L65369 Rev Planning Guide. Effective 04/13/15

Size: px
Start display at page:

Download "L65369 Rev Planning Guide. Effective 04/13/15"

Transcription

1 L65369 Rev Planning Guide Effective 04/13/15

2 2015 Planning Guide Important Information: This Dacor Planning Guide contains that latest product information as of prill 13th, Specifications are subject to change without notice. For the most accurate and up to date planning guide pages, we recommend that you visit our web site at If you cannot access our web site via computer, please fill out the Planning Guide Update Form on the following page and FX or mail it to us. We can send you updates via or regular mail. If you need additional copies of this planning guide, please contact the Marketing Department at (800) and reference part number: L65369 Revision Thank you Dacor, all rights reserved

3 UPDTE FORM If you cannot access our web site via computer to obtain planning guide updates, fill out this form completely and fax or mail it as instructed below. We will send you updates as they are issued. Please mail this form to the address below or fax it to (626) Dacor tt: Marketing Department PO ox City of Industry, C Full Name: Company name: ddress: City: State: Zip code: Telephone number: Fax number: address: My Dacor representative: Please send updates via: Printed copy Web site:

4 Table of Contents Revised 02/18/15 WLL OVENS Discovery iq Single (DYO, DYOV) Discovery iq Double (DYO, DYOV) Distinctive Single (DTO, DTOV) Distinctive Double (DTO, DTOV) Renaissance Single (RNO, RNOV) Renaissance Double (RNO, RNOV) WRMING DRWERS Renaissance ELECTRIC COOKTOPS Discovery (MET) Distinctive (DECT) Renaissance (ETT) Renaissance Induction (RNCT) GS COOKTOPS Classic Drop-In (SGM) Discovery Slide-In (DYRTP) Distinctive Drop-In (DCT) Distinctive Slide-In (DRT) Renaissance Slide-In (EG) Renaissance Drop-In (RGC) RNGES , 48 Discovery Dual Fuel (DYRP36/48DS) Distinctive Dual Fuel (DR30D) Distinctive Electric (DR30E) Distinctive ll Gas (DR30G) Renaissance Dual Fuel (ER30D) , 48 Renaissance Dual Fuel (ER36/48D) Renaissance ll Gas (ER30G) Renaissance ll Gas (ER36G) Renaissance Electric/Induction (RNR30N) /48 Renaissance ll Gas (RNRPxxG) DUCT 6.1 HOODS Discovery Island Style (DHI) 7.1 Discovery Wall Mount (DHW) 7.2 Discovery Glass Wall Mount (PHW) 7.3 Distinctive Wall Mount (DH) Renaissance Wall Mount (EH, EHR, MH) Integrated Ventilation System (IVS, IVSR) 7.9 Custom Hood Liner (IHL) 7.10 DOWNDRFT VENTS Renaissance Slim Chassis (ERV, PRV) Classic Standard Chassis (RV) LOWERS Cabinet Style for Selected Downdraft Vents (CP) 9.1 Renaissance, In-Line (ILHSF) Renaissance, Remote (REMP) DISHWSHERS Distinctive DDW Renaissance RDW24I/RDW24S REFRIGERTION Distinctive 36 with Dispenser (DTF 4-Door) 11.1 Renaissance 24 Wine Cellar (RNF) 11.2 MICROWVES Discovery Convection Type (DCM24) 12.1 Trim Kits for bove (CTK/DCMTK/OCTK) 12.1 Discovery 24" Microwave-In--Drawer (MMD24) 12.2 Discovery 30" Microwave-In--Drawer (MMD[V]30) 12.3 Discovery Convection Type, Over Range (PCOR30) 12.4 Distinctive Stainless Steel (DMW2420S) 12.5 Trim Kits for bove (MTK/DMWTK/OMTK) 12.5 Renaissance lack Glass (DMT2420K) 12.6 Trim Kits for bove (MTK/OMTK) 12.6 OUTDOOR GRILLS Discovery (O/OS) uilt-in Trim kit for O/OS Series Grills (OGT) " Outdoor Grill Cart, for O/OS36 Grill (OC) 13.5 CKGURDS 14.1 ackguard, Stand-lone (E) 14.1 DISPENSING SYSTEMS Discovery Wine Dispensing System (DYWS) X.1

5 Table of Contents Revised 02/18/15 COMINTION INSTLLTIONS CI.1-CI.21 Drop-In Cooktop/Downdraft Vent/Single Wall Oven CI.1-CI.2 Drop-In Cooktop/Slim Downdraft Vent/Single Wall Oven CI.3-CI.4 Single Wall Oven/Drop-In Cooktop CI.5-CI.6 Cooktop/Range/Downdraft Vent CI.7 Warming Drawer/Drop-In Cooktop CI.8 Warming Drawer/Slide-In Cooktop CI.9 Warming Drawer (stacked)/slide-in Cooktop CI.10 Warming Drawer (side-by-side)/slide-in Cooktop CI.11 DCM Microwave/Warming Drawer CI.12 DMT/DMW Microwave/Warming Drawer CI.13 DCM Microwave/DTO Wall Oven/Warming Drawer CI.14 DMT/DMW Microwave/ DTO Wall Oven/Warming Drawer CI.15 DCM Microwave/DYO Wall Oven/Warming Drawer CI.16 DMT/DMW Microwave/ DYO Wall Oven/Warming Drawer CI.17 DMW Microwave/RNO Wall Oven/ Warming Drawer CI.18 DTO Wall Oven/Microwave In--Drawer/ Warming Drawer CI.19 DYO Wall Oven/Microwave In--Drawer/ Warming Drawer CI.20 RNO Wall Oven/Microwave In--Drawer/ Warming Drawer CI.21 X.2

6 DYO, DYOV Discovery iq 30 Wide Single Wall Ovens Revised 03/10/14 WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. Product tolerances: ±1/16 (±1.6 mm), unless otherwise stated. 3 1/2 (8.9 cm) 1 1/8 (2.9 cm) 1 1/8 (2.9 cm) 3 3/16 (8.1 cm) 1 1/8 (2.9 cm) Dedicated Circuit Required 240 Vac, 4-wire*, 60Hz, 30 mp. Total Connected Load** 240 Vac 60 Hz, 22.5 mp. 5.4 kw * Two 120 Vac hot (L1 and L2), one neutral, one ground. ** This specification is for reference only. See the product data label for exact specifications. HNDLE DIMENSIONS - SIDE VIEW J K Utility cutout Top of chassis F G C H D 21 7/8 (55.6) cm Control panel front Control panel side view E Conduit: 60 (152 cm) long Top of chassis C D E F G H J K 29 7/8 (75.9 cm) 28 1/4 (71.8 cm) 28 11/16 (72.9 cm) 27 3/8 (69.5 cm) 1 5/16 (3.3 cm) 6 1/2 (16.5 cm) 5 (12.7 cm) 7 7/8 (20.0 cm) 1 3/8 (3.5 cm) 23 1/2 (59.7 cm) PRODUCT DIMENSIONS 1.1

7 DYO, DYOV Discovery iq 30 Wide Single Wall Ovens Revised 03/10/14 Cutout tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated. 1 1/2 (3.8 cm) thick typical counter Recommended electrical location 29 3/4 * (75.6 cm) min. to overhang C 4 (10.2 cm) min. between cutout C 1 (2.5 cm) min. to combustible floor 3/4 (1.9 cm) support platform 3/4 (1.9 cm) support platform lternate electrical locations Toe kick CUTOUT DIMENSIONS SIDE-Y-SIDE UNDER-COUNTER INSTLLTION Recommended electrical location 1 1/2 (3.8 cm) thick typical counter 29 3/4 (75.6 cm) * min. to bottom of cabinet door C 3/4 (1.9 cm) support platform 29 3/4 * (75.6 cm) min. to overhang 3/4 (1.9 cm) support platform C 1 (2.5 cm) min. to combustible floor Recommended electrical location Toe kick CUTOUT DIMENSIONS - UNDER-COUNTER INSTLLTION 1 (2.5 cm) min. any obstructions to ventilation lternate electrical location 31 1/4 (79.4 cm) recommended () () (C) 30 (76.2 cm) 28 3/8 to 29 (72.1 cm to 73.7 cm) 27 7/16 to 28 1/4 (69.7 cm to 71.8 cm) 4 typical toe kick NOTES: CUTOUT DIMENSIONS - WLL INSTLLTION * 30 3/4 (76.1 cm) recommended CUTOUT DIMENSIONS 1. Minimum interior cabinet depth: 24 (61.0 cm). 2. 1/8 (3 mm) minimum clearance from appliance to adjacent cabinet doors/drawers. 3. Two (2) Single Ovens are not approved in a stack configuration. 1.2

8 DYO, DYOV Discovery iq 30 Wide Double Wall Ovens Revised 03/10/14 WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. Product tolerances: ±1/16 (±1.6 mm), unless otherwise stated. Dedicated Circuit Required 240 Vac, 4-wire*, 60 Hz, 50 mp. Total Connected Load 240 Vac 60 Hz, 45 mp kw * Two 120 Vac hot (L1 and L2), one neutral, one ground. ** This specification is for reference only. See the product data label for exact specifications. 3 1/2 (8.9 cm) 1 1/8 (2.9 cm) 1 1/8 (2.9 cm) 3 3/16 (8.1 cm) 1 1/8 (2.9 cm) FJ KG HNDLE DIMENSIONS - SIDE VIEW C D 21 7/8 (55.6) cm Control panel front Control panel side view E Top of chassis Conduit: 60 (152 cm) long C D E F G 29 7/8 (75.9 cm) 28 1/4 (71.8 cm) 51 1/8 (129.9 cm) 50 3/16 (127.5 cm) 15/16 (2.4 cm) 1 3/8 (3.5 cm) 23 1/2 (59.7 cm) PRODUCT DIMENSIONS 1.3

9 DYO, DYOV Discovery iq 30 Wide Double Wall Ovens Revised 03/10/14 Cutout tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated. C 5 x 5 vent hole in back of cabinet recommended 52 1/8 (132.4 cm) min. to bottom of cabinet door * lternate electrical location (adjacent cabinet) 3/4 (1.9 cm) support platform 1 (2.5 cm) min. to top of drawer face Recommended electrical location 9 5/8 (24.4 cm) recommended 4 typical toe kick * 53 1/8 (134.9 cm) recommended () () (C) 30 (76.2 cm) 28 3/8 to 29 (72.1 cm to 73.7 cm) 50 1/4 to 50 3/4 (127.6 cm to cm) CUTOUT DIMENSIONS NOTES: 1. Minimum interior cabinet depth: 24 (61.0 cm). 2. 1/8 (3 mm) minimum clearance from appliance to adjacent cabinet doors/drawers. 1.4

