SOUTHVIEW MEDICAL CENTER
|
|
- Timothy Gardner
- 5 years ago
- Views:
Transcription
1 PROJECT TITLE: SOUTHVIEW MEDICAL CENTER ENTRANCE VESTIBULE 1997 Miamisburg Centerville Rd. Dayton, Ohio DRAWING INDEX: STRUCTURAL ARCHITECTURAL JUNE 26, 2014 Bulletin #1 - September 12, 2014 AREA OF WORK PROJECT TEAM: CODE AND STANDARDS: PINNACLE ARCHITECTS PROJECT ARCHITECTS 210 N. SAINT CLAIR STREET DAYTON, OHIO HEAPY ENGINEERING MECHANICAL ELECTRICAL CONSULTANTS 1400 WEST DOROTHY LANE DAYTON, OHIO SHELL & MEYER ASSOCIATES STRUCTURAL ENGINEERS 2202 S. PATTERSON BLVD. DAYTON, OHIO THE DRAWINGS HAVE BEEN REVIEWED FOR CONFORMANCE TO: * THE OHIO BUILDING CODE, INCLUDING THE MECHANICAL, ELECTRICAL AND PLUMBING CODES, 2013 EDITION. * N.F.P.A LIFE SAFETY CODE, 2000 EDITION. 2. CODE COMPLIANCE PLANS INDICATE RATED WALL CONSTRUCTION, FIRE SEPARATION AND SMOKE PARTITIONS IN CONFORMANCE WITH APPLICABLE CODES FOR NEW AND REMODELED CONSTRUCTION. 3. EXISTING CONSTRUCTION IS SHOWN TO DEMONSTRATE INTEGRATION OF THE NEW WORK WITH THE EXISTING SYSTEM OF FIRE AND SMOKE BARRIERS. THE EXISTING CONSTRUCTION SHOWN IS PRESUMED TO BE IN COMPLIANCE WITH APPLICABLE CODES. CODE DATA: USE GROUP: CONSTRUCTION TYPE: I-2 (HOSPITAL) 1-A (UNLIMITED AREA) FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS PRIMARY STRUCTURAL FRAME - 1 HOUR NON BEARING WALL EXTERIOR - 0 HOUR NON BEARING WALL INTERIOR - 0 HOUR ROOF CONSTRUCTION AND SECONDARY MEMBERS - 1 HOUR RENOVATED AREA: 934 SQ. FT. FIRE SUPPRESSION: FULLY SUPPRESSED IN AREAS OF RENOVATION NUMBER OF STORIES: 1 VICINITY MAP: N PLUMBING MECHANICAL ELECTRICAL ABBREVIATIONS: SYMBOLS LEGEND: SET NO. SEAL
2
3 LOBBY 000 VESTIBULE 000 AREA OF WORK ROOF PLAN REFLECTED CEILING PLAN PARTIAL FLOOR PLAN ENTRANCE VESTIBULE RENOVATION WALL TYPES
4
5 MECHANICAL CURB DETAIL ELEVATION OF DECORATIVE WOOD PANEL ROOF MEMBRANE FLASHING DETAIL AREA OF WORK PLAN DETAIL AT DECORATIVE WALL PANEL DETAIL ENTRANCE VESTIBULE RENOVATION GUTTER FLASHING DETAIL RIDGE DETAIL SKYLIGHT CURB DETAIL
6
7
8
9
10
11
12
13 NOTES ENTRANCE VESTIBULE RENOVATION
14 NOTES 1 1 LINEAR DIFFUSER DUCT CONNECTION NOTES BLOWER COIL UNIT PIPING BLOWER COIL UNIT DRAIN PIPING RETURN GRILLE DUCT CONNECTION ENTRANCE VESTIBULE RENOVATION
15 MECHANICAL SPECIFICATIONS ENTRANCE VESTIBULE RENOVATION
16 1 1 1 ENTRANCE VESTIBULE RENOVATION
17 NOTES: 1. VERIFY FINISH WITH ARCHITECT/OWNER. 2. FIXTURE TO BE MOUNTED IN TRACK SYSTEM; LBL LIGHTING #RAIL-ST-CLEAR-SC-48/49. PROVIDE LOV VOLTAGE TRANSFORMER; LBL LIGHTING #TRANS-RMTE-152. PROVIDE ALL NECESSARY MOUNTING CLIPS, ADAPTERS, CONNECTORS, ETC. AS NEEDED FOR FULLY FUNCTIONAL SYSTEM. FIXTURE SYMBOL FLUOR. QUANTITY INCAN. LAMPS LED FIXTURE WATTAGE G.E. LAMP CAT. NO. FIXTURE VOLTAGE MANUFACTURER & CATALOG NO. OTHER ACCEPTABLE MANUFACTURERS DESCRIPTION WHITE NICKEL TRIM COLOR MOUNTING SIZE (IN.) S--SURFACE R--RECESSED SM-STEM MTD. WM-WALL MTD. C--CHAIN MTD. UC-UNDER