MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation
|
|
- Amber Parks
- 5 years ago
- Views:
Transcription
1 Gas Detection Control Panel MX Analog and digital controller or 8 lines / 6 to s max Highly versatile controller Cost savings on wiring installation The Fixed Gas Detection People an company
2 Controller presentation The MX is an analog and digital controller designed for the continuous measurement and control of the gases present in the atmosphere and for - ma or digital contact signal. Large graphic display Smart keys make embedded menus simple to use Front panel LEDs allow a quick and basic overview of the installation. MX manages both digital lines and analog channels, and covers all needs for a wide variety of applications. The MX digital technology allows up to s to be distributed on 8 lines for increased cost savings. 6 Back-up battery Strobe and horn Power supply On-board relays Removable terminals 6 RS8 output 7 USB datalogging kit 7
3 Graphic Display In -channel display Normal Mode -% LEL methane 6 LM 8 7 Compressor 7 8h avg Compressor 7 7 See s Menu Measurement range, gas and tag Detector address Current value with unit and detected gas Averaged value on the last 8 hours Bar graph with alarm thresholds 6 Detector status (OK, OFF, fault) 7 MX status information 8 Records on progress By default, the MX can store up to alarm events, fault events and system events. Detector Zoom Gas alarms AL AL AL AL LM OLC T Zero Last Zoom + Calibration curve Cursors for span settings Measured value Calibration gas value Detector selection, zeroing and spanning 88 Level 8:: ESC Level Level Level Level Compressor A- Alarm Compressor A- VOTING / Alarm Detector OK Compressor A- Alarm Compressor A- AL 8:: OFF Alarm 8h: avg Normal Previous 8::9 COM configuration software LM OFF The Gb USB drive provides more than years of storage in most of configurations. The USB option also delivers the ability to save and restore configuration and firmware files. Alarm mode ON The USB option enables gas measurements to be saved at a sampling rate of seconds to minutes while events are saved when they happen. 7// Zoom - -% LEL methane 8::9 Delete Gas: Detector tag Event Date and time of events appearance or clearance Page number (up to 6 s) Span End 6/6 ON previous :: See 6 s Menu Data-logging Simplified procedure that enables time savings (i.e. non-intrusive and one man calibration). Up to 6 s can be displayed simultaneously Calibration Curve -% LEL methane previous Curve Turbine Detector OK At least line is OFF Previous Turbine Menu See s Alarm NAND Alarm Alarm Compressor A- Reverse video in alarm conditions for immediate identification of the concerned. Averaged value on the last 8 hours Detector status (OK, OFF, fault) MX status information Detector in alarm Siren Alarm Compressor A- Compressor A- Current value with unit and detected gas Compressor A- Curve AND N NAND VOTING Alarm Compressor A- OK Cancel Simple relay programming Up to embedded functions:, AND, N, NAND, VOTING Several timers available Advanced management of audible alarms (acknowledgment, reactivation, evacuation)
4 Gas detection control panel Modules Different modules can be connected to the controller: or 8-relay module 6-logic-input module or 8-programmablerelay module can be located closer to the actuators for cost savings. 8-analog-input module Addressable module of 6 logic input for recovery of digital information such as fire or intrusion alarms, emergency stop, limit switch activation, etc. -analog-output module This module enables standard analog transmitters (gas or flame s for instance) to be connected on a digital line for cost savings. Configuration example Addressable - analogoutput module which delivers analog -ma signal outputs ( output copy, min, max, average of a group of s) for connection to a datalogger, a PLC, a Building Management System (BMS), etc.
