CLASSIC. SIDE CABINET Installation Instructions
|
|
- Tracey Sharp
- 5 years ago
- Views:
Transcription
1 CLASSIC SIDE CABINET Installation Instructions
2 THIS MANUAL IS FOR AUTHORIZED AND QUALIFIED INSTALLATION PERSONAL ONLY! Table of Contents General Information...3 CCS Overview...4 CCS Cabinet Dimensions...5 CSD Overview...6 CSD Cabinet Dimensions...7 Preparing The Site...8 Cabinet Installation Door & Drawer Adjustment...13 Tapmaster Faucet Service Information...14 Air & Water Quick Disconnects...15 Dimensional Data Drawings...16 Installation and Servicing Checklist...17 Technical Support Technical assistance is available Monday through Friday, 8:00 am to 6:00 pm (Eastern Standard Time). Phone: Fax:
3 REV 0, 03/ REV 0, 03/11 General Information Definitions of Symbols The following symbols may be used throughout the product manual: IEC Symbols CAUTION: Failure to carefully follow the described procedure may result in damage to the equipment. WARNING: Failure to carefully follow the described procedure may result in damage to the equipment and the operator. Risk of electrical shock present. Make sure power is disconnected before attempting this procedure. The following symbols conform to IEC labeling standards and may be located throughout the product. AC (Alternating Current) Protective teeth (Ground) Attention: Consult accompanying documents OFF ON Type B equipment (Protected against electrical shock) Equipment Disposal Contact your local authorized dealer for proper disposal of the device to ensure compliance with your local environmental regulations. Interference with Electromedical Devices To guarantee the operational safety of electromedical devices, it is recommended that the operation of mobile radio telephones in the medical practice or hospital is prohibited. Strong EMI sources such as electro surgery units may affect performance. If performance problems occur, move the unit to another electrical circuit or physical location. Incompatible Units or Accessories To guarantee the operational safety and function of this device, the use of unapproved unit or accessories is not advised. Doing so could result in potential hazard. Obtaining Technical Literature The manufacturer will make available on request circuit diagrams, component parts lists, descriptions, calibration instructions or other information that will assist technical personnel to repair and replace serviceable items. CAUTION: Only authorized service technicians should attempt to service this equipment. Use of other than authorized technicians will void the warranty. Product Identification This cabinet can be identified by its product label, located underneath the midsection front panel. This label states the unit model and serial number, electrical specifications and safety classification. Note the sample label shown below: Dangerous voltage Manufacturing Date Waste Electrical and Electronic Equipment Technical Description Model Designation: Pelton Classic Side Cabinet MN SN OPERATORY CABINET (115VAC, 12A, 60Hz) CSD MO YR IEC Type B, Class 1 Listed to: UL Listed to: CAN/CSA C22.2 NO M MN SN OPERATORY CABINET (115VAC, 12A, 60Hz) CSS MO YR IEC Type B, Class 1 Listed to: UL Listed to: CAN/CSA C22.2 NO M Power Supply: CSD 120V ~50Hz, 15A Service CSS No electrical Protection against harmful ingress penetration of water: ordinary equipment Mode of operation: CSD Continuous CSS N/A Thank you for purchasing your new cabinet. It is engineered to provide many years of reliable performance. However, a certain amount of care is required. Conscientious adherence to the Maintenance Instructions will ensure that your unit will function to your satisfaction for many years to come. Therefore, we have provided you with a set of technical literature, which may be kept for quick and easy reference. In order to protect your rights under the warranty, the purchaser must register the unit by filling in the warranty information provided. Safety Notes This cabinet is not used in rooms where an explosion hazard exists. The pre-installation of the facility must be performed in accordance with the requirements outlined in our Pre-installation instructions. As the manufacturer of cabinetry, we can only assume responsibility from the safety related performance of the cabinet, if maintenance and repair are carried out by the manufacturer, or by agencies authorized by Pelton & Crane for this purpose, and if needed components affecting the safety of the appliance are replaced exclusively by original spare-parts. We suggest that you request a certificate stating the type and extent of the work performed, from those performing such work, if necessary stating any alterations of the rated parameters or operating ranges, as well as date, name of organization and signature. This type of appliance is classified to UL , EN , certified to CSA C22.2 No M90. Due to legal regulations, alterations of the cabinet, which could impair the safety of the operator, patient, or third parties, are not lawful! For reasons of product safety, only original Pelton & Crane accessories approved for this product, or accessories by third parties, which have been approved by Pelton & Crane, may be used. Using non-approved accessories is at the risk of the user. In order to prevent injury to persons and damage to the equipment, you must also read the warning and safety notes given in this User s Manual. These are emphasized with WARNING, CAUTION and NOTE. 3
