Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.
|
|
- Arron Tate
- 5 years ago
- Views:
Transcription
1 Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 CondI Inductive Conductivity Measurement Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol. Icons supply operating messages and signal unusual operating states. Mode indicators show the current operating mode. Suitable sensors a wide variety of commercial European or US electrodeless sensors temperature sensors Pt 100, Pt 1000, NTC 100 kohms Recommended Installation Sets Flow Immersion SE 660 ARF 215 SE 660 ARD
2 For up-to-date information, please visit Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Product Line Order No. Stratos Eco 2405 CondI process analyzer for measuring conductivity using electrodeless sensors 2405 CondI Mounting Accessories (see page 566) Order No. Pipe-mount kit ZU 0274 Panel-mount kit ZU 0275 Protective hood ZU 0276 Connection Cond measurement Power supply Control room/ station ms, %, SAL, Sensocheck V AC/DC ma 0(4) 20 ma ms/cm Stratos Eco 2405 CondI ma 0(4) 20 ma Temp. Pt 100 / Pt 1000 NTC 100 kohms Water Temperature Contacts Wash Alarm Limit value Sensor cleaning Alarm Power supply Limit value Terminal Assignments 555
3 Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 CondI Specifications Cond input input for electrodeless conductivity sensors: SE 655, SE 656, SE 660 and others Display ranges conductivity ms/cm concentration % by wt salinity (0 35 C) Ranges conductivity ms/cm ms/cm ms/cm ms/cm S/m S/m concentration % % salinity (0 35 C) Response time (T90) Measurement error 1, 2, 3 } approx. 2 s 1% meas. val ms Temperature compensation*} (reference temp 25 C) (OFF) (LIN) (NLF) without linear characteristic %/K natural waters to EN (0 35 C) Concentration determination Sensor standardization 1 NaCl % by wt (0 100 C) 2 HCl % by wt ( C) 3 NaOH % by wt (0 100 C) 4 H2SO % by wt ( C) 5 HNO % by wt ( C) entry of cell factor with simultaneous display of conductivity and temperature entry of conductivity of calibration solution with simultaneous display of cell factor and temperature product calibration zero adjustment temperature probe adjustment Permissible cell factor Permissible transfer ratio Permissible zero offset Sensocheck Sensoface Sensor monitor Temperature input*} ±0.5 ms/cm primary coil and lines monitored for short circuit secondary coil and lines monitored for open circuit provides information on the sensor condition (evaluation of zero point, Sensocheck ) sensor monitor for validation of sensor and complete measured-value processing (display: resistance/temperature) Pt 100 / Pt 1000 / NTC 100 kohms, 2-wire connection, adjustable Measuring range Pt 100 / Pt C ( F) NTC 100 kohms C ( F) Resolution 0.1 C/1 F Measurement error 1, 2, 3 } < 0.5 K (< 1 K for Pt 100; < 1 K for NTC > 100 C) 556
4 For up-to-date information, please visit Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Specifications continued Output 1 0/4 20 ma, max. 10 V, floating (galvanically connected to output 2) Process variable*} Overrange*} Output filter*} (attenuation) Measurement error!} Start/end of scale Minimum span conductivity, concentration, or salinity 22 ma in the case of error messages low-pass, filter time constant s < 0.3 % current value ma as desired within range 5 % of selected range Output 2 0/4 20 ma, max. 10 V, floating (galvanically connected to output 1) Measured variable Overrange*} Output filter*} (attenuation) Measurement error!} temperature 22 ma in the case of error messages low-pass, filter time constant s < 0.3 % current value ma Start/end of scale*} C/ F Span allowed K/ F Alarm contact Contact response Alarm delay Limit contact Contact response*} Delay*} Setpoints*} Hysteresis*} Cleaning contact Contact response*} relay contact, floating AC < 250 V / < 3 A / < 750 VA N/C (fail-safe type) 10 s relay contact, floating AC < 250 V / < 3 A / < 750 VA N/C or N/O s as desired within range 0 50 % full scale clean relay contact AC < 250 V / < 3 A / < 750 VA N/C or N/O DC < 30 V / < 3 A / < 90 W DC < 30 V / < 3 A / < 90 W DC < 30 V / < 3 A / < 90 W Rinsing interval*} Rinse duration*} h (000.0 h = cleaning function switched off) s 557
