1 NFPA 80 Overview January 21, 2016 Kristin Bigda, P.E. Senior Fire Protection Engineer National Fire Protection Association Presenter Kristin Bigda, P.E. Senior Fire Protection Engineer, NFPA Building Fire Protection and Life Safety Department Started NFPA in 2007 Bachelors of Science, Civil Engineering Masters of Science, Fire Protection Engineering NFPA 1, NFPA 101, NFPA 5000, NFPA 80, NFPA Overview Part 1 - NFPA 80 Overview and ITM requirements Part 2 - NFPA 80 FAQs/common compliance issues Part 3 NFPA 80, 2016 edition and the future 3 MFIS 1/21/2016 1

2 NFPA 80 why? 4 NFPA 80 why? 5 Part 1: NFPA 80, 2010 edition MFIS 1/21/2016 2

3 Document Scope This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls, floors, and ceilings against the spread of fire and smoke within, into, or out of buildings. 7 Revisions 1999 to 2007 Major Reorganization Manual of Style Title Change Broader Scope Fabric Fire Safety Curtains/Fire Dampers Care and Maintenance Updates to Chute Doors, Fire Shutters, Rolling Steel Doors and Service Counter Doors Swinging Doors 8 Current Document Organization (2007- present) Core Chapters Chapter 1-5 Doors Chapters 6-16 Other Opening Protectives Chapter 17-21* Annexes 9 MFIS 1/21/2016 3

4 Chapter 1 Scope Purpose Retroactivity Equivalency 10 Chapter 2 Referenced Publications NFPA ASME ASTM CSA BHMA UL 11 Chapter 3 Definitions 12 MFIS 1/21/2016 4

5 Chapter 4 General Requirements General Limitations Listed and Labeled Products Classifications and Types of Doors Glazing Material in Fire Doors Transparent Composite Panels Classification of Hardware for Fire Doors Placement of Detectors Supporting Construction Testing (moved to Ch.5 in 2013) 13 General - Appurtenances Accordance with manufacturer s inspection service procedure and under label service Permitted job-site preparation Holes for surface-applied hardware, function holes for mortise locks and holes for labeled viewers Max ¾ wood and composite door undercutting Installation of protection plates 14 General Signage 5% of the area of the face of the door Does not impair operation of the door Attached with adhesives 15 MFIS 1/21/2016 5

6 Listed and Labeled Products Hinges and Pivots Locks and Latches Door Closers/Coordinating Devices Fire Exit Hardware Door Attachments Protection Plates Louvers Astragals Gasketing Glazing 16 Classification-Door Types The hourly designation indicates the duration of the fire test exposure and is know as the fire protection rating. Fire door ratings 1/3-hour (20 minutes) 1/2-hour (30 minutes) 3/4-hour (45 minutes) 1-hour (60 minutes) 1-1/2 hour (90 minutes) 3 hour (180 minutes) Glazing Fire protection-rated Glazing that has a fire protection rating Indicates duration of fire test exposure which a fire door or window assembly was exposed and successfully met all acceptance criteria as in accordance with NFPA 252 or NFPA 257. Fire resistance-rated Glazing that has a fire resistance rating. The time, in minutes or hours, that materials or assemblies have withstood a fire exposure as established in accordance with the test procedures of NFPA MFIS 1/21/2016 6

7 Maximum Glazing Area 19 Placement of Detectors 20 Fusible Link Installation 21 MFIS 1/21/2016 7

8 Fusible Links (TIA 10-2) Where fusible links are installed on both sides of the wall, a sleeve shall be installed through the wall to provide an open pathway for the cable or chain connecting the fusible links. ½ diameter galvanized steel conduit or pipe. Free movement of cable or chain through the sleeve required. 22 Supporting Construction Sills Not required for noncombustible floors extended through the door opening. Required where combustible floor or floor covering extends through the door opening 2013: removed special sill, added definition for sill 23 Clearance Requirements Clearance. The clearance under the bottom of a door shall be a maximum of ¾ inch (19 mm). 24 MFIS 1/21/2016 8

9 Testing Upon completion of installation test is required to confirm operation of the closing device and full closure Moved to Chapter 5 for Swinging Doors Chapter 6 Swinging Doors with Builder s Hardware Typical components: door, a door frame, hinges, a lock or latch, and a closing device. They also include, but are not limited to, an astragal, a split astragal, an automatic louver, a coordinator, flush or surface bolts, gasketing, a holder/release device, protection plates, and glazing materials. Mounting Flush mounted in labeled door frames Operation closed and latched at time of fire: selfclosing, automatic-closing or power-operated 26 Builders Hardware Consists of components that are separate products incorporated into the assembly and allowed to have their own subcomponents. Components produced from more than one manufacturer Builders hardware shall not be required to be shipped from the factory with the fire doors. Fire EXIT hardware 27 MFIS 1/21/2016 9

