HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.
|
|
- Clifford Logan
- 5 years ago
- Views:
Transcription
1 HydroRite UVO 3 Troubleshooting Guide Residential TSG-UVO158a Copyright 2015 Hayward Industries Inc.
2 Safety Precautions Warning! When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS This product should be installed by a professional service technician or similar person who is qualified in electrical equipment installation. Improper installation and/or operation could cause serious personal injury, property damage or death. Improper installation and/or operation will void the warranty. The device must be connected only to a supply circuit that is protected by a Ground Fault Circuit Interrupter (GFCI). FAILURE TO CONNECT THIS DEVICE TO A GFCI SUPPLY CIRCUIT COULD RESULT IN ELECTRICAL SHOCK CAUSING SERIOUS BODILY INJURY, INCLUDING DEATH. WARNING - Disconnect all AC power during installation. 2
3 Safety Precautions (cont.) CAUTION - To prevent possible fire or electrical shock, use only replacement lamp specified by the manufacturer. A bonding lug is provided on the external surface. To reduce the risk of electric shock, connect the local common bonding grid in the area of the swimming pool, spa, or hot tub to these terminals with an insulated or bare copper conductor not smaller than 8 AWG US / 6 AWG Canada. Replace damaged cords immediately. Lamps and quartz sleeves are made of glass and are extremely delicate. Care should be taken when handling or replacing these components. Wear cotton gloves when handling lamps or sleeves. Hold bulbs by the ends only. Never touch the glass with bare hands. Wipe any fingerprints from lamps and sleeves with alcohol. CAUTION - this device is for swimming pool use only. Do not use this device for potable (drinking) water sanitization. DANGER - ULTRAVIOLET RADIATION. Disconnect Power Before Replacing Lamp. This device contains an ultraviolet lamp that can cause discomfort, irritation and damage to the eyes if viewing occurs while device is in operation. Prolonged exposure to the eyes can cause serious injury to the eyes, including blindness. DO T VIEW UV LAMP WHILE THE DEVICE IS IN OPERATION. 3
4 Table of Contents How HydroRite Works & Specifications Pg. 5-6 Installation: Pg Installation Overview & Parts Description 8-9 Venturi & Lamp Installation Vessel top & Connecting Control Box to Vessel PCB Overview & LED Indicators Maintenance: Pg UV Lamp Removal & Replacement Cleaning the Quartz Sleeve Troubleshooting: Pg UV Lamp Not Lit Power LED Not Lit Lamp/Ballast LED is Red Flow/Over Temp/Interlock LED Vessel Makes Noise or Leaking 33 Flow Charts Pg Frequently Asked Questions (FAQ) Pg
5 HydroRite: How It Works The Hayward HydroRite contains a high intensity electrically operated Ultraviolet (UV) lamps which is located inside the unit s wet chamber. The UV lamp emit light at two separate wavelengths within the UV spectrum; 254 nm and 185 nm. The 254 nm wavelength is called the germicidal wavelength. This wavelength is capable of inactivating a wide array of microorganisms such as bacteria, viruses, protozoa (e.g. Cryptosporidium and Giardia), algae spores and other single vesseled waterborne microbes. The 254 nm UV light alters the DNA and RNA of the microorganisms rendering them incapable of infection. The 185 nm wavelength, on the other hand, is called the ozone generating wavelength and is responsible for converting oxygen, contained in the quartz sleeve area, into ozone. The ozone created is introduced into the water stream using a venturi. Ozone, a strong oxidizer and bactericide in its own right, works together with the UV to oxidize bather waste and inactivate microorganisms utilizing a process known as advanced-oxidation. 5
6 Specifications & Head Loss HYD-UVO: Plumbing diameter: 2 inch Input Power: 120VAC, 60Hz Power Consumption: 0.8A Maximum Operating Pressure: 50 psi Operating Flow Range: gpm Maximum Flow Rate: 75 gpm Number of Bulbs: 1 Volume of Vessel:.75 gallon 6
7 HydroRite UVO 3 Installation and Overview
8 8 HydroRite: Installation Overview
9 HydroRite: Part Description Transformer 2 Fan 8 3 Ballast: Green LED = Ok Red LED = Error PCB 5 Vessel 5 6 Inlet Union 7 Outlet Union 8 Vessel lock nut 6 Fig. 1 Fig. 2 9
10 HydroRite: Venturi Ozone that accumulates in the UV lamp sleeve is introduced into the water stream using the venturi. 10
11 Vessel: Lamp Installation 11 Fig. 3
12 HydroRite: Vessel Top Fig. 4 12
13 HydroRite: Connecting Control Box to Vessel 1. Lamp and corresponding socket connector has a unique design (Fig.5). 2. Lower lamp into vessel (Fig. 6). 3. Socket fitting twists into place. 4. Connect UV sensor. Note: 7a represents the interlock cable AND 7b shows the interlock switch. 7a 7b Fig. 5 Fig. 6 Fig. 7 13
14 HydroRite: PCB Overview A B C D A Transformer Input (120VAC) E F G H B C D E F G H I 2X (1.25A) PCB Fuses PCB Input Power (120VAC) Transformer Output (240VAC) Input from Ballast (Operation Status) Output to Ballast Fan (12VDC) Output to LED Display (12VDC) Output to Ballast (240 VAC) Flow & Interlock Sensors (interchangeable) 14 I
15 HydroRite: LED Indicators Power On LED This green LED will be on under normal operation. Even when the pool pump is not running and HydroRite shuts off its lamp, the Power On LED will be lit. Lamp/Ballast LED This red LED indicator implies an issue with the lamp or ballast, or a problem with the connection from the ballast cable to the lamp. Note that the lamp has a defined life and will eventually need to be replaced. 15 Flow/Over Temperature/Interlock LED The HydroRite will shut down due to the following conditions: Flow - the LED indicates a no or low flow condition. Over Temperature - The HyroRite has a temperature sensor that will shut down operation to protect itself if high temperatures are sensed. This can be caused by high ambient temps & direct sunshine. Interlock - The LED indicates the vessel cap has not been installed properly OR the interlock connection is not properly made.
