MINE VENTILATION EQUIPMENT

Size: px
Start display at page:

Download "MINE VENTILATION EQUIPMENT"

Transcription

1 MINE VENTILATION EQUIPMENT

2

3 Fans for main ventilation of mines, shafts and production facilities of industrial enterprises Fans for main ventilation of mines, shafts and production facilities of industrial enterprises ВОД-16ПБ (VOD-16PB) Axial fan meant for ventilation of mines and pits with an equivalent orifice m 2. In fan installation air stream reversal is executed via change of impellers rotation without using bypass channels and shaft doors system. The fan provides 64-73% of direct work flow volume. ВОД-21Б (VOD-21B) Axial double-stage reversible fan meant for main ventilation of coal and ore mines, requires up to 120 of supplied air at 356 MPa pressure. This fan can also be used in ventilation systems, intended for handling of air and non-aggressive gases, of the companies belonging to the other branches of industry. The fan is designed according to a counter-rotation scheme. It consists of two rotors, a case, a collector, a spinner and a diffuser. The rotors are carried by SKF bearing units with grease lubricant. Equipped with two electric drive motors and two disk brakes. Steady operation limit at K reserve = 1.2 Fan wheel diameter, m 1,6 Flow volume (at peak point of efficiency), Static efficiency, % 79 Power of electric motor, kw 160 Rotational frequency, rpm Air stream reversal is carried out by change of electric drive motor rotational direction with a simultaneous change of vanes angle of intermediate guide vanes and straightener blades by accordingly. As reversal takes place, supply of 60-70% of direct flow volume is provided. The fan can be used either for suction, or for blowing ventilation. Fan structure includes the rotor with two impellers, straightener blades, guide vanes mechanism, a collector and a diffuser. Fan wheel diameter, m 2,1 Flow volume (at peak point of efficiency), Static efficiency, % 82 Power of electric motor, kw 450 Voltage, V 6000 Rotational frequency, rpm Static pressure, dapa (total power of two motors) rotational frequency 985 rpm Static pressure, dapa Limits at fan reversal and system resistance margin R=1.2 in relation to steady operation limit rotational frequency 750 rpm head-capacity characteristic at normal operation at reverse operation with 6 second stage impeller blades removed 1. Weight of rotor rotating parts is 570 kg 2. Inertia moment of one rotor is 105 kg*m 2 3. *Dimensions for reference 4. **Weight is indicated without regard to electric motor weight 1. Weight of rotor rotating parts is 2200 kg 2. Inertia moment of one rotor is 575 kg*m 2 3. *Dimensions for reference 4. **Weight is indicated without regard to electric motor weight 4 5

4 Fans for main ventilation of mines, shafts and production facilities of industrial enterprises Fans for main ventilation of mines, shafts and production facilities of industrial enterprises ВОД-40Б (VOD-40B) Axial double-stage reversible fan meant for main ventilation of large coal and ore mines. ВОД-50Б (VOD-50B) Axial double-stage reversible fan meant for main ventilation of large coal and ore mines that require up to 650 of air supply at pressure up to 335 MPa. Air stream reversal in the installation is executed by change of electric drive motor rotational direction with a simultaneous change of guide vanes and straightener blades angle ( ) accordingly. Reversal is carried out without the use of inlet box and bypass channel and provides 60-70% of air supplied at fan normal operation. The fan can be used either in suction, or in blowing mine ventilation systems. In other branches of industry the fan can be used to transfer air and non-aggressive gases. Fan wheel diameter, m 4,0 Flow volume (at peak point of efficiency), Static efficiency, % 81 Power of electric motor, kw 1600 Voltage, V 6000 Rotational frequency, rpm Reversal of air stream in the installation is carried out via change of electric drive motor rotational direction with a simultaneous change of guide vanes and straightener blades pitch angle ( accordingly). Reversal is implemented without the use of inlet box and bypass channel and provides 60% of air supplied during fan normal operation. The fan can be used either in suction, or in blowing mine ventilation systems. In other branches of industry the fan can be used to transfer air and nonaggressive gases. Fan wheel diameter, m 5,0 Flow volume (at peak point of efficiency), Static efficiency, % 80,6 Power of electric motor, kw 2500 Voltage, V 6000 Rotational frequency, rpm in total pressure curves Static pressure, dapa Limits at fan reversal and system resistance margin R=1.2 in relation to steady operation limit rotational frequency 375 rpm head-capacity characteristic at normal operation at reverse operation with 6 second stage impeller blades removed сurves of mine equivalent orifices Static pressure, dapa Limits at resistance margin 1.2K, steady operation limit at parallel operation and reversal head-capacity characteristic at normal operation at reverse operation rotational frequency 300 rpm 1. Weight of rotor rotating parts is 7000 kg 2. Inertia moment of one rotor is kg*m 2 3. *Dimensions for reference 4. **Weight is indicated without regard to electric motor weight 1. Weight of rotor rotating parts is kg 2. Inertia moment of one rotor is kg*m 2 3. *Dimensions for reference 4. **Weight is indicated without regard to electric motor weight 6 7

