Hydronic Mechanical Panels
|
|
- Quentin Lawrence
- 5 years ago
- Views:
Transcription
1 Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont Phone : Hydronic Assemblies Inc
2 1 Content Page 2 Overview Page 8 BD Series Base panel air/dirt eliminator Page 9 BS Series Base panel hydraulic separation Page 10 ZV Series Base panel with zone valves Page 11 DR Series Radiant add-on panel with outdoor reset mixing valve Page 12 DRD Series Radiant add-on panel with setpoint mixing valve Page 14 DS Series Add-on panel for circulator zones Page 15 DZV Series Add-on panel for zone valves Page 16 Page 17 Page 20 Page 21 Page 22 Page 23 HX Series Circulator Selection Zone Valve Control Switching Relay Zone Sentry Zone Valve iseries MixingValve
3 2 Hydronic Assemblies Inc. Hydronic Mechanical Panel System Hydronic Assemblies Inc. (HAI) mechanical panels are designed for the professional hydronic heating and cooling technicians. These panels are piped just like the pros do it in the field. They are preassembled; pressure tested and prewired on a rugged powder coated plate steel platform that promotes speed and quality of the installation. We use common parts and components for familiarity and ease of service. The system consists of a starter/base panel and add-on distribution panels. Choose between hydraulic separation and air/dirt eliminator for your starter panel and then add the appropriate add-on panel to complete your near boiler piping. Multiple circulator choices for each panel ensures full customization to meet the project zone requirements. Base Panels BD Series: This base panel has an air/dirt eliminator, zone control, 2-1 pumped zones. It is typically used with an oil boiler, modulating gas boiler with hydraulic separation, distribution side of a buffer tank or any heat/cool source where hydraulic separation is not required. Standard circulators have high efficiency ECM motor designs. BS Series: This base panel has a hydraulic separator, zone control, source side pump, fill & vent, expansion tank tee, air vent, dirt drain and 2-1 pumped zones. The BS Series is typically used with a modulating gas boiler without hydraulic separation, air to water heat pump, water to water heat pump (Geothermal) and any other heat/cool source where hydraulic separation is required. Standard circulators have high efficiency ECM motor designs. BS-ZV Series: This base panel has a hydraulic separator, zone control, source side circulator, fill & vent, expansion tank tee, air vent, dirt drain and a distribution circulator with 2 Zone Valve
4 3 controlled zones. This is the most efficient panel system and consumes much less energy than systems with circulator zones. BD-ZV Series: This base panel has an air/dirt eliminator, zone control, source side pump and a distribution side circulator with 4 Zone Valve controlled zones. This is the most efficient panel system and consumes much less energy than systems with pumped zones Base Panel Construction 12 gauge steel with structural reinforcing bends and mounting holes Dimensions Width - 41 Height /8 Depth - 10 ½ Powder coated white matte finish 1 ¼ main plumbing connections 1 Zone connections Distribution Panels DR Series: The DR distribution panel is a radiant panel designed to be combined with a base panel. The DR panel has a Taco 3 way valve with outdoor reset control and 2 1 zones with circulators. This panel can be used in any pumped zone application that requires a mixing control such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat. The DR panel will utilize either the control on the Base Panel or the SR504-4 EXP control located on the DRC Distribution Panel (see Base Panel and Distribution Panel control selections). Standard circulators have high efficiency ECM motor designs. DS Series: The DS distribution panel, which is added to a base panel, has 2 1 zones with circulators. This panel can be used in any pumped zone application such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat if no mixing valve is required. This panel
5 4 will utilize the zone controller of the Base Panel. Standard circulators have high efficiency ECM motor designs. HX Series: The HX Series panel is a stand-alone panel that provides absolute system isolation when connecting an anti-freeze loop with the home water based hydronic system. A typical application would be connecting a Monobloc Air>Water Heat Pump system to the homes water based system. This panel ideally suited for connecting heat pump system to a buffer tank. The panel utilizes a Taco SR504-4 relay to control the panel pumps. Standard circulators have high efficiency ECM motor designs. ZV Series: The ZV distribution panel is a complete 2 zone addition to the ZV Base panels. The ZV Series panel has 2 1 zones with zone valves on the distribution supply piping. The ZV panel will utilize the Taco ZVC404-4 zone valve controller located on the ZV Base panel. This panel is perfect for gas boilers, oil boilers and Air > water HPs. circulators have high efficiency ECM motor designs. Distribution Panel Construction 12 gauge steel with structural reinforcing bends and mounting holes Dimensions Width 18 ¾ Height /8 Depth - 10 ½ Powder coated white matte finish 1 ¼ main plumbing connections 1 Zone connections
6 5 Mix and Match Select the panels you need for a complete prefabricated panelized system. BD Series Base panel DS Series add-on Air/Dirt separation with 4 zones applicable to baseboard, indirect DHW, fan coil, radiant (outdoor reset boiler) BS Series Base panel DR Radiant panel DR radiant panel Hydraulic separation with 1 zone indirect, 1 zone supplemental and 4 zones radiant with 2 temperatures
7 6 HX series BD Series base panel DR Radiant Panel Air > water HP or atmospheric storage connected to pressurized storage with 1 zone indirect DHW, 1 zone supplemental and 2 zones radiant BSZV Base panel DZV add-on panel Hydraulic separation and four zones utilizing zone valves
8 7 Panel Selection HAI has provided multiple panel combinations for system type and flow requirements. We recommend panel selection is made with the appropriate system requirements, such as, flow, head, temperature, outdoor reset, etc. The components section contains the circulator performance charts for correct circulator selection. Hydronic Assemblies Inc. takes no responsibility for selection of the individual panels. Panels are connected by soldered couplings.
