+ A B V B NO NC V COM PV PV
|
|
- Paul Paul
- 5 years ago
- Views:
Transcription
1
2 + - A + B B - V + - NO NC COM V + - PV PV
3 Ramp Soak Minute Steam Heating Sensor Cooling Water PID
4 Hotplate
5
6 Specifications Input power supply AC 100 to 240V, 50/60Hz, DC 24V ±10% Display meod LCD. Present Value: red, Set Value: green Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK Input sensors Platinum RTD: Pt100, JPt100 Analog input: 0 to 5V, 0 to 10V, 0 to 20mA, 4 to 20mA, 0 to 50mV Control modes PID, PID programmable, FUZZY, Self-tuning, manual, ON/OFF Display accuracy 0 or 1 digit to e right of e decimal point Sampling rate Analog input: 0.1s, Thermocouple or platinum RTD: 0.1s Ambient temperature 0 ~ +50 Ambient humidity 35 to 80% RH (non-condensing) Alarm Outputs The DT3 offers 3 alarm outputs, and each alarm output has 18 alarm modes to choose from in e initial setting mode. When e target temperature exceeds or falls below e set point, e alarm output is enabled. SV Alarm function disabled Alarm Mode Deviation upper- and lower-limit: This alarm output operates when PV value is higher an e set value SV+(AL-H) or lower an e set value SV-(AL-L). Deviation upper-limit: This alarm output operates when PV value is higher an e set value SV+(AL-H). Deviation lower-limit: This alarm output operates when PV value is lower an e set value SV-(AL-L). Absolute value upper- and lower-limit: This alarm output operates when PV value is higher an e set value AL-H or lower an e set value AL-L. Absolute value upper-limit: This alarm output operates when PV value is higher an e set value AL-H. Absolute value lower-limit: This alarm output operates when PV value is lower an e set value AL-L. Hysteresis upper-limit alarm output: This alarm output operates if PV value is higher an e set value SV+(AL-H). This alarm output is OFF when PV value is lower an e set value SV+(AL-L). Hysteresis lower-limit alarm output: This alarm output operates if PV value is lower an e set value SV-(AL-H). This alarm output is OFF when PV value is higher an e set value SV-(AL-L). Disconnection Alarm: This alarm output operates if e sensor connection is incorrect or has been disconnected. CT1 Alarm: CT1 is ON if e value of CT1 is lower an e value of AL-L or higher an AL-H. CT2 Alarm: CT2 is ON if e value of CT2 is lower an e value of AL-L or higher an AL-H. When SOAK status (temperature hold) happens to PID program control, alarm output is ON. When RAMP UP status happens to PID program control, alarm output is ON. When RAMP DOWN status happens to PID program control, alarm output is ON. When RUN status happens to PID program control, alarm output is ON. When HOLD status happens to PID program control, alarm output is ON. When STOP status happens to PID program control, alarm output is ON. When END status happens to PID program control, alarm output is ON. Alarm Output Operation ON OFF SV-(AL-L) SV SV+(AL-H) ON OFF SV SV+(AL-H) ON OFF SV-(AL-L) SV ON OFF AL-L AL-H ON OFF AL-H ON OFF AL-L ON OFF AL-L AL-H ON OFF AL-H AL-L ON OFF AL-L AL-H 5
7 RS-485 Communication DT3 supports baudrate 2,400 to 38,400 bps, MODBUS ASCII/RTU protocol, function code 03H and reads maximum 8 words from e register. Address 1000H 1001H 1002H 1003H 1005H 1006H 1007H 1008H 1009H 100AH 100BH 1012H 1013H 1016H 102AH 102BH 102CH 102DH 103BH 103CH Present value (PV) Set value (SV) Upper limit of temp. range Lower limit of temp. range Control mode Heating/cooling control st 1 heating/cooling control cycle nd 2 heating/cooling control cycle Proportional band (PB) Ti value Td value Read/write Output 1 volume Read/write Output 2 volume Regulated temp. value Read/write LED status Read/write key status Panel lockup status CT value AT setting Content Control RUN/STOP setting Measuring unit: 0.1 scale. The following values read mean error occurs. 8002H: Temperature not yet acquired 8003H: Not connected to sensor 8004H: Incorrect sensor Measuring unit: 0.1 scale. Cannot exceed e default value Cannot fall below e default value 0: PID, 1: ON/OFF, 2: Manual, 3: FUZZY 0: Heating/ Heating, 1: Cooling/ Heating, 2: Heating/cooling, 3: Cooling/ Cooling 0.1 ~ 99 sec. 0.1 ~ 99 sec. 0.1 ~ ~ ~ 9999 Unit: 0.1%, only valid in manual control mode Unit: 0.1%, only valid in manual control mode ~ +99.9, Unit: 0.1 b0: ALM3, b1: ALM2, b2: F, b3: C, b4: ALM1, b5: OUT2, b6: OUT1, b7:at b0: Set, b1: Select, b2: Up, b3: Down, 0: Press it 0: Normal, 1: Fully locked, 11: SV adjustable Unit: 0.1A 0: OFF(default), 1: ON Definition 0: STOP, 1: RUN (default), 2: END (program), 3: HOLD (program) 6