10 Self-Closing Doors 28 Automatic-Closing 29 Swinging Fire Doors Chapter 6 Component based systems Labeled door frames Labeled doors Labeled or listed door hardware products Closing Devices required for every fire door, coordinating device required on pairs of doors where an astragal or latch bolt is present. Latching Positive latching required Hinges 2 hinges for doors up to 60 in height, additional hinge for every 30, shimming is permitted to assist with meeting clearance requirements. 30 MFIS 1/21/

11 Pivots and Continuous Hinges (2013) 31 Clearances Doors in Pairs 1/8 ± 1/16 for steel doors, 1/8 for wood doors 32 Swinging Doors Chapter 6 Locks and latches labeled locks and latches, labeled fire exit hardware installed only on fire doors with marking 33 MFIS 1/21/

12 Protection Plates Factory installed Labeled, accordance with listing of the door Field installed Labeled, accordance with their listing Label not required if <16 34 Swinging Doors Chapter 6 Astragals not allowed on doors swinging in pairs in the means of egress that would inhibit the free use of either leaf Gasketing permitted but not required, must be provided only in accordance with the published listings of the door, frame or gasketing material manufacturer. 35 Swinging Doors Chapter 7 Differences from Chapter 6: Type of hardware Construction of the door leaf and frame Sheet metal or tin-clad construction Larger in size (thickness, width, height) Hardware is generally not labeled separately (label on the door covers all the accessories and hardware) 36 MFIS 1/21/

13 Fire Door Hardware Consists of components that are separate products incorporated into the assembly. Hardware furnished by the fire door manufacturer Fire door hardware shall be shipped from the factory with the fire door. 37 Horizontally (8)/Vertical Sliding Doors (10) Door Panels Mounting Clearance Attachment Closing Devices/Speed Releasing Device Power Operated 38 Special Purpose Horizontally Sliding Doors (9) Photo courtesy of Won-Door Corporation 39 MFIS 1/21/

14 Rolling Steel Doors (11) Photo courtesy of Lawrence Doors 40 Fire Shutters (12) Three types Swinging (Chapter 6 or 7) Sliding (Chapter 8 or 10) Rolling (Chapter Service Counter Doors (13) Photos courtesy of Lawrence Doors 42 MFIS 1/21/

15 Elevator Hoistway Doors (14) 43 Chute Doors (15) 44 Access Doors (16) Horizontal or vertical Not a damper access door 45 MFIS 1/21/

16 Fire Windows (17) Testing NFPA 257 Labeling Window and frame require label, each unit required label visible after installation Installation fastened securely to the wall, capable of resisting stresses Operation Fixed or automatic closing 46 Other Opening Protectives Chapter 18 Glass Block Assemblies Chapter 19 Fire Dampers Chapter 20 Fabric Fire Safety Curtains Chapter 21 Fire Protective Curtain Assemblies (new, 2016) 47 Care and Maintenance Chapter 5 Application New and existing installations Doors, shutters, and windows. 48 MFIS 1/21/

17 Removal of a Door or Window Where a door or window opening is no longer in use, the opening shall be filled with construction equivalent to that of the wall. 49 Replacement Installed per new installation 50 Field Modifications New definition Field Modifications. Changes, not otherwise permitted by this standard, made to a listed assembly or component after it has been manufactured. Contact the lab with which product or component being modified is listed and description provided to lab. Field modifications permitted without a field visit from laboratory if authorized by the lab. Guidance for when a door/shutter/window manufacturer is no longer available. 51 MFIS 1/21/

18 Inspections and Testing Fire door assemblies shall be inspected and tested not less than annually, and a written record of the inspection shall be signed and kept for inspection by the AHJ. Functional Test Visual test 52 Documentation New for 2013: Date of inspection Name and address of facility Inspector name Name and address of inspecting company Signature of inspector of record Individual record of each inspected door assembly Identifier and location of each fire door assembly Type and description of each door assembly Verification of visual and functional operation List of deficiencies and corrective action 53 Record Retention (2013) Acceptance tests life of the assembly Other inspection and tests at least 3 years No mandatory format - paper or electronic are OK. 54 MFIS 1/21/

19 Fire Door Inspector Criteria (2013) * Acceptance testing of fire door and window assemblies shall be performed by a qualified person with knowledge and understanding of the operating components of the type of assembly being subject to testing. 55 Qualified Person Qualified Person. A person who, by possession of a recognized degree, certificate, professional standing, or skill, and who, by knowledge, training, and experience, has demonstrated the ability to deal with the subject matter, the work, or the project. 56 Performance Based Option 57 MFIS 1/21/

