Copyright All rights reserved. wwwdomoteck.com & all related companies The materials in this page, may not be

Size: px
Start display at page:

Download "Copyright All rights reserved. wwwdomoteck.com & all related companies The materials in this page, may not be"

Transcription

1

2 Heating Systems The modern heating system was developed during the past century when oil was the main source of energy. Oil based hot water generators were installed in homes all around Europe, hot water was produced and stored in liter tanks at C and was not only used for sanitation but also for heating. The average heat loss of a house/apartment was around 200W/m 2. Rooms were equipped with radiators in which hot water was circulated, this form of heat radiating at a very low efficiency accumulated at ceiling level, as a result dry air and a very uncomfortable feeling. However, this heating system became the standard and state of the art, plumbers were educated to install the system and mechanical engineers calculated the heat loss of an average house/apartment, calculating each room separately to size the radiator at a set temperature. Industry developed different components such as: valves, radiators, tanks, oil and gas heaters etc, wholesalers were the source for the plumbers, however the plumber was in charge of the system and he had the responsibility to ensure that the system functioned properly. Of course new ideas developed in order to provide a higher comfort as standards of living grew, therefore next to the radiator a floor heating system was developed based on both electric and water. The water based system reached a bigger market share mainly due to the availability of hot water, although in those days floor heating systems had their drawbacks. This was due to the need of relatively high floor temperatures to answer the 200W/m 2 heat loss, both systems were impossible to regulate. However temperatures were low and stable for a period. Installation became more complicated as other crafts where needed to complete the installations. To improve performance insulation was required, this and the concrete poured over the pipes became the responsibility of the installers. Over the years the demand for floor heating systems increased especially in high level homes designed by architects, floor heating gave freer wall space. The HVAC engineer as well as the plumber needed to be better educated to ensure a well functioning system. During the end of the 80 s and beginning of the 90 s the need to save energy became a very important issue, the answer was better insulation and as such decreased heat loss. Targets were set to reach heat loss levels of less than 75Wm 2. Floor heating systems became the preferred solution to heat the home, water temperatures needed to be relatively low. Apart from oil, gas and hot water generators other systems where designed. The Heat Pump became the most advanced system the industry was able to develop. The drawback of the Air Water Heat Pump is the phenomenon that when the outside temperature drops the efficiency (C.O.P) drops too. At the same time the Heat Pump will generate hot water at a lower temperature. Solutions were found to back up the Heat Pump by an electrical unit to ensure hot water at 40 C needed to heat the home. The Heat Pump system gained position and became state of the art Today due to climate changes new technologies are required; people need both heating and cooling. We are entering a new area which means: HOME ACCLIMATIZATION Home Acclimatization is needed more and more in town apartments and small offices as windows can not be opened due to pollution and noise. Improved insulation needs less energy to heat and cool an apartment. A well sized Air Water Heat-Pump will answer the need in the future for a comfortable indoor climate. Modern Air Water Heat-Pumps are quiet and maintenance free. A modern ACU (Air Circulation Unit ) will gently and quietly circulate the air at a speed set by the home owner. Climateck ACU includes a filter which will maintain a clean and dust free environment Climateck ACU can be installed on walls at heights that will still give architects the advantages as in floor heating systems. 2

3 Climateck = Home Acclimatization Climateck a member of the Decora Group headed by Dan Klein, represents innovative products. Domoteck also a member of the Decora Group is the pioneer of floor warming systems developed during the 90's, and is a main OEM supplier of electrical floor warming products to numerous well known companies world-wide Decora Group Having over 20 years of production and marketing experience are well known for: Reliability Quality Safety Energy saving ClimaTeck s Kit Systems are the future in Home Acclimatization. Acclimatization symbolizes : Improved home climate In very cold Areas: Climateck Acclimatization Water Based Floor Heating systems can be installed in any room larger than 7m 2 Electrical heating mats or cables can be installed in rooms smaller than 7m 2 such as bathrooms, etc. In Areas with mild winters and mild to warm summers: ClimaTeck's Heat Pump connected to Air Circulated Units (ACU) will answer Heating & Cooling needs. Electrical mats/cables can be installed in small areas such as bathrooms and wash rooms. For the ultimate level of comfort you can also integrate ClimaTeck's comfort products such as : towel warmers, fog free mirror, etc. 3

4 Controlled water temperature, heated or cooled by the Energy Unit & Heat Pump-B is constantly circulated in the copper pipes of the ACU (Air Circulation Unit). The temperature then disperses to the fins and the heated/cooled air is then circulated into the room by the fan, at a pre set temperature or in 3-5 different speeds which are set manually. Water Temperature in heating mode Max 45 C to prevent air from drying Home Acclimatization The Fan transports heated air into the room as desired. 5 ACU s 9000 Btu SDU A Energy Unit 2/3x3kWh The air in the room is constantly circulated by the fan. ClimaTeck Heat Pump-B 12k or 36k Btu Water temperature in cooling mode will not fall below 2 C as set in the CU-HA-535 thermostat, however the water temperature can be set between 2 C 7 C. As such the temperature in the ACU (Air Circulation Unit) will maintain a comfortable air flow into the room The Fan transports cooled air into the room as desired. 5 ACU s 9000 Btu SDU A Energy Unit 2/3x3kWh The air in the room is constantly circulated by the fan. Climateck Heat Pump-B 12k or 36k Btu 4

5 Heat Distribution In high temperature heating systems (left), the heat rises, dissipating as it rebounds back to floor level. In low temperature heating systems (right), the heat becomes gradually cooler as it rises, maintaining the heat at levels that warm the feet, body and head. High Temperature Heating Systems represent the technology of the past Low Temperature Heating Systems represent the technology of the future 5

6 APPLICATIONS & OPTIONS HEATING Heat Pump-B Btu is joined through a gas pipe to an Interface Grey Btu + an Expansion Tank which is connected to 3x PDU-HP 6LOOPS 6kW Heating Element (TOTAL 18 LOOPS FOR UNDERFLOOR HEATING) for installation in a 200m 2 zone. Connection pipes not included - they must be of copper or PEX reinforced with an aluminium layer. 6x DP 16/2 6x DP 16/2 6x DP 16/2 6

7 APPLICATIONS & OPTIONS Forced Air HEATING & COOLING Heat Pump-B Btu is joined through a gas pipe to an Interface Grey Btu which is connected to 3x SDU Z-P. Each SDU Z is connected to 4 Air Circulating Units 12 in total of your choice. (up to max Btu see page 20) Connection pipes not included they must be of copper or PEX reinforced with an aluminium layer. ACU Ceiling Cassette Hydronic Fan Coil ACU - Wall ACU - Floor OS 7

8 Basic hydronic accessories Systems SDU-A 3 Loops SDU-A 4 Loops SDU-A 5 Loops Description Plated Metal Sheet: 3 Loops - 250mmx450mm 4 Loops - 300mmx450mm 5 Loops - 350mmx450mm Header Cabinet For built-in installation made from Galvanized Sheet Metal Front powdered white RAL 9010 Available in 3 sizes - Dimensions on request SDU - AS-P 2 Loops Includes: Pressure Gauge Tap for water flow Controlled By-Pass Adjustable Flow Meter for each loop 3/4' Clamping Ring for each loop PDU-A 2 Loops Includes: Made of 1 stainless steel ADU-3-4 Loops Includes: Manifold 3/4' made of brass - Circulation Pump 25W-230V Pressure Gauge - Mini-Tank made of 1 stainless steel Electrical Unit 15.6 Amp 3X1200W Control Box includes Terminals Coupling System especially for 16/2mm Dowlex -Pipe Energy Unit 3OP 5kW-h Energy Unit IV 5kW-h Connected to Heat Pump-B forming the basic parts of an acclimatization system Interface-Grey DC Inverter Air to Water Heat Pump Heat Pump Heat Pump - B 12,000 Btu Heat Pump - B 18,000 Btu Heat Pump - B Btu 8