9 8 Hydronic Base Panel BD Series Air/dirt eliminator, zone control, and 2-1 pumped zones. The BD Series is typically used with an oil boiler, modulating gas boiler with hydraulic separation, distribution side of a buffer tank or any heat/cool source where hydraulic separation is not required. Standard circulators have high efficiency ECM motor designs. Configurations Model number BD200 BD204 BD201 1 Zone Circulators Taco VR1816-HY1-FC2A00 Taco VT2218FS Taco 007-F5-8IFC Control: Taco SR zone circulator control Control Option: Taco SR506-4 Additional Features: Pressure tested - Pressure testing port with pressure gauge included Prewired - Integral flow checks on all circulators Legend T-88 Air and Debris eliminator with fill system including backflow preventer and expansion tank attachment point
10 9 BS Series Hydraulic separator, zone control, source side pump, fill & vent, expansion tank tee, air vent, dirt drain and 2-1 pumped zones. The BS Series is typically used with a modulating gas boiler without hydraulic separation, air to water heat pump, water to water heat pump (Geothermal) and any other heat/cool source where hydraulic separation is required. Standard circulators have high efficiency ECM motor designs. Configurations Model number Source side circulator 1 Zone Circulators 1 ¼ BS200 Taco VR1816-HY1-FC2A00 Taco VR1816-HY1-FC2A00 BS211 Taco 007-F5-8IFC Taco 007-F5-8IFC BS204 Taco VR1816-HY1-FC2A00 Taco VT2218FS BS201 Taco VR1816-HY1-FC2A00 Taco 007-F5-8IFC Control: Taco SR zone circulator control Control Option: SR zone circulator control Additional Features: Pressure tested -Pressure testing port with pressure gauge included Prewired - Integral flow checks on all circulators - Legend HS-808 hydraulic separator
11 10 ZV Series There are two simple Zone Valve Base Panels to fulfill project requirements. ZV-001 has a hydraulic separator, zone valve control, one source side circulator and two distribution side 1 zone valves. The ZV-001 is designed for use with any heat/cool source that requires hydraulic separation. ZV-002 has an air/dirt separator, zone valve control, one system circulator and four (4) 1 zone valves. This is a complete system panel for projects up to 4 zones and can be expanded by adding a DZV zone add-on distribution panel. ZV-002 ZV-001 Model # Source side Distribution side Zone Valves circulator circulator ZV001 Hydro Sep Taco VR1816 Taco VR1816 Taco Z100C2-1 2 each ZV002 Air/dirt Taco 0013 Taco VR1816 Taco Z100C2-1 4 each Control: Taco ZVC zone circulator control Control Option: none Additional Features: Pressure tested -Pressure testing port with pressure gauge included Prewired - Integral flow checks on all circulators - Legend HS-808 hydraulic separator
12 11 Radiant Distribution Panel DR Series The DR distribution panel, which is added to a base panel, has a Taco 3 way valve with outdoor reset control and 2 1 zones with circulators. This panel can be used in any pumped zone application that requires a mixing control such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat. The DR panel will utilize the Base Panel circulator relay control for circulator operation. Standard circulators have high efficiency ECM motor designs. A three way valve with electronic mixing and outdoor reset provide precise temperature control for efficient radiant operation. Configurations DR000 DR001 DR002 Model # 1 Zone Circulators X 2 Taco Viridian VT2218 Taco Viridian VR1816 Taco 007 IFC Control: DR Series will utilize the Base Panel. Mixing Valve: The DR series panel utilizes the Taco I100U3R-1 3 way mixing valve with integral outdoor reset temperature control. The direct drive actuator modulates the 3-way valve that injects different rates of hot water, supplying virtually any water temperature to the heating system. Working off an adjustable reset ratio, the valve s maximum and minimum system supply temperatures can be adjusted to support all types of radiant applications. Additional Features: Pressure tested integral flow checks
13 12 Radiant Distribution Panel DRD Series The DRD distribution panel, which is added to a base panel, has a manual Taco 3 way valve and 2 1 zones with circulators. This panel can be used in any pumped zone application that requires a mixing control such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat. The DR panel will utilize either the control on the Base Panel or the SR504-4 EXP control located on the DRD Distribution Panel (see Base Panel and Distribution Panel control selections). Standard circulators have high efficiency ECM motor designs. Panel Construction 12 gauge steel with structural reinforcing bends and mounting holes Dimensions Width - 39 ¼ Height /8 Depth - 10 ½ Powder coated white matte finish 1 ¼ main plumbing connections
14 13 Configurations Model # 1 Zone Circulators X 2 DRD000 Taco VT2218 DRD001 Taco Viridian VR1816 DRD002 Taco 007 IFC DRD003 Taco 0013 Control DRD Series will utilize either the Base Panel control or it will utilize the SR504-4 EXP located on a controlled Distribution Panel. Note: The base panel selected must also have the Taco EXP control when adding a controlled distribution panel. Mixing Valve The DRD series panel utilizes the Taco 3 way mixing valve with a downstream thermometer for temperature readings. This simple distribution panel works well for applications where a fixed circulation temperature is acceptable. Additional Features Pressure tested Integral flow checks
