IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Size: px
Start display at page:

Download "IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements"

Transcription

1 ExTR Reference Number...: ExTR Free Reference Number...: Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR /00 Stig André Norheim Arne Hortman Date of issue...: IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements Ex Testing Laboratory (ExTL)...: Address...: Applicant s name...: Address...: Nemko AS Gaustadalléen 30, P.O.Box 73 Blindern, NO-0314 Oslo, Norway Kongsberg Maritime AS Haakon VII s gate 4, NO-7041 Trondheim, Norway Standard...: Test procedure...: IEC :2007, 5 th Edition IECEx System Test Report Form Number...: ExTR _5D (released ) Instructions for Intended Use of Ex Test Report: An Ex Test Report provides a clause-by-clause documentation of the initial evaluation and testing that verified compliance of an item or product with an IEC Ex standard. This Ex Test Report is part of an ExTR package that may include other Ex Test Report, Addendum, National Differences and Partial Testing documents, along with a single ExTR Cover. An Ex Test Report is to be compiled and reviewed by the ExTL. The Issuing ExCB indicates final approval of the Ex Test Report as part of the overall ExTR package on the associated ExTR Cover. Copyright 2011 International Electrotechnical Commission System for Certification to Standards Relating to Equipment for use in Explosive Atmospheres (IECEx System), Geneva, Switzerland. All rights reserved. This blank publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEx System is acknowledged as copyright owner and source of the material. The IECEx system takes no responsibility for, and will not assume liability for, damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Possible test case verdicts: - test case does not apply to the test item... :N / A - test item does meet the requirement... : General remarks: The test results presented in this Ex Test Report relate only to the item or product tested. "(see Attachment #)" refers to additional information appended to this document. "(see appended table)" refers to a table appended to this document. Throughout this document, a point. is used as the decimal separator. The technical content of this Ex Test Report shall not be reproduced except in full without the written approval of the Issuing ExCB and ExTL. TRF No. ExTR _5D Page 1 of 13

2 IEC SCOPE 2 NORMATIVE REFERENCES 3 TERMS AND DEFINITIONS 4 APPARATUS GROUPING AND TEMPERATURE CLASSIFICATION 4.1 Group I 4.2 Group II Ex ia IIC T4 4.3 Group III 4.4 Equipment for a particular explosive atmosphere IIC 5 TEMPERATURES 5.1 Environmental influences Ambient temperatures Tamb= -40 C to +85 C External source of heating or cooling No additional that exceeds the ambient range. 5.2 Service temperature Internal heating is negligibly small. 5.3 Maximum surface temperature Determination of maximum surface temperature Limitation of maximum surface temperature The equipment is classified T4 based on the limiting value 200 C which applies to components < 10 cm 2 and > 20mm 2 According to IEC Group I electrical equipment Group II electrical equipment T Group III electrical equipment Maximum surface temperature determined without a dust layer Maximum surface temperature with respect to dust layers TRF No. ExTR _5D Page 2 of 13

3 5.3.3 Small component temperature for Group I or Group II electrical equipment According to IEC REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT 6.1 General Radar level sensor. 6.2 Mechanical strength of equipment No additional requirements. 6.3 Opening times Not applicable to IEC Circulating currents No circulating currents. 6.5 Gasket retention Not related to the safety concept in IEC Electromagnetic and ultrasonic energy radiating equipment Radar radiation less than 2W Radio frequency sources Radar radiation less than 2W Lasers or other continuous wave sources Not used Ultrasonic sources Not used. 7 NON-METALLIC ENCLOSURES AND NON-METALLIC PARTS OF ENCLOSURES 7.1 General Applicability Metal enclosure Specification of materials Metal enclosure Plastic materials Metal enclosure Elastomeric materials Metal enclosure. 7.2 Thermal endurance Tests for thermal endurance Metal enclosure Material selection Metal enclosure. 7.3 Resistance to light Metal enclosure. 7.4 Electrostatic charges on external non-metallic materials Applicability Metal enclosure. TRF No. ExTR _5D Page 3 of 13

