Public Comment No. 16-NFPA 13D-2014 [ Section No ]

Size: px
Start display at page:

Download "Public Comment No. 16-NFPA 13D-2014 [ Section No ]"

Transcription

1 of 52 9/22/2014 9:20 AM Public Comment No. 16-NFPA 13D-2014 [ Section No ] ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA ASTM A 53 A53/A53M, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless, ASTM A 135 A135/A135M, Standard Specification for Electric-Resistance-Welded Steel Pipe, 2009 (2014). ASTM A 234 A234/A234M, Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service, e1. ASTM A 795 A795/A795M, Standard Specification for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use, ASTM B 32 B32, Standard Specification for Solder Metal, ASTM B 43 B43, Standard Specification for Seamless Red Brass Pipe, ASTM B 75 B75/B75M, Standard Specification for Seamless Copper Tube, ASTM B 88 B88, Standard Specification for Seamless Copper Water Tube, ASTM B 251 B251, Standard Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube, ASTM B 813 B813, Standard Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and Copper-Alloy Tube, ASTM B 828 B828, Standard Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings, 2002 (2010). ASTM F 437 F437, Standard Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80, ASTM F 438 F438, Standard Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40, ASTM F 439 F439, Standard Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80, ASTM F 442 F442/F442M, Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR), e1. ASTM F 876 F876, Standard Specification for Crosslinked Polyethylene (PEX) Tubing, a. Statement of Problem and Substantiation for Public Comment standards date updates Related Item First Revision No. 1-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Marcelo Hirschler Organization: GBH International Street Address: City: State: Zip: Submittal Date: Sun Apr 27 17:34:28 EDT 2014

2 of 52 9/22/2014 9:20 AM Committee Statement Committee Action: Rejected but see related SR Resolution: SR-1-NFPA 13D-2014 Statement: standards date updates

3 of 52 9/22/2014 9:20 AM Public Comment No. 29-NFPA 13D-2014 [ Section No ] ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA ASTM A 53/A 53M, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless, ASTM A 135/A 135M, Standard Specification for Electric-Resistance-Welded Steel Pipe, ASTM A 234/A234M, Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service, e1. ASTM A 795/A 795M, Standard Specification for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use, ASTM B 32, Standard Specification for Solder Metal, ASTM B 43, Standard Specification for Seamless Red Brass Pipe, ASTM B 75, Standard Specification for Seamless Copper Tube, ASTM B 88, Standard Specification for Seamless Copper Water Tube, ASTM B 251, Standard Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube, ASTM B 813, Standard Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and Copper-Alloy Tube, ASTM B 828, Standard Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings, (2010). ASTM F 437, Standard Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80, ASTM F 438, Standard Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40, ASTM F 439, Standard Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80, ASTM F 442, Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR), e1. ASTM F 876, Standard Specification for Crosslinked Polyethylene (PEX) Tubing, a. Statement of Problem and Substantiation for Public Comment Update year dates for standards Related Item First Revision No. 1-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Steve Mawn Organization: ASTM International Street Address: City: State: Zip: Submittal Date: Thu May 15 14:58:00 EDT 2014 Committee Statement

4 of 52 9/22/2014 9:20 AM Committee Action: Rejected but see related SR Resolution: SR-1-NFPA 13D-2014 Statement: standards date updates

5 of 52 9/22/2014 9:20 AM Public Comment No. 5-NFPA 13D-2014 [ Section No ] Sprinkler System. For fire protection purposes, A system that consists of an integrated system network of underground and overhead piping designed in accordance with fire protection engineering standards. The installation includes one or more automatic water supplies that includes a water supply source, a water control valve, a waterflow alarm, and a drain and is commonly activated by heat from a fire, discharging water over the fire area. The portion of the sprinkler system aboveground above ground is a network of specially specifically sized or hydraulically designed piping installed in a building, structure, or area, generally overhead, and to which sprinklers are attached in a systematic pattern. The system is usually commonly activated by heat from a fire and discharges water over the fire area. [ ] New A A waterflow alarm, although included in this definition, is not a required system component within this standard. Statement of Problem and Substantiation for Public Comment This change would permit consistancy with NFPA13. The additional anex material serves to clarify that the waterflow switch is not a required system component. Related Item Public Input No. 6-NFPA 13D-2012 [Section No ] Submitter Information Verification Submitter Full Name: Mark Fessenden Organization: Tyco Fire Protection Products Street Address: City: State: Zip: Submittal Date: Tue Mar 11 12:10:38 EDT 2014 Committee Statement Committee Action: Resolution: Rejected The definition should not be extracted from NFPA 13 since waterflow alarms are not required in NFPA 13D systems. An idenpendent definition of sprinkler system is needed for this standard.

6 of 52 9/22/2014 9:20 AM Public Comment No. 9-NFPA 13D-2014 [ Section No. 4.5 ]

7 of 52 9/22/2014 9:20 AM 4.5 * Documentation.

8 of 52 9/22/2014 9:20 AM Documentation shall be available upon request to ensure adequate water supply, listed devices, and adequate sprinkler coverage have been addressed. 4.5 * Documentation. Documentation shall be available upon request to ensure adequate water supply, listed devices, and adequate sprinkler coverage have been addressed. Working Plans. Working plans shall be drawn to an indicated scale, on sheets of uniform size, with a plan of each floor, and shall show those items from the following list that pertain to the design of the system: (1) Name of owner. (2) Location, including street address. (3) Point of compass. (4) Full height cross section. (5) Ceiling/roof heights and slopes not shown in the full height cross section. (6) Location of partitions, lintels, and doorways. Lintel openings require a cross section view to indicate the area of the opening. (7) Name and label for each area or room. (8) For systems supplied by city mains, location and size of city main in street, and location, size, and type of domestic line, including length to city connection, and water meter location and size. Static and residual hydrants that were used in flow tests shall be shown. The location of the 5 gpm domestic demand shall be indicated. (9) Make, type, model, temperature rating, nominal K-factor, and number of each type of sprinkler, including sprinkler identification number. (10) Pipe type and schedule of wall thickness. (11) Nominal pipe size and cutting lengths of pipe (or center-to-center dimensions). Where typical branch lines prevail, it shall be necessary to size only one typical line. (12) Location and size of riser nipples and drops. (13) Type of fittings and joints. (14) Type and locations of hangers, and methods of securing sprinklers when applicable. (15) Location and size of all valves and drain pipes. (16) Location and size of water gauges. (17) Where the equipment is to be installed as an addition to an existing system, enough of the existing system indicated on the plans to make all conditions clear. (18) A summary of the hydraulics, including the static pressure, residual pressure, and flow of the water supply, the pressure and flow demands at the point of connection to the water supply, and the pressure and flow demands at the bottom of the system riser. (19) Hydraulic reference points shown on the plan that correspond with comparable reference points on the hydraulic calculation sheets. (20) Relative elevations of sprinklers, junction points, and supply or reference points. (21) A graphic representation of the scale used on all plans. (22) Name, address, phone number of the contractor. (23) Where required by the AHJ, documentation of the designer credentials. (24) Indicate by note the minimum rate of water application per sprinkler head, the maximum spacing for each head, and the domestic demand. (25) Information about antifreeze solution used. Indicate the type of antifreeze used, the amount of antifreeze in the system, and information about antifreeze compatibility with the pipe. (26) General notes as required by the AHJ. (27) Edition year of NFPA 13D to which the sprinkler system is designed. (28) Utility plans and/or plumbing plans necessary to show connection from water supply to fire sprinkler system.