15 14 Hydronic Distribution Panel DS Series The DS distribution panel, which is added to a base panel, has 2 1 zones with circulators. This panel can be used in any pumped zone application such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat if no mixing valve is required. This panel will utilize the zone controller of the Base Panel. Standard circulators have high efficiency ECM motor designs. Configurations DS000 DS001 DS002 Model # 1 Zone Circulators X 2 Taco VT2218 Taco Viridian VR1816 Taco 007 IFC Control DS Series utilizes the Base Panel circulator control Additional Features Pressure tested Integral flow checks on all circulators
16 15 Hydronic Distribution Panel DZV Series The DZV-003 distribution panel, which is added to the BZV-001 or BZV-002 Base Panel, has 2 1 Zone Valve controlled zones. This panel can be used in any pumped zone application such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat if no mixing valve is required. This panel will utilize the zone valve controller of the BZV-001 or BZV-002 Base Panel. Control DZV-003 Series utilizes the ZV-001 or ZV-002 Base Panel zone valve control Additional Features: Pressure tested Prewired to connect with the Base Panel
17 16 Heat Exchanger Panel HX Series The HX Series panel is a stand-alone panel that provides absolute system isolation when connecting an anti-freeze loop with the home water based hydronic system. A typical application would be connecting a Monobloc Air>Water Heat Pump system to the homes water based system. This panel ideally suited for connecting heat pump system to a buffer tank. The panel utilizes a Taco SR504-4 relay to control the panel pumps. Standard circulators have high efficiency ECM motor designs. Configurations Model # Source side circulator Taco FTP 5 X 12 X 30 plate Distribution side circulator HX001 Taco plate HX Taco VR1816 HX002 Taco VR Plate HX Taco VR1816 Control: Taco SR504-4 circulator relay Heat Exchanger: Taco FTP 5 x 12 x 30 plate heat exchanger with 1 ¼ ftgs Additional Features: Pressure tested - Pressure testing port with pressure gauge included Prewired - Integral flow checks
18 17 Circulator Selection Taco VT2218: The TACO Viridian VT2218 comes with two temperature sensors to provide Delta-T readings to the pump's controller. The Viridian VT2218 circulator is a temperature sensing, self-adjusting, variable speed wet rotor circulator with an ECM permanent magnet motor. Operating modes include Delta-T differential temperature, 4 fixed speeds, set point heat, set point cool and boiler protection. Typical uses include hydronic systems zoned with zone valves, radiant loops, injection pumping, snow-melt or hydro-air fan coils. It can also be used in constant speed mode for zoning with circulators, indirect water heaters or primary boiler loops.
19 18 Taco Viridian VR1816 The Viridian VR1816 circulator is an infinitely variable speed, high-efficiency wet rotor circulator with an ECM permanent magnet motor. Operating modes include infinitely variable fixed speed to fine tune any zone, self-adjusting constant pressure for zone valve applications and selfadjusting proportional pressure for panel radiators with thermostatic radiator valves. It s simple to install and intuitive to set up. An LED displays operating mode, error codes diagnostics and Sure Start automatic activation. The Viridian uses up to 85% less energy than circulators without ECM technology. Taco VR1816
20 19 Taco 0013 The high-performance Taco Speed circulator is designed for high-head/high-flow, large residential/light commercial hydronic heating and chilled water cooling systems. The 3-Speed switching ability lets you fine tune the performance to match a wide range of applications. Taco 007 IFC: The Taco 007 is a cartridge style, maintenance free, wet-rotor, in-line, single stage circulator pump. It is designed for quiet operation in Hydronic heating, Radiant heating, Hydro-Air fan coils, Indirect water heaters, Chilled fresh water, and Domestic Water Recirculation systems. Note: Circulator performance curves and circulator description courtesy of Taco Inc...
21 20 Zone Valve Control Simplify the wiring nightmare! Taco Zone Valve Controls easy-to follow PC board layout eliminates the problems caused by incorrect wiring, while the external indicator lights provide instant diagnostic feedback. Combined with Taco Zone Valves and Thermostats, the system s performance and dependability is maximized. Zone Valve Controls Taco Zone Valve Controls work with two-, three-, or four-wire zone valves. Fully fuse protected, they also include two isolated end switches and built-in priority protection. The contractor friendly PC board layout eliminates the problems caused by incorrect wiring and the unfinished look of conventional zone valve installations. The sturdy screw connections add additional reliability, while the external indicator lights provide instant diagnostic feedback, reducing installation time. All Taco Zone Valve Controls are UL listed and carry an extended 3 year warranty. Taco Expandable Zone Valve Controls Whether you want to expand up to 120 zones or utilize the advanced features of the Add-on Power Controls, Taco -EXP controls allow for simple integration of advanced features. Built-in Post Purge and Pump Exercise functions can optimize the operation of any system.