4 7.4.2 Avoidance of a build-up of electrostatic charge on Group I or Group II electrical equipment Avoidance of a build-up of electrostatic charge on equipment for Group III Metal enclosure. Metal enclosure. 7.5 Threaded holes Metal enclosure. 8 METALLIC ENCLOSURES AND METALLIC PARTS OF ENCLOSURES 8.1 Material Composition Group I Group II Material of the enclosure is Stainless Steel AISI Group III 8.2 Threaded Holes Metric threads. 9 FASTENERS 9.1 General 9.2 Special fasteners 9.3 Holes for special fasteners Thread engagement Tolerance and clearance Hexagon socket set screw 10 INTERLOCKING DEVICES 11 BUSHINGS 12 MATERIALS USED FOR CEMENTING 13 EX COMPONENTS 13.1 General 13.2 Mounting TRF No. ExTR _5D Page 4 of 13

5 IEC Internal Mounting 13.4 External Mounting 14 CONNECTION FACILITIES AND TERMINAL COMPARTMENTS 14.1 General 14.2 Termination compartment 14.3 Type of protection 14.4 Creepage and clearance 15 CONNECTION FACILITIES FOR EARTHING OR BONDING CONDUCTORS 15.1 Equipment requiring earthing Internal External 15.2 Equipment not requiring earthing 15.3 Size of conductor connection 15.4 Protection against corrosion 15.5 Secureness of electrical connections 16 ENTRIES INTO ENCLOSURES 16.1 General Type of protection Ex ia 16.2 Identification of entries Type of protection Ex ia 16.3 Cable glands Type of protection Ex ia 16.4 Blanking elements TRF No. ExTR _5D Page 5 of 13

6 16.5 Temperature at branching point and entry point 16.6 Electrostatic charges of cable sheaths 17 SUPPLEMENTARY REQUIREMENTS FOR ROTATING ELECTRICAL MACHINES 17.1 Fans and fan hoods No fans used Ventilation openings for external fans 17.3 Construction and mounting of the ventilation systems 17.4 Clearances for the ventilating systems 17.5 Materials for external fans and fan hoods 17.6 Equipotential bonding conductors 18 SUPPLEMENTARY REQUIREMENTS FOR SWITCHGEAR 18.1 Flammable dielectric 18.2 Disconnectors 18.3 Group I Provisions for locking 18.4 Doors and covers 19 SUPPLEMENTARY REQUIREMENTS FOR FUSES 20 SUPPLEMENTARY REQUIREMENTS FOR PLUGS, SOCKETS OUTLETS AND CONNECTORS 20.1 Interlocking Explosive gas atmospheres Explosive dust atmospheres TRF No. ExTR _5D Page 6 of 13

7 20.2 Energized plugs 21 SUPPLEMENTARY REQUIREMENTS FOR LUMINAIRES 21.1 General 21.2 Covers for luminaires of EPL Gb or EPL Db 21.3 Covers for luminaires of EPL Gc or EPL Dc 21.4 Special lamps 22 SUPPLEMENTARY REQUIREMENTS FOR CAPLIGHTS AND HANDLIGHTS 22.1 Group I caplights 22.2 Group II and Group II caplights and handlights 23 APPARATUS INCORPORATING CELLS AND BATTERIES 23.1 General No battery Batteries 23.3 Cell types 23.4 Cells in a battery 23.5 Ratings of batteries 23.6 Interchangeability 23.7 Charging of primary batteries 23.8 Leakage 23.9 Connections Orientation TRF No. ExTR _5D Page 7 of 13

