PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

Size: px
Start display at page:

Download "PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED"

Transcription

1 Ministry of Municipal Affairs PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED CHANGE NUMBER: SOURCE: B Ontario-NBC CODE REFERENCE: Division B / and DESCRIPTION OF THE PROPOSED AMENDMENT This proposed change would permit the use of a residential warning system in lieu of an interconnected smoke alarm system. This new system allows the connection of heat detectors, CO alarms, other life safety devices and remote monitoring capabilities. It is also capable of supervising the interconnected devices. EXISTING 2012 BUILDING CODE PROVISION(S) Smoke Alarms (1) Except as permitted by Sentence (6), smoke alarms conforming to CAN/ULC-S531, Smoke Alarms, shall be installed in each dwelling unit and, except for care, care and treatment or detention occupancies required to have a fire alarm system, in each sleeping room not within a dwelling unit. (2) At least one smoke alarm shall be installed on each storey and mezzanine of a dwelling unit. (3) On any storey of a dwelling unit containing sleeping rooms, a smoke alarm shall be installed in, (a) each sleeping room, and (b) a location between the sleeping rooms and the remainder of the storey, and if the sleeping rooms are served by a hallway, the smoke alarm shall be located in the hallway. (4) A smoke alarm shall be installed on or near the ceiling. (5) Except as permitted by Sentence (6), smoke alarms required by Sentence (1) shall, (a) be installed with permanent connections to an electrical circuit, (b) have no disconnect switch between the overcurrent device and the smoke alarm, and (c) in case the regular power supply to the smoke alarm is interrupted, be provided with a battery as an alternative power source that can continue to provide power to the smoke alarm for a period of not less than seven days in the normal condition, followed by 4 min of alarm. (See Appendix A.) (6) Suites of residential occupancy are permitted to be equipped with smoke detectors in lieu of smoke alarms, provided the smoke detectors, (a) are capable of independently sounding audible signals within the individual suites, (b) except as provided by Sentence (7), are installed in conformance with CAN/ULC-S524, Installation of Fire Alarm Systems, and verified in conformance with CAN/ULC-S537, Verification of Fire Alarm Systems, and (c) form part of the fire alarm system. Building and Development Branch Page 1

2 (7) Smoke detectors permitted to be installed in lieu of smoke alarms as provided in Sentence (6) are not required under Clause (6)(b) to sound an alarm throughout the rest of the building, provided they sound localized alarms within individual suites and otherwise meet the requirements of Clause (6)(b). (See Appendix A.) (8) If more than one smoke alarm is required in a dwelling unit, the smoke alarms shall be wired so that the actuation of one smoke alarm will cause all smoke alarms within the dwelling unit to sound. (9) A smoke alarm required by Sentence (1) shall be installed in conformance with CAN/ULC-S553, Installation of Smoke Alarms. (10) Except as permitted by Sentence (11), a manually operated silencing device shall be incorporated within the circuitry of a smoke alarm installed in a dwelling unit so that it will silence the signal emitted by the smoke alarm for a period of not more than 10 min, after which the smoke alarm will reset and again sound the alarm if the level of smoke in the vicinity is sufficient to reactuate the smoke alarm. (11) Suites of residential occupancy equipped with smoke detectors installed in conformance with CAN/ULC-S524, Installation of Fire Alarm Systems, as part of the fire alarm system in lieu of smoke alarms as permitted by Sentence (6), need not incorporate the manually operated silencing device required by Sentence (10). (12) The sound patterns of smoke alarms shall, (a) meet the temporal patterns of alarm signals, or (b) be a combination of temporal pattern and voice relay. (13) Smoke alarms required by Sentence (1) shall have a visual signalling component conforming to the requirements in (Light, Color and Pulse Characteristics) of NFPA 72, National Fire Alarm and Signaling Code. (See Appendix A.) (14) The visual signalling component required by Sentence (13) need not, (a) be integrated with the smoke alarm provided it is interconnected to it, (b) be on battery backup, or (c) have synchronized flash rates, when installed in a dwelling unit. (15) The luminous intensity for visual signalling components required by Sentence (13) that are installed in sleeping rooms shall be a minimum of 175 cd Voice Communication Systems PROPOSED CODE CHANGE Revise existing Article and add new Article as follows: Smoke Alarms (1) Except as provided in Article smoke alarms shall be installed in accordance with this Article. (12) Except as permitted by Sentence (7), smoke alarms conforming to CAN/ULC-S531, Smoke Alarms, shall be installed in each dwelling unit and, except for care, care and treatment or detention occupancies required to have a fire alarm system, in each sleeping room not within a dwelling unit. (23) At least one smoke alarm shall be installed on each storey and mezzanine of a dwelling unit. (34) On any storey of a dwelling unit containing sleeping rooms, a smoke alarm shall be installed in, (a) each sleeping room, and (b) a location between the sleeping rooms and the remainder of the storey, and if the sleeping rooms are served by a hallway, the smoke alarm shall be located in the hallway. Building and Development Branch Page 2