4 CCS Overview H F G D E C A B A, sink and waste module B-C, storage module D, sink E, counter top F, waste container G, faucet H, soap dispenser 4
5 CCS Overview The CCS cabinet provides a work surface and storage. It is designed with the Dentist and staff in mind to provide a robust working enviroment for the daily activities of performing dentistry. This product is intended for use by dental professionals. CCS Cabinet Dimensions 18-1/8" 62" 32" 36" 12" 20" 28" 5
6 CSD Overview G H D F A B C A, sink and waste module B-C, unit mount area D, sink F, waste G, faucet H, soap dispenser 6
7 CSD Overview The CSD cabinet provides a work surface, storage, and can be installed with or without a Pelton & Crane delivery system. The CSD cabinet is designed with the Dentist and staff in mind to provide a robust working enviroment for the daily activities of performing dentistry. This product is intended for use by dental professionals. CSD Cabinet Dimensions 18-1/8" 62" 32" 36" 28" 31-1/2" 7
8 Preparing the Site WARNING: Always lift cabinets by bottom edge, being careful to lift with your legs and not your back. CAUTION: Make all required, air water and drain attachments from the utilities to the incoming stub up connections before the delivery system installation occurs. Doing so prevents damage to the utility lines from heat associated with some plumbing connection methods. Turn main power OFF at the installation site. WARNING: All Electrical wiring should be in accordance with local codes. WARNING: To avoid risk of electrical shock this equipment must be connected to power mains with protective earth. NOTE: Use floor template to locate utilities in relation to the dental chair. Because of varying city plumbing and electrical codes, the dealer should ensure that installation meets local requirements. Pelton & Crane can not be responsible for an installation which does not meet local plumbing and electrical codes. Select the location for cabinet that will meet the operator s arm reach and storage requirements. Refer to the dimensional drawings while considering the location of air, water and electrical connections. SPECIFICATIONS (Floor Template depicted in Illustration) Air & Water Shut-off Valves (If required for delivery) : 1/2 pipe N.P.T. (supplied by the contractor) protruding 1 from floor or wall. Manual shut-off valve supplied by the dealer to be installed by the contractor. Maximum height can not exceed 5 when valves are fully opened. Electrical: 1/2 conduit and quad box or equal junction (supplied by the contractor). Wire box as per code with top of the box no higher than 4 1/2 above finished floor. Voltage: 120 Volts AC, 3 wire, 15 amp circuit. Central Vacuum (if required): Plumbing should be specified and terminated in treatment column with 5/8 OD tube perpendicular to floor, similar to drain connection. Floor Template (CSD62-3 Shown) 62" 23" 21" 19" 15" BACK SIDE OF CABINET 12" 6" 8" OUTLINE OF SUBBASE OUTLINE OF CABINET 12" 10" 9" 8" 7" 6" 5" COLD WATER ELECTRICAL (OPTIONAL) VACUUM (OPTIONAL) HOT WATER DRAIN AIR (OPTIONAL) UTILITIES CHASE TO CHAIR (OPTIONAL) 18" UTILITIES CHASE To 12:00 CABINET (OPTIONAL) END OF CABINET 25" 8
9 Preparing the Site (Cont d) NOTE: The template illustration depicts the mounting points. 1. Lay installation template over plumbing stub-ups and check the distance from the cabinet to the walls according to operatory layout. (Floor template is depicted in illustration. Stub-up information in the template illustration applies to all models.) 2. The shut-off valves for air and water must be installed above the finished surface as indicated in the template: 5 max. when in an open position. 3. Install air and water shut off valves. NOTE: A 3/8 compression fitting is recommended for the output connection on the cutoff valves. 4. Connect flexible hoses from air and water regulator assemblies to the air and water shut off valves. NOTE: To ensure proper operation of the unit, flush air and water lines before connecting equipment. Place floor mounting bracket over the template. WALL ELEVATION NOTE: Will need to cut back cabinet wall when installing utilities from the wall. Allow 16" of 1/2" Flex Conduit to extend beyond stub-up for electrical hook-ups. 2" ELEC. BOX (Optional) Elec. Vacuum 2" Water Air N O 2 O 2 Finished Floor Surface 4-1/2" 7" 9" 11" 13" 15" 9