20 Minimum Items To Be Inspected (1) Labels are clearly visible and legible (2013) 58 (1) No open holes or breaks exist in surfaces of either the door or frame. 59 (2) Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. (Section 4.4, Glazing Material in Fire Doors) 60 MFIS 1/21/

21 (3) The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. (6.3.1, Door Frames, 6.4, Assembly Components) 61 (4) No parts are missing or broken. 62 (5) Door clearances at the door edge to the frame, on the pull side of the door, do not exceed clearances listed in and Photo courtesy of idighardware.com 63 MFIS 1/21/

22 (6) The self-closing device is operational, that is, the active door completely closes when operated from the full open position. (6.4.1, Closing Devices) 64 (7) If a coordinator is installed, the inactive leaf closes before active leaf. ( , Coordinating Device) 65 (8) Latching hardware operates and secures the door when it is in the closed position. (6.1.4, Operation of Doors, 6.4.4, Locks or Latches) 66 MFIS 1/21/

23 (9) Auxiliary hardware items that interfere or prohibit operation are not installed on the door or frame. ( , Field Modifications, Operation of Doors) 67 (10) No field modifications to the door assembly have been performed that void the label. ( Field Modifications) Photo courtesy of idighardware.com 68 (11) Gasketing and edge seals, where required, are inspected to verify their presence and integrity. (6.4.8, Gasketing) (13) Signage affixed to a door meets the requirements listed in (2013) 69 MFIS 1/21/

24 Door Blockage Photo courtesy of idighardware.com 70 Closing Mechanisms Photo courtesy of idighardware.com Kept in working conditions at all times. Doors with automatic-closing devices operated at frequent intervals to ensure operation. Sliding and rolling doors inspected and tested annually to check for operation. Resetting of release mechanism done in accordance with the manufacturer s instructions Written record maintained and available for the AHJ Rolling steel doors drop tested twice (first for operation and full closure, second to verify device has been reset. Fusible links are not painted, paint has not accumulated on any movable part. 71 Repairs - Damages For damages that it could impair the door s proper emergency function: (1) Repaired with parts obtained from the door s manufacturer. (2) The door shall be tested to ensure emergency operation and closing upon completion of the repairs. 72 MFIS 1/21/

25 Repairs Holes (fastener) 73 Who is responsible? Owners Inspectors AHJs 74 Part 2: FAQs and common deficiencies MFIS 1/21/

26 Functional Testing Q: Who does the inspection and testing? A: Functional testing of fire door and window assemblies shall be performed by individuals with knowledge and understanding of the operating components of the type of door being subject to testing 2013: * Acceptance testing of fire door and window assemblies shall be performed by a qualified person with knowledge and understanding of the operating components of the type of assembly being subject to testing. 76 Clearance Solutions Photo courtesy of idighardware.com 77 Painted Fire Doors Most fire rated doors are permitted painted in the field and the painting of fire doors does not compromise the fireprotection ratings of the door assemblies. 78 MFIS 1/21/

27 Fire Pins From NFPA 101, Life Safety Code (new in 2012) Door leaves shall be arranged to be opened readily from the egress side whenever the building is occupied * The requirement of shall not apply to door leaves of listed fire door assemblies after exposure to elevated temperature in accordance with the listing, based on laboratory fire test procedures. 79 Holes in Fire Doors 80 Grandfather Clause NFPA 80 is based on product and engineering practices recognized as acceptable at the date of issue. Not the intent that the provisions be applied to installations that were existing or approved for construction or installation prior to the effective date of the document. In those cases where it is determined by the AHJ that the existing situation involves a distinct hazard to life or property, retroactive application of the provisions of this document shall be permitted. Existing assemblies are required to comply with Chapter 5 for ITM provisions 81 MFIS 1/21/

28 Labeled vs. Listed Labeled. Equipment or materials to which has been attached a label, symbol, or other identifying mark of an organization that is acceptable to the authority having jurisdiction and concerned with product evaluation, that maintains periodic inspection of production of labeled equipment or materials, and by whose labeling the manufacturer indicates compliance with appropriate standards or performance in a specified manner * Listed. Equipment, materials, or services included in a list published by an organization that is acceptable to the authority having jurisdiction and concerned with evaluation of products or services, that maintains periodic inspection of production of listed equipment or materials or periodic evaluation of services, and whose listing states that either the equipment, material, or service meets appropriate designated standards or has been tested and found suitable for a specified purpose. 82 Does NFPA 80 address? A lot of items that we have to think about with fire doors don t come from NFPA 80: Door width Types of doors Door swing Door operation Locks and latches Forces to open the door Fire protection rating Labeling details 83 Other issues What issues do you see related to fire doors? 84 MFIS 1/21/

