NovaVent. Dimensional Data
|
|
- Abner Benson
- 5 years ago
- Views:
Transcription
1 NovaVent Dimensional Data
2 NovaVent The new vent system designed and engineered for today s competitive sales environment. NovaVent NovaVent is designed and engineered to meet the requirements of gas-fired ategory III tankless water heaters, complete with a factory installed gasket joining system and manufactured in 3, 4 and 5 diameters. NovaVent is produced to the same consistent high quality manufacturing standards that meet the superior performance and increased efficiency of all Z-Flex products. U.S.A. ANADA 20 ommerce Park North, edford, NH Attwell Drive, Etobicoke, ON M9W 53 tel: fax: tel: fax: sales@z-flex.com NovaVent is manufactured by Z-Flex US, a Novaflex Group ompany rev
3 NovaVent Typical Horizontal Sidewall Termination Single-Wall ategory II, III & IV UL inches Maximum Support Hangers Termination Hood (alternate) Wall Thimble 45 Elbow 90 Elbow Adjustable Vent Length Vent Pipe Length Adjustable Vent Pipe Length Termination oupling Screen 3-in-1 Adaptor with ondensate Drain Water Heater NovaVent ANSI ategory II, III, IV Stainless Steel Vent System culus Listed 1738/H Slope the horizontal section of the vent system ¼ inch per ft up towards the termination to determine the location for the Wall Thimble installation. Any condensate created in the vent system should drain back towards the installed condensate drain. 2. Support hangers available for 1 unenclosed clearance or for 4 enclosed clearance. Refer to the learance Table in the Installation Guide. NovaVent is manufactured by Z-Flex US, a Novaflex Group ompany
4 Typical Typical Vertical Through the Roof Termination Single-Wall ategory II, III & IV UL 1738 NovaVent Extreme Weather Rain ap Top Support Adjustable Flashing Firestop Support ondensate Drain 48 inches Max 90 Elbow Support Hangers Firestop Spacer Adjustable 90 Elbow Adjust ondensate Tube with P-Trap Appliance Adaptor Water Heater NovaVent ANSI ategory II, III, IV Stainless Steel Vent System culus Listed 1738/H Slope the horizontal section of the vent system ¼ inch per ft up towards the termination. Any condensate produced in the vent system should drain back towards the installed condensate drain. 2. Support hangers available for 1 unenclosed clearance or for 4 enclosed clearance. Refer to the learance Table in the Installation Guide. NovaVent is manufactured by Z-Flex US, a Novaflex Group ompany
5 NovaVent NovaVent Pipe Available in diameters 3, 4, 5 and standard lengths up to 4ft. Pipe can be cut to length. The female end of each component incorporates a Double Fail Safe self sealing gasket. Examine all components to ensure that gasket integrity has remained during shipping. Gaskets must be in proper position or flue gases could leak resulting in carbon monoxide poisoning. The installation shall be in accordance with the manufacturer s installation instructions. A Part Number Description 3in NVP3.5 Pipe 3in x 6in NVP31 Pipe 3in x 1 ft NVP31.5 Pipe 3in x 1.5ft NVP32 Pipe 3in x 2ft NVP33 Pipe 3in x 3ft NVP34 Pipe 3in x 4ft NVP35 Pipe 3in x 5ft 4in NVP4.5 Pipe 4in x 6in NVP41 Pipe 4in x 1 ft NVP41.5 Pipe 4in x 1.5ft NVP42 Pipe 4in x 2ft NVP43 Pipe 4in x 3ft NVP44 Pipe 4in x 4ft 5in NVP5.5 Pipe 5in x 6in NVP51 Pipe 5in x 1 ft NVP51.5 Pipe 5in x 1.5ft NVP52 Pipe 5in x 2ft NVP53 Pipe 5in x 3ft NVP54 Pipe 5in x 4ft Two Piece Adjustable Pipe The use of adjustable pipe may be required when the system must be located within extremely tight installation parameters Part Number Description 3 Adjustable Lengths 2NVALS3 7"-9.9" Adjustable Length 2NVALM3 9"-13.9" Adjustable Length 2NVALL3 13"-21.9" Adjustable Length 4 Adjustable Lengths 2NVALS4 7"-9.9" Adjustable Length 2NVALM4 9"-13.9" Adjustable Length 2NVALL4 13"-21.9" Adjustable Length 2NVALXL4 36" " Adjustable Length 5 Adjustable Lengths 2NVALS5 7"-9.9" Adjustable Length 2NVALM5 9"-13.9" Adjustable Length 2NVALL5 13"-21.9" Adjustable Length 2NVALXL5 36" " Adjustable Length NovaVent is manufactured by Z-Flex US, a Novaflex Group ompany