10 Cabinet Installation 1. Remove packaging from side cabinet. Before installing the side cabinet inspect the cabinet for damage and that all items on the quick install package checklist are in the packaging. Remove drawers and unclip doors. Set aside in a safe area until they are to be reinstalled. 2. Remove screws and boards securing side cabinet to the pallet. Carefully lift and slide side cabinet off the pallet and into position. ALWAYS lift the cabinet by the bottom edge, being careful to lift with your legs and not your back. DO NOT LIFT USING COUNTERTOP! Remove panels Remove screws and boards securing side cabinet to pallet 10
11 Cabinet Installation (Cont d) 3. Using a level on the counter top, level the side cabinet using the leveling feet as shown. Level Countertop Leveling Feet Leveling Feet Re-Install panels after leveling feet 4. Then measure down 1-1/2 from the inside of the module top and fasten the cabinet to the wall with (2) 2-1/2 #10 screws as shown. Install (2) 2-1/2 #10 screws into studs in the back wall 11
12 Cabinet Installation 5. Install water faucet and soap dispenser into the module top according to the manufacturer installation instructions. Install faucet and soap dispenser 6. Connect side cabinet plumbing according to local codes and test. 7. Re-install doors removed previously, taking care to place them in their original positions. Re-install doors 12
13 Door & Drawer Adjustment Cam wing mounting plate Note: Upper & lower plates must be moved together for each door Range (5/32") One piece wing plate Note: Upper & lower plates must be moved together for each door Range (5/32") WARNING over-adjusting hinges can cause damage Rotate front screw to increase or decrease door position. Range (3/32") Rotate spiral -tech cam screw to adjust door position. Range (3/16") Drawer front adjustment - Standard /3. 5. Horizontal Adjustment 1. Loosen Mounting Screws 2. Adjust Front 3. Tighten Screws Vertical Adjustment 4. Loosen Attachment Screw 5. Turn clockwise to raise - counter clockwise to lower, re-tighten Attachment Screw. 6. Tilt adjustment (for large drawers only) 1. 2/3. 4. Horizontal Adjustment 1. Loosen Mounting Screws 2. Adjust Front 3. Tighten Screws Vertical Adjustment 4. Loosen the attachment screw. Adjust drawer front up/down then tighten screw. 13
14 Tapmaster Faucet Service Information SYMPTOMS CAUSE REMEDY Tapmaster leaking and/or noise problems in valve blocks. (Note: Tapmaster uses a differential pressure principle to close. Do not set faucet handle at a trickle). These symptoms are generally caused by water borne debris lodged in the valve block porting and/or damage to the diaphragm from this debris. Tapmaster warranty does not cover damage or failure by water borne debris. In most situations, depending upon accessibility, debris may be removed from the valve blocks without removing them from the water lines. Shut off the water supply and disassemble the valve blocks by removing the 6-32 socket head screws (hint: remove screws halfway and tap to unseat valve block halves). Clean all ports of any foreign matter with particular attention to the main inlet ports (3 of circular group of 6). If no debris is found it will be necessary to remove the blocks from the lines and the 1/8 MPT x 3/8 tube inlet fittings to permit complete access. Take care not to lose the spring, filter disc and O-ring. After inspecting and cleaning the inlet port reinstall, in order, the O-ring, filter disc (smooth side against O-ring) and spring as per figure 2. Reinstall the inlet fitting with Teflon tape or thread sealant (do not over tighten). Inspect diaphragms for punctures and/or severe abrasions and replace if necessary. Reassemble the valve blocks making certain to orient the control tubing half of each block as per figure 1. If the above procedure fails to correct the problem, test the 3-way pilot valve for leaks and if necessary replace or return entire Tapmaster assembly to Integra for service. For infield service, order Tapmaster rebuild kit P/N 4001 from Integra Dynamics, Inc. INTEGRA DYNAMICS, INC. 20 Bedwood Road N.E. Calgary, Alberta Canada T3K 2K4 TEL: or FAX:
15 Air & Water Quick Disconnects Tools needed: 1/4 inch sleeve tool 1. Umbilical tubing: Run panel s umbilical tubing s into cabinet utility supply. ¼ Blue - Water supply ¼ Yellow Air supply 2. Water and Air Supply: Adjust regulated air to 80 psi and regulated water to 40 psi. 3. Quick Disconnects: Not supplied Water ¼ QD: Use DCI part # 0014 with shut-off or DCI part # 0015 without shut-off. Air 3/8 QD: Use DCI part # 0012 with shut-off or DCI part # 0013 without shut-off. Operating instructions: The air on-off toggle controls air to the 3/8 air quick disconnect. It is located on front of the panel on the left. The water flow control knob controls water to the ¼ water disconnect. It is located on the front of the panel on the right. Auxiliary Panel Cleaning and Maintenance Do not use powdered cleansers, scouring pads on this unit. Dental Unit Water Line Maintenance The Center for Disease Control and the American Dental Association can provide recommendations on when to flush your system, for how long, and what products to use. 15