16 HydroRite UVO 3 Maintenance
17 UV Lamp Removal & Replacement 1. Unplug the device from the power outlet (Fig 8 & 9). 2. Shut off the circulation pump and make sure there is no pressure in the system. Then close the inlet and outlet valves on either side of HydroRite. 3. Drain the unit by unscrewing the threaded plug from the base of the vessel (Fig. 9 & 10). TE: If the Acid Wash system is plumbed, remove the hose to the shut-off valve from the base of the vessel. You can then open the valve to release the pool water. 4. Removing the Electrical Enclosure Cover by unscrewing the four screws (Fig. 12 & 13). 5. Remove the power clips from the Pressure switch and set cover aside. Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig
18 UV Lamp Removal & Replacement (cont.) 6. Remove the lamp by grasping the lamp connector and rotating counterclockwise to unlock the lamp from the nut (Fig. 14). 7. Once unlocked, slowly pull the lamp straight up and away from the quartz sleeve until it clears the vessel (Fig. 15). Carefully place the lamp(s) in a safe location while cleaning the quartz sleeve. Fig. 14 CAUTION: The UV lamp is sensitive to handling and should be allowed to fully cool before being moved. Wait at least 30 minutes after disconnecting power to begin the removal process. Fig
19 UV Lamp Removal & Replacement (cont.) 8. Slowly lower the new lamp(s) down into the quartz sleeve (Fig.16). Once you have verified that the lamp(s) are secured, reconnect the 4- Pin Connector (Fig. 17 & 18) to the pins on top of the lamp(s). TE: The ceramic 4-Pin Connector is designed to fit onto the end of the lamp in ONLY ONE ORIENTATION. Clean and re-lubricate the O-ring before reinstalling the enclosure cover. Fig. 16 Fig. 17 Fig Place the plastic electrical cover on the top of the HydroRite unit and tighten the screws using a Phillips screwdriver (Fig. 19 & 20). Plug in the power cord. Turn on the circulation pump, making sure to open any valves (if applicable) that were closed. Verify that the lamp is lit. Fig. 19 Fig
20 Cleaning The Quartz Sleeve: Automatic When using an automatic cleaner, the HydroRite s quartz sleeve can be cleaned with no need to disassemble the Cell Vessel. When the user initiates a cleaning, an acid bath will clean the quartz sleeve. The cleaner will be permanently plumbed into the system; connected to the inlet and outlet ports located on the top and bottom sides of the vessel. Muriatic Acid: Use a diluted mixture of 4 parts water to 1 part Muriatic acid (20º Baume hydrochloric acid 31.45% by weight). ALWAYS ADD ACID TO WATER, and do so slowly. Cleaning Procedure: 1. Shut off pool filter pump. 2. Close the two 3-way valves (page 5) to isolate the vessel from the pool system. 3. Open inlet and outlet port valves, if used. 4. Start the automatic cleaner and run the acid wash pump for no less than 30 minutes to fully clean the system. 20
21 Cleaning The Quartz Sleeve: Manually Cleaning Procedure: 1. Unplug the device from the power outlet (Fig. 21 & 22). 2. Shut off the circulation pump and make sure there is no pressure in the system. Then close the inlet and outlet valves on either side of HydroRite. 3. Drain the unit by unscrewing the threaded plug from the base of the vessel (Fig. 23 & 24). TE: If the Acid Wash system is plumbed, remove the hose to the shut-off valve from the base of the vessel. You can then open the valve to release the pool water. 4. Removing the Electrical Enclosure Cover by unscrewing the four screws (Fig. 25 & 26). 5. Remove the power clips from the Pressure switch and set cover aside. Fig. 21 Fig. 22 Fig. 23 Fig. 24 Fig. 25 Fig
22 Cleaning The Quartz Sleeve: Manually (cont.) 6. Use a soft clean cotton cloth (or cotton gloves) to remove the lamp(s) by grasping the lamp connector and rotating counter-clockwise to unlock the lamp from the nut (Fig. 27). 7. Once unlocked, slowly pull the lamp straight up and away from the quartz sleeve until it clears the vessel (Fig. 28). Carefully place the lamp(s) in a safe location while cleaning the quartz sleeve. CAUTION: The UV lamp is sensitive to handling and should be allowed to fully cool before being moved. Wait at least 30 minutes after disconnecting power to begin the removal process. TE: If you should touch the lamp with your bare hands, it can be cleaned with a soft cotton cloth and rubbing alcohol Fig. 27 Fig
23 Cleaning The Quartz Sleeve: Manually (cont.) 8. Remove the stainless steel sleeve from the top seal plate before moving on (Fig. 29 & 30). 9. Remove quartz sleeve by turning the locknut counter clockwise and removing (Fig. 31 & 32). Carefully clean both the inside and the outside of the quartz sleeve using N-ABRASIVE CLEANERS, as they can scratch the high quality glass. If lime or hard water calcium deposits are encountered, rinse the quartz sleeve with tap water, then clean with lime removal products such as Lime-A-Way using lint-free cloth. After using the lime removal products, rinse and wipe with alcohol. Completely dry the sleeve both inside and out before placing the UV lamp inside the quartz sleeve. 10. Carefully inspect the cleaned quartz sleeve for cracks. If any cracks in the quartz sleeve are found, the sleeve should be replaced. Broken quartz sleeve will allow water to enter the dry electrical chamber and attack the electrical components of the unit, which will cause them to fail. 23 Fig. 29 Fig. 30 Fig. 31 Fig. 32