9 Dowlex-Pipe Basic hydronic accessories Description Dowlex-Pipe 8/1.2 mat 0.5 x 2.0 = 1.0 Dowlex-Pipe 8/1.2 mat 0.5 x 4.0 = 2.0 Dowlex-Pipe 8/1.2 mat 0.5 x 6.0 = 3.0 Dowlex-Pipe 8/1.2 mat 0.5 x 8.0 = 4.0 Dowlex-Pipe 8/1.2 Made of Dowlex with an oxygen barrier layer In rolls of 200m Dowlex-Pipe 16/2 - Made of Dowlex with an oxygen barrier layer In rolls of 90m & 200m Dowlex-Pipe 17/2 - Made of Dowlex with an oxygen barrier layer In rolls of 200m Dowlex-Pipe 20/2 - Made of Dowlex with an oxygen barrier layer In rolls of 200m Installation Description Black Angles - To help prevent the Dowlex-Pipe from breaking when connecting to the SDU-A. Hooks - To Fix the 16mm - 20mm Dowlex-Pipe to the Domo-ISO RJ system panel. Fixing Strips- For anchoring the 8mm/200m Dowlex- Pipe Domo-ISO RJ System Panel Insulation Panel with foil backing & printed grid - 50mm distances. Security Border Strip- 160 x 8mm with PE Strap to connect to the system panel. Polyethylene Foil- To lay over the insulation for separation from the concrete. Thickness -0.2 Width m Folded to 1m rolls of 35m. Tools Description Pipe Cutter - For cutting the Dowlex-Pipe to the required length of the loops. Stapling Machine - To insert the hooks with the Dowlex -Pipe to the Domo-ISO RJ System Panel. 9

10 Components Basic hydronic accessories Description Adapter For correlation with other systems Filling &Draining Valve To be installed at the end of the water inlet & water outlet bar Blind Cap 3/4 - To close a not needed outgoing & in going circuit. Connector Nipple 3/4 Eurocone Nickel Plated to be installed at the Blank Port to add additional loops Regulating Valve To be installed in the water outlet bar Thermostatic Valve To be installed in the water inlet bar Ball Valves - R1, Brass Nickel Plated Flow Meter - Balancing Valve Direct regulation, reading & shut-off of flows in systems Pipe Fitter - Consisting of cap nut 3/4 Clamping Ring & Pipe Spout. To fix the Round Pipe to the manifold by 3/4 Euro cone. 16mm (16 x 2.5mm round pipe) (17mm (17 x 2.5mm round pipe) 20mm (20 x 2.5mm round pipe) WBS-FRC Unit - Electrostatical Valve. Thermostat to open and close valve Sensor + Tube Black Angle 90 x 2 per loop CU HA 535-S Thermostat for Home Acclimatization Systems Actuator 230V type Alpha To open and close the water flow each loop Cable length 1m Terminal Strip 230V - To connect the Thermostat to the Actuators Ventilation 1/2 To be installed at the Blank Port as needed Expansion Tank 2 Liter 10

11 SDU A Heat-Pump Inverter Interface Grey Heat Pump-B Endless possibilities with Climateck Energy Unit-30P Energy Unit-IV SDU B SDU B-V SDU AS-PC Climateck has developed a diverse range of water based systems for your choice. The guiding principle of Climateck systems is Low-Temperature Heating. This is enabled by heating a large area of the floor surface, rather than concentrating the heating source in radiators or hot air blowers. Low temperature heating results in reduced energy consumption and costs, as well as providing a particularly pleasant form of warmth. Climateck's water based systems offer flexible configurations, adaptable for heating different sized areas, from individual rooms up to the entire house. You can choose between a stand-alone system with its own heating element, or a system that connects to an external hot water source based on electricity, gas, oil, heat pump, or solar energy. ClimaTeck's systems can be used to supplement any conventional central heating system and provide extra warmth in critical areas at certain times of the day. SDU AS-PC-V SDU Z P SDU Z P-V Why Climateck Water Based Systems Climateck has the answer to your needs: New construction Renovation Extensions Home Improvements Easy to combine with standard radiators Easy to connect to high temperature water sources ADU 3-4 Climateck has many options: Stand alone systems Systems that connect to hot water sources Air Circulation Unit ADU 1-2 F-RC PDU Basic PDU HP PDU ET AC-Floor OS ACU Ceiling 11

12 Climateck KIT Example: for an area of 100m 2 2x SDU-Z-PV Energy Unit 3OP Heat Pump-B CU HA-535-S CU 517 SR 90m Dowlex-Pipe 16/2 Hooks: 180 units per loop 90 0 Black Angle x 2 per loop 4 Screws and plastic plugs are attached to the kit. CU 517-SR CU HA 535-S D-P 16/2 12

13 ADU connected to Dowlex Pipe 13

14 Dowlex Pipe Layout 14

15 Sizing Climateck Heat Pump Basics The optimal operating situation for the Heat-Pump will be at an outside temperature of 7 C and water temperature of 35 C. In this situation the Heat Pump will provide a 3.3 C.O.P (1 Kwh input will result in 3.3 Kwh output). When temperatures drop below 0 C the C.O.P drops to a point where the cost of electricity will be the same if the Heat-Pump or an electrical resistance element is used. When sizing the Heat-Pump it s essential to calculate no more than 70% of the operation time. The heat loss of a building is calculated to 65W/m 2 in all areas. Meaning that if the lowest outside temperature in certain areas is -15 C the insulation is increased compared to an area in which the temperature drops below +2 C. However in both cases the heat loss will be at the lowest temperature 65W/m 2. This means that in areas where the lowest outside temperature is 15 C a smaller size Heat-Pump in combination with an electrical unit will be needed compared to and area where the lowest outside temperature does not drop below +2 C. The rational is that in the -15 C area the Heat-Pump will be in operation only when the outside temperature will be above 0 C. However at this outside temperature the heat loss of the building will only be about 30 to 40W/m 2 and as such the required Kwh to keep the apartment warm will drop by half. When the lowest outside temperature is only +2 C then the Heat-Pump can answer the Kwh needed. 15

16 Basic information Lowest outside temperature. Outside temp. -15 C Heat loss 65W/m 2 Kwh needed to keep house/apartment warm 7.87 C.O.P of HP will drop to 1 Electrical Unit will supply the heat needed 7.9 Kwh Size your heat Pump room temp 22.0 out side Temp c to - 2c Delta T % 1.8 COP not to be less than % Kwh Needed 7.87 Btu Amps Elec Unit Kwh 7.90 Basic information Mid season temperature Outside temp. +2 C Heat loss 40W/m 2 Kwh needed to keep house/apartment warm 4.84 C.O.P of HP will be 1.8 will fully answer heating demand Size your heat Pump room temp 22.0 out side Temp 2.0 3c to - 2c Delta T % 2.2 COP not to be less than % Kwh Needed 4.84 Btu Amps Elec Unit Kwh Basic information Lowest outside temperature. Outside temp. -+2 C Heat loss 65W/m 2 Kwh needed to keep house/apartment warm 7.87 C.O.P of HP will drop to 1.87 actual saving electricity Size your heat Pump room temp 22.0 out side Temp 2.0 3c to - 2c Delta T % 2.2 COP not to be less than % Kwh Needed 7.87 Btu Amps Elec Unit Kwh Basic information Mid season temperature Outside temp.-+7 C Kwh needed to keep house/apartment arm 4.84 C.O.P of HP will be 3.3 heat pump will operate only 41% of the time instead of 70% HP will fully answer heating demand actual saving electricity Size your heat Pump room temp 22.0 out side Temp 7.0 3c to - 2c Delta T % 2. 4 COP not to be less than % Kwh Needed 4.84 Btu Amps