10 DTO, DTOV Distinctive 27 and 30 Wide Single Wall Ovens Revised 10/10/14 Product tolerances: ±1/16 (±1.6 mm) unless otherwise stated J K Utility cutout Top of chassis F WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. G C H D Control panel front Control panel side view 3 1/2 (8.9 cm) 1 1/8 (2.9 cm) E 1 1/8 (2.9 cm) 3 3/16 (8.1 cm) Conduit: 60 (152 cm) long Top of chassis 1 1/8 (2.9 cm) Model DTO[V]127 DTO[V]130 (F) Utility Cutout Width 6 1/2 (16.5 cm) () Overall Width 26 7/8 (68.3 cm) 29 7/8 (75.9 cm) (G) Utility Cutout Height 5 (12.7 cm) () Chassis Width 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) (C) Overall Height 27 3/4 (70.5 cm) 27 3/4 (70.5 cm) (H) Utility Cutout Depth 7 7/8 (20.0 cm) 21 7/8 (55.6) cm (D)* Chassis Height 26 5/8 (67.6 cm) 26 5/8 (67.6 cm) (J) Control Panel Depth 1 1/4 (3.2 cm) (E) Control Panel Overlay 1 1/8 (2.9 cm) 1 1/8 (2.9 cm) (K) Chassis Depth 23 1/2 (59.7 cm) Epicure Millennia (Order kit #ROVH30S) Handle Dimensions Flush Model DTO[V]127 DTO[V]130 ELECTRICL SPECIFICTIONS Dedicated Circuit Requirements 240 Vac 60 Hz., 4-wire,*** 30 mp. 240 Vac 60 Hz., 4-wire,*** 30 mp. Total Connected Load 240 Vac 60 Hz, 23.3 mp., 5.6 kw 240 Vac 60 Hz, 24.9 mp., 6.0 kw *** Two 120 Vac hot (L1 and L2), one neutral, one ground The above specifications are for reference only. See the appliance data plate for exact specifications. 1.5

11 DTO, DTOV Distinctive 27 and 30 Wide Single Wall Ovens Revised 10/10/14 Cabinet/countertop tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated 1 (2.5 cm) min. to combustibles 1 1/2 (3.8 cm) typical counter 36 typ. (91.4 cm) P R Recommended electrical location 4 typical toe kick N 3/4 (1.9 cm) support platform 1 (2.5 cm) min. to combustible floor SINGLE WLL OVEN - INSTLLED UNDER COUNTER 1 (2.5 cm) min. to bottom of cabinet door Recommended electrical location Model Minimum Interior Cabinet Depth: 24 (61.0 cm) (N) Minimum Cabinet Width (P) Cut Out Width (R) Cutout Height P R 3/4 (1.9 cm) support platform DTO[V]127 DTO[V] (68.6 cm) 30 (76.2 cm) 25 5/8 (65.1 cm) minimum (recommended) 26 1/8 (66.4 cm) maximum 28 5/8 (72.7 cm) minimum (recommended) 29 1/8 (74.0 cm) maximum 26 3/4 (67.9 cm) minimum (recommended) 27 1/2 (69.9 cm) maximum 26 3/4 (67.9 cm) minimum (recommended) 27 1/2 (69.9 cm) maximum 1 (2.5 cm) min. to top of cabinet door lternate electrical location 31 1/4 (79.4 cm) recommended 4 typical toe kick SINGLE WLL OVEN - CUTOUT DIMENSIONS 1.6

12 DTO, DTOV Distinctive 27 and 30 Wide Double Wall Ovens Revised 10/10/14 Product tolerances: ±1/16 (±1.6 mm) unless otherwise stated J K Utility cutout Top of chassis F G WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. H C D 21 7/8 (55.6) cm Control panel front Control panel side view E Top of chassis Conduit: 60 (152 cm) long Model DTO[V]227 DTO[V]230 () Overall Width 26 7/8 (68.3 cm) 29 7/8 (75.9 cm) () Chassis Width 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) (C) Overall Height 50 1/8 (127.3 cm) 50 1/8 (127.3 cm) (D) Chassis Height 49 (124.5 cm) 49 (124.5 cm) (E) Control Panel Overlay 1 1/8 (2.9 cm) 1 1/8 (2.9 cm) 3 1/2 (8.9 cm) 1 1/8 (2.9 cm) 1 1/8 (2.9 cm) 3 3/16 (8.1 cm) 1 1/8 (2.9 cm) (F) Utility Cutout Width 6 1/2 (16.5 cm) (G) Utility Cutout Height 5 (12.7 cm) (H) Utility Cutout Depth 7 7/8 (20.0 cm) (J) Control Panel Depth 1 1/4 (3.2 cm) (K) Chassis Depth 23 1/2 (59.7 cm) Model DTO[V]227 DTO[V]230 ELECTRICL SPECIFICTIONS Dedicated Circuit Total Connected Load Requirements 240 Vac 60 Hz., 4-wire,* 40 mp. 240 Vac 60 Hz., 4-wire,* 40 mp. 240 Vac 60 Hz, 26.2 mp., 6.4 kw 240 Vac 60 Hz, 26.6 mp., 6.4 kw * Two 120 Vac hot (L1 and L2), one neutral, one ground Epicure Millennia (Order kit #ROVH30S) Flush The above specifications are for reference only. See the appliance data plate for exact specifications. Handle Dimensions 1.7

13 DTO, DTOV Distinctive 27 and 30 Wide Double Wall Ovens Revised 10/10/14 Cabinet/countertop tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated N 1 (2.5 cm) min. to bottom of cabinet door Recommended electrical location R P 3/4 (1.9 cm) support platform 1 (2.5 cm) min. to top of drawer face 4 typical toe kick 9 5/8 (24.4 cm) recommended Minimum Interior Cabinet Depth: 24 (61.0 cm) Model (N) Minimum Cabinet Width (P) Cut Out Width (R) Cutout Height DTO[V] (68.6 cm) 25 5/8 (65.1 cm) minimum (recommended) 26 1/8 (66.4 cm) maximum 49 1/8 (124.8 cm) minimum (recommended) 50 (127.0 cm) maximum DTO[V] (76.2 cm) 28 5/8 (72.7 cm) minimum (recommended) 29 1/8 (74.0 cm) maximum 49 1/8 (124.8 cm) minimum (recommended) 50 (127.0 cm) maximum 1.8

14 RNO, RNOV Renaissance 27 and 30 Wide Single Wall Ovens Revised 11/25/14 J Product tolerances: ±1/16 (±1.6 mm) unless otherwise stated K Utility cutout Top of chassis F G WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. 2 3/8 (6.0 cm) 1 7/8 (4.8 cm) C H D Control panel front Control panel side view L E M Conduit: 60 (152 cm) long Top of chassis Epicure Model RNO[V]127 RNO[V]130 Millennia (Order kit #ROVH30S) Handle Dimensions Flush ELECTRICL SPECIFICTIONS Dedicated Circuit Total Connected Load Requirements 240 Vac 60 Hz., 4-wire,*** 30 mp. 240 Vac 60 Hz., 4-wire,*** 30 mp. 240 Vac 60 Hz, 19.0 mp., 4.7 kw 240 Vac 60 Hz, 24.5 mp., 6.0 kw *** Two 120 Vac hot (L1 and L2), one neutral, one ground The above specifications are for reference only. See the appliance data plate for exact specifications. 21 1/2 (54.6) cm Model RNO[V]127 RNO[V]130 () Overall Width 26 7/8 (68.3 cm) 29 7/8 (75.9 cm) () Chassis Width 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) * To top of chassis notch behind control panel (C) Overall Height 27 3/4 (70.5 cm) 27 3/4 (70.5 cm) (D)* Chassis Height 27 3/8 (69.5 cm) 27 3/8 (69.5 cm) (E) Control Panel Overlay 3/8 (1.0 cm) 3/8 (1.0 cm) (F) Utility Cutout Width 6 1/2 (16.5 cm) (G) Utility Cutout Height 5 (12.7 cm) (H) Utility Cutout Depth 7 7/8 (20.0 cm) (J) Control Panel Depth 3/4 * (1.9 cm) (K) Chassis Depth 24 (61.0 cm) * 7/8 (2.2 cm) for models RNO[V]127, RNO[V]130, RNO127W and RNO130W (L) Control Panel Notch Depth 1/2 (1.3 cm) (M) Notch Height 3/4 (1.9 cm) 1.9

15 RNO, RNOV Renaissance 27 and 30 Wide, Single Wall Oven Revised 11/25/14 Cabinet tolerances: +1/16 (+1.6 mm) -0, unless otherwise stated 1 (2.5 cm) min. to combustibles 1 1/2 (3.8 cm) typical counter N 36 typ. (91.4 cm) P R Recommended electrical location 4 typical toe kick 1 (2.5 cm) min. to bottom of cabinet door Recommended electrical location 3/4 (1.9 cm) support platform 1 (2.5 cm) min. to combustible floor CUTOUT DIMENSIONS - STNDRD UNDER COUNTER INSTLLTION SINGLE WLL OVEN Minimum interior cabinet depth: 24 (61.0 cm) Model (N) Minimum Cabinet Width (P) Cutout Width (R) Minimum Cutout Height P R 3/4 (1.9 cm) support platform RNO[V]127 RNO[V] (68.6 cm) 30 (76.2 cm) 25 5/8 (65.1 cm) minimum (recommended) 26 1/8 (66.4 cm) maximum 28 5/8 (72.7 cm) minimum (recommended) 29 1/8 (74.0 cm) maximum 27 1/2 (69.9 cm) 27 1/2 (69.9 cm) 1 (2.5 cm) min. to top of cabinet door lternate electrical location 31 1/4 (79.4 cm) recommended 4 typical toe kick CUTOUT DIMENSIONS - STNDRD WLL INSTLLTION SINGLE WLL OVEN 1.10

16 RNO, RNOV Renaissance 27 and 30 Wide, Single Wall Oven Revised 11/25/14 CUTOUT DIMENSIONS - FLUSH INSTLLTION SINGLE WLL OVEN Cabinet tolerances: +1/16 (+1.6 mm) -0, unless otherwise stated T Finished stops * W TOP VIEW U V X VENTILTION INSET 3/4 (1.9 cm) SIDE VIEW Cabinet face 1 (2.5 cm) ** ** 1 1/8 (2.9 cm) for models RNO[V]127, RNO[V]130, RNO127W, RNO130W FRONT VIEW Model (T) Minimum Cabinet Depth (U) Cutout Width (V) Cutout Height (W) Stop Depth (X) Stop Width RNO127[F]S 24 3/4 (62.9 cm) 27 (68.6 cm) 27 7/8 (70.8 cm) 3/4 (1.9 cm) 3/8 (1.0 cm) RNO130[F]S 24 3/4 (62.9 cm) 30 (76.2 cm) 27 7/8 (70.8 cm) 3/4 (1.9 cm) 3/8 (1.0 cm) RNO[V]127, RNO127W 24 7/8 (63.2 cm) 27 (68.6 cm) 27 7/8 (70.8 cm) 7/8 (2.2 cm) 3/8 (1.0 cm) RNO[V]130, RNO130W 24 7/8 (63.2 cm) 30 (76.2 cm) 27 7/8 (70.8 cm) 7/8 (2.2 cm) 3/8 (1.0 cm) * ack of wall oven control panel rests against stops 1.11

17 RNO, RNOV Renaissance 27 and 30 Wide Double Wall Ovens Revised 01/13/15 Product tolerances: ±1/16 (±1.6 mm) unless otherwise stated J K Utility cutout Top of chassis F G WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. H C D 21 1/2 (54.6) cm Control panel front Control panel side view L E M Top of chassis Conduit: 60 (152 cm) long Model RNO[V]227 RNO[V]230 ELECTRICL SPECIFICTIONS Dedicated Circuit Total Connected Load Requirements 240 Vac 60 Hz., 4-wire,*** 40 mp. 240 Vac 60 Hz., 4-wire,*** 50 mp. 240 Vac 60 Hz, 39.4 mp., 9.5 kw 240 Vac 60 Hz, 48.6 mp., 12.0 kw *** Two 120 Vac hot (L1 and L2), one neutral, one ground The above specifications are for reference only. See the appliance data plate for exact specifications. Model RNO[V]227 RNO[V]230 () Overall Width 26 7/8 (68.3 cm) 29 7/8 (75.9 cm) () Chassis Width 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) * To top of chassis notch behind control panel (C) Overall Height 50 1/8 (127.3 cm) 50 1/8 (127.3 cm) (D)* Chassis Height 49 3/4 (126.4 cm) 49 3/4 (126.4 cm) (E) Control Panel Overlay 3/8 (1.0 cm) 3/8 (1.0 cm) (F) Utility Cutout Width (G) Utility Cutout Height (H) Utility Cutout Depth (J) Control Panel Depth (K) Chassis Depth (L) Control Panel Notch Depth (M) Notch Height 6 1/2 (16.5 cm) 5 (12.7 cm) 7 7/8 (20.0 cm) 3/4 (1.9 cm) 24 (61.0 cm) 1/2 (1.3 cm) 3/4 (1.9 cm) 1.12