5 Fans for main ventilation of mines, shafts and production facilities of industrial enterprises ВЦ-25Б (VTs-25B) Fans for main ventilation of mines, shafts and production facilities of industrial enterprises Reversible fan system ВЦ-25Б (VTs-25B) Centrifugal fan designed for main ventilation of coal and ore mines. The fan is meant for operation in a special room exteriorly to the mine. It is used not only for single installation, but also for installation that consists of operating and reserve fans, and for parallel running of two and more fans as well. Standard model of ВЦ-25Б (VTs-25B) fan is manufactured of right and left rotation with 180 angle of scroll case turn (angle can be changed upon the request of the customer). The fan is produced on separate frames for running gear and electric motor. Running gear is carried by bearing units SKF with grease lubrication. For the sake of fine adjustment the fan is equipped with axial guide vanes. The fan is installed on foundation with the help of anchor bolts. Fan wheel diameter, m 2,53 Flow volume (at peak point of efficiency), Static efficiency, % 86 Power of electric motor, kw 400 Voltage, V 6000 Rotational frequency, rpm rotational frequency 750 rpm Static pressure, dapa 1. Maximum rotational frequency is 750 rpm 2. Inertia moment of one rotor is 1475 kg*m 2 3. Left rotation fan is a mirror reflection of right rotation 4. ** Weight is indicated without regard to electric motor weigh 8 9

6 Fans for main ventilation of mines, shafts and production facilities of industrial enterprises ВЦД-47Б (VTsD-47B) Centrifugal double-side suction fan designed for main ventilation of deep and difficult-to-ventilate coal and ore mines of enterprises belonging to metallurgical, chemical and other branches of industry. Air flow rate of the fan is up to 700, with ventilation network resistance up to 900 dapa. The fan is equipped with a variable-frequency drive, which ensures high economical efficiency of fan functioning. The fan can be used either for suction, or for blowing ventilation. There are two configurations of the fan: with partially metal scroll case (part of the scroll case is made of concrete) designed for replacement of Sever fan installation ВЦД-47 (VTsD-47), and with a completely metal scroll case. Rotor bearing units are lubricated with liquid circulating lubricant supplied from oil station which is a part of a delivery package. Adjustment is carried out via smooth change of electric motor rotational frequency. Fan wheel diameter, m 4,7 Flow volume (at peak point of efficiency), Static efficiency, % 84 Rotational frequency, rpm The fan is completed with two electric motors: asynchronous motor with 3200 kw power, 6000V direct current motor with 1600 kw power, 750V Drifting Mine Fans ВЦ-11БК (VTs-11BK) Centrifugal fan meant for trench ventilation of mines and ore workings. The fan ВЦ-11БК (VTs-11BK) can also be used for main ventilation of shallow mines and ore workings that have bypass channels, in calorifers, during mine shaft sinking, in heating and ventilating systems, for cooling of electrical machinery and for other industrial purposes. Standard model of ВЦ-11БК (VTs-11BK) is manufactured of right and left rotation with 180 angle of scroll case turn (angle can be changed upon the request of the customer). The fan is mounted on a base frame; running gear is carried by bearing units SKF with grease lubrication. For the sake of fine adjustment the fan is equipped with axial guide vanes. The fan is installed on foundation with the help of anchor bolts. Fan wheel diameter, m 1,08 Flow volume (at peak point of efficiency), 14,7 Pressure (at peak point of 325 Total efficiency, % 87 Power of electric motor, kw 55 Rotational frequency, rpm in static pressure curves in total pressure curves rotational frequency 1485 rpm Flexible curves of aerodynamic characteristics at rotational frequency rpm 1. Weight of rotor rotating parts is kg 2. Inertia moment of one rotor is kg*m 2 3. *Dimensions for reference 4. **Weight is indicated without regard to electric 1. Weight of rotor rotating parts is 500 kg 2. Maximum rotational frequency is 1500 rpm 3. Inertia moment of one rotor is 35 kg*m 2 6. ** Weight is indicated without regard to electric 7. Installation of the fan on vibration dampers is possible. Flexible curves of aerodynamic characteristics at rotational frequency rpm 10 11

