ASME STANDARDS IN MODEL CODES

Size: px
Start display at page:

Download "ASME STANDARDS IN MODEL CODES"

Transcription

1 STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A Air Gaps in Plumbing A Air Gap Fittings For Use With Plumbing, Appliances and Appurtenances A Stainless Steel Drainage for Sanitary DWV, Storm, and Vacuum Applications, Above and Below- Ground A Macerating Toilet and Related Components A Water Heater Relief Valve Drain Tubes A Water Closet Personal Hygiene Devices A A Withdrawn in 2009 A A M A Plastic Fittings For Connecting Water Closets to the Sanitary Drainage System Point of Use and Branch Water Sub-Metering Manually Operated Quarter- Turn Shutoff Valves for Use in Plumbing Floor Affixed Supports for Offthe-Floor Plumbing For Public Use Framing Affixed Supports for the Off-the-Floor Water Closets with Concealed Tanks ) NR NR NR 2004

2 A A Name Floor and Trench Drains 2007 Roof, Deck and Balcony Drains Model Code With Year of Referenced IPC IRC UPC 2009 NSPC NR 2007 A DRAFT Hydrants A DRAFT Expansion Joints A Enameled and Epoxy Coated Cast Iron and PVC Plastic Sanitary Floor Sinks 2007 NR 2007 A DRAFT Trench Drains A A A A Syphonic Roof Drain 2005 NR 2005 Backwater Valves Grease Interceptors NR 2004 Grease Removal Devices 2007 A FOG (Fats, Oils & Greases) Disposal A / B125.1 A / B125.2 NR NR NR NR Plumbing Supply Fittings Plumbing Waste Fittings

3 A A / B125.6 A Name Performance Requirements for Backflow Devices and in Plumbing Fixture Fittings Model Code With Year of Referenced IPC IRC UPC 2009 NSPC 2009 Flexible Water Connectors 2009 Withdrawn in Deck Mounted Bath/Shower Transfer Valves A In-Line Sanitary Waste Valves for Plumbing Drainage A Protectors/Insulators for Exposed Waste and Supplies on Accessible A / B45.2 A / B45.1 A / B45.4 A A / B45.15 A A / B Enameled Cast Iron and Enameled Steel Plumbing 2004 NR NR NR NR Ceramic Plumbing Stainless Steel Porcelain Enameled Formed Steel Plumbing Flush Valves and Spuds for Water Closets, Urinals, and Tanks Hydraulic Performance Requirements for Water Closets and Urinals Hydromassage Bathtub NR NR NR NR NR

4 Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A Superseded by APSP-16 Suction Fittings for Swimming and Wading Pools, Spas, Hot Tubs and Whirlpool Bathtub Appliances NR NR NR 2007 A Non-Vitreous Ceramic Plumbing NR 1991 A Dual Flush Devices for Water Closets A DRAFT Penalware and Special Use A Wall Mounted and Pedestal Mounted, Adjustable and Pivoting Lavatory and Sink Carrier NR NR A A Electrohydraulic Water Closets NR NR NR 2007 Six-Liter Water Closets Equipped with Dual Flushing Device A Bathtubs/Whirlpool Bathtubs with Pressure Sealed Doors NR NR A Withdrawn Terrazzo Plumbing A Manufactured Safety Vacuum Release (SVRS) For Residential and Commercial Swimming Pool, Spa, Hot Tub and Wading Pool Suction A Vitreous China Nonwater Urinals 2005 NR NR NR NR

5 A A A A Redesignated A Roof, Deck, & Balcony Drains A M A WITHDRAWN A M 1991 Name High Purity Piping Firestops and Devices for Piping Residential Fire Sprinkler Model Code With Year of Referenced IPC IRC UPC 2009 NSPC Roof Drains 1983 NR NR 1983 Hydrants for Utility and Maintenance Use NR NR Water Hammer Arresters Cleanouts 1991 NR (R) Legend NR = Not Referenced Revised: 11/25/2013 by A. Guzman

PLUMBING FIXTURES CHAPTER 27

PLUMBING FIXTURES CHAPTER 27 CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,

More information

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS 19.1 REFERENCED STANDARDS Referenced Standards Chapter 19 Table 19.1 lists the standards that are referenced within the requirements of this Code. Table 19.1 shows the designation number of the standard,