18 RNO, RNOV Renaissance 27 and 30 Wide Double Wall Ovens Revised 01/13/15 N 2 3/8 (6.0 cm) 1 7/8 (4.8 cm) 1 (2.5 cm) min. to bottom of cabinet door Recommended electrical location Epicure Millennia (Order kit #ROVH30S) Flush R Handle Dimensions P 3/4 (1.9 cm) support platform 1 (2.5 cm) min. to top of drawer face 4 typical toe kick 9 5/8 (24.4 cm) recommended DOULE WLL OVEN - CUTOUT DIMENSIONS Model (N) Minimum Cabinet Width (P) Cut Out Width (R) Minimum Cutout Height RNO[V] (68.6 cm) 25 5/8 (65.1 cm) minimum (recommended) 26 1/8 (66.4 cm) maximum 49 7/8 (126.7 cm) RNO[V] (76.2 cm) 28 5/8 (72.7 cm) minimum (recommended) 29 1/8 (74.0 cm) maximum 49 7/8 (126.7 cm) Minimum interior cabinet depth: 24 (61.0 cm) 1.13

19 RNO, RNOV Renaissance 27 and 30 Wide, Double Wall Oven Revised 01/13/15 CUTOUT DIMENSIONS - FLUSH INSTLLTION DOULE WLL OVEN Cabinet tolerances: +1/16 (+1.6 mm) -0, unless otherwise stated T Finished stops * W TOP VIEW U X V VENTILTION INSET 3/4 (1.9 cm) SIDE VIEW Cabinet face 1 (2.5 cm) ** ** 1 1/8 (2.9 cm) for models RNO[V]227, RNO[V]230, RNO227W, RNO230W FRONT VIEW Model (T) Minimum Cabinet Depth (U) Cutout Width (V) Cutout Height (W) Stop Depth (X) Stop Width RNO227[F]S 24 3/4 (62.9 cm) 27 (68.6 cm) 50 1/4 (127.6 cm) 3/4 (1.9 cm) 3/8 (1.0 cm) RNO230[F]S 24 3/4 (62.9 cm) 30 (76.2 cm) 50 1/4 (127.6 cm) 3/4 (1.9 cm) 3/8 (1.0 cm) RNO[V]227, RNO227W 24 7/8 (63.2 cm) 27 (68.6 cm) 50 1/4 (127.6 cm) 7/8 (2.2 cm) 3/8 (1.0 cm) RNO[V]230, RNO230W 24 7/8 (63.2 cm) 30 (76.2 cm) 50 1/4 (127.6 cm) 7/8 (2.2 cm) 3/8 (1.0 cm) * ack of wall oven control panel rests against stops 1.14

20 DWD, ERWD, EWD, IWD, MRWD, MWDH, MWDV, OWD, RWDV 24, 27, 30, 36 Wide Warming Drawers Revised 01/18/12 Product tolerances: ±1/16 (±1.6 mm) unless otherwise stated DWD 1 (2.5 cm) 3 1/2 (8.9 cm) 1 1/8 (2.9 cm) ERWD 3 7/16 (8.7 cm) EWD 1 (2.5 cm) Electrical Circuit Required 120 Vac, 60 Hz, 15 mp. grounded, dedicated circuit 10 1/8 (25.7 cm) Total Connected Load Vac, 60 Hz. Minimum mbient Operating Temperature 32 F (0 C) 1 7/16 (3.7 cm) MRWD30 (only) ll other MRWD series 1 (2.5 cm) MWDH, MWDV, RWDV 3 1/4 (8.3 cm) 1 (2.5 cm) DRWER FCE DIMENSIONS (MWD SERIES SHOWN) HNDLE DIMENSIONS - SIDE VIEW Mounting hole 9 places 40 (101.6 cm) 3-prong 120 Vac power cord 1/2" (1.3 cm) 9" (22.9 cm) C 10" (25.4 cm) Chassis without drawer inserted Chassis 23 3/8 (59.4 cm) 1/2" (1.3 cm) CHSSIS DIMENSIONS Drawer open 5/64" (2 mm) OVERLL DIMENSIONS - TOP VIEW (EWD SERIES SHOWN) 23 13/16 (60.5 cm) Model () Drawer Face Width () Chassis Face Width (C) Chassis Width DWD30 30 (76.2 cm) 29 5/8 (75.2 cm) 28 1/4 (71.8 cm) ERWD27 27 (68.6 cm) 26 5/8 (67.6 cm) 25 1/4 (64.1 cm) ERWD30 30 (76.2 cm) 29 5/8 (75.2 cm) 28 1/4 (71.8 cm) EWD24 24 (61.0 cm) 23 5/8 (60.0 cm) 22 1/4 (56.5 cm) EWD27 27 (68.6 cm) 26 5/8 (67.6 cm) 25 1/4 (64.1 cm) EWD30 30 (76.2 cm) 29 5/8 (75.2 cm) 28 1/4 (71.8 cm) EWD36 36 (91.4 cm) 35 5/8 (90.5 cm) 34 1/4 (87.0 cm) MRWD /4 (67.9 cm) 26 5/8 (67.6 cm) 25 1/4 (64.1 cm) MRWD /4 (75.6 cm) 29 5/8 (75.2 cm) 28 1/4 (71.8 cm) MWDH27 27 (68.6 cm) 26 5/8 (67.6 cm) 25 1/4 (64.1 cm) MWDH30 30 (76.2 cm) 29 5/8 (75.2 cm) 28 1/4 (71.8 cm) MWDV27 27 (68.6 cm) 26 5/8 (67.6 cm) 25 1/4 (64.1 cm) MWDV30 30 (76.2 cm) 29 5/8 (75.2 cm) 28 1/4 (71.8 cm) RWDV30 30 (76.2 cm) 29 5/8 (75.2 cm) 28 1/4 (71.8 cm) WRMING DRWER OVERLL DIMENSIONS 2.1

21 DWD, ERWD, EWD, IWD, MRWD, MWDH, MWDV, OWD, RWDV 24, 27, 30, 36 Wide Warming Drawers Revised 01/18/12 Product tolerances: ±1/16 (±1.6 mm) unless otherwise stated C Electrical Circuit Required 120 Vac, 60 Hz, 15 mp. grounded, dedicated circuit Total Connected Load Vac, 60 Hz. Minimum mbient Operating Temperature 32 F (0 C) Chassis E 5/16 (8 mm) D Drawer open F DRWER FCE DIMENSIONS (IWD/OWD SERIES SHOWN) OVERLL DIMENSIONS - IWD/OWD SERIES TOP VIEW ** ** Mounting hole, 9 places 40" (101.6 cm) 3 prong 120 Vac power cord ** ** G Chassis without drawer installed ** = OWD24 mounting holes CHSSIS DIMENSIONS (IWD/OWD SHOWN) Model () Dimension Drawer Face Width () Dimension Chassis Width (C) Dimension Chassis Face Width (D) Dimension Drawer Face Height (E) Dimension Chassis Depth (F) Dimension Drawer Depth (G) Dimension Chassis Height IWD /16 (56.7 cm) 22 1/4 (56.5 cm) 22 3/8 (56.8 cm) IWD /16 (64.3 cm) 25 1/4 (64.1 cm) 25 3/8 (64.5 cm) IWD /16 (71.9 cm) 28 1/4 (71.8 cm) 28 3/8 (72.1 cm) 8 15/16 (22.7 cm) 23 3/8 (59.4 cm) 23 13/16 (60.5 cm) 9 1/16 (23.0 cm) OWD /2 (57.1 cm) 22 1/2 (57.1 cm) 22 1/2 (57.1 cm) 11 7/8 (30.2 cm) 20 (50.8 cm) 18 (45.7 cm) 11 7/8 (30.2 cm) 2.2

22 DWD, ERWD, EWD, IWD, MRWD, MWDH, MWDV, OWD, RWDV 24, 27, 30, 36 Wide Warming Drawers Revised 01/18/12 Cabinet/countertop tolerances: +1/16 (+1.6 mm), -0 unless otherwise stated 36" typ. Warming drawer (91.4 cm) Warming 120 Vac drawer electrical outlet 27"/30"/36" Dacor single wall oven Warming drawer Warming drawer 120 Vac elect. 120 Vac elect. D C D C 36" typ. (91.4 cm) C C 3/4" min.* (1.9 cm) D 3/4" min.* (1.9 cm) Cooktop WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. Mounting platform must be 3/4" (1.9 cm) thick and support 100 lbs. 1 1/2" (3.8 cm) Typical countertop Warming drawer C 120 Vac electrical outlet 3/4 min.* (1.9 cm) Toe kick 3/4" min.* (1.9 cm) Model () Cutout Width () Min. Width to djacent Doors/ Drawers (C) Cutout Height (D) Min. Vertical Gap etween Cutouts Min. Cutout Depth DWD /2 (72.4 cm) 30 1/4 (76.8 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* ERWD /2 (64.8 cm) 27 1/4 (69.2 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* ERWD /2 (72.4 cm) 30 1/4 (76.8 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* EWD /2 (57.2 cm) 24 1/4 (61.6 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* EWD /2 (64.8 cm) 27 1/4 (69.2 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* EWD /2 (72.4 cm) 30 1/4 (76.8 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* EWD36**** 34 1/2 (87.6 cm) 36 1/4 (92.1 cm)* 9 1/8 (23.2 cm) N IWD /2 (57.2 cm) ** 9 1/8 (23.2 cm) 1 1/16 (2.7 cm) IWD /2 (64.8 cm) ** 9 1/8 (23.2 cm) 1 1/16 (2.7 cm) 24 (61.0 cm) IWD /2 (72.4 cm) ** 9 1/8 (23.2 cm) 1 1/16 (2.7 cm) MRWD /2 (64.8 cm) 27 (68.6 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* MRWD /2 (72.4 cm) 30 (76.2 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* MWDH /2 (64.8 cm) 27 1/4 (69.2 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* MWDH /2 (72.4 cm) 30 1/4 (76.8 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* MWDV /2 (64.8 cm) 27 1/4 (69.2 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* MWDV /2 (72.4 cm) 30 1/4 (76.8 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* OWD24***** 22 5/8 (57.5 cm) 24 1/4 (61.6 cm)*** 11 15/16 (30.3 cm) N 20 1/8 (51.1 cm) RWDV /2 (72.4 cm) 30 1/4 (76.8 cm)* 9 1/8 (23.2 cm) 1 1/4 (3.2 cm)* 24 (61.0 cm) * are minimum spacing to allow for ventilation and avoid scraping on DWD, ERWD, EWD, MRWD, MWDH, MWDV and RWDV series models. ** On IWD series models or OWD24 without the optional front panel kit: The chassis and the drawer faceplate are smaller than the cutout. The custom front panel mounts to the drawer faceplate. The height and width of the custom front panel must exceed the appropriate cutout dimensions ( and C above) to cover the hole. llow 1/4" minimum additional space on the top, bottom and sides from the custom front panel edge to prevent scraping against adjacent doors, drawers and the countertop. *** OWD24 with optional factory front panel kit only. are minimum spacing shown to avoid scraping. Gap above and below cutout is 3/4 minimum. See ** above for OWD24 with custom front panel. **** Model EWD36 cannot be installed above or below another warming drawer (any type). ***** Model OWD24 cannot be installed above, below or adjacent to a wall oven or warming drawer (any type). 2.3