22 21 Circulator Switching Relay The Taco Switching Relay is the best choice for all your zoning needs, with advanced timer and boiler functions, external diagnostic lights, switchable priority and contractor friendly PC board layouts. Combined with the time proven reliability of the 00 family of circulators and thermostats, total system integration is achieved. Switching Relays Taco Switching Relays combine clearly labeled PC board layouts with advanced features that allow for total system customization. Whether using basic priority switching or the advanced features of the -EXP controls, the job is made easy. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups. All switching relays are UL listed, are compatible with conventional and programmable thermostats. Taco Expandable Switching Relays Whether you want to expand up to 120 zones or utilize the advanced features of the Add-on Power Controls, Taco -EXP controls allow for simple integration of advanced features. Built-in Post Purge and Pump Exercise functions can optimize the operation of any system.
23 22 Zone Sentry Zone Valve The Taco Zone Sentry Zone Valve enhances the overall performance of any zone valve system. The unique patented technology in the Zone Sentry utilizes microcircuit based logic to control a gear driven electronic actuator which drives a ball valve based body design. All this adds up to a zone valve that leads the industry in energy efficiency, flow capacity (C v ), shutoff pressure rating, ease of installation, diagnostic capability and the number of valves (12) that can be use on a standard 40VA transformer. Taco Zone Sentry zone valves are available in sweat, threaded, 3/4 Press Connection, Inverted Flare 3/4 sweat and 3-way configurations. Application: Taco Zone Sentry Zone Valves provide on-off, normally open or normally closed control in both open and closed hydronic systems. The valves can be used in a wide variety of heating and non-condensing cooling applications, primarily designed for use with baseboard, fan coils, radiators, convectors, air handlers, heat pumps and radiant applications. Ease of Installation / Operation: The Taco Zone Sentry is the most technologically advanced zone valve ever made. It s also simple to install and operate. The valve can be installed in any direction, in any orientation. We then went a step further, allowing the operator to be mounted to the 2-way valve body in either direction, great for those tight baseboard jobs. Snap-in quick connects on the back of the valve make for a simple, secure and fast wiring hook-up. A green LED light shows full functionality of the valve s operation and thermostat status. Under a no power situation the manual override button located on the top of the valve allows the ball to be rotated up to 90 and is also marked with a slot to indicate the position of the valve.
24 23 iseries MixingValve Taco iseries Mixing Valves are a breakthrough in precision, cost effective temperature control for heating systems. The iseries valves are available in two versions, providing either outdoor reset control or fixed water supply temperature by modulating the position of a 2-way, 3-way or a 4-way valve. Additionally, iseries valves protect the boiler against flue gas condensation. A microprocessor-based control is built into the valve actuator, to which all wiring connections are made. All-in-one iseries Mixing Valves deliver optimum zone-by-zone temperature control, with built-in boiler protection. Outdoor Reset Application: Use the Taco Outdoor Reset iseries Mixing Valves instead of a conventional injection system. With a full featured outdoor reset control built right into the actuator there is no need for an externally mounted reset control or expensive control valve. The iseries valves can also be set up to do zone-by-zone outdoor reset, providing optimal comfort control for every zone. New 3-way ivalve with union connections makes for an easy change-out of any thermo- static mixing valve. Instantly improve the comfort and energy efficiency of any job by dropping in an Outdoor Reset ivalve in place of any fixed temperature mixing valve. The direct drive actuator modulates a 2-way, 3-way or 4-way valve that injects different rates of hot water, supplying virtually any water temperature to the heating system. Working off an
25 24 adjustable reset ratio, the valve s maximum and minimum system supply temperatures can be adjusted to support all types of jobs, including staple-up radiant floors that require a higher starting temperature. The iseries valves include an adjustable boiler protection function which prevents low water temperatures from returning to the boiler. With a multi-status LED indicator light, plug-in wiring connections and an easy to remove actuator, the installation could not be easier. Setpoint Application: Use the Taco Setpoint iseries Mixing Valves instead of a thermostatic mixing valve for precise dial-in temperature control to a heating system. In combination with the optional boiler protection sensor, the iseries valves provide the unique benefit of optimal temperature control with boiler protection. The setpoint temperature is adjustable from 80 F to 180 F using a dial located on top of the actuator. A 15 F setback of the supply water can be initiated for additional unoccupied or nighttime setback control. An external multi-status LED indicator light, plug-in wiring connections and an easy to remove actuator makes installation and diagnostics a snap.