7 Drifting Mine Fans ВЦ-15БК (VTs-15BK) Centrifugal fan designed for the use at coal and ore mines for ventilation during mine shaft sinking, and also for auxiliary (main) ventilation. Fan can be operated both in suction and blowing modes in systems of chemical, metallurgical and other branches of industry. Drifting Mine Fans ВЦП-16БКМ (VTsP-16BKM) Centrifugal drifting fan designed for ventilation of mine shafts with 8 m diameter and up to 1400 m depth which are put down with the use of drilling and blasting operations and are ventilated by blowing. Upon a separate request the fan ВЦ-15БК (VTs-15BK) can be completed with a reverser for main operation in a suction mode, or with a reverser for main operation in a blowing mode. Standard model of ВЦ-15БК (VTs-15BK) is manufactured of right and left rotation with 180 angle of scroll case turn (angle can be changed upon the request of the customer). The fan is mounted on a base frame; running gear is carried by bearing units SKF with grease lubrication. For the sake of fine adjustment the fan is equipped with axial guide vanes Fan wheel diameter, m 1,5 Flow volume (at peak point of efficiency), 34,5 630 Static efficiency, % 84 Power of electric motor, kw 280 Rotational frequency, rpm The fan is installed on mine surface. The fan ВЦП- 16БКМ (VTsP-16BKM) can also serve the purpose of shaft siding ventilation. Standard model of ВЦП-16БКМ (VTsP-16BKM) is manufactured of right and left rotation with 180 angle of scroll case turn (angle can be changed upon the request of the customer). The fan is mounted on a base frame; running gear is carried by bearing units SKF with grease lubrication. For the sake of fine adjustment the fan is equipped with axial guide vanes. The fan is installed on foundation with the help of anchor bolts. Fan wheel diameter, m 1,51 Flow volume (at peak point of efficiency), 27 Pressure (at peak point of 700 Total efficiency, % 84 Power of electric motor, kw 315 Rotational frequency, rpm The fan is installed on foundation with the help of anchor bolts. in total pressure curves in static pressure curves rotational frequency 1485 rpm Flow volume, thous. rotational frequency 1485 rpm Flow volume, thous. 1. Weight of rotor rotating parts is 800 kg 2. Maximum rotational frequency is 1500 rpm 3. Inertia moment of one rotor is 115 kg*m 2 6. ** Weight is indicated without regard to electric 7. Installation of the fan on vibration dampers is possible. 1. Weight of rotor rotating parts is 900 kg 2. Maximum rotational frequency is 1500 rpm 3. Left rotation fan is a mirror reflection of right rotation 4.*Dimensions for reference 5. ** Weight is indicated without regard to electric 12 13

8 Drifting Mine Fans ВШЦ-16БК (VShTs-16BК) Centrifugal drifting fan meant for trench ventilation of mines and ore workings. Gas Suction Fans УВЦГ-7Б (UVTsG-7B) Centrifugal fan designed to be used inside a mine and on its surface, as well as for auxiliary ventilation. The fan ВШЦ-16БК (VShTs-16BК) can also be used for main ventilation of mines (ore workings) in installations with bypass channels, it can operate in suction or blowing mode during shaft sinking. Besides, this fan is useful for cooling of electrical machinery and for other industrial purposes. Standard model of ВШЦ-16БК (VShTs-16BК) is manufactured of right and left rotation with 180 angle of scroll case turn (angle can be changed upon the request of the customer). The fan is mounted on a base frame; running gear is carried by bearing units SKF with grease lubrication. For the sake of fine adjustment the fan is equipped with axial guide vanes. in static pressure curves in total pressure curves Fan wheel diameter, m 1,61 Flow volume (at peak point of efficiency), 32,5 Pressure (at peak point of 300 Total efficiency, % 87 Power of electric motor, kw 132 Rotational frequency, rpm 990 electric motor), kg 4600 The fan is installed on foundation with the help of anchor bolts. Inside a mine the fan can be used: To reduce gas content in mine working area and to eliminate methane accumulation in interconnected areas of stopes and airways in coal mines that are dust- and gas-hazardous. Reduction of gas content and elimination of methane accumulation is carried out via suction of methane-air mixtures with methane content up to 3.5% from worked-out areas and their withdrawal through rigid conduits with mm diameter. As an auxiliary ventilation fan while working mine shafts. At mine surface the fan can be used as a part of gas suction plants in order to remove methane-air mixtures with methane concentration from 0 to 100% from mining extracted areas. The fan is produced on a base frame and has a doubleseat running gear carried by bearing units SKF with grease lubrication. For the sake of fine adjustment the fan is equipped with gate guide vanes. Standard model of УВЦГ-7Б (UVTsG-7B) is manufactured of right and left rotation with 180 angle of scroll case turn and 0 angle of inlet box turn (angles can be changed upon the request of the customer). Fan wheel diameter, m 0,83 Flow volume (at peak point of efficiency), 7 Pressure (at peak point of 920 Static efficiency, % 74 Power of electric motor, kw 132 Rotational frequency, rpm 3000 electric motor), kg 1450 in total pressure curves The fan is installed on foundation with the help of anchor bolts. Spark-proof materials are used in areas of possible friction of rotating parts. rotational frequency 990 rpm 1. Weight of rotor rotating parts is 850 kg 2. Maximum rotational frequency 1000 rpm 3. Inertia moment of one rotor is 180 kg*m 2 6. ** Weight is indicated without regard to electric motor weight. rotational frequency 2985 rpm 1. Weight of rotor rotating parts is 270 kg 2. Maximum rotational frequency is 3000 rpm 3. Inertia moment of one rotor is 15 kg*m 2 6. ** Weight is indicated without regard to electric 14 15

