Sporlan Valve Division Parker Hannifan/CIC Group
|
|
- Ruth Malone
- 5 years ago
- Views:
Transcription
1
2 Sporlan Valve Division Parker Hannifan/CIC Group Matt McGrath, SW Regional Sales Manager Bob Dolan, Sales Engineer - Atlanta
3 Why Discuss TEVs Today? Expansion Valves are you re Future Important Component to Reaching 13 SEER Provide Better Performance over Entire Operating Range Protect Compressor from Flood back Better Performance with low/high charge
4 How TEVs Improve SEER! TEVs close when compressor is off!!!!! Isolates most of the Charge in Outdoor Unit Evaporator starts cooling air faster on start up However, TEVs Improve Efficiency
5 TEVs vs Cap Tube/Restrictors Fixed Restrictor Evaporator Superheat Flood TEV Provides Improved Efficiency TEV Capacity Rating Point TEV Protects Compressor Outdoor Temperature ºF
6 FIXED RESTRICTOR EEV ELECTRONIC EXPANSION VALVE TEV CAPILLARY TUBE EVAPORATOR CONDENSER AEV AUTOMATIC EXPANSION VALVE COMPRESSOR Copyright 2002 By Sporlan Valve Company, Washington, MO TEV-03 ( /04)
7 The Function of a Thermostatic Expansion Valve To keep coil as completely refrigerated as possible under all load conditions Copyright 2002 By Sporlan Valve Company, Washington, MO TEV-04 ( /04)
8 Temperature Control Suction Pressure Control Humidity Control Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-05 ( /04)
9 Basis for Nominal TEV Capacities REFRIGERANT 134a A 410A Pressure drop across port - psi Evaporator temperature, F Liquid temperature entering TEV, F Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-17 ( /04)
10 The Valve Responds to Input from the Bulb Feed Me More! EVAPORATOR Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-18 ( /04)
11 Principal Parts of Any TEV Diaphragm Seat Capillary Tube Pushrods Bulb Pin Spring Guide Spring Adjusting Stem Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-24 ( /04)
12 Three Factors Effecting Normal TEV Capacity PIN ANGLE (some are flat) STROKE PORT SIZE Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-26 ( /04)
13 TEV Controlled Superheat EVAPORATOR 50 F AIR Bulb Evaporator Pressure COMPRESSOR Spring Pressure Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-27 ( /04)
14 Three Fundamental Pressures Bulb Pressure = Evaporator Pressure + Spring Pressure Bulb Pressure Opening Force Closing Force 2 Evaporator Pressure 3 Spring Pressure Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-74 ( /04)
15 Valve with INTERNAL Equalizer Valve with EXTERNAL Equalizer Internal Equalizer Push Rods Evaporator Outlet Pressure Close Tolerance Fit Push Rods External Equalizer Fitting Valve Outlet Pressure Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-40 ( /04)
16 30 F Sat. 55 psig TEV Pressure Balance p 6 psi 49 psig 20 F Sat. 43 psig EVAPORATOR SPRING 12 psig REFRIGERANT EVAPORATING TEMPERATURE F COMPRESSOR PRESSURE DROP - psi 12, 134a A, 502, (Ammonia) Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-41 ( /04)
17 Gas Charged and Type CP Air Conditioning Charged Element Liquid Completely Vaporized No Liquid In Bulb (Gas) Pressure (psig) (Liquid Present) Temperature Pressure Bulb Evaporator Pressure Temperature ( F) Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-53 ( /04)
18 Type CP Air Conditioning and GA Charges FlowMaster Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-65 ( /04)
19 Types CP Air Conditioning and GA Charges on Floodback The FlowMaster element 1. Can successfully reduce or even eliminate hunting 2. Provide steady performance Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-66 ( /04)
20 Anti-Hunt Principle 1. Opens slowly - steady response 2. Closes quickly - prevents floodback Copyright 2004 By Sporlan Valve Company, Washington, MO TEV-67 ( /03)
21 2001 Sporlan/Trane TEV Field Returns Approx ppm Field Returns 24% % of items Returned 76% Non Manfacturing Causes All Manufacturing Defects
22 Break Down of Non Manufacturing Causes 40% 35% 30% 25% 20% 15% 10% 5% 0% No Failure Found Broken Cap- Tube Field Damaged Contamination
23 Breakdown of Manufacturing Defects 12% 10% 8% 6% 4% 2% 0% Charge Leak External Leak Incorrect Setting Incorrect Assembly
24 Sporlan & Trane Working Together to Reduce TEV Warranty Issues Field Training Eliminate Unnecessary Replacement Improved Cap Tube Processing In 2003 Sporlan Implemented Numerous Improvements to Prevent Tube from Breaking In 2006 TEVs will be Factory Installed Sporlan Leak Task Team Continuous Improvements to Reduce Leaks
25 Check Valve Operation Contains Internal Check Valve Provides Low P Reverse Flow for Heat Pump Systems Eliminates External Check Reduces Braze Joints Model: CBBIE
26 The liquid line joins various high side components, BUT its primary function... Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-06( )