29 Part 3: NFPA 80, 2016 edition and beyond New! - Drilling Raceways New text permits drilling raceways for wires when performed at the job site Accordance with the door manufacturers listing and when permitted by the laboratory (Considered a field modification if no provisions in listing) 86 New! Label information through New provisions for information that must be included on a label Doors Frames Windows Oversized 87 MFIS 1/21/

30 New! Glazing Marking New! Oversized Doors New text addresses fire doors that are too large to be fire tested 89 Actuation Devices for doors, shutters and windows Section 4.7, updated and expanded text General Requirements Smoke detectors Heat detectors Fusible links 90 MFIS 1/21/

31 New! Doors exceeding bottom clearance Products evaluated for fire doors with a bottom clearance in excess of ¾ (19mm) and listed for use at or under the bottom of the fire door are permitted where installed in accordance with their listings. 91 New! Field Labeling Performed by individuals or companies that have been certified or listed, or that are representatives of a labeling service (proof of qualifications required) Field label information Modifications to non-fire rated doors 92 New! - Maintenance Procedures Fire door assemblies shall be inspected and tested upon completion of maintenance work Records required for all maintenance work 93 MFIS 1/21/

32 New! Repairing Fastener Holes in Door or Frame and Fastener holes are permitted to be filled with material listed for use and installed in accordance with the manufacturer s procedures Repairs to other holes in door or frame must be treated as a field modification 94 Clearances for Swinging Doors Door Hollow metal doors and frame HPDL face, 20 min flush wood doors, stile and rail wood doors installed in hollow metal frame HPDL face, flush wood doors, stile and rail wood doors > 20 min Other Clearance Maximum 1/8 +/- 1/16 (3.18 mm +/ mm) 1/8 +/- 1/16 (3.18 mm +/ mm) 1/8 (3.18 mm) 1/8 (3.18 mm), unless otherwise permitted in the door frame, door, or latching hardware man. pub. listing 95 New! - Thresholds When used, thresholds shall be noncombustible or listed. Revised definition of sill: A structural component of the building that forms the bottom part of an opening over which a door closes. New definition of threshold: A builders hardware component that is installed beneath a closed door 96 MFIS 1/21/

33 Chute Doors Chapter 15 Revised text to extract wholly from NFPA 82 Additional text for discharge and intake doors, general access and limited-access gravity chutes, and pneumatic chutes 97 New! Fire Dampers, Acceptance Testing 19.4 Adds new text regarding acceptance testing of fire dampers Qualified person Visual inspection Closing damper by all means Variable air volume system/heat-sensing elements Records 98 New! Fire Dampers, Periodic Testing New detailed requirements for test methods Fusible link operated dampers Dampers that do not use a fusible link to operate (motorized actuators) 99 MFIS 1/21/

34 New! Fire Protective Curtain Assemblies New Chapter 21 Addresses the installation, inspection, testing, and maintenance of fire protective curtain assemblies installed to protect vertical openings. Tested to UL 10D, Fire Tests for Fire Protective Curtain Assemblies New definition An assembly typically consisting of a fabric curtain, a bottom bar, guides, a coil, and an operating and closing system 100 Resources Document Information Pages Technical Questions Service NFPA 80 Handbook Annotated Edition MFIS 1/21/

35 2019 Edition Public Input Closing date June 29, 2016 First Draft Meeting September 2016 We need your input! 103 Thank you! MFIS 1/21/

Developing a Healthcare Facility Fire Door Inspection Program

Developing a Healthcare Facility Fire Door Inspection Program Developing a Healthcare Facility Fire Door Inspection Program WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio QUESTIONS How To Ask a Question: 1 POLLING There will be occasional interactive

More information

Fire Rated Door Assemblies: Compliant Designs

Fire Rated Door Assemblies: Compliant Designs Fire Rated Door Assemblies: Compliant Designs Steel Door Institute www.steeldoor.org AIA Provider #G389 Course #: SDIFIRE 1 HSW CE hour 1 Credit(s) earned on completion of this course will be reported

More information

Page 1 of 31 Second Revision No. 1-NFPA 80-2014 [ Section No. 2.3.2 ] 2.3.2 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM A36/A36M,

More information

Fire and Smoke Door Inspections Qualified Training 02/03/17

Fire and Smoke Door Inspections Qualified Training 02/03/17 Fire and Smoke Door Inspections Qualified Training 02/03/17 Basis of Requirements NFPA 101 requires annual fire and smoke door inspections (Section 18/19.2.2.2.1) Sections 18/19.2.2.1 require compliance

More information

Committee Input No. 1-NFPA [ Chapter 2 ]

Committee Input No. 1-NFPA [ Chapter 2 ] of 35 11/4/2016 6:18 PM Committee Input No. 1-NFPA 80-2016 [ Chapter 2 ] The committee will review and update the editions of the referenced publications to the correct edition at the Second Draft meeting.