17 Table 1 Information input The Project: 100m 2 3 bedroom apartment Table 2 Results Results Based on information given the results aren't optimal and won't supply the required indoor temperatures when outdoor temperatures are at their lowest. Water temp. is too low Solution Water temp. should be raised to 40 C and the difference between inlet and outlet water temp. to be raised to 7 C. Doing so will influence the volume of water needed to transfer the heat. Floor and room temp. will be raised. See changes on following page. 17

18 Table 1 Information input The Project: 100m 2 3 bedroom apartment Table 2 Results Changes made Temperature raised to 40 C and inlet, outlet to 7 C Result Less volume needed decreased to 1123 L/h Room temperature Now answers the home owners needs 18

19 Heat Pump-Inverter DESCRIPTION & FEATURES: Connects to Energy Unit with PEX pipes Increases the efficiency of the system Refrigerant R410A Quiet and maintenance free TECHNICAL DATA: Characteristics Operation voltage Input Power (W) Cooling Heating C.O.P (W/W) Refrigerant Noise Level (dba) Weight (kg) Indoor/Outdoor Dimensions (mm) Indoor Unit Outdoor Unit Air Flow Rate (m³/h) Piping Connection Nominal Capacity BTU/h Cooling Heating Btu V/50Hz 1Ph R410A 35/54 20/33 600x400x x255x G3/

20 Interface Grey DESCRIPTION & FEATURES: Connects to Climateck s Heat Pump-B Increases the efficiency of the system Refrigerant R410A Quiet and maintenance free TECHNICAL DATA: Characteristics Power Supply Btu V / 50-60Hz Nominal Cooling Capacity Nominal Heating Capacity Btu-9.37kW Btu 10.54kW Type Heat Exchanger Water Piping Connection Water Pressure Drop Max. Water Flow Dimensions (LxDxH) Net Weight High Efficiency Tub in Shell G3/4 8 kpa 2.5m 2 /h 500x520x kg Refrigerant piping Connection Water Pump Type IP44 TF 110 C, Class H R410A 3/8 ; 1/2 GPD 25-8S 135;190;225W 20

21 Heat Pump-B DESCRIPTION & FEATURES: Connects to Energy Unit with copper pipes Increases the efficiency of the system Controlled by CU 535 (supplied with EU) Quiet and maintenance free TECHNICAL DATA: Characteristics Btu Btu Btu Operation voltage 230V AC 50Hz 230V AC 50Hz 230V AC 50Hz Power of electrical unit 230V/ 50HZ/ 1PH/ 1300W 230V/ 50HZ/ 1PH/ /1800W 230V/ 50HZ/ 1PH/ 2200W C.O.P (Bar) Refrigerant R410A R410A R410A Noise Level (dba) Weight (kg) Dimensions (mm) 870x320x x350x x430x790 Air Flow Rate (m³/h) Gas Valve (inch) 1/2;1/4 5/8;3/8 3/4;3/8 21

22 Energy Unit 3OP The Energy Unit 3OP connected to the Heat Pump-B is a basic part of the acclimatization system and is ideal for water based floor heating and air cooling. DESCRIPTION & FEATURES: The Energy Unit 3OP is connected to Heat Pump-B together they are the basic parts of an acclimatization system Ideal for water based under floor heating and also for air cooling & heating. Operated by CU HA-535-S, which controls the water temperature (30 C-55 C) in the Mini Tank and the Heat Pump-B condenser temperature. TECHNICAL DATA: Characteristics Operation voltage Power of electrical unit Whirl pump power Whirl pump ingress protection Operation pressure (Bar) Max. water temp. Dimensions (mm) Weight (kg) Capacity of Mini-Tank (L/h) Heat Exchanger Energy Unit 3OP 230V AC 50Hz 230V - 3x3000W - 3X14A 65W IP C (Max) 750x650x R410A PDU ingress protection IPX3 Double Protection against OVER HEATING 1) GFCI (RCD) 2) Thermal Switch (60 C) 22

23 Energy Unit IV The Energy Unit IV connected to the Heat Pump-B is a basic part of the acclimatization system and is ideal for water based floor heating and air cooling. DESCRIPTION & FEATURES: The Energy Unit IV is connected to Heat Pump-B together they are basic parts of an acclimatization system Ideal for water based under floor heating and also for air cooling & heating. Operated by CU HA-535-S, which controls the water temperature (30 C-55 C) in the Mini Tank and the Heat Pump-B condenser temperature. TECHNICAL DATA: Characteristics Operation voltage Power of electrical unit Whirl pump power Whirl pump ingress protection Operation pressure Max. water temp. Dimensions Weight Capacity of Mini-Tank Heat Exchanger PDU ingress protection Energy Unit IV 230V AC 50Hz 230V - 2x3000W Vario 9-63W IP bars 55 0 C (Max) 750x650x kg 1.5L R410A IPX3 Double Protection against OVER HEATING 1. GFCI (RCD) 2. Thermal Switch (60C) 23

24 SDU A-KIT Standard Distribution Unit assembled with: A Blank Port (capped) Made of 1 stainless steel Suitable for 16/2mm Dowlex-Pipe 4 x 8mm holes for mounting SDU-A on the wall Mounted on a Plated Metal Sheet (1.5mm thick) SDU A - 3 Loops (available in 3, 4, 5 loops) The Kit Includes: SDU A Manifold Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer Length per loop 90m (Example: 2 loops = 2 rolls of 90m or alternatively 1 roll of 200m (20m bonus) Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm Hooks: 180 units per loop 90 0 Black Angle x 2 per loop 4 Screws and Plastic Plugs - attached to the kit An Adapter enabling coupling of systems Adapter SDU A-3 Loops coupled with SDU A-4 Loops Dowlex-Pipe 16/2mm Length 200m Thermostat optional Measurements: SDU A - 3 loops 450 X 250 X 10 SDU A - 4 loops 450 X 300 X 10 SDU A - 5 loops 450 X 350 X 10 Measurements: SDU A-KIT with 90m Dowlex- Pipe (on pallet) 3 loops 800 X 800 X 81 4 loops 800 X 800 X 99 5 loops 800 X 800 X

25 SDU B-KIT Standard Distribution Unit assembled with: For each loop: Adjustable Flow Meter - Mechanical Valve - 3/4 Clamping Ring Made of 1 stainless steel Suitable for 16/2mm Dowlex-Pipe Mounted on a Plated Metal Sheet 1.5mm thick Covered by ABS casing 4 x 8mm holes for mounting the SDU B on the wall The Kit Includes: SDU B Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer Length per loop 90m Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm Hooks: 180 units per loop 90 0 Black Angle x 2 per loop 4 Screws and Plastic Plugs are attached to the kit Measurements SDU B - 2 loops 600X650X160 SDU B - 3 loops 600X650X160 SDU B - 4 loops 600X650X160 SDU B - 5 loops 750X650X160 SDU B - 6 loops 750X650X160 SDU B - 7 loops 750X650X160 SDU B - 8 loops 900X650X160 SDU B - 9 loops 900X650X160 SDU B - 10 loops 900X650X160 12kg 12.5kg 13kg 14kg 14.5kg 15kg 15.5kg 16kg 16.5kg Thermostat optional Measurements SDU B-KITS 2 loops 800X800X760 40kg 3 loops 800X800X940 51kg 4 loops 800X800X kg 5 loops 800X800X kg 6 loops 1300X800X790 88kg 7 loops 1300X1000X790 99kg 8 loops 1300X800X kg 9 loops 1300X1000X kg 10 loops 1300X800X kg 25