CAB. CS-CEIL. SURFACE L2 11 INCLUDED 120 AMERICAN GLASS LIGHT CO. # EDGAR 232-FL-2700K APPROVED EQUAL - - S DIA L3 6 INCLUDED 120 LBL LIGHTING # HB325 - AM-SC-06-LED-MRL APPROVED EQUAL LIGHT TRACK W/ HEADS - S L4 20 INCLUDED 120 AMERICAN GLASS LIGHT CO. # LASZLO -350-S K APPROVED EQUAL WALL SCONCE - S L5 20 INCLUDED 120 PHILIPS # C4X4L10-DL-30K-CCD-W APPROVED EQUAL LED DOWNLIGHT - R CHROME BRONZE STANDARD SEE NOTE WIDTH OR DIAMETER LENGTH OR HEIGHT DEPTH SEE NOTE H1 a H1 (ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS PROJECT.) WP EM S E E/R 3 ~ B1 b B1 WEATHERPROOF EMERGENCY SURFACE MOUNTED EXISTING REMOVE AND RELOCATE ELECTRICAL EQUIPMENT AND/OR DEVICE. NOTE SYMBOL - APPLIES ONLY TO SHEET ON WHICH NOTE IS SHOWN. DETAIL B SHOWN ON SHEET E2. ELECTRICAL CONNECTION REQUIRED. EXIT LIGHTING FIXTURE. ARROWS AS INDICATED. LIGHTING FIXTURE; CAPITAL LETTER DENOTES FIXTURE TYPE. LOWER CASE LETTER DENOTES SWITCHING ARRANGEMENT. LIGHTING FIXTURE ON EMERGENCY CIRCUIT. W4 60 X1 3 INCLUDED INCLUDED 120 PEERLESS #RD4W4-W20/20-8FT-R8-120-EZB-SCT-LP835-C032 APPROVED EQUAL WALL DIRECT/INDIRECT WM DUAL-LITE #LECSRXWAW APPROVED EQUAL SINGLE-FACED EXIT LIGHT R J JUNCTION BOX. DASHED SYMBOL INDICATES THAT PARTICULAR OUTLET OR DEVICE TO BE REMOVED AND CIRCUITRY MADE CONTINUOUS WHERE REQUIRED. E EXISTING OUTLET OR DEVICE TO REMAIN, MAINTAIN EXISTING CIRCUITRY. 20A-125V HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R (18" M.H.), HUBBELL #HBL8300I 20A-125V HOSPITAL GRADE DOUBLE DUPLEX RECEPTACLE. NEMA 5-20R, (18" M.H.) TWO-GANG ASSEMBLY; HUBBELL #HBL8300I 20A-125V HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R. (46" M.H. OR AS NOTED ON ARCHITECTURAL ELEVATIONS). HUBBELL #HBL8300I 1. WORK MUST CONFORM TO THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE AND OTHER APPLICABLE LOCAL, STATE AND FEDERAL LAWS, ORDINANCES AND REGULATIONS. WHERE DRAWINGS OR SPECIFICATIONS EXCEED CODE REQUIREMENTS, THE DRAWINGS AND SPECIFICATIONS SHALL GOVERN. INSTALL NO WORK CONTRARY TO MINIMUM LEGAL STANDARDS. 2. ALL ELECTRICAL WORK SHALL BE INSPECTED AND APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 3. PROVIDE OFFSETS IN SYSTEM RUNS, ADDITIONAL FITTINGS, NECESSARY CONDUIT, PULL BOXES, CONDUCTORS, SWITCHES AND DEVICES REQUIRED TO COMPLETE THE INSTALLATION, OR FOR THE PROPER OPERATION OF THE SYSTEM. 4. AS EACH WIRING SYSTEM IS COMPLETED, IT SHALL BE TESTED FOR CONTINUITY AND FREEDOM FROM GROUNDS. 5. WORK SHALL BE SO PLANNED AND EXECUTED AS TO PROVIDE REASONABLE CONTINUOUS SERVICE OF EXISTING SYSTEMS THROUGHOUT THE CONSTRUCTION PERIOD. WHERE NECESSARY TO DISRUPT SERVICES FOR SHORT PERIODS OF TIME FOR CONNECTION, ALTERATION OR SWITCH OVER, THE OWNER SHALL BE NOTIFIED IN ADVANCE AND OUTAGES SCHEDULED AT THE OWNER'S REASONABLE CONVENIENCE. 6. ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH REQUIREMENTS OF THE JURISDICTION. 