27 supply vapor free liquid to the TEV inlet, despite pressure loss from 1 Flow friction Inlet 2 Vertical lift 3 Flow through accessories Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-07( )
28 Example: R-22 How much subcooling is needed? Vertical lift is 20 so pressure loss is about psi Pressure loss due to flow friction is about psi Pressure loss across accessories is about psi Total pressure drop psi Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-12( )
29 B A B Condensing pressure for R-22 is 220 psi and saturation temperature is F (220 psig) Because of losses, pressure at TEV inlet is 202 psi and saturation temperature is F (202 psig) C Subcooling required is A.. 6 F Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-13( )
30 TEV s primary job: supply the proper amount of refrigerant under all load conditions Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-18( )
31 Superheat 29 PRESSURE PSI 2 Actual temperature at bulb minus saturated temperature (corresponding to pressure at bulb) Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-21( )
32 R PRESSURE PSI PSI PRESSURE Actual temperature at bulb F 68.5 psig Saturated temperature corresponding to 68.5 psig F Operating superheat F Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-22( )
33 And it s easy to blame the valve Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-03( )
34 Bulb location is important Mount on a horizontal free draining section on the suction line at the evaporator outlet Important conditions are: 1 Thermal contact 2 Circumferential location Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-28( )
35 1 Thermal Contact Mount on straight, clean section parallel to suction line not on fitting not with tape Flow no! yes! Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-29( )
36 2 Circumferential Location On larger lines, position bulb at 4 o clock or 8 o clock Never mount at bottom Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-30( )
37 2 No need to disassemble, but... a b c d Direct flame away from body Avoid oversized torch tip Avoid excessive heat on diaphragm Keep flame away from bulb 3 Use dry nitrogen for a reducing atmosphere Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-44( )
38 Evacuate non-condensibles and water from the system using a well maintained vacuum pump Why not use the system s compressor? 1 Not designed as a vacuum pump 2 Not properly lubricated 3 Compressor oil may be contaminated 4 Compressor motor may overheat Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-47( )
39 4 Basic Scenarios 1 Feeds not enough 2 Feeds too much 3 Feeds not enough, then too much 4 Floodback only during start up Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-54( )
40 PRESSURE PRESSURE PSI PSI LOW HIGH Causes 1 Moisture, dirt, wax 2 Undersized valve 3 High superheat adjustment 4 Gas charge condensation 5 Dead thermostatic element 6 Wrong thermostatic charge 7 Evaporator pressure drop no external equalizer 8 External equalizer location Symptom See-Saw 9 Restricted or capped external equalizer 10 Low refrigerant charge 11 Liquid line vapor vertical lift, high friction loss, long or small line, plugged drier or strainer 12 Low pressure drop across valve same as no. 11 above, undersized distributor nozzle or circuits, low condensing pressure Feeds not enough Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-55( )
41 PRESSURE PSI HIGH LOW Causes Symptom See-Saw 1 Oversized valve 2 TEV seat leak 3 Low superheat adjustment 4 Bulb installation: poor thermal contact, warm location 5 Wrong thermostatic charge 6 Bad Compressor low capacity 7 Moisture, dirt, wax 8 Incorrectly located external equalizer Feeds too much Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-56( )
42 PRESSURE PRESSURE PSI PSI Causes LOW 1 Low load not enough air, dirty air filters, air too cold, coil icing 2 Poor air distribution 3 Poor refrigerant distribution Symptom See-Saw LOW 4 Improper compressor evaporator balance 5 Evaporator oil logged 6 Flow from one TEV affecting another s bulb Hunts feeds not enough, then too much Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-57( )
43 Hunting and Cycling System Single Compressor and Evaporator Multiple Evaporators with one compressor or compressors with capacity reduction Symptoms Variation in both suction pressure and superheat Superheat variation but only slight suction pressure change Feeds not enough, then too much Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-58( )
44 Causes 1 Oversized valve 2 TEV seat leak Flood-back only during start-up 7 Compressor in cold location 8 Suction line in cold location Floodback 3 Low superheat adjustment 4 Bulb installation: poor thermal contact, warm location 5 Compressor discharge valve leak 6 Solenoid valve seat leak 9 Evaporator draining freely to compressor 10 Interrupted pump down 11 Restricted or plugged external equalizer 12 Wrong thermostatic charge Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-59( )
