IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!!
More informationINSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)
Bulletin G-2D-1 September 2008 INSTALLATION ADJUSTMENT SERVIE TERMOSTATI WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY) IMPORTANT! This Bulletin covers valves built after June 2001, starting
More informationHL45, HL80 Thermostatic High-Low Valves
Lead-Free Brass Design Reliable Liquid-Filled Thermostat with 10 year warranty Integral Strainer Checkstops on Inlets Adjustable Set Point within Temperature Range Accurate Temperature Control to within
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV-98 Old Rev. LV-98 February 1 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES, LV981-LF &, -LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering
More informationINSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS
ASSE 1 17 TERMOSTATI 4 1-1 F 3 R 8 14 4 5 1 1 ASSE 1 17 TERMOSTATI VALVE O. RANSTON RI USA TYP TM US. Patents 2.97, 3,61,195 3.152,7 4 1-1 F 3 R 8 5 14 4 1 1 VALVE O. RANSTON RI USA TYP TM US. Patents
More informationMEGATRON MODEL 2, 3, 4, and 5
MEGATRON MODEL 2, 3, 4, and 5 BULLETIN M-1020A 2/02 INSTALLATION ADJUSTMENT SERVICE COMPLETE WATER TEMPERATURE CONTROL STATION DOMESTIC OUTLET TEST/SETUP CONNETION RETURN LINE FROM BUILDING RETURN LINE
More informationMEGATRON MODEL TA, TA-LF
6 1-1 2 LEONAD 6 3 8 6 C H LEONAD 116 LEONAD VALVE CO. CANSTON I 291 8 2 3 1 LEONAD -1 6 MODEL 21 Water Mixer 117 1 6-1 2 3 LEONAD 6 8 6 8 2 3 1 LEONAD -1 6 MEGATON MODEL TA, TA-LF Bulletin G-1L August,
More informationOUTLET LEONARDH THERMOSTATIC INSTALLATION
Bulletin G-AT June 2012 INSTALLATION ADJUSTMENT SERVIE ALLTERNATIVE TEMPERATURE TERMOSTATI WATER MIXING VALVES TYPE TM-50-AT, 80-AT, 150-AT, 200-AT IMPORTANT! Provide valve serial number, (stamped on cover
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin 82 August, 208 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES, -LF,, -LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!!!
More informationINSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125
EMERGENY VALVE F EMERGENY VALVE INSTALLATION SETUP AND OPERATING INSTRUTIONS WATER SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125 IMPORTANT! Provide valve serial number, (stamped on valve
More informationINSTALLATION ADJUSTMENT SERVICE
Bulletin XL-670 July 201 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE MODEL XL-670-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! ECO-MIX
More informationMODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm
WATER MIXER WATER MIXER TRERMOSTATIC WATER MIXER TRERMOSTATIC C TRERMOS TA TIC WA TER MIXER MODEL TA Bulletin P-7A-4 May 2011 (NEW STYLE) THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING
More informationINSTALLATION ADJUSTMENT SERVICE
ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-26, TM-26-LF BULLETIN G-26 January 2014 IMPORTANT! Provide valve serial number (stamped on cover of valve) when ordering parts!! Valve manufactured after
More informationHose Stations. Leonard THS Thermostatic and SW/CW Manual Hose Stations
Hose Stations Leonard THS Thermostatic and SW/CW Manual Hose Stations Thermostatic controlled for washdown and processing applications and manual controlled or industrial washdown applications Hose Stations
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV-101 Old Rev. LV-101 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-983, LV-983-LF & LV-984, LV-984 -LF IMPORTANT! Provide valve serial number, (located on valve
More informationLEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).