7. WHERE CONDUITS ARE TO PASS THRU, ABOVE OR BEHIND EXISTING WALLS, PARTITIONS, FLOORS, ROOF OR CEILING, CUTTING, PATCHING, REFINISHING AND PAINTING OF SAME SHALL BE INCLUDED. CORE DRILLING AND SAW CUTTING SHALL BE UTILIZED WHERE PRACTICAL. CONTRACTOR TO EXAMINE WHERE FLOORS AND WALLS ETC. ARE TO BE CUT FOR PRESENCE OF EXISTING UTILITIES UTILIZING X-RAY TECHNOLOGY IF NECESSARY. 15. CONDUIT SHALL BE 3/4" DIAMETER OR LARGER EXCEPT 1/2" SIZE MAY BE USED FOR THE FOLLOWING CASES: FLEXIBLE CONDUIT, SWITCH LEGS OR CONDUIT CARRYING CONTROL WIRING ONLY. TERMINATIONS OF ALL CONDUITS SHALL BE SECURED BY LOCK- NUTS AND APPROVED BUSHINGS TIGHTENED UP TO SECURE ELECTRICAL AS WELL AS MECHANICAL INTEGRITY OF THE CONDUIT NETWORK. 16. METALLIC CONDUIT, SUPPORTS AND EQUIPMENT SHALL BE GROUNDED IN STRICT ACCORDANCE WITH THE LATEST ISSUE OF THE NEC. THE ENTIRE CONDUIT SYSTEM SHALL BE SECURED BY APPROVED CONNECTORS AND TIGHTENED TO ASSURE ELECTRICAL AS WELL AS MECHANICAL INTEGRITY SO TO PROVIDE AN UNBROKEN GROUNDING PATH. A SEPARATE COPPER GROUNDING CONDUCTOR SHALL BE PULLED WITH ALL BRANCH CIRCUITS. 17. DEVICE AND JUNCTION BOXES GALVANIZED STEEL, CODE GAUGE AND SIZE BY STEEL CITY, RACO, APPLETON OR R&S. BOXES CONNECTING MORE THAN ONE PAIR OF CONDUCTORS TO BE MINIMUM 4" X 4", OR 4" OCTAGONAL SIZE. USE ADAPTER PLATES FOR DEVICES WHERE NUMBER OF CONNECTIONS OR OTHER CONDITIONS DICTATE. WRITE PANEL AND CIRCUIT NUMBER ON JUNCTION BOX WITH PERMANENT MARKER. 18. FIRE ALARM WORK SHALL BE AN EXPANSION/MODIFICATION OF THE EXISTING PYROTRONICS FIRE ALARM SYSTEM. WIRING SHALL BE IN CONDUIT INSTALLED PER DIRECTION OF THE MANUFACTURER. TEST AND DEMONSTRATE SYSTEM. INSTALLER SHALL MEET STATE OF OHIO REQUIREMENTS FOR CERTIFICATION. THE CONTRACTOR OR HIS FIRE ALARM SUPPLIER/INSTALLER SHALL SUBMIT SHOP DRAWINGS TO THE LOCAL FIRE OFFICIAL FOR PERMIT, REVIEW AND APPROVAL 19. GF L F 15 L 15 S S K 20A-125V HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R, WITH GROUND FAULT CIRCUIT INTERRUPTER (18" M.H.). HUBBELL #GFDR8300HILA SPECIAL PURPOSE SIMPLEX RECEPTACLE. REFER TO PLANS FOR ADDITIONAL INFORMATION. HEAVY DUTY SPECIFICATION GRADE SINGLE POLE WALL SWITCH (46" M.H.). LOW VOLTAGE "CENTER OFF MOMENTARY TOGGLE WALL SWITCH" (46" M.H.). KEYED SWITCH (46" M.H.). DUAL TECHNOLOGY CEILING MOUNTED VACANCY SENSOR RATED FOR 1000 SQ. FT. DATA OUTLET (18"M.H. OR AS NOTED ON ARCHITECTURAL ELEVATIONS). 4" SQUARE OUTLET BOX WITH SINGLE GANG RING AND BLANK COVERPLATE. STUB AN EMPTY 1" BUSHED CONDUIT ABOVE ACCESSIBLE CEILING. TECHNOLOGY CABLING SHALL BE PROVIDED BY OWNER'S VENDOR. FIRE ALARM CHIME & SIGNAL LIGHT (80" A.F.F.), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. FIRE ALARM SIGNALING LIGHT (80" A.F.F.), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. CEILING MOUNTED SMOKE DETECTOR. DUCT MOUNTED SMOKE DETECTOR. 