GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

Size: px
Start display at page:

Download "GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R"

Transcription

1 GOF Indoor and Outdoor Cables Documentation VWL Version 2.2 Source Code R

2 GOF Installation Cables Cable matrix / overview Source code: R Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini- Breakout Central Loose Tube Stranded Loose Tube Central Loose Tube Stranded Loose Tube Central Loose Tube CST I-V(ZN)HH I-V(ZN=B)H I/A-DQ(ZN=B)H I/A-DQ(ZN=B)H A-DQ(ZN)B2Y A-DQ(ZN)B2Y A-D(ZN)W2Y Stranded Loose Tube CST A-DF(ZN) 2YW2Y Stranded Loose Tube ADSS A-DF(ZN) 2YQ(ZN)2Y Fiber count General Outer sheath FireRes (LSZH) FireBur (LSZH) FireBur (LSZH) FireBur (LSZH) LLDPE MDPE MDPE MDPE HDPE Sheath color green green green green black black black black black Armouring Aramid Glass yarn Glass yarn Glass yarn Glass yarn Glass yarn Corrugated steel Corrugated steel Aramid Application Laying procedure Termination Rodent Protection Tertiary cabling Building backbone Campus backbone WAN Trunking Ducts, Trays Building riser raised floor Empty tube Ducts Directly in the ground Blowing On site termination Splicing VARIOline VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

3 Colour code fibers Source code: R Fiber DIN VDE0888 Fiber colour 1 red 13 gelb w/mark per 70 mm 2 green 14 white w/mark per 70 mm 3 blue 15 grey w/mark per 70 mm 4 yellow 16 türquoise w/mark per 70 mm 5 white 17 orange w/mark per 70 mm 6 grey 18 pink w/mark per 70 mm 7 brown 19 gelb w/mark per 35 mm 8 violet 20 white w/mark per 35 mm 9 turquoise 21 grey w/mark per 35 mm 10 black 22 türquoise w/mark per 35 mm 11 orange 23 orange w/mark per 35 mm 12 pink 24 pink w/mark per 35 mm VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

4 GOF Installation Cables FO cable marking / R&Mfreenet <Sheath> <DIN> <n> x <m> <Fiber> <Category> <Spec> <Manf. Ref.> <source code> <Meter marking> Digit Description <Sheath> Outer sheath material <DIN> Cable type designation based on DIN VDE 0888 <n> <m> <Fiber> A = outdoor cable I = indoor cable V = 900µm tight buffer fibre D = loose tube with jelly filling Q = swelling tape / swell able glass yarn F = water blocked cable core Y = PVC Number of tubes if loose tube cable Number of fibers (per tube if loose tube) Fiber type ZN = glass yarn reinforcement B = non-metallic rodent protection 2Y = outer sheath PE H = outer sheath halogen free (LSZH) HH = halogen free breakout cable (LSZH) W = corrugated steel armouring 11Y = Polyurethane G50/125 = 50/125µm multimode fiber H200/230 = 200/2300 polymer cald fiber (PCF) G62.5/125 = 62.5/125µm multimode fiber P980/1000 = 980/1000 polymer optical fiber (POF) E9/125 = E9/125µm singlemode fiber <Category> Fiber category according ISO/IEC 11801:2002 <Spec> Source code <Manf. Ref.> <Meter marking> OM1 / OM2 / OM3 = multimode fiber OH1 = PCF OS1(G.652.D) = singlemode fiber OP1 = POF Single fiber specification according datasheet Manufacturer. The logic is: if MM (GOF) fibre Attenuation / window / bandwidth Example for OM3: 3.0B F500 Attenuation is 850nm and bandwidth is 1500Mhz 850nm and 500Mhz 1300nm if SM fibre Attenuation / window / chrom. dispersion Example for OS1: 0.39F3 0.25H18 Attenuation is 1310nm and Chrom. dispersion is 3ps/km and 18ps/km if PCF or POF Not applicable R for Draka Denmark Number index for the traceability Cable is produced with a meter marking VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

5 GOF Breakout Cables I- V (ZN) HH / D Source code: R Indoor cables Fiber count 2-24 Enhanced fire resistance Number code for individual breakout identification Suitable for direct connector fitting UV stabilized LSZH sheath (color green) 900 µm tight buffered fibre Aramid yarn LSZH sheath Central strength member ø 2 mm Break out unit Wrapping Ripcord 1.1 mm FireRes sheath Fiber count 2 / Nominal cable Ø (mm) Nominal weight (kg/km) Maximum tensile strength (N) during installation IEC E1 in operation IEC E1 Minimum bending radius (mm) during installation IEC E11 in operation IEC E11 Compressive strength (N/10cm) permanent IEC E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC F1 during installation minus 20 up to plus 70 IEC F1 in operation minus 20 up to plus 70 IEC F1 Heat of combustion (MJ/km) Properties in case of fire IEC IEC C IEC IEC Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 2 R R R R R R R R R R R R R R R R R R R R R R R R R R R R VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

6 GOF Mini Breakout Cables I- V (ZN=B) H / D Source code: R Indoor cables Fiber count 2-24 Good fire resistance Glass yarn strength members Suitable for direct connector fitting UV stabilized LSZH sheath (color green) 900 µm tight buffer fibre Glass yarns FireBur sheath Fiber count 2 / Nominal cable Ø (mm) Nominal weight (kg/km) 30/ Maximum tensile strength (N) during installation IEC E1 in operation IEC E1 Short time tensile strength (N) some days IEC E1 Minimum bending radius (mm) during installation IEC E11 in operation IEC E11 Compressive strength (N/10cm) permanent IEC E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC F1 during installation minus 20 up to plus 70 IEC F1 in operation minus 20 up to plus 70 IEC F1 Heat of combustion (MJ/km) 660 a) Impact (J (Nm)) IEC E4 Torsion 5 cycles ± 1 turn IEC E7 Properties in case of fire IEC IEC IEC a) Heat of combustion with 4 Fibers is 760 MJ/km Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 2 R R R R R R R R R R R R R R R R R R R R R R R R R R R VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