5 Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 CondI Specifications continued Display Main display Secondary display Sensoface Mode indication Alarm indication Keypad Service functions Current source Device self-test Display test Last error Sensor monitor Data retention Protection against electric shock Power supply LC display, 7-segment with icons character height 17 mm, unit symbols 10 mm character height 10 mm, unit symbols 7 mm 3 status indicators (friendly, neutral, sad face) 4 mode indicators meas, cal, alarm, config further icons for configuration and messages red LED in case of alarm 5 keys: [cal] [conf] [?] [±] [enter] current specifiable for output 1 and 2 ( ma) automatic memory test (RAM, FLASH, EEPROM) display of all segments display of last error occurred display of direct, uncorrected sensor signal (electrode) parameters and calibration data > 10 years (EEPROM) protective separation of all low-voltage circuits against mains by double insulation to EN ( 15 %) 230 (+10 %) V AC/DC approx. 5 VA/2.5 W AC: Hz overvoltage category II, Class II Nominal operating conditions Ambient temperature C Transport/Storage temp C Relative humidity %, not condensing EMC EN , EN emitted interference: Class B (residential area) immunity to interference: Industry Class A: for mains > 60 V DC Explosion protection FM NI, Class I Div 2, Groups A, B, C & D T4, Ta = 55 C; Type 2 NI, Class I Zone 2, Group IIC T4, Ta = 55 C; Type 2 CSA Class I Div 2, Groups A, B, C and D, T4 Ex na IIC T4 558
6 For up-to-date information, please visit Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Specifications continued Enclosure molded enclosure made from PBT (polybutylene terephtalate) Color bluish gray, RAL 7031 Assembly wall mounting pipe mounting ZU 0274, Ø mm, _ mm panel mounting ZU 0275 cutout to DIN , sealed against panel Dimensions (mm) H x W x D 144 x 144 x 105 Ingress protection IP 65/NEMA 4X Cable glands 3 knockouts for cable glands M20 x knockouts for 1/2; NPT or rigid metallic conduit Weight approx. 1 kg * ) user-defined 1) to IEC 746 Part 1, at nominal operating conditions 2) ±1 count 3) plus sensor error 559
7 Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 Mounting Examples ZU 0274 pipe-mount kit For mounting on vertical or horizontal posts or pipes. ZU 0276 protective hood Additional protection from direct weather exposure and mechanical damage. ZU 0275 panel mounting kit For mounting in standardized panel cutout 138 x 138 mm (DIN 43700), sealed against panel. 566
8 For up-to-date information, please visit Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Dimension Drawings approx M20 x 1.5 (3 x) knockouts Ø 21.5 mm for M20 x 1.5 cable glands or conduit 1/2; (not included). ZU 0274 pipe-mount kit consisting of: 1 Self-tapping screw (4 x) 2 Pipe-mount plate (1 x) 3 Hose clamps with worm gear drive DIN 3017 (2 x) Ø ZU 0276 protective hood 132 ZU 0275 panel mounting kit max Optional for vertical or horizontal posts or pipes mm Cutout 138 x 138 mm (DIN 43700) 567
Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states.
MS Stratos MS Digital Memosens Transmitter Multi-Parameter Memosens Transmitter The digital platform. Multi-parameter transmitter With the Stratos MS, Knick is now offering a low-cost, purely digital version
More informationMEAS CAL ALARM WASH CONF APT4000 TC
APT4000 Series Toroidal Conductivity Transmitters Overview 70-82-03-42 3/01 Page 1 of 8 Specification The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,
More informationToroidal Conductivity Transmitters Series APT4000 Specifications
Toroidal Conductivity Transmitters Series APT4000 Specifications 70-82-03-42 March 2001 Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,
More informationMEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2
APT4000 Series 4-Wire Contacting Conductivity Analyzers Overview 70-82-03-45 10/03 Page 1 of 8 Specification The Honeywell Analytical Process Analyzer (APT) 4000 Series2 continuously measures conductivity,
More informationInductive Conductivity
Inductive Conductivity THORNTON Leading Pure Water Analytics 7100E Non-Fouling Sensors PEEK or PFA Wetted Parts Excellent Chemical Resistance 0/4 to 20mA Outputs for Conductivity & Tempreature 4 Relays
More informationMEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description
APT4000 Series 4-Wire ph Transmitters 3/01 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures ph or ORP in industrial processes
More informationMEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description
APT4000 Series 4-Wire ph Analyzers 70-82-03-44 10/03 Page 1 of 8 Specification Overview The Honeywell Analytical Process Analyzer (APT) 4000 Series 2 continuously measures ph or ORP in industrial processes
More informationMEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2
APT2000 Series 2-Wire Contacting Conductivity Transmitters Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously measures conductivity,
More informationAPT2000 Series 2-Wire Contacting Conductivity Transmitters User Manual MU1I-6246 Revision 1 01/00
21^11 APT2000 Series 2-Wire Contacting Conductivity Transmitters User Manual 70-82-25-95 MU1I-6246 Revision 1 01/00 Copyright, Notices, and Trademarks Copyright 1999 by Honeywell Inc. Revision 1 01/00