3 (45) A smoke alarm shall be installed on or near the ceiling. (56) Except as permitted by Sentence (7), smoke alarms required by Sentence (2) shall, (a) be installed with permanent connections to an electrical circuit, (b) have no disconnect switch between the overcurrent device and the smoke alarm, and (c) in case the regular power supply to the smoke alarm is interrupted, be provided with a battery as an alternative power source that can continue to provide power to the smoke alarm for a period of not less than seven days in the normal condition, followed by 4 min of alarm. (See Appendix A.) (67) Suites of residential occupancy are permitted to be equipped with smoke detectors in lieu of smoke alarms, provided the smoke detectors, (a) are capable of independently sounding audible signals within the individual suites, (b) except as provided by Sentence (8), are installed in conformance with CAN/ULC-S524, Installation of Fire Alarm Systems, and verified in conformance with CAN/ULC-S537, Verification of Fire Alarm Systems, and (c) form part of the fire alarm system. (78) Smoke detectors permitted to be installed in lieu of smoke alarms as provided in Sentence (7) are not required under Clause (7)(b) to sound an alarm throughout the rest of the building, provided they sound localized alarms within individual suites and otherwise meet the requirements of Clause (7)(b). (See Appendix A.) (89) If more than one smoke alarm is required in a dwelling unit, the smoke alarms shall be wired so that the actuation of one smoke alarm will cause all smoke alarms within the dwelling unit to sound. (910) A smoke alarm required by Sentence (2) shall be installed in conformance with CAN/ULC-S553, Installation of Smoke Alarms. (1011) Except as permitted by Sentence (12), a manually operated silencing device shall be incorporated within the circuitry of a smoke alarm installed in a dwelling unit so that it will silence the signal emitted by the smoke alarm for a period of not more than 10 min, after which the smoke alarm will reset and again sound the alarm if the level of smoke in the vicinity is sufficient to reactuate the smoke alarm. (1112) Suites of residential occupancy equipped with smoke detectors installed in conformance with CAN/ULC- S524, Installation of Fire Alarm Systems, as part of the fire alarm system in lieu of smoke alarms as permitted by Sentence (7), need not incorporate the manually operated silencing device required by Sentence (10). (1213) The sound patterns of smoke alarms shall, (a) meet the temporal patterns of alarm signals, or (b) be a combination of temporal pattern and voice relay. (1314) Smoke alarms required by Sentence (2) shall have a visual signalling component conforming to the requirements in (Light, Color and Pulse Characteristics) of NFPA 72, National Fire Alarm and Signaling Code. (See Appendix A.) (1415) The visual signalling component required by Sentence (14) need not, (a) be integrated with the smoke alarm provided it is interconnected to it, (b) be on battery backup, or (c) have synchronized flash rates, when installed in a dwelling unit. (1516) The luminous intensity for visual signalling components required by Sentence (14) that are installed in sleeping rooms shall be a minimum of 175 cd. Building and Development Branch Page 3

4 Residential Fire Warning Systems (1) Except where a fire alarm system is installed or required in a building, smoke detectors forming part of a residential fire warning system installed in conformance with CAN/ULC-S540 Residential Fire Warning Systems: Installation, Inspection, Testing and Maintenance, are permitted to be installed in lieu of all smoke alarms required by Article , provided that the system (a) is capable of sounding audible signals in accordance with Articles and , (b) is provided with a visual signalling component in accordance with Article , (c) is powered in accordance with Article , and (d) is provided with a silencing device in accordance with Article Voice Communication Systems RATIONALE FOR CHANGE Problem/General Background The building official community has requested the use of residential fire warning systems in lieu of the currently required interconnected smoke alarms. The ULC Committee on Fire Alarm and Life Safety Equipment and Systems updated CAN/ULC-S540, Residential Fire Warning Systems: Installation, Inspection, Testing and Maintenance in fall of This standard provides the minimum requirements for the design, installation, inspection, testing and maintenance of residential fire warning systems for use in suites of residential occupancy, dwelling units and care occupancy. Justification/Explanation This proposed change would harmonize requirements with the model National Building Code of Canada. Interconnected smoke alarms and residential fire warning systems will provide detection and audible signals to alert the occupants of an emergency situation. Allowing the option of a residential fire warning system, will enhance the level of life safety provided to the occupants. Additionally, this allows for the interconnection of heat detectors, CO alarms, other life safety devices and remote monitoring capabilities. This will also allow for the supervision of the interconnected devices. Cost/Benefit Implications Since this requirement will be optional, the costs will be minimal and will vary depending on the option chosen. Enforcement Implications This requirement will facilitate enforcement actions by having the reference to a National Standard. Who is Affected Designers, building officials. Building and Development Branch Page 4