7 GOF Central Loose Tube Cables I/A- DQ (ZN=B) H / E Source code: R Indoor as well as outdoor use Central loose tube with 2-24 fibers Individually color coded fibers for identification Slight rodent protection through reinforced glass yarn UV stabilized LSZH sheath (color green) Central Loose Tube Swell able Glass strength member 1.0 mm FireBur Sheath Fiber count 2 to to 24 Nominal cable Ø (mm) Nominal weight (kg/km) Maximum tensile strength (N) during installation IEC E1 in operation IEC E1 Short time tensile strength (N) some days IEC E1 Minimum bending radius (mm) loaded IEC E11 unloaded IEC E11 Compressive strength (N/10cm) permanent IEC E3 Temperature range ( C) in storage minus 40 up to plus 60 IEC F1 during installation minus 30 up to plus 40 IEC F1 in operation minus 30 up to plus 60 IEC F1 Heat of combustion (MJ/km) Impact (J (Nm)) IEC E4 Torsion 5 cycles ± 1 turn IEC E7 Kink The cables do not form a kink when a IEC E10 loop is drawn together to a diameter of 100 mm Water penetration no water on free end IEC F5B Properties in case of fire IEC IEC IEC Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 4 R R R R R R R R R R R R R R R R R R R R VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

8 GOF Stranded Loose Tube Cables I/A- DQ (ZN=B) H / N Source code: R Indoor as well as outdoor use Fiber count (stranded loose tube) Excellent mechanical properties Water tight thanks to swelling tape Slight rodent protection through reinforced glass yarn UV stabilized LSZH sheath (color green) Ripcord ø 2.5 mm FRP strength member ø 2.3 mm loose tubes with jelly filling Swelling tape Glass yarn reinforcement 1.5 mm green FireBur sheath Fiber count Nominal cable Ø (mm) 11 ± ± ± ± 0.5 Nominal weight (kg/km) Maximum tensile strength (N) during installation > 4800 > 4800 > 4800 > 4800 IEC E1 in operation > 3400 > 3400 > 3400 > 3400 IEC E1 Minimum bending radius (mm) loaded IEC E11 unloaded IEC E11 Compressive strength (N/10cm) permanent IEC E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC F1 during installation minus 40 up to plus 70 IEC F1 in operation minus 40 up to plus 60 IEC F1 Heat of combustion (MJ/km) Impact (J (Nm)) IEC E4 Torsion 5 cycles ± 1 turn IEC E7 Kink The cables do not form a kink when a IEC E10 loop is drawn together to a diameter 12 times the cable nominal diameter Water penetration no water on free end IEC F5B Properties in case of fire IEC IEC IEC Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x x x x x x VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

9 GOF Central Loose Tube Cables Rodent Protection A- DQ (ZN) B2Y / E Source code: R Outdoor cables Central loose tube with 2-24 fibers Individually color coded fibers for identification Glass yarn rodent protection UV stabilized LLDPE sheath (color black) Central Loose Tube Swell able Glass fibre yarns 1.2 mm black LLDPE sheath Fiber count 2 to to 24 Nominal cable Ø (mm) Nominal weight (kg/km) Maximum tensile strength (N) during installation IEC E1 in operation IEC E1 Short time tensile strength (N) some days IEC E1 Minimum bending radius (mm) loaded IEC E11 unloaded IEC E11 Compressive strength (N/10cm) permanent IEC E3 Temperature range ( C) in storage minus 40 up to plus 60 IEC F1 during installation minus 15 up to plus 40 IEC F1 in operation minus 30 up to plus 60 IEC F1 Impact (J (Nm)) IEC E4 Torsion 5 cycles ± 1 turn IEC E7 Kink The cables do not form a kink when a IEC E10 loop is drawn together to a diameter of 200 mm Water penetration no water on free end IEC F5B Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 4 R R R R R R R R R R R R R R R R R R R R VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

10 GOF Stranded Loose Tube Cables Rodent Protection A- DQ (ZN) B2Y / H Source code: R Outdoor cables Fiber count (stranded loose tube) Excellent mechanical properties Water tight thanks to swelling tape Glass yarn rodent protection UV stabilized MDPE sheath (color black) Ripcord ø 2.5 mm FRP strength member ø 2.3 mm loose tubes with jelly filling Swelling tape Glass yarn reinforcement 1.5 mm black MDPE sheath Fiber count Nominal cable Ø (mm) 11 ± ± ± ± 0.5 Nominal weight (kg/km) Maximum tensile strength (N) during installation > 4800 > 4800 > 4800 > 4800 IEC E1 in operation > 3400 > 3400 > 3400 > 3400 IEC E1 Minimum bending radius (mm) loaded IEC E11 unloaded IEC E11 Compressive strength (N/10cm) permanent IEC E3 Temperature range ( C) in storage minus 40 up to plus 60 IEC F1 during installation minus 40 up to plus 60 IEC F1 in operation minus 40 up to plus 60 IEC F1 Impact (J (Nm)) IEC E4 Torsion 5 cycles ± 1 turn IEC E7 Kink The cables do not form a kink when a IEC E10 loop is drawn together to a diameter 12 times the cable nominal diameter Water penetration no water on free end IEC F5B Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x x x x x x VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