24 Cleaning The Quartz Sleeve: Manually (cont.) 11. Slowly lower the lamp down into the quartz sleeve (Fig. 33). Once sleeve is secured (Fig. 34), reconnect the 4-Pin Connector to the pins on top of the lamp. TE: DO T touch the lamp with bare hands (Use included gloves). The ceramic 4- Pin Connector is designed to fit onto the end of the lamp in ONLY ONE ORIENTATION. Clean and re-lubricate the O-ring before reinstalling the enclosure cover. 12. Gently clean the UV Sensor using a non-abrasive cleaning solution and a soft cloth. 13. Place the plastic electrical cover on the top of the HydroRite unit and tighten the screws using a Phillips head screwdriver (Fig. 35). 14. Plug in the power cord. Turn on the circulation pump, making sure to open any valves (if applicable). Verify that the lamp is lit. 15. HydroRite should now be operational! 24 Fig. 33 Fig. 34 Fig. 35
25 HydroRite UVO 3 Troubleshooting
26 Step 1A 1. UV Lamp Not Lit Power LED status Verify ballast LED Step 1B If the power LED is lit proceed to 1B. If T, go to Step 2A, Power LED Not Lit. If LEDs are lit on the ballast proceed to 1C. If lit, jump to step 1D. Step 1C Check ballast input power Step 1D Green ballast LED lit 26 Verify VAC present on the PCB. If /LOW voltage replace PCB (GLX-HYDPCB). If correct, replace ballast (GLX-HYDBALLAST). If green ballast LED is lit, Replace lamp (GLX-HYD- LAMPUV). If not, proceed to step 1E.
27 Step 1E 1. UV Lamp Not Lit (cont.) Verify lamp connection Replace lamp Step 1F Inspect lamp connections & cable for damage, if damaged, replace cable (HYXSLACA). If not damaged, go to 1F. Power off, inspect quartz sleeve & replace lamp (GLX-HYD-LAMPUV). If this did not correct the problem go to 1G. Step 1G Replace ballast 27 Replace the ballast (GLX-HYDBALLAST).
28 Step 2A 2. Power LED Not Lit Verify source power Verify LED power Step 2B Verify source power ( VAC). If /LOW resolve incoming power. If correct go to 2B. Test for VDC on LED input. If /LOW go to step 2C, if OK contact support: Step 2C Check PCB fuses 28 Remove fuses and verify continuity. If open, replace fuse(s), if closed go to step 2D.
29 2. Power LED Not Lit (cont.) CAUTION: Transformer output is 240VAC! Step 2D Transformer output Step 2E Transformer input Verify Transformer output is VAC. If OK replace PCB (GLX-HYDPCB). If /LOW go to 2E. Verify Transformer input is VAC between pins 1-3 & 2-4. If OK replace transformer (GLX- HYDXFMR), if /LOW replace PCB (GLX-HYDPCB). 29
30 Step 3A 3. Lamp/Ballast LED is Red Verify lamp connection Verify lamp cable Step 3B Remove & reconnect lamp cable. If problem not solved go to step 3B. Inspect lamp cable for damage. If damaged replace cable (HYXSLACA). If not go to step 3C. Step 3C Replace lamp Step 3D Replace ballast 30 Power off, inspect quartz sleeve & replace lamp (GLX-HYD-LAMPUV). If LED is still ON go to 3D. Power off, replace the ballast (GLX-HYDBALLAST). Then reapply power.
31 Step 4A 4. Flow/Over Temp/Interlock LED Verify pump is on Inspect HydroRite vessel Step 4B 15GPM (MIN) Verify the pump is running. If it is not, turn the pump on and recheck. If ON go to step 4B. Verify water is passing through the vessel (15GPM MIN). If OK go to 4C. If not, resolve flow issue. Step 4C Check the filter Step 4D Unplug & inspect switches 31 Check filter, if cleaning is required, clean filter and recheck. If clean, go to step 4D. Unplug flow & interlock switches. If damaged replace (GLX-HYDMAN/GLX-FLO-RP), if not go to 4E.
32 4. Flow/Over Temp/Interlock LED (cont.) Flow switch Interlock switch Step 4E Step 4F If flow switch was not already swapped, replace flow switch (GLX-FLO-RP). If LED still ON go to 4F. If interlock switch was not already changed, replace (GLX-HYDMAN). If LED still ON go to 4G. Step 4G Contact support 32 The LED is still on due to a temperature related situation. Contact tech support (908)
33 Step 5A 5. Vessel Makes Noise or Leaking Verify vessel mounting Inspect top vessel o-ring Step 5B Step 5C Verify whether vessel is secured to pad. If not, secure vessel to pad. If secured, go to step 5B. Inspect quartz sleeve Step 5D Turn off pump, and inspect top vessel o-ring. If damaged, replace (SB2KIT). If Ok go to step 5C. Inspect drain plug 33 Inspect the quartz sleeve for damage. If damaged, replace (HYX2DQSA). If not, go to 5D. With pump off, inspect drain plug & o-ring. If damaged, replace (BSX1PLUG2).