45 Valve performance can never be restored or improved by physical force Disassembly might uncover the problem Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-72( )
46 Eliminate the problem Copyright 2002 by Sporlan Valve Company, Washington, Missouri SS-73( )
47 Additional Training Available Training will Reduce Warranty Costs Call on Sporlan to Assist with Deal & Contractor Training in Your Area
48 Thank You & Questions
XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1
Page 1 WHY should I install the XSTREAM Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,
More informationMYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1
Page 1 WHY should I install the MYSTICOOL Max Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,
More informationBulletin , March Electric Hot Gas Bypass Valves
Bulletin 100-60, March 2018 Electric Hot Gas Bypass Valves PAGE 2 / Bulletin 100-60 10 FEATURES AND BENEFITS SDR-4 Direct temperature control Tight shutoff when closed Can be interfaced with direct digital
More informationTable of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)
Table of Contents Refrigeration Cycle Service Procedures Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8) Solving Problems Identifying Low System Charge (9-11) Identifying High
More informationQuickTips. Do you have questions? We have answers.
Do you have questions? We have answers. WARNING USER RESPONSIBILITY Failure or improper selection or improper use of the products described herein or related items can cause death, personal injury and
More informationEverything You. NEED to KNOW. TXV does this by keeping the coil supplied
Everything You NEED to KNOW About TXVs } With the higher SEER air conditioners, technicians need to reacquaint themselves with thermostatic expansion valves B Y A L M A I E R Before the 13 SEER minimum
More informationInstallation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant
EarthLinked TXV Kit Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant CONTENTS PAGE Pre-Installation 3 Air Handler Conversion 4 System
More informationPowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois
Althouse Turnquist Bracciano PowerPoint Presentation by: Associated Technical Authors Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Chapter 5 Explain the purpose and operation of
More informationTHERMOSTATIC EXPANSION VALVES Part 1
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 THERMOSTATIC EXPANSION VALVES Part 1 Revised by Loren Shuck, CMS INTRODUCTION The thermostatic expansion valve (frequently
More informationOtherwise, you can continue reading the file on the following pages.
If you d like to be able to print this file out to study off-line or use on the job, a printable version is available for an administrative fee of $3.97 USD. To download the unlocked file, click here.
More informationInstructors: Contact information. Don Reynolds Doug McGee Factory Tech Support
Contact information Instructors: Don Reynolds 616-560-9903 Doug McGee 517-294-3932 Factory Tech Support 888-593-9988 Product Improvements for 2017 Todays Objectives Job Site Information Sheets Low Ambient
More informationInstallation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT
EarthLinked TXV Kit Installation Manual for Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT CONTENTS PAGE Pre-Installation 3 Hydronic Water Module Conversion
More informationPROJ. NO SECTION REFRIGERANT PIPING
SECTION 23 23 00 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMASS. MARITIME ACADEMY
MASS. MARITIME ACADEMY REFRIGERATION LAB OUTLINE Rev.3 Fall 2015 Table of Content Page Lab #1: Introduction to refrigeration system components, tools and procedures 1 Lab #2: Familiarization, operation,
More informationA Treatise on Liquid Subcooling
A Treatise on Liquid Subcooling While the subject of this article is Liquid Refrigerant Subcooling, its affect on the operation of the thermostatic expansion valve (TEV), and ultimately on system performance
More informationSystem Considerations for Refrigerant Blends with Temperature Glide
System Considerations for Refrigerant Blends with Temperature Glide Theory and Practical Retrofit Guidance Table of Contents 1 2 3 4 5 Blend and Glide Basics... 3 1.1 Superheat and Subcooling of Refrigerant
More informationInstallation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant
EarthLinked TXV Kit Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant CONTENTS PAGE Pre-Installation 3 Cased Coil Conversion 4 System Start-Up 17 TXV CCS-410-KIT
More informationChapter-8 Capacity Control of Refrigeration Systems
Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control
More informationSECTION (15530) - REFRIGERANT PIPING
SECTION 23 23 00 (15530) - REFRIGERANT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. 3. Joining Materials. 4. Specialties. B. Related Sections: 1. Section 07 92 00 (07920)
More informationDESIGN STANDARDS SECTION 15600
PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating
More informationNovember 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES
November 2006 / BULLETIN -60 ELECTRIC DISCHARGE BYPASS VALVES PAGE 2 / Bulletin -60 10 FEATURES AND BENEFITS Direct temperature control Tight shutoff when closed Can be interfaced with direct digital controls
More informationEclipse Technical Training CME686 CME810 CP686 CP886 CP1086
Eclipse Technical Training CME686 CME810 CP686 CP886 CP1086 In This Presentation What Eclipse is Components and their functions Installation Operation Maintenance Service Diagnosis The Eclipse System The
More informationRESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES
SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant
More informationR Series Cooling Modules
R Series Cooling Modules Models RCM/RPM 50 RCM 70 RM 100 RM 140 Manufactured By Energy Saving Products Ltd. Standard ESP 105.03 Refrigerant Modules (RCM/RM) Fig. 02 - Mounting brackets The cooling coil
More informationCondensing Unit Installation and Operating Instructions
Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.
More informationINSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL
INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL MODELS: WA242H WA36H NOTE: Electrical data presented in this manualsupersedes any other data for the above listed models. Bard Manufacturing
More informationfor Valve Types P-H-M-V-W-D-A
August 2004 / Bulletin 60-15 for Types P-H-M-V-W-D-A FOR USE ON REFRIGERATION and/or AIR CONDITIONING SYSTEMS ONLY Bulletin 60-15 August 2004 Supersedes Bulletin 60-15 August 1996 and all prior publications.
More informationTHERMOSTATIC EXPANSION VALVES Part 2
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 THERMOSTATIC EXPANSION VALVES Part 2 Revised by Loren Shuck, CMS INTRODUCTION The previous chapter dealt briefly with
More informationCase 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage
Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage Copy Right By: Thomas T.S. Wan ) Dec. 28, 2012 All Rights Reserved Case Background: Ammonia is one of the important elements to
More informationREFRIGERANT PIPING SYSTEM
PART 1 GENERAL 1.01 DESCRIPTION A. The requirements of this section apply to the refrigerant piping system connecting refrigeration and HVAC equipment specified in other sections of these specifications.
More informationREFRIGERANT PIPING
SECTION 232300 - REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationAPPLICATION and INSTALLATION
Page 2 / Bulletin 60-15 5 BENEFITS OF THE 1 2 3 4 5 Modulated flow The Level-Master Control provides a modulated flow and maintains practically a static liquid level in the low side. No moving parts The
More informationBASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation
INTRODUCTION In recent years air conditioning industry technology has advanced rapidly. An important byproduct of this growth has been development of the heat pump. Altogether too much mystery has surrounded
More informationJune 2001 / BULLETIN Way Valves. The right solenoid valve for any job.
June 01 / BULLETIN - 3-Way Valves The right solenoid valve for any job. Page 2 / Bulletin - Advantages Sporlan 3-Way Valves 3-Way Pilot eliminates costly high- to low-side leaks. "B" reduces total installed
More informationR Series Cooling Modules
TM Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems R Series Cooling Modules Models RCM-50 RCM-70 RM-100 Manufactured By Module-RCM/RM-Series-Installation-Manual-120113 Refrigerant
More informationThe Saturation process
SOUTH METROPOLITAN TAFE WA The Saturation process Dennis Kenworthy 8/5/2016 A student study guide to measuring and interpreting the saturation process of refrigeration and air-conditioning equipment System
More informationSECTION (15530) - REFRIGERANT PIPING
PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. SECTION 23 23 00 (15530) - REFRIGERANT PIPING 3. Joining Materials. 4. Specialties. B. Related Sections: 1.02 REFERENCES 1. Section
More informationTechnical Training Associates Presents. Commercial Refrigeration Equipment Servicing Part 1
Technical Training Associates Presents Commercial Refrigeration Equipment Servicing Part 1 By Jim Johnson A Practical Approach To The Fundamentals Of Walk-Ins, Reach-In and, Display Cases: Restaurant,
More informationFor an administrative fee of $9.97, you can get an un-locked, printable version of this book.