6 Universal Adapter 6in (Double Female) Adapts appliance collar to the pipe. Pipe with Inspection Port Vent length with test port allows easy access for flue gas analysis. A TEST PORT A Part Number Description NVAFF3 Appliance Adaptor 3 in NVAFF4 Appliance Adaptor 4 in NVAFF5 Appliance Adaptor 5 in A Part Number Description NVTP3 Inspection Port Pipe 3 in NVTP4 Inspection Port Pipe 4 in NovaVent NVTP5 Inspection Port Pipe 5 in Vertical Tee with Drain A tee is used to connect horizontal and vertical vent sections Ø Installed /L A Part Number Description NVVDT3 Vertical Tee 3 in NVVDT4 Vertical Tee 4 in NVVDT5 Vertical Tee 5 in Vertical Drain Pipe Used to drain condensate from the Vent system. High temperature Drain Tube kit sold separately. DRAIN FITTING A Part Number Description NVVD3 Vertical Drain Pipe 3" NVVD4 Vertical Drain Pipe 4" NVVD5 Vertical Drain Pipe 5" 45 Elbows 45 elbows are used when a direction change or offset is required. 45 A Part Number Description NVE345 Elbow 45 X 3 in NVE445 Elbow 45 X 4 in NVE545 Elbow 45 X 5 in 90 Elbows 90 elbows are used when a direction change or offset is required. A Part Number Description NVE390 Elbow 90 X 3 in NVE490 Elbow 90 X 4 in NVE590 Elbow 90 X 5 in NovaVent is manufactured by Z-Flex US, a Novaflex Group ompany
7 NovaVent Eccentric Increaser Used to upsize a vent system. Recommended for use with horizontal vent runs. Ø D FLUE GAS FLOW A D Part Number Description NV1 Eccentric Increaser 5 to 6 in NV1 Eccentric Increaser 5 to 7 in NV1 Eccentric Increaser 5 to 8 in Termination Hood A Part Number Description NVTH3 Termination Hood 3 in NVTH4 Termination Hood 4 in NVTH5 Termination Hood 5 in Support Strap Vent supports are used to provide support to the vent system while maintaining proper clearance to combustible materials. As vertical supports are required after any 10ft run. These supports may also be used to support long horizontal runs, which require support every 6ft. an be used on horizontal and vertical runs. A A Part Number Description 3 1 2NVSS31 Single Wall Support Strap 3in 4 1 2NVSS41 Single Wall Support Strap 4in 5 1 2NVSS51 Single Wall Support Strap 5in A Part Number Description 3 4 2NVSS34 Single Wall Support Strap 3in 4 4 2NVSS44 Single Wall Support Strap 4in 5 4 2NVSS45 Single Wall Support Strap 5in Wall Thimble For use when the vent passes through a horizontal opening. Not required for non-combustible walls. 4-7 Ø A Part Number Description NVWT3L Wall Thimble 3 in NVWT4L Wall Thimble 4 in NVWT5L Wall Thimble 5 in Flashing Flat Flat flashing provides weather protection where the vent penetrates the roof or chimney. Use on flat or slightly sloped (5 slope maximum) roofs. A Part Number Description NVFF3 Flashing Flat 3 in NVFF4 Flashing Flat 4 in NVFF5 Flashing Flat 5 in NovaVent is manufactured by Z-Flex US, a Novaflex Group ompany
8 Flashing flashing provides weather protection where the vent penetrates the roof. Use on roofs with a pitch from /12-5/12 slope. A Part Number Description NVAF3 Flashing in NVAF4 Flashing in NVAF5 Flashing in NovaVent Extreme Rain ap A rain cap is designed to terminate a vertical stack and prevent the entrance of debris or rain into the vent. Includes wind band to prevent draft loss. 5 ØD + 4" ØD 3.25 A Part Description Number NVW3 Rain ap w/wind band 3in NVW4 Rain ap w/ wind band 4in NVW5 Rain ap w/wind band 5in Storm ollar For use in conjunction with flashing to provide weather protection. Ø A Part Number Description NVS3 Storm ollar 3 in NVS4 Storm ollar 4 in NVS5 Storm ollar 5 in Guy and A guy band is used to stabilize the vent above the roof line or where a vent support can not be used. Secure with 4 guy wires (not included). A Part Number Description NVG3 Guy and 3 in NVG4 Guy and 4 in NVG5 Guy and 5 in Firestop Support A fire stop is used on vertical systems to provide support and maintain the necessary clearance to combustible materials. (For sizes 5 and up gear clamp comes loose with no gear clamp bracket.) A Part Number Description NVFS3 Fire Stop Support 3in NVFS4 Fire Stop Support 4in NVFS5 Fire Stop Support 5in NovaVent is manufactured by Z-Flex US, a Novaflex Group ompany
Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS
Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS 3 & 4 SPECIAL STAINLESS STEEL VENTING SYSTEM FOR GAS BURNING APPLIANCES CATEGORY I, II, III, & IV TESTED AND LISTED BY UNDERWRITERS
More informationCorr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-1995 Listing No. MH26687 Testing No. 11EN
More informationCVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.
VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent
More informationFLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationSMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationOn-Demand Water Heater Installation Manual and Owner s Guide
On-Demand Water Heater Installation Manual and Owner s Guide R D R ANSI Z21.10.3 CSA 4.3 540 model only Gas Tankless Water Heater TM Suitable for combination potable water heating and space heating. Please
More informationTechnical and Dimensional Data. Saf-T Vent SC Plus
Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances
More informationAdvanced Venting Systems
Advanced Venting Systems 1 Z-Vent Special Gas Vent 3 Flexible Vent Connector Systems 5 Aluminium Chimney Liner System 7 Stainless Steel Chimney Liner System 9 Oval Liner System / Advancing the Industry
More informationZ-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric
Z-FLEX Advanced Venting Solutions Z-DENS Polypropylene Vent Systems for High Efficiency Condensing Appliances Single Wall Rigid Flexible Liner Concentric Z-Flex Joins Forces with Cox Geelen Z-Flex North
More informationPelletVent Multi-fuel venting system. UL 641.
PelletVent Multi-fuel venting system. UL 641. Specifications Applications PelletVent is designed for venting of pellet stoves and inserts. Consult appliance manual for additonal requirements. Materials
More informationANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.
NY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible
More informationMitchell Metal Products, Inc.
Mitchell Metal Products, Inc. Mitchell Metal Products Kosciusko, Mississippi Established 1924 H i g h w a y 1 2 E P. O. B o x 7 8 9 K o s c i u s k o, M S 3 9 0 9 0 O f f i c e : 6 6 2-2 8 9-7 11 0 o r
More informationANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.
ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible
More informationInstallation Instructions
Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS
More informationBDM Direct Vent systems are for use with direct vent gas fired appliances.
INSTALLATION INSTRUCTIONS Pro-Form DIRECT VENT SYSTEM Tested to ANSI Z21.88-2009 /CSA 2.33-2009 REPORT # 369-P-02b-6.5 Read through all venting and appliance instructions before beginning your installation.
More informationBy Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference
By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation
More informationOn-Demand Water Heater Installation Manual and Owner s Guide
On-Demand Water Heater Installation Manual and Owner s Guide ANSI Z21.10.3 CSA 4.3 510U only Models 110U Indoor 110U Outdoor 310U Indoor 310U Outdoor 510U Indoor 510U Outdoor Series 200 WARNING If the
More informationGAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.
ODV-B GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. N8A5E5 TABLE OF CONTENTS HORIZONTAL PIPING... PAGES 1-10 WARNINGS...
More informationOn-Demand Water Heater Installation Manual and Owner s Guide
On-Demand Water Heater Installation Manual and Owner s Guide ANSI Z21.10.3 CSA 4.3 510U (AT-D3U-IN/OS) only 110U Indoor (AT-KJr3U-IN) 310U Indoor (AT-K5U-IN) 510U Indoor (AT-D3U-IN) Models 110U Outdoor
More informationZ-DENS Polypropylene Vent Systems
Z-FLEX Advanced Venting Solutions Z-DENS Polypropylene Vent Systems for High Efficiency Condensing Appliances Single Wall Rigid Flexible Liner Cascade Concentric Affirmed as replacement to comparable PVC
More informationINSTALLATION AND SERVICE MANUAL
INSTALLATION AND SERVICE MANUAL HORIZONTAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED UNIT HEATERS USE 5 INCH KIT FOR UNITS WITH CAPACITIES 100,000 TO 250,000
More informationICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS
ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS The ICC Model VIC is a listed venting system designed for venting commercial and industrial appliances, condensing appliances,
More informationEasy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation
Easy to assemble Silicone gasket sealed Laser-welded seams Smooth joint connections 360 Lock-Tab secure rotation Evenly spaced inner and outer pipes Continuous column of air insulation Ultimate Pellet
More informationInstallation and Maintenance Instructions
Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas
More informationC. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.
SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for
More informationPellet Stove. Flex Pipe. Appliance Connector
Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel
More informationVertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"
Corr/Guard Direct Vent Water Heater Vent/Air Intake System Installation and service must be performed by a qualified installer, service agency or the gas supplier. Installation must meet all state and
More informationVenting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4
GOLD GV Water Boiler Series 3 & 4 Venting Supplement Direct Vent Through-Roof or Through-Unused-Chimney For use with Weil-McLain Through-Roof or Through- Unused-Chimney Termination Kit Kit part # 382-200-435
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For
More information200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual
M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for
More informationFasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex
FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination
More informationOn-Demand Water Heater Installation Manual and Owner s Guide
On-Demand Water Heater Installation Manual and Owner s Guide R D R ANSI Z21.10.3 CSA 4.3 510 model only 110 Indoor 310 Indoor 510 Indoor Models 110 Outdoor (USA Only) 310 Outdoor (USA Only) 510 Outdoor
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II
More informationVENT SYSTEM COMPONENTS
Chimney Liner Kits Chimney Liners - All Fuel Chimney Liners - Gas Made from durable, corrosion-resistant type 316 stainless steel Designed to be used with wood, oil, coal and non-condensing gas-fired appliances
More informationTwin Wall Installation Instructions And Maintenance Guide
Twin Wall Installation Instructions And Maintenance Guide Please read all instructions before beginning your installation. Failure to install this system in accordance with these instructions will invalidate
More informationInstallation & Maintenance Instructions
Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications
More informationTYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES
INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES LISTED TO ULC-S609 & UL641 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES
More informationTW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40
TW-Pro Twin Wall Insulated Flue System EN1856-1 T600 N1 W V2 L50040 G50 / O40 Approvals TW-Pro Twin Wall Insulated Flue System - TW-Pro has been specifically designed with the installer in mind with a
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS HORIZONTAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED DUCT FURNACES USE 5 KIT FOR UNITS WITH CAPACITIES 100,000 TO 200,000 BTU/HR
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For
More informationFasNSeal. Installation Instructions
Installation Instructions FasNSeal & FasNSeal W2 Single-wall and Double-wall special gas vent FasNSeal Flex Flexible chimney liner for special gas vent for Category II, III, and IV appliances FasNSeal
More informationGWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions
GWS Gas-Fired Water Boilers Venting Manual Hazard definitions Contents Page Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications pplications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationINSTALLATION AND SERVICE MANUAL
INSTALLATION AND SERVICE MANUAL VERTICAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED UNIT HEATERS USE 5 INCH KIT FOR UNITS WITH CAPACITIES 100,000 TO 250,000
More informationDirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.
DirectVent Pro Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. Specifications
More informationSaf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada)
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For Venting Residential,
More informationASX7-5-IOM-3 J
INSTALLATION INSTRUCTIONS 5" CONCENTRIC VENT TERMINAL KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 90,000 to 120,000 BTU/HR
More informationINSTALLATION OF VENTING SYSTEM COMPONENTS WARNING
INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING When installing the EVERHOT IGI model series direct vent water heaters, use only EVERHOT vent/air intake system kits and components. Installation and service
More informationASX7-4-IOM-6 J
INSTALLATION INSTRUCTIONS 4" COMBUSTION AIR INLET KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 30,000 to 75,000 BTU/HR SUPPLEMENT
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II
More informationPelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney
PelletVent Pro horizontal Kit Kit includes: Round horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KHA
More information2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR SKU Descrpition List
3" Pipe and Fittings GV36 3"x6" B VENT PIPE $12.44 GV312 3"x12" B VENT PIPE $11.13 GV318 3"x18" B VENT PIPE $14.40 GV324 3"x24" B VENT PIPE $17.89 GV336 3"x36" B VENT PIPE $23.09 GV348 3"x48" B VENT PIPE
More informationInstallation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent
Installation and Maintenance Instructions Saf-T Vent CI Plus Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent For Venting Commercial & Industrial Appliances Condensing Appliances Category
More informationDuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.