9 Gas Suction Fans УВЦГ-9Б (UVTsG-9B) Centrifugal gas suction fan designed for removal of methane-air mixtures with methane concentration from 0 to 100% from mining extracted areas through ventilation shafts and boreholes. The fan is installed at the surface of the mine as a part of gas-suction plant. Engine security level is РВ-4В (RV-4V). Climatic modification of the fan is УХЛ1 (UHL1). Standard model of УВЦГ-9Б (UVTsG-9B) is manufactured of right and left rotation with 180 angle of scroll case turn and 0 angle of inlet box turn (angles can be changed upon the request of the customer). The fan is produced on a base frame and has a double-seat running gear carried by bearing units SKF with grease lubrication. For the sake of fine adjustment the fan is equipped with gate guide vanes. in total pressure curves Fan wheel diameter, m 1,1 Flow volume (at peak point of efficiency), 16 Pressure (at peak point of 1700 Static efficiency, % 74 Power of electric motor, kw 400 Rotational frequency, rpm The fan is installed on foundation with the help of anchor bolts. Spark-proof materials are used in areas of possible friction of rotating parts.. Gas Suction Fans УВЦГ-9МБ (UVTsG-9MB) Centrifugal gas suction fan designed for removal of methane-air mixtures with methane concentration from 0 to 100% from mining extracted areas through ventilation shafts and boreholes. In comparison with the fan УВЦГ-9Б (UVTsG-9B) this fan ensures lower depression at a higher static efficiency of 81% and low power consumption. The fan is installed at the surface of the mine as a part of gas-suction plant. Engine security level is РВ-4В (RV-4V). Climatic modification of the fan is УХЛ1 (UHL1). Standard model of УВЦГ-9МБ (UVTsG-9MB) is manufactured of right and left rotation with 180 angle of scroll case turn and 0 angle of inlet box turn (angles can be changed upon the request of the customer). The fan is produced on a base frame and has a double-seat running gear carried by bearing units SKF with grease lubrication. For the sake of fine adjustment the fan is equipped with gate guide vanes. in total pressure curves The fan is installed on foundation with the help of anchor bolts. Spark-proof materials are used in areas of possible friction of rotating parts.. Fan wheel diameter, m 1,0 Flow volume (at peak point of efficiency), 16 Pressure (at peak point of efficiency), 1170 dapa Static efficiency, % 81 Power of electric motor, kw 315 Rotational frequency, rpm Па rotational frequency 2985 rpm rotational frequency 2985 rpm 1. Weight of rotor rotating parts is 320 kg 2. Maximum rotational frequency is 3000 rpm 3. Inertia moment of one rotor is 30 kg*m 2 6. ** Weight is indicated without regard to electric 7. Installation of the fan on vibration dampers is possible. 1. Weight of rotor rotating parts is 380 kg 2. Maximum rotational frequency is 3000 rpm 3. Inertia moment of one rotor is 30 kg*m 2 6. ** Weight is indicated without regard to electric 7. Installation of the fan on vibration dampers is possible