23 MET304, MET365-1 Discovery 30 and 36 Wide, Electric Cooktops Revised 10/20/14 Product tolerances: ±1/16 (±1.6 mm) unless otherwise noted 30 1/4" * (76.8 cm) 4 (10.2 cm) chassis height 3/16 (4.8 mm) WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. 21 1/4" * (54.0 cm) 19 3/8" (49.5 cm) 28 3/8" (72.1 cm) 36 1/4" * (92.1 cm) 4 (10.2 cm) chassis height 3/16 (4.8 mm) PRODUCT DIMENSIONS - MET /4" * (54.0 cm) 19 3/8" (49.5 cm) 34 3/8" (87.3 cm) PRODUCT DIMENSIONS - MET365-1 * For units with stainless steel trim, other units may be up to 1/8" less. Model No. Electrical Circuit Required Total Connected Load* MET Vac, 60 Hz, 40 mps. 6.9 kw (29 mps.) MET Vac, 60 Hz, 50 mps.* 9.6 kw (40 mps.) * For reference only, See the product data label on bottom of unit for exact specifications. ELECTRICL SUPPLY REQUIREMENTS Minimum Supply Wire Size Line and Ground Connections No. 8 WG NOTES: 1. The cooktop is supplied with a flexible, 48 inch long power conduit consisting of two (2) insulated hot lead conductors (L1 and L2) and one (1) insulated ground conductor. There is no neutral connection. ll leads are copper. The conduit is connected to the right corner of the cooktop. Do not connect the ground wire to neutral. 2. Tested in accordance with the latest edition of NSI Z21.1 and U.L. 858 Standard for household cooking appliances. 3. These cooktops are not approved for recessed installation. 3.1

24 MET304, MET365-1 Discovery 30 and 36 Wide, Electric Cooktops Revised 10/20/14 ll tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated llow a minimum of 6 inches (15.2 cm) clearance between the top of the countertop and any combustible surface below, including the upper edge of a drawer below the cooktop. Proper under-cabinet clearance is also required for the cooktop hold down brackets. When installing model MET365-1 and the bottom of the chassis is to be enclosed wall to wall, you must install Dacor ventilation duct kit TD323. Cooktop cutout in top of cabinet 6 (15.2 cm) min. clearance to combustible surfaces 7 3 / 4 X 4 3 / 8 ventilation cut-outs in enclosure floor Model () Minimum Under Counter Clearance (Width) MET304 MET /2 (77.5 cm) 36 1/2 (92.7 cm) 3 /4 1 1 / / 2 3 /4 UNDER COUNTER CLERNCE TOP VIEW VENTILTION CUTOUT Cabinets that are: () Overhead Clearances: ll Installations Directly above cooking surface 1 To left or right of cooking surface 1, 2 30 (76.2 cm) 18 (45.7 cm) Rear wall 6" (15.2 cm) min. from mounting surface to combustibles below cooktop chassis C Model MET304 MET365-1 (C) Cutout Width: Installations without Downdraft Vent 28 3/4 (73.0 cm) 34 3/4 (88.3 cm) 2 1/4 min. (5.7 cm) 19 3/4 (50.2 cm) 1 min. (2.5 cm) 6 (15.2 cm) min. to combustible, side wall, both sides COUNTERTOP CUTOUT (WITHOUT DOWNDRFT VENT) 3.2

25 MET304, MET365-1 Discovery 30 and 36 Wide, Electric Cooktops Revised 10/20/14 ll tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated. 3/8 min. (1.0 cm) flat countertop overhang required behind cutout Countertop 5/8 min. (1.6 cm) flat countertop overhang required behind cutout Countertop Stiffener ETT or MET series cooktop Stiffener ETT or MET series cooktop Cabinet face 3/8 min. (1.0 cm) space behind downdraft vent chassis to clear stiffener ERV or PRV series downdraft vent: Check downdraft vent specifications to determine proper fit Cabinet face 5/8 min. (1.6 cm) space behind downdraft vent chassis to clear stiffener RV series downdraft vent: Check downdraft vent dimensions/specifications to determine proper fit 4 5/8 (11.7 cm) 9 7/8 (25.1 cm) with CP3 blower installed Floor Floor ERV ND PRV SERIES DOWNDRFT VENT INSTLLTION SIDE VIEW RV SERIES DOWNDRFT VENT INSTLLTION SIDE VIEW E C F Rear wall D 19 3/4" (50.2 cm) Cabinet face 1" min. (2.5 cm) 6" (15.2 cm) min. from mounting surface to combustibles below cooktop chassis 6" min. (15.2 cm) 6" min. (15.2 cm) COUNTERTOP CUTOUT (WITH DOWNDRFT VENT) TOP VIEW Cabinets that are: Directly above cooking surface 1 To left or right of cooking surface 1, 2 COUNTERTOP CUTOUT (WITH DOWNDRFT VENT) ISO VIEW () Overhead Clearances: ll Installations 30 (76.2 cm) 18 (45.7 cm) Model/Configuration () Cooktop Cutout Width (C) Downdraft Vent Cutout Width (D) Total Cutout Depth (E) Downdraft Vent Cutout Depth (F) Minimum Rear Countertop Overhang MET304 cooktop with ERV30[15] or PRV30 downdraft vent 28 3/4 27 3/4 22 1/2 (57.2 cm) 2 3/4 (7.0 cm) 3/8 (1.0 cm) MET304 cooktop with RV30 downdraft vent (73.0 cm) (70.5 cm) 22 1/4 (56.5 cm) 2 1/2 (6.4 cm) 5/8 (1.6 cm) MET365-1 cooktop with ERV36[15] or PRV36 downdraft vent 34 3/4 33 3/4 22 1/2 (57.2 cm) 2 3/4 (7.0 cm) 3/8 (1.0 cm) MET365-1 cooktop with RV36 downdraft vent (88.3 cm) (85.7 cm) 22 1/4 (56.5 cm) 2 1/2 (6.4 cm) 5/8 (1.6 cm) 3.3

26 DECT304, DECT365 Distinctive 30 and 36 Wide, Electric Cooktops Revised 10/17/13 Product tolerances: ±1/16 (±1.6 mm) unless otherwise noted WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. 30 (76.2 cm) 21 (53.3 cm) 19 3/16 (48.8 cm) 28 5/8 (72.7 cm) 2 (5.18 cm) PRODUCT DIMENSIONS - DECT (91.4 cm) 21 (53.3 cm) 19-3/16 (48.8 cm) 2 (5.18 cm) 34 (86.3 cm) PRODUCT DIMENSIONS - DECT365 IMPORTNT: DECT series cooktops are not approved for installation with a downdraft vent. Model No. Electrical Circuit Required Total Connected Load* Minimum Supply Wire Size Line and Ground Connections DECT Vac, 60 Hz, 30 mps. 6.7 kw (28 mps.) No. 10 WG DECT Vac, 60 Hz, 40 mps. 9.4 kw (39 mps.) No. 8 WG * For reference only, See the product data label on bottom of unit for exact specifications. ELECTRICL SUPPLY REQUIREMENTS NOTES: 1. The cooktop is supplied with a flexible, 48 inch long power conduit consisting of two (2) insulated hot lead conductors (L1 and L2) and one (1) insulated ground conductor. There is no neutral connection. ll leads are copper. The conduit is connected to the right rear corner of the cooktop. Do not cut or lengthen the conduit. 2. These cooktops are not approved for recessed installation. 3.4

27 DECT304, DECT365 Distinctive 30 and 36 Wide, Electric Cooktops Revised 10/17/13 ll tolerances: +1/16 (+1.6 mm), -0 unless otherwise stated 1 1/2" (3.8 cm) min. clearance - Width of cut - Depth of cut 1 (2.5 cm) from edge of cutout to front of countertop Hole in cabinet floor for conduit routing: 3 1/2" (9 cm) deep x 2 1/2" (6.5 cm) wide See notes 1-1/4" (3.2 cm) Canadian 2-1/4" (5.7 cm) US COUNTERTOP CUTOUT IMPORTNT: Under the cooktop it is necessary to install a partition, spaced from the bottom of the appliance as shown. Wall covering cabinets, and countertop must withstand heat up to 200 F (93 C) H Install junction box so that it can be reached through the front of the cabinet CINET DIMENSIONS ND REQUIREMENTS CONDUIT OPENING Model () () (C) (D) (E) (F) (G) (H) DECT304 DECT /16 (72.9 cm) to 28 15/16 (73.5 cm) 34-1/16 (86,5 cm) to 34-5/16 (87.2 cm) 19-1/4 (49.0 cm) to 19-9/16 (49.7 cm) 19-1/4 (49.0 cm) to 19-9/16 (49.7 cm) 30 (76.2 cm) min. 36 (91.4 cm) min. 18 (45.7 cm) min height from countertop to nearest cabinet on either side of unit 30 (76.2 cm) min.* clearance from countertop to unprotected overhead surface 2 (5 cm) min. clearance from cutout to side wall on the left and right of the unit 13 (33 cm) depth of unprotected overhead 12 (31 cm) min. from bottom of countertop and adjacent cabinet (right side) * 24 (61 cm) min. clearance if bottom of wood or metal cabinets is protected by not less than 1/4 (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel (0.04 cm) stainless steel, or (0.06 cm) aluminum or (0.05cm) copper. 30 (76.2 cm) min. clearance between top of cooking platform and bottom of unprotected wood or metal cabinet. NOTES: 1. Chamfer all exposed edges of decorative laminate to prevent damage from chipping. 2. Radius corners of cutout and file to insure smooth edges and prevent corner cracking. Recommend 1/4 or 3/8 diameter drill In each corner. 3. Rough edges, inside corners which have not been rounded and forced fits can contribute to cracking of the countertop laminate. 4. This cooktop has been designed with wide tolerances of cut-out to cover possible replacement with other brands. Dacor recommends that you use the minimum cutout dimensions in the case of new Installation. 5. lways consult the countertop manufacturer for specific instructions. 6. Ensure the countertop is square and level and ensure no structural members interfere with space requirements. 7. The junction box, must be located where it will allow considerable slack in the conduit for serviceability. 8. For solid surface material installations such as Surel and Corian, consult with solid surface manufacturer to determine if heat reflective tape is required. 3.5

28 ETT304-1, ETT365-2 Renaissance 30 and 36 Wide, Electric Cooktops Revised 10/20/14 Product tolerances: ±1/16 (±1.6 mm) unless otherwise noted 30 1/4" * (76.8 cm) 4 (10.2 cm) chassis height 3/16 (4.8 mm) WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. 21 1/4" * (54.0 cm) 19 3/8" (49.5 cm) 28 3/8" (72.1 cm) 36 1/4" * (92.1 cm) 4 (10.2 cm) chassis height 3/16 (4.8 mm) PRODUCT DIMENSIONS - ETT /4" * (54.0 cm) 19 3/8" (49.5 cm) 34 3/8" (87.3 cm) PRODUCT DIMENSIONS - ETT365-2 * For units with stainless steel trim, other units may be up to 1/8" less. Model No. Electrical Circuit Required Total Connected Load* ETT Vac, 60 Hz, 40 mps. 6.9 kw (29 mps.) ETT Vac, 60 Hz, 40 mps. 9.1 kw (38 mps.) * For reference only, See the product data label on bottom of unit for exact specifications. ELECTRICL SUPPLY REQUIREMENTS Minimum Supply Wire Size Line and Ground Connections No. 8 WG NOTES: 1. The cooktop is supplied with a flexible, 48 inch long power conduit consisting of two (2) insulated hot lead conductors (L1 and L2) and one (1) insulated ground conductor. There is no neutral connection. ll leads are copper. The conduit is connected to the right corner of the cooktop. Do not connect the ground wire to neutral. 2. Tested in accordance with the latest edition of NSI Z21.1 and U.L. 858 Standard for household cooking appliances. 3. These cooktops are not approved for recessed installation. 3.6

