SUMP PUMP INSTALLATION INSTRUCTIONS MODEL

Size: px
Start display at page:

Download "SUMP PUMP INSTALLATION INSTRUCTIONS MODEL"

Transcription

1 C R N COMPANY FOR OVE ADIA AN A PROU DLY EAR 35Y É FIÈ R AN TRE C ED Ê UIS P ADIENNE DEP 2190 Dagenais Blvd. West LAVAL (QUEBEC) CANADA H7L 5X9 DE LUS 35ANS S UNE SOCIÉT TEL: FAX: info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due to rough handling. Carefully inspect your pump for damages that could cause failures. Report any damage to your carrier or your point of purchase. Please read these instructions carefully. Failure to comply to instructions and designed operation of this system, may void the warranty. NOTICE This unit have been designed to pump water only. This unit is not designed for applications involving salt water, brine or any other liquids including petroleum products. Use with salt, brine or any other liquids including petroleum products will void the warranty. ELECTRICAL CONNECTION For pumping systems using more than one pump, each pump needs to be connected to a separate dedicated circuit protected by a fuse or breaker. This way, the power supply of one pump will not stop operating if the fuse of one of the pumps burns or if the breaker of one of the pumps trips BURCAM Printed in Canada INSTALLATION INSTRUCTIONS MODEL SUMP PUMP

2 SAFETY INSTRUCTIONS: This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: A B C D CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TO ENSURE YOU COMPLY WITH THE REGULATIONS. THESE CODES HAVE BEEN DESIGNED WITH YOUR SAFETY IN MIND. BE SURE YOU COMPLY WITH THEM. WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOME ELECTRICAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH A FUSE OR A CIRCUIT BREAKER. THE MOTOR HAVE TO BE SECURELY PLUGGED INTO A PROPER GFCI ELECTRICAL OUTLET. CONSULT A LICENSED ELECTRICIAN FOR ALL WIRING. THE GROUND TERMINAL ON THE THREE PRONG PLUGS SHOULD NEVER BE REMOVED. THEY ARE SUPPLIED AND DESIGNED FOR YOUR PROTECTION. NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DO NOT ONLY UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER PLUG FROM THE RECEPTACLE. MONTHLY MANDATORY CHECK-UP : 1. Inspect the pump and the sump for any obvious condition that necessitates cleaning, correction, adjustement or repair. 2. Clear the sump and the surroundings of any paper, leaves or other debris that might clog the input openings. Remove anything that might float into the suction area. 3. Assure that the pump is secure and vertical for proper operation. 4. Assure that there is adequate clearance from any combustible materials or structure. Stored materials must be kept away from the pump. Shelves or cabinet structures must not be in close proximity over the pump. 5. Test the GFCI outlet by pressing its test switch. This should prove that the outlet is energized and will trip off to protect against a ground fault. Be sure to reset the GFCI by pressing its reset switch. 6. Lift the float to prove that the pump will start when required. (Step 8 below will test submersible pumps with enclosed floats). 7. Put the necessary pail of water in the sump to prove that any check valve present will permit effluent to flow. 8. Observe that the plumbing can carry the effluent safely out of the residence. MATERIAL REQUIRED FOR A SUBMERSIBLE SUMP PUMP APPLICATION Desired length of 1 1/2 or 1 1/4 of ABS/DWV pipe to link up the pump to the drain line. 1 only 1 1/4 check valve (350353) or (350363). Sump pit or 1 only sump basin. 1 1/4-1 1/2 stainless steel clamps (750886). ABS cement. Tools Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe ends, pipe wrench, adjustable wrench to tighten fittings. 2

3 APPLICATION This submersible sump pump is designed for a permanent sump installation. To be used in a residential cottage and farm application. CAPACITIES LPH US GPH FRICTION LOSS IN PIPE NOT INCLUDED FEATURES Stainless steel mechanical rotary seal. Thermal and overload protection. Piggy back grounded cables 115VAC, 60Hz. 1/2 HP 4.6 A, (9.2 A at start) IMPORTANT NOTICE INSTRUCTION STEPS Please note before you proceed with the installation of this product that the manufacturer s guideline has to be respected. Failure to comply may void your warranty. The following are minimum requirements in order to protect your residence from flooding. It is a small investment but it is your personal responsibility to protect your home, family and valuables. Failure to comply with the following requirements may also void your warranty: Two (2) pumps have to be installed in the sump pit. The first pump as a primary pump and the second pump as the backup unit. Burcam alarm system model has to be installed to advise you of any malfunctions. As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery powered back up pump model has to be installed to evacuate the water. Pump selection, proper and adequate installation are a must to comply with local by-laws and need to be adhered to. STEP 1 STEP 2 We recommend that you install your pump in a clean location where there is adequate room for servicing at a later date. Protection from freezing temperatures and good ventilation should be considered as well, to provide the pump an environment for long life. Do not use to pump gas or toxic fuels. This submersible sump pump is designed to pump water only. Friction losses in the discharge pipe must be taken into consideration when the horizontal offset is greater than 50 feet. The discharge pipe should be increased from 1 1/2 to 2. This will reduce friction losses and allow the pump to give maximum performance. More friction losses must also be taken into consideration when many elbows and fittings are installed in the discharge line. Each elbows and fittings must be considered as 1 feet of head. The float switch of your pump has been pre-set at the factory and does not need any adjustment. Never run the pump dry. Damage to the seal may occur. Fill pump pit or sump basin with water before turning on the power. Assuming that you have a sump pit located in your basement floor... Your sump pit must be constructed from concrete, brick, tile or more recently a sump basin made from plastic and/ or fiberglass. The minimum size of your sump pit must be 18 in diameter and no less than 25 deep. When pit is ready, proceed to next step. 3