10 Gas Suction Fans УВЦГ-15БК (UVTsG-15BK) The fan is meant for removal of methane-air mixture from mine working areas (methane concentration is from 0 to 100%). The fan can be used in ambient conditions at movable mixture from 228 to 323 K, dust content up to 150 mg/m 3, density up to 1.2 kg/m 3, relative humidity up to 98% (at the of 298K), and up to 1000 m above sea level. The fan is mounted on the surface of the mine Standard model of УВЦГ-9МБ (UVTsG-9MB) is manufactured of right and left rotation with 180 angle of scroll case turn (angle can be changed upon the request of the customer). The fan is produced on a base frame and has a double-seat running gear carried by bearing units SKF with grease lubrication. For the sake of fine adjustment the fan is equipped with gate guide vanes. It is possible to supply the fan with the inlet box whether separately standing, or mounted on a base frame. The fan is installed on foundation with the help of anchor bolts. Spark-proof materials are used in areas of possible friction of rotating parts.. in total pressure curves Fan wheel diameter, m 1,65 Flow volume (at peak point of efficiency), 28 Pressure (at peak point of efficiency), 1030 dapa Static efficiency, % 73 Power of electric motor, kw 500 Voltage, V 6000 Rotational frequency, rpm rotational frequency 1485 rpm Name of the company which filled Data Sheet in: Mailing address of the company Fax Tel. Name of the company that intends to operate the industrial fan Data Sheet on a new industrial fan to be manufactured by OAO Sibenergomash Questions Answers 1 Type of industrial fan Remark: underline as appropriate 2 Climatic modification GOST Angle of turn 3 Remark: angle is measured in horizontal surface in the direction of impeller rotation, if viewed from the drive side Quantity of industrial fans: Direction of impeller rotation right-side or left-side. 4 Remark: Right-side rotation of the impeller is rotation clockwise, left-side rotation counterclockwise, if viewed from the drive side 5 Purpose of the fan (FD fan, ID fan) and name of the unit it is intended to be used for 6 Cost-effectiveness requirements desired maximum efficiency, % Characteristics of movable medium at normal conditions ( 7 О С and barometric pressure 1,013 GPa (760 mm Hg.)) 7.1 Density, kg/nm3 7.2 Concentration of solid impurities of abrasive ash, dust, etc, g/nm 3 8 Design parameters 8.1 Temperature of movable medium, О С 8.2 Excessive potential pressure (+) or vacuum (-) at fan inlet, Pa (kgf/m 2 ) 8.3 Barometric pressure of ambient air at the site of industrial fan installation, GPa (mm Hg). 8.4 Capacity with clauses 8.1, 8.2 taken into account, m 3 /h Total pressure with clauses 7.1., 8.1., 8.2. taken into account (given capacity is one specified in 8.5 clause 8.4.), Pa (kgf/m 2 ) 8.6 Tendency of impurities in movable gas to deposit on impeller blades 8.7 Percentage of aggressive components in movable gas and recommended grade of material 8.8 Maximum of movable medium, О С 8.9 Rotation frequency of impeller (desired), rpm 8.10 Necessity for capacity regulation 9 Drive motor requirements 9.1 Type (cage asynchronous, phase-wound rotor induction motor, synchronous) 9.2 Climatic modification GOST Protection level according to GOST 17494, or fully enclosed or open motor, etc. 9.4 Supply-line voltage, V 9.5 Current frequency, Hz 9.6 Additional requirements (operation mode GOST 183, number of startups, etc 10 Approximate delivery term of the fan, year 1. axial 2. centrifugal of single-side suction 3. centrifugal of double-side suction Data sheet was filled (year, month, date) 18 1.Static load on foundation under the fan with the elecric motor is 83,5 kn 2. Weight of rotor rotating parts is 650 kg 3. Inertia moment of one rotor is 155 kg*m 2 4. *Dimensions for reference 5. Weight of the electric motor 3700 kg 6. Left rotation fan is a mirror reflection of right rotation fan relative to vertical axis 7. ** Weight is indicated without regard to electric (position) (signature). (last name, patronymic, name)

11 Kalinin ave, 26, Barnaul, Altaysky kray , Russia +7 (3852) (3852) (3852) (fax) Industrial Fans Division Division Director Tyurin Nikita Alexandrovich +7 (3852) Industrial Fans Sales Department Head of Sales Department Shatilov Danil Aleksandrovich +7 (3852) Deputy Director of Mine Fans Sales Orlenko Konstantin Ivanovich +7 (3852) (ext. 4480)

DAE Systems. Fan Selection Guide. Section 1: Terminology

DAE Systems. Fan Selection Guide. Section 1: Terminology DAE Systems Fan Selection Guide Section 1: Terminology CFM : Cubic Feet per Minute Technical Terms This refers to the amount of air a fan is able to move. Pressure Inches of water is a common method of

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

Selecting the Correct Fan

Selecting the Correct Fan Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications

More information

Horizontal Split Case Pumps Type U

Horizontal Split Case Pumps Type U Horizontal Split Case Pumps Type U 7.1 7.2 Stage U Type Pumps Features: Axially Split Case Design Range from 20M 3 /Hr to 600M 3 /Hr Two Stage Pump Single Suction Twin Volute Casing Design Closed type

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR COMBUSTIBLE GASES MCF 00 centrifugal fan for biogas, natural gas or combustible gases, in conformity to the

More information

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals. SECTION 23 21 23 - HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate

More information

Introduction to Fans. The Basics of Fan Principles and Terminology

Introduction to Fans. The Basics of Fan Principles and Terminology Introduction to Fans The Basics of Fan Principles and Terminology Airflow Principles A fan is a rotating device that creates pressure differential that results in air movement Pressure rise in a fan Downstream

More information

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components: Pumps DOE-HDBK-1018/1-93 CENTRIFUGAL PUMPS CENTRIFUGAL PUMPS Centrifugal pumps are the most common type of pumps found in DOE facilities. Centrifugal pumps enjoy widespread application partly due to their

More information

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESB Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Axial flow fan AXICO ANTI-STALL

Axial flow fan AXICO ANTI-STALL Product data sheet: AXICO ANTI-STALL Axial flow fan AXICO ANTI-STALL Model FPAC and FPMC axial flow fans with controllable pitch blades. Air flow range: 3-110 m³/s (10.000 400.000 m³/h). Pressure rise:

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

CNS CENTRIFUGAL MULTISTAGE WATER DESCALING PUMPS BB4 TYPE API 610 ENGINEERING FLOW SOLUTIONS

CNS CENTRIFUGAL MULTISTAGE WATER DESCALING PUMPS BB4 TYPE API 610 ENGINEERING FLOW SOLUTIONS CNS CENTRIFUGAL MULTISTAGE WATER DESCALING PUMPS BB4 TYPE API 610 ENGINEERING FLOW SOLUTIONS CNS Pumps For Water Descaling Description The CNS series pumps are centrifugal, multistage, horizontal, with