5 Objective Based Analysis Provision Objective/Functional Statement Division B (1) [F81,F11-OS1.5] (2) 1 [F11, F81-OS1.5] (3) 2 [F11-OS1.5] (4) 3 [F11-OS1.5] (5) 4 [F11-OS1.5] (6) 5 [F11,F81-OS1.5] (7) 6 [F11,F81-OS1.5] (8) 7 (9) 8 [F11-OS1.5] (10) 9 [F81,F11-OS1.5] (11) 10 [F81,F11-OS1.5] (12) 11 (13) 12 [F11-OS1.5] (14) 13 [F74-OA-2] [F11-OS1.5] (15) 14 (16) 15 [F74-OA-2] [F11-OS1.5] Division B Division B (1) [F11, F12-OS3.7] Building and Development Branch Page 5

6 Provision Objective/Functional Statement (2) [F11-OS1.5] (3) [F11-OS1.5] (4) F11-OS1.5] [F13-OS1.4,OS1.5] (5) [F11-OS1.5] (6) [F12-OS3.7] (7) [F11-OS1.5] (8) [F11-OS1.5] (9) [F11-OS1.5] (10) OTHER SUPPORTING MATERIALS Building and Development Branch Page 6

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED Ministry of Municipal Affairs PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED CHANGE NUMBER: SOURCE: B-03-06-03 Ontario-NBC CODE REFERENCE: Division B / 3.6.4.3. Division B / 9.10.13.14.(1)

More information

CFAA Technical Seminar Ontario Building Code Updates to 2015

CFAA Technical Seminar Ontario Building Code Updates to 2015 CFAA Technical Seminar Ontario Building Code Updates to 2015 October 28, 2015 2015 Fire Alarm Updates Ontario Building Code Glenn Somerton P.Eng. Senior Code Specialist Morrison Hershfield Limited gsomerton@morrisonhershfield.com

More information

PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015)

PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015) PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015) CHANGE NUMBER: CODE REFERENCE: Division B, Sentences 2.13.2.1.(2), 2.13.2.1.(3) DESCRIPTION OF PROPOSED

More information

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety Div B 3.2.1.1.(4), (5) & (6) Exceptions in Determining Building Height BCBC1998-3.2.1.1.(4), (5) & (7) replace (harmonize with NBC) - NBC 2005 has significant revisions to provisions for mezzanines. These

More information

2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014

2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014 2012 OBC Changes Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014 2012 OBC New Sentence 3.2.4.2(6) Buildings interconnected by walkways permitted in Articles

More information

BY-LAW AMENDING THE BY-LAW CONCERNING THE SERVICE DE SÉCURITÉ INCENDIE DE MONTRÉAL (RCG )

BY-LAW AMENDING THE BY-LAW CONCERNING THE SERVICE DE SÉCURITÉ INCENDIE DE MONTRÉAL (RCG ) VILLE DE MONTRÉAL BY-LAW RCG 12-003-1 BY-LAW AMENDING THE BY-LAW CONCERNING THE SERVICE DE SÉCURITÉ INCENDIE DE MONTRÉAL (RCG 12-003) In view of section 62 of the Municipal Powers Act (CQLR, chapter C-47.1);

More information

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE:

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE: Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B-09-32-03 POTENTIAL CHANGE TO ONTARIO S BUILDING CODE: SUMMER AND FALL 2017 CONSULTATION Ministry of Municipal Affairs PROPOSED

More information

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms 2014 Alberta Building Code Part 9 changes relating to Smoke and CO Alarms 9.32.3.9 Carbon Monoxide Alarms What has not changed: 4) & 6) In a residential occupancy containing a fuel burning appliance or