More information

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Ohio Administrative Code Rule Number OPC Section IPC origin Reason for proposed 4101:3-2-01 Alternate on-site 2015 Added definition

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#58619/Page 1/November 1, 2017 PLUMBING Executive Summary: Presently, the Plumbing Systems serving the building are cold water, hot water, sanitary, waste and vent system, storm drain piping, and natural

More information

MATERIALS Traps TRAPS. No. IPC IRC Description

MATERIALS Traps TRAPS. No. IPC IRC Description MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture

More information

1 Exam Prep Plumber s Handbook Tabs and Highlights

1 Exam Prep Plumber s Handbook Tabs and Highlights 1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first

More information

2012 UPC STANDARDS TASK GROUP

2012 UPC STANDARDS TASK GROUP 2012 UPC STANDARDS TASK GROUP The scope of this task group is to review standard cross-references within the body of the 2009 Uniform Plumbing Code and Table 14-1. The objective is to update standards

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN CHAPTER 14 STANDARDS Note: Referenced sections will be updated before publishing. 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and

More information

Mechanical Inspection Plumbing

Mechanical Inspection Plumbing 0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,

More information

Sanitary Drainage Systems

Sanitary Drainage Systems 11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed

More information

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A vent stack handling 25 dfu s with a developed length of 35 feet shall be inches minimum

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING Test Code: 5924 Version: 01 Specific competencies and skills tested in this assessment: Safety Follow rules for fire safety Follow rules for housekeeping

More information

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION................1 101.0 Title, Scope, and General...........1 101.1 Title............................1 101.2 Purpose.........................1 101.3 Plans Required...................1

More information

PLUMBING REQUIREMENTS

PLUMBING REQUIREMENTS PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all

More information

STANDARDS TASK GROUP REPORT

STANDARDS TASK GROUP REPORT STANDARDS TASK GROUP REPORT THE SCOPE OF THE STANDARDS TASK GROUP INCLUDES ADDING CROSS- REFERENCES TO TABLE 14-1 AND RECOMMEND WHERE SUCH REFERENCES ARE APPLICABLE TO THE REFERENCED STANDARDS AND TO UPDATE

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the

More information

1 Exam Prep Plumbing State Contractors Practice Exam 2

1 Exam Prep Plumbing State Contractors Practice Exam 2 1 Exam Prep Plumbing State Contractors Practice Exam 2 1 According to Chapter 64E-6, when sizing a grease interceptor used in a restaurant, the correct formula is. A. (S) x (EW 12) x (LF) B. (S) x (GS)

More information

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type. PART 1 - GENERAL 1.1 Toilet rooms and utility rooms to have floor drains at lowest point. 1.2 Utilize Exposed Flushometers. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION.............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

2015 MPC, MMC and IFGC Significant Changes

2015 MPC, MMC and IFGC Significant Changes 2015 MPC, MMC and IFGC Significant Changes Based on the 2015 Michigan Plumbing Code, (MPC), the 2015 Michigan Mechanical Code (MMC) and the 2015 International Fuel GaS Code (IFGC) Purpose This program

More information

TABLE OF CONTENTS. Part I Administrative... 1

TABLE OF CONTENTS. Part I Administrative... 1 Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103

More information

Test Code: 8117 / Version 1

Test Code: 8117 / Version 1 Pennsylvania Customized Assessment Blueprint Plumbing Technology/Plumber PA Test Code: 8117 / Version 1 Copyright 2012. All Rights Reserved. General Assessment Information Plumbing Technology/Plumber PA

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point. PART 1 - GENERAL 1.01 Toilet rooms and utility rooms to have floor drains at lowest point. 1.02 Utilize Exposed Flushometers. 1.03 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

More information

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code ProVent Systems Plumbing Fundamentals Educational Literature Comparison of ProVent Design Rules and The International Plumbing Code Guide to Contents Topics and Descriptions Page Interior views of the

More information

CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use

CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 14-1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment

More information

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

WATER HAMMER ARRESTORS & MISC. SPECIALTIES TABLE OF CONTENTS Pictorial Index Water Hammer Arrestors Certification Sizing & Placement Backwater Valves Typical Installations Trap Seal Primers Compliance Pressure & Flow Characteristics Typical Installations

More information

PLUMBING INSTALLATIONS

PLUMBING INSTALLATIONS PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...