8 Parameters Operation Regulation Mode Press SET for less an 3 sec. Press SET Operation Mode Press SET for less an 3 sec. Press SET Initial Setting Mode Regulation Mode Operation Mode Initial Setting Mode Auto-tuning (when CTRL set in PID or FUZZY and in RUN mode) Press Self-tuning switch (set when in PID control and e TUNE parameter = ST) Select e n (n = 0 ~ 5) PID. When n = 6, PID is autoselected. Adjust Output 1 hysteresis (when in ON/OFF control) Use to set up target temperature Press Control loop RUN or STOP Set up start pattern (when in PID programmable control and ) Set up PID control offset Set up start step (when in programmable control) Set up FUZZY gain value Set up e position of decimal point Set up FUZZY Deadband Lock e keys Set up upper limit of Alarm 1 Set up input type Press Set up temperature unit (not displayed when in analog input) Set up upper temperature limit Set up upper temperature limit Select control modes Select SV control modes Set up waiting temperature (when in programmable control) Adjust Output 2 hysteresis (when in ON/OFF control) Control cycle for Output 1 (except in ON/OFF control) Control cycle for Output 2 (except in ON/OFF control) Ratio of Output 1 against Output 2 when in dual output control (set when in PID and dual output control) Set up deadband (when in dual output) Set up lower limit of Alarm 1 Set up upper limit of Alarm 2 Set up lower limit of Alarm 2 Set up upper limit of Alarm 3 Set up lower limit of Alarm 3 Set up waiting time (when in programmable control) Set up start slope (when in programmable control) Select pattern to be edited Select AT or ST Select heating, cooling or dual output heating and cooling Set up input filter factor Record highest temperature of Alarm 1 Set up input filter range Record lowest temperature of Alarm 1 Adjust input compensation Record highest temperature of Alarm 2 Adjust input gain Record lowest temperature of Alarm 2 Set up rising slope (when CRTS = SLOP) Record highest temperature of Alarm 3 Set up reverse alarm output Set up Remote type Set up Alarm 1 mode Set up Alarm 1 options Set up Alarm 1 delay Adjust upper limit compensation for analog Output 1* Record lowest temperature of Alarm 3 Select auxiliary function 7
9 Regulation Mode Operation Mode Initial Setting Mode Adjust lower limit compensation for analog Output 1* Adjust upper limit compensation for analog Output 2* Adjust lower limit compensation for analog Output 2* Adjust upper limit compensation for Retransmission* Adjust lower limit compensation for Retransmission* Adjust Remote gain Adjust Remote compensation Set up EVENT1 function Set up EVENT2 function Display and adjust Output 1 volume Display and adjust Output 2 volume Set up upper limit percentage for Output 1 Set up lower limit percentage for Output 1 Set up upper limit percentage for Output 2 Set up lower limit percentage for Output 2 CT1 CT2 Display current measured at Display current measured at Enable/disable communication write-in Select ASCII or RTU format Set up communication address Set up baudrate Set up data leng Set up stop bit Set up parity bit Set up EVENT3 function Press to return to auto-tuning Press to return to set up target temperature Press to return to set up input type *1 scale = 1μA; 1 scale = 1mV PID mode: Any of e 6 PID groups can be selected. When n = 6, e program will automatically select e PID group at is e closest to e target temperature. Select e n PID (n = 0 ~ 5) Set up e 0 PID temperature value Press Set up e 0 proportional band value Set up e 0 Ti value Set up e 5 PID temperature value Press Set up e 5 proportional band value Set up e 5 Ti value Set up e 0 Td value Set up e 5 Td value Press 0 ~ 5 PID Set up e 0 PID integral deviation Press to return to PID deviation Set up e 5 