34 1. UV Lamp Not Lit UV Lamp Not Lit Power LED ON? Are any LEDs lit on ballast Green ballast LED On? Replace lamp Jump to: Power LED Not Lit pg. 35 Check ballast input power. Verify lamp Connection Jump to Section B Replace PCB VAC present? Replace ballast Section B Connection correct? Lamp cable damaged? Replace lamp cable Fix lamp connection Replace lamp & inspect quartz sleeve Lamp lit? Problem solved Replace ballast 34
35 2. Power LED Not Lit Power LED Not Lit Verify source power VAC present? 10-12VDC present at LED connection? Contact Tech Support: (908) Resolve source power issue Check Fuses, Are fuses OK? Transformer output shows VAC? Replace bad Fuse(s) Jump to Section B Replace PCB Section B Both transformer inputs show VAC? Replace Transformer Replace PCB 35
36 3. Lamp/Ballast LED is Red Lamp/Ballast LED is Red Connection correct? Lamp cable damaged? Replace lamp cable Fix lamp connection Replace lamp & restart Lamp lit? Problem solved Replace ballast 36
37 4. Flow/Over Temp/Interlock LED Flow, Over Temp, Interlock LED Pump running? Water passing through vessel? (min 15gpm) Filter clean? Turn pump ON Resolve flow issue Clean filter Section B Unplug & inspect sensors Jump to Section B Damaged? Replace damaged switch(s) 37 Contact Tech Support: (908) Replace flow switch, did LEDs go out? Replace interlock switch, did LEDs go out? Problem solved
38 5. Vessel Makes Noise or Leaking Vessel Makes Noise or Leaking Vessel secured to pad? Top vessel o-ring intact? Quartz sleeve intact? Secure vessel to pad Replace o-ring Replace quartz sleeve Jump to Section B Section B Inspect drain plug Drain plug or o-ring damaged? Replace drain plug 38
39 HydroRite UVO 3 Frequently Asked Questions (FAQs)
40 FAQs Q. Is HydroRite compatible with ALL pool chemicals? A., except for a biguanide sanitizer. The strong oxidizing power of the HydroRite device will destroy the biguanide chemical, rendering the water a milky white color. Q. Is there any residual effect from UV? A., UV light is applied only to the water while it passes through the HydroRite vessel. For this reason, a chemical sanitizer such as bromine or chlorine is still required; however, the levels of these sanitizers can be reduced by as much as 75% over typical levels. Q. Is the HydroRite system designed for salt water use? A., all plastic components are compatible with pools equipped with Hayward Salt Chlorine Generator Systems. The stainless steel insert sleeve (if used) will slowly deteriorate in salt water. The sleeve can be replaced easily as it slides into the vessel. Q. Will use of a time clock shorten lamp life? A. MAYBE, Some shortening of the lamp life can be expected when the HydroRite unit is turned off and back on frequently. However, a daily on/off cycle will not create a major lamp life issue. Frequent on/off cycles should be avoided, however. For best lamp efficiency, the lamp should be replaced on yearly basis. 40
41 FAQs Q. Can the HydroRite unit be mounted horizontally? A., vertical mounting is required to maintain the proper flow dynamics inside the vessel for maximum exposure to the UV light. Also, the unit has been designed for maximum weather integrity of the electronics when mounted vertically. Q. Can multiple units be used together for larger systems? A., you can add any number of HydroRite units to a manifold system to allow for larger outputs and flow rates beyond the capacity of a single HydroRite unit. Contact Hayward to obtain a drawing showing the proper method of plumbing multiple HydroRites for larger applications. Q. Is there any residual effect from Ozone? A. No, the Ozone create by the HydroRite is injected into the plumbing in front of the vessel. After entering the HydroRite vessel, the UV light converts the Ozone to Hydroxyl radicals in a process called Advanced Oxidation. The Hydroxyl radicals are very short lived sanitizers/oxidizers that are used up before the water returns to the pool. Q. Do I need to turn HyroRite off when cleaning my filter? A. No, the flow sensing pressure switch that is part of your HydroRite unit will automatically shut the UV lamp off until proper flow inside the HydroRite vessel is re-established. Should you need to turn the HydroRite off, simply unplug the power cord from the power outlet. 41
HydroRite UVO3. 2 Residential UV/Ozone Sanitizing System. Owner s Manual. Contents. Model: HYD-UVO
092596 RevA HydroRite UVO3 2 Residential UV/Ozone Sanitizing System Owner s Manual Contents Safety Instructions...1 Before you Begin...2 Installation...3 Operation...7 Maintenance...7 FAQs...10 Troubleshooting...11
More informationUltraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL
Ultraviolet Systems Inc. UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL TABLE OF CONTENTS SECTION 1 General Information 1A. Description...1 1B. Specifications...1 SECTION 2 Installation 2A. Pool Preparation...
More informationHydroRite. 2 Commercial UV/Ozone Sanitizing System. Owner s Manual. Contents HYR2CSC-UVO
092555 RevD HydroRite 2 Commercial UV/Ozone Sanitizing System Owner s Manual Contents Safety Instructions...1 Before you Begin...3 Installation...4 Operation...8 Maintenance...12 FAQs...14 Troubleshooting...15
More informationREAD AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 IMPORTANT SAFETY INSTRUCTIONS Read the instructions The appliance is not to be used by persons (including children) with reduced physical, sensory
More informationPRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR
Installation and Operating Instructions FLOW AUTOMATIC REGULATOR SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS WARNING Risk of Electric Shock. Connect only to a branch circuit protected by a ground-fault
More informationOzone + UV Sanitation
Ozone + UV Sanitation Installation Manual 4-2177-01 Rev.C IMPORTANT SAFETY INSTRUCTIONS When installing and operating the DEL Spa Solar Eclipse, basic precautions should always be followed: READ AND FOLLOW
More informationSimplyClear Pressurized Filter Product Manual
SimplyClear Pressurized Filter Product Manual For Model: SimplyClear 1250 (Item #130040) Table of Contents: Important Information... 2 Package Contents... 3 Technical Specs... 3 How it Works.................................