More information

Recent Revisions and Proposed Key Changes to Fire Code

Recent Revisions and Proposed Key Changes to Fire Code Recent Revisions and Proposed Key Changes to Fire Code 2014 CFAA Presentation Kim Bailey - Office of the Fire Marshal and Emergency Management New Section 9.7 Buildings with a Care Occupancy or Retirement

More information

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE Effective Date: 11/01/02 Purpose: MECKLENBURG COUNTY To establish a set of guidelines for performance testing of all newly installed or upgraded fire alarm systems in order to ensure that all devices and

More information

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017 Interim Amendments to Ontario s 2012 Building Code Retirement Homes August 17, 2017 Notice This presentation is intended for general information purposes only. It is not intended as legal or technical

More information

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC) PROPOSED TO THE 2007 FIRE CODE (OFC) PROPOSED OFC Record Division: A Reference Number: 1.4.1.2. DESCRIPTION OF PROPOSED EXISTING OFC PROVISIONS Delete the following definitions: Care or detention occupancy

More information

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS FIRE CODE BULLETIN December 2004 97 FCB 018 (R1) Page 1 of 5 BACKGROUND: MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS Fire protection service companies are

More information

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies 11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies Visible Signals Agenda 1. Physics 2. Installation Considerations

More information

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings Building Standards Advisory Promoting construction of safe, healthy, habitable buildings Saskatchewan Amendments to the National Building Code 2015 In Canada, provincial and territorial governments have

More information

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD Fire alarm and emergency power SPRINKLER HEAD 1 Alert signal Alarm signal Fire detector Heat detector Smoke detector Smoke alarm 1. Detector locations 1. Fire detector locations (3.2.4.11) 2. Smoke detector

More information

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION Ruling No. 02-16-871 Application No. 2002-07 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF Sentence 3.2.4.20.(2)

More information

Clarification. Summary of Changes. Summary of Changes. Alan Cavers Area Manager Fire & Security Systems Group

Clarification. Summary of Changes. Summary of Changes. Alan Cavers Area Manager Fire & Security Systems Group Summary of Changes CAN/ULC-S524-06 Installation of Fire Alarm Systems Alan Cavers Area Manager Fire & Security Systems Group Course Title Rev Date: Summary of Changes Correct Deficiencies noted CAN/ULC-S524-01

More information

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC) TO THE 2007 FIRE CODE (OFC) OFC Record Division: A Reference Number: 1.4.1.2. (dwelling unit) Corresponding NFC Change Division: A Reference Number: 1.4.1.2.(1) OFC Revise definition for Dwelling unit

More information

2012 Ontario Building Code Update

2012 Ontario Building Code Update 2012 Ontario Building Code Update Presented to NORR Dec. 10, 2013 Alek Antoniuk, OAA 2013 Agenda Selected highlights of changes in the 2012 Ontario Building Code related to larger (Pt. 3) buildings O.

More information

Residential Care Facilities Requirements

Residential Care Facilities Requirements Development Services Department Building Division 311 Vernon Street Roseville, California 95678-2649 Residential Care Facilities Requirements SUBMITTAL REQUIREMENTS: Note: These requirements are in addition

More information

Canadian Fire Alarm Association (CFAA)

Canadian Fire Alarm Association (CFAA) An Overview of Changes in the New CAN/ULC-S524-06 Installation of Fire Alarm Systems Canadian Fire Alarm Association (CFAA) CAN/ULC - S524-01 STANDARD FOR THE INSTALLATION OF FIRE ALARM SYSTEMS Installation

More information

Building and Development

Building and Development Upcoming Events Building and Development Loyalist Township Development Services Department www.loyalist.ca 613-386-7351 Introduction Issue 2 October 2015 Loyalist Township Building Department proudly introduces

More information

Module 9: Ontario Building Code Fire Fighting Provisions

Module 9: Ontario Building Code Fire Fighting Provisions Ontario Building Code (OBC) 1. Sprinklers 2. Standpipes 3. Fire Alarms 4. Entrances Ontario Building Code (OBC) 1. Sprinklers 2. Standpipes 3. Fire Alarms 4. Entrances 1. Sprinklers i) Sprinkler Systems

More information

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS 2013 Randal Brown & Associates Engineering Ltd. 1 RANDAL BROWN & ASSOCIATES ENGINEERING LTD. CONSULTING ENGINEERS LIFE SAFETY & FIRE PROTECTION 105 6 LANSING SQUARE TORONTO, ONTARIO CAN/ULC-S1001-11 INTEGRATED