16 Dimensional Data Drawings 62" 62" 30" CCS62-3 CCS " 62" 62" CSD62-3 CSD " 50" CSS50-3 CSS " 30" CSS30-3 CSS
17 Verify the following after installation or servicing of the cabinet: All manuals are present. All labels are present and legible. No mechanical damage on new installations. The cabinet is connected to the correct power source. There are no water or air leaks. All the cabinet adjustments have been made according to the users manual. Ensure control panel functions properly. Installation and Servicing Checklist 17
18 Notes 18
19 19
20 Pelton & Crane Fruehauf Drive Charlotte, NC USA 2011, Pelton & Crane We reserve the right to make any alterations which may be due to any technical improvements Order No Rev. 0, 04/11 Printed in USA
CLASSIC. CENTER ISLAND CABINET Installation Instructions
CLASSIC CENTER ISLAND CABINET Installation Instructions THIS MANUAL IS FOR AUTHORIZED AND QUALIFIED INSTALLATION PERSONEL ONLY! Table of Contents General Information...3 CCD72 Delivery Cabinet Overview...4
More informationClassic Twelve O clock Cabinet Installation Instructions
Classic Twelve O clock Cabinet Installation Instructions CF36 CF42 THIS MANUAL IS FOR AUTHORIZED AND QUALIFIED INSTALLATION PERSONEL ONLY! Table of Contents General Information... 3 CF36 Cabinet Overview...
More informationInstallation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 800-GECARES or visit our website at: www.geappliances.com BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT
More informationBuilt-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be
Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these instructions completely and carefully.
More information54, 63 Round Sink / Storage Unit Installation
54, 63 Round Sink / Storage Unit Installation Applies to Models: OSC054R, OSC063R Special Tools: Level 1/4 deep well socket Caulking Gun Belt Sander OSC054R-L (Shown) DA2172i OSC054R-R (54 RH Round Sink
More informationInstallation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
More informationDISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:
DISHWASHER Models DW2432 and DW2432SS Installation Manual Write Serial Number (on inner door of unit) here: Felix Storch, Inc. Summit Appliance Division 770 Garrison Avenue Bronx, New York 10474 www.summitappliance.com
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationInstallation Manual PS-225 & PS-275
Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal
More informationInstallation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324
Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324 To prevent accidents, which could cause serious injury or death, as well as machine damage read these instructions before installation
More informationMASTERPIECE /THERMADOR PROFESSIONAL SERIES BUILT-IN OVEN
MASTERPIECE /THERMADOR PROFESSIONAL SERIES BUILT-IN OVEN Built-in oven Four encastré Horno empotrado Table of Contents... 4 Table de Matières...19 Contenido...35 Models/Modèle/Modelo ME301JP ME301JS ME302JP
More informationInstallation Instructions Built-In Dishwasher
RINSE CHINA CRYSTAL SPEED CYCLE NORMAL WASH COOK WARE SELECTIONS ANTI BACTERIA START RESET ENHANCEMENTS DELAY HOURS ADDED HEAT PRE WASH HEATED DRY TO LOCK CONTROLS PRESS HEATED DRY FOR 3 SECONDS GE Consumer
More informationInstallation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 800-944-9400(US),800-245-8352(Canada)or visit our website at: www.frigidaire.com BEFORE YOU BEGIN Read these instructions completely
More informationViking Installation Guide
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at
More informationSAVE THESE INSTRUCTIONS
Built-In Dishwasher Dishwashers Write the model and serial numbers here: Model # Serial # You can find them on the tub wall just inside the door or. the lower part of back. Installation Instructions DDW1802W
More informationDishwasher Installation Manual
Dishwasher Installation Manual DW 51600 SS DW 51600 FBI DWT 51600 SS DWT 51600 FBI DWT 81800 FBI DWT 81800 SS DWT 81800 SSIH DWT 81800 SSWS DWT 52600 WIH DWT 52600 SSIH DWT 52600 BIH DWT 52800 WIH DWT
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationInstallation Manual PS-200 & PS-201
Installation Manual PS-200 & PS-201 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal
More informationDishwasher Installation Instructions DW 24XT/DW 24XV
Dishwasher Installation Instructions DW 24XT/DW 24XV Installation Instructions Dishwasher BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Observe all governing codes and ordinances.