11 GOF Central Loose Tube Cables Steel-Armored A- D (ZN) W2Y / E Source code: R Outdoor cable for application in harsh conditions Central loose tube with 2-24 fibers Individually color coded fibers for identification Reinforced rodent protection with corrugated steel CST UV stabilized MDPE sheath (color black) Fibres Central UNI tube Strength members mm corrugated steel tape 1.5 mm black MDPE sheath Fiber count 2 to to 24 Nominal cable Ø (mm) Nominal weight (kg/km) Maximum tensile strength (N) during installation IEC E1 in operation IEC E1 Minimum bending radius (mm) loaded IEC E11 unloaded IEC E11 Compressive strength (N/10cm) permanent IEC E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC F1 during installation minus 40 up to plus 70 IEC F1 in operation minus 40 up to plus 70 IEC F1 Impact (J (Nm)) IEC E4 Torsion 5 cycles ± 1 turn IEC E7 Kink The cables do not form a kink when a loop is drawn together to a diameter of 100 mm IEC E10 Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

12 GOF Stranded Loose Tube Cables Steel-Armored A- DF (ZN) 2YW2Y / I Source code: R Outdoor cable for direct ground installations Fiber count 6-96 (stranded loose tube) Water tight cable core Reinforced rodent protection with corrugated steel CST UV stabilized MDPE sheath (color black) ø 2.5 mm FRP strength member ø 2.3 mm loose tubes with jelly filling Jelly filling Polyester wrapping tape 1.3 mm black MDPE sheath Corrugated steel as rodent protection 1.5 mm black MDPE sheath Fiber count 8 to to 96 Nominal cable Ø (mm) Nominal weight (kg/km) Maximum tensile strength (N) during installation IEC E1 in operation IEC E1 Minimum bending radius (mm) loaded IEC E11 unloaded IEC E11 Compressive strength (N/10cm) permanent IEC E3 Temperature range ( C) in storage minus 60 up to plus 60 IEC F1 during installation minus 30 up to plus 60 IEC F1 in operation minus 60 up to plus 70 IEC F1 Impact (J (Nm)) IEC E4 Torsion 5 cycles ± 1 turn IEC E7 Kink The cables do not form a kink when a IEC E10 loop is drawn together to a diameter 12 times the cable nominal diameter Water penetration no water on free end (core only) IEC F5B Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x 12 R R R R x 12 R R R R x 12 R R R R x 12 R R R R x 12 R R R R VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

13 GOF Stranded Loose Tube Cables Aerial ADSS A- DF (ZN) 2Y Q (ZN) 2Y / O04A Source code: R Dielectric aerial cables ADSS Fiber count 6-96 (stranded loose tube) Water tight cable core Suitable for all standard span equipment High-voltage resistance of up to 132kV UV resistant HDPE sheath (color black) ø 3.0 mm FRP rod ø 2.8 mm loose tubes Jelly filling Polyester wrapping tape 1.3 mm black inner PE sheath Swelling tape Aramid strength member Black outer PE sheath Fiber count / loose tubes 4 to 72 / 6 4 to 96 / 8 Nominal cable Ø (mm) Nominal weight (kg/km) Maximum tensile strength (N) during installation IEC E1 in operation IEC E1 Cable breaking strength UTS (N) > > (IEC E1) Cable stiffness EA (kn) (IEC E1) Minimum bending radius (mm) loaded IEC E11 unloaded IEC E11 Compressive strength (N/10cm) permanent IEC E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC F1 during installation minus 40 up to plus 70 IEC F1 in operation minus 40 up to plus 70 IEC F1 Impact (J (Nm)) IEC E4 Torsion 1/m 5 times IEC E7 Coefficient of thermal expansion 6.2 x x 10-6 Water penetration no water on free end IEC F5 Stringing example for 250 m span External loading for 250 m span and 2% (=5 m) initial sag Number of optical units in cable (Fiber count) Initial cable load without external load (N) Sag with external load (m) Cable load with external load (N) 90 km/h (25 m/s) wind load 6 ( 4 to 72) (4 to 96) km/h 50 m/s) wind load 6 ( 4 to 72) a) 8 (4 to 96) a) 1 kg/m ice load 6 ( 4 to 72) (4 to 96) kg/m ice load 6 ( 4 to 72) (4 to 96) a) The dynamic tensile strength may be used as maximum acceptable tension in this case Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x x x x x VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

14 GOF Installation Cables Sheathing material / B FireRes The FireRes sheathing material is a high performance state-of-the-art LSZH (Low Smoke Zero Halogen) material. The FireRes material is primary used where a very high resistance towards fire is needed. While the FireRes material implement improvements of Draka Comteq s well known multi purpose concept regarding performance in case of fire, the resistance towards the outdoor environment is retained: The FireRes material is UV resistant, and water resistant. The UV resistance is achieved using a selected type of hindered amine light stabilizer (HALS). Thus a long lifetime even in open air is assured. The FireRes material is non- toxic, non-corrosive and do not contain any halogens that could cause damage to equipment or the environments. Further in case of fire it generates only extremely low amount of smoke. The FireRes material fulfils all relevant international and national standards for this class of sheathing material, among them: EN :2002 VDE 0207 part 24, type HM2 BS type LTS1 and LTS2 Cables made with our FireRes sheathing material is self-extinguishing and generally fulfils IEC C. The FireRes material is used as part of the A.F.R. Technology to achieve fire resistance for PyroSafe cables. Typical properties Property Result Standard Density (kg/m 3 ) 1.6 ASTM D792 Tensile strength and elongation at break (MPa) Tensile strength: 11 Elongation: 170 % Tensile strength and elongation at break after ageing 7 days at 100 C (MPa) Change in tensile strength and elongation at break after 7 days at 23 C in ASTM oil no. 2 Change in tensile strength and elongation at break after 4 hours at 70 C in ASTM oil no. 2 (%) Change in tensile strength and elongation at break after 4 hours at 70 C in SAE 20 Oil (%) Change in tensile strength and elongation at break after 7 days at 23 C in Diesel (%) Tensile strength: 13 Elongation: 120 % Tensile strength: none Elongation: none Tensile strength: -20 Elongation: +10 Tensile strength: -25 Elongation: +15 Tensile strength: -35 Elongation: -20 IEC EN IEC EN IEC IEC IEC IEC Hot pressure at 80 C (%) 35 IEC Oxygen Index (%) 45 ISO Flammability temperature index ( C) 330 ISO Smoke density Pass IEC Halogen acid gas evolution None IEC Corrosively of gases (µs/cm) Pass: Conductivity 7.5 IEC (requirement < 100); PH = 5,5 (requirement ph > 3.5) Toxicity index 0.4 NES 713 VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