9 of 52 9/22/2014 9:20 AM Statement of Problem and Substantiation for Public Comment The TC states that the material in A.4.5 adequately covers the materials necessary for documentation. We agree with the TC that the information in A.4.5 is truly necessary documentation for a review of a 13D submittal. Being necessary information, it should not be contained in the annex but should be contained in the core text. This requirement is specifically stated in the Manual of Style section The annexes of codes and standards shall be used for advisory text, explanatory material, and supplementary information and shall not be used for mandatory requirements. If the requirements of A.4.5 are truly necessary, and we agree with the TC that they are, then the text clearly has to be mandatory in order for a necessary requirement to be provided by the designer and reviewed by the AHJ. In addition, if necessary information is not provided as part of an initial permit submittal for an AHJ to review the sprinkler design for compliance with NFPA 13D, the TC is basically mandating that the AHJ is going to reject the first submittal of each 13D system because the necessary information for a review has not been submitted. This creates additional time delays and additional costs which is directly counter to the TC s concern that of avoiding unnecessary costs. Related Item Public Input No. 32-NFPA 13D-2013 [Section No. 4.5] Submitter Information Verification Submitter Full Name: Bill Galloway Organization: Southern Regional Fire Code De Street Address: City: State: Zip: Submittal Date: Thu Apr 17 12:59:31 EDT 2014 Committee Statement Committee Action: Resolution: Rejected Items 5, 7, 8, 11, 14, 18 and 19 in this public comment all require documentation of items that are not required by the standard. The items that are included in this comment that are required in the standard should be included on a project by project basis as determined by the AHJ. Requiring working plans for NFPA 13D systems will drive up the cost of the systems and could impact the use and adoption of the standard.

10 0 of 52 9/22/2014 9:20 AM Public Comment No. 26-NFPA 13D-2014 [ Section No ] * Where a sprinkler is removed from a fitting or welded outlet, it shall not be reinstalled except as permitted by * Dry sprinklers shall be permitted to be reinstalled, where they are not removed by applying torque at the point where the sprinkler is attached to the barrel. its listing. Statement of Problem and Substantiation for Public Comment Regarding the change proposed by FR #2, NFPA's Building Code Development Committee believes consideration should at least be given when the sprinkler manufacturer has specified a removal method as is explained in Thomas Deegan s negative vote comments. This makes the provision more succinct. Note that this is related to our Public Comment relocating the Annex material in A to A Related Public Comments for This Document Related Comment Public Comment No. 27-NFPA 13D-2014 [Section No. A ] Public Comment No. 27-NFPA 13D-2014 [Section No. A ] Related Item First Revision No. 2-NFPA 13D-2013 [New Section after 5.1.1] Relationship Submitter Information Verification Submitter Full Name: Jim Muir Organization: Building Safety Division, Clark County, Washington Affilliation: NFPA's Building Code Development Committee (BCDC) Street Address: City: State: Zip: Submittal Date: Thu May 15 12:26:56 EDT 2014 Committee Statement Committee Rejected but see related SR Action: Resolution: SR-2-NFPA 13D-2014 Statement: The first draft language eliminates the possibility of removing dry sprinklers with a head wrench even if the manufacturer recommends it. At least one manufacturer recommends installing and removing their dry sprinklers with a head wrench. The wording has been modified to allow the use of a head wrench if the manufacturer recommends it.

11 1 of 52 9/22/2014 9:20 AM Public Comment No. 10-NFPA 13D-2014 [ Section No ] Tanks, expansion tanks, gauges, pumps, hangers, waterflow detection devices, and valves shall not be required to be listed. Statement of Problem and Substantiation for Public Comment Gauges are not always required but when they are utilized, should not be required to be listed. Related Item First Revision No. 3-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Peter Schwab Organization: Wayne Automatic Fire Sprinkler Street Address: City: State: Zip: Submittal Date: Thu Apr 17 13:12:50 EDT 2014 Committee Statement Committee Action: Accepted Resolution: SR-4-NFPA 13D-2014 Statement: Gauges are not always required but when they are utilized, should not be required to be listed.

12 2 of 52 9/22/2014 9:20 AM Public Comment No. 7-NFPA 13D-2014 [ New Section after ] When pipe differing from those specified in Table is to be used, it shall be installed behind a thermal barrier of not less than 1/2 inch gypsum board unless specifically listed to be installed without protection. Statement of Problem and Substantiation for Public Comment Don t feel that the committee statement is completely true. Fire officials need to have this additional guidance available in the Standard in order to make it more available than merely being noted in the pipe s listing and manufacturers installation instructions. Related Item Public Input No. 24-NFPA 13D-2013 [Section No [Excluding any Sub-Sections]] Submitter Information Verification Submitter Full Name: John Chartier Organization: Northeastern Regional Fire Cod Street Address: City: State: Zip: Submittal Date: Mon Apr 07 11:56:22 EDT 2014 Committee Statement Committee Action: Resolution: Rejected The use of specially listed piping materials is permitted by this standard. These products are intended to be installed in accordance with their listing. Any special installation and/or piping protection requirements unique to the product listing should be obtained from the manufacturer's installation instructions and technical manuals and are not intended to be specifically addressed within this standard.

13 3 of 52 9/22/2014 9:20 AM Public Comment No. 8-NFPA 13D-2014 [ New Section after 5.3 ] 5.3* Underground Pipe Type. Any type of pipe or tube acceptable under the applicable plumbing code for underground supply pipe shall be acceptable as an underground supply for a fire sprinkler system when installed between the point of connection and the system riser Depth of Cover Except where specified otherwise by the applicable plumbing code, the top of the pipe shall be buried not less than 1 ft (0.3 m) below the frost line for the locality. In those locations where frost is not a factor, the depth of cover shall be not less than 2½ ft (0.8 m) to prevent mechanical damage The depth of cover over water pipes shall be determined by the maximum depth of frost penetration in the locality where the pipe is laid. The depth of cover shall be measured from the top of the pipe to finished grade, and due consideration shall always be given to future or final grade and nature of soil Protection Against Damage. Unless specified otherwise by the applicable plumbing code, the pipe shall be protected from mechanical and physical damage. Statement of Problem and Substantiation for Public Comment The text comes from NFPA 24. There are many areas in the country that do not have a plumbing code and the text would provide guidance to them. Alos do to the recent harsh winters additional quidance needs to be provided to them. Not all jurisdictions employ a plumbing code. Some adopted plumbing codes don t address these concerns or does not address fire service mains. The proposal addresses the minimum guidelines when not otherwise addressed by the local plumbing code and recognizes a hierarchy that establishes that the local plumbing code takes precedence. Related Item Public Input No. 29-NFPA 13D-2013 [Section No. 5.3] Submitter Information Verification Submitter Full Name: John Chartier Organization: Northeastern Regional Fire Cod Street Address: City: State: Zip: Submittal Date: Mon Apr 07 12:01:02 EDT 2014 Committee Statement Committee Action: Resolution: Rejected The submitter provided no additional technical substantiation for the depth of cover values as they pertain to residential homes. As indicated in the first draft report these requirements would make NFPA 13D more restrictive than NFPA 13R and add significant cost to the system. The submitter is encouraged to provide technical data substantiating these values and submit a PI in the next cycle.

14 4 of 52 9/22/2014 9:20 AM Public Comment No. 28-NFPA 13D-2014 [ Section No. 5.3 ] 5.3 * Underground Pipe. Any type of pipe or Pipe or tube acceptable under the applicable plumbing code for underground supply pipe shall be acceptable as an underground supply for a fire sprinkler system when installed between the point of connection and the system riser. Statement of Problem and Substantiation for Public Comment NFPA's Building Code Development Committee (BCDC) agrees with the submitter of Public Input #18 that this is editorial. The Technical Committees reason for not developing a First Revision does not make sense. Related Item Public Input No. 18-NFPA 13D-2013 [Section No. 5.3] Submitter Information Verification Submitter Full Name: Jim Muir Organization: Building Safety Division, Clark County, Washington Affilliation: NFPA's Building Code Development Committee (BCDC) Street Address: City: State: Zip: Submittal Date: Thu May 15 12:56:34 EDT 2014 Committee Statement Committee Action: Rejected Resolution: The word "any" is helpful to AHJs who are trying to enforce this section.