8 23.11 Replacement of cells or batteries Replaceable battery pack 24 DOCUMENTATION The documents submitted by the manufacturer give a full and correct specification of the safety aspects of the electrical apparatus. Documents listed in the Appendix to the test report. 25 COMPLIANCE OF PROTOTYPE OR SAMPLE WITH DOCUMENTS 26 TYPE TESTS 26.1 General Each test conducted on the equipment was conducted on the apparatus in the most unfavourable manner and according to the requirements in IEC Test configuration Configuration of the electrical equipment considered to be the most unfavourable Tests in explosive test mixtures Physical testing was not carried out Tests of enclosures Order of tests Metallic enclosures, metallic parts of enclosures and glass of parts of enclosures Non-metallic enclosures or non-metallic parts of enclosures Not applicable for this Ex ia equipment. Not applicable for this Ex ia equipment Group I electrical equipment Not applicable for this Ex ia equipment Group II and Group III electrical equipment Not applicable for this Ex ia equipment Resistance to impact Not applicable for this Ex ia equipment Drop test Not applicable for this Ex ia equipment Acceptance criteria Not applicable for this Ex ia equipment Degree of protection (IP) by enclosures Test procedure Not applicable for this Ex ia equipment Acceptance criteria Not applicable for this Ex ia equipment. TRF No. ExTR _5D Page 8 of 13

9 26.5 Thermal tests Temperature measurement General Specification in the appendix into IEC for results Service temperature Maximum surface temperature Maximum surface temperature T4 (135 C) Maximum ambient temperature specified Ta = +85 C Thermal shock test Excluded by IEC Small component ignition test (Group I and Group II) General Not utilized Procedure Acceptance criteria Not utilized Torque test for bushings Test procedure Excluded by IEC Acceptance criteria Excluded by IEC Non-metallic enclosures or non-metallic parts of enclosures General Excluded by IEC Test temperatures Excluded by IEC Thermal endurance to heat Excluded by IEC Thermal endurance to cold Excluded by IEC Resistance to light Test procedure Excluded by IEC Acceptance criteria Excluded by IEC Resistance to chemical agents for Group I electrical equipment Excluded by IEC Earth continuity Excluded by IEC Surface resistance test of parts of parts of enclosures of nonmetallic materials Enclosure of stainless steel AISI Charging tests Introduction TRF No. ExTR _5D Page 9 of 13

10 Principle of the test Samples and test apparatus Ambient conditions Conditioning Determination of the most efficient charging method Method A: Rubbing with a pure polyamide cloth Method B: Rubbing with a cotton cloth Method C: Charging by influence with a d.c. highvoltage power supply Assessment of discharge Measurement of capacitance Test procedure Enclosure of stainless steel AISI Acceptance criteria 27 Routine tests No specific for this equipment. 28 MANUFACTURER'S RESPONSIBILITY 28.1 Conformity with the documentation This concerns the manufacturer s responsibility. Declaration of Conformity Certificate The certificate relate to Ex equipment Responsibility for marking Marked according to Clause MARKING Metal sign /engraved. Is resistant to chemical and mechanical influence Location Outside on the main part General The marking include the following: a) name of the manufacturer Kongsberg b) type identification GLA-100/3 c) Implemented on the marking label. d) IECEx NEM X e) Symbol X used due to specific conditions of use f) Ex ia IIC T4 Ta= -40 C to +85 C g) - TRF No. ExTR _5D Page 10 of 13

11 IEC Ex marking for explosive gas atmospheres Ex ia IIC T4 Ta= -45 C to +85 C 29.4 Ex marking for explosive dust atmospheres 29.5 Combined types of protection 29.6 Multiple types of protection 29.7 Ga using two independent Gb types of protection 29.8 Ex components 29.9 Small equipment and small Ex components Extremely small equipment and extremely small Ex components Warning markings Alternate marking of equipment protection levels (EPLs) Alternate marking of type of protection for explosive gas atmospheres Alternate marking of type of protection for explosive dust atmospheres Cells and batteries 30 INSTRUCTIONS 30.1 General Conformity is checked by inspection. Manuals: GLA100/3 Radar Tank Gauge no.: P- GLA100.3/CE and safety instructions no Cells and batteries Annex A (Normative) SUPPLEMENTARY REQUIREMENTS FOR CABLE GLANDS A.1 General TRF No. ExTR _5D Page 11 of 13