8. THE ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING WORK WHICH IS ASSOCIATED WITH HIS TRADE, AND WHICH WILL BE SUPERFLUOUS WHEN THE NEW SYSTEM IS INSTALLED AND MADE OPERATIONAL. REMOVE INACTIVE WIRING BACK TO THE LAST ACTIVE JUNCTION BOX, PANELBOARD OR PIECE OF EQUIPMENT. 9. FIRESTOPPING ASSEMBLIES SHALL BE TESTED AND RATED IN ACCORDANCE WITH ASTM E814 AND E119 AND LISTED IN ACCORDANCE WITH UL 1479, AS PUBLISHED IN THE UL FIRE RESISTANCE DIRECTORY. FIRESTOPPING SHALL PROVIDE A FIRE RATING EQUAL TO THAT OF THE CONSTRUCTION BEING PENETRATED AND MANUFACTURED BY SPECIFIED TECHNOLOGIES. 10. A COMPLETE ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN. WORK INCLUDES, BUT IS NOT NECESSARILY LIMITED TO THE FOLLOWING PRINCIPAL CATEGORIES: A B C D E F WIRING DEVICES. POWER WIRING. MISCELLANEOUS WIRING AND INTERLOCKS. EQUIPMENT CONNECTIONS. LIGHTING FIXTURES. FIRE ALARM. A. REWORK OF TECHNOLOGY CABLING BY OWNER'S VENDOR. T ELCU PUBLIC ADDRESS CEILING SPEAKER. UTILIZE/EXTEND LOCAL CIRCUIT. MUSIC SPEAKER. CATV OUTLET (90" M.H.) PROVIDE 4" SQ. BOX WITH SINGLE GANG RING AND.75" BUSHED CONDUIT STUBBED ABOVE ACCESSIBLE CEILING. CLOSED CIRCUIT TELEVISION CAMERA (CCTV). NURSE CALL STAFF EMERGENCY STATION. PROVIDE ROUGH-IN PER OWNER'S VENDOR REQUIREMENTS. NURSE CALL CODE BLUE STATION. PROVIDE ROUGH-IN PER OWNER'S VENDOR REQUIREMENTS. PATIENT TOILET STATION WITH EMERGENCY PULL CORD. PROVIDE ROUGH-IN PER OWNER'S VENDOR REQUIREMENTS. UL924 EMERGENCY LIGHTING CONTROL UNIT EQUAL TO WATT STOPPER #ELCU-200. DISCONNECT SWITCH. 11. PROVIDE FLUSH WALL MOUNTED HOSPITAL GRADE WIRING DEVICES AS SHOWN. DEVICES SHALL BE IVORY FOR NORMAL POWER AND RED FOR EMERGENCY POWER. 12. PROVIDE A DEVICE PLATE TO SUIT EACH PARTICULAR APPLICATION. WALL PLATES SHALL BE.032" THICK STAINLESS STEEL. WALL PLATES SHALL BE IDENTIFIED WITH ADHESIVE LABELS TO INDICATE PANEL AND CIRCUIT NUMBER. MOTOR STARTER. COMBINATION MOTOR STARTER AND DISCONNECT SWITCH. ELECTRIC MOTOR. EPO SWITCH (46" M.H.). 13. NONMETALLIC SPRING TYPE INSULATED PRESSURE CONNECTORS AS MADE BY "SCOTCHLOK" OR EQUAL SHALL BE USED FOR SPLICING CONDUCTORS. CONNECTIONS IN NO. 8 AND LARGER SHALL BE SPLICED BY APPROVED PRESSURE TYPE MECHANICAL CONNECTORS AND INSULATED WITH RUBBER OR VINYL TAPE TO ACHIEVE A RESISTANCE EXCEEDING 150% OF THE CONDUCTOR INSULATION. WIRE SHALL BE PULLED ONLY AFTER THAT SECTION OF THE CONDUIT RUN IS PROVEN TO BE CLEAR OF OBSTRUCTIONS, DIRT, MOISTURE AND GREASE. BRANCH CIRCUIT WIRING SHALL BE PULLED WITHOUT THE USE OF LEVERS OR HEAVY PULLING DEVICES. Z CEILING MOUNTED NURSE CALL DOME LIGHT BY OWNER'S VENDOR. NURSE CALL ZONE DOME LIGHT WITH AUDIBLE TONE BY OWNER'S VENDOR. CCTV MONITOR MATRIX SYSTEM CARD READER (46" M.H.); CAT # C 14. CONDUIT SHALL BE USED FOR ALL WIRING. CONDUIT SYSTEMS MAY BE ANY ONE OR COMBINATION OF THE FOLLOWING, WITHIN RESTRICTING LIMITS INDICATED. CONDUIT TYPES NOT LISTED SHALL NOT BE USED. MATRIX SYSTEM EGRESS/MOTION SENSOR; CAT #DS150 MATRIX SYSTEM DOOR STATUS CONTACT; CAT #1078CW A B C D E RIGID GALVANIZED CONDUIT - NO RESTRICTIONS. INTERMEDIATE GRADE GALVANIZED THREADED CONDUIT - NO RESTRICTIONS. THINWALL CONDUIT WITH APPROVED CONNECTOR FITTINGS TO ASSURE GROUNDING CONTINUITY, SUBJECT TO THE FOLLOWING RESTRICTIONS: 1 NOT IN POURED CONCRETE, OUTDOORS, OR UNDERGROUND. FLEXIBLE METAL CONDUIT (GREENFIELD TYPE) GALVANIZED. USE RESTRICTED TO THE FOLLOWING APPLICATIONS: 1 CONNECTIONS TO LIGHTING FIXTURES, MAXIMUM LENGTH 6 FT. LIQUID TIGHT FLEXIBLE METAL CONDUIT WITH WATER TIGHT OIL RESISTANT OUTER PVC COVERING. USE REQUIRED: 1 CONNECTIONS TO MOTORS OR CONTROLS ON DYNAMIC EQUIPMENT. 2 CONNECTIONS TO TRANSFORMERS. ELECTRONIC DOOR LOCK BY G.C. PROVIDE CONNECTION AND INTERFACE WITH MATIX SYSTEM. PHOTOCELL; TORK #2107 ENTRANCE VESTIBULE RENOVATION
18 ENTRANCE VESTIBULE RENOVATION
M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings
1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL
More informationFIRE ALARM: BY OTHERS, IF REQUIRED.
x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,
More informationFIRE ALARM: BY OTHERS, IF REQUIRED.
x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT
More informationA. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.
DIVISION 26 ELECTRICAL SECTION 26 27 26 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. B. Specialty switches and outlets
More informationSECTION (16140) - WIRING DEVICES
SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -
More informationDONALD H. BERG, ARCHITECT
DONALD H. BERG, ARCHITECT DVA PROJECT 632-CSI-402 PET/CT ROOM #A0-10 RENOVATION BASEMENT LEVEL, BUILDING 200 ARCHITECT S PROJECT No. 0917-02 ADDENDUM NO. 1 JUNE 25, 2018 Page 1 of 1 ARCHITECTURAL 1. Specifications:
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as
More informationMounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate
Mounting Plate 147-10 > Momentary switch push button > Stainless steel faceplate The Edwards Cat. No. 147-10 Mounting Plate when used with the catalog series 620 Push Buttons (page 10-9) forms a convenient
More informationSECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM
SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationSECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.
SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance
More information.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.
Fitness Facility Addition Page 1 1.1 CODES AND STANDARDS.1 Do complete installation in accordance with the latest edition of the CSA C22.1 as amended by the latest editions of the National Building Code
More information1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.
PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 REFERENCES... 2 1.4 DEFINITIONS... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 3 1.7 COORDINATION... 3 1.8 DELIVERY, STORAGE, AND
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationA. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.
