PROFESSIONAL SUPPLIER

Size: px
Start display at page:

Download "PROFESSIONAL SUPPLIER"

Transcription

1 PROFESSIONAL SUPPLIER FOR FIRE-FIGHTING EQUIPMENT IRON MAN INDUSTRY LIMITED

2 Sprinkler Small orifice, standard and quick response, spray sprinkler Designed for use in light hazard occupancies Requires less water than standard K=5.6 orifice sprinkler Pintle provides visual indication that these sprinkler have an orifice other than k=5.6 Model Temperature Glass Bulb Thread Max.Service K Factor Glass Bulb Rating Color Size Pressure Diameter SSP-SR /68 Red 175 /79 Yellow 200 /93 Green NPT1/2 or R1/2 175psi (1.2MPa) 5.6 (80) 5mm Model Temperature Glass Bulb Thread Max.Service K Factor Glass Bulb Rating Color Size Pressure Diameter SSP-SR /68 Red 175 /79 Yellow 200 /93 Green NPT1/2 or R1/2 175psi (1.2MPa) 5.6 (80) 5mm Model Temperature Glass Bulb Thread Max.Service K Factor Glass Bulb Rating Color Size Pressure Diameter SSP-SR /68 Red 175 /79 Yellow 200 /93 Green NPT1/2 or R1/2 175psi (1.2MPa) 5.6 (80) 5mm Model Temperature Glass Bulb Thread Max.Service K Factor Glass Bulb Rating Color Size Pressure Diameter SSP-SR /68 Red 175 /79 Yellow 200 /93 Green NPT1/2 or R1/2 175psi (1.2MPa) 5.6 (80) 5mm Model Temperature Glass Bulb Thread Max.Service K Factor Glass Bulb Rating Color Size Pressure Diameter SSP-SR /68 Red 175 /79 Yellow 200 /93 Green NPT1/2 or R1/2 175psi (1.2MPa) 5.6 (80) 5mm Model Temperature Glass Bulb Thread Max.Service K Factor Glass Bulb Rating Color Size Pressure Diameter SSP-SR /68 Red 175 /79 Yellow 200 /93 Green NPT1/2 or R1/2 175psi (1.2MPa) 5.6 (80) 5mm

3 Sprinkler Hose BRAIDED FLEXIBLE HOSE Model # Length(mm) EFB2(3) EFB2(3) EFB2(3) EFB2(3) EFB2(3) UNBRAIDED FLEXIBLE HOSE Model # Length(mm) EFU2(3) EFU2(3) EFU2(3) EFU2(3) EFU2(3) BRAIDED FLEXIBLE HOSE Model # Length(mm) EFSPC EFSPC EFSPC EFSPC BRAIDED FLEXIBLE HOSE Model # Length(mm) EFDC EFDC EFDC EFDC

4 Sprinkler Hose Accessary For Fixing Model: SSB 01 Snap Clamp Center Bracket for Stock Bar Model: SSB 02 Snap Clamp Center Bracket for Stock Bar Model: SBB 01 Center Bracket for Stock Bar Model: SBB 02 Center Bracket for Stock Bar Model: OSSB 01 Open Gate Snap Center Bracket for Stock Bar Model: SSBR 01 Open Gate Snap Center Bracket for Ceiling Anchor Model: OMSB 01 Open Gate Center Bracket for Stock Bar

5 Wet Alarm Check Valve GENERAL DESCRIPTION Model ZSFZ Alarm Check Valves are divided seat ring, rubber faced clapper, check type water-flow alarm valves which are intended for use in wet pipe (automatic sprinkler) fire protection systems. They are designed to automatically actuate electrically and/or hydraulically operated alarms when there is a steady flow of water into the system which is equivalent to the discharge rate of one or more sprinklers. Type Standards Working Pressure(MPa) Materials Interface Form Outside Size(mm) Certification ZSFZ DN Flange 560*410*470 FM Nodular ZSFZ DN Flange 620*410*470 FM cast iron ZSFZ DN Flange 640*450*480 FM 4 inch (100mm) 6 inch (150mm) 8 inch (200mm) Nominal Dimensions in Inches and (MM) ANSI B16.1 (CLASS 150) ISO 2084 (PN16) A B C A B C (190.5) (19.1) (180.0) (18.0) (241.3) (22.2) (240.0) (22.0) (298.5) (22.2) (295.0) (22.0) 8