More informationUltraviolet Water Sterilizer Installation and Maintenance Manual
Ultraviolet Water Sterilizer Installation and Maintenance Manual (Models:GP-UV6W, GP-UV12W, GP-UV55W) INSTALLERS: PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS SYSTEM. PERFORMANCE IS GUARANTEED
More informationREAD AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS International Patent #9,938,166 Patented Micro-Ozone cell ozone technology: Patent #8367007 1 IMPORTANT SAFETY INSTRUCTIONS Read the maintenance
More informationSUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION
SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION Thank you for selecting an Aqua Logic, Inc. Ultraviolet (UV) Sterilizer. Each model has been designed and built to provide years
More informationDEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL
DEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL C-M-P.COM 4-2535-01 Rev.B IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS WARNING: Risk of electric shock. Install at least 5 feet from
More informationVMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance
VMS-3 Part Number: 95-0031 Ultraviolet Systems VMS-3 Installation, Operation & Maintenance The following are the types of flags used in this technical manual. They designate safety related items and important
More informationNANO TECH UV-C DISINFECTION SYSTEM
NANO TECH UV-C DISINFECTION SYSTEM USER GUIDE MODELS NT-UV16 NT-UV40 and NT-UV40-T NT-UV75 and NT-UV75-T NT-UV87-TO (Ozone) NT-UV130F and NT-UV130-TF TABLE OF CONTENTS 1. Safety warnings... 3 2. Introduction...
More informationAllClear G2 Series Pressurized Filters Product Manual
AllClear G2 Series Pressurized Filters Product Manual For Models: AllClear G2 2000 (Item #130050) AllClear G2 3500 (Item #130051) AllClear G2 4500 (Item #130052) AllClear G2 4500 AllClear G2 3500 Table
More informationPRE INSTALLATION PROCEDURES
PRE INSTALLATION PROCEDURES DANGER! ELECTRICAL SHOCK HAZARD. Only qualified personnel who have read and understand this entire manual should attempt to install, or service this WL250 Water Treatment System,
More informationNext Generation Corona Discharge Installation & Operation Manual
Next Generation Corona Discharge Installation & Operation Manual 4-2319-01 Rev.A IMPORTANT SAFETY INSTRUCTIONS READ & FOLLOW ALL INSTRUCTIONS Read this manual completely before attempting installation.
More informationUV I UNIT030W / UV I UNIT055W
016W 030W / 055W 110W 220W UV Systems Assembly and Operating Instructions Water we re in our Element www.intewa.de Table of Contents 1. General Information... 2 2. Safety Precautions... 2 3. Dimensioning...
More informationBALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL
BALLAST REPLACEMENT INSTALLATION MANUAL WARNING Turn off power at main source before making any electrical connections or servicing the unit. UV light produced by this unit is harmful to the eyes and may
More informationOZONE SYSTEM FOR IN-GROUND POOLS New and Existing
INSTALLATION & OPERATIONS MANUAL FOR Z0-910/912 OZONE SYSTEM FOR IN-GROUND POOLS New and Existing MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 800-676-1335 4-0454-041900/03 IMPORTANT SAFETY
More informationInstructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)
02934-INS-SAVIO Rev.A Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers) Congratulations! Thank you for purchasing our 16, 25, or 57 Watt Retro-Fit
More informationUltraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual
Ultraviolet Monitoring System Part Numbers UV/MS-1 V3 UV/MS-2 V3 Installation And Operations Manual 2 System Description The Wyckomar UV Monitor measures true UV intensity at 254 nm, which is the effective
More informationSERVICE REQUIREMENTS
SERVICE REQUIREMENTS WARNING! Read and understand the contents of this manual before attempting to service WL270 Water Treatment System. Failure to follow the instructions in this manual could result in
More informationOzone Generator Systems
PZ2-4V - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear
More informationOzone Generator Systems
PZ2-1 & PZ2-2 - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal
More informationConduit ~15" Inlet. UV Sterilizer - Connection to Forcemain
6" Sch 40 PVC Housing Final Grade (slope to drain) Conduit ~15" Power Cord Length 25 (Standard Length) ~48" Outlet PVC Forcemain from Pump 40watt Disinfection Unit rated at: 60k microw/cm 2 @ 24gpm ~29"
More informationHP50HA ABG Heat Pump
HP50HA ABG Heat Pump Troubleshooting Guide Residential TSG-ABGHPa Copyright 2017 Hayward Industries Inc. Safety Precautions Warning! High Voltage Electrocution Hazard Hazardous voltage can shock, burn,
More informationSLT-Series Installation and maintenance instructions
Installation and maintenance instructions MODELS UVG SLT1, UVG SLT2, UVG SLT30, UVG SLT40, UVG SLT75, UVG SLT80, UVG SLT125, UVG SLT172 ATTENTION: Please read this manual carefully and follow the instructions.
More information* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.