DIVISION 26 ELECTRICAL SECTION 26 51 13 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings. B. Luminaire
More informationTABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5
DOC Cremer Heating and Hot Water Plant Project Number: M 1411-04 TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION 21 30 00- WATER BASED FIRE PROTECTION SYSTEMS... 5 SECTION 22 40 00 -PLUMBING
More informationSECTION ELECTRICAL IDENTIFICATION
SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSECTION INTRUSION DETECTION SYSTEM
SECTION 13845 INTRUSION DETECTION SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested intrusion detection system, bearing Underwriters Laboratories (UL) mercantile listing
More informationSECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary
More informationSANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)
FIRE DEPARTMENT SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA. 95032-1818 (408) 378-4010 (408) 378-9342 (fax) www.sccfd.org STANDARD DETAILS & SPECIFICATIONS Spec No C-4 Rev. Date 03/10/10 SUBJECT:
More informationBuilding Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS
BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used
More informationA. This Section includes the following lighting control devices:
Attachment G LIGHTING CONTROL SPECIFICATIONS (Download Document separately) LIGHTING CONTROL SPECIFICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including
More informationSECTION EXTERIOR LIGHTING
SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26
More informationSECTION : FIRE ALARM & DETECTION SYSTEMS
SECTION 28 31 10: FIRE ALARM & DETECTION SYSTEMS 1. GENERAL A. This section applies to fire detection/alarm system and carbon monoxide system components and equipment installed during new construction
More informationPort of Portland Conveying Equipment Guidelines
Role: Consultant for the Port Design Guidelines Port of Portland Conveying Equipment Guidelines ELEVATOR, ESCALATOR, AND MOVING WALK DESIGN OVERVIEW The Division 14 specification sections include appropriate
More informationSECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL
SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply
More informationSECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.
SECTION 26 0553 PART 1 GENERAL 1.1 SECTION INCLUDES A. Electrical identification requirements. B. Identification nameplates and labels. C. Wire and cable markers. D. Voltage markers. E. Underground warning
More informationCT CABINET AND UTILITY METERING WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY 200A MCB 200A, 120/208V, 3Ø, 4W BOARD TVSS CIA ALARM 400A, DOUBLE-THROW SWITCH PORTABLE GENERATOR CONNECTION ENCLOSURE EXISTING
More informationHMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3
HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California 95833 September 15, 2016 Woodland Joint Unified School District Spring Lake Area Elementary School HMC No. 3535003.000 DSA Appl.
More informationA. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR
September 2012, rev. 00 26 0553 Identification for Electrical Systems PART 1. GENERAL 1.01 Summary A. Section Includes: 1.02 Submittals 1. Identification for raceways. 2. Identification of power and control
More informationSECTION LIGHTING CONTROL DEVICES
SECTION 16145 LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationKITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete automatic fire suppression system for the exhaust hood, including necessary accessories.
More informationCOMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods
1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,
More informationB. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION ISOLATED POWER SYSTEMS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationFIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.
15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.
More informationNORTH BAY PARRY SOUND HEALTH
NORTH BAY PARRY SOUND HEALTH LEGEND: (ARCHITECTURAL) DA-01 X-RAY APPROVAL PLAN DA-02 DETAILS DA-03 AIR TECHNIQUES AS30 AIR COMPRESSOR D AIR TECHNIQUES VS50H VACUUM UNIT 11'-3" [3.43] EXAM.1 EXAM.2 9'-7"
More informationI.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape
More information1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.
September 2012, rev. 00 26 2416 Panelboards PART 1. GENERAL 1.01 Summary A. Section includes: 1.02 Definitions 1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load
More informationA. This Section includes the following lighting control devices:
SECTION 26 09 23 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationElement D Services Electrical
PART 1 - GENERAL 1.01 OVERVIEW A. This Section includes design standards and requirements for electrical service and distribution. This is a design standard and is not intended to be used as a Specification.
More informationThe following information shall become and form part of the contract documents.
October 4, 206 To: Attention: Re: All Bidders All Bidders JCBE Gymnasium HVAC Upgrades BC#: 206433 Edmonds Project No.: BHM6090 All bidders, The following information shall become and form part of the
More informationB. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).
SECTION 28 13 00 - ACCESS CONTROL PART I - GENERAL 1.1 SUMMARY A. This specification section describes the furnishing, installation, commissioning, and programming of a complete, turnkey, hardwired Andover
More informationElements Headwall System (P2008A)
Figure 1. Elements Headwall System American Society of Mechanical Engineers 3 (ASME ) ASME B16.22: Wrought Copper and Copper Alloy Solder Joint Pressure Fittings American Standard Test Method 4 International
More information1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.
FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment
More informationLIGHTING CONTROL DEVICES
SECTION - PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationSECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM
SECTION 213100 WET PIPE FIRE PROTECTION SPRINKLER SYSTEM PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. The requirements of the General Conditions and Supplementary Conditions apply to all work herein.