DuraPlus HTC ll-fuel, double-wall chimney system. ULC S629. Specifications pplications DuraPlus HTC is a double-wall, all-fuel chimney system for both the U.S. and Canada for use with wood stoves; fireplaces;
More informationP-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE
P-K MACH C1500H-C2000H Outdoor Boiler Kit Rev. 1.0 (08/7/2012) 1004905966 P-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE This manual is to be used in conjunction with the P-K MACH C1500H-C4000
More informationSaf-T Vent SC Plus/SC 316
Installation and Maintenance Instructions Saf-T Vent SC Plus/SC 316 Double Wall One Inch Air Space Special Gas Vent For Venting Residential and Light Commercial Appliances Category I,II,III,IV Appliances
More informationINSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT
C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS
More informationMODEL CF CEILING SUPPORTED CHIMNEY
Manufactured by Selkirk Canada Corp. - Hamilton, Ontario Installation Instructions for MODEL CF CEILING SUPPORTED CHIMNEY Round Top Storm Collar Flashing Attic Insulation Shield/Firestop Spacer Intermediate
More informationDetroit Radiant Products Co.
UH and FA Series Concentric Vent Kit Instruction Sheet Detroit Radiant Products Co. CVK-3, 4 or 6 Concentric Vent Kit Installation Instructions This instruction sheet is intended to describe the installation
More informationSUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS
Selkirk LLC Selkirk LLC Research & Development State Route 93 North & Sutton Road P.O. Box 631 Logan, OH 43138 9/21/2006 TO: Our Valued Customers FROM: Glen Edgar Director R&D SUBJECT: SELKIRK MODEL DT
More informationShasta Vent Inc All-Fuel HT Chimney Installation Instructions
Shasta Vent Inc All-Fuel HT Chimney Installation Instructions August 2015 v1.02 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.
More informationSpecial Gas Vent For Category II, III and IV Appliances UL/ULC Listed to UL1738 & ULC-S636
Special Gas Vent For Category II, III and IV Appliances UL/ULC Listed to UL1738 & ULC-S636 Model SWGV - Single Wall Model DWGV - Double Wall 1 Air Space Model DWGV1 - Double Wall 1 Fiber Insulation Model
More informationDURAVENT POLYPRO VENTING PRODUCTS
DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS VERTICAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED DUCT FURNACES USE 5" KIT FOR UNITS WITH CAPACITIES 100,000 TO 200,000 BTU/HR
More informationFasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex
FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination
More informationDetroit Radiant Products Co.
Detroit Radiant Products Co. CVK-3, 4 or 6 Concentric Vent Kit Installation Instructions This instruction sheet is intended to describe the installation of the Concentric Vent Kit. This kit is designed
More informationVentis Direct Vent. Installation Instructions
entis Direct ent Installation Instructions A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES), TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPRORTANCE THAT
More informationPOWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD
General APPLIES TO: Standard Power Vent, Fan Type Unit Heaters: Model UDAP & Model APD Standard Power Vent, Blower Type Unit Heaters: Model UDBP Form I-UD&APD Series-V-PV (05-17) Obsoletes I-UD&APD Series-V-PV
More informationCombustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.
System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC
More informationGB162 Concentric Horizontal Vent Kit
GB162 Concentric Horizontal Vent Kit FOR BUDERUS GB162 SERIES BOILERS Installation Instructions 2 Concentric Horizontal Vent Kit Installation Manual Data subject to change Bosch Thermotechnology Corp.
More informationThe intelligent alternative for flue gas venting systems
The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason
More informationBack to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions
Installation instructions Cascade Venting System for RTG 199HE Back to back Basic Set for units 1 and 2-7 736 501 253 6 720 811 762 / 238-50973-00A (2014/05) Table of contents Table of contents 1 Key to
More informationGas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems
H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.