More information

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork. SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving

More information

SUMY Catalogue. Product Line. Centrifugal Pumps СУМЫ SUMY ENGINEERING WORKS Ltd PUMPING EQUIPMENT DESIGN, MANUFACTURE AND SALE

SUMY Catalogue. Product Line. Centrifugal Pumps СУМЫ SUMY ENGINEERING WORKS Ltd PUMPING EQUIPMENT DESIGN, MANUFACTURE AND SALE SUMY 2009 Catalogue Product Line Centrifugal Pumps СУМЫ 2008 SUMY ENGINEERING WORKS Ltd PUMPING EQUIPMENT DESIGN, MANUFACTURE AND SALE SUMY ENGINEERING WORKS Ltd is a Company specialized in the design

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

CAP SERIES SEWAGE AND WASTE WATER PUMPS

CAP SERIES SEWAGE AND WASTE WATER PUMPS Part 8 CAP SERIES SEWAGE AND WASTE WATER PUMPS TECHNICAL SPECIFICATIONS : Turbosan CAP series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

Ducted Propeller. Airflow Volume

Ducted Propeller. Airflow Volume Total Pressure Radial-Blade Centrifugal Tubeaxial Backward-inclined Airfoil Centrifugal Forward-curved Centrifugal Ducted Propeller Airflow Volume Figure 2: Forward-Curved Centrifugal Fan

More information

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESF Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Fans: Features and Analysis

Fans: Features and Analysis Technical Development Program COMMERCIAL HVAC EQUIPMENT Fans: Features and Analysis PRESENTED BY: Michael Ho Version 1.2 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section

More information

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS

CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS TABLE OF CONTENTS Introduction...3 Selection & Application.....4 Selection Examples......5-6 Ratings......7-8 Correction Factors......9-10

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Centrifugal Fans, Non-Overloading, Backward Inclined

Centrifugal Fans, Non-Overloading, Backward Inclined BACKWARD INCLINED CENTRIFUGAL FANS Centrifugal Fans, Non-Overloading, Backward Inclined MVA, MVZ, MVX & MVW Series with laminar blades MAVA, MAVZ & MAVX Series with aerofoil blades Features The combination

More information

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING USER S MANUAL VCU/ Series CENTRIFUGAL FAN IN SCROLL CASING 2 CONTENTS Introduction Use Delivery set Designation key Technical data Safety requirements Design and operating logic Mounting and set-up Connection

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

Copy Right By: Thomas T.S. Wan

Copy Right By: Thomas T.S. Wan Chapter 23 Motor and Starter Copy Right By: Thomas T.S. Wan 温到祥著 Sept. 3, 2008 All rights reserved Electric Motors All the motors are to be designed and constructed in accordance with NEMA code. Electric

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide 1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide Installation Location! The pump should be located as close as possible to the liquid source so that the suction line can be as short and direct

More information

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL CENTRIFUGAL FAN IN SCROLL CASING Helix S-Vent EN OPERATION MANUAL Helix / S-Vent www.blaubergventilatoren.de CONTENTS CONTENTS 3 Introduction 3 Use 3 Delivery set 4 Technical data 10 Safety requirements

More information

ECO-ANT21 Corporation

ECO-ANT21 Corporation ANT Turbo blower - Summary Turbo Blower is a device generating compressed air using an applied air bearing, impeller, high speed motor, inverter and controller connected to a robust centrifugal turbine

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer: Installation & Operating Manual RSV Chimney Fan USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter

More information

Instructions for the BASIC BCRW Fan, Sizes General

Instructions for the BASIC BCRW Fan, Sizes General Instructions for the BASIC BCRW Fan, Sizes 004 027 1. General The BCRW is a direct-driven fan of axi-centrifugal design. This fan offers excellent power efficiency, low, uniform air flow, low sound generation

More information

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems. 15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html

More information

IEC- Direct-driven radial fans with IEC-Standardmotor

IEC- Direct-driven radial fans with IEC-Standardmotor EHND / ERND / ERNE / Contents. / Page 1. / Safety... 2 2. / Description... 4 3. / Condition of use... 4 4., / Storage, Transport... 5 5. / installation... 6 6. / operation... 8 7. / maintenance... 9 8.

More information

Variable speed hydraulic coupling and drive unit of hydraulic coupling

Variable speed hydraulic coupling and drive unit of hydraulic coupling Variable speed hydraulic coupling and drive unit of hydraulic coupling I. Model designation YO / / / Modificait on code Output speed of drive unit (r/min) Input speed of coupling or drive unit (r/min)

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Axial Flow Fans Good Design Guide

Axial Flow Fans Good Design Guide Axial Flow Fans Good Design Guide 45 Heales Road, Lara VIC, Australia 3212 Phone +61 3 5275 6644 Facsimile +61 3 5275 3333 INTRODUCTION: Air Radiators have been manufacturing heat transfer and air movement

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater SUPPLY UNITS Series Series LCD control panel SAS908 control panel Supply units with the air capacity up to 3500 m 3 /h in the compact sound- and heat-insulated casing with electric heater Supply units