More informationInstallation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)
Installation Viking Range, LLC Front Street Greenwood, Mississippi 890 USA (66) 455-00 For product information, call -888-845-464 or visit the Viking Website at vikingrange.com U L C U L 4 Series Built-In
More informationTop Control Dishwasher
INSTALLATION GUIDE Top Control Dishwasher NS-DWH2BS8/NS-DWH2SS8/NS-DWR2BS8/NS-DWR2WH8/NS-DWR2SS8 Before using your new product, please read these instructions to prevent any damage. Contents Introduction......................................................................................................
More informationInstallation Instructions Renaissance Built-in Dishwasher
Installation Instructions Renaissance Built-in Dishwasher Models RDW24S and RDW24I Part No. 105671 Rev. D Table of Contents Important Safety Instructions... 1 About Safety Instructions...1 Safety Symbols
More informationWater Boilers ME10EN, ME15EN. Table of Contents
Water Boilers ME10EN, ME15EN Operator Manual Model ME15EN Model ME10EN Safety Information...2 Rough-In Drawing...3 Installation...4 Priming...5 Cleaning...5 Table of Contents Adjustments...6 Maintenance...7
More informationDOUBLE DISHDRAWER TM DISHWASHER
DOUBLE DISHDRAWER TM DISHWASHER DD4DDFT & DD4DVT models INSTALLATION GUIDE US CA 5985 A 08.7 SAFETY AND WARNINGS! WARNING! Electrical Shock Hazard Before installing the dishwasher, remove the house fuse
More informationI<enmore Elite. instructions dlnstallation. Installation Guide Instrucciones de Instalaci6n. English / Espafiol/Frangais
Installation Guide Instrucciones de Instalaci6n instructions dlnstallation English / Espafiol/Frangais Models/Modelos/Mod_les: 630.1390% 630.1 391_ I
More informationEquipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions
Dry Assembled Elbows MUST Glue when Installed Exhaust Connection P-Trap Must Be Installed to Exhaust or Warranty will be Voided AA2360 Refer to this Manual for installation Instructions 2011 Midmark Corp.
More informationInstallation Instructions Built-In Dishwasher
GE Consumer & Industrial Appliances Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these
More informationDISHWASHER INSTALLATION INSTRUCTIONS
DISHWASHER INSTALLATION INSTRUCTIONS IMPORTANT! Read all of these instructions before installing the dishwasher. AUTOMATIC HIGH LOOP The drain hose is fastened to the back of the machine at the best height.
More informationInstallation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
More informationNATURAL GAS CONVERSION KIT
NATURAL GAS CONVERSION KIT Model # 498425 For use with Char-Broil RED Series Grills Only. FOR OUTDOOR USE ONLY This Natural Gas Conversion Kit can be used ONLY with Dual Fuel grills. WARNING CALIFORNIA
More informationInstallation Instructions Dual Fuel Ranges
Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you
More informationDISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE
DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE COVE DISHWASHER Contents 3 Cove Dishwasher 4 Specifications 7 Door Panel 9 Installation 15 Troubleshooting Features and specifications
More informationInstruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System
Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance
More informationArtizan Ortho-Pedo Bench Installation / User Manual
Artizan Ortho-Pedo Bench Installation / User Manual Applies to Models: PB250-L PB250-R Special Tools: Level 3/8 Masonry drill bit 9/32 Wood drill bit Language of origin: English vv If applicable, Midmark
More informationElectrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit
Installation Parts and Tools Parts not Provided Electrical cable Water supply tube Fittings for tube Coupler Teflon tape Air gap Wire nuts for 6-gauge wiring Hose clamp ⅞" UL approved strain relief Electrical
More informationPerformer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install
Installation Instructions Performer Cuspidor (For Performer III Chair & International Performer I Chair) You Will Need Adjustable wrench or 9/16" open-end wrench Magnetic leveling device 3/16" hex key
More informationPowerVac G Single to Twin Conversion Kit [ ]
PowerVac G Single to Twin Conversion Kit [002-1371-00] warning Motors are thermally protected with automatic reset. Unit may start without warning. Caution Vac unit weighs 375 lbs (170 kgs). Use care when
More informationInstallation Instructions
Installation Instructions Electric Drop-In Range JDS28, JDP39 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN Read these instructions carefully and completely.