12 IEC A.2 Constructional requirements A.2.1 Cable sealing A.2.2 Filling compounds A.2.3 Clamping A General A A.2.4 Group II or Group III cable glands Lead-in of cable A Sharp edges A Point of entry A.2.5 Released by a tool A.2.6 Fixing A.2.7 Degree of protection A.3 Type tests A.3.1 Tests of clamping of non-armoured and braided cables A A A Cable glands with clamping by the sealing ring Cable glands with clamping by the filling compound Cable glands with clamping by means of a clamping device A Tensile test A Mechanical strength A.3.2 Tests of clamping of armoured cables A Tests of clamping where the armourings are clamped by a device within the gland A Tensile test A Mechanical strength A A.3.3 A.3.4 Tests of clamping where the armourings are not clamped by a device within the gland Type test for resistance to impact Test for degree of protection (IP) of cable glands A.4 Marking A.4.1 Marking of cable glands A.4.2 Marking of cable sealing rings Annex B (Normative) Table B.1 Clauses with which Ex components shall comply TRF No. ExTR _5D Page 12 of 13

13 Measurement Section, including Additional Narrative Remarks (as deemed applicable) TRF No. ExTR _5D Page 13 of 13

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 60079.0:2012 IEC 60079-0, Ed. 6.0 (2011) AS/NZS 60079.0:2012 Australian/New Zealand Standard Explosive atmospheres Part 0: Equipment General requirements AS/NZS 60079.0:2012 This Joint Australian/New

More information

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES, FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. ON FLOW MONITOR, GPE3000 SERIES, REPORT NO. TRA-015825-33-00A ExTR Reference No. TRA-015825-33-00A

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-0 Edition 3.1 2000-06 Edition 3:1998 consolidated with amendment 1:2000 Electrical apparatus for explosive gas atmospheres Part 0: General requirements IEC 2000 Copyright

More information

TEST REPORT XMT W/ATEX SHENZHEN CARY TECHNOLOGY CO,.LTD. LED Explosion Flood Luminaire

TEST REPORT XMT W/ATEX SHENZHEN CARY TECHNOLOGY CO,.LTD. LED Explosion Flood Luminaire TEST REORT Report Reference No. Applicant: SHENZHEN CARY TECHNOLOGY CO,.LTD Address: Sample Name: Model: Test Type: Building 1, No.29 Industrial West Zone, Makan Road, Xili, Nanshan, Shenzhen, China LED

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx

More information

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Peter Thurnherr Shanghai thuba Electric Co. Ltd.,

More information

Survey of electrical equipment installed in hazardous areas on tankers

Survey of electrical equipment installed in hazardous areas on tankers (June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on

More information

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 Compliance with EN60079-15: 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 RJ11FTVX series: rugged and sealed RJ11/12 connectors Report Prepared by : Amphenol Socapex

More information

Electrical Installations Design, Selection, Erection and Inspection

Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance Test Report issued under the responsibility of: SGS- CSTC TEST REORT Safety of household and similar electrical appliances art 2: articular requirements for massage appliance Report Reference No....: GZES100800181503

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-7 Edition 5.0 2015-06 Explosive atmospheres Part 7: Equipment protection by increased safety ''e'' INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 29.260.20 ISBN 978-2-8322-2710-7

More information

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection Skip to main content Skip to primary navigation Home Home About this portal Latest updates Menu Print Save Email Resource detail Citations AS/NZS 60079.14:2009 Explosive atmospheres - Part 14: Electrical

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements Test Report issued under the responsibility of: TEST REPORT IEC 60825-1 Safety of laser products - Part 1: Equipment classification and requirements Report Number.... : 102254161MPK-001L Date of issue...