The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. For an administrative fee of
More informationDAVE DEMMA ACHIEVING HEAD PRESSURE CONTROL
BY DAVE DEMMA ACHIEVING HEAD PRESSURE CONTROL In the September/October 2005 issue of HPAC Magazine, the case was made for reducing head pressure to increase compressor efficiency, thereby lowering its
More informationThese valves can also be ordered as a bidirectional valve, allowing control of flow in both directions for use on heat pump applications.
Type EBS/O Type EBS and O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer.
More informationRatio Architects, Inc. Section Refrigerant Piping
SECTION 232300 - REFRIGERANT PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant pipes and fittings. 2. Refrigerant piping valves and specialties. 3. Refrigerants. 1.2 ACTION SUBMITTALS
More informationHeat Reclaim. Benefits,Methods, & Troubleshooting By Dave Demma, Manager Supermarket Sales, Sporlan Division - Parker Hannifin Corporation
Form 30-217 / January 2007 Heat Reclaim Benefits,Methods, & Troubleshooting By Dave Demma, Manager Supermarket Sales, Sporlan Division - Parker Hannifin Corporation While the vapor-compression cycle has
More informationInstruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS
English Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Instruction Manual
More informationRCM Refrigerant Module
Small Duct High Velocity Heating, Cooling and Home Comfort Systems RCM Refrigerant Module Installation Manual Manufactured By Module-RCM-Refrigerant-Module-Installation-0666 Refrigerant Modules (RCM) Fig.
More informationAPPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)
4-1280 Application Engineering Bulletin AE-1280R4 Revised April, 1995 APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) Introduction The Compliant Scroll Compressor has been
More informationG Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton
G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1
More informationAIR CONDITIONING. Carrier Corporation 2002 Cat. No
AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)
More informationHow to Diagnose a TXV Failurek
How to Diagnose a TXV Failurek There has been much written and many jokes made about the misdiagnosis of TXV (Thermostatic expansion valves) and rightly so. This article will cut straight to the point
More informationWarm Case Troubleshooting Guide 9/18/2014
Introduction Warm cases can be caused by various problems which require thorough troubleshooting. Begin the investigation with questions to store personnel asking for information such as when the last
More informationSome of these procedures need to be performed to conform to requirements of the Clean Air Act.
Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.
More informationSECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING
SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING UNIT OBJECTIVES After studying this unit, the reader should be able to Select the correct instruments for checking an air conditioning unit
More informationThermoSaver TM Hot Gas Defrost System
PRODUCT DATA, APPLICATION & INSTALLATION GUIDE Supplement to Condensing Unit Installation and Maintenance Manual Bulletin K40-THERM-PDI-15 Part # 1069130 PRODUCT SUPPORT web: k-rp.com/ts email: mdcu-lgcu@k-rp.com
More informationCalhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration
Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in
More informationThermoSaver TM Hot Gas Defrost System
PRODUCT DATA, APPLICATION & INSTALLATION GUIDE Supplement to Condensing Unit Installation and Maintenance Manual Bulletin B40-THERM-PDI-14 1069132 ThermoSaver TM Hot Gas Defrost System For use on select
More informationInstallation and Operation Manual
series Installation and Operation Manual FGCEID GLASS DOOR REACH-IN This refrigerator conforms to the Commercial Refrigerator Manufacturers Association s Health and Sanitation Standard. series Page 2 INSTALLATION
More informationDAVE DEMMA REDUCING ELECTRICAL CONSUMPTION
BY DAVE DEMMA REDUCING ELECTRICAL CONSUMPTION It is said that necessity becomes the mother of invention. As energy prices soared in the 1970s, supermarket owners sought ways to reduce their enormous utility
More informationCondensing Unit Installation and Operating Instructions
Bulletin ACU_O&I 02 August 2016 Condensing Unit Installation and Operating Instructions ACU Air Cooled Condensers Table of Contents Section 1. General Information... 2 Section 2. Refrigeration Piping...
More informationThe Essentials Of Working With R-410A
The Essentials Of Working With R-410A By Norm Christopherson Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of 410A continues
More informationINSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!
