CORRELATING COMMITTEE ON COMBUSTIBLE DUSTS

Size: px
Start display at page:

Download "CORRELATING COMMITTEE ON COMBUSTIBLE DUSTS"

Transcription

1 CORRELATING COMMITTEE ON COMBUSTIBLE DUSTS June 19-21, 2013 NFPA Headquarters 1 Batterymarch Park Quincy, MA AGENDA 1. Meeting opening, welcome members and guests, and introductions 2. Chair's remarks, Kevin Kreitman 3. Staff Liaison update (Committee Roster, schedule, Correlating Committee duties and responsibilities, and new process review) 4. NFPA 91 CMD- HAP First Draft Report a. Review and act on Public Input and First Draft b. Develop Correlating Notes and Correlating Revisions (as appropriate) see attached sections on Correlating Committees from Regulations Governing Committee Projects 5. NFPA 652 CMD-FUN First Draft Report a. Review and act on Public Input and First Draft b. Develop Correlating Notes and Correlating Revisions (as appropriate) see attached sections on Correlating Committees from Regulations Governing Committee Projects 6. Other business a. Fire Protection Research Foundation code fund projects discussion 7. Next meeting a. 484 (A14) Public Comment Closing Date is May 3, 2013 with Second Draft Meeting scheduled for June 17 18, 2013 and CC Meeting by November 8, 2013 b. 91 and 652 (F14) Public Comment Closing Date is November 15, 2013 with final date for Second Draft Meeting of TC by January 24, 2014 and CC Meeting by May 23, Adjournment

2 Address List No Phone Combustible Dusts 05/02/2013 Guy R. Colonna Kevin Kreitman Chair City of Redding Fire Department PO Box Redding, CA E 10/18/2011 Matthew J. Bujewski MJB Risk Consulting 9650 Mill Hill Lane St. Louis, MO SE 03/07/2013 John M. Cholin J. M. Cholin Consultants Inc. 101 Roosevelt Drive Oakland, NJ SE 10/18/2011 Gregory F. Creswell Titanium Metals Corporation (TIMET) 900 Hemlock Road Morgantown, PA M 10/18/2011 Scott G. Davis GexCon US 4833 Rugby Avenue, Suite 100 Bethesda, MD SE 03/07/2013 Henry L. Febo, Jr. FM Global Engineering Standards 1151 Boston-Providence Turnpike PO Box 9102 Norwood, MA I 10/18/2011 Donald Hayden Closure Systems International 7702 Woodland Drive, Suite 200 Indianapolis, IN U 08/09/2012 Mark Herrick Cargill, Inc. PO Box 9300, MS#1 Minneapolis, MN Alternate: Craig Froehling U 03/05/2012 Edward R. LaPine Aon Fire Protection Engineering Corporation 2555 East Camelback Road Suite 700 Phoenix, AZ I 10/29/2012 Jack E. Osborn Airdusco, Inc Mendenhall Road South Memphis, TN M 10/18/2011 George Petino, Jr. Hazards Research Corporation, Inc. 200 Valley Road, Suite 104 Mt. Arlington, NJ Mars Inc. Alternate: Dale C. Hansen U 10/18/2011 Bruce L. Rottner Scientific Hazard Analysis, Inc. PO Box 236 Ridgefield Park, NJ SE 10/18/2011 Bill Stevenson CV Technology, Inc Mercantile Court Jupiter, FL Alternate: Jason Krbec M 10/18/2011 Robert Wittenbarger Michelin North America 1401 Antioch Church Road Greenville, SC U 03/07/2013 1

3 Address List No Phone Combustible Dusts 05/02/2013 Guy R. Colonna Craig Froehling Alternate Cargill, Inc McGinty Road West, MS 63 Wayzata, MN : Mark Herrick U 03/05/2012 Dale C. Hansen Alternate Harrington Group, Inc Meadowbrook Parkway, Suite 250 Duluth, GA Mars Inc. : George Petino, Jr. U 03/05/2012 Jason Krbec Alternate CV Technology, Inc Mercantile Court Jupiter, FL : Bill Stevenson M 10/29/2012 Matthew I. Chibbaro Nonvoting Member US Department of Labor Occupational Safety & Health Administration 200 Constitution Ave. NW, Room N3609 Washington, DC Alternate: William R. Hamilton E 10/18/2011 Mark W. Drake Nonvoting Member Liberty Mutual Commercial Markets West 128th Street Overland Park, KS TC on Combustible Metals and Metal Dusts I 10/18/2011 Walter L. Frank Nonvoting Member Frank Risk Solutions, Inc Shallcross Avenue Wilmington, DE TC on Handling and Conveying of Dusts, Vapors, and Gases SE 8/15/2011 Paul F. Hart Nonvoting Member XL Global Asset Protection Services Martin Avenue Homewood, IL TC on Fundamentals of Combustible Dusts I 08/09/2011 Arthur P. Mattos, Jr. Nonvoting Member XL Global Asset Protection Services 3216 Tatting Road Matthews, NC TC on Wood and Cellulosic Materials Processing I 8/15/2011 Timothy J. Myers Nonvoting Member Exponent, Inc. 9 Strathmore Road Natick, MA TC on Agricultural Dusts SE 10/18/2011 Jason P. Reason Nonvoting Member Indiana Department of Labor/IOSHA 402 West Washington Street, Room W195 Indianapolis, IN E 10/18/2011 William R. Hamilton Alt. to Nonvoting Member US Department of Labor Occupational Safety & Health Administration 200 Constitution Ave. NW, Room N3609 Washington, DC : Matthew I. Chibbaro E 10/18/2011 Guy R. Colonna Staff Liaison National Fire Protection Association 1 Batterymarch Park Quincy, MA /1/2011 2