26 SDU B-V KIT Standard Distribution Unit assembled with: For each loop: Adjustable Flow Meter - Mechanical Valve - 3/4 Clamping Ring An Electrical Terminal Box to wire the Electrostatical Valve to the Room Thermostat Air Release Valve Controlled By-Pass Made of 1 stainless steel Actuator to open and close water flow in each loop (Actuator is controlled by thermostat placed in each room) Suitable for 16/2mm Dowlex-Pipe Mounted on a Plated Metal Sheet 1.5mm thick Covered by ABS casing 4 x 8mm holes for mounting the SDU B-V on the wall The Kit Includes: SDU B-V Manifold Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer Length per loop 90m Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm Hooks: 180 units per loop 90 0 Black Angle x 2 per loop 4 Screws and plastic plugs are attached to the kit. Thermostat optional Measurements SDU B-V - 2 loops 600x650x kg SDU B-V - 3 loops 600x650x kg SDU B-V - 4 loops 600x650x kg SDU B-V - 5 loops 750x650x kg SDU B-V - 6 loops 750x650x kg SDU B-V - 7 loops 750x650x kg SDU B-V - 8 loops 900x650x kg SDU B-V - 9 loops 900x650x kg SDU B-V- 10 loops 900x650x kg Measurements SDU B-V KITS 2 loops 800x800x kg 3 loops 800x800x kg 4 loops 800x800x kg 5 loops 800x800x kg 6 loops 1300x800x kg 7 loops 1300x1000x kg 8 loops 1300x800x kg 9 loops 1300x1000x kg 10 loops 1300x800x kg 26

27 SDU AS-PC-KIT Standard Distribution Unit assembled with: For each loop: Adjustable Flow Meter - Mechanical Valve - 3/4 Clamping Ring 3 Step Circulating Pump /W - 230V L/H Pressure Gauge Control Box includes Terminals and Pump Activator Timer (when not in a heating period) Flow Valve & Tap to allow hot water to the manifold and Dowlex-Pipe Air Release Valve Controlled By-Pass Made of 1 stainless steel Suitable for 16/2mm Dowlex-Pipe Mounted on a Plated Metal Sheet 1.5mm thick Covered by ABS casing 4 x 8mm holes for mounting the SDU AS-PC on the wall The Kit Includes: SDU AS-PC Manifold Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer Length per loop 90m Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm CU 518-MW to control the water temp. in the manifold Hooks: 180 units per loop 90 0 Black Angle x 2 per loop 4 Screws and Plastic Plugs are attached to the kit Measurements SDU AS-PC - 2 loops 600X650X160-14kg SDU AS-PC - 3 loops 600X650X kg SDU AS-PC - 4 loops 600X650X160-15kg SDU AS-PC - 5 loops 750X650X160-17kg SDU AS-PC - 6 loops 750X650X kg SDU AS-PC - 7 loops 750X650X160-18kg SDU AS-PC - 8 loops 900X650X160-19kg SDU AS-PC - 9 loops 900X650X kg SDU AS-PC - 10 loops 900X650X160-20kg Thermostat optional Measurements SDU AS-PC-KITS 2 loops 800X800X760-43kg 3 loops 800X800X940-54kg 4 loops 800X800X kg 5 loops 800X800X kg 6 loops 1300X800X790-92kg 7 loops 1300X1000X kg 8 loops 1300X800X kg 9 loops 1300X1000X kg 10 loops 1300X800X kg 27

28 SDU AS-PC-V-KIT Standard Distribution Unit assembled with: For each loop: Adjustable Flow Meter - Mechanical Valve 230V - 3/4 Clamping Ring 3 Step Circulating Pump /W - 230V L/H Pressure Gauge Control Box includes terminals and Pump Activator Timer (when not in a heating period) Electrical Terminal Box to wire the Electrostatical Valve to the Room Thermostat Flow Valve & Tap to allow hot water to the manifold and Dowlex- Pipe Air Release Valve Controlled By-Pass Made of 1 stainless steel Actuator to open and close water flow in each loop (Actuator is controlled by thermostat placed in each room) Suitable for 16/2mm Dowlex-Pipe Mounted on a Plated Metal Sheet 1.5mm thick Covered by ABS casing The Kit Includes: SDU AS-PC-V Manifold Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer Length per loop 90m Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm CU 518-MW to control the water temp. in the manifold Hooks: 180 units per loop 90 0 Black Angle x 2 per loop 4 Screws and plastic plugs are attached to the kit. Measurements SDU AS-PC-V - 2 loops 600X650X160-15kg SDU AS-PC-V - 3 loops 600X650X160-16kg SDU AS-PC-V - 4 loops 600X650X160-17kg SDU AS-PC-V - 5 loops 750X650X160-18kg SDU AS-PC-V - 6 loops 750X650X160-19kg SDU AS-PC-V - 7 loops 750X650X160-20kg SDU AS-PC-V - 8 loops 900X650X160-21kg SDU AS-PC-V - 9 loops 900X650X160-22kg SDU AS-PC-V - 10 loops 900X650X160-23kg Thermostat optional Measurements SDU AS-PC-V-KITS 2 loops 800X800X760-45kg 3 loops 800X800X940-56kg 4 loops 800X800X kg 5 loops 800X800X kg 6 loops 1300X800X790-94kg 7 loops 1300X1000X kg 8 loops 1300X800X kg 9 loops 1300X1000X kg 10 loops 1300X800X kg 28

29 ADU X90/16 Loop KIT ADU 3-4/16 Active Distribution Unit assembled with: Circulation Pump 25W-230V Pressure Gauge Mini-Tank made of 1 stainless steel Manifold 3/4' made of brass Expansion Tank Electrical Unit 15.6 Amp 3X1200W Control Box includes Terminals Flow Valve to allow hot water to the manifold and Dowlex-Pipe Coupling System especially for 16/2mm Dowlex-Pipe Mounted on a 1.5mm Metal Sheet Covered by ABS casing The Kit includes: ADU 3-4 Manifold 4 x 16/2mm Dowlex-Pipe loops Length per loop 90m Each loop covers approx. 12m 2 CU 518-MW to control the water temp. in the manifold 90 0 Black Angle X 2 per loop Hooks: 180 units per loop Measurements ADU 3-4 4X90/16 KIT 800X800X kg Thermostat optional Measurements 490X520X120-13kg 29

30 ADU ACU S An alternative to installing Dowlex-Pipes in the floor: ADU 3-4 loop can be connected to 4 ACU s 9000 Btu to heat up to 4 rooms. ADU 3-4 Loop Active Distribution Unit assembled with: Circulation Pump 25W-230V Pressure Gauge Mini-Tank made of 1 stainless steel Manifold 3/4' made of brass Expansion Tank Electrical Unit 15.6 Amp 3X1200W Control Box includes Terminals Flow Valve to allow hot water to the manifold and Dowlex-Pipe Coupling System especially for 16/2mm Dowlex-Pipe Mounted on a 1.5mm Metal Sheet Measurememts: 4900X520X120 13kg Covered by ABS casing ACU (air circulation unit) 5 Speed Air Flow 9000 Btu Very low noise level 30

31 ADU 1-2 4X3/8 KIT A Stand alone system with electrical heating element or can be connected to an existing heating source Up to 12m 2 for one large area or a few small rooms Active Distribution Unit: Circulating Pump 25W 230V Pressure Gauge Mini-Tank made of stainless steel Manifold 3/4' made of brass Expansion Tank Electrical Unit 13 Amp 3X1000W Control Box includes terminals Flow Valve to allow hot water to the manifold and the Dowlex-Pipe mat Coupling System especially for the 8mm Dowlex-Pipe Mounted on a 1.5mm metal sheet Covered by ABS casing Measurments: 490x520x kg Pro Pipe Mat: 8mm Dowlex loops integrated onto mats Mat size 0.50x6.0 Each mat covers 3m Black Angle X 2 per loop Thermostat: CU 518MF To control the water temp. in the manifold On/Off Switch Advantages: Energy saving Low temperature floor heating (max.45 C) Easy to install Built up of only 10mm floor height The Kit includes: ADU 1-2 4X3/8 4 Dowlex-Pipe mats CU 518-MF Packaging measurments: 520x540x650-33kg 31