More informationGen II Entree Bath - All Models
Gen II Entree Bath - All Models Installation Manual Important Safety Instructions Read & Follow All Instructions Thoroughly Important safety instructions. Read and follow all instructions thoroughly. CAUTION:
More informationInstallation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets
Installation Operation Maintenance Troubleshooting Version Dec/17 Mobile Cabinets Table of Contents WARRANTY... 3 Important Information... 4 Technical Specifications... 4 Weight & Dimensions... 5 Dimensions...
More informationINSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2
INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2 Publication No. 01906 Revision 0 Printed in Canada 1.1 INTRODUCTION
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ActiveSmart Slide-in refrigerator RS90A and RS90AU models NZ AU GB IE EU AE HK SG IN www.fisherpaykel.com 839137 A 02.15 R600a 1 safety and warnings This refrigerator contains
More informationRK-02 Multi Point Detector Operator s Manual
65-2485RK-02 Multi Point Detector Operator s Manual Part Number: 71-0237RK Revision: A Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationP/N CC-100. Coolant Circulator. Operation manual
P/N 4411-0019 CC-100 Coolant Circulator Operation manual Manual Version 1 Revision B July 1, 1998 Table of Contents Chapter 1 Introduction... 5 Description...5 Specifications...5 Chapter 2 Warnings...
More informationInstallation Instructions
Installation Instructions Self-Cleaning Radiant Electric Drop-In Range JDP47, JD968, JD900 If you have questions, call 1.800.GE.CARES or visit our website at: ge.com Before You Begin Read these instructions
More informationDESIGN CLASS FUNCTION
PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR PERFORMER SLIDE-IN COOK TOPS MODEL NUMBERS: AROBSCT-424, AROBSCT-242GD, AROBSCT-24X2GR, AROBSCT-430, AROBSCT-636, AROBSCT-436GD, AROBSCT-436GR,
More informationRK Multi Point Detector Operator s Manual
65-2480RK Multi Point Detector Operator s Manual Part Number: 71-0198RK Revision: C Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before
More informationSEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL
SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL This manual is provided as a guide to installation. All installations must comply with any and all local and national electrical
More informationInstallation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.
Important Information Page 2 Installation and Operation Manual 445 Procedures Cart Installation Page 3 Description Page 5 Components Overview Page 6 Controls & Indicators Page 7 Operation Page 8 HOT Operator
More informationOUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS
OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS IMPORTANT! Read all of these instructions before installing the dishwasher. AUTOMATIC HIGH LOOP The drain hose is fastened to the back of the machine at the
More informationWM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis
WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com
More informationModel HC-2. Crathco Whipped Hot Chocolate Dispenser. Table of Contents. Operation and Instruction Manual. for
Crathco Whipped Hot Chocolate Dispenser Operation and Instruction Manual Table of Contents Introduction...1 Specifications...2 Installation and Start-Up Procedures...2 How to Dispense Hot Chocolate...3
More informationSINGLE DISHDRAWER TM DISHWASHER
SINGLE DISHDRAWER TM DISHWASHER DD4SA & DD4SCT models INSTALLATION GUIDE US CA 595B 08.7 SAFETY AND WARNINGS! WARNING! Electrical Shock Hazard Before installing the dishwasher, remove the house fuse or
More informationInstallation Instructions Outdoor Refrigerator
Installation Instructions Outdoor Refrigerator For use with models: OF24LS, OF24RS Part No. 103609 Rev. C All specifications subject to change without notice. Dacor assumes no liability for changes to
More informationGE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH
GE Monogram Installation Instructions Stainless Steel Bottom Mount Built-In Refrigerators Models ZICS36N RH ZICS36N LH Before you begin - Read these instructions completely and carefully. IMPORTANT - Save
More informationOPERATING AND INSTALLATION MANUAL
OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against
More informationInstallation Instructions Induction Cooktop
Installation Instructions Induction Cooktop Models: RNCT304 and RNCT365 Part No. 107240 Rev. A Table of Contents Important Safety Instructions... 1 Important Information About Safety Instructions... 1
More informationCL1000 Ceiling Light OWNER S MANUAL. Marus Fruehauf Drive Charlotte, NC USA
CL1000 Ceiling Light OWNER S MANUAL Marus 11727 Fruehauf Drive Charlotte, NC 28273 USA Warranty The Marus Light was thoroughly inspected and tested in accordance with rigid specifications and standards
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION
Series 61 Low Water Cut-Off Typical Applications: - Primary or secondary low water cut-off for hot water and steam boilers. - Low water cut-off - High water cut-off - Alarm actuator OPERATION Maximum Boiler
More informationOPERATING AND INSTALLATION MANUAL
OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against
More informationINSTANT-FLOW C-MICRO WATER HEATER
WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS (LOW ACTIVATION MODELS) TABLE OF CONTENTS Technical Information..................................... 2 Dimensional Data........................................