4AC 14* ASA1 SERIES R-410a CONDENSING UNITS INSTALLATION GUIDE R-410A ATTENTION, INSTALLER! After installing the system, show the user how to turn off electricity to the unit. Point out control and switch
More informationService Step by Step Trouble-Shooting Check-List
WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:
More informationProdigy Eclipse Cuber Technical Training
Prodigy Eclipse Cuber Technical Training 600 800 1000 1200 1400 1800 2000 In This Presentation What Eclipse is Components and their functions Installation Operation Maintenance Service Diagnosis The Prodigy
More informationKE2 EvaporatorEfficiency Theory of Operation
Theory T.1.1 June 011 TM thermsolutions ENTER BACK KE Therm Solutions, Advanced Energy Saving Technology for Commercial Refrigeration and AC Systems Page Table of Contents Basic Refrigeration System Evaporator
More informationAir Conditioning Clinic. Refrigerant Piping One of the Fundamental Series TRG-TRC006-EN
Air Conditioning Clinic Refrigerant Piping One of the Fundamental Series TRG-TRC006-EN NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST-CLASS MAIL PERMIT NO. 11 LA CROSSE,
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET General Piping Recommendations and Refrigerant Line Length for Split-System Air Conditioners and Heat Pumps GENERAL GUIDELINES This Split-System (Air Conditioning Condensing/Heat
More informationSERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11
SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume
More informationEarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions
EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 10 Antifreeze Protection 14 Electrical
More informationUSING THE P-T CARD AS A SERVICE TOOL
Service Application Manual SAM Chapter 620-115 Section 2 USING THE P-T CARD AS A SERVICE TOOL Reprinted with permission from Sporlan Division, Parker Hannifin Corporation INTRODUCTION Manufacturers of
More informationR-407A R-448A R-449A
GUIDELINES FOR THE UTILIZATION OF R-407A R-448A R-449A 2018 Tecumseh Products Company LLC. All rights reserved. Page 1 of 9 R-407A, R-448A, and R-449A are recognized as suitable alternative refrigerants
More informationR Series Cooling Manual
Mini Duct Heating and Air Conditioning Indoor Air Quality Systems R Series Cooling Manual Includes: RPM-E-50 Cooling Module RPM-E-0 Cooling Module RPM-E-00 Cooling Module Manufactured By Energy Saving
More informationSECTION REFRIGERANT PIPING
SECTION 23783 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationNational Maritime Center
National Maritime Center Providing Credentials to Mariners U.S.C.G. Merchant Marine Exam (Sample Examination) Page 1 of 26 Choose the best answer to the following Multiple Choice Questions. 1. If a condenser
More informationInstallation Manual BCS2000/3000
Installation Manual BCS2000/3000 Supplies Needed for Installation 1. 3/8 and 5/8 copper tubing. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120v 15A circuit for
More informationNON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL
NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL DATE OF PURCHASE: MODEL: SERIAL NO.: Record above information from nameplate. Retain this information for future reference.
More informationEXPANSION VALVES. See Red Dot Catalog Also. * 2 ton valves - all other valves are 1 1/2 ton (1) Includes M1 Adapter 71R8050 EX02280
EXPANSION VALVES See Red Dot Catalog Also PART NO. DESCRIPTION INLET OUTLET FITTING -- INTERNAL EQUALIZED 20359 INTERNAL EQUALIZED 38722 INTERNAL EQUALIZED FITTING -- EXTERNAL EQUALIZED 71R8050 EXTERNAL
More informationCAUTION. Check Equipment and Job Site. Clearance Requirements. Unpack Unit
INSTALLATION IMPORTANT: Effective January 1, 2015, all split system and packaged air conditioners must be installed pursuant to applicable regional efficiency standards issued by the Department of Energy.!
More informationMortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS
Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph
More informationSECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING
SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING UNIT OBJECTIVES After studying this unit, the reader should be able to Describe how refrigerant is charged into systems in
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH
TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More information442 Chapter 16. Figure 16-5 Gas leak detection
BRORANE BRORANEBRORANEBRORANEBRORANEBRORANEBRORANEBRORANE 442 Chapter 16 Tur n e r BRORANE FUEL EBRORANEBRORANEBRORANEBRORANEBRORANE Figure 16-5 Gas leak detection is easy. This sensitive halide detector
More informationHVAC/R Refrigerant Cycle Basics
HVAC/R Refrigerant Cycle Basics This is a basic overview of the refrigeration circuit and how it works. It isn t a COMPLETE description by any means, but it is designed to assist a new technician or HVAC/R
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.