5 Specifications Model MX gas detection control panel Dimensions (wall-mounted version) 7 x 99 x 9 mm (.6 x.8 x. inches) Dimensions (rack) 9", U ; 8.8 x 77 x 9. mm (9. x 7 x 7.6 inches) Ingress protection IP (wall-mounted), IP (rack) Cable entries (wall-mounted version) M6 cable glands, to 8 mm² (8 to AWG) outer diameter cable 6 M cable glands, 6 to mm² (7 to 9 AWG) outer diameter cable Display LCD back-lit display + smart keys Display in video inverse in case of fault Customizable by user (display to 6 channels simultaneously, fixed or scrolling, on events...) Bar graph with alarm threshold Visual indicators 7 LEDs per line LED fault indicator LED fault indicator Buttons smart keys audible alarm accept/reset button Operating use Operating temperature - C to + C Storage temperature - C to + C Humidity to 9% RH Power - Vac -6 Hz or -8 Vdc, W max Battery Embedded back up power supply in option (.6 Ah) Consumption ma min (without module) Measurement lines Digital lines8 maximum RS-8 communication, proprietary protocol, 96 Baud twisted shielded-pair cable Analog channels8 maximum - ma analog signal input ( to ma reserved for measurement) Ohm load resistance or -core shielded cable Voltage (typical) to 8Vdc Maximum current output per line. A (. A intermittently) Maximum current output in total. A permanent (. A intermittently) Alarms Per channel alarm levels (A, A, A, Overscale, Underscale) + Fault Non-ambiguity reading option for combustible gases monitoring Programmable thresholds On instantenous ou averaged values, rising or falling alarms, manual or automatic acknowledgement On-board relays fully programmable alarm relays fault relay (non-configurable) Dry contact relay DPCO relays with contact rating of Vca A (inductive) Digital outputs RS-8 Modbus RTU serial link Approvals EMC According to EN7 ATEX EN7 and metrological performances according to EN Low Voltage Directive According to EN6 CSAPending MTBF years ( lines, powered with Vdc) 7 years (8 lines, powered with Vdc)
6 Our fixed range OLCT OLCT N CTX OLCT itrans OLCT 8 OLCT 6 OLCT 6 / OLCT IR OLCT IR SafEye Sharpeye AMERICAS Tel.: Fax: americas@oldhamgas.com EUROPE Tel.: Fax: info@oldhamgas.com ASIA PACIFIC Tel.: Fax: info@oldhamgas.com MX_Lit_EN_Oct
MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel
Gas Detection Control Panel MX Analog and digital controller or 8 lines / 6 to s max Highly versatile controller SIL reliability Fixed The Fixed Gas Gas Detection Detection Experts People www.oldhamgas.com
More informationAnalog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation
Gas Detection Control Panel Analog and digital controller 4 or 8 lines / 6 to detectors max Highly versatile controller Cost savings on wiring installation Certifications The The Fixed Fixed Gas Gas Detection
More information3M Oldham MX 43 Controller
Description Fully scalable, and designed to functional safety performance level standards, the MX is an analog and digital controller that continuously measures and controls gases in the atmosphere. The
More informationDetection, Protection, Innovation
MX3 CONTROLLER MX 3 CONTROLLER Analog and digital controller or 8 lines / 6 to 32 s max Highly versatile controller SIL reliability CERTIFICATIONS Detection, Protection, Innovation Oldham SAS has more
More informationDetectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.
Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI
More informationGlobal Gas Detection and Monitoring Solutions
Global Gas Detection and Monitoring Solutions With over 100 years experience in specialized safety, fire and gas detection systems, we are The Fixed Gas Detection Experts. www.oldhamgas.com At Oldham,
More informationSAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508
Open-Path Gas Detection System SAFEYE XENON 700 Hydrocarbons and ethylene detection Heated optics 10-year Warranty for the Xenon flash bulb SIL 2 according to IEC 61508 Certifications The Fixed Gas Detection
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More informationMX 32v2. User Manual. Analog and Digital Controller. The Fixed Gas Detection Experts. Part Number: NP32V2EN Revision: C.0
User Manual MX 32v2 Analog and Digital Controller Part Number: NP32V2EN Revision: C.0 The Fixed Gas Detection Experts Copyright January 2018 by Oldham S.A.S. All rights reserved. The reproduction of all
More informationMulti-Gas-Controller MGC2
Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants
More informationOLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.