15 5 of 52 9/22/2014 9:20 AM Public Comment No. 32-NFPA 13D-2014 [ New Section after ] Small areas created by architectural features such as planter box windows, bay windows, and similar features shall be evaluated as follows: (1) Where no additional floor area is created by the architectural feature, no additional sprinkler protection is required. (2) Where additional floor area is created by an architectural feature, no additional sprinkler protection is required, provided all of the following conditions are met: (a) (b) (c) (d) The floor area shall not exceed 18 ft 2 (1.7 m 2 ). The floor area shall not be greater than 2 ft (0.61 m) in depth at the deepest point of the architectural feature to the plane of the primary wall where measured along the finished floor. The floor shall not be greater than 9 ft (2.7 m) in length where measured along the plane of the primary wall. Measurement from the deepest point of the architectural feature to the sprinkler shall not exceed the maximum listed spacing of the sprinkler. (3) The hydraulic design is not required to consider the area created by the architectural feature. Statement of Problem and Substantiation for Public Comment This language has long been in the annex of NFPA 13D and it is clear that it is the committee's belief that additional floor area created by certain architectural features are not required to have additional sprinkler coverage. As this language is in the annex and not in the enforceable body of the standard, this intent is not consistently applied to such architectural features. Moving this language to the body of the standard would make this longstanding intent of the committee enforceable and clear that additional sprinkler protection is not required in these small areas. As these areas are not required to be included in the hydraulic design area of the systems, these areas are distinct from shadow areas. This language has been included in the body of NFPA 13R and it is not the intent that the requirements of NFPA 13D be more stringent in regards to this issue. Related Public Comments for This Document Related Comment Public Comment No. 31-NFPA 13D-2014 [Section No. A.8.2.5] Related Item First Revision No. 15-NFPA 13D-2013 [Section No. A.8.2.5] Relationship Submitter Information Verification Submitter Full Name: Roland Asp Organization: National Fire Sprinkler Association Affilliation: NFSA E&S Committee Street Address: City: State: Zip: Submittal Date: Fri May 16 15:10:09 EDT 2014 Committee Statement

16 6 of 52 9/22/2014 9:20 AM Committee Rejected but see related SR Action: Resolution: SR-6-NFPA 13D-2014 Statement: This language has long been in the annex of NFPA 13D and it is clear that additional floor area created by certain architectural features are not required to have additional sprinkler coverage. As this language is in the annex and not in the enforceable body of the standard, this intent is not consistently applied to such architectural features. Moving this language to the body of the standard will make it clear that additional sprinkler protection is not required in these small areas. As these areas are not required to be included in the hydraulic design area of the systems, these areas are distinct from shadow areas

17 7 of 52 9/22/2014 9:20 AM Public Comment No. 25-NFPA 13D-2014 [ New Section after ] In closets and compartments enclosed by walls and a door, including those housing mechanical equipment, that are smaller than 400 ft3 (11.3 m3), pendent, upright and sidewall residential sprinklers shall be permitted to be installed within 18 inches of the ceiling to avoid obstructions near the ceiling. Additional Proposed Changes File Name Description Approved Computer_Modeling_of_Closet.pdf Computer modeling of closet with residential sprinklers Statement of Problem and Substantiation for Public Comment Small closets, especially those housing mechanical equipment, frequently contain obstructions that make it difficult to place sprinklers within 12 inches of the ceiling. Allowing residential sprinklers to be located further down would allow adequate sprinkler protection of these small closets while avoiding ceiling level obstructions such as ducts and pipes. Based upon CFAST Computer Fire Model, an analysis was performed comparing the performance of sprinklers located 6 inches down from a ceiling in a small room to the performance of sprinklers 18 inches down from the ceiling in an even smaller closet. Based upon this analysis it appears that residential sprinklers 18 inches down from the ceiling in a closet up to 400 ft3 react to a fire at least as quickly as residential sprinklers 6 inches down from a ceiling in a small room. Using equivalency concepts, residential sprinklers could be allowed to be installed within 18 inches of the ceiling in small closets. This analysis is included in this public comment. Related Item First Correlating Revision No. 1-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Roland Asp Organization: National Fire Sprinkler Association Affilliation: NFSA E&S Committee Street Address: City: State: Zip: Submittal Date: Wed May 14 09:50:28 EDT 2014 Committee Statement Committee Rejected but see related SR Action: Resolution: SR-5-NFPA 13D-2014 Statement: Small closets, especially those housing mechanical equipment, frequently contain obstructions that make it difficult to place sprinklers within 12 inches of the ceiling. Allowing residential sprinklers to be located further down would allow adequate sprinkler protection of these small closets while avoiding ceiling level obstructions such as ducts and pipes. Based upon CFAST Computer Fire Model, an analysis was performed comparing the performance of sprinklers located 6 inches down from a ceiling in a small room to the performance of sprinklers 18 inches down from the ceiling in an even smaller closet. Based upon this analysis it appears that residential sprinklers 18 inches down from the ceiling in a closet up to 400 ft3 react to a fire at least as quickly as residential sprinklers 6 inches down from a ceiling in a small room. Using equivalency concepts, residential sprinklers could be allowed to be installed within 18 inches of the ceiling in small closets.

18 Computer Modeling of Closet with Residential Sprinkler 18 Inches from Ceiling This analysis uses the CFAST Computer Fire Model to compare the performance of sprinklers 6 inches down from the ceiling in a small room to the performance of sprinklers 18 inches down from the ceiling in an even smaller closet. Baseline Room: 15 ft x 15 ft x 8 ft 3 sprinkler locations (see Figure 1) o Sprinkler 1 4 ft from south and west walls o Sprinkler 2 Centered between east and west walls, 4 ft from south wall o Sprinkler 3 4 inches from south and east walls All sprinklers 6 inches from ceiling All sprinklers RTI = 50 (metric units) Closet: 7 ft x 7 ft x 8 ft (392 ft 3 ) 3 sprinkler locations (see Figure 2) o Sprinkler 1 2 ft from south and west walls o Sprinkler 2 Centered between east and west walls, 2 ft from south wall o Sprinkler 3 4 inches from south and east walls All sprinklers 18 inches down from ceiling All sprinklers RTI = 50 (metric units) Fire: Fairly slow growing fire Center of the room/closet See Figure Figure 1 Baseline Room Figure 2 Closet 392 ft 3

19 Figure 3 Heat Release Rate for Fire (Note that the first 600 seconds are the only important parts of the heat release due to sprinkler activation time) Results The following table compares the activation time of the sprinklers in the small room to that of the sprinklers in the even smaller closet: Sprinkler Activation Time in Small Room (Figure 1) Activation Time in Closet (Figure 2) seconds 500 seconds seconds 500 seconds seconds 500 seconds Conclusions Given this fire location and these three sprinkler locations, it would appear that residential sprinklers 18 inches down from the ceiling in a closet up to 400 ft 3 react to a fire at least as quickly as residential sprinklers 6 inches down from a ceiling in a small room. Using equivalency concepts, residential sprinklers could be allowed to be installed within 18 inches of the ceiling in small closets. Prior to making any final determination, other combinations of fire size, fire location, and sprinkler location should be analyzed in the same manner.