PID integral deviation Press to return to PID deviation Patterns and steps: Edit in parameter. Take editing pattern 0 for example: Select e pattern number to be edited Select number Press to select OFF Exit pattern and step editing and switch to to continue e setup process Edit temperature for Step 0 Select actual number of steps when e program is executing Press Press Edit time for Step 0 (time unit: hr, min) Set up Step 0 ~ 15 in order Edit temperature for Step 15 Edit time for Step 15 Press to set up actual step numbers Set up additional cycles (0 ~ 99) for e pattern execution Set up link pattern. OFF refers to e program end. Press to return to select e pattern number to be edited 8
10
11
12
13
14
15
16
17
18 Dimensions mm 44.0 mm 24.0 mm mm 48.0 mm 3.4 mm 99.8 mm 95.7 mm 98.2 mm 91.0 mm SET 48.0 mm 12.8 mm 79.2 mm mm 48.0 mm 9.5 mm 80.0 mm mm 72.0 mm 74.0 mm mm 72.0 mm mm mm 17
19 SET mm 98.0 mm 90.8 mm SET DTA mm 15.8 mm 79.2 mm DTC DTE
20 Industrial Automation Headquarters Delta Electronics, Inc. Taoyuan Technology Center No.18, Xinglong Rd., Taoyuan City, Taoyuan County 33068, Taiwan TEL: / FAX: Asia Delta Electronics (Jiangsu) Ltd. Wujiang Plant Jiangxing East Road, Wujiang Economic Development Zone Wujiang City, Jiang Su Province, P.R.C TEL: / FAX: Delta Greentech (China) Co., Ltd. 238 Min-Xia Road, Pudong District, ShangHai, P.R.C TEL: / FAX: Delta Electronics (Japan), Inc. Tokyo Office Minato-ku Shibadaimon, Tokyo , Japan TEL: / FAX: Delta Electronics (Korea), Inc. 1511, Byucksan Digital Valley 6-cha, Gasan-dong, Geumcheon-gu, Seoul, Korea, TEL: / FAX: Delta Electronics Int l (S) Pte Ltd. 4 Kaki Bukit Ave 1, #05-05, Singapore TEL: / FAX: Delta Electronics (India) Pvt. Ltd. Plot No 43 Sector 35, HSIIDC Gurgaon, PIN , Haryana, India TEL : / FAX : Americas Delta Products Corporation (USA) Raleigh Office P.O. Box 12173,5101 Davis Drive, Research Triangle Park, NC 27709, U.S.A. TEL: / FAX: Delta Greentech (Brasil) S.A. Sao Paulo Office Rua Itapeva, 26-3 andar Edificio Itapeva One-Bela Vista São Paulo-SP-Brazil TEL: / FAX: Europe Deltronics (The Neerlands) B.V. Eindhoven Office De Witbogt 15, 5652 AG Eindhoven, The Neerlands TEL: / FAX: *We reserve e right to change e information in is catalogue wiout prior notice. Delta_DT_C_EN_
Series Digital Controller Instruction Sheet
216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure
More informationSeries Temperature Controller Instruction Sheet
Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep
More information370, boulevard de Balmont LYON Tel Fax Web:
AUTOMATISME Régulateurs de température delta DELTA développe, dessine, fabrique des composants et des équipements électronique pour les plus importants constructeurs internationaux. Fort de ses 30.000
More informationSeries Temperature Controller Instruction Sheet
Series Temperature Controller Instruction Sheet Thank you very much for choosing Delta DTE series temperature controller. Please read this instruction sheet carefully before using your DTE to ensure proper
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationSerie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)
Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationTemperature Controller
E5AN Temperature Controller Temperature Controller OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku,
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationF4 Process Controller Installation and Operation Guide
F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationVERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER
1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning
More informationThe display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See
NEW»»» Changes in the color of the PV show the current status. You can select between different patterns for color combinations. If a certain status occurs, the status will be displayed alternating with
More informationCommunications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)
TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and
More informationTEMPERATURE CONTROL MODULE MODEL R3-TC2
INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...