More information

Short Term Accommodations Fire Code Requirements

Short Term Accommodations Fire Code Requirements Short Term Accommodations Fire Code Requirements 1 Foreward The following is a comprehensive reference to Retrofit 9.3 of Division B of the Ontario Fire Code (OFC). Retrofit provisions were developed to

More information

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning CAN/ULC S1001-11 Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning Presentation To: Canadian Fire Alarm Association (CFAA) National Capital Region

More information

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS HVAC Upgrades Phase 2 Page 1 of 5 Part 1 General 1.1 SUMMARY.1 Section Includes:.1 Materials and installation for fire alarm systems upgrades..2 Audible signal devices..3 End-of-line devices..4 Sustainable

More information

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION Ruling No. 10-20-1256 Application No. B-2010-12 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF with Article Sentences

More information

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. 2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is

More information

BUILDING CODE INTERPRETATION

BUILDING CODE INTERPRETATION BUILDING CODE INTERPRETATION November 2017 14-BCI-009 Page 1 of 6 FIRE ALARM AND FIRE SUPPRESSION SYSTEM VERIFICATION AND TESTING CERTIFICATES PURPOSE This STANDATA has been developed to give municipalities

More information

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Services and Fire Protection Equipment Linda MacKay DATE: November 10, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter Ballot Final Results The

More information

MFES READY Make your home fire safe. Home Smoke Alarms

MFES READY Make your home fire safe. Home Smoke Alarms MFES READY Make your home fire safe Home Smoke Alarms Working smoke alarms keep you and your family safe. It s the law and it could save your life and the lives of your loved ones. Are you READY to Make

More information

OAA Conference ,

OAA Conference , OAA Conference 2013 OUR PROFILE OVERVIEW Amongst the world s leaders in professional services Listed on the Toronto Stock Exchange (GNV) $1.8 bn pro forma 2011 revenues 15,000 +300 35 EVERY CONTINENT EMPLOYEES

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS RANDAL BROWN & ASSOCIATES ENGINEERING LTD. CONSULTING ENGINEERS LIFE SAFETY & FIRE PROTECTION 105 6 LANSING SQUARE TORONTO, ONTARIO CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY

More information

OWNERS RESPONSIBILITIES & CASE STUDIES ONTARIO FIRE CODE. John Percy, Public Education Officer Waterloo Fire Rescue

OWNERS RESPONSIBILITIES & CASE STUDIES ONTARIO FIRE CODE. John Percy, Public Education Officer Waterloo Fire Rescue OWNERS RESPONSIBILITIES & CASE STUDIES ONTARIO FIRE CODE John Percy, Public Education Officer Waterloo Fire Rescue AGENDA: Fire Protection and Prevention Act and Ontario Fire Code Role of Assistants to

More information

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION Ruling No. 03-30-928 Application No. 2003-34 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF Sentence 3.1.8.12.(1)

More information

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Service and Fire Protection Equipment Gregory Harrington, P.E., Staff Liaison DATE: October 1, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter

More information

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES Office of the Fire Marshal and Emergency Management Preface This guideline updates TG-02-1998 published in June 1998. Portions of the guideline

More information

ENERGY EFFICIENCY AFTER DECEMBER 31, 2016

ENERGY EFFICIENCY AFTER DECEMBER 31, 2016 MODULE 2 Energy Efficiency INTRODUCTION In this module the requirements for energy efficiency in buildings is examined with particular attention to the Supplementary Standard to the OBC, SB-10, Energy

More information

Part 3 BUILDING CODE MYTHS & INTERPRETATIONS

Part 3 BUILDING CODE MYTHS & INTERPRETATIONS Part 3 BUILDING CODE MYTHS & INTERPRETATIONS November 18, 2016 Frank Durante, RBO Building Inspector District of Mission Phone 604 820 3729 Wendy Morrison, AScT, BCQ GHL CONSULTANTS LTD Fire Science and

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

CSA B Code Installation Code for Oil-Burning Equipment Yukon Housing Contractor s Breakfast March 2014 Presented by Ron Bramadat, Ken Alaric &

CSA B Code Installation Code for Oil-Burning Equipment Yukon Housing Contractor s Breakfast March 2014 Presented by Ron Bramadat, Ken Alaric & Installation Code for Oil-Burning Equipment Yukon Housing Contractor s Breakfast March 2014 Presented by Ron Bramadat, Ken Alaric & Stan Dueck 1 CHANGES This presentation will addresses some changes to