20 Public Comment No. 11-NFPA 13D-2014 [ Section No ] Closets. In all closets and compartments, including those housing mechanical equipment, that are smaller than 400 ft 3 (11.3 m 3 ), a single sprinkler at the highest ceiling space ceiling level shall be sufficient without regard to obstructions or minimum distances to wall. Statement of Problem and Substantiation for Public Comment This change correlates with the language in NFPA 13R. Related Item First Revision No. 26-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Peter Schwab Organization: Wayne Automatic Fire Sprinkler Street Address: City: State: Zip: Submittal Date: Thu Apr 17 13:41:16 EDT 2014 Committee Statement Committee Action: Rejected but see related SR Resolution: SR-5-NFPA 13D-2014 Statement: Small closets, especially those housing mechanical equipment, frequently contain obstructions that make it difficult to place sprinklers within 12 inches of the ceiling. Allowing residential sprinklers to be located further down would allow adequate sprinkler protection of these small closets while avoiding ceiling level obstructions such as ducts and pipes. Based upon CFAST Computer Fire Model, an analysis was performed comparing the performance of sprinklers located 6 inches down from a ceiling in a small room to the performance of sprinklers 18 inches down from the ceiling in an even smaller closet. Based upon this analysis it appears that residential sprinklers 18 inches down from the ceiling in a closet up to 400 ft3 react to a fire at least as quickly as residential sprinklers 6 inches down from a ceiling in a small room. Using equivalency concepts, residential sprinklers could be allowed to be installed within 18 inches of the ceiling in small closets. 8 of 52 9/22/2014 9:20 AM

21 9 of 52 9/22/2014 9:20 AM Public Comment No. 12-NFPA 13D-2014 [ Section No ] Sprinklers shall not be required in clothes closets, linen closets, and pantries that meet all of the following conditions: (1) The area of the space does not exceed 24 ft 2 (2.2 m 2 ). (2) The walls and ceilings are surfaced with noncombustible or limited-combustible materials as defined in NFPA 220. Statement of Problem and Substantiation for Public Comment Editorial. Delete the (3) Related Item First Revision No. 1-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Peter Schwab Organization: Wayne Automatic Fire Sprinkler Street Address: City: State: Zip: Submittal Date: Thu Apr 17 13:44:24 EDT 2014 Committee Statement Committee Action: Accepted Resolution: SR-8-NFPA 13D-2014 Statement: Editorial. Delete the (3)

22 0 of 52 9/22/2014 9:20 AM Public Comment No. 23-NFPA 13D-2014 [ Section No ]

23 1 of 52 9/22/2014 9:20 AM *

24 2 of 52 9/22/2014 9:20 AM Unless the pipe size is in accordance with the prescriptive pipe sizing method of , pipe shall be sized by hydraulic calculations in accordance with the methods described in NFPA 13, with the manufacturer's listed installation instructions, with , or with the following general method for straight-run systems connected to a city water main of at least 4 in. (102 mm) in diameter: The system flow rate shall be established in accordance with Sections 10.1 and 10.2, and it shall be determined that the flow allowed by the water meter meets or exceeds the system demand and that the total demand flow does not exceed the maximum flow allowed by the piping system components. The water pressure in the street shall be determined. Pipe sizes shall be selected. * Pressure loss for a water meter, if any, shall be determined and deducted The pipes shall be sized using one of the following techniques : Table (a) shall be permitted to be used, even where the sprinkler demand flow exceeds the meter's rated continuous flow. Higher pressure losses specified by the manufacturer shall be used in place of those specified in Table (a). Lower pressure losses shall be permitted to be used where supporting data are provided by the meter manufacturer. Pressure loss for elevation shall be deducted as follows: (1) Building height above street (ft) = pressure loss (psi) (2) Building height above street (m) = pressure loss (bar) * Pressure losses from the city main to the inside control valve shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). Pressure loss for piping within the building shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). Pressure loss for valves and fittings shall be deducted as follows: (1) The valves and fittings from the control valve to the farthest sprinkler shall be counted. (2) The equivalent length for each valve and fitting as shown in Table (b), Table (c), or Table (d) or Table (e) shall be determined and the values added to obtain the total equivalent length for each pipe size. (3) The equivalent length for each size shall be multiplied by the pressure loss associated with the pipe material and the values totaled. In multilevel buildings, the steps in (1) through (8) shall be repeated to size piping for each floor. If the remaining pressure is less than the operating pressure established by the testing laboratory for the sprinkler being used, the sprinkler system shall be redesigned. If the remaining pressure is higher than required, smaller piping shall be permitted to be used where justified by calculations. The remaining piping shall be sized the same as the piping up to and including the farthest sprinkler unless smaller pipe sizes are justified by calculations. Table (a) Pressure Losses in psi in Water Meters Meter Size (in.) Flow (gpm) 18 or less * * For SI units, 1 gpm = L/min; 1 in. = 25.4 mm; 1 psi = bar. *Above maximum rated flow of commonly available meters. Table (b) Equivalent Length in Feet of Fittings and Valves for Schedule 40 Steel Pipe Diameter

25 3 of 52 9/22/2014 9:20 AM (in.) 45 Degree Elbow 90 Degree Elbow Long- Radius Elbow Tee or Cross (flow turned 90 degrees) Tee or Cross (flow straight through) Gate Valve Angle Valve Globe Valve Globe Y Pattern Valve Cock Valve Check Valve For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (c) Equivalent Length in Feet of Fittings and Valves for Type K Copper Tube Diameter (in.) 45 Degree Elbow 90 Degree Elbow Long- Radius Elbow Tee or Cross (flow turned 90 degrees) Tee or Cross (flow straight through) Gate Valve Angle Valve Globe Valve Globe Y Pattern Valve Cock Valve Check Valve For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (d) Equivalent Length in Feet of Fittings and Valves for Type L Copper Tube Diameter (in.) 45 Degree Elbow 90 Degree Elbow Long- Radius Elbow Tee or Cross (flow turned 90 degrees) Tee or Cross (flow straight through) Gate Valve Angle Valve Globe Valve Globe Y Pattern Valve Cock Valve Check Valve For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (e) Equivalent Length in Feet of Fittings and Valves for Type M Copper Tube Diameter (in.) 45 Degree Elbow 90 Degree Elbow Long- Radius Elbow Tee or Cross (flow turned 90 degrees) Tee or Cross (flow straight through) Gate Valve Angle Valve Globe Valve Globe Y Pattern Valve Cock Valve Check Valve For SI units, 1 in. = 25.4 mm; 1 ft = m. (1) The simplified calculation method of , which can only be used for connections to a city water main of at least 4 inches (102mm) in diameter. (2) The prescritive pipe sizing method of (3) The hydraulic calculation procedure for NFPA 13. (4) The manufacturers listed intallation instructions. Statement of Problem and Substantiation for Public Comment Section , as written is confusing and not "user friendly". This public comment seeks to simplify and clarify the acceptable methods for sizing sprinkler pipes for NFPA 13D systems. This comment's does not change the existing requirements of this section, but instead changes the requirements from paragraph form to a list form for ease of interpretation. The 12 step general method originally included in section has been retained but renumbered as section Related Public Comments for This Document Related Comment Public Comment No. 19-NFPA 13D-2014 [Section No ] Related Item First Revision No. 13-NFPA 13D-2013 [Section No ] Relationship Submitter Information Verification Submitter Full Name: Roland Asp Organization: National Fire Sprinkler Association Affilliation: NFSA E&S Committee Street Address: City:

26 4 of 52 9/22/2014 9:20 AM State: Zip: Submittal Date: Mon May 12 15:06:08 EDT 2014 Committee Statement Committee Accepted Action: Resolution: SR-9-NFPA 13D-2014 Statement: Section , as written is confusing and not "user friendly". This revision seeks to simplify and clarify the acceptable methods for sizing sprinkler pipes for NFPA 13D systems. This comment's does not change the existing requirements of this section, but instead changes the requirements from paragraph form to a list form for ease of interpretation. The 12 step general method originally included in section has been retained but renumbered as section

27 5 of 52 9/22/2014 9:20 AM Public Comment No. 19-NFPA 13D-2014 [ Section No ]