29 ETT304-1, ETT365-2 Renaissance 30 and 36 Wide, Electric Cooktops Revised 10/20/14 ll tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated llow a minimum of 6 inches (15.2 cm) clearance between the top of the countertop and any combustible surface below, including the upper edge of a drawer below the cooktop. Proper under-cabinet clearance is also required for the cooktop hold down brackets. When installing model ETT365-2 and the bottom of the chassis is to be enclosed wall to wall, you must install Dacor ventilation duct kit TD323. Cooktop cutout in top of cabinet 6 (15.2 cm) min. clearance to combustible surfaces 7 3 / 4 X 4 3 / 8 ventilation cut-outs in enclosure floor Model () Minimum Under Counter Clearance (Width) ETT304-1 ETT /2 (77.5 cm) 36 1/2 (92.7 cm) 3 /4 1 1 / / 2 3 /4 UNDER COUNTER CLERNCE TOP VIEW VENTILTION CUTOUT Cabinets that are: () Overhead Clearances: ll Installations Directly above cooking surface 1 To left or right of cooking surface 1, 2 30 (76.2 cm) 18 (45.7 cm) Rear wall 6" (15.2 cm) min. from mounting surface to combustibles below cooktop chassis C Model (C) Cutout Width: Installations without Downdraft Vent 2 1/4 min. (5.7 cm) 19 3/4 (50.2 cm) ETT304-1 ETT /4 (73.0 cm) 34 3/4 (88.3 cm) 1 min. (2.5 cm) 6 (15.2 cm) min. to combustible, side wall, both sides COUNTERTOP CUTOUT (WITHOUT DOWNDRFT VENT) 3.7

30 ETT304-1, ETT365-2 Renaissance 30 and 36 Wide, Electric Cooktops Revised 10/20/14 ll tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated. 3/8 min. (1.0 cm) flat countertop overhang required behind cutout Countertop 5/8 min. (1.6 cm) flat countertop overhang required behind cutout Countertop Stiffener ETT or MET series cooktop Stiffener ETT or MET series cooktop Cabinet face 3/8 min. (1.0 cm) space behind downdraft vent chassis to clear stiffener ERV or PRV series downdraft vent: Check downdraft vent specifications to determine proper fit Cabinet face 5/8 min. (1.6 cm) space behind downdraft vent chassis to clear stiffener RV series downdraft vent: Check downdraft vent dimensions/specifications to determine proper fit 4 5/8 (11.7 cm) 9 7/8 (25.1 cm) with CP3 blower installed Floor Floor ERV ND PRV SERIES DOWNDRFT VENT INSTLLTION SIDE VIEW RV SERIES DOWNDRFT VENT INSTLLTION - SIDE VIEW E C F Rear wall D 19 3/4" (50.2 cm) Cabinet face 1" min. (2.5 cm) 6" (15.2 cm) min. from mounting surface to combustibles below cooktop chassis 6" min. (15.2 cm) 6" min. (15.2 cm) COUNTERTOP CUTOUT (WITH DOWNDRFT VENT) TOP VIEW Cabinets that are: Directly above cooking surface 1 To left or right of cooking surface 1, 2 COUNTERTOP CUTOUT (WITH DOWNDRFT VENT) ISO VIEW () Overhead Clearances: ll Installations 30 (76.2 cm) 18 (45.7 cm) Model/Configuration () Cooktop Cutout Width (C) Downdraft Vent Cutout Width (D) Total Cutout Depth (E) Downdraft Vent Cutout Depth (F) Minimum Rear Countertop Overhang ETT304-1 cooktop with ERV30[15] or PRV30 downdraft vent 28 3/4 27 3/4 22 1/2 (57.2 cm) 2 3/4 (7.0 cm) 3/8 (1.0 cm) ETT304-1 cooktop with RV30 downdraft vent (73.0 cm) (70.5 cm) 22 1/4 (56.5 cm) 2 1/2 (6.4 cm) 5/8 (1.6 cm) ETT365-2 cooktop with ERV36[15] or PRV36 downdraft vent 34 3/4 33 3/4 22 1/2 (57.2 cm) 2 3/4 (7.0 cm) 3/8 (1.0 cm) ETT365-2 cooktop with RV36 downdraft vent (88.3 cm) (85.7 cm) 22 1/4 (56.5 cm) 2 1/2 (6.4 cm) 5/8 (1.6 cm) 3.8

31 RNCT304, RNCT365 Renaissance 30 and 36 Wide, Electric Induction Cooktops Revised 10/20/14 WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. Product tolerances: ±1/16 (±1.6 mm) unless otherwise noted 30 2 (76.2 cm) Glass thickness: 3/16 (4.8 mm) 3 7/8 (9.8 cm) (48.3 cm) 1 (53.3 cm) 2 28 (72.4 cm) (91.4 cm) Glass thickness: 3/16 (4.8 mm) 3 7/8 (9.8 cm) PRODUCT DIMENSIONS - RNCT (48.3 cm) 1 2 (53.3 cm) 34 (86.4 cm) 1 PRODUCT DIMENSIONS - RNCT365 1 Chassis depth is 1/2 wider/deeper at base of glass cooking surface assembly. 2 Cooking surface overhangs top of chassis by 3/4 (1.9 cm) in front, back and on both sides. Model No. RNCT304 RNCT365 Total Connected Load* 31.0 mp kw 44.0 mp kw Dedicated Circuit Requirement 240 Vac, 60 Hz. 3 wire** 40 mp. 240 Vac, 60 Hz. 3 wire** 50 mp. * These specifications are for reference only. See the product data label for exact specifications. ** Two 120 Vac hot (L1 and L2) and one ground (all copper). ELECTRICL SUPPLY REQUIREMENTS 3.9

32 RNCT304, RNCT365 Renaissance 30 and 36 Wide, Electric Induction Cooktops Revised 10/20/14 Cabinet tolerances: +1/16 (+1.6 mm), -0 unless otherwise stated To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the cooktop should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood. Locate the junction box within reach of the included 48 inch long (122 cm) cooktop power conduit attached at the bottom right rear of the chassis. Make sure the underside of the cooktop and the junction box are accessible for inspection/service. To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly recommends installing a range hood. Install the range hood according to the accompanying installation instructions. range hood should cover the entire cooking surface below and project horizontally a minimum of 5 inches beyond the bottom of overhead cabinets. lways consult the countertop manufacturer for specific installation instruction or requirements. NOTE: The countertop opening must accept square corners of the cooktop. Some installations may require the installation of fire retardant materials (see notes below). Flame retardant materials bear the mark: UNDERWRITERS LORTORIES INC. CLSSIFIED MINERL ND FIER ORDS. SURFCE URNING CHRCTERISTICS This mark is followed by the flame spread and smoke ratings. These designations are shown as FHC (Flame Spread)/(Smoke Developed). Material with 0 flame spread rating are flame retardant. Local codes may allow other flame spread ratings. If the cooktop chassis is completely enclosed, provide ventilation of 7 square inches minimum into the enclosure. See following page for flush and downdraft vent installation cutouts. 13 (33.0 cm) max (45.7 cm) min. 3 Note 4 To allow for ventilation, maintain a minimum of 5 3/4 (14.6 cm) clearance between the top of the counter and NY surface below, including the upper edge of any drawers below. lso maintain a clearance of 2 (5.1 cm) between the vents on the front of the chassis and the cabinet. Countertop 19 3/4 (50.2 cm) 5 3/4 (14.6 cm) min. Non-combustible surface along back wall recommended Cooktop UNDER COUNTER CLERNCE Note 1 Note 5 Grate level 2 gap (5.1 cm) min. Front cabinet face 1 1/2 (3.8 cm) max. countertop thickness Note 2 CINET CUTOUT DIMENSIONS 1 30 inches minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet or = 24 inches minimum when the bottom of wood or metal cabinet is protected by not less than 1/4 inch thick flame retardant material covered with not less than #28 gage sheet steel,.015 inch thick stainless steel,.024 inch thick aluminum, or.020 inch thick copper. 2 Distance to combustible side wall (both sides): 2 7/8 (7.3 cm) min. from edge of cutout, 2 1/4 (5.7 cm) min. from edge of cooking surface. 3 This specification not applicable for cabinets more than a horizontal distance of 2 1/4 (5.7 cm) from edge of cooktop, when installed /8 (2.9 cm) min. to combustible surface to rear. 3/4 (1.9 cm) min. to non-combustible surface to rear. 5 Make sure proper internal spacing is maintained to allow for under-cabinet (chassis) ventilation. See diagram above. Model () () RNCT304 RNCT (76.2 cm) 36 (91.4 cm) 28 3/4 (73.0 cm) 34 3/4 (88.3 cm) 3.10

33 RNCT304, RNCT365 Renaissance 30 and 36 Wide, Electric Induction Cooktops Revised 10/20/14 Cabinet tolerances: +1/16 (+1.6 mm), -0 unless otherwise stated Countertop 3/16 (4.8 mm) 11/16 (7.0 mm) IMPORTNT: See previous page for minimum clearances to combustibles and overhead cabinets. Countertop Inset (side view) 19 3/4 (50.2 cm) Model () () RNCT304 RNCT /8 (76.5 cm) 36 1/8 (91.8 cm) 28 3/4 (73.0 cm) 34 3/4 (88.3 cm) 21 1/8 (53.7 cm) FLUSH INSTLLTION CUTOUT DIMENSIONS (COOKING SURFCE EVEN WITH COUNTERTOP) F D G IMPORTNT: See previous page for minimum clearances to combustibles and overhead cabinets. Install only the downdraft vent models specified in the table below. E 19 3/4" (50.2 cm) C Cabinet face If installing the cooktop and downdraft vent flush to the countertop, use the countertop inset dimensions shown above for the cooktop. The countertop inset for the downdraft vent will need to be lower to accommodate the top cap, which is different from model to model. Determine the inset depth from the product dimensions in the downdraft vent installation instructions. dditional sealing will be required between the cooktop chassis and the downdraft vent due to the difference in inset depth required. Model/Configuration (C) Cooktop Cutout Width (D) Vent Cutout Width (E) Total Cutout Depth (F) Vent Cutout Depth (G) Minimum Rear Countertop Overhang RNCT304 with ERV30[15]/PRV30 downdraft vent 28 3/4 27 3/4 22 1/2 (57.2 cm) 2 3/4 (7.0 cm) 3/8 (1.0 cm) RNCT304 with RV30 downdraft vent (73.0 cm) (70.5 cm) 22 1/4 (56.5 cm) 2 1/2 (6.4 cm) 5/8 (1.6 cm) RNCT365 with ERV36[15]/PRV36 downdraft vent 34 3/4 33 3/4 22 1/2 (57.2 cm) 2 3/4 (7.0 cm) 3/8 (1.0 cm) RNCT365 with RV36 downdraft vent (88.3 cm) (85.7 cm) 22 1/4 (56.5 cm) 2 1/2 (6.4 cm) 5/8 (1.6 cm) RNCT COOKTOP WITH DOWNDRFT VENT CUTOUT DIMENSIONS (TOP VIEW) 3.11