6 Lever Deluge Alarm Valve GENERAL DESCRIPTION Model ZSFG/FM External Resetting Deluge Valves are differential latch type valves designed for fire protection system service. They are used as automatic water control valves in deluge, pre-action, and special types of fire protection systems such as foam water and double interlock. The ZSFG/FM Valves also provide for actuation of fire alarms upon system operation. Type Standards Working Materials Interface Outside Size(mm) Certification Pressure(MPa) Form ZSFG DN Nodular Flange 612*488*561 FM ZSFG DN cast iron Flange 630*540*572 FM Nominal Dimensions in Inches and (MM) 4" (100 mm) Valve Size 6" (150 mm) Valve Size A B A B ANSI B16.1 (CLASS 150) 7.50 (190.5) 0.75 (19.1) ISO 2084 (PN16) 7.09 (180.0) 0.71 (18.0)

7 Water Motor Gong GENERAL DESCRIPTION The ZSJL water motor gong discussed in this Report is a device which sounds a locally audible alarm when a fire protection system operates, usually when an alarm valve trips. The flow from the alarm valve pressure port is piped to the inlet of the water motor gong housing, which induces the impeller to spin the drive shaft and rotate the striker assembly. The rotating striker impacts the inside of the shell, thereby producing the audible alarm. Type: Model ZSJL Water Motor Alarm Hydraulically Operated Mechanical Sprinkler Alarm Working Water Pressure Range: 1.2Mpa Nozzle K-Factor: 0.7GPM/PSI 1/2(10,1 LPM/bar1/2) Y-Strainer: 3/4 inch, cast iron, 20 mesh screen Trim Components: Galvanized steel nipples and cast iron fittings

8 Fire Hose Light weight; construction tightness Corrosion resistance; ageing resistance Weather resistance; Mildew resistance UV resistance and long serving life Size(mm) Working Pressure(MPa) Bursting Pressure(MPa) General Description Single jacket. Polyester warp and filler. EPDM rubber lined. Available with service test pressure of 150PSI and 250PSI Application Fire-fighting; Shipping; petroleum; Chemical industry; Agriculture; Mining Color White; yellow; red; or as per customer s instruction Standard Length 10M up to 40M EPDM Rubber Liner Hot Melt/Rubber Backing Adhesive Polyester Jacket Properties to use Hot Melt: Light weight, good adhesive strength Properties to use Rubber backing adhesive: more flexible and has higher heat resistance other hoses using other adhesive

9 Fire Hose Reel Model Type Specification CSJR-01-A Manual 25mm*30m Swinging CSJR-01-B Manual Swinging 33mm*20m 33mm*30m Model Type Specification CSJR-02-A Manual 19mm*30m Fixed CSJR-02-B Manual Fixed 25mm*30m Model Type Specification CSJR-06-A Automatic Swinging 19mm*20m 19mm*30m CSJR-06-B Automatic Swinging 25mm*25m 25mm*30m Model Type Specification CSJR-07-A Manual 19mm*30m Swinging CSJR-07-B Manual Swinging 25mm*25m 25mm*30m

10 Fire Hose Reel Model Type Specification CSJR-08-A Manual Swinging 19mm*20m 19mm*30m CSJR-08-B Manual Swinging 19mm*36m Model Type Specification CSJR-10-A Automatic Swinging 25mm*20m 25mm*30m CSJR-10-B Automatic Swinging 19mm*45m Model Type Specification CSJR-12-A Manual, Swinging pipe 19mm*30m Model Type Specification CSJR-13-A Automatic, Swinging pipe 19mm*30m

11 Fire Hose Reel Model Type Specification CSJR-14-A Manual, Swinging pipe 25mm*30m Model Type Specification CSJR-15-A Automatic, Swinging pipe 25mm*30m

12 Fire Hose Reel Cabinet

13 Fire Hose Reel Cabinet

14 Fire Hose Reel Cabinet Landing Valve Cabinet

15 Indicator Post

16 Flanged-End Gate Valve

17 Grooved-End Gate Valve

18 Flanged X Grooved-End Gate Valve

19 Grooved-End Gate Valve

20 Flanged X Grooved-End Gate Valve

21 Flanged-End Gate Valve

22 Grooved-End Butterfly Valve

23 Grooved-End Swing Check Valve

24 Dry Barrel Hydrants

25 Grooved Fitting Rigid Coupling Flexible Coupling 1" up to 16" 1" up to 16" Sloping Coupling Shouldered Coupling 1" up to 8" 4" up to 6" Mining Coupling 4" Reducing Flexible Coupling 2"*1" up to 8"*6" Grooved Equal Tee Grooved Reducing Tee 1" up to 12" 2"*1" up to 12"*10" Threaded Reducing Tee Grooved Mechanical Tee 1 1/2"*1" up to 10"*3" 2" * 1 1/4" up to 10" * 4"