15 GOF Installation Cables Sheathing material / B FireBur The FireBur Low Smoke Zero Halogen material is produced from PE-copolymers and silicon elastomer with chalk as fire retardant filler. This sheathing compound is used for cables that are installed as indoor/outdoor cables, due to its very low water absorption. The cables made with this compound can be used outdoor installation in ducts (also flooded with water) as well as for direct burial. The FireBur sheathing material is UV stabilized using a selected type of hindered amine light stabilizer (HALS). Thus a long lifetime even in the open air is assured. Cables made with this material are self-extinguishing and fulfils IEC The material fulfils the requirements of: EN :2002 VDE0207 part 24 (HM5) Typical properties Property Result Standard Density (kg/m 3 ) 1.2 ASTM D792 Tensile strength and elongation at break (MPa) Tensile strength: 11 Elongation: > 400 % IEC EN Water absorption after 10 days at 70 C (mg/cm 3 ) 0.11 IEC Flexural modulus (MPa) 205 ISO 178 Change in tensile strength and elongation at break after ageing 10 days at 100 C (%) UV and humility aging 240 days (20 hours UV light at 60 C and 4 hours damp heath at 50 C each day) (%) Acid and base resistance (28 days at 23 C) change at break: (%) HCL (37 %) NaCO 3 (ph 8) NH3 (10 %; PH 10 11) Acetic acid (20 %) Change in tensile strength and elongation at break after 4 hours at 70 C in ASTM oil no. 2 (%) Fluid resistance (24h at 49 C) change at break (%) Diesel Hydraulic oil Mil 5606 Fluid resistance (14 days at 23 C) change at break (%) Petrol Acetone Solvent resistance (14 days at 23 C) weight change (%) Iso Octane Kerosene, paraffin Ethanol Acetone 20 IEC EN Change in tensile strength: -9 Draka Change in elongation: -16 Tensile strength / Elongation -6 / -7-4 / -6-9 / -3-6 / -4 Tensile strength: -20 Elongation: -3 Tensile strength / Elongation -73 / / -41 Tensile strength / Elongation -41 / / -7 Small IEC Hot pressure at 80 C (%) 25 IEC LOI (%) 32 BS 2782: Method 141:1986 Smoke density Pass IEC Smoke corrosively (µs/cm) Pass: Conductivity 1.5 IEC (requirement < 100); ph = 5.3 (requirement ph > 3.5) Heath of combustion (MJ/dm 3 ) 28 - Toxicity index 1.5 NES 713 VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

16 GOF Installation Cables Sheathing material / B LLDPE, black This is the alternative PE material for cables for outdoor use. The material is UV stabilised using 2.5 ± 0.5 % carbon black and have excellent weathering resistance. The LLDPE material is used for UNI tube cables and when specified according to customer request. The LDPE meets the requirements of a number of national and international standards: ISO 1872-PE, KCHL, 18 - D003 ANSI C 8.35 ASTM D : Type I, Class C, Cat 5, grade J3, E5 BS C, TS1 DIN VDE 0207 type 2YM2 NF C The LLDPE fulfils the requirements of IEC (test according to IEC 811) MDDPE, black This is the standard sheathing material for cables for outdoor use. The material is UV stabilised with using 2.5 ± 0.5 % carbon black. It has excellent weathering resistance. The MDPE has very good physical properties such as: Excellent abrasion resistance, high hardness, low dielectric constant and outstanding oxidation resistance. Compared with HDPE the MDPE has better resistance to stress cracking. Compared to LDPE the MDPE has a higher strength. The MDPE meets the requirements of a number of national and international standards: ISO 1872-PE, KGC, 40 - G200, C ASTM D : Type II, Class C, Cat 5 BS C The MDPE fulfils the requirements of IEC (test according to IEC 811) Corrugated steel tape armouring Corrugated steel tape armouring is used as rodent protection and as additional mechanical protection for outdoor cables for direct burial and for installation along railways and into sewers where the risk for rodent attack is high. Cables with corrugated steel tape and LDPE or HDPE jacket fulfils the requirements of: REA PE 90 (USA) As well as the requirements of several Railway administrations: Among them Banestyrelsen (Denmark), SNCF and RATP (France), BR (Great Britain). The steel tape is corrosion protected with a layer of chromium on both sides. The steel tape fulfils the requirements of: EN : 1989 ASTM A The standard thickness of the steel tape is mm ± mm. Upon request tapes with a thickness of mm may be supplied. There is a polymer film on both sides of the steel tape. The nominal thickness of the polymer film is mm. The purpose of the polymer film is to ensure good adhesion between tape and outer (LDPE or MDPE) jacket and make the bonding of the overlap possible. The adhesion between steel tape and a polyethylene sheath is fulfilling the requirements of REA PE-90. A common trade name for this material is Zetabon. The steel tape is corrugated and folded over the cable core or an inner jacket. On top of the steel tape is extruded an outer polymer heath. Aramid yarns Aramid yarns are used as strength member for cables with tight buffered fibres, some cables with semi tight fibres and for UNI tube cable. Aramid yarns are also used in loose tube cables with central strength member as additional tensile reinforcement. There are no international or national standards for Aramid yarns. The most common trade names for Aramid yarns are Twaron and Kevlar. The tensile strength requirement for the cable determines the amount of Aramid yarn to be used. Glass yarns Glass yarns in the form of roving s are used as alternative strength member for UNI tube cables. Glass yarns are also used in loose tube cables with central strength member as additional tensile reinforcement. Thick layers of glaziers have appeared to be a good rodent protection scheme, however not as effective as steel armouring. VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