Taco 00 Series Cartridge Circulators
Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential
More informationhydronic S Y S T E M S & C O M P O N E N T S
hydronic S Y S T E M S & C O M P O N E N T S 4 A message from John Hazen White, Jr. For over 85 years, Taco has never strayed from its founding mission to provide you with the most reliable, easy to install
More informationModular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS
Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel
More informationProRadiant Controls, Valves and Actuators
214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation
More informationBetter Design, Better Control, Better Systems.
Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning
More information- Data Brochure Universal Reset Module 422
- Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More information- Essay Control Functions and Benefits
- Essay Control Functions and Benefits E 005 07/01 A hydronic heating control system performs many complex and important functions. Each of these functions provide benefits that make the system comfortable,
More information- Data Brochure Universal Reset Module 423
- Data Brochure Universal Reset Module 423 D 423 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More informationHydronic & HVAC Control Systems
tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better
More informationBoiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand
Date Code - Data Brochure Universal Reset Control 374 D 374 10/03 The tekmar Universal Reset Control 374 is designed to maximize the comfort and effi ciency provided by a hydronic heating system. The control
More informationThe Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic
R Vie Menu % % 1 2 Item F! WWS Vie Menu % % 1 2 Item F! WWS 70 LR 58233 E150539 Universal Reset Control 363 - Data Brochure D 363 12/08 The Universal Reset Control 363 is a microprocessor based control
More informationAllcan TM Installation Manual
Allcan TM Installation Manual NOTICE: READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW INSTRUCTIONS VOIDS WARRANTY. Introduction: The PHP Allcan (USA patent pending) is a complete primary/secondary
More informationCirculators high efficiency ECM Circulators
Circulators high efficiency ECM Circulators Circulators high efficiency ECM Circulators Small ECM circulators now available in North America Grundfos Alpha: Provides constant and proportional differential
More informationTable of Contents. 2 - JTG Muir - Taco Catalog
Table of Contents Table of Contents 2 3-Speed 00-Series Circulators 3 00 Series Cartridge Circulators 4 Taco 00 Wet Rotor Circulator Cross Reference 5 Variable Speed Delta & 00 Circulators 7 Priority Zoning
More informationknow exactly what you are getting before you order it. You can order with confidence knowing th each panel is completely tested before it ships.
y y y Imagine know exactly what you are getting before you order it. You can order with confidence knowing th each panel is completely tested before it ships. Quick-ship panels are available for almost
More informationRadiant Mixing Block
EFFECTIVE: arch 1, 2004 Taco Radiant ade Easy Application Guide Radiant ixing Block Products & Applications PA09 SUPERSEDES: New OVERVIEW Radiant ixing Block The Taco Radiant ixing Block (RB) is a complete
More informationThermostatic Radiator Valves (Caleffi)
02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled
More information- Data Brochure Universal Reset Control 364
70 7 8 9 - Data Brochure Universal Reset Control 364 D 364 07/01 The Universal Reset Control 364 is designed to maximize the comfort and efficiency provided by a hydronic heating system. The control automatically
More informationOutdoor Reset IQ Option Card, p/n
Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...
More informationHydronic Accessories
ydronic ccessories Zone Sentry Series The Taco Zone Sentry Zone Valve enhances the overall performance of any zone valve system. The unique patented technology in the Zone Sentry utilizes a microcircuit
More informationpropanel Series Installation Manual
propanel Series Installation Manual propanel Series Installation Manual is published by Uponor Wirsbo 5925 148th Street West Apple Valley, MN 55124 (952) 891-2000 2003 Uponor Wirsbo All rights reserved
More information- Data Brochure Mixing Control 361
TIME PRGM 1 2 AMPM UN OVR S M T W T F S - Data Brochure Mixing Control 361 D 361 05/00 The Mixing Control 361 is designed to control the supply water temperature to a hydronic system in order to provide
More informationWWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223
Dial the desired duration of the period. Press start button at the time of day you want the UnOcc. period to begin. light turns on. 0 = always = always Pump / Vlv System Pump Zone / Cooling NRTL/C LR 58
More informationHeat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.
Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow
More informationOutdoor Reset IQ Option Card, p/n
Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...
More informationThe PurePro. Family of Indirect Water Heaters. A smart choice for abundant, rapid hot water heating. pureproproducts.com
The PurePro Family of Indirect Water Heaters A smart choice for abundant, rapid hot water heating pureproproducts.com PurePro Indirect Water Heaters: The best option for home hot water needs As overall
More informationHeat Link. Technical Guide
Heat Link Stat Link Technical Guide Third Version, May 2011 1 Table of Contents Thermostatic Zones Defined...................................... 4 StatLink System Components.....................................