26 Grooved Fitting Threaded Mechanical Tee 1 1/2"*1" up to 8"*4" Cross 1 1/4" up to 8" Grooved Reducing Cross 3"*2 1/2" up to 6"*4" 90 Grooved Elbow 1" up to 12" Grooved Elbow 22.5 Grooved Elbow 4" up to 10" 3" up to 8" 45 Grooved Elbow 1" up to 12" Grooved Concentric Reducer 1 1/4"*1" up to 12"*10" Threaded Concentric Reducer Grooved Eccentric Reducer 1 1/4"*1" up to 8"*3" 4"*2 1/2" up to 8" * 6"

27 Grooved Fitting 1.6 MPa Flange Adaptor Grooved 2.5 MPa Flange Adaptor Grooved 2" up to 12" 4" up to 6" 1.0 MPa Flange Adaptor Grooved 2" up to 8" Grooved Split Flange 2" up to 8" General Flange Cap 4" up to 6" 1" up to 12" Threaded Eccentric Cap U-Bolted Mechanical Tee Threaded 2"*1 1/2" up to 8"*2" 1"*1/2" up to 2 1/2"*1" Grooved Mechanical Cross Threaded Mechanical Cross 2"*1 1/4" up to 8"*4" 2"*3/4" up to 8"*4"

28 Breeching Inlet

29 Landing Valve

30 Landing Valve

31 Landing Valve

32 Swivel Hanger

33 Beam Clamp

34 Clevis Hanger

35 Cup Nut Pipe Loop

36 Fire Blanket Product name: Fire blanket Model: CS06 Standard: BS EN m*1.1m 1.2m*1.2m 1.2m*1.8m Product Description: Fiberglass fire blanket as a small-sized civil fire blanket is widely used for kitchens, supermarkets, cinemas and oil stations and has advantages of convenient carrying and operation. Specification: CS06 Material: Fiberglass Coat: Silicon Gross weight: /m 2 Thickness: mm Temperature Resistance: Packaging: PVC Box PVC Bag, Polyester bag; PP box Certificate: BS EN1869:1997; Outer Packing: Sturdy and durable carton for export, pallet

37 Fire Blanket Product name: Fire blanket Model: CS09 Standard: TUV EN m*1.0m 1.2m*1.8m 1.2m*1.2m 1.8m*1.8m Product Description: Fiberglass fire blanket as a small-sized civil fire blanket is widely used for kitchens, supermarkets, cinemas and oil stations and has advantages of convenient carrying and operation. Specification: CS09 Material: Fiberglass Coat: Silicon Gross weight: /m 2 Thickness: mm Temperature Resistance: Packaging: PVC Box PVC Bag, Polyester bag; PP box Certificate: TUV EN1869:1997; Outer Packing: Sturdy and durable carton for export, pallet

38 Fire Blanket Product name: Fire blanket Model: CW380 Standard: AS/NZS M*0.9M 1.2M*1.2M 1.0M*1.0M 1.1M*1.1M 1.2M*1.8M 1.8M*1.8M Product Description: Fiberglass fire blanket as a small-sized civil fire blanket is widely used for kitchens, supermarkets, cinemas and oil stations and has advantages of convenient carrying and operation. Specification: CW380 Material: Fiberglass Coat: No Gross weight: /m 2 Thickness: mm Temperature Resistance: Packaging: PVC Box PVC Bag, Polyester bag; PP box Certificate: AS/NZS 3504 Outer Packing: Sturdy and durable carton for export, pallet

39 Fire Blanket Product name: Fire blanket Model: CWT380 Standard: TUV EN m*1.0m 1.2m*1.8m 1.2m*1.2m 1.8m*1.8m Product Description: Fiberglass fire blanket as a small-sized civil fire blanket is widely used for kitchens, supermarkets, cinemas and oil stations and has advantages of convenient carrying and operation. Specification: CWT380 Material: Fiberglass Coat: Silicon Gross weight: /m 2 Thickness: mm Temperature Resistance: Packaging: PVC Box PVC Bag, Polyester bag; PP box Certificate: TUV EN1869:1997; Outer Packing: Sturdy and durable carton for export, pallet

40 ABC Dry Powder Fire Extinguisher Stored Pressure Description: Used on most types of fires including solid combustibles known as Class A fire, flammable liquids known as Class B fires and flammable gases known as Class C fires as well as electrical fires. Extinguisher Type 1 Kg Powder 2 Kg Powder 4 Kg Powder 6 Kg Powder 6 Kg Powder 9 Kg Powder Model No. PDB10 PDB20 PDB40 PDB60 PRB60 PDB90 Capacity 1Kg 2Kg 4Kg 6Kg 6Kg 9Kg Fire Rating 8A/55B/C 13A/89B/C 27A/183B/C 43A/233B/C 43A/233B/C 55A/233B/C Cylinder Structure Deep-drawn Deep-drawn Deep-drawn Deep-drawn Rolling-welded Deep-drawn Operating Pressure 14 Bar 14 Bar 14 Bar 14 Bar 14 Bar 14 Bar Discharge Time 8 s 10 s 17 s 17 s 17 s 22 s Temperature Range -30 to to to to to to +60