4 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 SUMP PUMP APPLICATION (SEE DIAGRAM ON PAGE 5) At this step, you have the opportunity to install a 1 1/2 or a 1 1/4 discharge. We recommend a 1 1/2 ABS/DWV discharge. Install a check valve ( in-line 1 1/2 or /4 MNPT inlet and 1 1/4 or 1 1/2 outlet or /2 MNPT inlet and 1 1/2 or 2 outlet) over discharge pipe of your pump and secure it with stainless steel clamps or glued nipple for ABS/ DWV pipe. This check valve will allow easy access to pump, should service be required. Install and position your submersible sump pump in the centre of your sump pit or basin and ensure that there is clearance to allow the vertical float switch a free working area without obstructions (pipe, pit s wall, power cord). The float cord length is factory set and should not need adjustment. If adjustment is required, the switch cord can be shorted or lengthed. Install your discharge pipe from check valve to the point of discharge or drain. For installation over 50 feet of horizontal position discharge pipe, use a 2 pipe to reduce friction loss. We recommend that a licensed electrician be employed to do wiring. Permanently ground the motor in accordance to the electrical codes for your area. Do not use an extension cord to connect your pump to the power source. From your distribution panel to the receptacle, we recommend a wire gauge not smaller than 14 gauge. Use tape or tie wrap to fix power cords to discharge pipe. Fill the sump pit or basin with water to test the operation of your submersible sump pump. The motor should start when the water level reaches approximetely 3 over your pump. Allow the pump to go through several on-off cycle to assure satisfactory operation. If needed, see trouble shooting guide in this manual. Review your installation with typical diagram. Check all connections for leaks. MAINTENANCE Unplug the switch and pump motor power cord. Remove the pump from pit or basin. Remove trash accumulation and dirt from the pump and float switch. Be sure the float switch operates freely after cleaning. If tar or paint has been received in the pit or basin, use kerosene to remove residue from float switch or pump. Do not use strong paint solvents. Remove the screws that hold the strainer or the base to the bottom of the pump body. Pry the base off the pump body carefully. Clean the impeller and volute passage way from any debris wich may have become in contact with these parts. Again, If tar or paint has entered pump, clean with kerosene. Do not use strong paint solvents. Be sure impeller turns freely after cleaning. Check and clean away any debris wich may be clogging the suction inlet, pump discharge, check valve and discharge line. Replace screws and return sump pump to sump pit or basin and reconnect to piping. 4

5 SUMP PUMP APPLICATION STEP 3 Prepare your choice of discharge pipe size and check valve STEP 2 Sump pit 18 diameter X 25 depth STEP 6 Connect float and motor power cables STEP 7 Fill the basin and test the operation STEP 5 Install discharge pipe STEP 8 Review and check connections for leaks STEP 4 Install your pump in centre of pit REPAIR PARTS REF. PART DESCRIPTION Cable nuts (2) Motor cap Motor Oil seal Mechanical seal Impeller Pump casing Strainer Float switch Power cord Repair parts may be ordered from your authorized point of sale or from BUR-CAM PUMPS 5

6 TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Motor does not run. Switch is off position Blown fuse Tripped breaker Plug disconnected Corroded plug Low water level Thermal overcharge Defective switch/float Defective motor Improper float position Turn switch to on position Replace Reset Re-install Clean prongs Add water and verify Cool the motor Replace Replace/repair Check movement Pump does not deliver to full capacity. Jammed impeller Plugged check valve Blocked suction/inlet Discharge leak Blocked line/pipe Worn impeller Defective motor Clean Clean/replace Check for debris in pit and clean Repair Check for debris or ice Repair/replace Replace Pump does not shut off Defective switch Float obstruction Blocked suction/inlet Replace Adjust/check Check for debris in pit and clean TO THE END CONSUMER If you have any problems with the product, before advising the store, where you ve purchased the pump, please contact us at , and ask for our sales department, and they will be pleased to help you with any questions you might have, concerning your installation. 6

7 PUMPS Instructions must remain with installation BURCAM Printed in Canada ALERTS YOU before any water damage occurs from your sump or sewage tank IMPORTANT : Your Wi-Fi Water Watcher has a function to alert you in case of a loss of connectivity to our server. Nevertheless, to get the most out of your Wi-Fi Water Watcher, a back-up battery for your router and modem is required to maintain connectivity in case of a power failure. This kind of back-up system is available from all reputable computer equipment retailers. We highly recommend adding such a system to your existing computer equipment if you have not already done so. COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM.