4 2014 FALL REVISION CYCLE *Public Input Dates may vary according to standards and schedules for Revision Cycles may change. Please check the NFPA Website for the most up to date information on Public Input Closing Dates and schedules at (i.e. and click on the Next Edition tab. Process Stage Process Step Dates for TC Dates for TC with CC Public Input Closing Date* 1/4/2013 1/4/2013 Final Date for TC First Draft Meeting 6/14/2013 3/15/2013 Public Input Posting of First Draft and TC Ballot 8/2/2013 4/26/2013 Stage Final date for Receipt of TC First Draft ballot 8/23/2013 5/17/2013 (First Draft) Final date for Receipt of TC First Draft ballot recirc 8/30/2013 5/24/2013 Posting of First Draft for CC Meeting 5/31/2013 Final date for CC First Draft Meeting 7/21/2013 Posting of First Draft and CC Ballot 8/2/2013 Final date for Receipt of CC First Draft ballot 8/23/2013 Final date for Receipt of CC First Draft ballot recirc 8/30/2013 Post First Draft Report for Public Comment 9/6/2013 9/6/2013 Public Comment closing date 11/15/ /15/2013 Final Date to Publish Notice of Consent Standards (Standards that 11/29/ /29/2013 received no Comments) Appeal Closing Date for Consent Standards (Standards that received 12/13/ /13/2013 no Comments) Final date for TC Second Draft Meeting 5/2/2014 1/24/2014 Comment Posting of Second Draft and TC Ballot 6/13/2014 3/7/2014 Stage Final date for Receipt of TC Second Draft ballot 7/7/2014 3/28/2014 (Second Final date for receipt of TC Second Draft ballot recirc 7/14/2014 4/4/2014 Draft) Posting of Second Draft for CC Meeting 4/11/2014 Final date for CC Second Draft Meeting 5/23/2014 Posting of Second Draft for CC Ballot 6/13/2014 Final date for Receipt of CC Second Draft ballot 7/3/2014 Final date for Receipt of CC Second Draft ballot recirc 7/11/2014 Post Second Draft Report for NITMAM Review 7/18/2014 7/18/2014 Tech Session Notice of Intent to Make a Motion (NITMAM) Closing Date 8/22/2014 8/22/2014 Preparation Posting of Certified Amending Motions (CAMs) and Consent 10/17/ /17/2014 Standards (& Issuance) Appeal Closing Date for Consent Standards 11/1/ /1/2014 SC Issuance Date for Consent Standards 11/11/ /11/2014 Tech Session Association Meeting for Standards with CAMs 6/22 25/2015 6/22 25/2015 Appeals and Appeal Closing Date for Standards with CAMs 7/15/2015 7/15/2015 Issuance SC Issuance Date for Standards with CAMs 8/20/2015 8/20/2015 Approved October 18, 2011 _ Revised_October 30, 2012

5 Regulations Governing the Development of NFPA Standards Fall 2013 and all subsequent revision cycles (excerpts pertaining to Correlating Committee and First Draft actions) 3.4 Organization and Responsibilities of Correlating Committees Organization. If the Standards Council determines that a standards development activity is of such magnitude or breadth, or for other appropriate reasons requires that a group manage and coordinate the activities of a number of Technical Committees, the Standards Council may appoint a Correlating Committee. The number of Members and the interests from which they are selected shall be determined by the Standards Council Authority. A Correlating Committee shall direct the activities of the Technical Committees that have primary responsibility for the development and revision of NFPA Standards assigned to them. The Correlating Committee shall be responsible for resolving conflicts, achieving correlation among the recommendations of the Technical Committees, correcting errors and omissions, and ensuring that the Committee activities have been conducted in accordance with these Regulations and any approved Supplemental Operating Procedures (see 3.3.8). The Correlating Committee shall have the authority to choose between alternatives presented by the Technical Committees and to write text, but only as necessary for correlation, consistency, and the correction of errors and omissions Responsibilities. The responsibilities of a Correlating Committee are: (a) Resolving conflicts within or between NFPA Standards (b) Recommending the resolution of conflicts between overlapping functions in Technical s (c) Recommending the establishment of new or the discharging of existing Technical Committees and proposing new Scopes or changes to existing Scopes of Technical Committees (d) Recommending changes in membership to obtain or improve representation on a Technical Committee (e) Correlating the scheduling of the Reports from the Technical Committees operating under its responsibility (f) Notifying a Technical Committee of its failure to comply with these Regulations or the Manual of Style for NFPA Technical Committee Documents (g) Determining whether the Technical Committee has given due consideration to all evidence presented to it in connection with the preparation of its Report, including all comments relating to negative votes (h) Establishing Supplemental Operating Procedures, if desired (see 3.3.8) (i) Performing such other or different duties as the Standards Council may from time to time assign Correlating Committee Review and Action on Public Input and the First Draft Review and Permitted Activity. Where Technical Committee activities are managed and coordinated by a Correlating Committee, the Correlating Committee shall review the First Draft as Balloted by the Technical Committees under its responsibility and take appropriate action within the limits of its authority and responsibility as set forth in and 3.4.3, in the form of Correlating Notes and Correlating Revisions Correlating Notes. In reviewing the First Draft, Correlating Committee action shall generally take the form of Correlating Notes that provide clarification and other appropriate information or that direct the responsible Technical Committee(s) to reconsider Public Input, Committee Input, or Correlating Input, conduct further review, or take further action during the preparation of the Second Draft Correlating Notes that pass Ballot shall be published in the First Draft Report and shall be linked to the part of the First Draft to which it relates. Correlating Notes shall be processed in accordance with during the Comment Stage. Correlating Notes shall be supported by at least a simple majority of the Meeting Vote for preliminary approval and shall be subject to

6 final approval through a Ballot (see ) Correlating Revisions. Where early action to promote correlation and consistency of the NFPA Standard is warranted, the Correlating Committee may also revise the First Draft by creating First Correlating Revisions, with associated Correlating Statements that delete or modify First Revisions or other text in the First Draft. To the extent that a First Correlating Revision modifies or deletes a First Revision or any portion of the First Revision, the original text of the First Revision, or affected portion thereof, shall be redesignated as a Committee Input and shall be published in the Input section of the First Draft Report along with a note indicating that the text contained in the Committee Input has been modified or deleted from the First Draft as a result of First Correlating Revision Size and Content of First Correlating Revisions. (a) An individual Correlating Revision can contain multiple changes to the Standard text, provided that these changes are contained within a contiguous portion of the Standard that is no smaller than an individual numbered or lettered section or larger than a chapter. (b) Exception for Global Revisions. Where the Correlating Committee wishes to revise a term or phrase throughout an NFPA Standard so as to achieve editorial consistency or correlation, the Committee may do so through a single Global Revision that applies the change throughout the NFPA Standard First Correlating Revisions shall be supported by at least a simple majority of the Meeting Vote for preliminary approval and shall be subject to final approval through a Ballot (see ) Preparation of First Draft for Balloting When the Correlating Committee has completed its work, NFPA Staff shall prepare the complete First Draft showing individual First Correlating Revisions and their associated Committee Statements for Balloting Prior to the Ballot, the First Draft and individual First Correlating Revisions shall be reviewed by NFPA Staff for editorial consistency and conformance with the Manual of Style for NFPA Technical Committee Documents and any required editorial changes shall be incorporated into the text of the First Draft and individual First Correlating Revisions Prior to Balloting If, in the course of editorial review, NFPA Staff make an editorial change to text that is not part of a First Correlating Revision, Staff may, if Correlating Committee review is deemed advisable, designate the affected text as a First Correlating Revision. A notice shall be attached to such a Revision indicating that it was developed by Staff for editorial purposes Correlating Committee Ballot on First Draft Balloting on Correlating Notes. (a) Any proposed Correlating Notes on the First Draft shall be submitted to a Ballot of the Correlating Committee. Approval of Correlating Notes shall be established by a three-fourths affirmative vote of the Correlating Committee. Negative votes or abstentions on specific Correlating Notes shall include the reasons for such votes. (b) Only proposed Correlating Notes that are approved by the Correlating Committee Ballot shall become Correlating Notes and be published in the First Draft Report. Correlating Notes that fail Ballot shall not be published. (c) For approved Correlating Notes, a ballot statement as indicated in (d) shall be published with its associated Correlating Notes in the First Draft Report Balloting on First Correlating Revisions. (a) Any proposed First Correlating Revisions taken on the First Draft shall be submitted to a Ballot of the Correlating Committee. Approval of First Correlating Revisions shall be established by a three-fourths affirmative vote of the Correlating Committee. Negative votes or abstentions on specific First Correlating Revisions shall include the reasons for such votes. (b) Only proposed First Correlating Revisions that are approved by the Correlating Committee Ballot shall become First Correlating Revisions and be published in the First Draft Report. First Correlating Revisions that fail Ballot shall not be published. (c) For approved First Correlating Revisions, a ballot statement as indicated