More informationB. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.
(816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the
More informationC. Pigtail: Short lead used to connect a device to a branch-circuit conductor.
SECTION 26 27 26 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationB. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.
DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS
More informationSECTION (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS
SECTION 26 05 53 (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Electrical identification materials and devices required to comply with ANSI C2, NFPA
More information9 E. Scarborough Park Concession Stand and Restroom And / Or Lake Kirby Park Softball Fields Restroom Addition
Addendum NO. 1 Issue Date: October 20, 2016 Project: City of Abilene 10 20 2016 Scarborough Park Concession Stand and Restroom And / Or Lake Kirby Park Softball Fields Restroom Addition I WILL STAT AMR.DUNCA
More informationSCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL
SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm
More informationDIVISION 16 ELECTRICAL
DIVISION 16 ELECTRICAL Saratoga Springs / standards / 02-2004 Page - 0 ELECTRICAL SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.01 SECTION INCLUDES A. Grounding electrodes and conductors, equipment
More informationEmery County Senior Center Green River 06/07
SECTION 260923 - LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationRESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS
RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS Key Questions for Residential Inspections 1. What wiring methods will be used, and are the wiring methods suitable for the conditions? 2. Will multiwire branch
More informationValuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:
PERMIT FEE: $ 907 Billy Mitchell Blvd. P: (210) 228-1022 Fire Alarm Permit Application PAYMENT TYPE: Check Credit Card Charge to Job #: (Please complete all of the following information. Please PRINT).
More informationUniversity Design Standard Fire Alarm Systems
1.0 Overview University Design Standard Fire Alarm Systems This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit
More informationDear Concessionaire,
Dear Concessionaire, In order to provide a comprehensive review & inspection of the Vendor application please review the following as guidance to a complete application and preparedness for inspection.
More informationINSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: Mech Code 601 Effective: 2-07-79 DOCUMENT NO. P/BC 2002-018 Revised: 9-25-03 Previously Issued As: RGA 2-79, MGD101 INSTALLATION OF ACCESS FLOOR
More informationTown of Cicero Local Code Amendments
Town of Cicero Local Code Amendments 2009 International Residential Code Local Amendments: DELETE Table R302.1 (Exterior Walls), see Attachment A. DELETE Exception for Subsection R313.2 (One and Two-Family
More informationSECTION NURSE CALL SYSTEM
NURSE CALL SMARTCARE NURSE CALL SOLUTION Architectural Specifications Part 1 General SECTION 275223 - NURSE CALL SYSTEM 1.0 Summary 1.1 This section includes nurse call system and requirements for system
More informationC. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.
SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this
More informationSECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS
SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Nameplates and labels B. Wire and cable markers C. Conduit markers 1.2 REFERENCES A. NFPA 70 - National Electrical
More informationMoreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline
Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to
More informationCHAPTER 8 ELECTRICAL
CHAPTER 8 0 8.1 GENERAL... 3 8.2 REQUEST FOR PROPOSAL DEVELOPMENT... 3 8.3 DESIGN DEVELOPMENT... 3 8.3.1 CONCEPT (30%) DESIGN SUBMITTAL REQUIREMENTS... 3 8.3.1.1 Concept Design Analysis... 3 8.3.1.1.1
More informationSECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM
PART 1 - GENERAL 1.01 SUMMARY SECTION 08 34 84 ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM A. Section Includes: Fire protective elevator smoke containment curtain system designed to provide a tight-fitting,
More informationUBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 27 05 05 Communication Rooms Design Guidelines 2.13 1.2 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations Electrical
More informationBuilding Self-Inspection Program
Building Self-Inspection Program www.tridentinsurance.net Lines of Business: Property, General Liability, Worker s Compensation, Public Official Liability Risk Control Strategy/Key Issues: Reduce physical
More informationSECTION LIGHTING CONTROLS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationSECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)
SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill
More informationHIGH-RISE RETROFIT ORDINANCES - NO and NO
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.8604 Effective: 9-06-90 DOCUMENT NO. P/BC 2002-054 Revised: 4-15-03 Previously Issued As: MGD 88 HIGH-RISE RETROFIT ORDINANCES - NO.