8 Safety and supplementary information This product has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due to rough handling. Carefully inspect this product for damages that could cause failures. Report any damage to your carrier or your point of purchase. SAFETY INSTRUCTIONS This fine product that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TO ENSURE YOU COMPLY WITH THE REGULATIONS. THESE CODES HAVE BEEN DESIGNED WITH YOUR SAFETY IN MIND. BE SURE YOU COMPLY WITH THEM. WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOME ELECTRICAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH A FUSE OR A CIRCUIT BREAKER. THIS PRODUCT HAS TO BE SECURELY PLUGGED INTO A PROPER GFCI ELECTRICAL OUTLET. CONSULT A LICENSED ELECTRICIAN FOR ALL WIRING. WHEN SUPPLIED, THE GROUND TERMINAL ON A THREE-PRONG PLUG SHOULD NEVER BE REMOVED. IT IS SUPPLIED AND DESIGNED FOR YOUR PROTECTION. NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DO NOT ONLY UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER PLUG FROM THE RECEPTACLE. This product was developed to notify you when a liquid level reaches a critical point. However, it does not offer any guarantee that messages will be transmitted due to the nature of the product itself. There are several steps involved in the transmission of a message between the alarm and your smart phone including your router and your modem, your internet access, several servers, our internet access, our provider for text message transmission, your cell phone service provider, etc., as well as any other device within the transmission network between the Wi-Fi Water Watcher and your smart phone. Although all devices within the transmission network have a high degree of reliability, one of them may stop functioning due to factors that are beyond our control, which may prevent messages from being transmitted. It is your responsibility to regularly check that your product is functional. A detailed manual is available at Search for product model P.2

9 Safety and supplementary information Battery is fully charged when LED is flashing slowly.. The battery needs to be recharged when LED is flashing rapidly. Power supply is connected when LED is on. Float sensor well connected when LED is flashing slowly. When LED is flashing rapidly the float is not well connected to the device or the float is missing. Connected to Wi-Fi network when LED is on. This product does not require any internal maintenance. Opening this unit voids the warranty. On-off button. Power supply port. Reset button (Float sensor must be pointing downwards prior to reset). Wi-fi connection is reset when this button is pushed in and held down untill the two beep signal is heard. Transmission test button. Float port.. P.3

10 Quick set-up of the Wi-Fi Water Watcher. To connect the alarm controller to your router, you need a computer, a tablet or a smart phone having a Wi Fi connectivity and a Web browser installed. ** Before you begin, have your local Wi Fi name (SSID) and password handy, as well as the encryption method (normally WPA2PSK) and encryption algorithm (normally AES) of your router. ** Step 1. To connect the alarm controller to your local Wi Fi router. A. For initial set up purposes, install the alarm controller within 15 feet (5 meters) of your Wi Fi router. B. Connect the enclosed power supply to the appropriate port on the control panel at the rear of the alarm controller and then plug it into a 115V AC receptacle. C. Connect the enclosed float sensor to the appropriate port on the control panel of the alarm controller. Keep the float sensor pointing downwards. D. Push the On/Off button on the control panel. The left LED will turn on to confirm the unit is powered by the power supply. E. Wait one minute then push the RESET button on the control panel until you hear the two-beep signal. Then release the button and you will hear the two-beep signal once more. Wait ten seconds then turn off the unit by pressing the On/Off button. Wait thirty seconds then push the On/Off button again. The unit will restart with its hot spot activated. It is now ready to be connected to the Wi Fi network. F. Using a computer, a tablet, or a smart phone, connect it to the alarm controller s hot spot. This hot spot will appear on your available Wi Fi networks as WATERALARM. P.4 Select it and enter the BURCAM15 password (case sensitive all uppercase letters). You are now connected to the hot spot. G. Open your web browser and enter the web address (URL) in the address bar of your web browser to open the set-up page of the alarm controller. H. Enter the Username admin (case sensitive) and the Password admin. Then click on Log In. You now have access to the alarm controller set-up page. I. Click on Work Mode on the left menu and select STA mode, then click on Save only. Do not click on Restart or Back. J. Click on STA Setting on the left menu. Then, replace the Wi Fi name (SSID) by your local router Wi Fi name (case sensitive). You may also scan to list the available Wi Fi networks in range and select your network. Since no password is entered, click on the OK button on the warning window. Select the encryption method of your network generally WPA2PSK and the encryption algorithm generally AES and enter your Wi Fi network password in the appropriate field, then click on Save. K. Click on Restart to allow your alarm controller to connect to your Wi Fi network. L. Wait until the far right LED turns on to confirm that the alarm controller is connected to your local Wi Fi router. M. If ever the far right LED does not turn on, you have probably not selected the appropriate encryption method and/or encryption algorithm for your router. Find the correct information and re-start the process at the line D. N. To finalise the connection to your router, press the On/Off button, wait thirty seconds then push the On/Off button again. This is to confirm that the unit reconnects automatically to your Wi Fi network.