17 GOF Multi Mode Fiber 50/125 µm (OM3) / C General information This fibre is a graded-index multimode fibre optimised for 10 Gb/s transmission speeds. It has a 50 µm core diameter and a 125 µm cladding diameter. The fibre is designed for use at 850, but can also be used at 1300 nm. The fibre is compliant with all relevant network standards. Range for 1000BASE SX: 1000 m Range for 10GBASE S: 300 m Specification Standards and norm Core Coating Optical properties Dimensional and mechanical properties This fibre fulfils the requirements of: IEC ; Category A1a.2; EN ; Category A1a.2; ITU Recommendation G.651 TIA/EIA-492AAAC Testing methods are in accordance with the following standards: IEC XX:2002 EN XX:2002 FOTP-220 (DMD) The core is germanium doped. When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them are: EN :2002 category OM3. ISO/IEC 11801:2002 category OM3. IEEE with amendment 802.3ae Dual layer UV curable acrylate, type DLPC9. The coating offers excellent stable stripping performance, and a unique high and stable value for the dynamic stress corrosion coefficient. This gives a greatly improved mechanical protection of the fibre when used in harsh environments. Attenuation (of cable with fibres): Bandwidth (OFL): At 850 nm: 3.0 db/km At 850 nm: 1500 MHz km At 1300 nm: 1.0 db/km At 1300 nm: 500 MHz km Fibre attenuation (for reference only) Effective Modal Bandwidth: At 850 nm: 2.5 db/km At 850 nm 2000 MHz km At 1300 nm: 0.7 db/km Numerical aperture: ± In homogeneity of OTDR trace for any two 1000 metre fibre lengths: Max.: 0.2 db/km. Note: Effective Modal Bandwidth is assured by means of differential mode delay (DMD) measurement as specified in IEC Group index of refraction: At 850 nm At 1300 nm: Core diameter (µm) 50 ± 2.5 IEC/EN Cladding diameter (µm) ± 1.0 IEC/EN Cladding non-circularity (%) 1.0 IEC/EN Core non-circularity (%) 5 IEC/EN Core-cladding concentricity error (µm) 1.5 IEC/EN Primary coating diameter - uncoloured (µm) 242 ± 7.0 IEC/EN Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN Primary coating non-circularity (%) 5 IEC/EN Primary coating-cladding concentricity error (µm) 10 IEC/EN Proof stress level (GPa) 0.7 ( 1 %) IEC/EN Typical average strip force (N) 1.7 IEC/EN Strip force (peak) (N) 1.3 F peak.strip 8.9 IEC/EN VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

18 GOF Multi Mode Fiber 62.5/125 µm (OM1) / C General information This fibre is a graded-index multimode fibre suitable for transmission speeds of up to 10 Gb/s. It has a 62.5 µm core diameter and a 125 µm cladding diameter. The fibre is designed for use at 850 and/or 1300 nm. This fibre is suitable for use in premises wiring application like LAN s with video, data and or voice services using LED, VCSEL and Fabry- Perot laser sources. The fibre is compliant with all relevant network standards. Specification Standards and norm Core Coating Optical properties This fibre fulfils the requirements of: IEC Category A1b; EN : type A1b TIA/EIA-492AAAA Testing methods are in accordance with the following standards: IEC XX:2002 EN XX:2002 When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them are: EN :2002 category OM1. ISO/IEC 11801:2002 category OM1 IEEE with amendment 802.3ae ANSI/TIA/EIA-568-B ANSI X IEC IBM Fibre Optic Channel Links; ESCON The core is germanium doped. Dual layer UV curable acrylate, type DLPC9. The coating offers excellent stable stripping performance, and a unique high and stable value for the dynamic stress corrosion coefficient. This gives a greatly improved mechanical protection of the fibre when used in harsh environments. Attenuation (of cable with fibres): Numerical aperture: ± At 850 nm: 3.2 db/km In homogeneity of OTDR trace for any two At 1300 nm: 1.0 db/km 1000 metre fibre lengths: Max.: 0.2 db/km. Bandwidth (OFL): At 850 nm: At 1300 nm: Dimensional and mechanical properties 200 MHz km 600 MHz km Group index of refraction: At 850 nm At 1300 nm: Core diameter (µm) 62.5 ± 2.5 IEC/EN Cladding diameter (µm) 125 ± 1.0 IEC/EN Cladding non-circularity (%) 1 IEC/EN Core non-circularity (%) 5 IEC/EN Core-cladding concentricity error (µm) 1.5 IEC/EN Primary coating diameter - uncoloured (µm) 242 ± 7.0 IEC/EN Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN Primary coating non-circularity (%) 5 IEC/EN Primary coating-cladding concentricity error (µm) 10.0 IEC/EN Proof stress level (GPa) 0.7 ( 1 %) IEC/EN Typical average strip force (N) 1.7 IEC/EN Strip force (peak) (N) 1.3 F peak.strip 8.9 IEC/EN VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