SERVICE REQUIREMENTS WARNING! Read and understand the contents of this manual before attempting to service infiniti UV Water Treatment System. Failure to follow the instructions in this manual could result
More informationFOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.
FOR THE RECORD You should record the model and serial numbers, which can be found on the back of the unit, for future reference. Warranty: 18 mo. on unit and 1 year on check valve assembly Model: The Ozone
More informationEcoMaster - Residential Pools up to 40,000 Gallons
- Residential Pools up to 40,000 Gallons INSTALLATION/ OPERATION GUIDE Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear Water PROZONE Copyright 2018 Prozone Water Products: 3004 11 th
More informationINSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
More informationCHAMPION PUMP OWNER S MANUAL
CHAMPION PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions
More informationSERVICE REQUIREMENTS
SERVICE REQUIREMENTS WARNING! Read and understand the contents of this manual before attempting to service WL270 Water Treatment System. Failure to follow the instructions in this manual could result in
More information1020 Industrial Drive, Orlinda, TN fax
Operation Manual Ultraviolet Disinfection System 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2 Theory of Operation... 2 1.3
More informationInstruction Sheet DANGER
VIQUA Lamp and Quartz Sleeve Replacement Models: D4, E4, F4, D4 Premium, Plus Models Discontinued Models: A, B, C, D, E, F, B4, C4 Overview UV Lamp replacement: The amount of UV light created by the UV
More informationClear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual
Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual IMPORTANT SAFETY INSTRUCTIONS For Further Assistance Contact Us: 303.872.4477 support@clearcomfort.com
More informationOzone plus UV Sanitation System Installation & Operations Manual
Ozone plus UV Sanitation System Installation & Operations Manual 3580 Sueldo Street, San Luis Obispo, CA 93401 800.676.1335 o3info@delozone.com www.delozone.com 4-2305-01 Rev.B TABLE OF CONTENTS SECTION
More informationPRE INSTALLATION PROCEDURES
PRE INSTALLATION PROCEDURES DANGER! ELECTRICAL SHOCK HAZARD. Only qualified personnel who have read and understand this entire manual should attempt to install, or service this unit, failure to do so could
More informationModel CWA200 Owner s Manual
Model CWA200 Owner s Manual ClearWaveAir Purifier Owner s Manual Model CWA200 Thank you for purchasing the ClearWaveAir air purifier. The ClearWaveAir system will greatly improve the air quality in your
More informationUltraviolet (UV) Water Treatment System
water products Ultraviolet (UV) Water Treatment System Installation Instructions & Owner s Manual 12GPUV-55W, 24GPMV-110W, 32GPMV-165W, 48GPMV-220W CAUTION: Before using UV System, read this manual and
More informationINSTALLATION & MAINTENANCE
INSTALLATION & MAINTENANCE MODELS: UVG SLT 2 (GT7-2UVG) UVG SLT 30 (GT7-4UVG) UVG SLT 40 (GT7-8UVG) UVG SLT 75 (GT7-13UVG) UVG SLT80 UVG SLT125 (GT7-15UVG) and UVG SLT 172 Stainless Steel Water Disinfection
More informationPZ1, PZ3 & PZ6 Installation Guide
PZ1, PZ3 & PZ6 Installation Guide PROZONE INTERNATIONAL, INC. Ozone Water Purification Systems INSTALLATION GUIDE Prozone PZ1, PZ3 and PZ6 Series Ozone Generator Systems SAFETY READ AND FOLLOW ALL INSTRUCTIONS.
More informationECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL
ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all
More informationBased in the UK, Triogen is a world leading company with over twenty years experience in the design and manufacture of specialist Ozone and UV
UV and Ozone Based in the UK, Triogen is a world leading company with over twenty years experience in the design and manufacture of specialist Ozone and UV systems for domestic and commercial swimming
More informationWARNING WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS
AIR CLEANERS/ FILTERS 2001 Lennox Industries, Inc. Dallas, Texas USA 504,458M 07/2001 HEALTHY CLIMATE GERMICIDAL LIGHT INSTALLATION INSTRUCTIONS FOR LENNOX MODELS UVO3-500, UVO3-1000, UVO3-2000 General
More informationECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL
ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning
More informationPressurized Filter Up to 1250 gallons
Pressurized Filter Up to 1250 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. ITEM #FP1250UV Questions, problems, missing parts? Before returning to your retailer, call our customer service
More information2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP
2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP 8308 PUMP PARTS BREAKDOWN Ref # Part # Manf. # Descrip on 1 NEP2134 AC 81361 PUMP LID 2 NEP2135 AC 81396 PUMP LID
More informationAquaRite. Troubleshooting Guide Residential. TSG-AQR159d. Copyright 2017 Hayward Industries Inc.