41 AFFF Foam Extinguisher Stainless Steel Description: Ideal for multi-risk situations where class A and B fires that typically involve liquids or materials that liquefy such as petrol, oils, paints and fats. Foam fire extinguish should not be used on live electrical equipment. All models have a spray nozzle which produces a very effective spread of foam, even when used by an inexperienced operator. This foam fire extinguisher are perfect for use in prestigious office environments as they are supplied complete with bracket and can quickly and easily be wall mounted or placed on a fire extinguisher floor stand. Extinguisher Type 6L Foam Model No. SFRA6060 Capacity 6L Fire Rating 27A/183B Cylinder Structure Rolling-welded Operating Pressure 12 Bar Discharge Time 22 s Temperature Range +5 to +60

42 AFFF Foam Extinguisher Stainless Steel Description: Ideal for multi-risk situations where class A and B fires that typically involve liquids or materials that liquefy such as petrol, oils, paints and fats. Foam fire extinguish should not be used on live electrical equipment. All models have a spray nozzle which produces a very effective spread of foam, even when used by an inexperienced operator. This foam fire extinguisher are perfect for use in prestigious office environments as they are supplied complete with bracket and can quickly and easily be wall mounted or placed on a fire extinguisher floor stand. Extinguisher Type 6L Foam Model No. SFRA6060 Capacity 6L Fire Rating 27A/183B Cylinder Structure Rolling-welded Operating Pressure 12 Bar Discharge Time 22 s Temperature Range +5 to +60

43 CO2 Extinguisher Description: Protection against Class B fires, which are fires that involve flammable liquids such as petrol, oils, and solvents. CO2 fire extinguisher are also suitable for use on live electrical equipment and can be used to protect electrical equipment such as computers and servers.co2 extinguisher do not leave a residue and are ideal for use in offices. Extinguisher Type 2Kg CO2 5Kg CO2 Model No. CA20 CA50 Capacity 2 Kg 5 Kg Fire Rating 34B 89B Cylinder Structure Alloy Alloy Operating Pressure 170 Bar 170 Bar Discharge Time 10 s 15 s Temperature Range -20 to to +60

44 Extinguisher Cartridge Description: Ideal for high-hazard areas where fast, effective fire protection is needed such as mining, utilities, forestry, transportation, petroleum and heavy industry. All units use carton dioxide as the expellant gas..available in 6KG,9KG powder and 6L,9L foam. Extinguisher Type 6 Kg Powder 9 Kg Powder Model No. GPDA60 GPDA90 Capacity 6 Kg 9 Kg Fire Rating 55A/233B/C 55A/233B/C Cylinder Structure Deep-drawn Deep-drawn Operating Pressure 14 Bar 14 Bar Discharge Time 17 s 22 s Temperature Range -30 to to +60

45 Water Fire Extinguisher Description: Protection against Class A fires that typically involve common combustible materials such as wood,paper,strew,textiles,soft furnishing and materials. Remember not to use water fire extinguisher on fires that involve live electrical equipment. Our tried and tested 9L water fire extinguisher is filled only with pure water and is therefore safe for the environment. They are suitable for use in a wide range of environments including offices, factored and warehouses. Extinguisher Type 9L Water Model No. WDA90 Capacity 9L Fire Rating 21A Cylinder Structure Deep-drawn Operating Pressure 12 Bar Discharge Time 65 s Temperature Range +5 to +60

46 Wheeled Fire Extinguisher Foam Description: The perfect fire protection equipment for use on sites, warehouses and in larger industrial sites Wheeled fire extinguisher are study and robust. Our wheeled fire extinguisher trolley units are manufactured from robust materials and are on wheels to make them easy to move Extinguisher Type 25 L Foam 50 L Foam Model No. TFA250 TFA500 Capacity 25 L 50 L Fire Rating 34A-IIIB-C 34A-IIIB-C Cylinder Structure Rolling-welded Rolling-welded Operating Pressure 12 Bar 12 Bar Discharge Time 60 s 60 s Temperature Range +5 to to +60

47 Wheeled Fire Extinguisher Powder Description: The perfect fire protection equipment for use on sites, warehouses and in larger industrial sites Wheeled fire extinguisher are study and robust. Our wheeled fire extinguisher trolley units are manufactured from robust materials and are on wheels to make them easy to move Extinguisher Type 25 Kg Powder 50 Kg Powder Model No. TPB250 TPB500 Capacity 25 Kg 50 Kg Fire Rating 55A-IIIB-C 55A-IIIB-C Cylinder Structure Rolling-welded Rolling-welded Operating Pressure 14 Bar 14 Bar Discharge Time 50 s 50 s Temperature Range -30 to to +60