32 ADU 1-2 4X4/8 KIT A Stand alone system with electrical heating element or can be connected to an existing heating source Up to 12m 2 for one large area or a few small rooms Active Distribution Unit: Circulating Pump 25W 230V Pressure Gauge Mini-Tank made of stainless steel Manifold 3/4' made of brass Expansion Tank Electrical Unit 13 Amp 3X1000W Control Box includes terminals Flow Valve to allow hot water to the manifold and the Dowlex-Pipe mat Coupling System especially for the 8mm Dowlex-Pipe Mounted on a 1.5mm metal sheet Covered by ABS casing Measurments: 490x520x kg Pro Pipe Mat: 8mm Dowlex loops integrated onto mats Mat size 0.50x8.0 Each mat covers 4m Black Angle X 2 per loop Thermostat: CU 518MF To control the water temp. in the manifold On/Off Switch Advantages: Energy saving Low temperature floor heating (max.45 C) Easy to install Built up of only 10mm floor height The Kit includes: ADU 1-2 4X4/8 4 Dowlex-Pipe mats CU 518-MF Packaging measurments: 520x540x650-33kg 32

33 FRC KIT Mainly for bathrooms Floor Room Control To be installed in an appropriate position in the wall Controlled with a floor sensor thermostat To be connected to the home central heating system Mounted into a box for wall integrated installation Two adapters for the 8mm Dowlex-Pipe mat - inlet and outlet Size: 24x14.5x95 Dowlex-Pipe Mat: 8mm Dowlex-Pipe integrated onto mats Mat sizes of 1 or 2 of 3m Black Angle X 2 per loop Thermostat: CU 518MF To control the water temp. On/Off Switch External temperature sensor Sensor pipe Advantages: Easy installation Normal thermostat to control Floor build up of only 10mm The Kit includes: FRC installed in a box 1x Dowlex-Pipe mat CU 518 MF Packaging measurements 260x160x100mm 33

34 RTL-U Kit No electrical connections Mainly for bathrooms RTL To be installed in an appropriate position in the wall To be connected to the home central heating system Mounted into a box for wall integrated installation Size: 24x14.5x95 Dowlex-Pipe Mat: 8mm Dowlex-Pipe integrated onto mats Mat sizes of 1 or 2 of 3m Black Angle Dowlex-Pipe Mat: 8mm Dowlex-Pipe integrated onto mats Mat size 0.50x6.0 Each mat covers 3m Black Angle X 2 per loop Advantages: Easy installation Floor build up of only 10mm The Kit includes: RTL installed in a box 1x 8mm Dowlex-Pipe mat Packaging measurements: 260x160x100mm 34

35 PDU Basic KIT Passive distribution unit connects to an existing heat source. Up to 12m 2 for one large area or a few small rooms. Passive Distribution Unit Circulating Pump 25W 230V Pressure Gauge Manifold 3/4 made of brass Control Box includes Limitor CU C Coupling System especially for 8mm Dowlex-Pipe mat Mounted on a 1.5mm metal sheet Covered by ABS casing Inlet valve for conected to Hot water source Thermostat: CU 510 To control the water temp.(22-35 C ) in the Manifold. connected to room thermostat option On/Off Switch Advantages: Low temperature floor heating (max.45 C) Energy saving Easy to install Built up of only 10mm floor height The Kit includes: PDU Basic 4x 8mm Dowlex-Pipe loops integrated on to the mats Mat size 0.50X6.0 Each mat covers 3m Black Angles X 2 per loop 35

36 SDU Z-P- 4 loop KIT SDU Z-P- 4Loops As a Zone Heating System Standard Distribution Unit assembled with: Circulation Pump 25W 230V Control box includes terminals Air release valve Made of 1 stainless steel An adjustable flow meter for each loop Each loop includes mechanical valve Suitable for 16/2mm Dowlex-Pipe Mounted in a metal cabinet The Kit includes: SDU Z-P - 4 Manifold Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer Length per loop 90m Each loop covers approx. 12m 2 when spaced at 15cm Clamping rings of 3/4 for 20/2 connection pipe 90 0 Black Angle X 2 per loop Hooks: 180 units per loop Measurements 530X500X110-12kg Thermostat optional Measurements SDU Z-P KIT 800X800X990-62kg 36

37 SDU Z-P-V - 4 loop KIT SDU-Z-P-V As a Zone Heating System Standard Distribution Unit assembled with: Circulation pump 25W 230V Control box includes terminals Air release valve Made of 1 stainless steel An adjustable flow meter for each loop Each loop includes mechanical valve activated by 230V Actuator to open and close water flow in each loop (The actuator is controlled by a thermostat placed in each room) Suitable for 16/2mm Dowlex-Pipe Mounted in a metal cabinet The Kit includes: SDU-Z-P-CU Manifold Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer Length per loop 90m Each loop covers approx. 12m 2 when spaced at 15cm Clamping rings of 3/4 for 20/2 connection pipe 90 0 Black Angle X 2 per loop Thermostat optional Measurements 530X500X110-13kg Measurements SDU Z-P-V KIT 800X800X990-65kg 37

38 SDU Z-R-P-V loops Standard Distribution Unit assembled with: Water Circulation pump 25W 230V For each loop: Adjustable Flow Meter - Mechanical Valve 230V - 3/4 Clamping Ring Electrical Terminal Box to wire the Electrostatic Valve to the Room Thermostat and Pump Switch on it. Air Release Valve Made of 1 stainless steel Actuator to open and close water flow in each loop is controlled by thermostat (NOT INCLUDED) placed in each room/area. Suitable for 16/2mm Dowlex-Pipe Mounted on a Plated Metal Sheet 1.5mm thick Mounted in a Header Cabinet (Optional) Covered by ABS casing 4 x 6mm holes for mounting the SDU Z-Y-P-V on the wall The Kit includes: SDU-Z-P-V 4+1 Loops Manifold Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer Length per loop 90m Each loop covers approx 12m 2 14m 2 Clamping rings of 3/ Black Angle X 2 per loop Hooks: 180 units per loop 4 Screws and plastic plugs are attached to the kit Measurements SDU-Z-R-P-V 4+1 Loops 530X500X110-13kg CU 333 (Optional) Measurements SDU-Z-R-P-V KIT 800X800X990-65kg 38

39 SDU Z-Y-P-V-8+2 Loops KIT Standard Distribution Unit assembled with: For each loop: Adjustable Flow Meter - Mechanical Valve 230V - 3/4 Clamping Ring Whirl Pump 65/W - 230V Control Box includes terminals and Pump Switch Electrical Terminal Box to wire the Electrostatic Valve to the Room Thermostat Air Release Valve Made of 1 stainless steel Actuator to open and close water flow in each loop is controlled by thermostat (NOT INCLUDED) placed in each room/area. Suitable for 16/2mm Dowlex-Pipe to connect to floor heating Mounted on a Plated Metal Sheet 1.5mm thick Mounted in a Header Cabinet (Optional) Covered by ABS casing 4 x 6mm holes for mounting the SDU Z-Y-P-V on the wall The Kit Includes: SDU Z-Y-P-V 8+2 Loops Manifold Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer Length per loop 90m Each loop covers approx. 12m 2 14m 2 Hooks: 180 units per loop 90 0 Black Angle x 2 per loop 4 Screws and plastic plugs are attached to the kit. Measurements SDU Z-Y-P-V 8+2 Loops 900X650X160-23kg CU 333 (Optional) Measurements SDU Z-Y-P-V-KIT 1300X800X kg 39