More information

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO ASME/ANSI B73.1 Chemical Process Pump Tel: 866-777-66 Horizontal Split Case For more than 6 years the name Ruhrpumpen TM has been synonymous worldwide

More information

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve seal Bearing Enclosed Gland packing Sleeve bearing (Lubricant oil) Water cooling jacket Bearing, Stuffing box (81-120 C) seal: External flushing PUMP Suction side JIS10K normal type Discharge side JIS10K

More information

Fan Selection. and Energy Savings

Fan Selection. and Energy Savings Fan Selection and Energy Savings Reducing power consumption by minimizing system pressure loss and choosing the right equipment HBy BRIAN MLEZIVA Greenheck Fan Corp. Schofield, Wis. Power Consumption HVAC

More information

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

Lenntech. Tel Fax bar. Multistage Pumps.

Lenntech. Tel Fax bar. Multistage Pumps. Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 100 bar Multistage Pumps Vogel Series MPE Technical Data Performance Range: m Capacity up to 300m 3 /h (1320USgpm)

More information

ENERVEX RSV CHIMNEY FAN

ENERVEX RSV CHIMNEY FAN ENERVEX RSV 200-450 CHIMNEY FAN 3000775 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

FREQUENTLY ASKED QUESTIONS. COMMISSION REGULATION (EU) No 327/2011. of 30 March 2011

FREQUENTLY ASKED QUESTIONS. COMMISSION REGULATION (EU) No 327/2011. of 30 March 2011 FREQUENTLY ASKED QUESTIONS TO COMMISSION REGULATION (EU) No 327/2011 of 30 March 2011 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements

More information

Operating instructions Plug Fans Direct driven with asynchronous or PM synchronous motor (Translation of the Original)

Operating instructions Plug Fans Direct driven with asynchronous or PM synchronous motor (Translation of the Original) Operating instructions Plug Fans Direct driven with asynchronous or PM synchronous motor (Translation of the Original) EN BA-CFD_RLM 9.4 09/2014 RLM E3 RLM 53 RLM 55 RLM E6 RLM G6 RLM 56 Contents 1. Important

More information

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER Cinzia Buratti, Elisa Moretti and Michele Urbani Department of Industrial Engineering, University of Perugia, via G. Duranti 67, 06125 Perugia,

More information

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories... . - B 97 Product Detail... B98 Benefits... B100 Construction Details... B102 Custom Features and Options... B103 Accessories... B Engineering Data... B107 Structural Support... B111 Engineering Specifications...

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR General DICKOW-pumps of series HZ/HZA are single- or multistage centrifugal pumps with shaft sealing. Application HZ/HZA-pumps are applied

More information

Installation of Two Main Fans at P.T. Freeport Indonesia's Underground Facilities

Installation of Two Main Fans at P.T. Freeport Indonesia's Underground Facilities 463 Installation of Two Main Fans at P.T. Freeport Indonesia's Underground Facilities F. Calizaya and A. Mulyadi P.T. Freeport, l'ldonesia Irian-Jaya, Indonesia. ABSTRACT This study summarizes the technical

More information

PRODUCT REVIEW. Low Pressure Blowers. Medium Pressure Blowers. High Pressure Blowers. Side Channel Blowers. Conveying Blowers FD RD F

PRODUCT REVIEW. Low Pressure Blowers. Medium Pressure Blowers. High Pressure Blowers. Side Channel Blowers. Conveying Blowers FD RD F PRODUCT REVIEW Low Pressure Medium Pressure ND RD Side Channel High Pressure SD HRD Conveying FD RD F TECHNICAL INFORMATION Conversion table Units of measurement from unit of measurement with conversion

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS Installation & Operating Manual 3001806 03.02 USA CAN BESF Box Ventilator READ AND SAVE THESE INSTRUCTIONS 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731

More information

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original) Montageanleitung (Original) (Translation of the original) DE MA_ 1.0 06/2014 Taperlock Clamping-bush system _0 _1 Fixed hub Inlet nozzle with IMV 1. Revision index Revision Date MA_ 1.0 06/2014 2. Safety

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNIT HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX351 July 2001 AXICO ANTI-STALL Controllable Pitch-In-Motion and Adjustable Pitch-At-Rest Vaneaxial Fans Types FPAC, FPMC, FPDA A complete product bulletin including performance

More information

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Inline mixed-flow fans with the air capacity up to 450 m 3 /h FANS FOR ROUND DUCTS Series VENTS ТТ PRO Series VENTS ТТ perform required servicing. All the models may be equipped with a regulated timer with turn-off delay adjustable from 2 to 30 min. TT PRO design

More information

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans 1 - mj,, Donkin Fans Majax-2 Aerofoil Axial Flow Fans - IW '~AJAX-2 GENERAL SPF ~IFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request),

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO ASME/ANSI B73.1 Chemical Process Pump Horizontal Split Case For more than 6 years the name Ruhrpumpen TM has been synonymous worldwide with innovation