More informationSlope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2
APT 2000 Series 2-Wire ph Transmitters 70-82-03-32 2/00 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously
More informationDissolved Oxygen Measurement liquisys M COM 223 / 253
Technical Information TI 199C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 / 253 Oxygen Controller Benefits at a glance Liquisys M COM 223 Liquisys M COM 253 Due to the modularity of its design,
More informationDL423 DirectLine Sensor Module for Conductivity Measurement Specifications
DL423 DirectLine Sensor Module for Conductivity Measurement Specifications 70-82-03-47 January 2003 Overview DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as
More informationGas cylinder scale Model GCS-1
Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in
More informationDissolved Oxygen Measurement liquisys S COM 223 / 253
Technical Information TI 199C/07/en No. 51500281 Dissolved Oxygen Measurement liquisys S COM 223 / 253 Oxygen Transmitter Benefits at a glance Measuring transmitter in field or panel-mounted housing Universal
More informationFigure 1 DirectLine DL423 Sensor. Description, continued
DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 1/03 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell
More informationAnalyze IT Zirconia Oxygen Analyzer for Small Boiler Applications
Data Sheet Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Ideal for small gas/oil fired boilers Cost effective solution for OEM outlets with a quick return on end-user investment Continuous
More information873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity
Product Specifications PSS 6-1C1 F 873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity METAL ENCLOSURE VERSION MOUNTING HARDWARE NOT SHOWN EASY-TO-USE
More informationSoftware Version 2.01 LEVEL MONITOR MODEL 220
Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationLow Temperature Zirconia Oxygen Analyzer
Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive
More informationFigure 1 DirectLine DL423 Sensor. Description, continued
DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 4/02 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell
More informationCorporate Profile. needs and product demands. CON 08X /03 Rev 0
Corporate Profile A leader in the field of electrochemical instrumentation, Eutech Instruments is a dynamic company rapidly positioning itself globally as a leading manufacturer of electrochemical instrumentation
More informationTemperature Measurement Transmitters for field mounting
Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted
More informationTurbimax CUE21 / CUE22
Technical Information Turbimax CUE21 / CUE22 Turbidimeter for on-line measurement Application On-line continuous monitoring of clean water: Drinking water Treated process water Your benefits Versions with
More informationZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement
Data sheet High Temperature Zirconia Oxygen Analyzer Superior technology and quality from the world leader in oxygen measurement User-friendly language options selectable system analysis comprehensive
More informationModels 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers
Data sheet USP Conductivity Analyzers A conductivity system designed to meet USP for the Pharmaceutical Industry incorporating automatic Stage 1 test Meets USP requirements ensures compliance
More informationfor relative humidity and temperature
1 861 1861P01 Duct sensor for relative humidity and temperature QFM65 Operating voltage AC 24 V Signal output DC 0...10 V for relative humidity and temperature Measurement accuracy ±3 % r. h. within the
More informationProcess Alarm Module RTA 421
Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders
More informationUniversal controller for panel mounting Models CS6S, CS6H, CS6L
Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing
More informationQAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products
1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationGMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions
Worldwide upplier of Gas Detection olutions GfG Instrumentation 1194 Oak Valley Drive, uite 20 Ann Arbor, MI 48108 800-959-0329 tel 734-769-1888 fax email: info@gfg-inc.com GMA4100-DP Control Panel Operation
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit
ABB MEASUREMENT & ANALYTICS DATA SHEET C50 1/16 DIN controller / alarm unit 2 C50 1/16 DI N CON TROLL ER / AL ARM U NIT DS/C 50-E N RE V. M Measurement made easy C50 the 1/16 DIN controller to suit your
More informationImprove Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...
Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable
More informationSTT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009
STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full
More informationDL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications
DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications 70-82-03-48 January 2003 Overview The DirectLine DL424/425 Sensor Modules are part of a family of products developed
More informationLINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage
LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420
More informationRTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals
Technical Information RTA421 Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Application Plant and machine construction Panel builders Process monitoring Process
More informationQAF64.2-J QAF64.6-J. Frost detector. for use on the air side
s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage
More informationLINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems
LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationMultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price
MultiMeter 44 Transmitter-regulator with 1, 2 or 3 channels MultiMeter 44 is a modular meter that can be configured with one, two or three channels. It can be delivered with only one measuring channel,
More informationIntrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20
Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical
More informationABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements
Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15
with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device
More informationSeries 155. Mass Flow Computers TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Mass Flow Computers Series 155 The Kurz 155 Mass Flow Computer is a versatile system transmitter that integrates the functions of flow and temperature measurement, flow totalization,
More informationOperating Manual TR600
ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN
More informationUser Guide IM/AX4CO4 Rev. K. AX413, AX430, AX433, AX436 & AX438 Single and dual input analyzers for high level conductivity
User Guide IM/AX4CO4 Rev. K AX413, AX430, AX433, AX436 & AX438 Single and dual input analyzers for high level conductivity The Company We are an established world force in the design and manufacture of
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationLINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry
LINETRAXX VMD420 Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry VMD420_D00137_02_D_XXEN/06.2016 LINETRAXX VMD420 Multi-functional
More informationStand Alone DYNAGARD SP Operation Manual
Stand Alone DYNAGARD SP Operation Manual Contents Page General Description 1 Detection Principle 1 For Your Safety 1 Design 2 Mounting 2 Mounting Position of DYNAGARD SP 2 Installation of Electrical Connections
More informationCondumax CLS16 and CLS16D
Technical Information Condumax CLS16 and CLS16D Hygienic conductivity sensor, analog or digital with Memosens technology, cell constant k = 0.1 cm -1 Application Measurement in pure and ultrapure water:
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationInstruction Manual. Aquacon Conductivity Controller / Transmitter
Instruction Manual Aquacon 000 Conductivity Controller / Transmitter 68X216853 Rev 1 /2008 Preface This manual serves to explain the use of the Aquacon 000 Series. The manual functions in two ways, firstly
More informationEKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5
More informationTurbimax CUE21 / CUE22
Technical Information Turbimax CUE1 / CUE Turbidimeter for on-line measurement Application On-line continuous monitoring of clean water: Drinking water Treated process water Your benefits Versions with
More informationfor relative humidity and temperature
1 860 1860P01 Duct sensor for relative humidity and temperature QFM651 Operating voltage AC 24 V Signal output DC 010 V for relative humidity Signal output L&S Ni 1000 (passive) for temperature Measurement
More informationConductivity Product Name Part No.
Conductivity Product Name Part No. Industrial Conductivity Cells...70-82-03-14 5000TC Torodial Conductivity Cells...70-82-03-37 Transmitter-APT2000 Contacting Conductivity...70-82-03-33 Transmitter-APT2000
More informationChlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253
Technical Information TI 214C/07/en 51502336 Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253 Transmitter for free chlorine and chlorine dioxide Liquisys S CCM 223 Due to the modularity
More informationModus Model DA General Eastern Low Differential Pressure Alarm Controller
GE Sensing & Inspection Technologies Modus Model DA General Eastern Low Differential Alarm Controller The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines
More informationDPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description
DPB52 True RMS 3-Phase, Multifunction monitoring relay Description Benefits Measuring Voltage Range. Very wide input voltage range: from 125 to 624V ( 208V 40% to 480 + 30% ). Adjustable Voltage Ranges
More informationAH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER
AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,
More informationOxygen (O2) Single-Point Gas Detection System
Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR
More informationSteam and Water Analysers
Steam and Water Analysers A Comprehensive Range for Steam and Water Analysis System (SWAS) ANALYTICAL INSTRUMENTS Energy Conservation Environment Process Efficiency www.forbesmarshall.com Steam and Water
More informationOperating Manual VMD420
Operating Manual VMD420 Voltage and frequency monitor for monitoring of 3(N)AC systems up to 0...500 V for undervoltage and overvoltage and under and overfrequency Software version: D238 V2.2x Power in
More informationDissolved Oxygen Analyzers
FEATURES DESCRIPTION The model 223 Dissolved Oxygen Transmitter measures dissolved oxygen over the range of 0 to 20mg/l or 0 to 200% saturation. The basic transmitter is available with either a 115VAC,
More informationSeries Temperature Controller Instruction Sheet
Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep
More informationDual Input Toroidal Analyzer
Instruction Sheet PN 51A-1055T/rev.H February 2006 Model 1055 SOLU COMP II Dual Input Toroidal Analyzer Model Option 1055-21-31 For additional information, please refer to the Instruction Manuals CD shipped
More informationGM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /
3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationSafety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)
Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection
More informationISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V
Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V IR1575_D00116_00_D_XXEN/05.2015 Insulation monitoring device for unearthed AC/3(N)AC systems up to 480
More informationMODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power
Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function
More informationSCHMIDT LED Measured Value Display MD Instructions for Use
SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...