28 6 of 52 9/22/2014 9:20 AM Smaller pipe sizes than those determined by shall be permitted where justified by calculations for systems connected to city water mains of at least 4 in. (102 mm) in diameter. * General Pipe Sizing Method The following is the general pipe sizing method for straight-run systems connected to a city water main of at least 4 in. (102 mm) in diameter as per (1):

29 7 of 52 9/22/2014 9:20 AM (1) The system flow rate shall be established in accordance with Sections 10.1 and 10.2, and it shall be determined that the flow allowed by the water meter meets or exceeds the system demand and that the total demand flow does not exceed the maximum flow allowed by the piping system components. (2) The water pressure in the street shall be determined. (3) Pipe sizes shall be selected. (4) *Pressure loss for a water meter, if any, shall be determined and deducted using one of the following: (5) Table (a) shall be permitted to be used, even where the sprinkler demand flow exceeds the meter's rated continuous flow. (6) Higher pressure losses specified by the manufacturer shall be used in place of those specified in Table (a). (7) Lower pressure losses shall be permitted to be used where supporting data are provided by the meter manufacturer. (8) Pressure loss for elevation shall be deducted as follows: (9) Building height above street (ft) = pressure loss (psi) (10) Building height above street (m) = pressure loss (bar) (11) *Pressure losses from the city main to the inside control valve shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). (12) Pressure loss for piping within the building shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). (13) Pressure loss for valves and fittings shall be deducted as follows: (14) The valves and fittings from the control valve to the farthest sprinkler shall be counted. (15) The equivalent length for each valve and fitting as shown in Table (b), Table (c), or Table (d) or Table (e) shall be determined and the values added to obtain the total equivalent length for each pipe size. (16) The equivalent length for each size shall be multiplied by the pressure loss associated with the pipe material and the values totaled. (17) In multilevel buildings, the steps in (1) through (8) shall be repeated to size piping for each floor. (18) If the remaining pressure is less than the operating pressure established by the testing laboratory for the sprinkler being used, the sprinkler system shall be redesigned. (19) If the remaining pressure is higher than required, smaller piping shall be permitted to be used where justified by calculations. (20) The remaining piping shall be sized the same as the piping up to and including the farthest sprinkler unless smaller pipe sizes are justified by calculations. Table (a) Pressure Losses in psi in Water Meters Meter Size (in.) Flow (gpm) 18 or less * * For SI units, 1 gpm = L/min; 1 in. = 25.4 mm; 1 psi = bar.

30 8 of 52 9/22/2014 9:20 AM *Above maximum rated flow of commonly available meters. Table (b) Equivalent Length in Feet of Fittings and Valves for Schedule 40 Steel Pipe Diameter (in.) 45 Degree Elbow 90 Degree Elbow Long- Radius Elbow Tee or Cross (flow turned 90 degrees) Tee or Cross (flow straight through) Gate Valve Angle Valve Globe Valve Globe Y Pattern Valve Cock Valve Check Valve For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (c) Equivalent Length in Feet of Fittings and Valves for Type K Copper Tube Diameter (in.) 45 Degree Elbow 90 Degree Elbow Long-. Radius Elbow Tee or Cross (flow turned 90 degrees) Tee or Cross (flow straight through) Gate Valve Angle Valve Globe Valve Globe Y Pattern Valve Cock Valve Check Valve For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (d) Equivalent Length in Feet of Fittings and Valves for Type L Copper Tube Diameter (in.) 45 Degree Elbow 90 Degree Elbow Long- Radius Elbow Tee or Cross (flow turned 90 degrees) Tee or Cross (flow straight through) Gate Valve Angle Valve Globe Valve Globe Y Pattern Valve Cock Valve Check Valve For SI units, 1 in. = 25.4 mm; 1 ft = m. Table (e) Equivalent Length in Feet of Fittings and Valves for Type M Copper Tube Long- Tee or Tee or Gate Globe Cock

31 9 of 52 9/22/2014 9:20 AM Diameter (in.) Degree Elbow Degree Elbow Radius Elbow Cross (flow turned 90 degrees) Cross (flow straight through) Valve Angle Valve Globe Valve Y Pattern Valve Valve Check Valve For SI units, 1 in. = 25.4 mm; 1 ft = m. Statement of Problem and Substantiation for Public Comment The general method of pipe sizing has been moved from section to to correlate with Public Comment No. 20. The wording and method itself remains unchanged. Related Public Comments for This Document Related Comment Public Comment No. 21-NFPA 13D-2014 [Section No. A ] Public Comment No. 23-NFPA 13D-2014 [Section No ] Related Item First Revision No. 13-NFPA 13D-2013 [Section No ] Relationship Submitter Information Verification Submitter Full Name: Roland Asp Organization: National Fire Sprinkler Association Affilliation: NFSA E&S Committee Street Address: City: State: Zip: Submittal Date: Mon May 12 08:31:25 EDT 2014 Committee Statement Committee Accepted Action: Resolution: SR-15-NFPA 13D-2014 Statement: The general method of pipe sizing has been moved from section to to correlate with SR-9. The wording and method itself remains unchanged.

32 0 of 52 9/22/2014 9:20 AM Public Comment No. 24-NFPA 13D-2014 [ Section No ] Any sprinkler that is operated, damaged, corroded, covered with foreign materials, or showing signs of leakage shall be replaced with a new listed sprinkler having the same performance characteristics as the original equipment * Where replacing residential sprinklers manufactured prior to 2003 and that are no longer available from the manufacturer and are installed using a design density less than 0.05 gpm/ft 2 (204 mm/min), a residential sprinkler with an equivalent K-factor (± 5%) shall be permitted to be used provided the currently listed coverage area for the replacement sprinkler is not exceeded. Statement of Problem and Substantiation for Public Comment It is preferred to replace existing sprinklers with the same model when it is available so that the systems continue to operate as it was designed. This proposal was developed by the UL/FM/NFSA Standards Review Committee. Related Item First Revision No. 23-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Victoria Valentine Organization: National Fire Sprinkler Assoc Affilliation: UL/FM/NFSA Standards Review Committee Street Address: City: State: Zip: Submittal Date: Wed May 14 09:42:39 EDT 2014 Committee Statement Committee Rejected but see related SR Action: Resolution: SR-10-NFPA 13D-2014 Statement: It is preferred to replace existing sprinklers with the same model when it is available so that the systems continue to operate as it was designed.

33 1 of 52 9/22/2014 9:20 AM Public Comment No. 1-NFPA 13D-2014 [ Section No ] * Where replacing residential sprinklers manufactured prior to 2003 and installed using a design density less than 0.05 gpm/ft 2 (204 mm/min), a residential sprinkler with an equivalent K-factor (± 5%) shall be permitted to be used provided the currently listed coverage area for the replacement sprinkler is not exceeded require replacement and the same model of residential sprinkler is no longer available, replacement residential sprinklers shall either have a consistent hydraulic demand with the original residential sprinklers or calculations shall be provided to demonstrate that system supply meets the demand of the replacement sprinklers. Statement of Problem and Substantiation for Public Comment The proposed language would allow the use of replacement sprinklers with hydraulic demands that may exceed the available system supply. If an equivalent replacement sprinkler is not available, then calculations should be performed that prove the system can support the replacement residential sprinklers. Related Item First Revision No. 23-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Mark Fessenden Organization: Tyco Fire Protection Products Street Address: City: State: Zip: Submittal Date: Tue Mar 11 10:56:57 EDT 2014 Committee Statement Committee Action: Resolution: Rejected Requiring recalculation to new flows and pressures would be burdensome and may in some instances would require systems to be replace.