34 SGM304, SGM365, SGM466 Classic 30, 36 and 46 Wide, Drop-in Gas Cooktops Revised 10/20/14 ll tolerances ±1/16 (±1.6 mm), unless otherwise noted. WRNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. 30" (76.2 cm) 1 5/8" (4.1 cm) bottom of base to cooking surface 4" (10.2 cm) chassis height 21" (53.3 cm) 19 1/2" * (49.5 cm) * including embosses/screws in side of chassis 27 5/8" * (70.2 cm) 36" (91.4 cm) PRODUCT DIMENSIONS - MODEL SGM /8" (4.1 cm) bottom of base to cooking surface 4" (10.2 cm) chassis height 21" (53.3 cm) 19 1/2" * (49.5 cm) 33 1/2" * (85.1 cm) PRODUCT DIMENSIONS - MODEL SGM365 * including embosses in side of chassis 46" (116.8 cm) 4" (10.2 cm) chassis height 1 5/8" (4.1 cm) bottom of base to cooking surface 21" (53.3 cm) 19 1/2" * (49.5 cm) 44 5/8" * (113.3 cm) PRODUCT DIMENSIONS - MODEL SGM466 * including embosses/screws in side of chassis 4.1

35 SGM304, SGM365, SGM466 Classic 30, 36 and 46 Wide, Drop-in Gas Cooktops Revised 10/20/14 Electrical Requirements WRNING To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner s responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed. The cooktop is supplied with a factory installed, 40-inch, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis ottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician. The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code NSI/NFP 70* and local codes and ordinances. copy of this standard may be obtained from: National Fire Protection ssociation 1 atterymarch Park Quincy, Massachusetts The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference. e certain to locate the electrical outlet so that the power cord may be easily disconnected if the unit needs service. Front of unit Product data label Electric cord CHSSIS OTTOM DIGRM Gas inlet Gas Supply Requirements e certain that the cooktop being installed is correct for the gas service being provided (natural gas or LP gas). lso, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. Units equipped for LP operation have LP in the model number listed on the product data label. See the Chassis ottom Diagram for label location. Units equipped for high altitude operation have an H at the end of the model number listed on the product data label. Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code NSI Z223.1/NFP 54. n external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance. The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve. Models SGM304 and SGM365 come with a 1/2 regulator. Model SGM466 comes with a 3/4 regulator, approved for connection to a 1/2 house gas supply. The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis ottom Diagram on this page. SGM304 SGM365 SGM466 SGM304LP SGM365LP SGM466LP Gas type Natural LPG Manifold pressure Min. gas supply pressure** Max. gas supply pressure Total connected load Circuit requirement 4 Water column 10 Water column 5 Water column 11 Water column 1/2 psi 1/2 psi 0.25 mp. (0.03 kw) 120 Vac, 60 Hz, 15 mp mp. (0.03 kw) 120 Vac, 60 Hz, 15 mp. GS ND ELECTRICL REQUIREMENTS* * The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label. ** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure. 4.2

INSTALLATION INSTRUCTIONS ELECTRIC COOKTOP MODELS: CTE36P, CTE48P

INSTALLATION INSTRUCTIONS ELECTRIC COOKTOP MODELS: CTE36P, CTE48P 351 Thor Place rea, Ca 92821 (714) 482-2320 Fax (714) 482-2337 INSTLLTION INSTRUCTIONS ELECTRIC COOKTOP MODELS: CTE36P, CTE48P IMPORTNT: Save these instructions for Local Electrical Inspector s use. INSTLLER:

More information

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365 Distinctive Electric Cooktop Models DECT304, DECT365 Installation Instructions 105643 Rev. A Françis : voir page 11 Español: consulte la página 21 Table of Contents Page Special Warnings... Product Dimensions

More information

Distinctive TM Electric Cooktop

Distinctive TM Electric Cooktop Installation Instructions Distinctive TM Electric Cooktop Models DECT304, DECT365 _D PJ eo _o Lr) O Fran_:is voir page 1 1 Espa_ol: consuhe la p6gina 21 Table of Contents Page Special Warnings... 3 Product

More information

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV48

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV48 Document # PG08-001 Revised 02/28/14 Page 1/7 Dimensions - models ERV3015, ERV3615 5/16 (8 mm) thick stiffener across back 3 (7.6 cm) 1 15/16 (4.9 cm) 2 3/16 (5.6 cm) 2 1/8 (5.4 cm) 3/16 (5 mm) 2 9/16

More information

Installation Instructions Induction Cooktop

Installation Instructions Induction Cooktop Installation Instructions Induction Cooktop Models: RNCT304 and RNCT365 Part No. 107240 Rev. A Table of Contents Important Safety Instructions... 1 Important Information About Safety Instructions... 1

More information

Installation Instructions. Warming Drawer

Installation Instructions. Warming Drawer Warming Drawer Models: Installation Instructions ERWD30, EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MRWD27, MRWD30, MWDH27, MWDH30, MWDV27, MWDV30, OWD24, PWD27, PWD30 Part No. 102345 Rev. J All

More information

Installation Instructions. Warming Drawer. Preliminary - For Review Only

Installation Instructions. Warming Drawer. Preliminary - For Review Only Warming Drawer Models: Installation Instructions DWD30, ERWD27, ERWD30, EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MRWD27, MRWD30, MWDH27, MWDH30, MWDV27, MWDV30, OWD24, RWDV30 Preliminary - For

More information

Installation Instructions

Installation Instructions Installation Instructions Free-Standing Electric Ranges Questions? Call 800.GE.CRES (800.432.2737) or Visit our Website at: ge.com EFORE YOU EGIN Read these instructions completely and carefully. IMPORTNT

More information

Installation Instructions. Warming Drawer

Installation Instructions. Warming Drawer Warming Drawer Models: Installation Instructions ERWD30, EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MRWD27, MRWD30, MWDH27, MWDH30, MWDV27, MWDV30, OWD24, PWD27, PWD30 Part No. 102345 Rev. N All

More information

Installation Instructions

Installation Instructions Installation Instructions 30" ELECTRIC Downdraft Cooktop Modules selected at time of purchase IMPORTANT: Read and save these instructions. Part No. 208040 A 438589 Quick Reference Table of Contents: Pages

More information

Installation Instructions Millennia Cooktops

Installation Instructions Millennia Cooktops Installation Instructions Millennia Cooktops TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD COOKING APPLIANCES. IMPORTANT WARNINGS: IMPORTANT: NOTES: 1. Before beginning

More information

Installation Instructions Preference. Cooktop. Models: SGM304, SGM365, SGM466. Part No Rev. K

Installation Instructions Preference. Cooktop. Models: SGM304, SGM365, SGM466. Part No Rev. K Installation Instructions Preference Cooktop Models: SGM304, SGM365, SGM466 Part No. 65141 Rev. K Table of Contents Important Safety Instructions... 1 Important Information About Safety Instructions...

More information

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G PGM-1 Cooktops For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G Install ation Instructions Part No. 65476 Rev. B Table of Contents Appliance Safety...1 Important Safety Instructions...2

More information

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View Document # PG08-003 Revised 04/30/09 Page 1/7 1/2 (13 mm) thick stiffener across back 3 1/8" (79 mm) 2" (51 mm) 1 15/16" (49 mm) 1 13/16" (46 mm) 3/16" (5 mm) 2 5/16" (59 mm) Top cap with vent down 15/16"

More information

Installation Instructions

Installation Instructions Installation Instructions 30 Electric - Radiant Excludes Down-Draft Models If you have questions, call 800.GE.CARES or visit our website at: GEAppliances.com. In Canada, call 800.561.3344 or visit our

More information

Installation Instructions Wall Ovens

Installation Instructions Wall Ovens Installation Instructions Wall Ovens TESTED IN ACCORDANCE WITH THE LATEST EDITION OF UL858 STANDARD FOR HOUSEHOLD ELECTRIC COOKING APPLIANCES. IMPORTANT 1. Before beginning installation, please thoroughly

More information

Installation Instructions. Warming Drawer. Models: EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MWDV27, MWDH27, MWDV30, MWDH30 PWD27, PWD30

Installation Instructions. Warming Drawer. Models: EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MWDV27, MWDH27, MWDV30, MWDH30 PWD27, PWD30 Warming Drawer Models: EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MWDV27, MWDH27, MWDV30, MWDH30 PWD27, PWD30 Installation Instructions Part No. 102345 Rev. All specifications are subject to change

More information

Installation Instructions

Installation Instructions Installation Instructions 30 Electric Cooktop JP346, JP356, PP9, PP93, PP94, PP945, PP950 If you have questions, call 800.GE.CARES or visit our website at: ge.com BEFORE YOU BEGIN Read these instructions

More information

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING FOR YOUR SAFETY:

More information

Downdraft Raised Vent

Downdraft Raised Vent Downdraft Raised Vent Model ERV3615 Installation Instructions Use these downdraft raised vents only with approved Dacor appliances. See the installation instructions for the particular appliance model

More information

Installation Instructions Dual Fuel Ranges

Installation Instructions Dual Fuel Ranges Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you

More information

Integrated Ventilation System

Integrated Ventilation System Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Installation Instructions Part No. 65278 Rev. K Table of Contents Important Safety Instructions... 1 Important Information About

More information

Electric Built-in Ceramic Cooktops

Electric Built-in Ceramic Cooktops 30 and 36 Electric Built-in Ceramic Cooktops Read and save these instructions. nstaller: Leave nstallation nstructions with the homeowner. Homeowner: Keep nstallation nstructions for future reference.

More information

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down Document # PG08-004 Revised 02/06/13 Page 1/5 Renaissance 30, 36 Wide, 5/16 (8 mm) thick stiffener across back 3 (7.6 cm) 1 15/16 (4.9 cm) 2 3/16 (5.6 cm) 2 1/8 (5.4 cm) 3/16 (5 mm) 2 9/16 (6.5 cm) Vent

More information

Installation Instructions Remote Blowers

Installation Instructions Remote Blowers Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor hood assembly or

More information

Installation Instructions Distinctive. Series Cooktop. Models DCT305, DCT365. Part No Rev. L

Installation Instructions Distinctive. Series Cooktop. Models DCT305, DCT365. Part No Rev. L Installation Instructions Distinctive Series Cooktop Models DCT305, DCT365 Part No. 106927 Rev. L Table of Contents Important Safety Instructions... 1 Important Information About Safety Instructions...

More information

INSTALLATION INSTRUCTIONS MANUAL STEEL GAS STAR COOKTOPS 30" MODELS: SGS304, SGSX304 36" MODELS: SGS365, SGSX365 45" MODELS: SGS456, SGSX456

INSTALLATION INSTRUCTIONS MANUAL STEEL GAS STAR COOKTOPS 30 MODELS: SGS304, SGSX304 36 MODELS: SGS365, SGSX365 45 MODELS: SGS456, SGSX456 INSTALLATION INSTRUCTIONS MANUAL STEEL GAS STAR COOKTOPS 30" MODELS: SGS304, SGSX304 36" MODELS: SGS365, SGSX365 45" MODELS: SGS456, SGSX456 PLEASE READ INSTRUCTION BEFORE PROCEEDING IMPORTANT: INSTALLER:

More information

Built-In Cooktops FGEC3067M S/B. 30" Electric. Signature Features. More Easy-To-Use Features. Product Dimensions

Built-In Cooktops FGEC3067M S/B. 30 Electric. Signature Features. More Easy-To-Use Features. Product Dimensions Width 30-3/8" Depth 21-3/8" Height 2-5/8" More Easy-To-Use Features Fits-More Cooktop The Fits-More cooktop features five elements so you can cook more at once. Ceramic Glass Cooktop For a more beautiful

More information

Installation Instructions

Installation Instructions NEM73 NEM93 Bosch Glass Ceramic Cooktops Table of Contents NOTE: The blocked letters, such as A, shown below, refer to illustrations on Pages 2 & 4. Match these to the related text pages. Overall Dimensions

More information

Installation Instructions Epicure. Cooktop. Models: ESG366, ESG486. Part No Rev. K

Installation Instructions Epicure. Cooktop. Models: ESG366, ESG486. Part No Rev. K Installation Instructions Epicure Cooktop Models: ESG366, ESG486 Part No. 65162 Rev. K Table of Contents Important Safety Instructions... 1 Important Information About Safety Instructions... 1 General

More information

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm)

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS 24 (61.0 cm), 27 (68.6 cm), 30 (76.2 cm) BUILT-IN MICROWVE OVEN INSTLLTION INSTRUCTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm) This product is suitable for use above electric or gas built-in ovens, and below non-vented electric or gas cooktops.