40 PDU-HP 6 Loops KIT Passive Distribution Units- HP Passive Distribution Unit assembled with: Circulating Pump 65/W - 230V. Pressure Gauge. Mini-Tank made of stainless steel. Electrical Element 230V 3X(different outputs available). Electrical Box including Terminals, Switches & Contactor. Valve to allow flow of hot water to the manifold & Dowlex-Pipe. Air Release Valve. Controlled By-Pass. Made of stainless steel 1. Manifold includes for each loop adjustable flow meter. Each loop includes Mechanical Valve activated by 230V. Actuator to open and close water flow in each loop. (The actuator is controlled by a thermostat placed in each room). Suitable for Dowlex-Pipe 16/2. Each loop includes 3/4 Clamping Ring. Mounted on a Plated Metal Sheet 1.5mm thick. Covered by ABS casing. 4 x 8mm holes for mounting PDU HP on the wall. The Kit Includes: Dowlex-Pipe 16/2 made of Dowlex and has an oxygen barrier layer. Length per loop 90m Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm. Hooks: 180 units per Loop Black Angle x 2 per loop. 4 Screws and Plastic Plugs are attached to the kit. Measurements PDU HP - 4 loops 750X650X130-19kg PDU HP - 6 loops 900X650X kg PDU HP - 8 loops 1000X650X kg Measurements PDU HP - Kits 4 loops 800X800X kg 6 loops 1300X800X790-95kg 8 loops 1300X800X kg 40

41 PDU-ET 6 Loops KIT Passive Distribution Unit assembled with: For each loop: Adjustable Flow Meter - Mechanical Valve 230V - 3/4 Clamping Ring Circulating Pump 65/W - 230V Pressure Gauge Mini-Tank made of stainless steel Expansion Tank Electrical Element 230V 3X(different outputs available) Electrical Box including Terminals, Switches & Contactor Flow Valve to allow hot water to the manifold & Dowlex- Pipe Air Release Valve Controlled By-Pass Made of 1 stainless steel Actuator to open and close water flow in each loop The actuator is controlled by a thermostat placed in each room Suitable for 16/2mm Dowlex-Pipe Mounted on a Plated Metal Sheet 1.5mm thick Covered by ABS casing 4 x 8mm holes for mounting the PDU ET on the wall The Kit Includes: Dowlex-Pipe 16/2mm made of Dowlex with an oxygen barrier layer 4, 6, 8, 10 loops Length per loop 90m Each loop is calculated to cover apprx. 12m 2 when spaced at 15cm Hooks: 180 units per Loop 90 0 Black Angle x 2 per loop 4 Screws and Plastic Plugs are attached to the kit Measurements PDU ET - 4 loops 750X650X130-19kg PDU ET - 6 loops 900X650X kg Measurements PDU ET - Kits 4 loops 800X800X kg 6 loops 1300X800X790-95kg 41

42 Air Circulation Unit - ACU DESCRIPTION & FEATURES: Controlled water temperature, heated or cooled by the Energy Unit & Heat Pump-B is constantly circulated in the copper pipes of the ACU (Air Circulation Unit) Includes a filter which will maintain a clean and dust free environment Can be installed on walls at heights that will still give architects the advantages as in floor heating systems. Gently and quietly circulates the air at a speed set by the home owner Includes a remote control The ACU has 5 speed air flow 9000 or Btu are available Very low noise level TECHNICAL DATA: Characteristics Operation voltage Electric Power Operation pressure (Bar) Water Flow / Hour (L/h) Noise Level (dba) Weight (kg) Dimensions (mm) Nominal Air Flow Rate (m³/h) 9000 Btu 230V AC 50Hz 35W < x 320 x Btu 230V AC 50Hz 35W > x 320 x

43 ACU - Floor OS DESCRIPTION & FEATURES: The Climateck ACU - Floor OS integrates the air conditioning system with a heating system in a single terminal In winter it is silent as a radiator, but offers a much higher performance In the summer it is an exceptional air conditioner, that cools and dehumidifies Extra thin dimensions that makes it suitable for any context - less than 13cm depth Can be operated on 3 different speeds of air flow Very low noise level 9000 Btu Includes a remote control TECHNICAL DATA: Characteristics Operation voltage Electric Power Operation pressure (Bar) Water Flow / Hour (L) Noise Level (dba) Weight (kg) Dimensions (mm) Air Flow Rate (Min. - Max. in m³/h) ACU - Floor OS (9000 Btu) 230V AC 50Hz 55W < x 897 x

44 ACU-Ceiling AIR CIRCULATION UNIT APPLICALBLE FOR : HOTELS OFFICES COMMERCIAL BUILDINGS RESIDENTIAL HOMES DESCRIPTION & FEATURES: The Climateck ACU-Ceiling is an air circulation system installed & concealed within the ceiling. The advantage of it being built-in, it provides aesthetics and takes up no space. Winter season - works as a silent radiator at a high performance. Summer season - cools and dehumidifies. Climateck s ACU-Ceiling has a four-way air flow with availability of 60 downward fanning and swing action. Operated by remote control (included). Climateck s ACU-Ceiling gives a uniform distribution of heated or cool air, creating a comfortable environment. Ultra thin body saves installation space - Simple filter easy for cleaning. Climateck s ACU-Ceiling has a luxurious appearance making ideal for: Restaurants Entertainment places Meeting rooms Supermarket TECHNICAL DATA: Characteristics Nominal Capacity Cooling Heating ACU Ceiling 10747BTU/h BTU/h Operation voltage Max. Input Power (W) Operation pressure (Bar) Nominal Air Flow Rate (m³/h) (at high fan speed) Water Flow (L/Hour) Noise Level (dba) Weight (kg) V/50Hz/1Ph Dimensions (mm) Main body ABS panel 580x580x x650x30 44

45 SDU A for ACU Standard Distribution Unit assembled with: SDU A - 5Loops A Blank Port (capped) Made of 1 stainless steel Suitable for 16/2mm Dowlex-Pipe 4 x 8mm holes for mounting SDU-A on the wall Mounted on a Plated Metal Sheet (1.5mm thick) Adapter Measurements: SDU A - 3 loops 450 X 250 X 10 SDU A - 4 loops 450 X 300 X 10 SDU A - 5 loops 450 X 350 X 10 45

SDU A. SDU A Loops. (available in 3, 4, 5 loops) Water Based Systems. Standard Distribution Unit assembled with: A Blank Port (capped)

SDU A. SDU A Loops. (available in 3, 4, 5 loops) Water Based Systems. Standard Distribution Unit assembled with: A Blank Port (capped) 3102 SDU A Standard Distribution Unit assembled with: A Blank Port (capped) SDU A - 3-5 Loops (available in 3, 4, 5 loops) Made of 1 stainless steel Suitable for 16/2mm Pro-Pipe 4 x 8mm holes for mounting

More information

FLOOR WARMING PRODUCTS. For more ALL PICTURES & GRAPHICS ARE FOR ILLUSTRATION ONLY

FLOOR WARMING PRODUCTS. For more ALL PICTURES & GRAPHICS ARE FOR ILLUSTRATION ONLY 3102 A very warm welcome to The Decora Group the management and holding company for Domoteck and Climateck Industries. Focusing on making modern living comfortable, the Decora group has developed some

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling

More information

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9

More information

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE

More information

Catalogue 2015 AMITIME ELECTRIC CO., LTD Add: Yandong 5th Rd, Dayan Industrial Zone, Huangpu Town, Zhongshan City, Guangdong, China Tel: 86-760-23973810 Fax: 86-760-23973813 Email: info@amitime.com Http://www.amitime.com

More information

DOMOTHERM CLASSIC TWIN/S MAT

DOMOTHERM CLASSIC TWIN/S MAT Floor warming products 2013 V 10.12.2012 DOMOTHERM CLASSIC TWIN/S MAT An ideal solution for the whole house Ultra thin cable (2mm) Energy efficient Easy to install Domotherm Twin/s can be installed under:

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure

More information

2 &3-4 Head Multi System

2 &3-4 Head Multi System 2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy

More information

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA A GUIDE TO COMFORT HITACHI INVERTER SPLIT SYSTEMS Enjoy the Silence with Quiet Mode With Hitachi, noisy air conditioners are a thing of the past. Our modern Full Flat design has ensured efficient yet ultra-quiet