7 in (d) shall be published with their associated First Correlating Revisions in the First Draft Report. (d) Treatment of Global Revisions. Global Revisions are balloted in the same manner as other Revisions, and a Global Revision that passes Ballot is applied, as directed, throughout the Standard, independently of the results of balloting on other Revisions Technical Consideration and Action on Correlating Notes. The Technical Committee shall consider all Correlating Notes and develop a Committee Statement that provides a response. Where the Technical Committee wishes to address the Correlating Note through a change to the text, it shall develop corresponding Second Revisions. Committee Statements, in response to Correlating Notes, shall be supported by at least a simple majority of the Meeting Vote and shall not be subject to Ballot.

8 Combustible Dusts Correlating Committee Review Guidelines First Revision - Review of material o Review of Public inputs which are rejected (3.4.3 g) o Review of First Revisions which have negative votes (3.4.3 g) o Review of First Revisions which may conflict within or between NFPA Standards (3.4.3 g) o Review of First Revisions which may result in conflicts between overlapping functions in TC Scopes (3.4.3 g) o Review of Committee Inputs (3.4.3 g, h) o Committee members inputs/questions not previously addressed (3.4.3 g) o Review First Draft document layout for compliance with Manual of Style for NFPA Technical Committee Documents, and if need for establishing supplemental operating procedures (3.4.3 f, g, h) o Are there any items the CC has identified that should result in a Correlating Input to provide guidance to the Technical Committees (4.3.3; ) Second Revision - Review of material o Review of CC notes on First Revision (3.4.3 g) o Review of Public Comments which are rejected (3.4.3 g) o Review of Second Revisions which have negative votes (3.4.3 g) o Review of Second Revisions which may conflict within or between NFPA Standards (3.4.3 g) o Review of Second Revisions which may result in conflicts between overlapping functions in TC Scopes (3.4.3 g) o Review of Second Revisions which have been identified by CC member (3.4.3 g) o Review Second Draft document layout for compliance with Manual of Style for NFPA Manual of Style, and review if need exists for establishing supplemental operating procedures (3.4.3 f, g, h) o Are there any items the CC has identified that should result in a Correlating Input to provide guidance to the Technical Committees (4.3.3; ) o Is there a potential for a CC vote that would result in return of the document to the TC for further study versus forwarding the Standard to the NFPA Technical Meeting ( b)

9 Following are the Scopes for Correlating Committee and Dust Committees Combustible Dusts () This Committee shall have primary responsibility for documents on the hazard identification, prevention, control, and extinguishment of fires and explosions in the design, construction, installation, operation, and maintenance of facilities and systems used in manufacturing, processing, recycling, handling, conveying, or storing combustible particulate solids, combustible metals, or hybrid mixtures. AGRICULTURAL DUSTS (CMD-AGR) 61 This Committee shall have primary responsibility for documents on the prevention, control, and extinguishment of fire and explosions resulting from dusts produced by the processing, handling, and storage of grain, starch, food, animal feed, flour, and other agricultural products. The Technical Committee shall also be responsible for requirements relating to the protection of life and property from fire and explosion hazards at agricultural and food products facilities. Committee Responsibility Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities (NFPA 61) Document Scope 1.1 Scope * This standard shall apply to all of the following: (1) All facilities that receive, handle, process, dry, blend, use, mill, package, store, or ship dry agricultural bulk materials, their by-products, or dusts that include grains, oilseeds, agricultural seeds, legumes, sugar, flour, spices, feeds, and other related materials. (2) All facilities designed for manufacturing and handling starch, including drying, grinding, conveying, processing, packaging, and storing dry or modified starch, and dry products and dusts generated from these processes. (3) Those seed preparation and meal-handling systems of oilseed processing plants not covered by NFPA 36, Standard for Solvent Extraction Plants This standard shall not apply to oilseed extraction plants that are covered by NFPA 36, Standard for Solvent Extraction Plants. A Examples of facilities covered by this standard include, but are not limited to, bakeries, grain elevators, feed mills, flour mills, milling, corn milling (dry and wet), rice milling, dry milk products, mix plants, soybean and other oilseed preparation operations, cereal processing, snack food processing, tortilla plants, chocolate processing, pet food processing, cake mix processing, sugar refining and processing, and seed plants. Handling and Conveying of Dusts, Vapors, and Gases (CMD-HAP) 91 This Committee shall have primary responsibility for documents on the prevention, control, and extinguishment of fires and explosions in the design, construction, installation, operation, and

10 maintenance of facilities and systems processing or conveying flammable or combustible dusts, gases, vapors, and mists. Committee Responsibility Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids (NFPA 91) Standard for Prevention of Sulfur Fires and Explosions (NFPA 655) Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids (NFPA 654) Document Scope (NFPA 91) This standard provides minimum requirements for the design, construction, installation, operation, testing, and maintenance of exhaust systems for air conveying of vapors, gases, mists, and noncombustible particulate solids except as modified or amplified by other applicable NFPA standards This standard does not cover exhaust systems for conveying combustible particulate solids that are covered in other NFPA standards (see A.1.1). COMBUSTIBLE METALS (CMD-CMM) 484 This committee shall have primary responsibility for documents on safeguards against fire and explosion in the manufacturing, processing, handling, and storage of combustible metals, powders, and dusts. Committee Responsibility Standard for Combustible Metals (NFPA 484) Document Scope 1.1* Scope. This standard shall apply to the production, processing, finishing, handling, recycling, storage, and use of all metals and alloys that are in a form that is capable of combustion or explosion The procedures in Chapter 4 shall be used to determine whether a metal is in a noncombustible form Combustible Powder or Dust This standard also shall apply to operations where metal or metal alloys are subjected to processing or finishing operations that produce combustible powder or dust Operations where metal or metal alloys are subjected to processing or finishing operations that produce combustible powder or dust shall include, but shall not be limited to, machining, sawing, grinding, buffing, and polishing * Metals, metal alloy parts, and those materials, including scrap, that exhibit combustion characteristics of aluminum, alkali metals, magnesium, tantalum, titanium, or zirconium shall be subject to the requirements of the metal whose combustion characteristics they most closely match Metals and metal alloy parts and those materials, including scrap, that do not exhibit combustion characteristics of alkali metals, aluminum, magnesium, niobium, tantalum, titanium, or zirconium are subject to the requirements of Chapter 10.