AquaRite Troubleshooting Guide Residential TSG-AQR159d Copyright 2017 Hayward Industries Inc. Safety Precautions Warning! High Voltage Electrocution Hazard Hazardous voltage can shock, burn, cause serious
More informationSMF PUMP OWNER S MANUAL
SMF PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions
More informationI N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM
S a f e W a t e r T e c h n o l o g i e s, I n c. I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM UVR04 MODELS: 4 GPM, 1/2 INCH
More informationMODEL 7000 SUCTION UNIT
MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices
More informationMAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP
MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP 8104 MAXI-PUMP PARTS BREAKDOWN Re f # 1 2 3 4 5 6 7a 7b 8 9 10 11 12 13 14 15 16 2 Part # NEP2134 NEP2135
More informationUltraviolet Disinfection Unit Installation and Owners Manual
Ultraviolet Disinfection Unit Installation and Owners Manual (PLEASE KEEP FOR PERMANENT REFERENCE) READ THIS MANUAL This manual covers installation, operation, and maintenance requirements for models E,
More informationADVANCE Ultraviolet (UV) Water Treatment System
ADVANCE Ultraviolet (UV) Treatment System Installation Instructions & Owner s Manual GAUV-6S, GAUV-10S, GAUV-15S GAUV-12H, GAUV-20H, GAUV-32H CAUTION: Before using UV System, read this manual and follow
More informationEMPEROR SMART UV SYSTEMS UV STERILIZER
AQUATIC ECO-SYSTEMS EMPEROR SMART UV SYSTEMS UV STERILIZER INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL
More informationInstruction Sheet DANGER
VIQUA Lamp and Quartz Sleeve Replacement Models: D4, E4, F4, D4 Premium, Plus Models Discontinued Models: A, B, C, D, E, F, B4, C4 Overview UV Lamp replacement: The amount of UV light created by the UV
More informationWL380 QUICK START GUIDE
WL380 QUICK START GUIDE WARNING! Only trained and qualified technicians should attempt to install, maintain, or service Waterlogic equipment. Failure to follow all instructions in this manual could result
More informationSTEAMPRO. Steam Generator Troubleshooting and Service Guide
STEAMPRO Steam Generator Troubleshooting and Service Guide TABLE OF CONTENTS Page PREFACE... 1 I. STEAMPRO STEAM GENERATOR SYSTEM...2 II. PLUMBING AND ELECTRICAL...3-4 III. SYSTEM OVERVIEW... 5-10 IV.
More informationPZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series
PZ2 Series Manual PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems INSTALLATION GUIDE and OPERATION MANUAL Prozone PZ2 Series Ozone Generator Systems SAFETY READ AND FOLLOW ALL INSTRUCTIONS.
More informationA measured step forward
A measured step forward Operations & Maintenance Manual TM JESCO UV 405-412-440-450-480-550-80 2 LCD LCD PLUS Contents 1. Introduction...3 2. General Principles and Safety Instructions...4 3. Instructions
More informationOzone plus UV Sanitation System Installation & Operations Manual
Ozone plus UV Sanitation System Installation & Operations Manual 800.676.1335 o3info@delozone.com www.delozone.com 4-2305-01 Rev.D TABLE OF CONTENTS SECTION 1 General Information 1A. Description...1 1B.
More informationSERVICE REQUIREMENTS
SERVICE REQUIREMENTS WARNING! Read and understand the contents of this manual before attempting to service WL400. Failure to follow the instructions in this manual could result in death, serious personal
More informationPro-MAX Ultraviolet Sterilizer
Pro-MAX Ultraviolet Sterilizer Lifegard Aquatics introduces the Pro-MAX UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less
More informationImportant Safety Instructions
8 THE BUBBLE MIST STOPS COMING BACK INTO THE POOL: Note: Our suction side installation method requires a portion of the pump s power. Anything affecting the pump s performance affects our air draw. Under
More informationTIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL
TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6
More informationElite Primer Baldor Series External Pond Pump
Elite Primer Baldor Series External Pond Pump ( 5250PPB21, 6440PPB23, 7550PPB26, 9600PPB28) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS, READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS
More informationWAILEA OWNER S MANUAL
WAILEA OWNER S MANUAL The blades in each pack are matched for equal weight to assure smooth fan operation. If more than one fan is being installed, be careful not to mix blades from different cartons.
More informationSteril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:
Steril Air mobil Owner s Manual GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : +90212 244 4401 Fax: +90212 251 7136 SAFETY WARNINGS All personnel should be alerted to the potential hazards
More informationDRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information
INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -
More informationPATENTED APG OZONE CELLS DESTROYS HARMFUL CONTAMINANTS REDUCE CHEMICAL DEMAND
APG OZONE GENERATOR PATENTED APG OZONE CELLS DESTROYS HARMFUL CONTAMINANTS REDUCE CHEMICAL DEMAND c-m-p.com/del OZONE CREATES SAFER, CLEANER, CLEARER WATER THE ADVANTAGES OF OZONE Ozone systems provide
More informationWATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15
WATER UV STERILIZERS WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15 MANUAL Patent nr 204935-2012 - 2 User Safety! Warning This device may only be operated and installed by
More informationOwner s Manual READ AND SAVE THESE INSTRUCTIONS
16 Outdoor Misting / Oscillating Fan Model Number: AMMF16R-1 Owner s Manual READ AND SAVE THESE INSTRUCTIONS CAUTION: Before using this product, read this manual and follow all safety rules and operating
More informationUV Lamp and Quartz Sleeve Replacement/Maintenance
UV Lamp and Quartz Sleeve Replacement/Maintenance Models: Tap, Tap Plus, Home, Home Plus, Professional, Professional Plus (Excluding, D4, E4, F4, and Plus and Monitored versions) Overview UV Lamp replacement:
More informationAqua Ultraviolet UV Sterilizer Instruction Manual for SL Series Wiper Units
42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com Aqua Ultraviolet UV Sterilizer Instruction Manual for SL Series Wiper Units SEE INSIDE
More informationPRE-INSTALLATION PROCEDURE
PRE-INSTALLATION PROCEDURE Required with each BLUPURA Water Treatment System. 1 each External Filter 1 each Chiller 1 each CO 2 Regulator 1 each External Filter 1 each Water Pressure Regulator 1 each 4
More informationWEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S
INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT SERIES NO'S 1 2 4 Sold by: Manufactured by: WEDECO Ideal Horizons, Inc. 3520 Westinghouse
More informationQUIETFLO OWNER S MANUAL
QUIETFLO OWNER S MANUAL INSTALLATION, OPERATION & PARTS To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completley. CAUTION - We highly recommend a qualified
More informationAS-V/186K Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual
AS-V/186K Series Ultraviolet Disinfection Systems MODELS: AS-V 16 AS-V 26 AS-V 36 AS-V 38 AS-V 48 ATS-186K-10 ATS-186K-20 ATS-186K-40 ATS-186K-60 ATS-186K-80 ATS-186K-120 ATS-186K-240 ATS-186K-480 Installation,
More informationWARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS
AIR CLEANERS/ FILTERS 2001 Lennox Industries, Inc. Dallas, Texas USA 504,327M 07/2001 HEALTHY CLIMATE GERMICIDAL LIGHT INSTALLATION INSTRUCTIONS FOR LENNOX MODELS UV-500, UV-1000, UV-2000 General The Lennox
More informationPlease read this manual carefully before connecting and operating your COOL-AIR Evaporative Cooler.