11 Step 2. To configure the system manager to receive the messages. A Go to B. Click on the Wi Fi Water Watcher set-up button. C. Enter the serial number in the appropriate field and click OK. D. When your serial number is validated, click on create your parameters. E. Choose a password that you will remember and enter it as your access code. Enter the password a second time and click on validate. F. Enter up to three addresses and three phone numbers which will receive the messages. Check the I confirm box and click on submit. G. If desired, you can return to the line 2B and enter your serial number and password to update the addresses and phone numbers at your convenience. Step 3. To test the transmissions. A. Push the test button on the control panel of the alarm controller. You will receive the test message within 2 minutes. B. Test that the float sensor is functional by lifting up the float sensor to trigger the high level alarm. Upon reception of the high level alarm message, reposition the float sensor so that it is pointing downwards and press the reset button to receive the reset confirmation message. You may reset at any time, but you will still receive the high water level message three times at five-minute intervals even after resetting the unit. You can now install the unit near the sump, sewage, or liquid container to monitor abnormally high liquid levels. Set the float sensor to turn the alarm on 1 above the highest normal liquid level of the application. YOUR INFORMATION MY SERIAL # : MY WI-FI NAME (SSID) : MY PASSWORD : ENCRYPTION METHOD : ENCRYPTION ALGORITHM:. P.5

12 Types of messages that can be received: A TRANSMISSION TEST message is sent when the test button of the control panel is pushed. A POWER SOURCE CHANGE message is sent when the power source changes from 115V to the battery back-up (if the 115V power supply stops powering the unit). A LOW BATTERY message is sent when the battery needs to be recharged. A HIGH LIQUID LEVEL message is sent when the float lifts up and triggers the alarm. This message is automatically sent a second time five minutes after the original message and a third time ten minutes after the original message. A HIGH LIQUID LEVEL REMINDER message is sent every fifteen minutes until the unit is reset. This message is only sent after the initial high liquid level message has been sent and if the unit has not been reset. A RESET CONFIRMATION message is sent when the reset button of the control panel is pushed (float sensor must be pointing downwards prior to doing the reset). A CONFIRMATION OF ONGOING COMMUNICATION message is sent monthly to advise the owner that the connection to our server is still active (on an hourly basis, the device sends a signal to our server, which monitors when this message is received). A LOSS OF COMMUNICATION message is sent when our server stops receiving the hourly signal from your device Dagenais Blvd. West Laval, Quebec, Canada H7L 5X9 TEL.: (514) FAX.: (514) TOLL FREE NUM.: info@burcam.com P.6

PUMPS COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM. Instructions must remain with installation.

PUMPS COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM. Instructions must remain with installation. 450455 PUMPS Instructions must remain with installation. 2016 BURCAM Printed in Canada 450456T.2 ALERTS YOU before any water damage occurs from your sump or sewage tank IMPORTANT : Your Wi-Fi Water Watcher

More information

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP www.burcam.com 2190 Dagenais Blvd. West LAVAL (QUEBEC) CANADA H7L 5X9 TEL: 514.337.4415 FAX: 514.337.4029 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP

MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

MODEL E

MODEL E www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP Model T00405 REPAIR PARTS REF. PART DESCRIPTION REF. PART DESCRIPTION 1 450331 Strainer 2 450332 Oil cover "O" ring 3 400447 Impeller 4 450333 Pump casing 5 400450 Oil cover 6 400449 Oil seal 7 400448

More information

»»»»»»»»»» Utility pump LAUNDRY TUB PUMPING SYSTEM. CAPACITY: 1400 US GPH HEAD OF: 10 (3m)

»»»»»»»»»» Utility pump LAUNDRY TUB PUMPING SYSTEM. CAPACITY: 1400 US GPH HEAD OF: 10 (3m) YEAR 2WARRANTY Utility pump 1/3 HP CAPACITY: 1400 US GPH HEAD OF: 10 (3m) LAUNDRY TUB PUMPING SYSTEM Automatic switch starts motor when water enters in the pump body. Pump body made of Noryl. P trap not

More information

SUPPLEMENTARY INSTRUCTIONS

SUPPLEMENTARY INSTRUCTIONS www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate

More information

Fan Air AIR EXTRACTOR & DEHUMIDIFIER SYSTEM

Fan Air AIR EXTRACTOR & DEHUMIDIFIER SYSTEM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com WWW.BURCAM.COM OPERATION & INSTALLATION GUIDE Fan Air AIR EXTRACTOR & DEHUMIDIFIER SYSTEM Your

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL Water Hero P-100 Thank you for purchasing the Water Hero P-100, which offers whole-building leak detection and water conservation monitoring. This box contains: Main Controller

More information

Water Hero P-100. P-100 Components:

Water Hero P-100. P-100 Components: Water Hero P-100 Thank you for purchasing the Water Hero P-100. The P-100 offers wholebuilding leak detection, mitigation, and water usage monitoring. P-100 Components: Main Controller Water Meter, Sensor

More information

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA Smart Smart Garage Garage Hub Hub Manual Manual For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA by Before You Start To reduce the risk of SEVERE INJURY to persons: DO NOT enable the MyQ Smart

More information

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website General/Operational Troubleshooting Guide I have an Error Code: E0 (Thermostat

More information

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 637 Louisville,

More information

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA Smart Smart Garage Garage Hub Hub Manual Manual For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA by Before You Start To reduce the risk of SEVERE INJURY to persons: DO NOT enable the MyQ

More information

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump Page 1 of 8 biohazard risk exists. Installer(s) and/or service personnel must use proper Personal Protective Equipment and follow handling procedures

More information

Lubi Submersible Condensate Removal Pumps

Lubi Submersible Condensate Removal Pumps Please read and retain these instructions for future reference. Kindly read this manual carefully before making any effort to assemble, install, operate or maintain our pumps. Please protect yourself and

More information

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6

More information

Sump Pumps Instruction Manual & Safety Warnings

Sump Pumps Instruction Manual & Safety Warnings Important Safety Instructions SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and OPERATING INSTRUCTIONS. You will need to refer to it before attempting any installation or maintenance.

More information

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 USER GUIDE PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 AB0039 FOR RESIDENTIAL USE ONLY!! MODELS SFDB-DQ, SFDB-DR AND SFDB-DS 30042509E IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

Smart Water Heater Controller

Smart Water Heater Controller Smart Water Heater Controller Installation Instructions Version 1.0 2016 1 Introduction Congratulations on the purchase of your Aquanta Smart Water Heater Controller! The Aquanta retrofittable water heater

More information

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP 2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP 8308 PUMP PARTS BREAKDOWN Ref # Part # Manf. # Descrip on 1 NEP2134 AC 81361 PUMP LID 2 NEP2135 AC 81396 PUMP LID

More information

1. Physical Installation 2. In-app Setup 3. Features 4. Troubleshooting 5. Advanced Installation Options

1. Physical Installation 2. In-app Setup 3. Features 4. Troubleshooting 5. Advanced Installation Options Spotlight Cam Mount Smart Security at Every Corner of Your Home Your new Spotlight Cam lets you extend the Ring of Security around your entire property. Now, you ll always be the first to know when someone

More information

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP 8104 MAXI-PUMP PARTS BREAKDOWN Re f # 1 2 3 4 5 6 7a 7b 8 9 10 11 12 13 14 15 16 2 Part # NEP2134 NEP2135

More information

LC Series - Light Commercial Pump Station Installation and Operation Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual LC Series - Light Commercial Pump Station Installation and Operation Manual Please keep this manual with the pump station Content Rain Bird LC Series Overview... Safety Instruction... Operation... 3 Pump

More information

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 USER GUIDE PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 AB0039 FOR RESIDENTIAL USE ONLY!! BROAN-NUTONE LLC; HARTFORD, WISCONSIN WWW.NUTONE.COM 1-888-336-3948 REGISTER YOUR PRODUCT ONLINE

More information

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters Curv-infrared.com The Smarter Way To Heat Your Home Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters Safety Precautions Important Notice To Purchaser Before

More information

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use. SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use. READ AND FOLLOW ALL INSTRUCTIONS, WARNINGS AND CAUTIONS BEFORE USING THIS EXTRACTOR Address: 777 South

More information

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMPS OPERATING & MAINTENANCE INSTRUCTIONS SUBMERSIBLE WATER PUMPS Model Nos. HIPPO-3 and 3A 6/97 Thank you for purchasing this CLARKE, HIPPO Submersible Pump. These highly efficient pumps are designed for pumping

More information

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Manufacturers of... Quality Products since 1866 95 N. Oak St. Kendallville, IN 46755 1-800-345-9422 DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST FW0771 0116 Supersedes 0415 MODEL: DATE

More information

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Clean & Clear Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS SECTION I. SECTION II. SECTION III. SECTION IV. SECTION V. SECTION

More information

Rules for Safe Operation

Rules for Safe Operation Rules for Safe Operation Important: Do not attempt to operate the CleanStation until you have read thoroughly and understand all instructions and safety rules contained in this manual. Failure to comply