11 1.1.5* This standard shall not apply to the transportation of metals in any form on public highways and waterways or by air or rail This standard shall not apply to the primary production of aluminum, magnesium, and lithium This standard shall apply to laboratories that handle, use, or store more than 1/2 lb of alkali metals or 2 lb aggregate of other combustible metals, excluding alkali metals All alkali metals and metals that are in a form that is water reactive shall be subject to this standard * If the quantity of a combustible metal listed in Table is exceeded in an occupancy, the requirements of NFPA 484 shall apply. STANDARD ON COMBUSTIBLE DUSTS (CMD-FUN) 652 This Committee shall have primary responsibility for information and documents on the management of fire and explosion hazards from combustible dusts and particulate solids Document Scope This standard shall provide the basic principles of and requirements for identifying and managing the fire and explosion hazards of combustible dusts and particulate solids. Committee Responsibility Standard on Combustible Dusts (NFPA 652) PREVENTION OF FIRE AND DUST EXPLOSIONS FROM THE MANUFACTURING, PROCESSING, AND HANDLING OF COMBUSTIBLE PARTICULATE SOLIDS (CMD- HAP) 654 This Committee shall have primary responsibility for documents on the prevention, control, and extinguishment of fires and explosions in the design, construction, installation, operation, and maintenance of facilities and systems processing or conveying flammable or combustible dusts, gases, vapors, and mists. Committee Responsibility Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids (NFPA 91) Standard for Prevention of Sulfur Fires and Explosions (NFPA 655) Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids (NFPA 654) Document Scope (NFPA 654) 1.1.1* This standard shall apply to all phases of the manufacture, processing, blending, pneumatic conveying, repackaging, and handling of combustible particulate solids or hybrid

12 mixtures, regardless of concentration or particle size, where the materials present a fire or explosion hazard This standard shall apply to systems that convey combustible particulate solids that are produced as a result of a principal or incidental activity, regardless of concentration or particle size, where the materials present a fire or explosion hazard This standard shall not apply to materials covered by the following documents, unless specifically referenced by the applicable document: (1) NFPA 30B, Code for the Manufacture and Storage of Aerosol Products (2) NFPA 61, Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Products Facilities (3) NFPA 120, Standard for Coal Preparation Plants (4) NFPA 432, Code for the Storage of Organic Peroxide Formulations (5) NFPA 480, Standard for the Storage, Handling, and Processing of Magnesium Solids and Powders (6) NFPA 481, Standard for the Production, Processing, Handling, and Storage of Titanium (7) NFPA 482, Standard for the Production, Processing, Handling, and Storage of Zirconium (8) NFPA 485, Standard for the Storage, Handling, Processing, and Use of Lithium Metal (9) NFPA 495, Explosive Materials Code (10) NFPA 651, Standard for the Machining and Finishing of Aluminum and the Production and Handling of Aluminum Powders (11) NFPA 655, Standard for Prevention of Sulfur Fires and Explosions (12) NFPA 664, Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities (13) NFPA 1124, Code for the Manufacture, Transportation, and Storage of Fireworks and Pyrotechnic Articles (14) NFPA 1125, Code for the Manufacture of Model Rocket and High Power Rocket Motors (15) NFPA 8503, Standard for Pulverized Fuel Systems In the event of a conflict between this standard and a specific occupancy standard, the specific occupancy standard requirements shall apply.

13 PREVENTION OF SULFUR FIRES AND EXPLOSIONS (CMD-HAP) 655 This Committee shall have primary responsibility for documents on the prevention, control, and extinguishment of fires and explosions in the design, construction, installation, operation, and maintenance of facilities and systems processing or conveying flammable or combustible dusts, gases, vapors, and mists. Committee Responsibility Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids (NFPA 91) Standard for Prevention of Sulfur Fires and Explosions (NFPA 655) Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids (NFPA 654) Document Scope (NFPA 655) 1.1 Scope * This standard shall apply to the crushing, grinding, or pulverizing of sulfur and to the handling of sulfur in any form This standard shall not apply to the mining of sulfur, recovery of sulfur from process streams, or transportation of sulfur. PREVENTION OF FIRES AND EXPLOSIONS IN WOOD PROCESSING AND WOODWORKING FACILITIES (CMD-WOO) 664 This Committee shall have primary responsibility for documents on the prevention, control, and extinguishment of fires and explosions in wood processing, wood working facilities and facilities that use other cellulosic materials as a substitute or additive for wood. Committee Responsibility Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities (NFPA 664)

14 Document Scope 1.1 Scope. This standard shall establish the minimum requirements for fire and explosion prevention and protection of industrial, commercial, or institutional facilities that process wood or manufacture wood products, using wood or other cellulosic fiber as a substitute for or additive to wood fiber, and that process wood, creating wood chips, particles, or dust Woodworking and wood processing facilities shall include, but are not limited to, wood flour plants, industrial woodworking plants, furniture plants, plywood plants, composite board plants, lumber mills, and production-type woodworking shops and carpentry shops that are incidental to facilities that would not otherwise fall within the purview of this standard * This standard shall apply to woodworking operations that occupy areas of more than 465 m2 (5000 ft2) or where dust-producing equipment requires an aggregate dust collection flow rate of more than 2549 m3/hr (1500 ft3/min).