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-1 Fourth edition 2001-02 Electrical apparatus for explosive gas atmospheres Part 1: Flameproof enclosures "d" Matériel électrique pour atmosphères explosives gazeuses Partie

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

AS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard

AS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard AS/NZS 60079.7:2016 (IEC 60079-7, Ed 5.0:2015, IDT) Australian/New Zealand Standard Explosive atmospheres Part 7: Equipment protection by increased safety e Superseding AS/NZS 60079.7:2006 AS/NZS 60079.7:2016

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

AS/NZS :2015. Explosive atmospheres AS/NZS :2015. Part 1: Equipment protection by flameproof enclosures d

AS/NZS :2015. Explosive atmospheres AS/NZS :2015. Part 1: Equipment protection by flameproof enclosures d AS/NZS 60079.1:2015 (IEC 60079-1 Ed.7.0:2015, IDT) Australian/New Zealand Standard Explosive atmospheres Part 1: Equipment protection by flameproof enclosures d Superseding AS/NZS 60079.1:2007 AS/NZS 60079.1:2015

More information

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

AS/NZS :2003 Luminaires - Part 1: General requirements and tests Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60598.1:2003 Luminaires - Part 1: General requirements and tests Table of Contents View on Information Provider

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Page 1 of 4 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate

More information

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 157 Report No.: E309264-D1009-1-CB CB - IEC REPORT: Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:

More information

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear IEC/PAS 62271-109 Edition 1.0 2002-07 High-voltage switchgear and controlgear Part 109: Alternating-current series capacitor by-pass switches PUBLICLY AVAILABLE SPECIFICATION INTERNATIONAL ELECTROTECHNICAL

More information

User s Manual YTA610 and YTA710 NEPSI Certification

User s Manual YTA610 and YTA710 NEPSI Certification User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains

More information

manual addendum DELPHI Ex

manual addendum DELPHI Ex manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 08.0012X issue No.:5

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining The Laboratory is qualified to update standards identifying the test procedures. The laboratory requires/applies a flexible scope of accreditation permitted as detailed in the Annex. Updated list of activities

More information

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX SCHMIDT Flow Sensor SS 20.600 Ex - Supplementary instructions for use in explosive atmospheres ATEX SCHMIDT Flow Sensor SS 20.600 Ex ATEX version Table of Contents 1 Important information... 3 2 Storage

More information

OPTIWAVE X500 Supplementary Instructions

OPTIWAVE X500 Supplementary Instructions OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

National Standard of the People's Republic of China

National Standard of the People's Republic of China National Standard of the People's Republic of China GB 3836.1-2000 eqv IEC 60079-0:1998 Superseding GB 3836.1 1983 Electrical apparatus for explosive gas atmospheres Part 1:General requirements 1 Contents

More information

Amendment to Test Report

Amendment to Test Report - Page 1 of 5 - Test Report issued under the responsibility of: Amendment to Test Report www.nemko.com This Amendment is valid only together with the main Test Report Report o....: 221968 Main Report o...:

More information

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017

More information

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION INTERNATIONAL ELECTROTECHNICAL COMMISSION GUIDE 111 Second edition 2004-07 Electrical high-voltage equipment in high-voltage substations Common recommendations for product standards IEC 2004 Copyright

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60364-5-51 Fifth edition 2005-04 Electrical installations of buildings Part 5-51: Selection and erection of electrical equipment Common rules This English-language version is

More information

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC CLASS PROGRAMME Type approval DNVGL-CP-0396 Edition December 2015 Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC The electronic pdf version of this document,

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:1 Status:

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60694 Edition 2.2 2002-01 Edition 2:1996 consolidated with amendments 1:2000 and 2:2001 Common specifications for high-voltage switchgear and controlgear standards IEC 2002 Copyright

More information

AS/NZS IEC :2013

AS/NZS IEC :2013 AS/NZS IEC 61347.2.13:2013 (IEC 61347-2-13, Ed.1.0 2006, MOD) Australian/New Zealand Standard Lamp controlgear Part 2.13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62040-1-2 First edition 2002-08 Uninterruptible power systems (UPS) Part 1-2: General and safety requirements for UPS used in restricted access locations Alimentations sans interruption