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved

More information

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS SECTION 610 CARBON MONOXIDE ALARMS 610.1. General. Section 610 covers the application, installation, performance and maintenance of carbon monoxide alarms and carbon monoxide detectors, and their components,

More information

DIVISION C ADMINISTRATIVE PROVISIONS

DIVISION C ADMINISTRATIVE PROVISIONS For what s new, check out www.regulationsandstatutes.com 374 DIVISION C ADMINISTRATIVE PROVISIONS SECTION 1.1 GENERAL Subsection 1.1.1. Chief Fire Official Appointment by Fire Marshal 1.1.1.1. (1) The

More information

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015 CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015 Fire Commissioning in Canadian Codes and Standards BACKGROUND Why Commissioning?

More information

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS The State Uniform Fire Prevention and Building Code (the Uniform Code) includes the publications that are incorporated by reference in Parts 1220 to 1227 of Title 19 of the New York Codes, Rules and Regulations

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-26992-0 SOUTH AFRICAN NATIONAL STANDARD Fire detection and alarm systems for buildings System design, installation and servicing Published by SABS Standards Division 1 Dr Lategan Road Groenkloof

More information

Photovoltaic (Solar) Array Installation Guide

Photovoltaic (Solar) Array Installation Guide Building & Safety Division Community Development Department 7351 Rosanna Street, Gilroy, CA 95020 Phone: 408 846-0451 Fax: 408 846-0429 Visit us: www.cityofgilroy.org Photovoltaic (Solar) Array Installation

More information

BCBC 2012 CHANGES TO PART 3

BCBC 2012 CHANGES TO PART 3 BCBC 2012 CHANGES TO PART 3 Focus on changes that will have an practical effect. Basic concepts reviewed details to be confirmed. Material from Part 3 and related material from Part 9 Generally a harmonization

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

BULLETIN BU/EL Revised August 11, 2015

BULLETIN BU/EL Revised August 11, 2015 BULLETIN 2000-019-BU/EL Revised August 11, 2015 TRANSMITTING UNIT FROM PROTECTED PREMISES TO FIRE SIGNAL RECEIVING CENTRE IN CONFORMANCE WITH CAN/ULC-S561 The intent of this bulletin is to clarify the

More information

SECTION 915 CARBON MONOXIDE DETECTION

SECTION 915 CARBON MONOXIDE DETECTION SECTION 915 CARBON MONOXIDE DETECTION 915.1. General. Carbon monoxide alarms and carbon monoxide detectors shall be installed in buildings as required in accordance with Section 915.2 for residential buildings

More information

(House Bill 849) Public Safety Rental Dwelling Units Carbon Monoxide Alarms

(House Bill 849) Public Safety Rental Dwelling Units Carbon Monoxide Alarms Chapter 175 (House Bill 849) AN ACT concerning Public Safety Rental Dwelling Units Carbon Monoxide Alarms FOR the purpose of altering certain requirements relating to carbon monoxide alarms as the requirements

More information

A Building Manager s Guide to Maintaining Fire Code Compliance

A Building Manager s Guide to Maintaining Fire Code Compliance A Building Manager s Guide to Maintaining Fire Code Compliance Know your role in conducting fire protection system inspections : Fire Alarm Codes and Standards Maintaining your compliance with fire code

More information

Smoke Alarms and Carbon Monoxide Alarms

Smoke Alarms and Carbon Monoxide Alarms 70 N 1st Street Campbell, California 95008 Phone (408) 866-2130 Fax (408) 871-5101 Smoke Alarms and Carbon Monoxide Alarms March, 2018 When building permits are issued for additions, alterations or repairs

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1) July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: This Checklist outlines

More information

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS SECTION 907 FIRE ALARM AND DETECTION SYSTEMS 907.1 General. This section covers the application, installation, performance and maintenance of fire alarm systems and their components in new and existing

More information

Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014

Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014 Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014 Philip Rizcallah, P. Eng. NRC-IRC Canadian Codes Centre Presented by Stan Dueck CRBO Overview Where are the major

More information

VERIFICATION OF FIRE ALARM SYSTEMS

VERIFICATION OF FIRE ALARM SYSTEMS DEVELOPMENT, BUILDINGS AND LICENSING Chief Building Official (CBO) and Building Code and Policy Building Policy Branch The intent of this bulletin is to clarify requirements of verification of the fire