More information

BEFORE OPERATING THE MACHINE: WARNING

BEFORE OPERATING THE MACHINE: WARNING BEFORE OPERATING THE MACHINE: Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this

More information

OWNER S MANUAL. Models SCU-H11, SCU-H9, SCU-H7, SCU-H5, SCU-H3

OWNER S MANUAL. Models SCU-H11, SCU-H9, SCU-H7, SCU-H5, SCU-H3 Warranty Information Maintenance Troubleshooting Operating Instructions Installation OWNER S MANUAL Models SCU-H11, SCU-H9, SCU-H7, SCU-H5, SCU-H3 DOMESTIC USE ONLY Please read this document carefully

More information

Installation manual Anna. In combination with the Smile T230. Manual PW version 2.0

Installation manual Anna. In combination with the Smile T230. Manual PW version 2.0 Installation manual Anna. In combination with the Smile T230. Manual PW version 2.0 Hello Anna. Before there were thermostats. Now there is Anna. Anna works for you and does what she is supposed to do:

More information

DAF SPOT Trace User Guide

DAF SPOT Trace User Guide DAF SPOT Trace User Guide Page 1 of 14 Contents Introduction... 4 DAF Spot Trace... 4 Spot Trace Waterproof DC Power Cable... 4 Device Identification... 4 Installation... 5 Important... 5 Placement...

More information

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS Below you will find information about your installation and what you can expect to happen next. There are also some important steps to follow to ensure

More information

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING 12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING This manual contains very important safety warnings and information. Read and save these instructions for future

More information

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps Safety Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

SAFETY OPERATION & MAINTENANCE MANUAL X-612 CARPET EXTRACTOR

SAFETY OPERATION & MAINTENANCE MANUAL X-612 CARPET EXTRACTOR SAFETY OPERATION & MAINTENANCE MANUAL X-612 CARPET EXTRACTOR W/PARTS LIST This unit is intended for commercial use. READ AND FOLLOW ALL INSTRUCTIONS, WARNINGS AND CAUTIONS BEFORE USING THIS EXTRACTOR Address:

More information

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system. Owner's Manual for household use only Please read this document carefully before installing and/or using your vacuum cleaning system. Model : Serial No : Important Safety Instructions When using an electrical

More information

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE Ambassador 20 Automatic Carpet Scrubber Model: C8420-115 C8420-240 OPERATION SERVICE PARTS CARE This manual is furnished with each new Minuteman Ambassador 20. This provides the necessary operating and

More information

VADA - Rain2Main Automatic Rainwater Controller

VADA - Rain2Main Automatic Rainwater Controller PRODUCT OVERVIEW / APPLICATION The Vada Rain2Main is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden

More information

HT-2 / 9600 Series Control Contents

HT-2 / 9600 Series Control Contents HT-2 / 9600 Series Control Contents Tools & Parts Tools Required Parts Required Error Messages 3 Flashing Dots Pressure or Flow Switch Not Activated Pressure or Flow Switch Activated Temperature Sensor

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM INSTALLATION CAUTIONS Installation must conform to all local and state plumbing codes and regulations. Please read carefully

More information

OWNER S Manual PRINTED IN CANADA 10/2009

OWNER S Manual PRINTED IN CANADA 10/2009 OWNER S Manual PRINTED IN CANADA 10/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing

More information

BACK WASH INSIDE THE SPA

BACK WASH INSIDE THE SPA BACK WASH INSIDE THE SPA Lower the temperature to 90 degrees and let the unit run approximately 10-15 minutes. This gives the heating element the chance to cool down. Now unplug the power pack Using a

More information

Operation and Maintenance Manual 120V/60HZ

Operation and Maintenance Manual 120V/60HZ Operation and Maintenance Manual 120V/60HZ GLACIER CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Contents 1.0 INTRODUCTION... 1 2.0 UNPACKING YOUR COOL-SPACE UNIT... 1 3.0 SET-UP

More information

Installation. Please keep this manual for future reference.

Installation. Please keep this manual for future reference. Installation Tecma Bathroom Anywhere Owner s and Installation Manual Please keep this manual for future reference. Read ALL these instructions before installing the Tecma Bathroom Anywhere unit. Warning

More information

FlowMark Model Mark-II-SC Installation Operation Manual. EPA Est.#: FL-1

FlowMark Model Mark-II-SC Installation Operation Manual. EPA Est.#: FL-1 flowmark FlowMark Model Mark-II-SC Installation Operation Manual EPA Est.#: 92852-FL-1 Record Information About Your System Date Purchased: Date Installed: Serial Number: Local Representative: For assistance

More information

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No: CLEAN WATER PUMP MODEL No: Hippo4A Part No: 7230535 OPERATION & MAINTENANCE INSTRUCTIONS 0807 INTRODUCTION Thank you for purchasing this CLARKE clean water pump. This highly efficient pump is designed