More information

Table of Contents/Table des matières COOKTOP SAFETY

Table of Contents/Table des matières COOKTOP SAFETY 30" (76.2 M) ELETRI INDUTION OOKTOP INSTLLTION INSTRUTIONS INSTRUTIONS D'INSTLLTION DE LTLEDEUISSON ÉLETRIQUE À INDUTION DE 30" (76,2 M) Table of ontents/table des matières OOKTOP SFETY... 1 INSTLLTION

More information

Installation Instructions

Installation Instructions Installation Instructions 30 Electric Cooktop JP340, JP350, JP930, JP93, JP938, JP939 If you have questions, call 800.GE.CARES or visit our website at: www.geappliances.com BEFORE YOU BEGIN Read these

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Drop-In Range JDS28, JDP39 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN Read these instructions carefully and completely.

More information

Ins t a l l a t i o n In s t r u c t i o n s Wa r m i n g Ov e n For use with models: EW, EWO MW, MWO PW, PWO IWO, IOWO

Ins t a l l a t i o n In s t r u c t i o n s Wa r m i n g Ov e n For use with models: EW, EWO MW, MWO PW, PWO IWO, IOWO Ins t a l l a t i o n In s t r u c t i o n s Wa r m i n g Ov e n For use with models: EW, EWO MW, MWO PW, PWO IWO, IOWO Part No. 65034 Rev. K Important Safety Instructions...1 Design Specifications...2-3

More information

Installation Instructions

Installation Instructions Installation Instructions Discovery Touch-Control Induction Cooktop Models DYTT305N, DYTT365N, HICT305BG, HICT365BG Part No. 109374 Rev. E Important Safety Instructions... 1 Important Information About

More information

gas cooktops EW30GC55P S / B

gas cooktops EW30GC55P S / B Product Dimensions Width Depth 2-3/4" Height (Extreme Bottom to Underside of Cooktop) 4-/4" More Easy-To-Use Features SEALED BURNERS Electric Pilotless Ignition Platinum Star Limited Warranty Our exclusive

More information

130"ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded.

130ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded. I Iinstallation 130"ElectricCooktop nstructlons _,0, JP355, JP910, JP930, JP940, JP950 I r_ www.geappliances.com",,if you have questions, call 800.GE.CARES or visit our website at: I BEFORE YOU BEGIN MATERIALS

More information

Built-In Cooktop FGEC3045PS. 30" Electric. Signature Features. More Easy-To-Use Features. Product Dimensions

Built-In Cooktop FGEC3045PS. 30 Electric. Signature Features. More Easy-To-Use Features. Product Dimensions Width 30-3/8" Depth 21-3/8" Height 2-5/8" More Easy-To-Use Features Approved Over Frigidaire Electric Wall Ovens Cooktops are approved for installation above any of our Single Electric Wall Ovens. Available

More information

Installation Instructions. Discovery Gas Cooktop. Models DYCT304G, DYCT365G. Part No Rev. A

Installation Instructions. Discovery Gas Cooktop. Models DYCT304G, DYCT365G. Part No Rev. A Discovery Gas Cooktop Models DYCT304G, DYCT365G Installation Instructions Part No. 108861 Rev. A Important Safety Instructions...1 Important Information About Safety Instructions...1 General Safety Precautions...2

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS CLASSIC WALL OVENS FOR MODELS: ECD227, ECD230, ECS127, ECS130, ECS136, ECS227, ECS230, MCD227, MCD230, MCS127, MCS130 MCS227, MCS230, PCD230, PCS130, PCS230 Part No 65030 Rev

More information

SAVE AND READ THESE INSTRUCTIONS

SAVE AND READ THESE INSTRUCTIONS Installation Instructions Epicure Outdoor Grill SAVE AND READ THESE INSTRUCTIONS TESTED IN ACCORDANCE ITH THE LATEST EDITION OF ANSI Z21.58-1998, CGA 1.6-M98 STANDARD FOR OUTDOOR GAS COOKING APPLIANCES.

More information

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING FOR YOUR SAFETY:

More information

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR

More information

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 36" Stainless Steel Gas Cooktops Natural Gas Model: ZGU375NS LP Gas Model ZGU375LS Monogram.

More information

Built-In Cooktops FGEC3645K S/W/B. 36" Electric. Signature Features. More Easy-To-Use Features. Product Dimensions. Hot Surface Indicators

Built-In Cooktops FGEC3645K S/W/B. 36 Electric. Signature Features. More Easy-To-Use Features. Product Dimensions. Hot Surface Indicators Width 36-3/4" Depth 21-3/8" Height 2-5/8" More Easy-To-Use Features Hot Surface Indicators Smoothtop Ceramic Glass Cooking Surface Available in: Stainless (S) White (W) Black (B) Elements Right Front Right

More information

PCG305P 30-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE

PCG305P 30-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE FEATURES & BENEFITS - Patented Pedestal Star Burner with QuickClean Base designed for easy surface cleaning and superior heat spread for any size pan - Precision simmering capabilities as low as 100 F

More information

Installation Instructions. Discovery Wall Oven. EO, MOH and MOV Series. Part No Rev. M

Installation Instructions. Discovery Wall Oven. EO, MOH and MOV Series. Part No Rev. M Discovery Wall Oven EO, MOH and MOV Series Installation Instructions Part No. 65433 Rev. M All specifications are subject to change without notice. Dacor assumes no liability for changes to specifications.

More information

Approved Over Frigidaire Electric Wall Ovens. Cooktops are approved for installation above any of our Electric Single Wall Ovens.

Approved Over Frigidaire Electric Wall Ovens. Cooktops are approved for installation above any of our Electric Single Wall Ovens. Width 30-3/4" Depth 21-3/8" Height 3" Available in: Black (B) Elements Right Front Right Rear Left Front Left Rear Size 9" 6" 6" 9" Watts 2,500 1,200 1,200 2,500 Signature Features Ready-Select Controls

More information

Installation Instructions

Installation Instructions Installation Instructions Self-Cleaning Radiant Electric Drop-In Range JDP47, JD968, JD900 If you have questions, call 1.800.GE.CARES or visit our website at: ge.com Before You Begin Read these instructions

More information

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y GE Monogram Installation Instructions Component Cooktop System Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y Before you begin Read these instructions completely and carefully. IMPORTANT: Save

More information

136"ElectricCooktop. nstructlons. I Iinstallation. -&WARNING - This appliance must be properly grounded.

136ElectricCooktop. nstructlons. I Iinstallation. -&WARNING - This appliance must be properly grounded. nstructlons I Iinstallation 136"ElectricCooktop I =_ www.g If you have EAp plia questions, nces.co m" call 800.GE.CARES or visit our website at: BEFORE YOU BEGIN MATERIALS YOU WILL NEED Read these instructions

More information

Table of Contents/ Table des matières

Table of Contents/ Table des matières 30" (76.2 M) ND 36" (91.4 M) ELETRI INDUTION OOKTOP INSTLLTION INSTRUTIONS INSTRUTIONS D INSTLLTION DE L TLE DE UISSON ÉLETRIQUE À INDUTION DE 30" (76,2 M) ET DE 36" (91,4 M) OOKTOP SFETY... 2 INSTLLTION

More information

Installation Instructions Renaissance. Rangetop. Models: EG366, EG486

Installation Instructions Renaissance. Rangetop. Models: EG366, EG486 Installation Instructions Renaissance Models: EG366, EG486 Rangetop THIS APPLIANCE HAS EEN TESTED IN ACCORDANCE ITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES. Part No. 102025

More information

Drop-In Built-In Cooktops

Drop-In Built-In Cooktops Drop-In Built-In Cooktops FPEC3085K FFEC3624P S / W/ B 30" 36" Electric Width 36-3/4" Depth 21-3/8" Height 3" More Easy-To-Use Features On Indicator Alerts you when your cooktop is on. Available in: Stainless

More information

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING By CNP INDUSTRIES, INC. P.O. Box 18645 Anaheim, Ca 92817 (877) 387-6721 INSTALLATION INSTRUCTIONS GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D IMPORTANT: Before beginning installation please read these

More information

15" (38.1 CM) ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DE TABLE DE CUISSON ÉLECTRIQUE DE 15" (38,1 CM)

15 (38.1 CM) ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DE TABLE DE CUISSON ÉLECTRIQUE DE 15 (38,1 CM) 15" (38.1 M) LTRI OOKTOP INSTLLTION INSTRUTIONS INSTRUTIONS INSTLLTION TL UISSON ÉLTRIQU 15" (38,1 M) Table of ontents/table des matières OOKTOP STY...2 INSTLLTION RQUIRMNTS...3 Tools and Parts...3 Location

More information

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed Table of Contents 1 Installation 6 1.1 General installation instructions 6 1.2 Electrical requirements 7 1.3 Electrical connection 8 1.4 Cable replacement 10 1.5 Positioning 10 EN Important Safety Instructions

More information

Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models EO, MO and PO

Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models EO, MO and PO Discovery Wall Oven For use with models EO, MO and PO Installation Instructions Preliminary - For Review Only No Scheduled Release Date Part No. 65433 Rev. H All specifications are subject to change without

More information

GE Monogram 36" Induction Cooktop

GE Monogram 36 Induction Cooktop Monogram 36" Induction ooktop OVRLL IMNSIONS 1 1/16" (2.7) utout overlap 36" (91.4) 33 7/8" (86.0) utout width 5/8" (1.6) utout overlap SPIITIONS Overall Width Overall epth 36" (91.4 cm) 20 3/8" (51.8

More information

Installation Instructions. Discovery Rangetop. Models: DYRTP366, DYRTP486, HRTP366, HRTP486

Installation Instructions. Discovery Rangetop. Models: DYRTP366, DYRTP486, HRTP366, HRTP486 Discovery Rangetop Models: DYRTP366, DYRTP486, HRTP366, HRTP486 Installation Instructions THIS APPLIANCE HAS EEN TESTED IN ACCORDANCE ITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES.