More informationqualified heating installer/service technician
Instruction manual This manual must only be used by a qualified heating installer/service technician. Failure to comply could result in severe personal injury, death or substantial property damage. Part
More informationThe electrical wattage needed by the circulator is:
The electrical wattage needed by the circulator is: w e = 0.4344 f P n w/w A current-generation wet-rotor circulator has a maximum wire-towater efficiency in the range of 25 percent. If we put the data
More informationInstruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA
Instruction Sheet PC2 1 Two Stage Reset & Control SUPERSEDES : 102-106, dated June 1, 2000 EFFECTIVE: March 1, 2004 Plant ID# 9300-1059 Item 102-106 The PC2-1 is a microprocessor-based control designed
More informationThe PurePro. Family of Indirect Water Heaters. A smart choice for abundant, rapid hot water heating. pureproproducts.com
The PurePro Family of Indirect Water Heaters A smart choice for abundant, rapid hot water heating pureproproducts.com PurePro Indirect Water Heaters: The best option for home hot water needs As overall
More informationDHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override
Date Code - Data rochure oiler Control 265 D 265 10/03 The tekmar oiler Control 265 can control the supply water temperature on up to three modulating boilers based on outdoor temperature or setpoint requirements.
More informationHVAC No. MFG Part No. Description Size Price
Circulator Isolation Flanges and Valves Webstone 113460 113462 113464 113466 390608 390564 Flanged Isolation Valves 110-251F 110-252F 110-253F 110-254F SF-075T SF-100T Freedom Flange, Cast Iron Freedom
More informationHydronic Specialties and Circulator Pumps
Hydronic Specialties and Circulator Pumps PAGE 445-1 Boilermate Indirect-Fired Water Heater Uses any hot water boiler or generator to supply domestic hot water more efficiently than tankless coils and
More informationCONTROLLED CHILLED BEAM PUMP MODULE
ENERGY SAVINGS 1 ST COST SAVINGS PROACTIVE CONTROL CONTROLLED CHILLED BEAM PUMP MODULE Active condensation control system effectively eliminates chilled beam condensation High efficiency, variable speed
More informationApplication Guide. Vitodens 100-W B1HA/B1KA Residential Boiler
Application Guide Vitodens 100-W B1HA/B1KA Residential Boiler APPLICATION GUIDE The application examples contained in this document serve as a guideline only. These are not engineered drawings and are
More information- Data Brochure D 260. Boiler Control /09
- Data Brochure Boiler Control 260 D 260 03/09 The Boiler Control 260 is designed to control a single stage heat source in order to provide outdoor reset or Domestic Hot Water () operation. The control
More informationunion swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve
VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging
More informationINSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE
INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE
More information- Data Brochure Mixing Control 360
- Data Brochure Mixing Control 360 D 360 03/09 The Mixing Control 360 is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset or setpoint operation. The
More informationVariable Speed Outdoor Reset 00 Circulator (00-VR)
Taco Radiant ade Easy Application Guide Variable Speed Reset 00 Circulator () EFFECTIVE: arch, 2004 Products & Applications PA03 SUPERSEDES: New OVERVIEW Variable Speed Reset 00 Circulator () The is a
More informationGETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS
GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS Copyright 2011. R. Trethewey, All rights reserved. No part of this document or file may be used without permission of the author. All diagrams are conceptual
More informationHeat Pumps COMFORT NEED IT. When You
Heat Pumps COMFORT When You NEED IT COMFORT When You NEED IT SpacePak s Solstice heat pumps are air-to-water reverse cycle heat pumps that use the comfort of Hydronics as the primary source for both heating
More informationAdvanced Heating & Hot Water Systems
TP Made In America Advanced Heating & Hot Water Systems A Trailblazing Appliance that Installs Like a Mid-Efficiency Boiler with the Performance of a High-Efficiency Product HHTP Made In America Up to
More information"Best Practices in Modern Hydronic Heating - THE DETAILS
"Best Practices in Modern Hydronic Heating - THE DETAILS 190 supply water temperature (ºF) 170 150 130 110 90 fin-tube convector (RR=1.38) panel radiator (RR=1.0) thin slab rad. floor (RR=0.69) slab r
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationCommercial, Residential & Institutional Pumps, Tanks, & Accessories
Taco International Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco Catalog # : 300-6.0 Supersedes: 300-3.5 9/11/06 Effective Date: 03/21/07 Printed in USA Pumps FI Frame Mounted
More informationheat interface units A BOILER WITHOUT A FLAME
A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.
More informationThermostatic mixing valves with replaceable cartridge for centralized systems
Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is
More informationADVANCED HEATING AND HOT WATER SYSTEMS
P I O N E E R H E AT I N G A P P L I A N C E ADVANCED HEATING AND HOT WATER SYSTEMS The Pioneer is a trailblazing new appliance that installs like a mid-efficiency boiler with the per formance of a high-ef
More information- Data Brochure Boiler Control 264e
- Data Brochure Boiler Control 264e D 264e 09/09 The kanmor Boiler Control 264e can control the supply water temperature from up to 4 on / off stages based on outdoor temperature, control for Domestic
More information95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR
CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR 5:1 TURNDOWN RATIO LESS THAN 20 ppm NOx 95% AFUE Efficiency DIRECT VENT
More informationLOCAL INVENTORY FOR QUICK SHIPMENT
LOCAL INVENTORY FOR QUICK SHIPMENT Territory Representation for Taco products since 1957: ALASKA 6657 Greenwood St. Anchorage, AK 99518 (907) 562 2608 (907) 562 0503 fax OREGON 27180 SW 95th Avenue Suite
More information96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR
CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR 5:1 FIRING RATE MODULATION LESS THAN 20 ppm NOx DIRECT VENT FLEXIBILITY TO 100 FEET 96% AFUE
More informationEASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work
EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How hydronic heating systems work Advantages Disadvantages Design alternatives Baseboard convectors Residential Hydronic Heating A residential
More information- Data Brochure Boiler Control 274
- Data Brochure Boiler Control 274 274_D 03/17 The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint operation with priority. When
More informationModular Panel System for Radiant Floor Heating.