19 GOF Multi Mode Fiber 50/125 µm (OM2) / C General information This fibre is a graded-index multimode fibre suitable for transmission speeds of up to 10 Gb/s. It has a 50 µm core diameter and a 125 µm cladding diameter. The fibre is designed for use at 850 and/or 1300 nm. This fibre is suitable for use in premises wiring application like LAN s with video, data and or voice services using LED, VCSEL and Fabry- Perot laser sources. The fibre is compliant with all relevant network standards. Specification Standards and norm Core Coating Optical properties This fibre fulfils the requirements of: IEC Category A1a; EN : type A1a ITU Recommendation G.651 TIA/EIA-492AAAB Testing methods are in accordance with the following standards: IEC XX:2002 EN XX:2002 When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them are: EN :2002 category OM2. ISO/IEC 11801:2002 category OM2 IEEE with amendment 802.3ae ANSI/TIA/EIA-568.B This fibre may be used as an alternative for 62.5 µm fibre according to: ANSI X and IEC The core is germanium doped. Dual layer UV curable acrylate, type DLPC9. The coating offers excellent stable stripping performance, and a unique high and stable value for the dynamic stress corrosion coefficient. This gives a greatly improved mechanical protection of the fibre when used in harsh environments. Attenuation (of cable with fibres): Numerical aperture: ± At 850 nm: 2.7 db/km In homogeneity of OTDR trace for any two At 1300 nm: 0.8 db/km 1000 metre fibre lengths: Max.: 0.2 db/km. Bandwidth (OFL): At 850 nm: At 1300 nm: Dimensional and mechanical properties 600 MHz km 1200 MHz km Group index of refraction: At 850 nm At 1300 nm: Core diameter (µm) 50 ± 2.5 IEC/EN Cladding diameter (µm) 125 ± 1.0 IEC/EN Cladding non-circularity (%) 1.0 IEC/EN Core non-circularity (%) 5 IEC/EN Core-cladding concentricity error (µm) 1.5 IEC/EN Primary coating diameter - uncoloured (µm) 242 ± 0.7 IEC/EN Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN Primary coating non-circularity (%) 5 IEC/EN Primary coating-cladding concentricity error (µm) 10 IEC/EN Proof stress level (GPa) 0.7 ( 1 %) IEC/EN Typical average strip force (N) 1.7 IEC/EN Strip force (peak) (N) 1.3 F peak.strip 8.9 IEC/EN VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

20 GOF Single Mode Fiber 9/125 µm (OS1, G.652.D) / C03e General information This enhanced Singlemode fibre provides improved performance across the entire 1260 nm to 1625 nm wavelength spectrum due to its low attenuation in 1383 nm the water-peak region. The fibre design is matched cladding. Specification Standards and norm Core Coating Optical properties Dimensional and mechanical properties This fibre fulfils the requirements of: IEC Category B.1.3 EN : Class B1.3 ITU Recommendation G.652.D The older ITU designations A, B and C are also fulfilled. When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them is: EN : 2002, cat. OS1 + OS2 ISO/IEC 11801: 2002, cat. OS1 + OS2 IEEE incl ae Testing methods are in accordance with the following standards: IEC XX: 2002 EN XX: 2002 The core is germanium doped. The fibre coating is dual layer UV curable acrylate. The fibre is coated using Draka Comteq s proprietary high quality coating systems. Attenuation (of cable with fibres): In the range 1310 nm nm: 0.39 db/km At 1550 nm: 0.25 db/km In homogeneity of OTDR trace for any two 1000 metre fibre lengths Max.: 0.1 db/km Group index of refraction: At 1310 / 1550 / 1625 nm Cladding diameter (µm) ± 0.7 IEC/EN Cladding non-circularity (%) 0.7 IEC/EN Core (MFD) non-circularity (%) 6 IEC/EN Core (MDF) -cladding concentricity error (µm) 0.5 IEC/EN Primary coating diameter - uncoloured (µm) 242 ± 7 IEC/EN Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN Primary coating non-circularity (%) 5 IEC/EN Primary coating-cladding concentricity error (µm) 12.0 IEC/EN Proof stress level (GPa) 0.7 ( 1 %) IEC/EN Strip force (peak) (N) 1.0 Fpeak.strip 8.9 IEC/EN Chromatic dispersion coefficient: In the interval 1285 nm 1330 nm (ps/km nm) At 1550 nm (ps/km nm) At 1625 nm (ps/km nm) Zero dispersion wavelength, λ 0 (nm) Zero dispersion slope (ps/(nm 2 km)) Cut-off wavelength (λ c nm) Cut-off wavelength (λ cc nm) Mode field diameter at 1310 nm (µm) Mode field diameter at 1550 nm (µm) Macrobending loss at 1550 nm, 100 turns on a ø 60 mm mandrel (db) ± High limit: 1330 Low limit: ± ± 0.5 IEC/EN IEC/EN IEC/EN IEC/EN Polarisation mode dispersion (PMD) coefficient, cabled (ps/ km) 0.5 IEC/EN PMD Q Link Design Value (ps/ km) 0.2 IEC/EN VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

21 GOF Cabling Standards ISO/IEC 11801:2002 Fiber optic categories The category defines the performance of a cabling component components to verify the compliance components to design a link/channel values for performance comparison Multimode fiber 850nm 1300nm category core - Ø db/km Mhz km launch db/km Mhz km launch OM1 50µm & 62.5µm over filled over filled OM2 50µm & 62.5µm over filled over filled over filled OM3 50µm over filled restricted Singlemode fiber 1310nm 1550nm category core - Ø db/km Mhz km db/km Mhz km OS1 9µm 1.00 N.A 1.00 N.A Fiber optic classes The class defines end to end performance of a link its supporting cabling design of networking equipment values for certification of the installation Channel attenuation limits Class OF-300 channel supporting application over a min. length of 300m Class OF-500 channel supporting application over a min. length of 500m Class OF-2000 channel supporting application over a min. length of 2000m Note: Multimode Singlemode 850nm 1300nm 1310nm 1550nm 2.55dB 1.95dB 1.80dB 1.80dB 3.25dB 2.25dB 2.00dB 2.00dB 8.50dB 4.50dB 3.50dB 3.50dB The total values include 1.5dB for connecting hardware. Additional connectors and splices may be used if the power budget of the application allows. Models of vertical (backbone) and horizontal optical fiber cabling In order to accommodate increase quantities of mated connections and splices used within a channel of a given class, the total length of the channel may have to be reduced to accommodate the additional attenuation. Spliced combined Direct combined Patched combined VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