More information

Plumbing and Drainage

Plumbing and Drainage Dufferin-Peel Catholic District School Board STANDARD TEXT FOR Plumbing and Drainage for ELEMENTARY AND SECONDARY SCHOOLS Prepared by the Plant Department Formatted by the Design Department THE INFORMATION

More information

2015 IPC, IMC and IFGC Significant Changes

2015 IPC, IMC and IFGC Significant Changes Accreditation 2015 IPC, IMC and IFGC Significant Changes Based on the International Plumbing Code (IPC ), the International Mechanical Code (IMC ) and the International Fuel Gas Code (IFGC ) The International

More information

Plumbing Technology/Plumber CIP Task Grid

Plumbing Technology/Plumber CIP Task Grid 1 Secondary Task List 100 DEMONSTRATE PERSONAL SAFETY IN THE TRAINING LABORATORY 101 Follow rules for fire safety. 102 Follow rules for housekeeping safety. 103 Follow shop rules. 104 Follow rules for

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

2009 IPC ,IMC Q &A ANDIFGC

2009 IPC ,IMC Q &A ANDIFGC 2009 IPC,IMC ANDIFGC Q &A TABLE OF CONTENTS PREFACE.... ix ABOUT THE INTERNATIONAL CODE COUNCIL...x IPC CHAPTER 1 SCOPE AND ADMINISTRATION...1 Section 101 General... 1 Section 102 Applicability... 1 Section

More information

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

1. Division 22 Section Emergency Plumbing Fixtures. 2. Division 22 Section Drinking Fountains and Water Coolers. Page 224000-1 SECTION 224000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 11: Sanitary Appliances Phase 2

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 11: Sanitary Appliances Phase 2 Trade of Plumbing Module 2: Domestic Hot and Cold Water Service Unit 11: Sanitary Appliances Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 2 Domestic

More information

CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1

CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1 CHAPTER 14 MANDATORY REFERENCED STANDARDS AHAM DW-1-92 Household Electric Dishwashers Appliances AHAM DW-2PR-92 Plumbing Requirements for Household Dishwashers Appliances AHAM FWD-1-92 Food Waste Disposers

More information

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)* CHaPTeR 10 TRaPS and INTeRCePTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

DOMESTIC WATER PACKAGED BOOSTER PUMPS

DOMESTIC WATER PACKAGED BOOSTER PUMPS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot

More information

Matrix of changes for the National Standard Plumbing Code July 2013

Matrix of changes for the National Standard Plumbing Code July 2013 Matrix of changes for the National Standard Plumbing Code July 2013 Item # Section Number Person Submitting Change Committee Action 10-77 10.20.8 and Table 3.1.3 XI Certification 10-82 12.16 Size and Lengths

More information

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION PC 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. The minimum air gap for a fixture with an effective open of 1/2", located away from a

More information

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES City of Los Angeles Department of Building and Safety MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES November 21, 2017 Part I: Approved Listing Agencies Part II: Approved Testing

More information

Plumbing Fixtures CEU 251. Continuing Education from the American Society of Plumbing Engineers. September ASPE.

Plumbing Fixtures CEU 251. Continuing Education from the American Society of Plumbing Engineers. September ASPE. Plumbing Fixtures Continuing Education from the American Society of Plumbing Engineers September 2017 ASPE.ORG/ReadLearnEarn CEU 251 READ, LEARN, EARN Note: In determining your answers to the CE questions,

More information

Plumbing Fixtures CEU 216. Continuing Education from the American Society of Plumbing Engineers. October ASPE.