More information

Installation Instructions

Installation Instructions Installation Instructions Downdraft Vent Systems PVB94 PVB98 ZVB30 ZVB36 31-10728-8 11-14 GE 1 Safety Information If you have questions, call 800.GE.CARES or visit our website at: GEAppliances.com BEFORE

More information

Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models: EO, MO and PO

Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models: EO, MO and PO Discovery Wall Oven For use with models: EO, MO and PO Installation Instructions Preliminary - For Review Only No Scheduled Release Date Part No. 65433 Rev. G All specifications are subject to change without

More information

Quick Reference. Table of Contents: ff you need assistance:

Quick Reference. Table of Contents: ff you need assistance: Quick Reference Table of Contents: Pages [] Product dimensions [] Cabinet opening dimensions [] Before you start [] Electrical requirements [] [] Installation steps ff you need assistance: Check your Use

More information

Even Baking Technology. Our latest technology ensures even baking every time. Hi /Lo Broil Option

Even Baking Technology. Our latest technology ensures even baking every time. Hi /Lo Broil Option Drop-In Freestanding Cooktop Ranges FPEC3085K FFEF3011L W/ S B Product Dimensions Height (Max.) 47-1/2" Width 29-7/8" Depth (Including Handle) 28-1/2" More Easy-To-Use Features Oven Door with Large Window

More information

PRL305PH 30-INCH GAS PRO HARMONY RANGE (LP) PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

PRL305PH 30-INCH GAS PRO HARMONY RANGE (LP) PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE Also Available: PRG305PH - Natural Gas FEATURES & BENEFITS - Exclusive, patented Star Burner most even heating, unsurpassed flame coverage - QuickClean Base designed for easy surface cleaning - Precision

More information

Distinctive Series Cooktop

Distinctive Series Cooktop Distinctive Series Cooktop Models: DRT304S, DRT366S Installation Instructions THIS APPLIANCE HAS EEN TESTED IN ACCORDANCE ITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES. Part

More information

Multi-Function Cooktop

Multi-Function Cooktop INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............

More information

PRL486GDH 48-INCH GAS PRO HARMONY RANGE WITH GRIDDLE (LP) PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

PRL486GDH 48-INCH GAS PRO HARMONY RANGE WITH GRIDDLE (LP) PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE Also Available: PRG486GDH - Natural Gas FEATURES & BENEFITS - Exclusive, patented Star Burner most even heating, unsurpassed flame coverage - QuickClean Base designed for easy surface cleaning - Precision

More information

Installation Instructions

Installation Instructions Installation Instructions Important Save for local electrical inspector s use. Electric Cooktop Keep instructions for future reference. Be sure manual stays with cooktop. Read entire instruction and Owner

More information

PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE GENERAL PROPERTIES. Sealed Burners

PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE GENERAL PROPERTIES. Sealed Burners FEATURES & BENEFITS - Patented Pedestal Star Burner with QuickClean Base designed for easy surface cleaning and superior heat spread for any size pan - Precision simmering capabilities as low as 100 F

More information

Modernist Warming Drawer

Modernist Warming Drawer Modernist Warming Drawer DWR30M977WS, DWR30M977WM Installation Instructions Part No. 110143 Rev B Contents Before you begin... 3 Important 3 Contents Customer-service information 4 If You Need Help...

More information

PRG486JDG 48-INCH GAS PRO GRAND RANGE WITH GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRG486JDG 48-INCH GAS PRO GRAND RANGE WITH GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE Also Available: PRL486JDG - LP FEATURES & BENEFITS - Patented Pedestal Star Burner with QuickClean Base designed for easy surface cleaning and superior heat spread for any size pan - Powerful 22,000 BTU

More information

PRG364JDG 36-INCH GAS PRO GRAND RANGE WITH GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRG364JDG 36-INCH GAS PRO GRAND RANGE WITH GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE Also Available: PRL364JDG - LP FEATURES & BENEFITS - Patented Pedestal Star Burner with QuickClean Base designed for easy surface cleaning and superior heat spread for any size pan - Powerful 22,000 BTU

More information

136"ElectricCooktop. nstructlons _,00, JP961, JP968, JP969, ZEU769. I Iinstallation. -&WARNING - This appliance must be properly grounded.

136ElectricCooktop. nstructlons _,00, JP961, JP968, JP969, ZEU769. I Iinstallation. -&WARNING - This appliance must be properly grounded. I Iinstallation 136"ElectricCooktop nstructlons _,00, JP961, JP968, JP969, ZEU769 I "?-I www.g "If you have EAp plia questions, nces.co m" call 800.GE.CARES or visit our website at: BEFORE YOU BEGIN MATERIALS

More information

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U Freestanding Electric Range Household Appliances 2U Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U PLEASE READ ENTIRE INSTRUCTIONS BEFORE

More information

Large Capacity. Our large capacity oven gives you room to cook more at once. SpaceWise Expandable Element

Large Capacity. Our large capacity oven gives you room to cook more at once. SpaceWise Expandable Element Drop-In Freestanding Cooktop Range FPEC3085K FFEF3048L S 30" Electric Product Dimensions Height (Max.) 47-1/2" Width 29-7/8" Depth (Including Handle) 28-1/2" More Easy-To-Use Features Extra-Large Element

More information

GAS COOKTOP INSTALLATION INSTRUCTIONS

GAS COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING If the information

More information

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions 30 French Door Built-in Wall Ovens Installation Instructions 30 French Door Built-in Wall Ovens Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.geappliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca DESIGN

More information

Express-Select Controls Easily go from warm to boil.

Express-Select Controls Easily go from warm to boil. Width 30" Depth 21-3/4" Height 5" More Easy-To-Use Features Stainless Steel Recessed Cooktop 1 Electronic Pilotless Ignition LP Gas Conversion Option Available in: Stainless (S) White (W) Black (B) Signature

More information

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not

More information

Installation Instructions. Renaissance Range

Installation Instructions. Renaissance Range Renaissance Range For use with models ER30D, ER30D-C, ER30DSR THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS COOKING APPLIANCES. Part No.

More information

FPEC3085K FFEF3015L S / M / W/ B

FPEC3085K FFEF3015L S / M / W/ B Drop-In Freestanding Cooktop Ranges FPEC3085K FFEF3015L S / M / W/ B Product Dimensions Height (Max.) 47-1/2" Width 29-7/8" Depth (Including Handle) 28-1/2" More Easy-To-Use Features Store-More Storage

More information

One of the more popular models of the Integrated

One of the more popular models of the Integrated ll Refrigerator Drawers Seamless molding Removable crisper cover Location of serial number Electronic digital control panel Magnetic drawer gaskets Upper refrigerator storage drawer Front venting with

More information

INSTALLATION INSTRUCTIONS 30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

INSTALLATION INSTRUCTIONS 30 (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN INSTLLTION INSTRUTIONS 30" (76.2 M) LTRI SINGL N OUL UILT-IN OVN Table of ontents UILT-IN OVN SFTY...2 INSTLLTION RQUIRMNTS...3 Tools and Parts...3 uilt-in Oven Location Requirements...3 Water Filtration

More information

PCG364WD 36-INCH GAS RANGETOP WITH GRIDDLE PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE GENERAL PROPERTIES. Sealed Burners

PCG364WD 36-INCH GAS RANGETOP WITH GRIDDLE PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE GENERAL PROPERTIES. Sealed Burners FEATURES & BENEFITS - Patented Pedestal Star Burner with QuickClean Base designed for easy surface cleaning and superior heat spread for any size pan - Precision simmering capabilities as low as 100 F

More information

Built-In Cooktops FGGC3665K S/W/B. 36" Gas. Signature Features. More Easy-To-Use Features. Product Dimensions

Built-In Cooktops FGGC3665K S/W/B. 36 Gas. Signature Features. More Easy-To-Use Features. Product Dimensions Width 36" Depth 21-1/2" Height 4-5/8" More Easy-To-Use Features Ceramic Glass Cooktop For a more beautiful cooktop that s easy to clean. Approved Over Frigidaire Electric Wall Ovens Cooktops are approved

More information

MODEL SHOWN: PCG486GD 48-INCH RANGETOP

MODEL SHOWN: PCG486GD 48-INCH RANGETOP 58 MODEL SHOWN: PCG486GD 48-INCH RANGETOP RANGETOPS PROFESSIONAL SERIES Thermador Professional Series Gas Rangetops set a new standard in performance and convenience. Thanks to the power of our fourth

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS INSTLLTION INSTRUCTIONS HOOD MODELS WSX, WCX, & WEX 35 Thor Place rea, Ca 98 (877) 387-67 IMPORTNT SFETY INSTRUCTIONS PLESE RED ENTIRE INSTRUCTION EFORE PROCEEDING. INSTLLTIONS MUST COMPLY WITH LL LOCL

More information

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and CAUTION symbols.

More information

Consider using this two drawer unit in conjunction

Consider using this two drawer unit in conjunction Freezer Drawers Seamless molding Location of serial number Electronic digital control panel Model 700BF Magnetic drawer gaskets Upper freezer storage drawer utomatic ice maker (Model 700BFI) Model 700BFI

More information

The Integrated line of refrigeration is growing literally

The Integrated line of refrigeration is growing literally Over-and-Under Refrigerator / Freezer Electronic digital control panel Seamless molding djustable spill-proof glass shelves djustable dairy compartment Egg container djustable door shelves Model 736TC

More information

2 PREPARE THE OPENING

2 PREPARE THE OPENING Installation Instructions 27 & 30 Electric Built-In Wall Ovens Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.geappliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca

More information

Service Manual Electric Cooktop

Service Manual Electric Cooktop Service Manual Electric Cooktop 318 202 105 (0311) THIS IS A BLANK PAGE Table of Contents I SAFE SERVICING PRACTICES... 1 PRODUCT FEATURES... 2 WIRING DIAGRAM... 3 SECTION A - INSTALLATION... 4 CUT-OUT

More information

PRG486GDH 48-INCH GAS PRO HARMONY RANGE WITH GRIDDLE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

PRG486GDH 48-INCH GAS PRO HARMONY RANGE WITH GRIDDLE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE Also Available: PRL486GDH - LP FEATURES & BENEFITS - Exclusive, patented Star Burner most even heating, unsurpassed flame coverage - QuickClean Base designed for easy surface cleaning - Precision simmering

More information

PowerPlus FullRange Burner Go from a 500-BTU simmer to a 17,000-BTU boil quickly.

PowerPlus FullRange Burner Go from a 500-BTU simmer to a 17,000-BTU boil quickly. Width 36" Depth 21-3/4" Height 4-1/4" More Easy-To-Use Features Heavy-Duty Grates and Professional-Style Knobs Low Simmer Burner Perfect for delicate foods and sauces. Fits-More Cooktop The Fits-More cooktop

More information

Quick Preheat Preheat in less than six minutes. 1

Quick Preheat Preheat in less than six minutes. 1 Slide-In Ranges FGDS3065K F/ W/ B 30" Dual-Fuel Product Dimensions Height (Max.) 36-5/8" Width 30" Depth 28-5/16" More Easy-To-Use Features Express-Select Controls Easily go from warm to boil. One-Touch

More information

PowerPlus FullRange Burner Go from a 500-BTU simmer to a 17,000-BTU boil quickly.

PowerPlus FullRange Burner Go from a 500-BTU simmer to a 17,000-BTU boil quickly. Width 36" Depth 21-3/4" Height 4-1/4" More Easy-To-Use Features Heavy-Duty Grates and Professional-Style Knobs Low Simmer Burner Perfect for delicate foods and sauces. Fits-More Cooktop The Fits-More cooktop

More information

SpaceWise Expandable Element. Flexible element expands to your cooking needs. Extra-Large Window

SpaceWise Expandable Element. Flexible element expands to your cooking needs. Extra-Large Window Drop-In Freestanding Cooktop Range FPEC3085K FFEF3043L S 30" Electric Product Dimensions Height (Max.) 47-1/2" Width 29-7/8" Depth (Including Handle) 28-1/2" More Easy-To-Use Features Hi /Lo Broil Option

More information

PRD305PH 30-INCH DUAL-FUEL PRO HARMONY RANGE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

PRD305PH 30-INCH DUAL-FUEL PRO HARMONY RANGE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE FEATURES & BENEFITS - Exclusive, patented Star Burner most even heating, unsurpassed flame coverage - QuickClean Base designed for easy surface cleaning - Precision simmering capabilities as low as 100

More information