More information

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 165 Report No.: E309264-D1028-1/A0/C0-UL Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARD INFORMATION Standard Number: UL 412 Standard Name: Refrigeration Unit Coolers Standard Edition and Issue Date: 5 th Edition Dated August 22,

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc User manual Explosion-safe window air conditioning system Type series AR-054 II 3 G Ex ic nac h IIC T3 Gc 1. Safety Instructions The window air conditioning series AR-054 is an explosion-safe product suitable

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:0 Certificate history: Status: Current

More information

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,

More information

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements Test Report issued under the responsibility of: TEST REORT IEC 60825-1, 2 nd Edition art 1: Equipment classification and requirements Report Reference No....: EFSH15041135-IE-01-L01 Date of issue...: May

More information

DNVGL-CP-0398 Edition December 2015

DNVGL-CP-0398 Edition December 2015 CLASS PROGRAMME Type approval DNVGL-CP-0398 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH Page /3 SPECIFICATION SHEET Ed. Document UTE_ Issued Written Verified Approved MP36350 6-05-05 Strizzi Franco Page /3 INDICE HISTORY... 3 MODIFY RECORDING... 3 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61892-6 First edition 1999-02 Mobile and fixed offshore units Electrical installations Part 6: Installation Unités mobiles et fixes en mer Installations électriques Partie 6:

More information

AS/NZS :2016

AS/NZS :2016 Australian/New Zealand Standard Luminaires Part 2.2: Particular requirements Recessed luminaires Superseding AS/NZS 60598.2.2:2001 AS/NZS 60598.2.2:2016 (IEC 60598-2-2, Ed. 3.0:2011, MOD) Incorporating

More information

INTERNATIONAL STANDARD NORME INTERNATIONALE

INTERNATIONAL STANDARD NORME INTERNATIONALE IEC 62031 INTERNATIONAL STANDARD NORME INTERNATIONALE Edition 1.0 2008-01 2 62031 IEC:2008 CONTENTS FOREWORD...3 INTRODUCTION...5 1 Scope...6 2 Normative references...6 3 Terms and definitions...7 4 General

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60335-2-17 Second edition 2002-10 Household and similar electrical appliances Safety Part 2-17: Particular requirements for blankets, pads and similar flexible heating appliances

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60335-2-24 Sixth edition 2002-10 Household and similar electrical appliances Safety Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62052-21 First edition 2004-05 Electricity metering equipment (a.c.) General requirements, tests and test conditions Part 21: Tariff and load control equipment IEC 2004 Copyright

More information

AS/NZS :2017. Explosive atmospheres AS/NZS :2017. Part 14: Design selection, erection and initial inspection

AS/NZS :2017. Explosive atmospheres AS/NZS :2017. Part 14: Design selection, erection and initial inspection AS/NZS 60079.14:2017 (IEC 60079-14, Ed. 5.0:2013, MOD) Australian/New Zealand Standard Explosive atmospheres Part 14: Design selection, erection and initial inspection Superseding AS/NZS 60079.14:2009

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60335-2-59 Third edition 2002-10 Household and similar electrical appliances Safety Part 2-59: Particular requirements for insect killers Appareils électrodomestiques et analogues

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61241-1-2 Second edition 1999-06 Electrical apparatus for use in the presence of combustible dust Part 1-2: Electrical apparatus protected by enclosures and surface temperature

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60939-2 Second edition 2005-02 Passive filter units for electromagnetic interference suppression Part 2: Sectional specification Passive filter units for which safety tests are

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD IEC 60092-502 Fifth edition 1999-02 Electrical installations in ships Part 502: Tankers Special features Installations électriques à bord des navires Partie 502: Navires-citernes

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60598-1 Edition 6.1 2006-09 Edition 6:2003 consolidated with amendment 1:2006 Luminaires Part 1: General requirements and tests This English-language version is derived from

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx ETL 13.0026X Issue No:

More information

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas AS/NZS 2290.1:2014 Australian/New Zealand Standard Electrical equipment for coal mines Introduction, inspection and maintenance Part 1: For hazardous areas Superseding AS/NZS 2290.1:2005 AS/NZS 2290.1:2014