More informationDivision 26 ELECTRICAL TABLE OF CONTENTS
Division 26 ELECTRICAL TABLE OF CONTENTS 26 1000 GENERAL... 33 A. CODE... 3 B. RELATED SECTIONS... 3 C. ABBREVIATIONS... 3 D. DEFINITIONS... 3 E. DRAWING REQUIREMENTS... 3 F. EQUIPMENT SERVICE ACCESS AND
More informationDivision 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21
Division 21: FIRE SUPRESSION 21 1313 WET-PIPE SPRINKLER PROTECTION SYSTEM Table of Contents 1 Division 21 SECTION 21 1313 WET-PIPE SPRINKLER PROTECTION SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A.
More informationSECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE
SECTION 21 1313 WET-PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Wet-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.02 RELATED
More informationDESIGN & CONSTRUCTION GUIDELINES
ADMINISTRATIVE SERVICES 4202 E. FOWLER AVENUE, FPC110 PHONE: (813) 974-2625 FACILITIES PLANNING & CONSTRUCTION TAMPA, FLORIDA 33620-7550 WEBSITE: USF.EDU/FPC DESIGN & CONSTRUCTION GUIDELINES DIVISION 21
More informationBUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS
BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by
More informationTaming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.
Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes Comparing the Codes: NFPA 101 Life Safety Code (2000) (NFPA) International Building Code (2012) (IBC) Chicago
More informationREFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS
*s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT
More informationELECTRICAL SUPPLIES NATIONAL REFRIGERATION PRODUCTS WIRE NUTS HEAT SHRINK TUBING CABLE STAPLES CABLE MARKERS
WIRE NUTS HEAT SHRINK TUBING Color-coded connector shells are made from high dielectric, smooth polypropylene plastic to eliminate porosity and surface cracking. Resists practically all chemical action
More informationDESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES
2.07 ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.07 It is expected that the electrical design professional will conform to accepted good engineering design practices.
More informationSECTION SPRINKLER SYSTEMS
SECTION 15325 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Wet-pipe sprinkler systems. B. Preaction sprinkler systems. C. System design, installation, and certification. D. Fire department
More informationSECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35
SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1 Overview of Low-Voltage and Power-Limited Systems...3 Chapter 4 Equipment for General Use...3 Chapter 5 Special Occupancies...3 Chapter 6 Special Equipment...4
More informationB. Section Identification for Fire Suppression Piping and Equipment.
SECTION 211300 - FIRE SUPPRESSION SPRINKLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.2 RELATED
More informationSECTION COMMERCIAL-KITCHEN HOODS
SECTION 23 38 13 COMMERCIAL-KITCHEN HOODS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section that are not applicable and renumber
More informationELECTRICAL SYSTEMS ASSESSMENT Hanover High School
ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL DISTRIBUTION SYSTEM:?? The existing electrical service consists of an underground primary service originating at a utility pole on Cedar Street,
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-23 83 00.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-15768N (September 1999) UNIFIED FACILITIES GUIDE
More informationELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR
More informationSpring Test 6 due 04/26/2013
Spring Test 6 due 04/26/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. The article that covers TV wiring installations in residences
More informationSECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR
SECTION 08734 COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead
More informationA. Shop Drawing submittals shall include, but not be limited to, the following:
SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical
More informationTABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51
TABLE OF CONTENTS About This Textbook...xi How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...
More informationBuilding and Grounds Self-Inspection Program
www.alterisus.com Building and Grounds Self-Inspection Program Each building and its accompanying grounds should be inspected at regular intervals, ideally on a monthly or quarterly basis. In this way,
More informationPANELBOARDS & BUILDING DISTRIBUTION
262416 PANELBOARDS & BUILDING DISTRIBUTION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Distribution panelboards 2. Power panelboards B. Related Sections: 1.02 POLICY 1. CU Standard 260500, Basic
More informationPLATTEVILLE MIDDLE SCHOOL
Architectural The building has aluminum clad wood awning windows in combination with aluminum fixed glass units. They appear to be exterior glazed with insulated glazing. See photo 2. Platteville Middle
More informationIntroduction Limited-Use / Limited-Application
NBL DEC 2015 V1 Introduction Niagara Belco Ltd has been in the elevating industry for 30 years, we take pride in our work and aim to please all of our customers. We appreciate your business and always
More informationSCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003
SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003 No. Discipline Sent to Name Item Date Noted Date Resolved How item was resolved SCO # 1Punch listed items were noted below on
More informationRelated Sections: TBD. Effective Date: January 1, 2016
Description: The purpose of the section is to highlight the current applicable UMCP Design Standards for the design, selection and, installation of lighting fixtures within buildings. Related Sections:
More informationDEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and
DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and equipment), and discussions with maintenance personnel
More information