FIXED GAS DETECTION OLCT 700 Series OLCT 700/710 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. &
More informationGas Controller Module GC-06
Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or
More informationOLC(T) 100 FIXED GAS DETECTOR
Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The
More informationUser Manual MX 43. Analog and Digital Controller. The Fixed Gas Detection Experts. Part Number: NPM43GB Revision: J.2
User Manual MX 43 Analog and Digital Controller Part Number: NPM43GB Revision: J.2 The Fixed Gas Detection Experts Copyright January 2019 by Oldham S.A.S. All rights reserved. The reproduction of all or
More informationLEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL
LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL The LeakMonitor alarm panel is a microprocessor controlled fully adjustable alarm system suitable for multizone
More informationYOUR PARTNER IN FIRE & GAS DETECTION
YOUR PARTNER IN FIRE & GAS DETECTION OGGIONI s.a.s. Via Lavoratori Autobianchi, 1 - P.T.B. Edif.13/O - 20832 Desio (MB) Italy Tel.+39 0362 629135 Fax. +39 0362 622531 www.oggionisas.com - info@oggionisas.com
More informationFixed Gas & Flame Detection Product Overview - EMEA Region
Fixed Gas & Flame Detection Product Overview - EMEA Region 1 Contents Fixed gas detectors Tertiary use 5 OLC 10 / OLCT 10 5 OLCT 10N 6 CTX 300 6 Car Park Solutions Fixed gas detectors Industrial use 7
More informationS5000 Gas Monitor. GMS5000.com
S5000 Gas Monitor GMS5000.com A DETECTOR AS TOUGH AS YOU ARE... LOWER TEMPERATURE SPEC?... ARCTIC WINTERS IT HAS TO BE THE MOST RELIABLE PIECE OF EQUIPMENT OUT HERE IF THE DETECTOR DOESN T WORK, WE DON
More informationSystem 57. An advanced World of intelligent gas detection system management
An advanced World of intelligent gas detection system management A World of control technology High precision, intelligent control Master / voted alarm options High packing density Flexible I/O configuration
More informationSystem 57. An advanced world of intelligent gas detection system management
An advanced world of intelligent gas detection system management A world of control technology High precision, intelligent control Master/voted alarm options High packing density Flexible I/O configuration
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors
More informationincontrol Systems Inc. Flame and Gas Detection
incontrol Systems Inc. Flame and Gas Detection Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial
More informationMX 15. Installation and Operating. Manual SINGLE CHANNEL CONTROLLER. The Fixed Gas Detection Experts. Part Number: NPM15GB Revision: C.
Installation and Operating MX 15 Manual SINGLE CHANNEL CONTROLLER Part Number: NPM15GB Revision: C.0 The Fixed Gas Detection Experts Copyright 2016 by Oldham April 2016 All rights reserved. Reproduction
More informationTouchpoint Pro Flexible Gas Control System
Gas Detection Touchpoint Pro Flexible Gas Control System THE IDEAL SAFETY SYSTEM Honeywell s Touchpoint Pro makes gas control system design, installation, configuration and operation simple. Touchpoint
More informationInc Series Digital Gas Detector/Controller. Operation Manual
5 Series Digital Gas Detector/Controller Operation Manual TABLE OF CONTENTS 1. 2. 3. 4. 5. 6. 7. General Description 1.1 Applications 1.2 Features Model Selection Guide Characteristics Installation 4.1
More informationSUPREMATouch Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of
More informationGAS PLUS ALARM SYSTEM
GAS PLUS -IR SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER GAS PLUS -IR TRANSMITTER SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER The Scott Gas Plus -IR Model 4688 IR Gas
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable
More informationDräger REGARD -1 Control System
Dräger REGARD -1 Control System The Dräger REGARD -1 is a standalone single-channel control system for the detection of toxic and Ex hazards and oxygen levels. The control system is fully configurable
More information4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head
4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel
More informationProducts and performance
Products and performance February 26, 2016 GfG Instrumentation overview of fixed system products Slide 1 GfG Instrumentation, Inc. 1194 Oak Valley Drive, Suite 20, Ann Arbor, Michigan 48108 Toll free (USA
More informationInstallation and Operating Manual MX 32 2 CHANNEL CONTROLLER. The Fixed Gas Detection Experts. Reference: NPM32GB Revision: B.1
Installation and Operating Manual MX 32 2 CHANNEL CONTROLLER Reference: NPM32GB Revision: B.1 The Fixed Gas Detection Experts Copyright 2013 by Oldham All rights reserved. Reproduction in any form, in
More informationZareba Metro Gas Detector