48 Fireman Suit Description Outer shell: NOMEXIIIA Moisture barrier: aramid spuniace substrate with PTFE membrane Thermal lining: aramid felt Comfortable layer:aramid/viscose woven fabric Color: Black,Navy blue, Read, Orange, Yellow Standard: EN 469:2005+A1:2006

49 Stand-Alone Smoke Detector Main Features Photoelectric sensing technology Easy installation and maintenance Sleek low-profile housing design Low-battery warning Test button verifies battery and alarm operation Specification: Smoke Sensitivity: db/m to 0.14 db/m Power Supply: 9V Battery Life: >12months Low battery life: >30days Alarm indicator: continuously red light and sounder Alarm sound level: >85dB at 10 feet(3m) Temperature: 0-50 Humidity: 10% - 90%RH, no condensation or icing Dimensions: DT-S01/DT-S02: 107*35mm DT-S03: 130*40mm

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE Capacity: 1,, 5, 10 Kgs UFS dry powder type extinguishers are designed for protection of light and ordinary hazards. Suitable for A, B,

More information

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,

More information

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup

More information

Extinguishers. Commercial Industrial High rise buildings

Extinguishers. Commercial Industrial High rise buildings Commercial Industrial High rise buildings Extinguishers Design, Supply, Installation, Testing, Commissioning, Maintenance, and Service of Firefighting and Fire Protection Systems Think fire protection......thank

More information

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry

More information

HRS035-MS-022-RD 22 (559mm) 19mm x 30m 310mm Fixed Manual. HRS037-GI-019-RD 19 (483mm) 19mm x 36m 350mm Swing Manual

HRS035-MS-022-RD 22 (559mm) 19mm x 30m 310mm Fixed Manual. HRS037-GI-019-RD 19 (483mm) 19mm x 36m 350mm Swing Manual FIRE HOSE REEL CertIFIeD to Bs en 671-1: 1995 Certification No: Ps005704 BRITISH STANDARDS INSTITUTION APPROVAL FIRE HOSE REELS CERTIFIED TO BS EN 671 LICENCE NO. KM 51857 Certified Product AUSTRALIAN

More information

Design and Supply of Fire Equipments. External Fire Fighting Systems.

Design and Supply of Fire Equipments. External Fire Fighting Systems. Design and Supply of Fire Equipments External Fire Fighting Systems INTRODUCTION Sheyas fire Services is one of the progressive firms in the field of Fire Fighting Equipment s and Consulting Services,

More information

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U ) TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG0176866-U ) FIRE PROTECTION EQUIPMENTS PARTS CATALOGUE TRIMAX ASIA ENGINEERING & CONSTRUCTION No. 24, Jalan Pantai, 12000 Butterworth, Penang, Malaysia. Fax: +6

More information

TOTALPAC2 Integrated Fire Protection System

TOTALPAC2 Integrated Fire Protection System TOTALPAC2 Integrated Fire Protection System Page 1 of 8 General 1. Applicable Standards The TOTALPAC2 Surefire complies with the following standards: - NFPA-13 Sprinkler Systems; - NFPA-15 Water Spray

More information

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description Worldwide Contacts www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry Type Pendent Sprinklers (TY7229)

More information

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE Page 1 of 12 1. (Refer to Figures 1-7.) Viking supervised Single-Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system piping

More information

TotalPac 3 Firecyle III Deluge Remote controlled system

TotalPac 3 Firecyle III Deluge Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical

More information

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers FIRE EXTINGUISHER Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley U.A.E K.S.A www.nteico.com FIRE EXTINGUISHER Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers INDEX NTEICO

More information

PRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E

PRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E - 1 - PRESTO DRY POWDER EXTINGUISHERS - AB:E Certified & Approved to AS/NZS 1841.5 Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments

More information

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Bulletin 060 Rev. A Bulletin 060 Rev. A Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon

More information

In the year 1988, Amit Industrial Corporation is a reputed name in the industry for Manufacturing and

In the year 1988, Amit Industrial Corporation is a reputed name in the industry for Manufacturing and +91-8042973396 Amit Industrial Corporation https://www.indiamart.com/amitindustrialcorporation/ In the year 1988, Amit Industrial Corporation is a reputed name in the industry for Manufacturing and Supplying

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE January 27, 2012 311a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system.