Modular Panel System for Radiant Floor Heating Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel system an easy install and a great value
More informationInstallation & Operation Manual
Boiler Control 275 Installation & Operation Manual Multi-Staging D 275 01/12 Replaces:03/09 The Boiler Control 275 is designed to stage up to four condensing or non-condensing, modulating or on-off boilers
More informationCONTROLLED CHILLED BEAM PUMP MODULE
FIRST COST SAVINGS PROACTIVE CONTROL CONTROLLED CHILLED BEAM PUMP MODULE Active condensation control system effectively eliminates chilled beam condensation High efficiency, variable speed pump uses a
More informationQualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES
CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES 5 FLOOR-STANDING AND 5 WALL-MOUNT MODELS FROM 50,000 TO 285,000 BTU/HR FIRING RATE MODULATION TO 5:1 LESS THAN 20 ppm NOx
More informationADVANCED HEATING AND HOT WATER SYSTEMS
P I O N E E R H E AT I N G A P P L I A N C E ADVANCED HEATING AND HOT WATER SYSTEMS The Pioneer is a trailblazing new appliance that installs like a mid-efficiency boiler with the per formance of a high-ef
More informationLogamax plus GB142. Applications Manual. Gas condensing boiler
Applications Manual Gas condensing boiler WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury, loss of life or property damage. Refer to the installation and
More informationDomestic Hot Water Systems and Plumbing Products
Domestic Hot Systems and Plumbing Products Taco Catalog #100-117 Effective Date: 09/02/15 Supersedes: 06/22/15 Printed in USA Domestic Hot Recirculation Taco Domestic Hot Plumbing Products Since 1920 Taco
More informationCALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA
Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing
More informationInstruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators
Instruction Sheet Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators 102-358 SUPERSEDES: May 1, 2010 EFFECTIVE: October 1, 2010 Plant ID# 001-3921 The Variable Speed - Setpoint 00 Cartridge
More information- Data Brochure Boiler Control 264
- Data Brochure Boiler Control 264 D 264 11/03 The tekmar Boiler Control 264 can control the supply water temperature from up to 4 on / off stages based on outdoor temperature, control for Domestic Hot
More informationASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International
ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?
More informationAutomatic Temperature Controller (ATC)
NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet
More information- Data Brochure Boiler Control 268
- Data Brochure Boiler Control 268 D 268 11/10 The tekmar Boiler Control 268 can control the supply water temperature from up to 9 on / off stages based on outdoor temperature, control for Domestic Hot
More informationInstruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator
Instruction Sheet Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator The Variable Speed - Outdoor Reset 00 Cartridge Circulator (00-VR) is a microprocessor-based pump designed to regulate the
More informationTechnical Data Manual
VITOTRONIC 300 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating circuits Technical Data Manual Vitotronic 300 Model KW3, Part No. Z001 231 For operation
More informationBHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions!
BHSAPPMAN 08/00 USA Applications Manual Ecomatic / Logamatic Controls Save These Instructions! TABLE OF CONTENTS 1 2 3 4 5 6 7 8 Introduction 1 Terms 2-4 Description of Wiring Terminals 5-7 Application
More informationPlumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed
Plumbing ECM High-Efficiency Hot Water Recirculation System Enjoy instant hot water comfort while avoiding a major renovation. The Hot-LinkPlus-e system installs easily into existing plumbing with a tank
More informationThermostatic mixing valves with interchangeable cartridges
www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems
More informationBosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler
WARNING: Improper installation, setup, modification, operation or maintenance of the heating system can cause personal injury and property damage. Follow each appliances' instructions precisely. For assistance
More informationCaleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)
Caleffi North America, Inc. 3883 W. Milwaukee Road Milwaukee, WI 53208 T: 414.238.2360 F: 414.238.2366 LITERATURE RELEASE Caleffi Hydronic Solutions June 10, 2010 Contact: Rex Gillespie, Director of Marketing
More informationHeating Installation Guide published by
Heating Installation Guide published by MrPEX Systems 2613 87th Court W. Northfield, MN 55057 800-716-3406 mrpexsystems.com mrpex@mrpexsystems.com 2014 MrPEX Systems All rights reserved Printed September
More informationhydronics WHAT S WRONG WITH THIS SCHEMATIC?