34 2 of 52 9/22/2014 9:20 AM Public Comment No. 13-NFPA 13D-2014 [ Section No ] * Where replacing residential sprinklers manufactured prior to 2003 and, installed using a design density less than 0.05 gpm/ft 2 (204 mm/min), a and that are no longer available from the manufacturer, a residential sprinkler with an equivalent K-factor (± 5%) shall be permitted to be used provided the currently listed coverage area for the replacement sprinkler is not exceeded. Statement of Problem and Substantiation for Public Comment The first option should be to use the manufacturer's replacement sprinkler when it is available. Related Item First Revision No. 23-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Peter Schwab Organization: Wayne Automatic Fire Sprinkler Street Address: City: State: Zip: Submittal Date: Thu Apr 17 13:48:45 EDT 2014 Committee Statement Committee Rejected but see related SR Action: Resolution: SR-10-NFPA 13D-2014 Statement: It is preferred to replace existing sprinklers with the same model when it is available so that the systems continue to operate as it was designed.

35 3 of 52 9/22/2014 9:20 AM Public Comment No. 17-NFPA 13D-2014 [ Section No ] * Where replacing residential sprinklers manufactured prior to 2003 and installed using a design density less than 0.05 gpm/ft 2 (204 mm/min), and that are no longer available from the manufacturer, a residential sprinkler with an equivalent K-factor (± 5%) shall be permitted to be used provided the currently listed coverage area for the replacement sprinkler is not exceeded. Statement of Problem and Substantiation for Public Comment This section would allow residential sprinklers installed to a design density of less then 0.05 gpm/ft2 to be replaced with a replacement sprinkler with an equivalent k-factor. As stated in A , the flow and pressure available to the replacement sprinkler might be less than its current flow and pressure requirement. If the sprinkler to be replaced is still available from the manufacturer, that sprinkler should be used as the replacement to ensure, where possible, that the original criteria continues to be met. Related Item First Revision No. 23-NFPA 13D-2013 [Section No ] Submitter Information Verification Submitter Full Name: Roland Asp Organization: National Fire Sprinkler Association Affilliation: NFSA E&S Committee Street Address: City: State: Zip: Submittal Date: Thu May 01 10:20:28 EDT 2014 Committee Statement Committee Rejected but see related SR Action: Resolution: SR-10-NFPA 13D-2014 Statement: It is preferred to replace existing sprinklers with the same model when it is available so that the systems continue to operate as it was designed.

Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group

Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group of 36 9/22/2014 9:37 AM Second Revision No. 14-NFPA 13D-2014 [ Global Comment ] Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group Supplemental

More information

1 of /3/ :03 PM. Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ]

1 of /3/ :03 PM. Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ] 1 of 129 11/3/2016 12:03 PM Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ] 2 of 129 11/3/2016 12:03 PM American Society of Mechanical Engineers Chapter 2 Referenced Publications 2.1 General. The documents

More information

Public Comment No. 20-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 20-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item of 27 9/2/2014 9:27 AM Public Comment No. 20-NFPA 24-2014 [ Section No. 2.3.2 ] 2.3.2 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM

More information

Public Comment No. 2-NFPA [ Section No ]

Public Comment No. 2-NFPA [ Section No ] Public Comment No. 2-NFPA 16-2013 [ Section No. 3.3.6 ] 3.3.6* Foam-Water Sprinkler System. A piping network connected to a source of foam concentrate and to a water supply. The piping network is equipped

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification Public Comment No. 2-NFPA 73-2014 [ Section No. 4.1.3 ] 4.1.3 Unused Openings. 4.1.3.1 Unused openings, other than those intended for the operation of equipment, those intended for mounting purposes, or

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Residential Sprinkler

More information

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings Reprinted with permission from NFPA 13D Installation of Sprinkler Systems in One- and two-family Dwellings and Manufactured

More information

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 4-NFPA 214-2013 [ Section No. 4.2 ] 4.2 * Fire Risk Analysis. A fire risk analysis shall be conducted. The following are some of the factors that shall be considered in determining the

More information

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item Public Comment No. 23-NFPA 96-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM E84, Standard Test Method

More information

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

Committee Input No. 28-NFPA 13R-2013 [ Global Input ] Page 1 of 6 Committee Input No. 28-NFPA 13R-2013 [ Global Input ] 6.2.2 Outside Dwelling Units. 6.2.2.1 All sprinklers used outside of the dwelling units shall be in accordance with 6.2.2 7.2 and 7.3.

More information

Public Comment No. 22-NFPA [ New Section after 1.4 ] Statement of Problem and Substantiation for Public Comment

Public Comment No. 22-NFPA [ New Section after 1.4 ] Statement of Problem and Substantiation for Public Comment of 25 5/14/2015 2:32 PM Public Comment No. 22-NFPA 14-2014 [ New Section after 1.4 ] A.1.4 A.1.4 It is the intent of the Commi ee to recognize that future edi ons of this standard are a further refinement

More information

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement Second Revision No. 20-NFPA 14-2015 [ Section No. 1.4 ] 1.4* Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength,

More information

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur. First Revision No. 1-NFPA 501-2015 [ Section No. 5.3.1.3 ] 5.3.1.3 The following conditions shall be met when an interior finish material is tested using the test protocol of NFPA 286, Standard Methods

More information

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

WORKING DRAFT OF COMMITTEE MEETING OUTPUT WORKING DRAFT OF COMMITTEE MEETING OUTPUT CONTENT NOT FINAL SUBJECT TO REVISION PRIOR TO LETTER BALLOT AND PUBLICATION OF SECOND DRAFT REPORT Document: NFPA 221 Revision Cycle: A2014 Meeting Date: 5/20/2013

More information

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 4-NFPA 496-2014 [ Section No. 5.2.2 ] 5.2.2 Where When the enclosure has been opened or if the protective gas supply has failed to maintain the required positive pressure, the enclosure

More information

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document 1 of 19 10/21/2015 1:20 PM Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three ASME International, Two

More information

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Standpipes Elena

More information

Sprinkler Permit Applications

Sprinkler Permit Applications REQUIREMENTS FOR NFPA 13 SYSTEM Building Inspections Sprinkler Permit Applications A complete application for a Sprinkler Permit will comply with the requirements of Chapter 8 of NFPA 13. Hydraulic calculations

More information

Public Input No. 88-NFPA [ New Section after ] Statement of Problem and Substantiation for Public Input

Public Input No. 88-NFPA [ New Section after ] Statement of Problem and Substantiation for Public Input of 201 1/13/2014 12:51 PM Public Input No. 88-NFPA 20-2013 [ New Section after 3.3.38.10 ] Add New Defination 3.3.28.11 Multiple Stage Multiple Port Pump. A single driver pump with multiple impellers operating

More information

Remove the "Exception" text to be consistent with direction provided in the MOS.

Remove the Exception text to be consistent with direction provided in the MOS. of 37 1/11/2017 7:38 AM Public Input No. 9-NFPA 88A-2015 [ Global Input ] Remove the "Exception" text to be consistent with direction provided in the MOS. The current language in 88A has numerous section

More information

Throughout standard remove references to the following and replace with the following:

Throughout standard remove references to the following and replace with the following: of 35 12/3/2015 7:13 AM Public Input No. 1-NFPA 90A-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) ANSI/UL and replace with UL. (2) ANSI/ASHRAE

More information

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input Public Input No. 16-NFPA 211-2014 [ Section No. 2.3.1 ] 2.3.1 ASHRAE Publications. ASHRAE, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. ASHRAE Handbook: HVAC Systems and Equipment, 2008 2012.

More information

Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12.

Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12. 2/18/2016 National Fire Protection Association Report Committee Input No. 70 NFPA 54 2015 [ Section No. 12.5 ] This was a First Revision that failed ballot. 12.5 Type of Venting System to Be Used. 12.5.1

More information

Public Comment No. 2-NFPA [ Section No ]

Public Comment No. 2-NFPA [ Section No ] Page 1 of 13 Public Comment No. 2-NFPA 703-2013 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, P.O. Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. ASTM D 2898, Standard

More information

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM 1 of 14 6/22/2016 3:15 PM Second Revision No. 1-NFPA 17A-2016 [ Section No. 4.3.3 ] 4.3.3 All discharge nozzles shall be provided with caps or other suitable devices to prevent the entrance of grease vapors,

More information

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements 1. IRC Sections R313 and R314, insert two new sections as follows: R313 FIRE SPRINKLER SYSTEM FOR TOWNHOUSES R313.1 Required Installation. An automatic residential fire sprinkler system shall be installed

More information

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ] 8 of 93 11/6/2015 7:41 AM Public Input No. 52-NFPA 30-2015 [ Section No. 21.2 [Excluding any Sub-Sections] ] For the purpose of this chapter, the term in this section shall have the definitions given.

More information

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ]

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ] of 46 11/6/2015 9:21 AM First Revision No. 208-NFPA 30-2015 [ Section No. 9.3.3.1 ] 9.3.3.1 Storage of liquids shall not physically obstruct a means of egress. Submittal Date: Wed Sep 09 18:24:20 EDT 2015

More information

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. 9/20/2016 2:27 PM Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical

More information

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO Item No. Subject 13-6-1 Call to Order (8:00 A.M) 13-6-2 Roll Call 13-6-3 Approval

More information

FIRE SPRINKLER SYSTEMS POLICY

FIRE SPRINKLER SYSTEMS POLICY FIRE SPRINKLER SYSTEMS POLICY Revised 1/1/17 DESIGN AND SUBMITTAL REQUIREMENTS All new and existing fire sprinkler systems within the jurisdiction of the City Fire Department shall meet all of the applicable

More information

Page 1 of 15 Second Revision No. 8-NFPA 82-2013 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 13, Standard for the Installation

More information

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages.

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages. of 123 6/10/2014 9:07 AM First Revision No. 117-NFPA 14-2014 [ Global Input ] 7.3.2.7.5 The distances in 7.3.2.2 shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement of 1 9/22/2014 1:38 PM Second Revision No. 104-NFPA 72-2014 [ Section No. 3.3.3 ] 3.3.3 Accessible, Readily (Readily Accessible). Capable of being reached quickly for operation, renewal, or inspections

More information

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Residential Sprinkler Systems

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Residential Sprinkler Systems National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Residential

More information

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) Page:1 of 5 Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) General Description The Model HF-RES Residential Flush Horizontal Side-Wall

More information

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification Second Revision No. 2011-NFPA 101-2016 [ Section No. 14.2.2.2.4 ] 14.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked to prevent unwanted entry

More information

12/21/2015 National Fire Protection Association Report

12/21/2015 National Fire Protection Association Report http://submittals.nfpa.org/terraviewweb/viewerpage.jsp?id=232 2012.ditamap&toc=false&draft=true 1/9 Public Comment No. 1 NFPA 232 2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents

More information

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010 New Zealand Standard Fire sprinkler systems for houses Superseding NZS 4517:2002 NZS 4517:2010 NZS 4517:2010 COMMITTEE REPRESENTATION This Standard was prepared under the supervision of the P 4517 Committee,

More information

Page 1 of 198 Public Input No. 88-NFPA 20-2013 [ New Section after 3.3.38.10 ] Add New Defination 3.3.28.11 Multiple Stage Multiple Port Pump. A single driver pump with multiple impellers operating in

More information

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Helicopter Facilities

More information

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.7.13 Control Number: A.0 Effective Date: 11/15/11 TITLE:

More information

FIRE SPRINKLER SYSTEMS POLICY

FIRE SPRINKLER SYSTEMS POLICY FIRE SPRINKLER SYSTEMS POLICY VERSION 1.012/2015 FIRE SPRINKLER SYSTEMS Design and Submittal requirements All new and existing fire sprinkler systems within the jurisdiction of the City of San Mateo Fire

More information

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification of 4 9/23/2016 10:20 AM Second Revision No. 6501-NFPA 5000-2016 [ Section No. 17.2.2.2.4 ] 17.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked

More information

"Spray area" is the term that is used throughout the document. This change is for consistency.

Spray area is the term that is used throughout the document. This change is for consistency. of 78 5/30/2014 2:08 PM Public Comment No. 39-NFPA 33-2013 [ Global Input ] For Chapter 18, replace "spray paint area" with "spray area". "Spray area" is the term that is used throughout the document.

More information

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, 2014 9:00 AM - 5:00 PM EST Web/Teleconference Meeting 1. Welcome. George Seuss, Chair 2. Introductions and Update

More information

MEMORANDUM. Technical Committee on Board and Care Facilities. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

MEMORANDUM. Technical Committee on Board and Care Facilities. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Board and Care Facilities

More information

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD Installation of Residential Fire Sprinkler Systems STANDARD #C-002 EFFECTIVE 03-19-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain

More information

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS Fire Protection Systems includes the following: Alternate Fire Suppression Systems Atrium Fire Protection Systems Automatic Fire Sprinkler

More information

What You Need to Know about Residential Sprinkler Design

What You Need to Know about Residential Sprinkler Design What You Need to Know about Residential Sprinkler Design Melisa Rodriguez, P.E., NICET IV Design Services Supervisor, Fire Safety melisa.rodriguez@uponor.com www.uponor-usa.com The Residential Sprinkler

More information

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 SPRINKLER SHOP DRAWINGS 2007 NFPA 13 and 2007 NFPA 24 Project: Listed items require sprinkler

More information

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA Page of 5. DESCRIPTION Viking EC/QREC Ordinary Hazard ELO Fusible Element Sprinkler VK535 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying

More information

Committee on NFPA 51A

Committee on NFPA 51A Committee on M E M O R A N D U M TO: FROM: NFPA Technical Committee on Industrial and Medical Gases Patti Mucci, Administrative Assistant DATE: May 6, 2010 SUBJECT: ROC Letter Ballot The ROC letter ballot

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE Developed by the Midwestern Regional Work Group CONTENTS Item 15 Limited area sprinkler systems Item 20 Scope of IFC Ch 7 Item 21 Fire-resistance-rated

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

Center for Life Safety Education

Center for Life Safety Education Center for Life Safety Education Fire Sprinklers 101 Introduction, Building Codes, and Water Supplies Reprinted with permission from NFPA 13, Installation of Sprinkler Systems, Copyright 2007, National

More information

Second Revision No. 3-NFPA [ Section No. 2.3 ]

Second Revision No. 3-NFPA [ Section No. 2.3 ] Second Revision No. 3-NFPA 804-2014 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990. ASME Boiler

More information

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description TYCO Series EC-11 and EC-14 Extended

More information

What Builders Need to Know about Residential Sprinkler Design

What Builders Need to Know about Residential Sprinkler Design What Builders Need to Know about Residential Sprinkler Design Melisa Rodriguez, P.E., NICET IV Design Services Supervisor, Fire Safety melisa.rodriguez@uponor.com www.uponor-usa.com Agenda Brief history

More information

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM of 25 7/30/2015 1:35 PM First Revision No. 49-NFPA 17A-2015 [ Detail ] Make the following change to 5.2.1.10.2: 5.2.1.10.2* The manual actuation device shall clearly identify the hazard protected and provide

More information

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for

More information

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description Page:1 of 5 SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description The Model ZN-RES Residential Flush Pendent

More information

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] 1.3 Application. 1.3.1 This standard shall apply to all systems for the movement of environmental air in structures that serve the following, except

More information

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA September 5, 2008 Sprinkler 147u 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Sprinkler VK457 is a small highsensitivity solder link and lever residential sprinkler designed for installation

More information

Second Revision No. 2-NFPA [ Section No ]