More information

Thermotech underfloor heating

Thermotech underfloor heating Thermotech underfloor heating Assortment and pricelist 2010 Copyright: Thermotech Scandinavia AB 2009 Cover photo: Michael Engman Graphic design: Ulrika Mattisson Other image material: Michael Engman,

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

LG VRF Systems. Air Conditioning Technologies

LG VRF Systems. Air Conditioning Technologies LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior

More information

Multi Inverter Air Conditioning Condensing Units - Summary

Multi Inverter Air Conditioning Condensing Units - Summary Multi Inverter Air Conditioning Condensing Units - Summary Model Description Nominal Max of Cooling Inverter No. Heating of (kw) Fan Condensing (kw) Coils Unit ECO18MS2 Twin Multi Inverter 5kW 5.2 6.1

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation. Installation Manual Electric Underfloor Heating heatingthroughinnovation. 02 Electric Underfloor Heating Contents 1.0 General Information 03 2.0 Preparation 04 3.0 Installation 05 4.0 Measuring Values

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

Electricity Consume of Solar AC VS Normal AC

Electricity Consume of Solar AC VS Normal AC GLOBAL ENERGY COLLABORATIONS GLO-SUN Solar Air Conditioners [220V- 50Hz range] Split Type >>KFR-35GW (12000BTU) Reinforced refrigeration Thin and slim design Warm startup(cold air prevention) Independent

More information

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round AIR TO WATER HEAT PUMPS Hot water and comfortable ambient temperature all year round HEAT PUMP PRINCIPLE CARRIER. A UNITED TECHNOLOGIES COMPANY Whether you need air conditioning for a new building or a

More information

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners V-Series Mid-Size Air Conditioners (Now done by MGDC) VA08 Indoor Model 1200, 1500 and 2000 Watts INDUSTRY STANDARDS IP 56 Internal Air Loop IP 34 External Air Loop APPLICATION Industrial drive enclosures

More information

Multilux 4-Eclipse-Set

Multilux 4-Eclipse-Set Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux

More information

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED Just feel well Renewable Energy MADE IN EUROPE A ++ + PRODUCTS High efficiency: ηs %. High flexibily due to DC Inverter compressor: operation optimised

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW Fan coil ART-U NEW PRODUCT Design fan coil unit with a minimum depth of 10 cm only and BLDC motor ART-U 1-4 kw Available from SEPTEMBER 2018 Design-driven innovation BLDC motor Tangential fan Supervision

More information

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS The latest innovation in cool 7 YEAR WARRANTY ON COMPRESSORS 1 YEAR WARRANTY ON PARTS Engineered to be both aesthetically pleasing and energy-efficient, Katashi air conditioning units bring the latest

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

S-Therm Air to Water Heat Pumps

S-Therm Air to Water Heat Pumps S-Therm Air to Water Heat Pumps AIR TO WATER HEAT PUMP Air to water heat pump Nowadays, people are increasingly focusing on the cost of heating as well as on environmental issues. Traditional heating systems

More information

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair. WALL-MOUNTED HEAT PUMPS SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) UP TO 23 SEER UP TO 11 HSPF HEATING UP TO -20 C 10 years* *See details on the back Warranty Exclusive distributor in Quebec descair.ca What

More information

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q *** PRODUCT BULLETIN Estia Air to Water Heat Pump 5 Series w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q4 2017 *** are pleased to announce the production of the NEW Estia

More information

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners 763.576.3200 SPEC-00747 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES MID-SIZE AIR CONDITIONERS VA08 Indoor Model 1200, 1500 and 2000

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. Centrifugal fancoils for surface mounting or recessed installation. Cooling capacity from 0,6 to 7,6 kw and heating capacity from 0,8 to 9 kw. Air flow from 100 to 1500 m3/h. Cassette with radial fan.

More information

Always make sure to check the heating film before, during, and after installation of the floor covering.

Always make sure to check the heating film before, during, and after installation of the floor covering. Installation of floor heating film for ceramic tiles, granite and other stone or composite flooring Read through this entire manual before starting installation. All electrical connections must be made

More information

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. The DRY-30 Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

Call or visit solarshop.com.au

Call or visit solarshop.com.au Solar HYBRID AIR CONDITIONING Call 133 765 or visit solarshop.com.au Copyright 2012, Solarshop Group Pty Ltd. The contents of this brochure are protected by copyright law. Copyright in this material resides

More information

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. The DRY-40A Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

EVAPORATIVE COOLER PUMPS

EVAPORATIVE COOLER PUMPS EVAPORATIVE COOLER PUMPS ebmpapst Evaporative Cooler Pump EBMALPHA $144.65 @ 1. metre Head @ 2. metre Head Power Supply 32 litres/min 25 litres/min 24V/1/5Hz Nominal Watts 5 watts Outlet Connection 2mm

More information

QTS SELECTION TECHNICAL BOOKLET

QTS SELECTION TECHNICAL BOOKLET EN QTS SELECTION TECHNICAL BOOKLET Bi2 FAN RADIATORS AND FAN COILS Italian company established in 1956 2 Bi2 Bi2 TABLE OF CONTENTS 1 Range of system terminals... 6 1.1 Cabinet system terminals... 6 1.2

More information

Toll Free:

Toll Free: 1 ProLine s electric radiant floor heating system is one of the most popular and durable floor heating solutions on the market. Available pre-spaced in mats with an adhesive backing or on the spool, the

More information

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy

More information

4 1 Heating. wooden floors or renovated floors.

4 1 Heating. wooden floors or renovated floors. 4 1 Heating 1.1 General information DEVI s floor heating systems consist of deviflex heating cables or devimat heating mats, devireg temperature regulation thermostats, and installation accessories. The

More information

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual Version 1.5 1 CONTENTS CHAPTER 1 GENERAL INTRODUCTION...3 1. Preface... 3 2. Product Introduction... 3

More information

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit 2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water

More information

JUNE & 3-4 Head Multi System

JUNE & 3-4 Head Multi System JUNE 2008 2 & 3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities

More information

Thermal management for your cabinets!

Thermal management for your cabinets! ELECTRIC CABINET HEATERS LIGHTS CONTROLLER ELECTRIC CABINET COOLERS Thermal management Thermal management for your cabinets! MORE THAN 55 YEARS the specialist for individual electric cabinet heaters and

More information

Wall Mounted Split Systems

Wall Mounted Split Systems MWM - 2005 Wall Mounted Split Systems Models: MWM 007F/FR MWM 010F/FR MWM 015F/FR MWM 020F/FR MWM 025F/FR MWM 030F/FR Contents Features... 1 Nomenclature... 2 Specifications... 3 Performance Table... 11

More information

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC COLD CLIMATES REFERRING SPECIFICALLY TO CLIMATES ZONES 6 & 7 HYDRONIC HEATING USING A FLUID TO TRANSFER

More information

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER AIR CONDITIONER manufactured with latest inverter Technology 97% of operating power from solar energy very low Power consumption levels Eco-friendly, reduced

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

... Air Conditioners & Heat Pumps Light Commercial ...

... Air Conditioners & Heat Pumps Light Commercial ... ... Air Conditioners & Heat Pumps Light Commercial... Mini Split Mini Split Systems Single-zone mini-splits allow easy addition of heating and cooling to specific areas. Space additions, hot and cold spots,

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings The new i-life Slim fan coil, with inverter technology for heating, cooling and dehumidifying. Its elegant design with only 13 cm depth makes i-life Slim the perfect solution for residential applications.