More informationDESIGN CLASS FUNCTION
PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR MEDALLION DUAL FUEL RANGES MODEL NUMBERS: ARR-304DF, ARR-366DF, ARR-364GDDF, ARR-364GRDF, ARR-486GDDF, ARR-486GRDF, ARR-4822GDDF, ARR-484X2GRDF,
More informationWhole House Filter Model: WH-LD
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Save manual for future reference Whole House Filter Model: WH-LD! WARNING Please read carefully before proceeding with installation. Your failure to follow
More informationCascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions
Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions PENNER PATIENT CARE, INC Box 523 / 101 Grant St. Aurora, NE 68818 560750 Revision A 12/11/15 1-866-PENNERS
More informationPenner Stationary Patient Lift Safe Operation & Daily Maintenance Instructions
Penner Stationary Patient Lift Safe Operation & Daily Maintenance Instructions PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 350751 Rev B 09/15/2006 1-866-PENNERS 1-866-736-6377 1-800-732-0717
More informationINSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2
INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01900 Revision 2 Printed in Canada 1.1 INTRODUCTION Thank you
More informationRK Carbon Monoxide Transmitter Operator s Manual
65-2335RK Carbon Monoxide Transmitter Operator s Manual Part Number: 71-0177RK Revision: 0 Released: 4/12/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationAVANI Grinding Booth
AVANI Grinding Booth GB-6066-DD Customer: Kelly Walsh Customer PO#: 11305 AVANI SO#: Serial #: 153920-153921 Ship Date / Install Date: Tested By: Please read and save these instructions. Read carefully
More informationI<enmore Elite. instructions d'lnstallation. Installation Guide Instrucciones de Instalaci6n. English / EspaioJ / Frangais
Installation Guide Instrucciones de Instalaci6n instructions d'lnstallation English / EspaioJ / Frangais Models/Modelos/Mod_les: 630.1395 _ I
More informationTABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationSERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250
SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081305-01 Date 10/08 Introduction IOD150,IOD200,IOD250
More informationDishwasher. Installation manual DW60M9990AP
Dishwasher manual DW60M9990AP DW9000M_DD68-00197B-00_EN.indd 1 6/1/2017 4:34:14 PM Contents Contents 3 What s included 3 requirements 7 Dimensions and specifications 9 Step-by-step installation 11 2 English
More informationOVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS
OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS CSA Model98900 DRS02403 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas:
More informationLow Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers
Low Water Cutoff (LWCO) IQ Option Card p/n 102711-01, 102714-01 for Hot Water Boilers Instruction Sheet 102-360 APPLICATION The Low Water Cutoff (LWCO) IQ Option Cards are advanced, microprocessor based
More informationDESIGN CLASS FUNCTION
PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR LEGACY BUILT-IN ELECTRIC,GAS AND HYBRID SINGLE AND DOUBLE WALL OVENS MODEL NUMBERS: GAS MODELS: AROFG-30, AROSG-30, AROFFG-230, AROSSG-230,
More informationImPress IRONING STATION
CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-73 ImPress IRONING STATION Model LFB2611L JOB AID Part No. 8178203 FORWARD This Whirlpool Job Aid, ImPress Ironing Station, (Part No. 8178203), provides
More informationInstallation Instructions
Dear customer! Thank you for choosing this quality product from ASKO. We hope it will meet your expectations and fulfil your needs for many years to come. Scandinavian design combines clean lines, everyday
More information2-Stage Under Counter Filtration System Model: WP-2 LCV
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Save manual for future reference 2-Stage Under Counter Filtration System Model: WP-2 LCV IMPORTANT If you are unsure about installing your WATTS water filter,
More informationHelpful Tip: NOTE:
Grounded electrical supply required. Do not run drain lines, water lines or electrical wiring where they can interfere with or contact dishwasher motor or legs. The location where the dishwasher will be
More informationDOUBLE DISHDRAWER TM DISHWASHER
DOUBLE DISHDRAWER TM DISHWASHER DD4DI, DD4DTI & DD4DHTI models INSTALLATION GUIDE US CA 5986 A 08.7 !! WARNING! Electrical Shock Hazard Before installing the dishwasher, remove the house fuse or open the