BY JOHN SIEGENTHALER WHAT S WRONG WITH THIS SCHEMATIC? In the September/October 2005 issue of HPAC Magazine, methods to draw hydronic piping schematics were discussed. These drawings are an efficient way
More informationMascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing
Mascot Gas-Fired Residential and Commercial Wall-Mounted Boiler Easy Installation, 96% Efficiency, Fully Condensing Mascot is a high-efficiency, wall-mounted boiler available in three BTU sizes 126, 167,
More informationK-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform
Versa IC Platform VERSA IC Integrated Control Platform Raypak s VERSA IC combines modulating temperature control, safety limits, and ignition programming into one user- friendly Integrated Control Platform.
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationCombined Space and Water Heating: Making it Work
Combined Space and Water Heating: Making it Work High Efficiency Heating in a Single Package Ben Schoenbauer, Center for Energy and Environment Jake McAlpine, Sustainable Resource Center February, 26 th,
More informationWIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873
WIRIG GUIDE The ZSR101 is a versatile single relay control with two outputs for operating a 120 VAC with boiler enable, or two 120 VAC devices without boiler enable. Features include rear knock outs for
More informationDISTRIBUTION SYSTEMS. Water Piping and Pumps
DISTRIBUTION SYSTEMS Water Piping and Pumps Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They are targeted
More informationApplications and Piping Strategies for Condensing Boilers - Introduction
Applications and Piping Strategies for Condensing Boilers - Introduction Foil 2, 10/2015 Viessmann Manufacturing Applications and Piping Strategies for Condensing Boilers Webinar Objectives: 1. Control
More informationHPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations
Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control
More informationDual Mixing Application
HBX MIXING APPICATION The CPU-000 configured as a Mixing Control allows for mixing of hitemp boiler (supply) water with lower temp system water, bringing several benefits to a hydronic design and installation.
More informationIntelligent Heating for Your Home
Intelligent Heating for Your Home A Better Way to Heat Your Home Conventional Heating Systems Leave Your Home Too Hot or Too Cold Conventional residential heating systems lack the subtlety and sophistication
More information- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1
- Application Boiler Control & One Stage Setpoint Control 150 A -1 07/99 echanical Remote Display odule () 040 Outdoor Sensor () 070 150 ODE 1 Class II Transformer 120 V (ac) 24 V (ac) R1 A2 Z1 Z2 Z3 T1
More informationCALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function
Solar storage-to-boiler thermostatic connection kit 6-63 series REGI STERED BS EN ISO 900:000 Cert. n FM 64 UNI EN ISO 900:000 Cert. n 0003 CLEFFI 064/09 GB Function The solar storage-to-boiler connection
More informationWood Boiler Plumbing Schematics
Wood Boiler Plumbing Schematics Solo Plus Froling FHG Solo Innova Excel Multi-Fuel 2 TABLE OF CONTENTS Section Page 1.0 Introduction..4 2.0 Plumbing Diagrams....5 2.1 Plumbing Example-Solo/Excel 1........5
More informationInstruction Sheet 00 Variable Speed Delta T (00-VDT)
Instruction Sheet 00 Variable Speed Delta T (00-VDT) 102-359 SUPERSEDES: January 1, 2010 EFFECTIVE: May 1, 2010 Plant ID# 001-3927 The Variable Speed Delta T 00 Cartridge Circulator (00-VDT) is a microprocessor-based
More informationZoning Solutions. Thermostats & Wiring Centers Designed to Maximize Indoor Comfort. A Watts Water Technologies Company
Zoning Solutions Thermostats & Wiring Centers Designed to Maximize Indoor Comfort HVAC Systems Multi-Staging Alternative Energy Zoning Snow Melting Setpoint A Watts Water Technologies Company Zoning in
More informationInstallation & Operation Manual
tekmarnet 2 House Control 402 Installation & Operation Manual D 402 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 402 is designed to operate as part of a complete hydronic heating system
More informationControl Panel Checklist
Control Panel Checklist Versatronik -C Panel Checklist Option Selection for Control Panel Quotes Checklist Control Panel Checklist Section 1 General Information Customer name Phone number Fax number Email
More informationTOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal
TOTAL SYSTE EFFICIENCY: CONTROL STRATEGIES & SYSTE DISTRIBUTION David Grassl PE echanical Engineer Principal This is the second paper in the total system efficiency series that will detail various control
More informationInstallation & Operation Manual Models: TSU
TSU-I-O Rev A Installation & Operation Manual Models: TSU 150-940 CAUTION: This appliance is not intended for potable water. This manual must only be used by a qualified heating installer / service technician.
More information4 Wiring Brochure Wiring and
- Brochure tekmarnet 4 Thermostat 544 D 544 06/05 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough In Wiring Rough-in 4 Wiring
More informationInstallation & Operation Manual
tekmarnet 2 House Control 400 Installation & Operation Manual D 400 09/13 HVAC Systems Replaces: 09/10 Introduction The tn2 House Control 400 is designed to operate all of the mechanical equipment in a
More informationProRadiant Manifolds, Stations and Fittings
Manifolds, Stations and Fittgs 197 Staless Manifolds and Accessories # of Outlets STAINLESS MANIFOLD - SHUT-OFF / BALANCING / FLOW METERS These preassembled 1-1/4" diameter staless supply and return manifolds
More information