More information

OUT CARBON DIOXIDE (CO2) EXTINGUISHER Certified & Approved to AS/NZS Lightweight Aluminium Cylinder. AS High pressure hose assembly with

OUT CARBON DIOXIDE (CO2) EXTINGUISHER Certified & Approved to AS/NZS Lightweight Aluminium Cylinder. AS High pressure hose assembly with OUT DRY POWDER EXTINGUISHERS - AB:E Certified & Approved to AS/NZS 1841.5 Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments together

More information

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER PAGE: ISSUE: DATE: of A 00 07285 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER MODELS: R2WC 0 07285 ISSUE A FIRST RELEASE NEW DOCUMENT WJJ LRL LHG REV DATE REVISION DESCRIPTION

More information

SPRINKLERS TABLE OF CONTENTS

SPRINKLERS TABLE OF CONTENTS SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Model vkfd28b braided flexible sprinkler drops (lpcb approved) Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM

More information

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

A. Section includes wet-pipe sprinkler system, system design, installation, and certification. SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes wet-pipe sprinkler system, system design, installation, and certification. 1.2 REFERENCES A. General: Comply

More information

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS SECTION 21 1300 S PART 1 -GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

FIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS

FIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS - 1 - WORLD DRY POWDER ABE EXTINGUISHERS Certified & Approved to AS/NZS 1841.5 Fireworld Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments

More information

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. Page 1 of 9 1. (Refer to Figures 1-3.) Viking Electric/Pneumatic Double Interlocked Preaction Systems utilize a Viking deluge valve controlled by a pneumatic actuator (E.1), normally held closed by supervisory

More information

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI FIRE PROTECTION 1 G.I.PIPES Supplying, installing, testing and commissioning of G.I Pipes confirming to IS 3589 Pt - I Heavy grade with painting, suitable type of supports, anchor fasteners, bolts nuts

More information

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco. TN-25 Tunnel Fire Protection System Safer. Smarter. Tyco. Expert Fire Protection for Tunnels Tyco provides a complete fire protection solution to protect the infrastructure of tunnels. Whether it is rail,

More information

Technical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS

Technical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS PAGE: ISSUE: DATE: of 2 A 00 07/22/5 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS MODELS: R3.5CO2 0 07/22/5 FIRST ISSUE A WJJ LRL LHG REV DATE REVISION DESCRIPTION BY CHK APP COVER PAGE/REVISION

More information

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4-20 x 1 THERMAL CUT-OUT THERMAL TRIP PLUG VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" 700300-013 2. THERMAL CUT-OUT 409560-001 THERMAL TRIP PLUG 409210-010 3. HEATER TERMINAL COVER VM99 2-4 HEATER TERMINAL

More information

TECHNICAL DATA. 319a. January 27, 2012

TECHNICAL DATA. 319a. January 27, 2012 January 27, 2012 319a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking Electric/Pneumatic Double Interlocked Preaction Systems utilize a Viking deluge valve controlled by a pneumatic actuator (E.1), normally

More information

TotalPac X Single interlock SUREFIRE system

TotalPac X Single interlock SUREFIRE system DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a trim totally preassembled, pre-wired and factory tested. All electrical and mechanical components of

More information

TECHNICAL DATA. Wet 26a. February 22, 2009

TECHNICAL DATA. Wet 26a. February 22, 2009 February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description Worldwide Contacts www.tyco-fire.com Model ESFR-17 16.8 K-factor Dry Type Pendent s Early Suppression, Fast Response General Description TYCO Model ESFR-17 Dry Type Pendent s are Early Suppression, Fast

More information

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2. PAGE: ISSUE: DATE: of A 00 0745 DOCUMENT TITLE 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.0ABE O 0745 ISSUED FOR USE AS ISSUE A WJJ LRL LHG REV DATE REVISION DESCRIPTION

More information

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description Worldwide Contacts www.tyco-fire.com Model ESFR-17 16.8 K-factor Dry Type Pendent s Early Suppression, Fast Response General Description TYCO Model ESFR-17 Dry Type Pendent s are Early Suppression, Fast

More information

esfr dry pendent sprinkler Vk502 (k14.0)

esfr dry pendent sprinkler Vk502 (k14.0) Page 1 of 11 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing

More information

FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator FIRE EXTINGUISHERS Chapter 2 - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator CO2 FIRE EXTINGUISHER - Dielectric test at 35000 V at 1mtr distance.

More information

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed. Page 1 of 10 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK504 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing

More information

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the

More information

TotalPac X Firecycle III Preaction Double interlock system

TotalPac X Firecycle III Preaction Double interlock system DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a multicycling Firecycle III system trim totally pre-assembled, pre-wired and factory tested. All electrical

More information

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary

More information

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University. 15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.