More informationINSTRUCTION MANUAL Micro-computer based digital indicating controller
INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution
More informationInstruction manual Micro-computer based digital indicating controller
Instruction manual Micro-computer based digital indicating controller JCS-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual.
More informationMicro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e
C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...
More informationVT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL
Thermocouple Type BS4937 (IEC584-3): Outer / + / - BS1843 (Old UK Standard) Outer / + / - US Outer / + / - J : Iron / Copper-Nickel Black / Black / White Black / Yellow / Blue Black / White / Red VT4810
More informationInstruction manual for DIN rail mounting type indicating controller DCL-33A
Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution
More informationSafety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.
Temperature Controller KXN Series INSTRUCTION MANUAL Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product. Please check whether the prouduct you purchased is the exactly same as you ordered. Before using
More informationDIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL
DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL Preface Thank you for purchasing our Digital indicating controller FCS-23A. This manual contains instructions for the mounting, functions, operations
More informationExample of Applications and Parameter Functions
PX-series digital temperature controller Example of Applications and Functions ECNO:1158 I. Example of Applications 1 Controlling both heating and cooling with a single controller Only one controller is
More informationUDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 11/98 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 & UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers which
More informationCommunications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03
Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications
More informationWarning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER
INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER 1 DCL-A DC No.DCLDCE1 2007.01 Thank you for purchasing our DIN rail mounting type indicating controller DCL-A DC. This manual contains instructions
More informationTEMPERATURE CONTROLLER
TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response
More informationModel 96VTR ¼ DIN Process Controller
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 96VTR Product Info Page INSTRUCTION MANUAL Model 96VTR ¼ DIN
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable
More informationINSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A
INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 48VTR Product Info Page Instruction Manual English / Español
More informationARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER
ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4
More informationTempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications
Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates
More informationCN4800 Series CONTROLLER
CN4800 Series CONTROLLER Operator's Manual PV SV OUT1 OUT2 ALM1 ALM2 SEL M1791/0502 Contents I. PREPARING THE OPERATION... 4 1. THE BASIC INSTALLATION PROCEDURE... 5 2. CHECK OF SPECIFICATIONS... 6 2.1
More informationUser Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs
User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents
More informationTemperature Controller SA100. Initial Setting Manual IMR01J03-E1 RKC INSTRUMENT INC.
Temperature Controller SA100 Initial Setting Manual RKC INSTRUMENT INC. IMR01J03-E1 Modbus is a registered trademark of Schneider Electric. Company names and product names used in this manual are the trademarks
More informationTempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications
Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates
More informationNov 08 PRODUCT SPECIFICATION SHEET
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN
More informationGCS-300 No.GCS31E
INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller GCS-00 No.GCS1E 200.0 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.
More information7EF/7HF/7EC/7ES Temperature Controllers
7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent
More informationTECHNICAL BULLETIN [ 1/9 ]
TECHNICAL BULLETIN [ 1/9 ] [Title] Production Discontinuation of the PLC MELSEC-F Series Temperature Control Block FX2N-2LC [Date of Issue] April 2017 [Relevant Models] MELSEC-F series FX2N-2LC Thanks
More informationDIGITAL INDICATOR JIR-301-M
DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when
More informationUniversal controller for panel mounting Models CS6S, CS6H, CS6L
Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing
More informationInstruction manual Temperature Controller KT7
Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure
More informationUDC 700 Universal Digital Controllers and Indicator Specifications
UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality
More informationAutomationDirect. PC35 Configuration Sheet
Part#: Project: AutomationDirect PC35 Configuration Sheet Name: Date: Main Setpoint (): Cycle 5 INPUT DEFAULT CODE/VALUE Type 1 Dppo OFF Unit [ Offs 0 Spll -150 Spkl 1370 Rsll -150 Rskl 1370 Cycle 6 I/O
More informationNon-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100
INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.
More informationThe range of ATR243 controllers comes in three versions. Refer to the table below to easily select your preferred model.
Summary 1 Introduction... 3 2 Model Identification... 3 3 Technical Data... 4 3.1 General Features... 4 3.2 Hardware Features... 4 3.3 Software Features... 5 4 Dimensions and Installation... 5 4.1 Panel
More informationTerwin Instruments Ltd.