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60519-1 Third edition 2003-07 Safety in electroheat installations Part 1: General requirements Sécurité dans les installations électrothermiques Partie 1: Exigences générales

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

TECHNICAL REPORT IEC TR General testing procedures for medical electrical equipment. Edition

TECHNICAL REPORT IEC TR General testing procedures for medical electrical equipment. Edition TECHNICAL REPORT IEC TR 62354 Edition 3.0 2014-09 General testing procedures for medical electrical equipment INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XH ICS 11.040 ISBN 978-2-8322-1856-3 Warning!

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60335-2-69 Edition 3.1 2005-01 Edition 3:2002 consolidated with amendment 1:2004 Household and similar electrical appliances Safety Part 2-69: Particular requirements for wet

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60044-7 First edition 1999-12 Instrument transformers Part 7: Electronic voltage transformers This English-language version is derived from the original bilingual publication

More information

PAKISTAN STANDARD LED MODULES FOR GENERAL LIGHTING (SAFETY SPECIFICATIONS) PS: _5211/2017 ICS:

PAKISTAN STANDARD LED MODULES FOR GENERAL LIGHTING (SAFETY SPECIFICATIONS) PS: _5211/2017 ICS: PS: _5211/2017 ICS: 29.140.99 PAKISTAN STANDARD LED MODULES FOR GENERAL LIGHTING (SAFETY SPECIFICATIONS) (All Rights Reserved) PAKISTAN STANDARDS AND QUALITY CONTROL AUTHORITY, STANDARDS DEVELOPMENT CENTRE,

More information

TRASCO ATEX Couplings

TRASCO ATEX Couplings TRASCO ATEX Couplings ATEX ANNEX GRM-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.it ATEX Annex This Annex is an integral

More information

FLASHLIGHT ANSI STANDARDS

FLASHLIGHT ANSI STANDARDS FLASHLIGHT ANSI STANDARDS While Pelican was one of the first manufacturers to use quantifiable test procedures, the need was recognized to develop a common language that customers could use to select the

More information

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER INSTRUCTIONS FOR SAFE OPERATIONS LM000 EXPLOSION PROOF LASER DISTANCE METER www.cord-ex.com CONTENTS READ THIS FIRST Read This First Liability Trademark Information Product Information Special Conditions

More information

IEC/TC IEC/TC44 IEC/TC44. Amd.1DC:201. Ed.3CD:2011. Ed.2.1:2008. Amd.1CDV ED.1: 一連番号 Ed.

IEC/TC IEC/TC44 IEC/TC44. Amd.1DC:201. Ed.3CD:2011. Ed.2.1:2008. Amd.1CDV ED.1: 一連番号 Ed. IEC/TC44 20-3-7 IEC/TC44 IEC/TC44 6 TC44 TC44 TC44 TC44 TC44 WD, CD, CDV TC44 一連番号 IEC 60027-:992 (Ed.) (995 corrected and reprinted) Letter symbols to be used in electrical technology Part : General 2

More information

SOLUZIONI PER ATMOSFERA ESPLOSIVA

SOLUZIONI PER ATMOSFERA ESPLOSIVA catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60364-5-54 Second edition 2002-06 BASIC SAFETY PUBLICATION Electrical installations of buildings Part 5-54: Selection and erection of electrical equipment Earthing arrangements,

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009 EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009 Number ExNB/CS/ DS (1) Edition Subject / Keywords 98/06/001 1.0 Certification of a torch according to EN

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61810-1 Second edition 2003-08 Electromechanical elementary relays Part 1: General and safety requirements Relais électromécaniques élémentaires Partie 1: Exigences générales

More information

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES ATEX catalogue book 20172018 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first used in the industry. The Company is specialized

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Electrical Safety Requirements

Electrical Safety Requirements Electrical Safety Requirements Purpose This document defines the minimum required control measures to reduce the risk of injury or illness related to electricity. Scope Applicable to all Coca-Cola system

More information