22 GOF Ethernet Applications Matrix ISO/IEC 11801:2002 / IEEE 802.3xx Applications according ISO/IEC 11801:2002 and EN (informative) Multimode Fast Ethernet 100Base-FX Gigabit Ethernet 1000Base-SX/LX 10Gbit Ethernet 10GBase-S 10Gbit Ethernet 10GBase-LX4 850nm 1300nm 850nm 1300nm 850nm 1300nm 850nm 1300nm OM1 N.A OF ) OF-500 N.A N.A N.A OF-300 OM2 N.A OF-2000 OF-500 OF-500 N.A N.A N.A OF-300 OM3 N.A OF-2000 OF-500 OF-500 OF-300 N.A N.A OF-300 Singlemode Gigabit Ethernet 1000Base-LX 10Gbit Ethernet 10GBase-LX4 10Gbit Ethernet 10GBase-L 10Gbit Ethernet 10GBase-E 1310nm 1550nm 1310nm 1550nm 1310nm 1550nm 1310nm 1550nm OS1 OF-2000 N.A OF-2000 N.A OF-2000 N.A N.A OF ) Maximum Length (Channel) according IEEE 802.3z (275m) Standardized applications according IEEE 802.3xx 62.5/125 (OM1) 50/125 (OM2) 50/125 (OM3) Note: 9/125 (OS1) Multimode Fast Ethernet 100Base-FX Gigabit Ethernet 1000Base-SX/LX 10Gbit Ethernet 10GBase-S 10Gbit Ethernet 10GBase-LX4 850nm 1300nm 850nm 1300nm 850nm 1300nm 850nm 1300nm Max. Length (m) N.A N.A N.A 300 Max. IL (db) N.A N.A N.A 2.0 Max. Length (m) N.A N.A N.A 300 Max. IL (db) N.A N.A N.A 2.0 Max. Length (m) N.A N.A N.A N.A Max. IL (db) N.A N.A N.A N.A The total values include 1.5 db for connecting hardware. Additional connectors and splices may be used if the power budget of the application allows. Singlemode Max. Length (m) Max. IL (db) Gigabit Ethernet 1000Base-LX 1310n m 10Gbit Ethernet 10GBase-LX4 10Gbit Ethernet 10GBase-L 10Gbit Ethernet 10GBase-E 1550nm 1310nm 1550nm 1310nm 1550nm 1310nm 1550nm N.A N.A N.A N.A N.A 6.2 N.A 6.2 N.A N.A 10.9 VWL v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M GOF Indoor and Outdoor Cables Documentation VWL 064.503 Version 1.1 Source Code M GOF Installation Cables Cable matrix / overview Source code M Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini-

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,

More information

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13. GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description

More information

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4

More information

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable

More information

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information. GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04

More information

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm). GCDG Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

HELKAMA. Optical Fibre Cables

HELKAMA. Optical Fibre Cables 1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre

More information

Duct Cable GYTS-144B1.3

Duct Cable GYTS-144B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits GBRD Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 24 36 48 60 72 62.5/125-OM1 GBRD124 GBRD136 GBRD148 GBRD160

More information

Ø 1000 * 588 mm 50 kg

Ø 1000 * 588 mm 50 kg GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3 VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright

More information

Fibre Optic Cable. Catalogue.

Fibre Optic Cable. Catalogue. Fibre Optic Cable Catalogue www.fibrefab.com About The FibreFab Group FibreFab Established in 1992, FibreFab is a leading provider of fibre optic connectivity products used in data communications and Telecommunication

More information

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1

More information

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSA Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 62.5/125-OM1

More information

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx fibrewave About Us Prysmian is a global market leader in optical cables, supplying a major part of the world s optical cable needs. With a strong heritage of highly advanced R&D, Prysmian is at the leading

More information

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:

More information

Fiber Optic Distribution Cables (6-144 Fibers)

Fiber Optic Distribution Cables (6-144 Fibers) 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are

More information

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003 Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone

More information

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET Optic Backbone Distribution Cables 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: TE

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

Fibre Specification Standards

Fibre Specification Standards Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair

More information

Fibre optic media options and trends

Fibre optic media options and trends Fibre optic media options and trends Presented by D Stockton & P Lascelles of Miniflex Ltd, branded as m2fx 23 February 2012 1 Contents Cable constructs Indoor/outdoor LSZH Armouring Micro Bends Singlemode,

More information

industry solutions: military

industry solutions: military industry solutions: military MC industry Solutions: Military A tradition of leadership in technology, product performance for military applications Optical Cable Corporation is a leading manufacturer of

More information

SPECIAL ELECTRICAL AND OPTICAL CABLES

SPECIAL ELECTRICAL AND OPTICAL CABLES SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD INTERIM EUROPEAN I-ETS 300 644 TELECOMMUNICATION June 1997 STANDARD Source: ETSI TC-TM Reference: DI/TM-01021 ICS: 33.020 Key words: Fibre, cable, optical, transmission Transmission and Multiplexing (TM);

More information

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing

More information

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION 13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION This specification is property of SEC and subject to change or modification

More information

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 90 TKF developed from a cable producer to a leading