Second Revision No. 2-NFPA [ Section No ] Page 1 of 8 Second Revision No. 2-NFPA 410-2014 [ Section No. 10.2 ] 10.2* Fire Extinguishers. In addition to extinguishers required by NFPA 409, extinguishers shall be provided for aircraft maintenance

More information

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17 The following list contains a summary of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. 1.1.1.1 (B), (C), & (D)

More information

NFPA Edition Update

NFPA Edition Update NFPA 13 2013 Edition Update Session Agenda A2012 Code Cycle NFPA 13 Code Development Changes to NFPA 13 (NFPA 24) What Didn t Happen Next Steps 2 A2012 Code Cycle 800+ Proposal 500+ Comments TCC Meeting

More information

Public Comment No. 32-NFPA 90A-2016 [ Section No ] Statement of Problem and Substantiation for Public Comment

Public Comment No. 32-NFPA 90A-2016 [ Section No ] Statement of Problem and Substantiation for Public Comment of 53 11/9/2016 9:07 AM Public Comment No. 32-NFPA 90A-2016 [ Section No. 2.3.2 ] 2.3.2 ASTM International Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA

More information

SENJU SPRINKLER CO., LTD.

SENJU SPRINKLER CO., LTD. Page:1 of 8 SENJU SPRINKLER CO., LTD. Residential, Pendent Sprinkler Model FR-RES K-Factor: 4.9 SIN: SS4451 GENERAL DESCRIPTION The Model FR-RES Residential Pendent and Recessed Pendent Sprinklers are

More information

SAF-BCF SECOND REVISIONS WITH STATEMENTS

SAF-BCF SECOND REVISIONS WITH STATEMENTS Page 196 of 331 32.2.1.3 ] Second Revision No. 153-NFPA 101-2013 [ New Section after 32.2.1.4 Multiple-Level Buildings. For purposes of applying requirements of this chapter that utilize the term level

More information

Page 1 of 19 Committee Input No. 14-NFPA 33-2013 [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new

More information

2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14

2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14 The following list contains a summary of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. PIPING Various Brass REVISED

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Sprinkler System

More information

PLAN REVIEW CHECKLIST

PLAN REVIEW CHECKLIST PLAN REVIEW CHECKLIST Date Documents Submitted: Log No.: File No.: Property Information Building Name: Building Address: Owner s Name: Owner s Address: Owner s Phone: Fax: E-mail: System Designer/Contractor

More information

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM 1 of 11 1/18/2016 5:43 PM First Revision No. 2-NFPA 51-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) CGA C-7 Guide to Precautionary Labelling

More information

Public Input No. 107-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 107-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification of 123 7/30/2015 1:48 PM Public Input No. 107-NFPA 96-2014 [ Section No. 1.3.2 ] 1.3.2 The authority having jurisdiction shall determine compliance with this standard and authorize equivalent deviations

More information

Public Comment No. 1-NFPA [ Section No ]

Public Comment No. 1-NFPA [ Section No ] Page 1 of 7 Public Comment No. 1-NFPA 556-2014 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA, 19428-2959. ASTM D2859, Standard

More information

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16 (42,7 mm) CROSS SECTION Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description Extended Coverage and Pendent Sprinklers

More information

First Revision No. 1-NFPA [ Chapter 2 ]

First Revision No. 1-NFPA [ Chapter 2 ] First Revision No. 1-NFPA 499-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this recommended practice

More information

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems Residential Fire Protection Presentation Zurn Pex, Inc PEX Plumbing, Radiant Heating and Residential Fire Protection Systems Matt Lawrence BDM-North Central Region 1 Presentation Outline I. IRC Mandate

More information

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

Change all instances of flame resistant (hypobaric) to Limited-Combustible (material) in all instances in the document. 1 of 9 10/21/2015 1:22 PM First Revision No. 3-NFPA 99B-2015 [ Global Input ] Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

More information

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM 1 of 213 10/20/2016 11:02 AM Committee Input No. 2505-NFPA 72-2016 [ Global Input ] Change the term visible to visual where appropriate Submitter Information Verification Submitter Full Name: SIG-NAS Organization:

More information

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region The following sections, paragraphs, and sentences of the 2015 International Existing

More information

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD INSTALLATION OF COMMERCIAL FIRE SPRINKLER SYSTEMS STANDARD #C-001 EFFECTIVE 03-25-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain

More information

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input Public Input No. 4-NFPA 111-2016 [ Section No. 1.1.4.1 ] 1.1.4.1 * This standard shall not cover the following: (1) Application of the SEPSS (2) Distribution wiring (3) Systems having total outputs less

More information

26 of 128 9/23/2014 9:25 AM

26 of 128 9/23/2014 9:25 AM 26 of 128 9/23/2014 9:25 AM Second Revision No. 105-NFPA 72-2014 [ Global Comment ] Revise the Annex F figures that include a smoke detector symbol (hexagon with a whisp of smoke) so that the new smoke

More information

DESIGN & CONSTRUCTION GUIDELINES

DESIGN & CONSTRUCTION GUIDELINES ADMINISTRATIVE SERVICES 4202 E. FOWLER AVENUE, FPC110 PHONE: (813) 974-2625 FACILITIES PLANNING & CONSTRUCTION TAMPA, FLORIDA 33620-7550 WEBSITE: USF.EDU/FPC DESIGN & CONSTRUCTION GUIDELINES DIVISION 21

More information

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input of 280 2/6/2015 12:06 PM Public Input No. 1-NFPA 58-2013 [ Global Input ] NOTE: This public input originates from Tentative Interim Amendment 58-14-1 (TIA 1079) issued by the Standards Council on August

More information

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] 4.3.11.5.5 Materials within a raised floor plenum exposed to the airflow shall be (a) noncombustible or (b) exhibit a maximum flame spread index of 25

More information

MEMORANDUM. Technical Committee on Alternative Approaches to Life Safety. NFPA 101A First Draft Technical Committee FINAL Ballot Results (A2018)

MEMORANDUM. Technical Committee on Alternative Approaches to Life Safety. NFPA 101A First Draft Technical Committee FINAL Ballot Results (A2018) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Alternative Approaches to

More information

MONTECITO FIRE PROTECTION DISTRICT

MONTECITO FIRE PROTECTION DISTRICT Section 5a MONTECITO FIRE PROTECTION DISTRICT FIRE PROTECTION PLAN Residential Automatic Fire Sprinkler System Installations I Automatic Fire Sprinkler System Standards 1. Definition and Standard: An automatic

More information

Data Sheet 4.24 Issue F

Data Sheet 4.24 Issue F General Description The model RD207 residential flat concealed sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The cover plate assembly

More information

Page 1 of 190 Public Input No. 22-NFPA 55-2013 [ Global Input ] Throughout the document, delete ANSI from ANSI/ASME B31.3. Current Text: (multiple locations) ANSI/ASME B31.3 (found in Subsections: 2.3.2

More information

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement Second Revision No. 1-NFPA 90A-2016 [ Section No. 2.3.2 ] 2.3.2 ASTM International Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM C411, Standard

More information

Fire Sprinkler System Design and Installation Requirements

Fire Sprinkler System Design and Installation Requirements Fire Sprinkler System Design and Installation Requirements The Park City Fire Service District (PCFD) and Park City Municipal Corporation (PCMC) have made the following amendments to the State of Utah

More information

Subject: BSR Uniform Mechanical Code, 2015 Edition: Appeal on Proposal #333

Subject: BSR Uniform Mechanical Code, 2015 Edition: Appeal on Proposal #333 Paul Cabot Administrator National Fuel Gas Ms. Gabriella Davis Recording Secretary, IAPMO Standards Council International Association of Plumbing and Mechanical Officials (IAPMO) IAPMO Group World Headquarters

More information