More information

About the Instructor & Presenter:

About the Instructor & Presenter: About the Instructor & Presenter: Paul G. Baillargeon, AHC, FDAI Vice President, Technical Consulting Door Security & Safety Foundation A noted veteran in the door and hardware industry, Mr. Baillargeon

More information

NFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting.

NFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting. Input No. 7-NFPA 80-2013 [ Section No. 3.3.8 ] 3.3.8 Automatic Fire Detector. A device designed to detect the presence of a fire signature and to initiate action. For the purpose of this standard, automatic

More information

Swinging Egress and Fire Doors

Swinging Egress and Fire Doors Presented by: AHCA Seminar: Inspecting and Maintaining Swinging Egress and Fire Doors Current State CMS Memorandum July 28, 2017 Tuesday May, 3, 2016 CMS issued the final rule adopting the 2012 Life Safety

More information

WHAT TO EXPECT DURING A FIRE DOOR INSPECTION

WHAT TO EXPECT DURING A FIRE DOOR INSPECTION WHAT TO EXPECT DURING A FIRE DOOR INSPECTION Basic Fire Door Inspections 1. Fire door basic function 2. Understanding codes 3. Responsibility of end user 4. Common fire door deficiencies 5. What your door

More information

Laura Frye, AHC, CSI, CCS, FDAI Technical Director, DSSF Director of Certification, DHI

Laura Frye, AHC, CSI, CCS, FDAI Technical Director, DSSF Director of Certification, DHI Laura Frye, AHC, CSI, CCS, FDAI Technical Director, DSSF Director of Certification, DHI Inspecting Swinging Fire Doors with Builders Hardware A Practical Guide for AHJs and Facility Management Personnel

More information

2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance

2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance 2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance Will begin at 1 pm Housekeeping Announcements Problems during the call? Press *0

More information

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio 1 QUESTIONS How To Ask a Question: POLLING There will be occasional

More information

1-300 Fire and/or Smoke Dampers to Inspect $ Fire and/or Smoke Dampers to Inspect $34.30

1-300 Fire and/or Smoke Dampers to Inspect $ Fire and/or Smoke Dampers to Inspect $34.30 Life Safety Services, LLC TXMAS Schedule Contract Number: TXMAS-12-03FAC030 Passive Fire Protection Services Authorized Federal Supply Schedule Price List Quantity of Dampers to Inspect Per Damper to Survey

More information

Iowa State Fire Marshal

Iowa State Fire Marshal Iowa State Fire Marshal LIFE SAFETY CODE REQUIREMENTS LONG TERM CARE Kyle R. Gorsh, Special Agent in Charge Iowa Department of Public Safety State Fire Marshal Division 2012 LSC & Applicable Standards

More information

Design, Installation, Inspection, and Maintenance

Design, Installation, Inspection, and Maintenance Presents: Swinging Fire Door Assemblies with Builders Hardware Design, Installation, Inspection, and Maintenance About the Instructor & Presenter: Paul Baillargeon, AHC, FDAI A 40 year veteran in the Door

More information

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99 The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99 Sharon S. Gilyeat, P.E. Lauren Schrumpf August 8, 2018 Expertly Engineering

More information

AHCA Seminar: Inspecting and Maintaining Swinging Egress and Fire Door Assemblies

AHCA Seminar: Inspecting and Maintaining Swinging Egress and Fire Door Assemblies AHCA Seminar: Inspecting and Maintaining Swinging Egress and Fire Door Assemblies Today s Speakers Joseph A. Glaski, MBA, FASHE 20+ years as Director/VP of Facilities and Engineering Currently Director

More information

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES ANSI/DASMA 204-2004 AMERICAN NATIONAL STANDARD STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES Door & Access Systems Manufacturers Association, International Sponsor: 1300 Sumner Ave Cleveland, Ohio 44115-2851

More information

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. 9/20/2016 2:27 PM Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical

More information

SECTION OVERHEAD COILING FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS SECTION 08331 OVERHEAD COILING FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round Windows logo in top left corner,

More information

University of Rochester October 17, 2008 Brooks Landing Business Center

University of Rochester October 17, 2008 Brooks Landing Business Center SECTION 087100 - DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware. 2. Cylinders for doors specified in other Sections. 1.2 SUBMITTALS A. Product

More information

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES Sharon S. Gilyeat, P.E., Principal Koffel Associates, Inc. www.koffel.com sgilyeat@koffel.com Expertly Engineering Safety From Fire