Correlating Committee on Combustible Dusts (CMD-AAC)

Correlating Committee on Combustible Dusts (CMD-AAC) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org Correlating Committee on Combustible Dusts (CMD-AAC) Drury Plaza Hotel

More information

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Guy R. Colonna, PE Division Manager, NFPA Combustible Dust Symposium Detroit, MI September 20, 2011 1 Objectives

More information

TECHNICAL COMMITTEE ON FIRE CODE

TECHNICAL COMMITTEE ON FIRE CODE TECHNICAL COMMITTEE ON FIRE CODE M E M O R A N D U M TO: FROM: Technical Committee on Fire Code (FCC-AAA) Gregory Harrington, P.E., Staff Liaison DATE: February 3, 2011 SUBJECT: NFPA 1124 Amended CP#2

More information

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, 2014 9:00 AM - 5:00 PM EST Web/Teleconference Meeting 1. Welcome. George Seuss, Chair 2. Introductions and Update

More information

1. Welcome. Robert Smith, Chair. 2. Introductions and Update of Committee Roster. (attached)

1. Welcome. Robert Smith, Chair. 2. Introductions and Update of Committee Roster. (attached) TECHNICAL COMMITTEE ON WATER-COOLING TOWERS NFPA 214 (F2015) Second Draft Meeting Agenda February 17, 2014 10:00 AM - 1:00 PM EST Web/Teleconference Meeting 1. Welcome. Robert Smith, Chair 2. Introductions

More information

Technical Committee on Combustible Metals and Metal Dusts AGENDA

Technical Committee on Combustible Metals and Metal Dusts AGENDA Technical Committee on Combustible Metals and Metal Dusts AGENDA Embassy Suites Albuquerque-Hotel and Spa 1000 Woodward Place NE Albuquerque, NM 87102 February 3-5, 2015 8:00 a.m. 5:00 p.m. 1. Chair s

More information

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018) M EM O RA N D UM TO: FROM: DATE: SUBJECT: Correlating Committee on Combustible Dusts Yiu Lee, Project Administrator January 27, 2017 NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Correlating Committee on Combustible Dusts Susan

More information

Technical Committee on Fluidized Bed Boilers

Technical Committee on Fluidized Bed Boilers Technical on Fluidized Bed Boilers AGENDA Web/Teleconference 1. Chair s welcome, call to order, and opening remarks at 1:00 pm EST. 2. Self-Introduction of Members and Guests 3. Approval of Minutes from

More information

Report on Proposals F2007 Copyright, NFPA NFPA 499 Report of the Committee on

Report on Proposals F2007 Copyright, NFPA NFPA 499 Report of the Committee on Report on Proposals F2007 Copyright, NFPA NFPA 499 Report of the Committee on This list represents the membership at the time the Committee was balloted on the text of this edition. Since that time, changes

More information

M E M O R A N D U M. NFPA Technical Committee on Wood and Cellulosic Materials Processing

M E M O R A N D U M. NFPA Technical Committee on Wood and Cellulosic Materials Processing National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Wood and Cellulosic

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Merchant Vessels

More information

TECHNICAL COMMITTEE ON SOLVENT EXTRACTION PLANTS

TECHNICAL COMMITTEE ON SOLVENT EXTRACTION PLANTS TECHNICAL COMMITTEE ON SOLVENT EXTRACTION PLANTS MEMORANDUM TO: FROM: Technical Committee on Solvent Extraction Plants R. P. Benedetti DATE: May 2, 2012 SUBJECT: Agenda for Conference Call ROC Meeting

More information

Technical Committee on Combustible Metals and Metal Dusts AGENDA - NFPA 484 Second Draft Meeting

Technical Committee on Combustible Metals and Metal Dusts AGENDA - NFPA 484 Second Draft Meeting Technical Committee on Combustible Metals and Metal Dusts AGENDA - NFPA 484 Second Draft Meeting Boeing Company 1301 SW 16 th Street Renton, WA 98057 June 20-22, 2017 8:00 a.m. 5:00 p.m. 1. Chair s welcome,

More information

2016 Annual Revision Cycle Consent Document NFPA 75

2016 Annual Revision Cycle Consent Document NFPA 75 2016 Annual Revision Cycle Consent Document NFPA 75 The Committee on Electronic Computer Systems produced a Technical Committee Report that received at least one Notice of Intent to Make a Motion (NITMAM)

More information

Technical Committee on Fluidized Bed Boilers

Technical Committee on Fluidized Bed Boilers Technical Committee on Fluidized Bed Boilers AGENDA NFPA Headquarters 1 Batterymarch Park Quincy, MA 02169 1. Chair s welcome, call to order, and opening remarks at 1:00 pm EST. 2. Self-Introduction of

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Fire Code (FCC-AAA) Gregory

More information

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts Guy R. Colonna, PE Division Manager, NFPA Pellet Fuels Institute Conference Asheville, NC July 20, 2010 1 Objectives

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

Aluminum Dust Management in a Metallizing Facility

Aluminum Dust Management in a Metallizing Facility Aluminum Dust Management in a Metallizing Facility Safety and Regulatory Concerns William James Barlow, Jr., Product Development Engineer, National Accounts Division Printpack, Inc., Villa Rica, GA Overview

More information

Technical Committee on Mining Facilities First Draft Meeting - NFPA 120 and 122

Technical Committee on Mining Facilities First Draft Meeting - NFPA 120 and 122 Technical Committee on Mining Facilities First Draft Meeting - NFPA 120 and 122 Zurich Hosted 1400 America Lane Schaumburg, Illinois May 22 23, 2013 AGENDA 1. Chair Matt Bujewski calls meeting to order

More information

home smoke candles alarms electrical burns smoking medical oxygen cooking FIREFIGHTING MATCHES & LIGHTERS SPRINKLERS

home smoke candles alarms electrical burns smoking medical oxygen cooking FIREFIGHTING MATCHES & LIGHTERS SPRINKLERS FIREFIGHTING home smoke alarms REGULATIONS GOVERNING THE NFPA EDUCATIONAL MESSAGES DESK REFERENCE FOR THE FIRE SERVICE AND FIRE AND LIFE SAFETY EDUCATORS MATCHES & LIGHTERS medical oxygen cooking FIRE

More information

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS I. Introduction. This is the Motions Committee Report on Standards in the Fall 2013 Revision Cycle. The report identifies Certified

More information

Committee on NFPA 85

Committee on NFPA 85 Committee on NFPA 85 M E M O R A N D U M TO: FROM: NFPA Technical Committee on Single Burner Boilers Patti Mucci, Technical Assistant II DATE: August 5, 2009 SUBJECT: NFPA ROP Letter Ballot The ROP letter

More information

National Fire Protection Association

National Fire Protection Association National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M (AMENDMENT) TO: FROM: Technical Committee on Mercantile

More information

NFPA s Standards Development Process

NFPA s Standards Development Process NFPA s Standards Development Process Revision Cycle 104 weeks or 141 weeks Guiding Principles Due process Openness Lack of dominance Seek society s balance between: Acceptable risk Commitment of resources

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

Technical Committee on Fundamentals of Combustible Dusts (CMD-FUN)

Technical Committee on Fundamentals of Combustible Dusts (CMD-FUN) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org Technical Committee on Fundamentals of Combustible Dusts (CMD-FUN) NFPA

More information

First Revision No. 1-NFPA [ Chapter 2 ]

First Revision No. 1-NFPA [ Chapter 2 ] First Revision No. 1-NFPA 499-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this recommended practice

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Hot Work Operations

More information

TECHNICAL COMMITTEE ON WATER-COOLING TOWERS. First Draft Meeting Agenda. February 7, :00 AM - 5:00 PM EST Web/Teleconference Meeting