Zareba Metro Gas Detector The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards Metro Gas Detector One-Stop Shop Flammable and toxic gas monitors available Methane,
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in
More informationIndustrial Grade Gas Detection
Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0112 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen Europe Company Profile ISO 9001: 2008 Certified
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationVersion Inc Series Digital Gas Detector/Controller. Operation Manual
6000 Series Digital Gas Detector/Controller Version 000.02 Operation Manual TABLE OF CONTENTS 1.0 2.0 3.0 4.0 5.0 6.0 General Description 1.1 Applications 1.2 Features 1.3 Outputs 1.4 User Interface Model
More informationDetection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version
Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationDräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control
Dräger Elegant and smart... Explosive hazards and lack or surplus of oxygen under control Page 1 / December 2002 Two-In-One Instrument measures for explosive hazards and a lack or surplus of oxygen. It
More informationZareba System Overview
Zareba System Overview Examples of Gas Detection System Layouts Zareba Fixed Point Gas Detection Throughout the Building Services Industry, there are many different applications that require gas detection
More informationDigital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6
Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationWARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro
A d e v i h c r D c o n e m u WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship
More informationUniversal Gas Detector
Universal Gas Detector Instruction Manual PureAire Monitoring Systems, Inc. 557 Capital Drive Lake Zurich, Illinois 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 pureairemonitoring.com
More informationTHE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD
SYSTEM CENTERS FRANCE Dräger Safety France S.A.S. 3c, Route de la Fédération 67025 Strasbourg Cedex Tel +33 388 40 76 76 Fax +33 388 40 76 67 P. R. CHINA Beijing Fortune Draeger Safety Equipment Co., Ltd.
More informationModel D12-IR. Digital Gas Transmitter...
Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact
More informationAmmonia Leak Detector Manual
Ammonia Leak Detector Manual Document No. 70-PHW-1023-R2.5 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,
More informationIndustrial Grade Gas Detection
Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0912 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen UK Company Profile ISO 9001: 2008 Certified 105-A
More informationGas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2
Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation
More informationWarranty Registration
WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period
More informationTS400. Operating Manual. Test Station for Microtector II Series (G450/G460)
Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint
More informationOperating Manual GasGard XL Wall Mount Controller
Operating Manual GasGard XL Wall Mount Controller Order N. 10081908/05 For the Declaration of Conformity, please visit the product page on safety.com. Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona
More informationSensepoint XCL Fixed Gas Detector
Gas Detec on Sensepoint XCL Fixed Gas Detector Quick Start Guide Sensepoint XCL Fixed Gas Detector Quick Start Guide Read and understand the Sensepoint XCL Operating Instructions before installing, operating
More informationTransmitters/Sensors. OLCT Series
Transmitters/Sensors Gas Monitoring Solutions OLCT 20-40-50-60 Series SIL2 based on EN 50402 (OLCT 60 based on EN 50271) FLP approved Intrinsically Safe (IS) Precalibrated block module local or remote
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic
More informationDanfoss gas detection unit Type GD Heavy Duty
Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx
More informationDET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES
DET-TRONICS SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION Eagle Quantum Premier is a configurable, distributed, intelligent safety system providing flame
More informationSCAN200E USER S MANUAL
SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We
More informationSAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR
SAFETY MANUAL SIL 2 Certified Model FP-700 Combustible Hydrocarbon Gas Sensor Version 2.0 1 SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR This manual addresses the specific requirements and recommendations
More informationTouchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.