More information

13 SEER CONDENSING UNITS & AIR HANDLERS

13 SEER CONDENSING UNITS & AIR HANDLERS 13 SEER CONDENSING UNITS & AIR HANDLERS (GC201305-I) TTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CON TECHNICAL SALES GUIDE-60Hz CAPACITY RANGE:11/2~5

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating 2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial

More information

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP 1 Enjoy comfortable life with BLUEWAY DC Inverter Air to Water Heat Pump is an innovative system of house heating, domestic hot water and even space cooling,

More information

Inverter Ducted XPower 42QSS

Inverter Ducted XPower 42QSS 3D DC Inverter Timer Sleep Mode Turbo Mode Auto Leak Detection 49 Compact and versatile is the ideal choice for new or refurbished buildings Key Features EUROVENT CERTIFIED PERFORMANCE: Eurovent Certification

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion

More information

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO FIXED AIR CONDITIONERS PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO FIXED AIR CONDITIONERS PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS 136 PORTABLE AIR FIXED AIR UNICO AIR COOLER SYSTEM TERMINAL UNITS HEAT PUMPS SiOS FIXED AIR S 137 PELLET STOVES GAS STOVES VMC DEHUMIDIFIERS HUMIDIFIERS FAN HEATERS CERAMIC FAN HEATERS PERSONAL COMFORT

More information

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers : SINGLEPACKAGE CONSOLE UNITS, MONOSPLIT, AIR CONDENSING UNITS APPLICATIONS COMMERCIAL SECTOR CONSOLE UNITS AIR CONDENSING UNITS Always very much appreciated for special installations these units shown their

More information

Heating Installation Guide published by

Heating Installation Guide published by Heating Installation Guide published by MrPEX Systems 2613 87th Court W. Northfield, MN 55057 800-716-3406 mrpexsystems.com mrpex@mrpexsystems.com 2014 MrPEX Systems All rights reserved Printed September

More information

WATCH OUT! UNDERNEATH THE WOODEN FLOORING IS A 230 VOLT HEATING FOIL SYSTEM! NEVER DRILL OR SCREW INTO THE FLOOR!

WATCH OUT! UNDERNEATH THE WOODEN FLOORING IS A 230 VOLT HEATING FOIL SYSTEM! NEVER DRILL OR SCREW INTO THE FLOOR! WATCH OUT! UNDERNEATH THE WOODEN FLOORING IS A 230 VOLT HEATING FOIL SYSTEM! NEVER DRILL OR SCREW INTO THE FLOOR! SEE SCHEDULE/PICTURE FOR THE POSITION OF THE KLIMA FOIL. Control measurements: Type foil

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

UNDERFLOOR HEATING GUIDE

UNDERFLOOR HEATING GUIDE UNDERFLOOR HEATING GUIDE Bringing you the best underfloor heating in South Australia for 30 years. Introduction to Underfloor Heating Due to its supreme level of comfort and great heating efficiency, underfloor

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Air Conditioning & Heating. Ductless Heating & Cooling Systems

Air Conditioning & Heating. Ductless Heating & Cooling Systems Air Conditioning & Heating Ductless Heating & Cooling Systems Ductless Heating & Cooling Systems What Is Ductless? What Is Ductless? It s comfort wherever and however you need it. With a Comfortmaker Ductless

More information

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3

More information

Do you want a versatile solution

Do you want a versatile solution Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS INSTALLATION INSTRUCTIONS FOR CONTROL BOXES Pay attention to the total pressure loss when connecting UV4- to the control boxes for heating areas > 16 m²!

More information

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS CONTENTS Overview 2 Features & Benefits 3 Performance 4 Accent Pool Water to Water Heat Pumps Technical 5 Accent Hot Water Water to Water Heat Pumps Technical

More information

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment

More information

A new age in HEATING. ROTEX Monopex The natural way to save energy! The complete heating system

A new age in HEATING. ROTEX Monopex The natural way to save energy! The complete heating system R A new age in HEATING R eco Systems - ROTEX EcoHybrid Heating for your home all from one source The complete heating system - Regenerative air-water Heating Pump - Modern burning Technique - Solar power

More information

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA... FIXED FREQUENCY U-MATCH AIR CONDITIONERS TECHNICAL SALES GUIDE Capcity Range: 18000~ 60000 Bth h T3R2250Hz CONTENTS 1. MODELS LIST... 3 2. NOMENCLATURE... 4 3. FEATURES... 5 4. PRODUCT DATA... 9 5. FAN

More information

UNDERFLOOR HEATING EXPRESS. UK s Water & Electric Underfloor Heating Supplier

UNDERFLOOR HEATING EXPRESS. UK s Water & Electric Underfloor Heating Supplier UK s Water & Electric Underfloor Heating Supplier CATALOGUE 2017 Electric Underfloor Heating Water Underfloor Heating Manifolds & Pumps Insulation Boards Thermostats & Controls Accessories Underfloor Heating

More information

INVERTER 9-12 DC INVERTER 9 SF

INVERTER 9-12 DC INVERTER 9 SF INVERTER 9-12 DC 1. TECHNICAL DATA: DESCRIPTION OF PARAMETERS INVERTER 9 SF INVERTER 9 HP INVERTER 12 SF INVERTER 12 HP Cooling capacity (1) (min / rated / max) kw 1.4/2.3/2.7 1.4/2.3/2.7 1.8/2.7/3.1 1.8/2.7/3.1

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

Standard Inverters FUNCTION COMFORTABLE AIR FLOW CONVENIENT & ECONOMY MAINTENANCE & PREVENTION OTHERS

Standard Inverters FUNCTION COMFORTABLE AIR FLOW CONVENIENT & ECONOMY MAINTENANCE & PREVENTION OTHERS Standard Inverters SRK-ZJ (2.5-5.0 kw) Packed with features and the latest technologies in room air conditioning, the SRK Standard Inverter range offers energy efficient cooling and heating for individual

More information

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL

More information

Inverter console UFV system. Compact design and personalised air flow selection

Inverter console UFV system. Compact design and personalised air flow selection Inverter console UFV system Compact design and personalised air flow selection 2 Efficient and reliable system Thanks to Toshiba DC Hybrid Inverter technology the system operates at maximum capacity in

More information

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide Simple. Smart. Solutions. ROOM PACK Z2105/239/0812 Step by Step Installation Guide 1. Room Pack Overview 2. Temperature Settings 3. Operation 4. Wiring 5. Installing Your Room Pack Before you get started

More information

Split Type System. Air to Water Heat Pump

Split Type System. Air to Water Heat Pump Split Type System Air to Water Heat Pump EXPERTISE AND INNOVATION Daikin Altherma offers complete flexibility for new construction and deep energy refurbishment projects. Using a low temperature hydronic

More information

Air conditioners, heating & cooling for the retailmarket and offices

Air conditioners, heating & cooling for the retailmarket and offices Air conditioners, heating & cooling for the retailmarket and offices floor standing unit air to air heat pumps www.daikin.eu FVQ-B MAXIMUM RELIABILITY, MINIMUM ENERGY USE Advanced climate systems in modern

More information

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL FloorHeat PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL Thank you for purchasing this radiant control panel assembly. Following are some important notes that will make the installation successful.

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of

More information

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles MINI-SPLIT STANDARD AIR CONDITIONERS SINGLE ZONE Mini-Split Standard systems utilize the same duct-free technology as Art Cool units in a streamlined, low profile design. Models are available in a variety

More information

Condensate water pumps

Condensate water pumps Condensate water pumps Welcome! If reliability is your main concern, then you finally have the right document in your hand. Among our big range of condensate pumps you will certainly find the one matching

More information

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation Eclipse Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse Eclipse The thermostatic

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET AUTO COOL DRY MODE TIMER ON OFF TIMER OFF/ON TEMP ON TIMER FAN SPEED AIR SWING SET 1 2 3 FAN SPEED AIR SWING OFF CANCEL AC RC SET CHECK CLOCK RESET Order No: PAPAMY1611008CE Indoor Unit CS-MPS9SKH CS-MPS12SKH

More information