2 0 2 4 6 80 kg/cm psi 2 11 LEO NARD 8 10 1 10 0 1 TERMOSTATI 1 10 0-10 0 R F VALVE O. RANSTON RI USA TYP TM US. P aten ts 2.970, 3,06 1,195 3.152,76 0 30 80 1 50 100 1 Bulletin G18E May 08 INSTALLATION
More informationHOT INLET COLD INLET INSTALLATION
EMERGENY VALVE F EMERGENY VALVE Bulletin G-4 INSTALLATION SETUP AND OPERATING INSTRUTIONS WATER SYSTEMS TYPE TM-600, TM-600-LF, TM-650, TM-800, TM-800-LF, TM-850, TM-850-LF TM-5100, TM-5100-LF, TM-5125,
More informationINSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)
ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA) BULLETIN P-15A January, 2014 IMPORTANT! Provide valve serial number when ordering
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin XL-150 February 2015 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-150, XL-150-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
. Bulletin XL-200 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES XL-200, XL-200-LF, XL-200-SW, XL-200-SW-LF IMPORTANT! Provide valve serial number, (located on valve cover) when
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV-99 July, 01 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE LV-981A, LV-981A-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! INSTALLATION
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV-0 September 01 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE LV-0, LV-0-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! INSTALLATION
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin GLV- January 014 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE LV-, LV--LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! INSTALLATION
More informationOUTLET HOT INLET COLD INLET INSTALLATION
Bulletin G-29 December 2007 INSTALLATION ADJUSTMENT SERVICE TYPE TM-28 IMPORTANT! Provide valve serial number (stamped on cover of valve) when ordering parts!! Valve manufactured after July 2007 starting
More informationINSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B
2 4 1 11 7 6 8 2 3 4 5-1 6 F 14 TERMOSTATI 1 12 2 ASSE 117 6 4 1 8 2 3 4 5-1 6 F 14 TERMOSTATI 1 12 Bulletin G-11E June 29 INSTALLATION ADJUSTMENT SERVIE IG-LOW MANIFOLD TM-22B Valve assembly is ASSE 117
More informationWall Mounted Shower Systems
Wall Mounted Shower Systems Leonard Surfashower Wall-Mounted Shower Systems Offered in thermostatic or pressure actuated models with standard or ADA compliant shower head/hand shower configurations. Wall
More informationINSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed
ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed *Valve is CUPC listed IMPORTANT! Provide valve serial number
More informationMODEL 210, 210-LF THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUCTIONS
Bulletin G-210 January, 2014, 210-LF TERMOSTATI WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUTIONS IMPORTANT! Provide valve serial number (begins with serial no. -1000) when ordering parts!!
More informationINSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS
OT ASSE 117 4 2 1-1 2 3 R F 8 14 4 5 1 12 ASSE 117 VALVE O. RANSTON RI USA AS SE 117 TYP TM US. Patents 2.97, 3,61,195 3.152,7 4 2 1-1 2 F 3 R 8 5 14 4 1 12 VALVE O. RANSTON RI USA ASSE 117 U S. Pate nt
More informationINSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550
C BULLETIN G-6A January 2012 INSTALLATION SETUP AND OPERATING INSTRUCTIONS WATER SYSTEM TM-500, TM-550 IMPORTANT! Provide valve serial number (located on valve body) when ordering parts!! Starting with
More informationINSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS
OT ASSE 117 TERMOSTATI 4 2 1-1 2 3 R F 8 14 4 5 1 12 ASSE 117 TERMOSTATI LF VALVE O. RANSTON RI USA TYP TM LF 4 2 1-1 2 F 3 8 5 14 4 1 12 LF VALVE O. RANSTON RI USA TYP TM LF Bulletin G11N5 March 215 INSTALLATION
More informationINSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS
OT ASSE 117 4 2 1-1 2 3 R F 8 14 4 5 1 12 ASSE 117 VALVE O. RANSTON RI USA AS SE 117 TYP TM US. Patents 2.97, 3,61,195 3.152,7 4 2 1-1 2 F 3 R 8 5 14 4 1 12 VALVE O. RANSTON RI USA A SSE 117 TYP TM U S.