More information

Owner s Manual PRINTED IN CANADA 05/2009

Owner s Manual PRINTED IN CANADA 05/2009 Owner s Manual PRINTED IN CANADA 05/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing

More information

MIGHTY PRO 1/4 HP CHILLER

MIGHTY PRO 1/4 HP CHILLER 1 MIGHTY PRO 1/4 HP CHILLER FOR TANKS UP TO 170 GALLONS TOP QUALITY & HIGHLY EFFICIENT INTEGRATED DUAL STAGE THERMOSTAT 2 ASSEMBLY PARTS FRONT TOP VIEW BACK 3 SET UP INSTRUCTIONS 1. Remove chiller and

More information

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon

More information

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera* Package Content 1 x Gateway 1 x Voice Siren 1 x IP Camera* Register the Gateway via PC Create a new account at www.elro-smartalarm.com 1. Click on Create a new account 1 x PIR Motion 1 x Magnetic 1 x Remote

More information

Installation manual Anna. In combination with the Smile T. Manual PW version 2.0

Installation manual Anna. In combination with the Smile T. Manual PW version 2.0 Installation manual Anna. In combination with the Smile T. Manual PW version 2.0 Hello Anna. Before there were thermostats. Now there is Anna. Anna works for you and does what she is supposed to do: create

More information

Thanks for shopping with Improvements! Quartz Comfort Furnace Heater Item #470295

Thanks for shopping with Improvements! Quartz Comfort Furnace Heater Item #470295 Thanks for shopping with Improvements! Quartz Comfort Furnace Heater Item #470295 To order, call 1-800-642-2112 West Chester, OH 45069 Made in China 1113 If you have questions regarding this product, call

More information

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. INSTRUCTION MANUAL Model Number: WID260P Water Dispenser with Ice Maker BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. Avanti has a policy of continuous improvement on

More information

BDASV101 BDASV102 BDASV103. model

BDASV101 BDASV102 BDASV103. model BDASV101 BDASV10 BDASV103 model IMPORTANT SAFETY INSTRUCTION SAFETY GUIDELINES - DEFINITIONS It is important for you to read and understand this manual. The information it contains relates to protecting

More information

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS 30 Professional Cooling Unit Model Number: XC3000 Owner s Manual READ AND SAVE THESE INSTRUCTIONS CAUTION: Before using this product, read this manual and follow all safety rules and operating instructions.

More information

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY π H-6621 INDUSTRIAL DEHUMIDIFIER 1-800-295-5510 uline.com WARNINGS Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord if possible. Failure

More information

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat. IT801 Thermostat User s Manual The complete guide to the set up and operation of your new smart Wi-Fi thermostat. The smart Wi-Fi thermostat system learns your comfort preferences, then finds opportunities

More information

Manual for MC21A SETUP INSTRUCTIONS

Manual for MC21A SETUP INSTRUCTIONS Manual for MC21A SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel this principle

More information

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that

More information

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-022

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-022 Easy Picker Golf Products, Inc. 415 Leonard Blvd. N., Lehigh Acres, FL 33971 PH: 239-368-6600 FAX: 239-369-1579 Service: 800-982-4653 SALES: 800-641-4653 www.easypicker.com salesdept@easypicker.com INSTALLATION

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions OPERATOR S MANUAL & PARTS LIST HYBRID DRYER PDH - PDH Series Save These Instructions Tacony, Inc., All rights reserved WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING

More information

HYDROMATIC. JB-1 System Sewage Ejector Pump Package. Pump Installation and Service Manual

HYDROMATIC. JB-1 System Sewage Ejector Pump Package. Pump Installation and Service Manual Pump Installation and Service Manual HYDROMATIC JB-1 System Sewage Ejector Pump Package NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization Minor Home Repairs 1 November 4, 2017 County of Henrico Department of Community Revitalization Educate homeowners on basic technical skills that will help the homeowner understand daily operations of different

More information

D1C HP Centrifugal Grinder Pump Installation & Service Manual with Parts List. Grinder Pump for Residential and Pressure Sewer Applications

D1C HP Centrifugal Grinder Pump Installation & Service Manual with Parts List. Grinder Pump for Residential and Pressure Sewer Applications 2HP Centrifugal Grinder Pump Installation & Service Manual with Parts List D1C20-21 Grinder Pump for Residential and Pressure Sewer Applications NOTE! To the installer: Please make sure you provide this

More information

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT. OPERATOR S MANUAL & PARTS LIST HYBRID DRYER PDH - PDH Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT. Tacony, Inc., All rights reserved Save These

More information

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION AIR SERIES SYSTEM INSTALLATION MANUAL CONTENTS CONSIDERATIONS General Plumbing Component Connection 2 2 2 ILLUSTRATION Control System 3 CONFIGURATION Voltage Verification 4 CONNECTION Component Connection

More information

model No: ir20.v2 FUSE

model No: ir20.v2 FUSE InstructioNS for: model No: ir20.v2 INFRARED PARAFfIN / KEROSENE / diesel HEATER 70000Btu 230V Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Operation and Maintenance Manual 120V/60HZ

Operation and Maintenance Manual 120V/60HZ Operation and Maintenance Manual 120V/60HZ GLACIER CS5-16-VD CS5-16-VD-TB CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Operation & Maintenance Manual 60HZ Models Table of Contents:

More information

AB Can Beverage Cooler

AB Can Beverage Cooler AB-1200 126-Can Beverage Cooler OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. 2 From

More information

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use.