Plumbing Fixtures CEU 216. Continuing Education from the American Society of Plumbing Engineers. October ASPE. Plumbing Fixtures Continuing Education from the American Society of Plumbing Engineers October 2014 ASPE.ORG/ReadLearnEarn CEU 216 READ, LEARN, EARN Note: In determining your answers to the CE questions,

More information

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2 CHAPTER 10 TRAPS AND INTERCEPTORS < 1001.0 Traps Required. Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.1, shall be separately trapped by an approved type

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR EARLY-CLOSURE REPLACEMENT FLAPPERS OR EARLY-CLOSURE REPLACEMENT FLAPPER WITH MECHANICAL ASSEMBLIES IAPMO

More information

PLUMBING CURRICULA OUTLINE

PLUMBING CURRICULA OUTLINE PLUMBING CURRICULA OUTLINE CORE CURRICULUM 2015 Basic Safety (Construction Site Safety Orientation) (12.5 Hours) (Module ID 00101-15) Presents basic jobsite safety information to prepare workers for the

More information

2009 IRC. and Fuel gas Provisions

2009 IRC. and Fuel gas Provisions 2009 IRC Q &A Plumbing, MechanICAl and Fuel gas Provisions TABLE OF CONTENTS PREFACE... vii ABOUT THE INTERNATIONAL CODE COUNCIL...viii PLUMBING PROVISIONS... 1 CHAPTER 25 PLUMBING ADMINISTRATION....3

More information

APPENDIX J ILLUSTRATIONS

APPENDIX J ILLUSTRATIONS The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely

More information

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.0 General. 2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.1 Applicability. This chapter shall govern the materials, design, and installation of indirect waste piping, receptors, and connections; and

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter. 201.2

More information

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY a. Only potable water shall be supplied to plumbing fixtures used for drinking, bathing, culinary use or the processing of food, medical or pharmaceutical

More information

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES City of Los Angeles Department of Building and Safety MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES July 25, 2018 Part I: Approved Listing Agencies Part II: Approved Testing

More information

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures PART 1: GENERAL A. This Section provides design standards for plumbing fixtures and trim. Certification of compliance with specified ANSI, UL, and ASHRAE Standards will be required, as appropriate, for

More information

WARRANTY POLICY & RECOMMENDED MAINTENANCE

WARRANTY POLICY & RECOMMENDED MAINTENANCE WARRANTY POLICY & RECOMMENDED MAINTENANCE WARRANTY POLICY The following information will explain the plumbing components and warranty coverage for the plumbing systems and fixtures in your new home. It

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION Quality Products & Value Packages Residential Solutions FIRE PROTECTION COMFORTSUSTAINABILITYCONTROL PRESSURE REGULATORS TRENCH DRAINSHVAC SYSTEMS SAFETY ANTI-SCALE SYSTEMS HEATING & COOLING CONTROLS PLUMBING

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES CSUEB Pioneer Heights Phase r 15410 Page 1 SECTION 15410 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION SECTION 224100 - RESIDENTIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

B. Shop Drawings: Include diagrams for power, signal, and control wiring. SECTION224213.13 -COMMERCIAL WATERCLOSETS PART 1- GENERAL 1.1 SUMMARY Section Includes: 1. Water closets. 2. Flushometer valves. 3. Toilet seats. 1.2 ACTION SUBMITTALS Product Data: For each type of product.

More information

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Pipe Sizing Table. Hydraulic Load Served (fixture units) MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3

More information

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010 General: 1) (Q) Who enforces the cutting and notching requirements found in the plumbing code? (A) The plumbing inspector would question the contractor initially. A building inspector would either take

More information

PLUMBING FIXTURES Reserved

PLUMBING FIXTURES Reserved CHAPTER 27 PLUMBING FIXTURES Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 395R This page left intentionally blank. 396R 2003 INTERNATIONAL RESIDENTIAL CODE SECTION P2708 SHOWERS P2708.1 General. Shower

More information

DOCUMENT TABLE OF CONTENTS

DOCUMENT TABLE OF CONTENTS DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026

More information

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point. PART 1 - GENERAL 1.01 Toilet rooms and utility rooms to have floor drains at lowest point. 1.02 Utilize Exposed Flushometers. 1.03 Utilize wall hung toilet room fixtures. Urinals for handicapped may be

More information

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

B. Shop Drawings: Include diagrams for power, signal, and control wiring. SECTION 224213.13 - COMMERCIAL WATER CLOSETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X X

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X X CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 10 - TRAPS AND INTERCEPTORS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority

More information

2012 Virginia Plumbing Code & VRC (Plumbing) Update Training

2012 Virginia Plumbing Code & VRC (Plumbing) Update Training 2012 Virginia Plumbing Code & VRC (Plumbing) Update Training ----------------------------- Henrico County Department of Building Construction and Inspections Introduction This presentation was prepared