Cool-Air 5051 Please read this manual carefully before connecting and operating your COOL-AIR Evaporative Cooler. Please read the "IMPORTANT SAFETY INSTRUCTIONS" at the beginning of this manual. ENGLISH
More informationModel K 520 M Part No
Model K 520 M Part No. 1.069-680.0 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents...
More informationGen II Entree Bath. Maintenance Manual. All Models. Important Safety Instructions Read & Follow All Instructions Thoroughly
Gen II Entree Bath All Models Maintenance Manual Important Safety Instructions Read & Follow All Instructions Thoroughly Note: The serial tag is at the first page of this manual package. The Standards
More informationPRE INSTALLATION PROCEDURES
PRE INSTALLATION PROCEDURES DANGER! ELECTRICAL SHOCK HAZARD. Only qualified personnel who have read and understand this entire manual should attempt to install, or service this unit, failure to do so could
More informationS-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:
UVG S440 MW UVG S160, S245 UVG S75, S40-76 S-Series Protect your water from pathogens and disease with the UV-Guard S-Series. The S-Series is a robust and dependable UV disinfection system able to provide
More informationOZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS
INSTALLATION & OPERATIONS MANUAL FOR ZO-900 OZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 800-676-1335 4-0449 Rev. A.- 052605 Copyright
More informationInstallation Guide. Manufactured for Aero-Spa, LLC Web:
Installation Guide Manufactured for Aero-Spa, LLC E-Mail: info@aero-spa.net Web: www.aero-spa.net For outdoor use only! WARNING Pool care and sanitizing is the sole responsibility of the owner. In some
More informationInstruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement
VIQUA UVMAX Lamp and Quartz Sleeve Replacement Models: H, K, H+, K+, PRO0, PRO0, PRO0 and PRO50 Overview Instruction Sheet UV Lamp replacement: The amount of UV light created by the UV lamp decreases over
More informationService Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800
Service Manual Model Number: Compact Fireplace DF203A DF2006 UL Part Number 6901860100 to 800 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to service this fireplace. For
More informationREGISTERED HANDBOOK. Document: ECN: Revision: C. MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models
REGISTERED HANDBOOK Document: 793612 ECN: 03-1884 Revision: C Checked by: OR_ Approved by: DK Date: 03DE08 Date: 03DE08 MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models TROJAN
More informationK 3.97 M. Specifications or visit our website: In USA call: Part No
K 3.97 M High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4-5 Operating Instructions... 5-6 GFCI Instructions... 6 Using the Accessories... 6 Working with
More informationInstallation and Operation Manual. ACF-18 Automatic Chlorinating Feeder
Installation and Operation Manual ACF-18 Automatic Chlorinating Feeder Operating Specifications Inlet Flow: 1.0-1.5 gpm Outlet Flow: = Inlet Flow Inlet Pressure: 10-45 psi Maximum Output: 26 lbs. of Available
More informationSchuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution
S168-544-OO1E REV.A Schuco byallied MEDICAL ASPIRATOR MnrInI -33OA USER'S MANUAL A Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by
More informationUV100E Ultraviolet Air Treatment System
UV100E Ultraviolet Air Treatment System OWNER S GUIDE U.S. Registered Trademark Copyright 2001 Honeywell Inc. All Rights Reserved 69-1442- 1 HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM WORKS When installed
More informationAEM EASY DRUM M A N U A L
AEM EASY DRUM M A N U A L 1 D A A2 A1 B 2 E H K1 I F K2 J G 2 3 L Z Q N O P M 4 M S R V E X Y (2x) W (5x) U H K1 I F K2 J G 3 TERMS OF USE 1. Build in height: Water level equal to bottom drain channel
More informationVacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA
OzoneAX 3 T Vacuum-ultraviolet Ozone Systems Installation & Operation anual odel OZ-SPA A. Important Safety Instructions IPORTANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety
More informationInstallation & Operating Guide
5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase
More informationUser s Information Manual
User s Information Manual Gas-Fired Storage Water Heater, Tankless Water Heater, Heating Appliance, and Combination Appliance Models IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
More informationuv and ozone for commercial pools
uv and ozone for commercial pools principles benefits In addition to filtration, swimming pools need the following Triogen s design expertise in each technology brings about treatments: the following benefits:
More informationModel K 240 plus Part No
Model K 240 plus Part No. 1.223 585.0 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 GFCI Instructions... 6 Using the Accessories...
More information