More information

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

NFPA 101 Code Update from 2012 Edition to the 2015 Edition NFPA 101 Code Update from 2012 Edition to the 2015 Edition Presented by: Gary Furdell AHCA Fire Protection Specialist 1 2 2012 Update to 2015 Chapter 18 New Health Care Occupancies 4 18.1.3.2 Atrium walls

More information

Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form

Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form PART 1 GRAVITY CHUTES CHUTE DESIGN AND INSTALLATION INTAKE OPENINGS LIMITED ACCESS OFFSETS DIMENSIONS VENTING CONSTRUCTION

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General Requirements

More information

SECTION INTEGRATED DOOR ASSEMBLIES

SECTION INTEGRATED DOOR ASSEMBLIES SECTION 08 17 10 INTEG DOOR ASSEMBLIES SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Integrated

More information

Hands On Training for Fire Door Products and Fire Door Assemblies

Hands On Training for Fire Door Products and Fire Door Assemblies 2017 NFPA Conference & Expo Hands On Training for Fire Door Products and Fire Door Assemblies Presented by: Paul M. Goldense, FDAI Goldense Building Products, Inc. Jeffery S. Batick, FDAI Allegion Why

More information

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 47 10/21/2015 9:37 AM First Revision No. 5041-NFPA 101-2015 [ Global Input ] Throughout the document, change electrically controlled egress door assemblies to door hardware-release of electrically locked

More information

Life Safety - Means of Egress/Exits NFPA 101

Life Safety - Means of Egress/Exits NFPA 101 Life Safety - Means of Egress/Exits NFPA 101 Properly designed exits provide a safe path of escape from a fire or other emergency environment. The means of egress (exits) should be arranged to permit all

More information

TECHNICAL COMMITTEE MEMBERS PRESENT

TECHNICAL COMMITTEE MEMBERS PRESENT National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0770 www.nfpa.org MINUTES NFPA Technical on Fire Doors and Windows NFPA 80 and NFPA 105

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 94 ST - K0000 - Initial Comments Title Initial Comments Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 08 7100 DOOR HARDWARE A. Hardware for wood, aluminum, and hollow metal doors. B. Hardware for fire-rated doors. C. Electrically operated and controlled hardware.

More information

Report on First Revisions with Statement June 2014 NFPA 101

Report on First Revisions with Statement June 2014 NFPA 101 101 FR6005 SAF-BCF (32.2.1.1.2) Recommendation: 32.2.1.1.2 Where there are sleeping accommodations for more than 16 residents are provided, the occupancy shall be classified as a large facility in accordance

More information

Schools and the Fire Code A Partnership for Safety

Schools and the Fire Code A Partnership for Safety Schools and the Fire Code A Partnership for Safety Sue Birren, Fire Prevention Coordinator Department of Safety & Professional Services 5,100 fires occurred in educational occupancies in 2015 3,870 fires

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening. DIVISION 8 OPENINGS SECTION 08 33 23 PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead coiling counter fire doors. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Support framing and framed opening.

More information

Basic Fire Door Requirements

Basic Fire Door Requirements TECHNICAL DATA SERIES S D I 118-05 Basic Fire Door Requirements 2009 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2005 Basic Fire Door

More information

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors. PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: SECTION 08710 FINISH HARDWARE 1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors. 2. Types

More information

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials. B B11.0 DIVISION 08 - OPENINGS SECTION 08 17 00 INTEGRATED DOOR OPENING ASSEMBLIES Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section numbers and

More information

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS SECTION 08331 OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft

More information

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

First Aspen Federal Regulation Set: K LSC 2000 Health Existing First Aspen Federal Regulation Set: K 01.01 LSC 2000 Health Existing K 0000 Title CFR Type INITIAL COMMENTS Memo K 0011 If the building has a common wall with a nonconforming building, the common wall

More information

SAF-BCF SECOND REVISIONS WITH STATEMENTS

SAF-BCF SECOND REVISIONS WITH STATEMENTS Page 196 of 331 32.2.1.3 ] Second Revision No. 153-NFPA 101-2013 [ New Section after 32.2.1.4 Multiple-Level Buildings. For purposes of applying requirements of this chapter that utilize the term level

More information

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses PART 1 - GENERAL 1.1 SCOPE A. Through Class III Commodity Classification, up to 12.2m of single, double or multiple row rack storage, up to 14.6m building height (VanQuish Fire Sprinkler System). Cartoned

More information

Hand Chain (Model FCF) &

Hand Chain (Model FCF) & Hand Chain (Model FCF) & Hand Crank (Model FKF) INSTRUCTION MANUAL 0 WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing

More information

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR SECTION 08 71 13 LOW ENERGY AUTOMATIC OPERATORS Specifier Note: Coordinate and edit articles

More information

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical self-closing device

More information

Safety Tips for the Office

Safety Tips for the Office Safety Tips for the Office An office fire can be devastating - resulting in business interruption or permanent closure, loss of lives, jobs, property and information. Offices are loaded with combustible

More information

SECTION Overhead Coiling Doors

SECTION Overhead Coiling Doors SECTION 08 33 00 Overhead Coiling Doors To display hidden notes to specifier, select tools/ options/ view/ hidden text. GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 75 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K0100 - General Requirements - Other Title General Requirements - Other General Requirements - Other List in the REMARKS

More information

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 HCFMO Harris County Fire Marshal M.S. Montgomery Fire Marshal FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 EFFECTIVE JANUARY 1, 2007 These guidelines

More information

CHAPTER 7 ALTERATIONS LEVEL

CHAPTER 7 ALTERATIONS LEVEL CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration

More information

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE Developed by the Midwestern Regional Work Group CONTENTS Item 15 Limited area sprinkler systems Item 20 Scope of IFC Ch 7 Item 21 Fire-resistance-rated

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE McClellan Blakemore Architects New Warehouse Facility for SECTION 08710 DOOR HARDWARE PART 1 GENERAL 1.01 SECTION INCLUDES A. Hardware for wood and hollow steel doors. B. Hardware for fire-rated doors.

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Standards in Security Shutters & Fire Shutters (UK & USA)

Standards in Security Shutters & Fire Shutters (UK & USA) Standards in Security Shutters & Fire Shutters (UK & USA) Jason Powell 17.11.17 For UKRS Ltd Contents 1. Roller Shutter Safety Standards 1.1 UK / Europe 1.2 USA 2. Fire Shutter / Curtain Standards 2.1

More information

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016 Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016 Ohio Administrative Code Rule Number OMC Section IMC origin Reason for proposed 4101:2-2-01 Air, Makeup 2015 Modified definition Air,

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title

More information

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA Adoption of 2012 Life Safety Code Health Care Facilities Code Kenneth Daily, LNHA kenn@qissurvey.com CMS Announcement May 2016 Life Safety Code Health Care Code Effective July 5 th Numerous changes many

More information

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS The York County Department of Fire Safety reviews all commercial building plan submittals for compliance with the 2015 International

More information

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 43 10/28/2015 10:41 AM First Revision No. 6036-NFPA 5000-2015 [ Global Input ] Throughout the document, change door electrically controlled egress door assemblies to hardware-release of electrically

More information

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011 INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES 10-343 ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011 INSTRUCTION MANUAL FireGard Chain Operator (Model FCF) & FireGard

More information

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved Life Safety Code Common Discepancies Course# LSC102 EZpdh.com All Rights Reserved 1. K147 Electrical - Electrical wiring and equipment shall be in accordance with NFPA 70, National Electrical Code. 9.1.2

More information

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/201-7200 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us

More information

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Means of Egress

More information

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY 08 70 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes the design and coordination for all necessary hardware and coordination for all doors. Hardware shall include but not necessarily be limited to

More information

SECTION FIRE-SUPPRESSION STANDPIPES

SECTION FIRE-SUPPRESSION STANDPIPES PART 1 - GENERAL 1.1 DESCRIPTION Fire-suppression wet and manual dry standpipes. 1.2 SCOPE OF WORK SECTION 21 12 00 A. Design, installation and testing shall be in accordance with NFPA 14 except for specified

More information

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7 AGENDA: Life Safety Code Referenced Publications Overview Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99

More information

Barrier Management- Defending the Safety of Patients, Visitors, & Staff

Barrier Management- Defending the Safety of Patients, Visitors, & Staff Barrier Management- Defending the Safety of Patients, Visitors, & Staff About Your Speaker Rick Tinsley: 3 Years as Healthcare Construction Electrician 38 Years in Healthcare Facility Maintenance 13 Years

More information

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) The following represents a review of the Life Safety chapter of the new 2018 Joint Commission CAMH manual for

More information

ARCHITECTURAL SPECIFICATIONS

ARCHITECTURAL SPECIFICATIONS 1 B9.1 In Ground Page 1 of 6, Aug 12 DIVISION 08 - OPENINGS SECTION 08 71 13 POWER DOOR OPERATORS Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 200 SPECIFICATION Smoke Guard inc. 287 N. Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.639.7851 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

Osceola County Department of Fire Rescue and Emergency Medical Services

Osceola County Department of Fire Rescue and Emergency Medical Services St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner

More information

UL Revision 5. - Commercial Door Installations -

UL Revision 5. - Commercial Door Installations - UL325 2010 Revision 5 - Commercial Door Installations - UL325 - Scope - Door, Drapery, Gate, Louver, and Window Operators and Systems Covers electric operators for doors, draperies, gates, louvers, windows

More information

Report on First Revisions with Statement June 2014 NFPA 101

Report on First Revisions with Statement June 2014 NFPA 101 101 FR3002 SAF-HEA (18.1.3.2) Recommendation: 18.1.3.2 Atrium walls in accordance with 6.1.14.4.6 shall be permitted to serve as part of the separation required by 6.1.14.4.1 for creating separated occupancies

More information

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE MATRIX ADOPTION TABLE CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency

More information

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY Revision No.: 11 Page 1 of 12 I. PURPOSE This procedure establishes a tool to help maintain a safe environment for all patients, visitors and staff by evaluating the loss of a life safety feature during

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 75 ST - K0000 - Initial Comments Title Initial Comments Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0001 - OTHER

More information

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010) CHAPTER 1 SCOPE AND ADMINISTRATION 102.7 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 45 47 and such codes and standards shall

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 100 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS CFR Type Memo Tag FED - KA100 - General Requirements - Other

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 600 REV. 3 SPECIFICATION Smoke Guard, Inc 287 Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.639.7851 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

ICC CODE TECHNOLOGY COMMITTEE Area of Study Labeling of Fire Rated Glazing

ICC CODE TECHNOLOGY COMMITTEE Area of Study Labeling of Fire Rated Glazing ICC CODE TECHNOLOGY COMMITTEE Area of Study Labeling of Fire Rated Glazing Code Change History for 2006 IBC Section 75 Opening Protectives October, 2008 2006 IBC 200 IBC 2000 IBC APPLICABLE CODE CHANGES

More information

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD INSTALLATION OF COMMERCIAL FIRE SPRINKLER SYSTEMS STANDARD #C-001 EFFECTIVE 03-25-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

Fire Sprinkler Plan Submittal Form

Fire Sprinkler Plan Submittal Form Contents Fire Sprinkler Plan Submittal Form... 2 Standpipe Plan Review Submittals... 4 Fire Pump Plan Submittal Requirements... 6 Fire Alarm Plan Submittal Form... 8 Kitchen Hood Wet Chemical Submittal...10

More information

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] 4.3.11.5.5 Materials within a raised floor plenum exposed to the airflow shall be (a) noncombustible or (b) exhibit a maximum flame spread index of 25

More information

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME Section No. Subject Page No. 1 Authority and Purpose 10-1 2 Definitions

More information

For additional information regarding R-3.1 residential care facilities please contact (951)

For additional information regarding R-3.1 residential care facilities please contact (951) Riverside County Fire Department Fire/Life Safety Inspection Division Riverside Office: 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4823 Fax (951) 955-4886 Palm Desert Office: 77-933 Las

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 41 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K0011 - LIFE SAFETY CODE STANDARD If the building has a common wall with a nonconforming building, the common

More information

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Guy R. Colonna, PE Division Manager, NFPA Combustible Dust Symposium Detroit, MI September 20, 2011 1 Objectives

More information

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER SECTION 08 3493 AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Smoke detector-activated, vertical closing fire barrier conveyor system closure.

More information

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR SECTION 08734 COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead

More information

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY 08 70 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes the design and coordination for all necessary hardware and coordination for all doors. Hardware shall include but not necessarily be limited to

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 400 SPECIFICATION Smoke Guard, Inc. 287 N. Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.376.1600 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

rpsa FIRE PROTECTION ENGINEERS

rpsa FIRE PROTECTION ENGINEERS FIRE PROTECTION ENGINEERS R.P. SCHIFILITI ASSOCIATES, INC. P.O. Box 297 Reading, Massachusetts 01867-0497 USA 781.944.9300 Fax / Data 781.942.7500 Telephone Elevator Fire Safety: Elevator Recall and Elevator

More information

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Port of St Helens SIA Aircraft Hanger Scappoose, OR Port of St Helens SIA Aircraft Hanger Scappoose, OR AUTOMATIC FIRE SPRINKLER SYSTEM REVISION 2 MARCH 12, 2018 Scope: Furnish and install foam and water fire protection system including underground entrance

More information

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c Table 1015.1 EXIT ACCESS TRAVEL DISTANCE a WITHOUT SPRINKLER WITH SPRINKLER OCCUPANCY SYSTEM SYSTEM A, E, F-1, I-1, M, 200 250 b,d R, S-1 B 200 300 c F-2, S-2, U 300 400 c No Change to Other Entries in

More information

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification Second Revision No. 2011-NFPA 101-2016 [ Section No. 14.2.2.2.4 ] 14.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked to prevent unwanted entry

More information