More informationConcise catalogue Water-Industry
2008 Concise catalogue Water-Industry One-channel instruments to measure ph, EC, DO and free chlorine, panel and wall-mounting version. Transmitters - controllers very easy to utilize, the customer does
More informationModel AX411 Dual Input Conductivity Analyzer
AX400 Series User Guide Model AX411 Dual Input Conductivity Analyzer ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow
More informationDräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors
Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger
More informationQFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature
1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21... Use Type summary Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for relative humidity Signal output
More information4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en
Technical information TI074R/09/en 51001353 Contactor RTA421 Contactor with loop power supply for monitoring currentorvoltagesignals Application areas Plant and machine construction Panel builders Process
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...
More informationDruck DPI 705/DPI 705 IS Series
GE Sensing & Inspection Technologies 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Druck DPI 705/DPI 705 IS Series Digital Pressure
More informationRVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER
Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page
More informationitemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter
BA 104R/24/ae/10.03 itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter Operating instructions RTD TC TMT 187 TMT 188 Temperature head transmitter Safety message # Warning! Instructions and
More informationQFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature
1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Operating voltage AC 24 V / DC 13535 V Signal output DC 010 V / 420 ma for relative humidity Signal output DC 010 V / 420 ma
More informationDifferential Pressure and Flow Meter Media 5 Indicator 160 PN 40
Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids
More informationOperating Instructions Edition 02/2007
Operating Instructions Edition 02/2007 Temperature Transmitter 7NG3214 with PROFIBUS PA 7NG3215 with FOUNDATION Fieldbus sitrans Introduction 1 General safety notes 2 SITRANS T Temperature transmitter
More informationModel D12-IR. Digital Gas Transmitter...
Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact
More informationRosemount 3490 Series
Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationDIGITAL METERS Large Display Temperature Meters Instruction Manual
DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large
More informationModels AX410 and AX411 Single and Dual Input Conductivity Analyzers
AX400 Series User Guide Models AX410 and AX411 Single and Dual Input Conductivity Analyzers Incorporating Models AX450 and AX455 To Meet United States Pharmacopeia (USP 645) Regulations ABB The Company
More information1 4 DIN Dissolved Oxygen Controller
16. Warranty OAKTON warrants this controller to be free from significant deviations in material and workmanship for a period of one year from date of purchase. If repair or adjustment is necessary and
More informationDuct Temperature Sensors
1 762 1761P03 1762P01 Mounting flange AQM630 QAM21 Symaro Duct Temperature Sensors QAM2161040 QAM2171040 Active sensors for acquiring the air temperature in air ducts AC 24 V or DC 13535 V Signal output
More informationModel Q45P/R. ph/orp Monitor...
Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.
More informationDanfoss gas detection unit Type GD Heavy Duty
Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx
More informationR1000 / R1040 / R1080
R1000 / R1040 / R1080 1 Zone Temperature Controller: Heat-only Heating-off-cooling Three-point stepping DIN-Format: 96mm x 96mm / 48mm x 96mm / 96mm x 48mm Description and operating manual ELOTECH Industrieelektronik
More informationTHERMASREG TR 040 THERMASREG TR 060
THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary
More informationHYGROPHIL H process hygrometer
HYGROPHIL H 4230-10 process hygrometer Continuous humidity measurement in industrial processes. For very high demands in terms of being resistant to corrosion and dirt. Particularly suitable for cases
More information