More information

Louis-Philippe Gagnon Alarm System Auditor UNDERWRITTERS LABORATORIES OF CANADA May 13 th, 2015

Louis-Philippe Gagnon Alarm System Auditor UNDERWRITTERS LABORATORIES OF CANADA May 13 th, 2015 Louis-Philippe Gagnon Alarm System Auditor UNDERWRITTERS LABORATORIES OF CANADA May 13 th, 2015 UL and the UL logo are trademarks of UL LLC 2012 GOALS OF INSPECTING AND TESTING POWER SUPPLIES Verify/inspect

More information

Large Family Daycare Guideline

Large Family Daycare Guideline Moreno Valley Fire Department Fire Prevention Bureau Large Family Daycare Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 10, 2017 Large Family Daycare Guideline Purpose

More information

Bold items are particular to the City of Euless

Bold items are particular to the City of Euless EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 8/2004 Fire Chief Lee Koontz Fire Marshal Paul Smith EFD-FMO 3-1 2003 International Fire & Building Code as Amended NFPA Standards

More information

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016 Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting Prepared Especially for : OSFM TEC 2016 Acceptance Testing 11-2008 Agenda Before you begin Completing the

More information

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain CAN/ULC-S561 To comply, or not to comply. actually it s not even a question! By Alan Cavers & Brian McBain CAN/ULC-S561, Installation And Services For Fire Signal Receiving Centres And Systems is without

More information

Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing

Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing Ted Ross Labour & Advanced Education Gerard Donahoe Labour & Advanced Education Overview Where

More information

CERTIFICATION BULLETIN

CERTIFICATION BULLETIN File: ULC-S527-11 ULC-G5.2 June 1, 2012 CERTIFICATION BULLETIN 2012-04 Effective Date Announcement CAN/ULC-S527-11, 3 rd Edition of the Standard for Control Unit for Fire Alarm Systems To: Subscribers

More information

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE: RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE: Manitoba Regulation 221/2015 and Manitoba Regulation 222/2015 DATE: MARCH 17, 2016 1. INTRODUCTION On April 1, 2016, new building and

More information

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions. 11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency

More information

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL Page 2 of 16 EXPLANATORY MATERIAL In November 1996, the Fire Technical Council introduced a guideline entitled "Approved Fire Safety Guidelines for Apartment Buildings". The guideline was established under

More information

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act Providing standards for carbon monoxide alarms; and imposing penalties. The General Assembly of the

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

TrueAlert Notification Appliances

TrueAlert Notification Appliances TrueAlert Notification Appliances UL Listed; FM, CSFM and MEA (NYC) Approved* Non-Addressable Audible/Visible Notification Appliances with SmartSync Operation of Strobes and Horns Features Wall mount audible/visible

More information

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012 SAFETY CODES COUNCIL #1000, 10665 Jasper Avenue N.W., Edmonton, Alberta, Canada, T5J 389 Tel: 780-413-0099 I 1-888-413-0099 Fax: 780-424-5134 I 1-888-424-5134 www.safetycodes.ab.ca COUNCIL ORDER No. 0015423

More information

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES. 1 of 7 11/12/ :26 PM

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES. 1 of 7 11/12/ :26 PM 1 of 7 11/12/2009 10:26 PM Skip Navigation Central Site Contact Us Site Map Français OFM HOME ABOUT THE OFM FIRE SERVICE FIRE PROTECTION FIRE SAFETY & PUBLIC EDUCATION LEGISLATION PUBLICATIONS RESOURCES

More information

FEO Initiation Devices Dean McLellan

FEO Initiation Devices Dean McLellan FEO Initiation Devices Dean McLellan Enforcement Protocol 1. TSSAct 2. Ontario Regulation 209/01 3. Code Adoption Document (CAD) 4. Director s Orders 5. Applicable Code 1. Sub Codes (NBCC, CEC) A17/B44

More information

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION CHAPTER 23.45 Sections LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION 23.45.100 Local amendments to the International Fire Code, 2006 Edition... 2 23.45.102.1 Construction and design provisions...

More information

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 28 3111 DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Manual fire-alarm boxes. 3. System smoke detectors. 4. Heat detectors.