More information

Specially Designed Waste Water & Sewage Pumps

Specially Designed Waste Water & Sewage Pumps Specially Designed Waste Water & Sewage Pumps Technical specifications Ebitt SC series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and other

More information

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2 3002239 RSIF 2014-04-04 Installation and operation manual RSIF power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation

More information

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges TM High Performance in Wastewater Pumping HOMA submersible water and wastewater pumps operate worldwide in numerous domestic, municipal

More information

FAN ENGINEERING. Surge, Stall and Instabilities in Fans

FAN ENGINEERING. Surge, Stall and Instabilities in Fans FAN ENGINEERING Industrial Fans & Services Information and Recommendations for the Engineer Surge, Stall and Instabilities in Fans Introduction Users of fan systems would like to experience a steady, continuous

More information

Air flow management tutorial session. ACC Users Group 8 th Annual Conference Dallas, 4 October 2016 Sander Venema Howden Netherlands

Air flow management tutorial session. ACC Users Group 8 th Annual Conference Dallas, 4 October 2016 Sander Venema Howden Netherlands tutorial session ACC Users Group 8 th Annual Conference Dallas, 4 October 2016 Sander Venema Howden Netherlands Howden Group 2016 Introduction Basic definitions Basics of fan performance Basics of fan

More information

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS NEW! TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS Turbo Blowers Blower housings from cast aluminum, closed impellers from sheet aluminum, maintenance-free squirrel cage rotor motors of our own manufacture

More information

Evaluation Report 509

Evaluation Report 509 Printed: June 1987 Tested at: Lethbridge ISSN 0383-3445 Group 5i Evaluation Report 509 Prairie Pride TR-36 Series Ventilation Fans A Co-operative Program Between ALBERTA FARM MACHINERY RESEARCH CENTRE

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html

More information

Multistage Centrifugal Blowers/ Exhausters CAST SERIES

Multistage Centrifugal Blowers/ Exhausters CAST SERIES Multistage Centrifugal Blowers/ Exhausters CAST SERIES ONE PLUS ONE EQUALS NUMBER ONE IN MULTISTAGE CENTRIFUGAL BLOWERS For more than 100 years, two names were synonymous with multistage centrifugal blowers:

More information

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER Submersible borehole pump People at KSB we make your world flow round! UPZ PUMP POWER FOR TOP PERFORMANCE UNDER THE TOUGHEST CONDITIONS UPZ is top choice wherever submersible borehole pumps have to satisfy

More information

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan FAN TYPES In order to cover a wide range of applications, fans are manufactured in a variety of type. They can be classified under three general types : (a) Centrifugal, (b) Axial and (c) Mixed flow. Table

More information

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html

More information

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html

More information

CR A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR1-16 A-FJ-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651222 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651222/cr-1-16-a-fj-a-e-hqqe.html

More information

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR32-4 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9612213 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612213/cr-32-4-a-f-a-e-hqqe.html

More information

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps Series 0 & FILE NO: d. DATE: June, 00 SUPERSEDES: d. DATE: July, 00 dualarm Vertical In-Line Pumps dualarm Smart pumps for the commercial HVAC market Vertical In-Line pump, the best design for HVAC systems,

More information

HMS CIRIS BOREHOLE SUBMERSIBLE PUMPS

HMS CIRIS BOREHOLE SUBMERSIBLE PUMPS ENGINEERING FLOW SOLUTIONS HMS CIRIS BOREHOLE SUBMERSIBLE PUMPS About HMS GROUP HMS Group being the leading Russian pump manufacturer and EPC solutions provider offers state-of-the-art pumps and systems,

More information

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html

More information

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans A look at two accepted technologies.. System Characteristics In general, the pressure developed by a fan is a function

More information

Fuji Electronic VFC 084P-5T

Fuji Electronic VFC 084P-5T Fuji Electronic VFC 084P-5T Fuji s complete line of ring compressors is designed to meet the most critical application requirements. Each features an impeller, mounting base and housing manufactured of

More information

VETO CLEANER 500 FLUE GAS CLEANER

VETO CLEANER 500 FLUE GAS CLEANER As of serial number 3100 0001 VETO CLEANER 500 FLUE GAS CLEANER USER MANUAL SPARE PARTS LIST Manufacturer: ALA TALKKARI Veljekset Ala-Talkkari Oy FI-62130 HELLANMAA TEL. +358 6 433 6333 FAX +358 6 437

More information

IPVB EC inline power venter

IPVB EC inline power venter Installation and operation manual IPVB 300-500 EC inline power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation Chapter

More information

Scientific-Research Institute of Metallurgical Heat Engineering OJSC VNIIMT

Scientific-Research Institute of Metallurgical Heat Engineering OJSC VNIIMT High temperature industrial fans (heat-proof fans) designed by OJSC "VNIIMT" Development, design and manufacture of heat transfer convection thermal furnaces on the basis of the high temperature industrial

More information