TECHNICAL COMMITTEE ON WATER-COOLING TOWERS. First Draft Meeting Agenda. February 7, :00 AM - 5:00 PM EST Web/Teleconference Meeting TECHNICAL COMMITTEE ON WATER-COOLING TOWERS First Draft Meeting Agenda February 7, 2014 10:00 AM - 5:00 PM EST Web/Teleconference Meeting 1. Welcome. Robert Smith, Chair 2. Introductions and Update of

More information

Subject: BSR Uniform Mechanical Code, 2015 Edition: Appeal on Proposal #333

Subject: BSR Uniform Mechanical Code, 2015 Edition: Appeal on Proposal #333 Paul Cabot Administrator National Fuel Gas Ms. Gabriella Davis Recording Secretary, IAPMO Standards Council International Association of Plumbing and Mechanical Officials (IAPMO) IAPMO Group World Headquarters

More information

NFPA Overview. International Titanium 2014 Conference Chicago Kevin L. Kreitman

NFPA Overview. International Titanium 2014 Conference Chicago Kevin L. Kreitman NFPA 484 - Overview International Titanium 2014 Conference Chicago Kevin L. Kreitman Disclaimer This presentation is for informational purposes only. In preparing and making this information available,

More information

MEMORANDUM. NFPA Technical Committee on Handling and Conveying of Dusts, Vapors, and Gases. NFPA 654 Second Draft TC FINAL Ballot Results (A2016)

MEMORANDUM. NFPA Technical Committee on Handling and Conveying of Dusts, Vapors, and Gases. NFPA 654 Second Draft TC FINAL Ballot Results (A2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Handling and Conveying

More information

Pre-First Draft Meeting Technical Committee on Wastewater Treatment Plants On line/conference Call November 20, PM EDT

Pre-First Draft Meeting Technical Committee on Wastewater Treatment Plants On line/conference Call November 20, PM EDT Pre-First Draft Meeting Technical Committee on Wastewater Treatment Plants On line/conference Call vember 20, 2012 2-4 PM EDT (1-3 PM CT; 12-2 PM MT; 11-1 PM PT) 1. Welcome-Glenn McGinley, Committee Chair

More information

M E M O R A N D U M. NFPA 1 First Draft Technical Committee FINAL Ballot Results (A2017)

M E M O R A N D U M. NFPA 1 First Draft Technical Committee FINAL Ballot Results (A2017) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Fire Code Kelly Carey,

More information

MEMORANDUM. SUBJ: NFPA 72 Proposed TIA No FINAL CC BALLOT RESULTS

MEMORANDUM. SUBJ: NFPA 72 Proposed TIA No FINAL CC BALLOT RESULTS National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: NFPA Correlating Committee on Signaling Systems for

More information

FINAL* REPORT OF THE MOTIONS COMMITTEE

FINAL* REPORT OF THE MOTIONS COMMITTEE FINAL* REPORT OF THE MOTIONS COMMITTEE ON CERTIFIED AMENDING MOTIONS FOR PRESENTATION AT THE 2012 ASSOCIATION TECHNICAL MEETING JUNE 13-14, 2012 LAS VEGAS, NEVADA I. Introduction. This is the second and

More information

Report on Comments F2006 Copyright, NFPA NFPA 560 Report of the Committee on

Report on Comments F2006 Copyright, NFPA NFPA 560 Report of the Committee on Report on Comments F2006 Copyright, NFPA NFPA 560 Report of the Committee on Nonvoting Industrial and Medical Gases Michael W. St. Clair, Chair Ostrander, OH [U] Rep. NFPA Industrial Fire Protection Section

More information

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Construction and Demolition

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Construction and Demolition National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Construction

More information

Standards Council Meeting AGENDA. Hotel Mazarin 730 Bienville Street New Orleans, LA (504) April 10-11, 2018

Standards Council Meeting AGENDA. Hotel Mazarin 730 Bienville Street New Orleans, LA (504) April 10-11, 2018 Standards Council Meeting AGENDA Hotel Mazarin 730 Bienville Street New Orleans, LA 70130 (504) 581-7300 April 10-11, 2018 18-4-1 Act on the issuance of proposed Tentative Interim Amendment (TIA) to revise

More information

NFPA Technical Committee on Fire Tests FALL 2011 ROC MEETING MINUTES

NFPA Technical Committee on Fire Tests FALL 2011 ROC MEETING MINUTES National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org NFPA Technical Committee on Fire Tests FALL 2011 ROC MEETING MINUTES 1.

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE COMMITTEE

FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE COMMITTEE FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE COMMITTEE MEMORANDUM TO: FROM: NFPA 30 Technical Committee on Storage and Warehousing of Containers and Portable Tanks R. P. Benedetti DATE: September 16, 2010 SUBJECT:

More information

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input of 280 2/6/2015 12:06 PM Public Input No. 1-NFPA 58-2013 [ Global Input ] NOTE: This public input originates from Tentative Interim Amendment 58-14-1 (TIA 1079) issued by the Standards Council on August

More information

Dust Explosions. health & environmental sciences failure analysis & prevention

Dust Explosions. health & environmental sciences failure analysis & prevention health & environmental sciences failure analysis & prevention Dust Explosions Timothy Myers 9 Strathmore Road Natick, MA 01760 tmyers@exponent.com (508) 652-8572 December 7, 2016 A leading engineering

More information

TECHNICAL COMMITTEE ON AGRICULTURAL DUSTS. NFPA 61 CMD-AGR (A2016) First Draft Meeting

TECHNICAL COMMITTEE ON AGRICULTURAL DUSTS. NFPA 61 CMD-AGR (A2016) First Draft Meeting TECHNICAL COMMITTEE ON AGRICULTURAL DUSTS NFPA 61 (A2016) First Draft Meeting Sheraton Denver Downtown Denver, Colorado August 26-28, 2014 8 AM 5 PM AGENDA 1. Meeting is called to order at 8 AM 2. Welcome

More information

MEMORANDUM. Technical Committee on Fundamentals of Combustible Dusts. NFPA 652 First Draft Technical Committee FINAL Ballot Results (A2018)

MEMORANDUM. Technical Committee on Fundamentals of Combustible Dusts. NFPA 652 First Draft Technical Committee FINAL Ballot Results (A2018) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Fundamentals of Combustible

More information

NFPA Technical Committee on Fire Tests

NFPA Technical Committee on Fire Tests National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Fire Tests Tracy