More information

COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE

COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE 100130 Description The first part of the course presents the requirements for fire alarm systems. It describes the buildings

More information

For additional information regarding R-3.1 residential care facilities please contact (951)

For additional information regarding R-3.1 residential care facilities please contact (951) Riverside County Fire Department Fire/Life Safety Inspection Division Riverside Office: 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4823 Fax (951) 955-4886 Palm Desert Office: 77-933 Las

More information

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS 1) Purpose: In an effort to provide for consistency in administering the Existing Building Code and Property Maintenance Code for existing buildings as they pertain to Certificates of Use and Occupancy,

More information

Residential Based Care Facility Guidelines

Residential Based Care Facility Guidelines Moreno Valley Fire Department Fire Prevention Bureau Residential Based Care Facility Guidelines Approved and Authorized By: Randall Metz, Fire Marshal Issued: January 1, 2011 Residential Based Care Facilities

More information

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course Florida Building Code 2010 Chapter 9 Fire Protection Systems Advanced Course 1 Introduction This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Alarm System Plan Review 2009 International Fire Code and 2010 NFPA 72 Date of Review // BLD201 - Project Address: Project Name: _ Professional

More information

Variance from Chapter 297, Signs, of the Former City of Toronto Municipal Code Bloor Street West (High Park)

Variance from Chapter 297, Signs, of the Former City of Toronto Municipal Code Bloor Street West (High Park) Variance from Chapter 297, Signs, of the Former City of Toronto Municipal Code - 2595 Bloor Street West (High Park) (City Council on August 1, 2, 3 and 4, 2000, adopted this Clause, without amendment.)

More information

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS HOMES BUILT PRIOR TO JANUARY 1, 1975 WITH NO RENOVATIONS As of December 1, 2016, upon sale or transfer Must be located on every level of the residence Must be located on the ceiling at the base of each

More information

2018 NICET Code Transition Changes

2018 NICET Code Transition Changes 2018 NICET Code Transition Changes NICET will be transitioning to newer codes accepted in their exams in mid-october 2018, specifically: NFPA 72 2016 NFPA 70 2014 IBC 2015 NFPA 101 2015 Here are some changes

More information

Building Name: Our Lady of Sorrows Date: July 10, 2013

Building Name: Our Lady of Sorrows Date: July 10, 2013 1 E1. FIRE ALARM SYSTEM ANNUAL TEST AND INSPECTION REPORT (Reference: 5.1.2) Building Name: Our Lady of Sorrows Date: July 10, 2013 Address 19 Mohns Avenue Petawawa, ON System Manufacturer: Siemens Model

More information

Red Deer. AMA Regional Meeting. Electrical, Plumbing, Gas, Private Sewage, Building and Fire

Red Deer. AMA Regional Meeting. Electrical, Plumbing, Gas, Private Sewage, Building and Fire Red Deer AMA Regional Meeting Electrical, Plumbing, Gas, Private Sewage, Building and Fire AGENDA 8:30 am Call to Order and Introductions Mike Hill, AMA 8:35 am 8:45 am AMA General Updates Joe Healy, AMA

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 13852- PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this

More information

Florida Building Code 2010

Florida Building Code 2010 Introduction Florida Building Code 2010 Chapter 9 Fire Protection Systems This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors are familiar with

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual for Model 2100 Fire+Smoke systems from Smoke Guard, Inc. 287 N. Maple Grove - Boise, ID 83704 Phone: (800) 574-0330 Fax: (208) 639-7851 E-Mail: info@smokeguard.com Website:

More information

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD PART 1 - GENERAL PURPOSE This Standard is intended to assure that fire detection/alarm systems at The University of Texas at Austin provide the highest level of fire safety possible. SCOPE This standard

More information

BOMA Calgary Luncheon Thursday, October 11, 2012 Building Owners Responsibilities for Fire Safety Equipment (Fire Alarm) Canadian Fire Alarm

BOMA Calgary Luncheon Thursday, October 11, 2012 Building Owners Responsibilities for Fire Safety Equipment (Fire Alarm) Canadian Fire Alarm 1 BOMA Calgary Luncheon Thursday, October 11, 2012 Building Owners Responsibilities for Fire Safety Equipment (Fire Alarm) Canadian Fire Alarm Association 2 Presentation Overview The Codes Your responsibilities

More information

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to

More information

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only) 2007 & CFC Residential Care Facility Requirements (24 hour care only) Occupancy Construction Smoke Barrier I-1 Bedridden 7+non- Ambs Or bed- Ridden R-4 7+ambs (May have 6 nonambs or 6 bedridden) R-3.1

More information