More informationTA-300, TA-300-LF, TA-350, TA-350-LF
Bulletin G-5 INSTALLATION SETUP AND OPERATING INSTRUCTIONS EMERGENCY MIXING VALVE SYSTEM TA-300, TA-300-LF, TA-350, TA-350-LF IMPORTANT! Provide valve serial number (located on valve body) when ordering
More informationINSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF
1 ASSE 117 3-1 F 8 5 1 TERMOSTATI 1 1 ASSE 117 1-1 F 8 3 5 1 TERMOSTATI 1 1 Bulletin G-11E August, 18 INSTALLATION ADJUSTMENT SERVIE IG-LOW MANIFOLD TM-B, TM-B-LF IMPORTANT! Provide serial numbers for
More informationINSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF
2 4 1 11 7 8 2 3 4 5-1 F 14 1 12 2 4 1 ASSE 117 2 3 4 5-1 F 8 14 1 12 Bulletin G-11E April 214 INSTALLATION ADJUSTMENT SERVIE IG-LOW MANIFOLD TM-22B, TM-22B-LF IMPORTANT! Provide serial numbers for both
More informationINSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF
2 1 ASSE 117 2 3-1 F 8 5 1 TERMOSTATI 1 12 2 ASSE 117 1 2 3-1 F 8 5 1 TERMOSTATI 1 12 Bulletin G-11E April 217 INSTALLATION ADJUSTMENT SERVIE IG-LOW MANIFOLD TM-22B, TM-22B-LF IMPORTANT! Provide serial
More informationWALL MOUNTED SHOWER SYSTEMS
WALL MOUNTED SHOWER SYSTEMS Wall mounted shower systems for schools, institutions, clubs, industrial and shipboard applications. Thermostatic, pressure balanced, or single temperature models Single or
More informationINSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A
C ASSE 1017 BULLETIN G-6B March 2009 INSTALLATION SETUP AND OPERATING INSTRUCTIONS WATER SYSTEM * TM-500A, TM-550A IMPORTANT! Provide valve serial number (located on valve body) when ordering parts!! *ASSE
More informationINSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed
4 6 2 8 6 4 8 kg/cm 2 11 psi 1 1 6 1 1 4 1 4 6 4 1-1 6 3 8 14 6 1-1 4 5 1 1 6 3 8 14 4 5 1 1 TERMOSTATI 4 6 1-1 6 3 8 14 4 5 1 1 TERMOSTATI 4 6 1-1 6 3 8 14 4 5 1 1 4 6 1-1 LE ON ARD 6 3 8 14 4 5 1 1 EO-MIX
More informationNote: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.
Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet Angle Checkstop Angle Checkstop Hot Water Inlet G3700LF Cold Water Inlet Installation 1.
More informationInstallation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves
Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Hot Water Tempered Water Outlet Cold Water Tempered Water Outlet Redundant Thermostatic Mixing Valve Hot Water
More informationWALL MOUNTED SHOWER SYSTEMS
Mixing Safety & Performance for Over 100 Years WALL MOUNTED SHOWER SYSTEMS Made in the USA with Domestic and Imported Parts 1360 Elmwood Ave., Cranston, RI 02910 TF: 800.222.1208 P: 401.461.1200 F: 401.941.5310
More informationSubmittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION
! APPROXIMATE DIMENSIONS A = 3-3 B = 3-10-1/2 C = 4 D = 9-1/2 *Image not to scale* WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.
More informationAutomatic Temperature Controller (ATC)
NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet
More informationOUTLET LEONARD THERMOSTATIC INSTALLATION
BULLETIN G-2B-TMS August, 2018 INSTALLATION ADJUSTMENT SERVIE STEAM AND WATER MIXING VALVE TYPE TMS-25, 50, 80, 125, 150 IMPORTANT! Provide valve serial number (stamped on cover of valve) when ordering
More informationSubmittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified
! APPROXIMATE DIMENSIONS A = 3-11 B = 3-9 C = 4-1/2 D = 1-1 *Image not to scale* WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.
More informationSECTION DOMESTIC WATER PIPING SPECIALTIES
SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationMixing Safety and Performance
Mixing Safety and Performance For For Over Over 100 100 Years Years About Leonard Valve Company Mixing Safety and Performance At Leonard Valve Company, our passion is to provide safe hot water for our
More informationHYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F
34-200 SERIES HYDRONIC TEMPERING VALVES The Apollo Model TV (34-200 Series) thermostatic mixing valve provides non-asse extension of water heater capacity and hot water temperature control in hydronic
More informationInstallation S
Installation S59-3080 Thermostatic Mixing Valve with Optional Cabinet S59-3080RE (with Recess-Mounted Enamel Cabinet) S59-3080RS (with Recess-Mounted Stainless Steel Cabinet) S59-3080SE (with Surface-
More informationBRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9
BRADLEY THERMOSTATIC MIXING VALVES Bradley Corporation, a leader in the manufacture of fixtures and plumbing products, produces four lines of thermostatic mixing valves (TMVs). Bradley Navigator High-Low
More informationInstallation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves
Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet Cold Water Thermometer Hot Water Inline Check Redundant Thermostatic Mixing Valve Angle Checkstops
More informationNote: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF
Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer 1/2" OD Copper Tube Inlets Hot Water Inlet Cold Water Inlet G3600LF Installation 1. Install valve in
More informationModel SFMV Series. Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves
Model SFMV Series Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves APPLICATION: The Acorn SFMV Series Supply Fixtures can be accurately referred to as a High/Low valve fixture, compliant
More informationModel T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!