More information

TECHNICAL COMMITTEE ON HANDLING AND CONVEYING OF DUSTS, VAPORS, AND GASES NFPA 655 CMD-HAP F , AM 4 PM ET AGENDA

TECHNICAL COMMITTEE ON HANDLING AND CONVEYING OF DUSTS, VAPORS, AND GASES NFPA 655 CMD-HAP F , AM 4 PM ET AGENDA TECHNICAL COMMITTEE ON HANDLING AND CONVEYING OF DUSTS, VAPORS, AND GASES NFPA 655 CMD-HAP F2016 First Draft Web/Teleconference Meeting February 23, 2015 10 AM 4 PM ET AGENDA 1.0 Meeting is called to order

More information

Committee on NFPA 51A

Committee on NFPA 51A Committee on M E M O R A N D U M TO: FROM: NFPA Technical Committee on Industrial and Medical Gases Patti Mucci, Administrative Assistant DATE: May 6, 2010 SUBJECT: ROC Letter Ballot The ROC letter ballot

More information

Correlating Committee on Automatic Sprinkler Systems

Correlating Committee on Automatic Sprinkler Systems Correlating Committee on Automatic Sprinkler Systems M E M O R A N D U M DATE: May 14, 2014 TO: FROM: Principal and Alternate Members of the Correlating Committee on Automatic Sprinkler Systems Matt Klaus,

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 14 FROM: Kimberly Shea DATE:

More information

MEMORANDUM. Technical Committee on Board and Care Facilities. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

MEMORANDUM. Technical Committee on Board and Care Facilities. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Board and Care Facilities

More information

SC # /16/17/18/19/23/24 D#03-24

SC # /16/17/18/19/23/24 D#03-24 SC #03-7-15/16/17/18/19/23/24 D#03-24 Casey C. Grant, P.E. Secretary, Standards Council 26 July 2003 To: Interested Parties Subject: Standards Council Decision (Final): D#03-24 Standards Council Agenda

More information

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement of 1 9/22/2014 1:38 PM Second Revision No. 104-NFPA 72-2014 [ Section No. 3.3.3 ] 3.3.3 Accessible, Readily (Readily Accessible). Capable of being reached quickly for operation, renewal, or inspections

More information

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016 TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES NFPA 610 First Draft Meeting October 17-18, 2016 Westin Kansas City at Crown Center 1 East Pershing Road Kansas City, MO, 64108 Conference Call Access:

More information

MEMORANDUM. Subject: NFPA 1124 Proposed Tentative Interim Amendment (TIA) No. 1094

MEMORANDUM. Subject: NFPA 1124 Proposed Tentative Interim Amendment (TIA) No. 1094 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Pyrotechnics Elena Carroll,

More information

First Revision No. 15-NFPA [ Chapter 2 ]

First Revision No. 15-NFPA [ Chapter 2 ] Page 1 of 28 First Revision No. 15-NFPA 91-2013 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard

More information

3/20/2017. The Impact & Implications of NFPA 652 NFPA s Newest Combustible Dust Standard. Jason Reason. Jason Reason

3/20/2017. The Impact & Implications of NFPA 652 NFPA s Newest Combustible Dust Standard. Jason Reason. Jason Reason The Impact & Implications of NFPA 652 NFPA s Newest Combustible Dust Standard Jason Reason, CIH, CSP, CHMM Senior Vice President / Consultant Jason Reason Education & Certifications B.S. Industrial Hygiene

More information

12/21/2015 National Fire Protection Association Report

12/21/2015 National Fire Protection Association Report http://submittals.nfpa.org/terraviewweb/viewerpage.jsp?id=232 2012.ditamap&toc=false&draft=true 1/9 Public Comment No. 1 NFPA 232 2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents

More information

Fire Department Fees.

Fire Department Fees. Fire Department Fees. North Liberty Fire Department 25 W. Cherry St., North Liberty, IA Phone: (319) 626-5717 Fax: (319) 626-3238 Fire Department Fee Schedule Council Members, I just wanted to take a moment

More information

NATIONAL FIRE PROTECTION ASSOCIATION The leading information and knowledge resource on fire, electrical and related hazards NFPA STANDARDS DIRECTORY

NATIONAL FIRE PROTECTION ASSOCIATION The leading information and knowledge resource on fire, electrical and related hazards NFPA STANDARDS DIRECTORY NATIONAL FIRE PROTECTION ASSOCIATION The leading information and knowledge resource on fire, electrical and related hazards NFPA STANDARDS DIRECTORY 2017 2017 NFPA Standards Directory The content in the

More information

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings

More information

M E M O R A N D U M. Please do not vote negatively because of editorial errors. However, please bring such errors to my attention for action.

M E M O R A N D U M. Please do not vote negatively because of editorial errors. However, please bring such errors to my attention for action. M E M O R A N D U M TO: FROM: NFPA Technical Committee on Fire Marshal Professional Qualifications Stacey Van Zandt DATE: July 13, 2010 SUBJECT: NFPA 1037 ROP TC Letter Ballot (F2011) The ROP letter ballot

More information

MEMORANDUM. Technical Committee on Emergency Power Supplies. NFPA 111 First Draft Technical Committee FINAL Ballot Results (A2018)

MEMORANDUM. Technical Committee on Emergency Power Supplies. NFPA 111 First Draft Technical Committee FINAL Ballot Results (A2018) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Emergency Power Supplies Kelly

More information

MEETING AGENDA High Rise Building Safety Advisory Committee

MEETING AGENDA High Rise Building Safety Advisory Committee MEETING AGENDA High Rise Building Safety Advisory Committee Renaissance Blackstone Chicago 636 South Michigan Avenue, Chicago, IL 60605 May 13-14, 2014 Chicago, IL 1. Call to Order. Call the meeting to

More information

Combustible Metals & Metal Dusts Committee

Combustible Metals & Metal Dusts Committee Combustible Metals & Metal Dusts Pre-Second Draft Meeting on NFPA 484 Web-conference: http://nfpa.adobeconnect.com/nfpa484/ Call In: 1-855-747-8824, Code: 483056 January 8-10, 2013 AGENDA 1. Chair Drake

More information

Minutes of the Pre-ROP Meeting of the T/C on Protected Premises Signaling September 22-23, 2010 Indianapolis, IN

Minutes of the Pre-ROP Meeting of the T/C on Protected Premises Signaling September 22-23, 2010 Indianapolis, IN Minutes of the Pre-ROP Meeting of the T/C on Protected Premises Signaling September 22-23, 2010 Indianapolis, IN Mr. Merton Bunker, Committee Chair, called the meeting to order at 8:05 on Wednesday September

More information

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Service and Fire Protection Equipment Gregory Harrington, P.E., Staff Liaison DATE: October 1, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter

More information

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Industrial and Medical Gases

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Building Service and

More information

Report of the Committee on Makhoul (Mike) T. Kadri, Automotive and Marine Service Stations Patrick A. McLaughlin, John S. Robison, Robert L.