MAKING MODERN LIVING POSSIBLE Thermostatic expansion valves, type REFRIGERATION & AIR CONDITIONING DIVISION Technical leaflet Technical leaflet Thermostatic expansion valves, type Contents Page Introduction........................................................................................3
More informationPULSE WIDTH MODULATING VALVES
PULSE WIDTH MODULATING VALVES PARKER PULSE WIDTH MODULATING VALVES MODEL HP P4144 MODELS CS & DS P4145 Features Long life (100 million cycles). Suitable for all common refrigerants except ammonia. Maximum
More informationSECTION 50 - CAB CLIMATE CONTROL
AIR CONDITIONING SYSTEM DYNAMIC DESCRIPTION The refrigerant circuit of the air conditioning system contains five major components: Compressor, Condenser, Receiver/Drier, Expansion Valve, and Evaporator.
More informationPARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer
PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer 5/16 Rev. A 57-02509 2 Contents INTRODUCTION... 4 WARNING LABELS AND SAFETY INSTRUCTIONS... 5 PS SERIES PARALLEL
More informationHEAT PUMPS. Carrier Corporation GT72-01 Cat. No
HEAT PUMPS Carrier Corporation 2003 GT72-01 Cat. No. 020-018 1. This refresher course covers topics contained in the HEAT PUMPS specialty section of the North American Technician Excellence (NATE) certification
More informationContour TM Screw Compressors
Contour TM Screw Compressors Semi-Hermetic Compact Operating Instruction SCH1 High Temp Compressors Form No. 99-77 1. Introduction This series of semi-hermetic compact screw compressors is designed for
More informationRDT Refrigeration Book
RDT Refrigeration Book Indoor / Outdoor Air-Cooled Systems Indoor Air-Cooled Systems 1. Shorter line runs. 2. Systems located off roof or dock space. 3. Weather covers are not required (saves cost). 4.
More informationSERVICE BULLETIN A
1. PLANNING INFORMATION A. Effectivity: Dassault Falcon 10 aircraft which have installed R-134a Upgrade Kit SZ59K-R134 before August 8, 2002. B. Reason: Upgrade kits before August 8, 2002 did not include
More informationTrouble Shooting Guide RAA, 1-phase (D3627)
Trouble Shooting Guide RAA, 1-phase (D3627) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose
More informationApplication and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS
Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A900-22007), 120/208/240/1/60, R404A, LT/MT APPS Introduction The superheat controller is designed
More informationPURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN
VALVES VESSELS SYSTEMS CONTROLS PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN System drawings shown in this bulletin are for illustration purposes only. Refrigeration systems
More informationTrouble Shooting Guide PAA, 1-phase (D3731)
Trouble Shooting Guide PAA, 1-phase (D3731) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose
More informationINSTALLATION & OPERATION MANUAL
series K//W Part #:31E03-027 Date: 9-00 Supersedes: INSTALLATION & OPERATION MANUAL M4N3 Multi-Deck, Narrow, Meat Merchandiser This case conforms to the Commercial Refrigerator Manufacturers Association
More informationInstallation Manual BCS 1000/1500
Installation Manual BCS 1000/1500 Supplies Needed for Installation 1. Double insulated refrigerant line set. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120V 15A
More informationSeries 1140 and 1141 Temperature Regulators
Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE
More informationHeat Exchangers DKRCC.PF.000.G1.02 / 520H6410
Contents MicroChannel Exchanger Construction... 2 MicroChannel Exchanger Cleaning Procedure... 4 Micro Plate Exchanger MPHE Instructions... 5 MicroChannel Exchanger MCHE Instructions... 7 Troubleshooting
More informationMECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers
MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING Sample Questions and Answers CHAPTER 5 EVAPORATORS 1. What is Evaporator? Classify the various types of evaporator. Evaporator
More informationDOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)
DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee 37091 Phone (931) 359-6211 1-800-251-8990 www.doleref.com PHO WATER DEFROST OPERATION & MAINTENANCE MANUAL June 2002 PHO WATER DEFROST Table
More informationA/C-HEATER SYSTEM - MANUAL
A/C-HEATER SYSTEM - MANUAL 1986 Isuzu Trooper II 1986 A/C-HEATER SYSTEM Isuzu A/C-Heater Systems - Manual P UP, Trooper II * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system,
More information