More information

ADDITIONAL PRODUCTS 65

ADDITIONAL PRODUCTS 65 ADDITIONAL PRODUCTS 65 ADDITIONAL PRODUCTS Pictorial Table of Contents Model FastFlex Flexible Sprinkler Hose Page 67 Sprinkler & Valves Product Overview Page 72 Model UFBX Flexible Hoses Pages 68-69 Figure

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

Deluge & Preac tion Systems

Deluge & Preac tion Systems Deluge & Preaction Systems Deluge Systems are normally used in special hazard installations where water must be applied to an entire area for protection. They use open sprinklers or spray nozzles attached

More information

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL

More information

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler UL Quick Response FM Standard Response ½ (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Solid or perforated cover plate available in chrome and white as Standard

More information

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE Page 1 of 12 1. DESCRIPTION (Refer to Figures 1-6.) Viking Electric/Pneu-Lectric Double Interlocked Preaction Systems utilize a Viking deluge valve, pneumatic supervision of the automatic sprinkler system,

More information

SECTION AUTOMATIC SPRINKLER PIPING

SECTION AUTOMATIC SPRINKLER PIPING SECTION 15330 AUTOMATIC SPRINKLER PIPING ****** ***** **** *** ** * ** *** **** ***** ****** NOTE TO SPECIFIER: This section contains several types of automatic sprinkler piping. Some piping is allowed

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

+91-8048763768 Cease Fire & Electrical Services http://www.ceasefireengineers.com/ We are the supplier, trader and service provider of fire alarm equipment, fire suppression system, fire detection system,

More information

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS ANSUL Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50-B, 450/100-B, 900/100-B INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA SPRINKLER ALARM TECHNICAL DATA MODEL MOUNTING TYPE WATER WORKING PRESSURE CONNECTION GA Type-A & Type-B 17.5 Bar (250 PSI) Inlet : 3/4 BSPT (3/4 NPT) Drain : 1 BSPT (1 NPT) GONG DIAMETER 205mm (8 ) GONG

More information

Twin-Agent Fire Fighting/Securing Systems Specifications

Twin-Agent Fire Fighting/Securing Systems Specifications Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete automatic fire suppression system for the exhaust hood, including necessary accessories.

More information

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent

More information

Model DDX Deluge Valve

Model DDX Deluge Valve Model DDX Deluge Valve Bulletin 510 Bulletin 510 Features 1. Differential type, simple, lightweight, dependable construction. 2. Simply and easily trimmed for releasing by: Manual pull stations Wet pilot

More information

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260 SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat

More information

SECTION SPRINKLER SYSTEMS

SECTION SPRINKLER SYSTEMS SECTION 13900 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following: SECTION 21 10 00 - WATER-BASED FIRE-SUPPRESSION PART I - GENERAL 1.1 SUMMARY A. Inclusion of sprinkler and standpipe systems shall be as determined by NFPA National Fire Code pamphlet 101 and program statement.

More information

B. Related Sections: The following Sections contain requirements that relate to this Section.

B. Related Sections: The following Sections contain requirements that relate to this Section. SECTION 211313- FIRE-SUPPRESSION PIPING PART1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Fire Hose Reel & Cabinets. Company Profile. 26 Techno Fire & Safety Co. LLC

Fire Hose Reel & Cabinets. Company Profile. 26 Techno Fire & Safety Co. LLC No. KM 645625 This is to certify that: Holds Certificate Number: KM 645625 In respect of: BS EN 671 Hose Reels with Semi Rigid Hose SUZHOU HLC PLASTICS INDUSTRY CO.,LTD. XIANGCHENG DISTRICT NO.103,FENGBEIDANG

More information

esfr dry pendent sprinkler Vk501 (k14.0)

esfr dry pendent sprinkler Vk501 (k14.0) September 13, 2012 Sprinkler 122a 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK501 is a fast response fusible element type sprinkler designed for use in storage

More information

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

(Alarm Valve) & ' ( ()& * +,, & +-,. /0- (Alarm Valve). 8123-52 กก ก . 8123-52 1. 1.1 กก ก กก 1.2 1.2.1 ก (Alarm Valve) ก ก (Alarm Valve) (Alarm Valve) ก ก ก ก กก 1.2.2 ก (Alarm Valve) 25 (1 ) 300 (12 ) 1.2.3 ก (Alarm Valve) กก 2. กกก ก (Solid

More information

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION DIVISION 21 FIRE SUPPRESSION 21 00 00 FIRE SUPRESSION 21 01 00 Operation and Maintenance of Fire Suppression 21 01 10 Operation and Maintenance of Water Based Fire Suppression Systems 21 01 20 Operation

More information

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES SECTION 15300 FIRE PROTECTION PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. Dartmouth College is currently insured by Factory Mutual. References to the owner s insurance company in this specification

More information

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM Carbon dioxide (CO) is a well-known extinguishing system for electrical equipment. The system consists of liquefied CO stored in pressurised cylinder, discharge

More information

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE Page 1 of 8 1. DESCRIPTION Viking Deluge Systems utilize a Viking Deluge Valve to control the water supply to system piping equipped with open sprinklers and/or spray nozzles. The system piping remains