Report of the Committee on Makhoul (Mike) T. Kadri, Automotive and Marine Service Stations Patrick A. McLaughlin, John S. Robison, Robert L. Report of the Committee on Automotive and Marine Service Stations John S. Robison, Chair Alabama State Fire Marshal s Office, AL [E] Rep. International Fire Marshals Association E. Joseph Bocci, US Department

More information

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement 1 of 7 3/4/2016 12:02 PM Second Revision No. 5-NFPA 56-2016 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by

More information

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Helicopter Facilities

More information

2016 Fall Revision Cycle Consent Document NFPA 1000

2016 Fall Revision Cycle Consent Document NFPA 1000 2016 Fall Revision Cycle Consent Document NFPA 1000 The Committee on Accreditation and Certification for Fire Service, Public Safety, and Related Personnel to Professional Qualifications Standards, produced

More information

Committee on 51A M E M O R A N D U M. NFPA Technical Committee on Industrial and Medical Gases

Committee on 51A M E M O R A N D U M. NFPA Technical Committee on Industrial and Medical Gases Committee on 51A M E M O R A N D U M To: From: NFPA Technical Committee on Industrial and Medical Gases Patti Mucci, Administrative Assistant Date: June 14, 2010 Subject: NFPA 51A ROC Letter Ballot Circulation

More information

Public Input No. 3-NFPA [ Chapter 2 ]

Public Input No. 3-NFPA [ Chapter 2 ] Public Input No. 3-NFPA 655-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA DOCUMENTS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA DOCUMENTS

IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA DOCUMENTS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA DOCUMENTS NFPA 499 Recommended Practice for the Classification of Combustible Dusts and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas 2017 IMPORTANT NOTICES AND DISCLAIMERS

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Portable Fire Extinguishers

More information

2015 International Fire Code

2015 International Fire Code 2015 International Fire Code Study Companion ISBN: 978-1-60983-546-0 Cover Design: Publications Manager: Project Editor: Illustrator/Interior Design: Manager of Development: Ricky Razo Mary Lou Luif Greg

More information

Special Occupancy Requirements

Special Occupancy Requirements Special Occupancy Requirements CHAPTER 2 0 AVIATION FACILITIES CHAPTER 2 1 DRY CLEANING CHAPTER 2 2 COMBUSTIBLE DUST-PRODUCING OPERATIONS Special Occupancies The objective of this module is to make the

More information

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101): The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101): 1.1.1 Title. NFPA 101, Life Safety Code, shall be known as the Life Safety Code, is cited as such, and shall

More information

TECHNICAL COMMITTEE ON FIRE PUMPS

TECHNICAL COMMITTEE ON FIRE PUMPS TECHNICAL COMMITTEE ON FIRE PUMPS MEMORANDUM TO: FROM: Technical Committee on Fire Pumps Joanne Goyette, on behalf of C. Duffy / R. P. Benedetti DATE: May 2, 2011 SUBJECT: Letter Ballot on Proposals to

More information

Introductions made by the Chair, committee members, NFPA Staff Liaison, Jacqueline Wilmot and Dan Gorham of the Fire Protection Research Foundation.

Introductions made by the Chair, committee members, NFPA Staff Liaison, Jacqueline Wilmot and Dan Gorham of the Fire Protection Research Foundation. NFPA Technical Committee On Fire Hose NFPA 1961 Minutes Task Group Update Underwriters Laboratory November 15 th - 16 th 2016 Tuesday, November 15 th, 2016 Meeting called to order at 8:07 AM by Chairman

More information

NFPA 654. Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids

NFPA 654. Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids NFPA 654 Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids NFPA, 1 Batterymarch Park, Quincy, MA 02169-7471 An International

More information

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] 4.3.11.5.5 Materials within a raised floor plenum exposed to the airflow shall be (a) noncombustible or (b) exhibit a maximum flame spread index of 25

More information

NFPA Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems

NFPA Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems San Antonio, TX October 12-14, 2016 The following are the meeting minutes from the third meeting of the Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems held in San Antonio,

More information

MEMORANDUM. Technical Committee on Mercantile and Business Occupancies. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

MEMORANDUM. Technical Committee on Mercantile and Business Occupancies. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Mercantile and Business Occupancies

More information

Standards and Safety Update

Standards and Safety Update Standards and Safety Update Presented By: Michael J. Johnston Executive Director Standards and Safety, NECA Update Objectives Update on NFPA 70E and NECA Safety products Update on NECA S National Electrical

More information

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 1-NFPA 36-2013 [ Global Input ] Revise the document to eliminate the use of "Exception" text. The use of "Exception" text is inconsistent with the Manual of Style. Exception text should

More information

BUILDING/FIRE CODE REFERENCES 2006 EDITION

BUILDING/FIRE CODE REFERENCES 2006 EDITION BUILDING/FIRE CODE REFERENCES 2006 EDITION This document provides a cross reference with the International Building Code and NFPA 1/Uniform Fire The IBC references the IFC in 97 Code sections. This document

More information

Get Instant Access to ebook Nfpa 91 PDF at Our Huge Library NFPA 91 PDF. ==> Download: NFPA 91 PDF

Get Instant Access to ebook Nfpa 91 PDF at Our Huge Library NFPA 91 PDF. ==> Download: NFPA 91 PDF NFPA 91 PDF ==> Download: NFPA 91 PDF NFPA 91 PDF - Are you searching for Nfpa 91 Books? Now, you will be happy that at this time Nfpa 91 PDF is available at our online library. With our complete resources,

More information

NFPA Technical Committee on Building Systems. NFPA 900 First Draft Teleconference/Web Meeting AGENDA. Thursday, February 13, :00 a.m.

NFPA Technical Committee on Building Systems. NFPA 900 First Draft Teleconference/Web Meeting AGENDA. Thursday, February 13, :00 a.m. 1. Call to Order: NFPA Technical Committee on Building Systems NFPA 900 First Draft Teleconference/Web Meeting AGENDA Thursday, February 13, 2014 11:00 a.m. Noon EDT Online meeting link: http://nfpa.adobeconnect.com/r366m2eaxx6/

More information

REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA

REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA January 1, 2017 2016 Title 24, Part 9, California Fire Code General Information: 1. The date of these errata is for identification purposes only. See

More information

Reference Guide) 3. New Business

Reference Guide) 3. New Business NFPA 495 and NFPA 498 (F2017) Pre-First Draft Web/Teleconference Meeting October 29, 2014 http://nfpa.adobeconnect.com/r7o6jqh81rc/ 1:00 p.m. to 3:00 p.m. (Eastern Time Zone) 1. Meeting opening, introduction

More information

Combustible Dust Issues

Combustible Dust Issues Combustible Dust Issues Dust Collector Requirements J Kirt Boston IAF Programs Manager Donaldson Company, Inc. Combustible Dust Impact on Collectors Rules or Requirements Discussed by Customers What areas

More information