More information

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T Translated English of Chinese Standard: YD/T1447-2013 www.chinesestandard.net Sales@ChineseStandard.net COMMUNICATION INDUSTRY STANDARD OF THE PEOPLE S REPUBLIC OF CHINA YD ICS 33.180.10 M 33 Replacing

More information

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT) TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes the following: 1. 50/125-micrometer, optical fiber cabling. 2. Cable connecting hardware, termination panels,

More information

STANDARD CONFORMANCE

STANDARD CONFORMANCE STANDARD CONFORMANCE IEC 60331-11, Tests for electric cables under fire conditions- Circuit integrity- Fire alone at a flame temperature of at least 750C IEC 60331-21, Tests for electric cables under fire

More information

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre. Specification No.CSC-131/R-1/DH//UH/P&D/2016-17 Technical Specifications for 24 Fiber/48 Fiber Unarmoured Underground Fibre Optic Cabling Issue Month:June-2016 (CSC Amendment date 14.06.2016) Common Specification

More information

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Hands-On Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Certification Course Description This Hands-On course is customized to give Technicians the confidence and skills to maintain Fiber

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

Fiber Optics for Todays Industry Applications

Fiber Optics for Todays Industry Applications Hands-On Fiber Optics for Todays Industry Applications (A Non-Telephone Company Course) Course Description This Hands-On course is designed to provide technicians with a practical understanding and Hands-On

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. Special Provision No. 683S01 December 2017 1. SCOPE This Special Provision covers

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. 3.4 TESTING OF FIBER OPTICS CABLING A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. B. General: In the event

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE Publication # ICEA S-104-696 Second Edition March 2013 2013 by ICEA INSULATED CABLE ENGINEERS ASSOCIATION, Inc. STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER

More information

Fibre (TIA) Field Test Specification

Fibre (TIA) Field Test Specification This document has been prepared to aid consultants or engineers in developing contractual specifications covering the testing of duplex fibre optic cabling installations. It is offered as a general guide.

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

CATEGORY 6A FTP RJ45 SOLUTION

CATEGORY 6A FTP RJ45 SOLUTION CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing Hands-On Splicing, Termination & Testing BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information

More information

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves STANDARD TUBE COLOR ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves TECHNICAL DATA SHEET Revision Number. 1 Last Edited 24. juli 2018 The ZH-2X Heat Shrinkable Wire Markers are made of halogen

More information

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE ANSI/ICEA S-104-696-2001 STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE Publication S-104-696 First Edition - September 2001 Published By Insulated Cable Engineers Association, Inc. Post Office Box 1568

More information

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD INTRODUCTION Work Smart FIA STAND OUT FROM THE CROWD 14th May 2002, Bisham Abbey Mike Gilmore 2002 Fibreoptic Industry Association Work Smart www.it-cabling.com www.e-readybuilding.com PO Box MT65, LEEDS,

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Product Specification CAT 6 UNSHIELDED PATCH CORDS Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT

More information

Fiber Optic Patch Cord and Pigtails

Fiber Optic Patch Cord and Pigtails Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable

More information

Detection of Solvents using a Distributed Fibre Optic Sensor

Detection of Solvents using a Distributed Fibre Optic Sensor Detection of Solvents using a Distributed Fibre Optic Sensor Alistair MacLean, Chris Moran, Walter Johnstone, Brian Culshaw, Dan Marsh, Paul Parker. A fibre optic sensor that is capable of distributed

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

ENHANCED FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

Hands-On CAT 5/6 & Fiber Optic Installer

Hands-On CAT 5/6 & Fiber Optic Installer Hands-On BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information regarding BICSI please visit

More information

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide

More information

Basic Professional Fiber Optic Installation

Basic Professional Fiber Optic Installation Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:

More information

MT-RJ Optical Fiber System Field Testing

MT-RJ Optical Fiber System Field Testing MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

FIRE PERFORMANCE CABLE

FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product Product Description PolyOne is a global polymer solutions provider with the ability to meet regulatory and product specifications globally and offer the widest range of polymer-specific specialty colorant

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

Clearlite Photonic Fibers

Clearlite Photonic Fibers Clearlite Photonic Fibers Fiber Name Operating Wavelength MFD at Operating Wavelength Beat Length at Operating WL Clad/Coating Diameter Order by Part Number TruePhase 980 Micro TruePhase 980 400 TruePhase

More information

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Workshop format The Workshop is going to start with three short lecture style power

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*

More information

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Wire and Cable. For more information on these Tyco Electronics products, visit the following website: 26 Wire and Cable Raychem High Performance Wire and Cable....26-2 to 26-4 Madison Cable Products...................26-5 to 26-7 Reference the following cables in Section 15 of this catalog: Premises Networking

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION CLC/TS 50430 SPECIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION February 2005 ICS 33.180.10 English version Optical fibre cables Gas pipe cables Family specification for cables to

More information

Fibre Optic Basics FIA Summer Seminar 2014

Fibre Optic Basics FIA Summer Seminar 2014 Fibre Optic Basics FIA Summer Seminar 2014 Andrew Cole Theory Basics Characteristics of Light What is Light? An electromagnetic wave, which like other waves, has a frequency (f), velocity (v) and a wavelength

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information

Cable technology for highest safety requirements

Cable technology for highest safety requirements Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,

More information

Certified Fibre Optic Specialist - Testing

Certified Fibre Optic Specialist - Testing Certified Fibre Optic Specialist - Testing COURSE DESCRIPTION: This training program is designed to introduce the student to the process of fibre optic network testing. It is intended for those looking

More information

Product Catalogue. External Management

Product Catalogue. External Management Product Catalogue External Management version 2017 Empowering businesses through innovative network solutions. We have been pushing boundaries and providing innovative products and solutions to clients

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information