Application Legend thermostatic mixing valves are designed for applications requiring temperature control, scald prevention and reduction of thermal shock in domestic potable water distribution (Model
More informationDomestic Hot Water Systems and Plumbing Products
Domestic Hot Systems and Plumbing Products Taco Catalog #100-117 Effective Date: 09/02/15 Supersedes: 06/22/15 Printed in USA Domestic Hot Recirculation Taco Domestic Hot Plumbing Products Since 1920 Taco
More informationInstallation S
Installation S59-3045 Thermostatic High-Low Mixing Valve (HL45) with Optional Cabinet S59-3045 (Valve Only) S59-3045RE (with Recess-Mounted Enamel Cabinet) S59-3045RS (with Recess-Mounted Stainless Steel
More informationInstallation S
Installation S59-3080 Thermostatic High-Low Mixing Valve (HL80) with Optional Cabinet S59-3080RE (with Recess-Mounted Enamel Cabinet) S59-3080RS (with Recess-Mounted Stainless Steel Cabinet) S59-3080SE
More informationInstallation S
Installation S59-3200 Thermostatic Mixing Valve (HL200) with Optional Cabinet S59-3200RE (with Recess-Mounted Enamel Cabinet) S59-3200RS (with Recess-Mounted Stainless Steel Cabinet) S59-3200SE (with Surface-Mounted
More informationInstallation S
Installation S59-2025 Thermostatic Mixing Valve (TMV25) with Optional Cabinet S59-2025RE (with Recess-Mounted Enamel Cabinet) S59-2025RS (with Recess-Mounted Stainless Steel Cabinet) S59-2025SE (with Surface-Mounted
More informationARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL
ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL Manufacturer's Warning To reduce the possibility of injury due to scalding,
More informationInstallation & Operation Manual Models: SIT030 - SIT119
SIT-I-O Rev N Installation & Operation Manual Models: SIT030 - SIT119 CAUTION: The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as listed in Clinical
More informationOwner s Manual Therma-Stor II Heat Recovery System
PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.
More informationSECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Codes and Standards: A. Plumbing Code Compliance: Comply with applicable portions of National Standard Plumbing Code pertaining to selection and installation of Plumbing materials
More informationInstallation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119
SIT-I-O Rev B Installation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119 WARNING This manual must only be used by a qualified heating installer / service technician. Read
More informationThermostatic mixing valves with interchangeable cartridges
www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems
More informationDigiTemp. Digital Water Tempering System. PVI.com
DigiTemp Digital Water Tempering System PVI.com DigiTemp Digital Water Tempering System DigiTemp is a domestic hot water main mixing station for commercial and institutional facilities that intelligently
More informationInstallation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014
Installation S59-3400 HL2X2 High Capacity Manifold System Table of Contents Supplies Required... 3 Rough-Ins... 3 Connect Supply Lines and Install Thermometer... 4 Adjust Temperature and Test Unit... 5
More information5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341
NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic
More informationCOBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.
COBREX Semi-Instantaneous Steam-Fired Domestic Hot Water Generator ENGINEERED DUPLEX ALLOY Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty PVI.com Steam-Fired Domestic Hot Water Generator COBREX
More informationHORNE 15 and 20 thermostatic mixing valve specification manual 2009
HORNE 15 and 20 thermostatic mixing valve specification manual 2009 contents HORNE introduction 1-4 history 1 why TMVs? 3 why HORNE? 4 HORNE HORNE 15 TMV 5 4th connection 6 HORNE HORNE 20 TMV 7 HORNE appendix
More informationA. This Section includes the following domestic water piping specialties:
SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationAM Series Proportional Thermostatic Mixing Valve
AM-1 1070 Series Proportional Thermostatic Mixing Valve PATENTED, WIT DUAL ASSE 1070 AND 1017 ERTIFIATION, IAPMO AND SA LISTING IN ONE VALVE PRODUT DATA PRODUT INFORMATION SPEIFIATIONS Media Temperature
More informationBRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)
BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version) Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash,
More information. ECTION METERS AND GAGES
. ECTION 230519 - METERS AND GAGES PART I - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 00 thru 01 Specification
More information5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)
Based On The MV7 Master Mixing Valves APPLICATION: The Acorn SFMMV Series Multi-Valve Supply Fixtures can be accurately referred to as a High/Low Multi-Valve fixture, compliant with the temperature control
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationunion swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve
VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging
More informationSPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION
SPH Series Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA
More information