Touchpoint 1 The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards. Touchpoint 1 controller User Friendly Self-contained, wall mounted enclosure Ultra-clear
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationGas Detection. Touchpoint Plus. A whole new control experience
Gas Detection Touchpoint Plus A whole new control experience Touchpoint Plus Touchpoint Plus brings a whole new control experience to your small system of gas detectors. Touchpoint Plus is an easily configurable,
More informationSLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001
SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can
More informationOperating Manual. Gasgard 100 Control System. Order No.: /00. MSAsafety.com
Operating Manual Gasgard 100 Control System Order No.: 10153908/00 MSAsafety.com Warning! THIS MANUAL MT BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR ING OR SERVICING
More informationToxic and Explosive Smart Gas Monitor PN / Installation and User Manual
Toxic and Explosive Smart Gas Monitor PN 151022/151023 Installation and User Manual Quest Controls, Inc. 208 9 th Street Dr. West Palmetto, FL 34221 www.questcontrols.com Phone: (941) 729-4799 Fax: (941)
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationGas Detection System TOX ALARM DG2000-Garage
Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas
More informationIR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance
IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationOLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases
DETECTION DE GAZ FIXE OLCT Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Better detection. Better
More informationP R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.
More informationOxygen (O2) Single-Point Gas Detection System
Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity
More informationPolyGard Single Point Controller SPC-X3-34XX for Combustible Gases
PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring
More informationBS-316. Gas detection control panel up to 16 inputs. Installation operation manual
BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3
More informationRemote Display Alarm Indicator for Oxygen monitor
Remote Display Alarm Indicator for Oxygen monitor (Part number 99091) The Remote Display Alarm Indicator is designed to display remote oxygen concentration information from PureAire oxygen monitors. All
More informationOLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1
User Manual OLCT 10N Digital Gas Detector Part Number: NPO10NEN Version: G.1 The Fixed Gas Detection Experts Copyright 2015 by OLDHAM S.A.S May 2015 All rights reserved. No reproduction of all or part
More informationTHX-DL Data Logger USER & INSTALLATION MANUAL V
THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power
More informationALTAIR 5X Multigas Detector Product Specification
ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display
More information3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.
Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed
More informationPolyGard 2-channel Gas Controller MGC-03
PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air
More informationProduct Manual SZ1145
Product Manual SZ114 General Purpose Monitor Communicating Controls Description The SZ114 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum temperature
More informationSECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.
HGM300 / RDM800 Refrigerant Monitoring System Instruction 3015-4149 Installation & Operation Mini Manual Rev. 5 November 2004 SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.
More informationAir Check O 2 Deficiency Monitor 0-25%
Air Check O 2 Deficiency Monitor 0-25% Instruction Manual RS-485 Revision 4.05 Part number 99066 PureAire Monitoring Systems, Inc. 557 Capital Drive Lake Zurich, Illinois 60047 Phone: 847-726-6000 Fax:
More informationDräger REGARD 3900 Series Control System
Dräger REGARD 3900 Series Control System The devices of the Dräger REGARD 3900 series can be used as standalone controllers You can configure up to 16 measuring channels In addition, the modular setup enables
More informationFor Complete Fire and Gas Solutions
Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable
More informationMODEL 9010/9020 LCD CONTROL UNIT
Data Sheet MODEL 9010/9020 LCD CONTROL UNIT The Sophisticated Hazardous Gas Warning System Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 9010/9020 LCD Control Unit [ The Sophisticated
More informationTri-Stack Smart System
Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and
More informationIntelligent addressable fire alarm control panel
Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity
More informationDependable Solutions for Gas Detection
Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April
More informationGLD-30 Gas Leak Detector
GLD-30 Gas Leak Detector Installation, Operation & Maintenance General: The Archer Instruments GLD-30 is an ambient air monitor, used to detect the presence of a target gas (or gases) and to alert operators
More informationGas detection control system CM80-ID
Gas Detection Control Panel CM-80-ID Operator Manual Rev. 1.3.1 January 2014 Pag. 1/40 Gas detection control system CM80-ID Operator Manual January 2014 By OGGIONI s.a.s. Via Lavoratori Autobianchi, 1
More informationGasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08
GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,
More informationGas Detection System SGAES-TG Operating Manual R01
Gas Detection System SGAES-TG Operating Manual 80018-001 R01 Gas Detection Systems SGAES-TG Operating Manual 80018-001 R01 ESP Safety Inc 555 N. First Street San Jose, CA 95112 408-886-9746 April 2011
More informationDräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors
Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger
More informationDräger Polytron 8310 IR Detection of flammable gases and vapour
Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationPolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen
PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and