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 22 40 00 Plumbing Fixtures 1. General A. Definitions 1. Section includes a. Water closets and urinals b. Lavatories, sinks, and service sinks c. Electric water coolers, drinking fountains, d. Showers

More information

Bill de Blasio, MAYOR. build safe live safe. Rick D. Chandler P.E., COMMISSIONER

Bill de Blasio, MAYOR. build safe live safe. Rick D. Chandler P.E., COMMISSIONER E LAA limited alteration application - FILING GUIDE information you need to know Bill de Blasio, MAYOR build safe live safe Rick D. Chandler P.E., COMMISSIONER FIXTURES COMMENTS efile Backflow Preventer

More information

A. Section Joint Sealants: Seal fixtures to walls and floors.

A. Section Joint Sealants: Seal fixtures to walls and floors. SECTION 224000 - PLUMBING FIXTURES PART 1 GENERAL 1.1 SECTION INCLUDES A. Water closets. B. Urinals. C. Lavatories. D. Sinks. E. Service sinks. F. Showers. G. Wash fountains. H. Eye wash fountains. 1.2

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE SCHEDULE OF S Penalty Fees. The fee for construction work performed before securing permit(s), where required, may be charged a fee of TWO TIMES THE COST OF THE PERMIT (S). Building Fee Schedule Residential

More information

Special Requirements For Health Care Facilities

Special Requirements For Health Care Facilities Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE 1. BUILDING FEES: 1 AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE ESTABLISHMENT OF FEES PURSUANT TO N.J.A.C.

More information

NEW WATER CONNECTION PROCEDURES

NEW WATER CONNECTION PROCEDURES NEW WATER CONNECTION PROCEDURES For Lincoln, Jerome, Village of Sanford WATER DISTRICT NO. 1 of MIDLAND COUNTY Office Location: 246 E. Price Rd. Midland, MI 48642 Mailing Address: PO Box 320 Sanford, MI

More information

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock. Plumbing Plumbing may be defined as practice, materials, and fixtures used in the installation, maintenance, and alteration of all piping, fixtures, appliances, and appurtenances in connection with sanitary

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter. 201.2

More information

Denotes a new question! Denotes a revised/revisited question. September 2009 General:

Denotes a new question! Denotes a revised/revisited question. September 2009 General: General: 1) (Q) What does a contractor/permit holder have to supply for an inspection? (A) Section 107.2 of the NC Administrative Code states that it is the duty of the permit holder to provide access

More information

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA AMERICAN PLUMBING INSTITUTE 2015 33 CONTINUING EDUCATION PO Box 31131 Spokane, WA 99223-3018 www.apiceu.com 2009 UPC Definitions Code Course 4 hours Course # ID09143 (CODE) DISCLAIMER NOTE: This course

More information

Comprehensive Inspection Agency (CIA) RESIDENTIAL & COMMERCIAL FEE SCHEDULE

Comprehensive Inspection Agency (CIA) RESIDENTIAL & COMMERCIAL FEE SCHEDULE (CIA) RESIDENTIAL & COMMERCIAL FEE SCHEDULE Phone: 570-573-28251 Fax: 570-385-3010 Page 1 of 7 Phone: 570-573-2825 CIA Fax: 570-385-3010 RESIDENTIAL FEES BUILDING / MISCELLANEOUS Plan Review $ 0 New Construction,

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Backwater valves. 2. Cleanouts. 3. Floor

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

Virginia Residential Code

Virginia Residential Code 2015 Virginia Residential Code 2015 Virginia Residential Code First Printing: September 2018 ISBN: 978-1-60983-846-1 COPYRIGHT 2018 by INTERNATIONAL CODE COUNCIL, INC. ALL RIGHTS RESERVED. This 2015 Virginia

More information

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING PLUMBING FIXTURES.

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING PLUMBING FIXTURES. ICC-ES Report PMG-1095 Reissued 08/2017 This report is subject to renewal 08/2018 EVALUATION SUBJECT: WATER CLOSET,VITREOUS CHINA WATER CLOSET WITH DUAL FLUSH DEVICE, VITREOUS CHINA LAVATORIES, VITREOUS

More information