More information

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No SECTION 213113 - ELECTRIC-DRIVE, CENTRIFUGAL FIRE PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression

More information

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 Building Services Piping. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for

More information

TECHNICAL AND USER REQUIREMENTS FOR FIRE-FIGHTING PRESSURE HOSES FOR FIRE-FIGHTING PUMPS

TECHNICAL AND USER REQUIREMENTS FOR FIRE-FIGHTING PRESSURE HOSES FOR FIRE-FIGHTING PUMPS Centrum Naukowo Badawcze Ochrony PrzeciwpoŜarowej (Scientific and Research Centre for Fire Protection) Nadwiślańska 213, 05-420 Józefów, Poland Telephone (+48) 22 789 11 11 Fax.: (+48) 22 769 33 45 e-mail:

More information

FLEXIBLE CORRUGATED TUBE

FLEXIBLE CORRUGATED TUBE Back To The Natur e S O L A R S Y S T E M SPRINKLER SYSTEM B O I L E R FLEXIBLE CORRUGATED TUBE INSULATED SOLAR HOSES S Y S T E M w w w. k a s. c o m. t r SOLAR SYSTEM System Definition of Corrugated

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 422 Model E Alarm Check Valve Bulletin 422 Instructions for Installation, Operation, Care and Maintenance DN100, DN150, DN200 SIZE Model E with E2 Euro Trim The Reliable Automatic Sprinkler Co.,

More information

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment) LISTING NUMBER afp - 2086 Commonwealth Scientific and Industrial Research Organisation, Australia Ph.: 61 (0)3 9252 6000 Fax: 61 (0)3 9252 6011 Web site: http://www.activfire.gov.au E-mail: info@activfire.gov.au

More information

Gas Station & C Store SECTION CWM Job No

Gas Station & C Store SECTION CWM Job No SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint. (816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the

More information

Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom

Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom +44 (0)1642 611826 +44 (0)1642 617487 info.uk@aeon-online.com Aeon International

More information

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82  ASTM A 216 WBC. DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA NORMAL SIZE MATERIAL SEVICE PRESSURE THREADED OPENING MOUNTING FACTORY HYDOSTATIC TEST PRESSURE FLANGE CONNECTION WET PILOT SPRINKLER HEIGHT LIMITATION NET WEIGHT

More information

Hiren Industrial Corporation

Hiren Industrial Corporation +91-8048762355 Hiren Industrial Corporation https://www.indiamart.com/hirenindustrial/ We are reputed Manufacturers and Exporters, traders of Fire Fighting & Safety Equipment. We offer Safety Apparel,

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Standard response. elo sprinklers

Standard response. elo sprinklers Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent

More information

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements. FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment

More information

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d Page 1 of 7 This Trim Chart is for use with the following Viking Trim Sets Valve Size Galvanized Trim Part No. Brass Trim Part No. 3 (DN80) 14631-1 14631-2 4 (DN100) 14632-1 14632-2 6 (DN150) 14633-1 14633-2

More information

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS 000 model NO. LSS- 00 GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS Part number and descriptions can be obtained from the illustrated parts list section of this manual.

More information

Institute for Plasma Research Welcomes you all on

Institute for Plasma Research Welcomes you all on Institute for Plasma Research Welcomes you all on Presented By: D.V.MODI, Safety Officer, IPR Compiled by: SAFETY COMMITTEE, IPR WHAT IS FIRE? The self-sustaining process of rapid oxidation of a fuel,

More information

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM 1. GENERAL SPECIFICATION 1.1 An Engineered Carbon Dioxide Fire Suppression System shall be installed to meet a minimum design concentration of %, by volume in all designated spaces/areas to be protected.

More information

The Safest Connections...

The Safest Connections... The Fluid Manager The Safest Connections... The Lutz Accessory Range for Electrical & Pneumatic Drum, Tote and Container Pumps A c c e s s o r y R a n g e Accessory Range Safety is our Concern At a glance

More information

Discontinued Product

Discontinued Product SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Victaulic Series 759 alarm check valve works as a check valve by preventing the reverse flow of water from the system piping to the water supply. The valve

More information

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts Worldwide Contacts www.tyco-fire.com Model CV-F Grooved End Swing Check Valves General Description The TYCO Model CV-F Grooved End Swing Check Valves are compact and rugged swing-type units that allow

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE October 10, 2008 Deluge Devices 281a 1. PRODUCT DESCRIPTION The Viking Model C-1 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING SECTION 23 21 13 HYDRONIC PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes pipe and fitting materials, joining methods, special-duty valves, and specialties for the following: 1. Hot-water

More information

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION SECTION 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 - GENERAL 1.1 SUMMARY A. This section supplements all sections in this division, including pipe, fittings, valves, and connections for sprinkler

More information

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for

More information