More informationModel IVSI Positive Pressure Venting Systems
C O M M E R C I A L A N D I N D U S T R I A L V E N T I N G Model IVSI Positive Pressure Venting Systems Ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines and
More informationInstallation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro
Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
More informationInstallation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro
Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
More informationVenting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness
Venting Vent Material This unit is approved for installation using 4 x 6-5/8 in co-axial direct vent pipe and accessories manufactured by Simpson Dura-Vent. Follow the installation instructions supplied
More informationCHIMNEYS AND VENTS CHAPTER 8
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationMX 200. MX-200 Technical Specifications FEATURES:
MX-00 Technical Specifications MX 00 TOP VIEW 6.5 Includes: heater,, oil by-pass regulator, pump assembly, primary waste oil strainer, check valve,, oil supply strainer and..5 6.5 6 dia. flue 5.5.5 FEATURES:
More informationSide by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions
Installation instructions Cascade Venting System for RTG 199HE Side by side 6720804520-20.1V Extension Set for units 3 or 4-7 736 501 254 6 720 811 761 / 238-50976-00A (2014/05) Table of contents Table
More informationGOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4
GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3 venting Special gas vent system vent and combustion air supplement for 3 diameter venting. The following manufacturers AL29-4C Stainless Steel
More informationINSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS
OIL FIRED WATER HEATER INSTALLATION AND OPERATING INSTRUCTIONS Read these instructions thoroughly before starting INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS These instructions apply
More informationInstallation Instructions for use by heating contractor
Installation Instructions for use by heating contractor Vitocrossal 300 CU3A Rigid and Flex Pipe Venting Systems Product may not be exactly as shown Read and save these instructions for future reference.
More informationCQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH
Applies to: Form I-PDH-V Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH CUSTOMER AGENCY PROCESS CQS CONVERGENT QUALITY SYSTEM PRODUCT WARRANTY START-UP Power-Vent Indoor Model PDH General
More informationSingle Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054
MC-CG-105 EN_892054 WARNING Installation Manual CoxDENS PPs Incorrect installation of Flue System and Components, or failure to follow installation instructions, can result in property damage or serious
More informationDo not use this vent pipe or fittings for venting incinerators of any kind.
! CAUTION! Do not use this vent pipe or fittings for venting incinerators of any kind. C.S.A. Certified For Natural Gas Or Propane Tested For 100 LBS. ASME Working Pressure For correct installation of
More informationEngine Exhaust Boiler Stack Grease Duct Gas and Oil Vents Chimney Liner
All-in-One Piping System Positive Pressure Exhaust Systems up to 90-inch water column Models SWKL & SWFL - Single Wall Models DWKL & DWFL - Double Wall Air & Fiber Insulation Installation Instructions
More informationGas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10
Back wall Gas Stoves Model C34-NG10 C34-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa)
More informationCOMMON VENTING SYSTEM SUBMITTAL SHEET
COMMON VENTING SYSTEM SUBMITTAL SHEET Job Name: Location: Architect/Engineer: Wholesaler: Model No.: Notes: Total Vent Length: Total System Btu/h: FEATURES AND BENEFITS The Common Vent System provides
More informationNAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA
Navien America Inc. Specification Details for the Navien models: CR-210 CR-210A For Indoor Installation Only For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA,
More informationSL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D.
Typical Installations 0 8 9 Vertical Installation. Vertical Termination ap. Storm ollar. Flashing. Roof Support. Length. ttic Radiation Shield. Firestop 8. ecorative lack Plate 9. Length (lack) 0. Insulation
More informationINS A T LL T A ION, OPER T A ING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT WATER BOILER Warning: Improper installation, adjustment, alteration, service or maintenance
More information830 ES - Natural Gas 830 ES - Liquefied Petroleum (LP) Gas
830 ES INDOOR MODEL Temperature Modulated with Electronic Ignition Suitable for heating potable water only and space heating (Intended for variable flow applications) 830 ES - Natural Gas 830 ES - Liquefied
More informationPolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install
PolyPro : For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install Being Green, Being Responsible. DuraVent looks for
More informationInstallation Instructions for use by heating contractor
Installation Instructions for use by heating contractor Vitocrossal 300 CU3A Models 26, 35, 45, 57, 94, 125, 160, 199 Rigid and Flex Pipe Venting Systems Product may not be exactly as shown Read and save
More information2012 INTERNATIONAL FUEL GAS CODE VENTS
2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with
More informationMX 200. MX-200 Technical Specifications FEATURES:
MX-00 Technical Specifications MX 00 TOP VIEW 6.5 Includes: heater,, oil by-pass regulator, pump assembly, primary waste oil strainer, check valve,, oil supply strainer and..5 6.5 6 dia. flue 5.5.5 FEATURES:
More informationULC S636 System. PolyPro. PolyPro Flex. Terminations
PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Chloride free, environmentally safe. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene
More information