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS TM DishDrawer dishwasher DD4D 7 & DD4DT 7 models US CA 59004D 04.3 FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL STANDARD HEIGHT DOUBLE MODELS TALL HEIGHT DOUBLE MODELS
More informationInstallation Instructions Built-In Dishwasher
GE Consumer & Industrial Appliances Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com STOP BEFORE YOU BEGIN Read
More informationINSTANT HOT WATER DISPENSER
INSTANT HOT WATER DISPENSER Tank Installation Materials required (not provided) 2 mounting bracket screws (and 2 plastic anchors if attaching to drywall) Shut-Off valve and T fitting Components When you
More informationInstallation Instructions
Installation Instructions If you have questions, call 800.626.2000 or visit our website at: www.monogram.com Automatic Icemaker ZDI15 ZDIS15 Design Guide with BEFORE YOU BEGIN Read these instructions completely
More informationAqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions
Aqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 350745 Rev F 02/23/11 1-866-PENNERS 1-866-736-6377 1-800-732-0717 E-mail
More informationInstallation Guide. Pedicure Spa D K-163, K-1006, K-1011, K-1012
Installation Guide Pedicure Spa K-163, K-1006, K-1011, K-1012 1063564-2-D Important Information WARNING: When using electrical products, basic precautions should always be followed, including the following:
More informationViking Installation Guide
Viking Installation Guide Viking Range, LLC Front Street Greenwood, Mississippi 890 USA (66) 55-00 For product information, call -888-85-6 or visit the Viking Web site at vikingrange.com Professional Freestanding
More informationSuperior Spa with Aqua-Aire
Superior Spa with Aqua-Aire Safe Operation & Daily Maintenance Instructions PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 350750 Rev H 08/28/2014 1-866-PENNERS 1-866-736-6377 1-800-732-0717
More informationINSTALLATION GUIDE Dual Fuel Ranges
INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel
More information30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
United States INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR
More informationA m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u
A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y Rev 2/15 D a n s e r e a u (8 0 0 ) 423-5657 / WWW.DHPDENTAL.COM CUSTOMER SUPPORT INF ORMATION Dansereau Health Products, Inc. has been manufacturing
More informationMIX Boiler & Font Range Service Manual
MIX Boiler & Font Range Service Manual 1000870# 1000871# 1000875# 1000880# 1000887# 1000878 1000879 2300268 www.marcobeveragesystems.com Ireland Tel: +353 (1) 295 2674 UK Tel: +44 (0207) 2744577 Service
More informationIns t a l l a t i o n In s t r u c t i o n s Wa r m i n g Ov e n For use with models: EW, EWO MW, MWO PW, PWO IWO, IOWO
Ins t a l l a t i o n In s t r u c t i o n s Wa r m i n g Ov e n For use with models: EW, EWO MW, MWO PW, PWO IWO, IOWO Part No. 65034 Rev. K Important Safety Instructions...1 Design Specifications...2-3
More informationELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING FOR YOUR SAFETY:
More informationRK Hydrogen Sulfide Transmitter Operator s Manual
65-2331RK Hydrogen Sulfide Transmitter Operator s Manual Part Number: 71-0176RK Revision: B Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction
More informationModel 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9001EXP Alarm No. 2080203(24)
More informationCONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS
CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-71 SinkSpa JETTED SINK Model LJD1306L JOB AID Part No. 8178201 FORWARD This Whirlpool Job Aid, SinkSpa Jetted Sink, (Part No. 8178201), provides the
More informationViking Installation Guide
Viking Installation Guide Viking Range Corporation Front Street Greenwood, Mississippi 890 USA (66) 55-00 For product information, call -888-VIKING (85-6) or visit the Viking Web site at vikingrange.com
More informationMaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S
Limited Warranty Global Medical Holdings (GMH) warrants the MaxiCompressor for 1 year from the date of purchase due to faulty parts or workmanship. This warranty is limited to the original purchaser of
More informationCombustible Gas Sample-Draw Detector Operator s Manual
35-3001-01 Combustible Gas Sample-Draw Detector Operator s Manual Part Number: 71-0282RK Revision: A Released: 8/3/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More information