Terwin Instruments Ltd. Temperature PID Controllers MC-x8 OPERATIONAL MANUAL MC 8 / MC 8 / MC 8 MC 8 / MC 88 ( Display unit & Indication lamps ~ =Measured value display =Set value dispaly Alarm output
More informationGeneral Specifications
General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.
More informationSA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail
Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as
More informationMulti-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC.
Multi-point Digital Controller MA900/MA901 Initial Setting Manual RKC INSTRUMENT INC. IMR01H03-E4 !"Modbus is a registered trademark of Schneider Electric.!"Company names and product names used in this
More information4TEMPERATURE CONTROLLER
Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and
More informationDCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER DCL-A No.DCL1E5 200.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY
More informationUser Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs
User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents
More information4000 1/4 DIN /16 DIN /8 DIN
4000series 18 Quick Reference Guide PID Adjustment Guide iv Set-up Menu Press key for 3 seconds to enter the set-up menu. The flow chart shows a complete listing of all parameters. The number of available
More informationSA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting
Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller
More informationUDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationJIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.
INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY
More informationSYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1
SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 Jun. 2007 Auber Instruments, 730 Culworth, Alpharetta, GA 30022 www.auberins.com e-mail: auberins@gmail.com Tel: 404-291-6298 WARNING
More informationCONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual
Instruction Manual Micro-controller X Model : PXR5/9 INP-TNPXR5/9-E Head Office -, Osaki -chome, Shinagawa-ku, Tokyo, 4-3 Japan Sales Div. International Sales Dept. No., Fuji-machi, Hino-city, Tokyo, 9-85
More informationCommunications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02
Temperature Controller Fuzzy Self-tuning Temperature Controller with Advanced PID (2-PID) Control DIN-size: 6 x 6 mm (E5AJ), 2 x 2 mm (E5BJ), 4 x 4 mm (E5CJ), 4 x 6 mm (E5EJ) Fuzzy self-tuning and Auto-tuning
More informationTYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM
2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40
More informationINSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A
INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A Preface Thank you for the purchase of our Microcomputer based Temperature Indicating Controllers JCD-13A or
More informationDIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL
DIN RAIL MOUNTED INDICATING CONTOLLER DCL-A INSTRUCTION MANUAL Preface Thank you for purchasing our DIN rail mounted indicating controller DCL-A. This manual contains instructions for the mounting, functions,
More informationSS-100. Pyrometer. Temperature Range: 800~2400
Two Color Non-Contact Pyrometer Temperature Range: 800~2400 SS-100 GasDNA Co.,Ltd C-910C, Bupyeong Woolim Lion s Valley, #425, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510 E-mail:
More informationJIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.
INSTRUCTI MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E6 28.8 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY
More informationDigi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with
More informationUser s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com
TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN616A Universal 6 Channel ¼ DIN Process Controller omega.com info@omega.com U.S.A. Headquarters:
More informationCONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual. INP-TN1PXR5/9f-E
Instruction Manual Micro-controller X Model : PXR5/9 INP-TNPXR5/9f-E International Sales Div Sales Group Gate City Ohsaki, East Tower, -, Osaki -chome, Shinagawa-ku, Tokyo 4-, Japan http://www.fujielectric.com
More informationTAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller
TAIE FY Series Digital PID Controller FY600 (96mm X 48mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy
More informationMICRO CONTROLLER S Z SERIES
Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure
More information4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485
Select Option Device Wise Device/Group HumiLog Y-Axis Text Show/Hide Ledgends MIN MAX Scale Y Max 08-05-2015 15:17:59 PV_C PV_RH Color default default Graph Refresh Interval 2 Set Interval PV Low Alarm
More informationSX65 and SX75. Electronic process controllers
SX65 and SX75 Electronic process controllers A combination of simplicity and sophistication... The SX range of process controllers from Spirax Sarco has been designed after carefully considering both technical
More informationDC1000 Series Digital Controller Product Manual August 2005
DC1000 Series Digital Controller Product Manual 51-52-25-113 August 2005 Industrial Measurement and Control Copyright, Notices and Trademarks Printed in Taiwan - Copyright 2005 by Honeywell Revison 1 -
More informationINSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K
INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT PREFACE Thank you for your purchase of our Touch panel monitoring unit. This manual contains instructions for the mounting, functions, operations and
More informationUDC100 Universal Digital Controller Specifications
UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines
More informationHigh Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.