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use. SAFETY, OPERATION AND MAINTENANCE MANUAL MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use. READ & FOLLOW ALL INSTRUCTIONS, WARNINGS & CAUTIONS BEFORE USING THIS EXTRACTOR This

More information

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here: DISHWASHER Models DW2432 and DW2432SS Installation Manual Write Serial Number (on inner door of unit) here: Felix Storch, Inc. Summit Appliance Division 770 Garrison Avenue Bronx, New York 10474 www.summitappliance.com

More information

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3) www.dometic.com Freightliner Refrigerator Troubleshooting Guide For Before initiating troubleshooting, the following equipment is recommended: Multimeter, 20 gauge (min) wires to use as jumpers, and 12Vdc

More information

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors 1 Set Up After downloading the Weatherhub app, follow these steps: 1.1 Connect the Gateway Connect

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

INSTALLATION AND OPERATION INSTRUCTIONS FOR

INSTALLATION AND OPERATION INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-40-DEEP-XT BI-50-DEEP-XT BI-60-DEEP-XT BI-72-DEEP-XT BI-88-DEEP-XT SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly,

More information

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC PitBoss User Manual Version 1.5 10/24/2013 Copyright 2013 PumpAlarm.com, LLC www.pumpalarm.com 1 CONTENTS Introduction... 4 How Does the PitBoss Work... 4 What Comes With Your PitBoss... 5 Getting to Know

More information

If you have any problems with this product, please call BEFORE returning it to your retailer.

If you have any problems with this product, please call BEFORE returning it to your retailer. CP35 PORTABLE EVAPORATIVE COOLER USE & CARE GUIDE Read and Save These Instructions If you have any problems with this product, please call 1-800-643-8341 BEFORE returning it to your retailer. NOTICE: This

More information

QUICK PRIME INSTALLATION AND SERVICE MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #

More information

ERGOMAX 7 INSTALLATION

ERGOMAX 7 INSTALLATION ERGOMAX 7 INSTALLATION INSTALLATION MUST CONFORM TO LOCAL CODES 1. WITH HYDRONIC BOILERS All ERGOMAX 7 units must be installed vertically. Adjustable feet for levelling are provided. PRESSURE RELIEF VALVE:

More information

InstructIon Manual KrEs EQuIPMEnt stands

InstructIon Manual KrEs EQuIPMEnt stands Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP AQUATIC ECO-SYSTEMS SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE

More information

Manual update 2016 MC37/MFC3600

Manual update 2016 MC37/MFC3600 Manual update 2016 MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You

More information

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS Note: Zurn Grease Interceptors with grease recognizing sensors are efficient appliances designed to separate grease from water.

More information

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS ZECL-26-2923-BG ZECL-30-3226-BG ZECL-33-3624-BG ZECL-39-4134-BG ZECL-2939-BG INSERT-26-3825-BG INSERT-30-4026-BG INSERT-33-4230-BG

More information

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM FOR HOT KNIFE AND IMPULSE MACHINES READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING EQUIPMENT TABLE OF CONTENTS Electrical Requirements

More information

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite Preliminary Revision: 1.0 Date: 12/4/2012 Revision: 1.0 Page i OmniSite Table of Contents Table of Contents... ii Revision History... iii Notice...iv Warning...iv Limited Warranty...iv Contact Information...iv

More information

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0) 7825 flood PUMP Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0) 121 313 1122 info@hozelock.com www.hozelock.com 33713-001? 1 AUTO ON AUTO OFF 400mm 190mm 2 3 25mm 32mm 4 5 50cm 50cm

More information

Model NFF Iron, Manganese, Hydrogen Sulfide Reduction

Model NFF Iron, Manganese, Hydrogen Sulfide Reduction Super Filter Model NFF Iron, Manganese, Hydrogen Sulfide Reduction Operating and Maintenance Manual Page 1 of this manual contains operating conditions. 57055 9/07 Enjoy clean, stain-free laundry and dishes...

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

Safety, Operation and Maintenance Manual with Parts List

Safety, Operation and Maintenance Manual with Parts List Safety, Operation and Maintenance Manual with Parts List Important Information and Safety Instructions PLEASE READ BEFORE USE! 961130022-10/10-Rev1 TABLE OF CONTENTS Safety Instructions...2 Grounding Instructions...4

More information