High Resolution Temperature Controller REX-F9000 Instruction Manual RKC INSTRUMENT INC. IM9000F01-E5 All Rights Reserved, Copyright 1999, RKC INSTRUMENT INC. Thank you for purchasing this RKC product.
More informationMC-5 Series Micro Processor Temperature Controller
MC-5 Series Micro Processor Temperature Controller Application Plastic, rubber, equipment Injection molding machinery Extruding machinery Mold temperature controllers Vacuum forming Blow molding (Thermo
More informationTAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller
TAIE FY Series Digital PID Controller FY900 (96mm X 96mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy
More informationMicro Controller PXR Series
Digital Temperature Controller Micro Controller PXR Series 2B-E-002 PXR Micro Controller PXR [] Features ( Except PXR3 ) [ 99mm ] [ 89mm ] [ 7272mm ] [ 88mm ] [ 28mm ] option RS8 communication Digital
More informationOX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E
Limiting-current type Oxygen Analyzer OX00, OX02 OX00, OX02 Limiting-current type Oxygen Analyzer One Instrument measures 00 ppm to 25% Oxygen Simple "One Touch" Calibration Self Diagnostics Assure High
More informationTable of Contents SECTION PAGE
Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................
More informationCONTENTS. Micro-controller X Model : PXR3. Instruction Manual
Instruction Manual Micro-controller X Model : PXR3 INP-TN1PXR3c-E Head Office 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-32 Japan Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo,
More informationNGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X
NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS Firmware versions up to V2.0.X INDUSTRIAL HEAT TRACING SOLUTIONS EN-RaychemNGCUIT2Protocol-IM-H57880 06/15 1/32 Contents Section I Introduction
More informationCT224 Setup Tutorial
CT224 Setup Tutorial Table of Contents 1. Introduction 2. Configuring Controller for Operation A. Example 1 Over Temp Operation with Hysteresis @ 5º F. B. Example 2 Under Temp Operation with Hysteresis
More informationCONTENTS. Instruction Manual Micro-controller X Model: PXR4
Instruction Manual Micro-controller X Model: PXR4 INP-TN1PXRa-E Fuji Electric Co., Ltd. Head Office 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-32 Japan http://www.fujielectric.co.jp Fuji Electric Instruments
More informationTemperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI
HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module
More informationModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.
ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page
More informationCONTENTS. Micro-controller X Model : PXR4, PXR7. Instruction Manual. INP-TN1PXRj-E
Instruction Manual Micro-controller X Model : PXR4, PXR7 INP-TNPXRj-E Head Office Gate City Ohsaki, East Tower, -2, Osaki -chome, Shinagawa-ku, Tokyo 4-32, Japan http://www.fesys.co.jp/eng Instrumentation
More informationHumidity Controller Specification and Installation Instructions. Model HRO20
Model Description The Humidity Controller is an advanced application to control relative humidity for general purpose applications. They are specially designed to control humidifiers and dehumidification
More informationMICRO CONTROLLER E Z SERIES
Instruction Manual MICRO CONTROLLER E Z SERIES TYPE: PYZ 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN2PYZDe-E INTRODUCTION You are now the owner of Fuji's Digital Temperature Controller. Before using, be sure
More informationBench-Top Vacuum Oven with 28 segments programmable controller
Bench-Top Vacuum Oven with 28 segments programmable controller DZF-6000F Series Vacuum Oven MTI Corporation www.mtixtl.com 1 Safety notes DZF Vacuum Oven Please read the following safety notes carefully
More informationLCF Touch Modbus Datasheet Application Security Advice Caution
LCF Touch Modbus Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room
More informationVTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL
VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL 1 Operations Manual for the VTI Model itc5000 Heat Tracing Control System Description The VTI Model itc5000 Heat Tracing Control System consists
More informationInstaller Manual KNX Touchscreen Thermostat
Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY
More informationOakton TEMP 9500 Advanced Multiparameter Controller
Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents
More informationHardware Instruction Manual. SR Mini HG SYSTEM. High-performance Multi-point Control System IMSRM15-E4 RKC INSTRUMENT INC.
SR Mini HG SYSTEM High-performance Multi-point Control System SR Mini HG SYSTEM Hardware Instruction Manual RKC INSTRUMENT INC. RKC www.rkc-usa.com Distributed By (800) 576-6308 Inc, IMSRM15-E4 All Rights
More information