1 THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

2 APP

3 MAIN APP FUNCTIONS EMERGENCY Facilitates the work of installers and company maintenance operators. Allows control of the functions of all lights of the system. Allows adjustment of the duration of emergency lighting according to requirements: 1, 1.5, 2, 3 & 8 hours. Allows light to be set (originally SA) as SE, SA or PS. Monitors periodic test frequencies. Monitors battery status. Sends data to the Beghelli CLOUD to automatically update the lighting system periodic log. Allows direct transmission of test and rest mode commands. LIGHTING Facilitates the work of company maintenance operators. Allows adjustment of the light brightness (maximum and minimum). Allows deactivation, activation and management of the Auto-dimmer function. Allows adjustment of the light power. Allows activation and deactivation of the motion sensor and delay. Allows activation of a light lock code.

4 BEGHELLI CLOUD PORTAL

5 MAIN PORTAL FUNCTIONS LIGHTING & EMERGENCY Facilitates the work of installers and company maintenance operators and allows automatic monitoring of the lighting system periodic log for each and every system, as required by APPLICABLE REGULATIONS. All data is automatically collected via the Opticom Technology App.

6 EMERGENCY APP: SYSTEM CREATION & MAINTENANCE SYSTEM CREATION During the installation of the lights, in order to activate the OPTICOM functions, remove the jumper and connect the battery. With power supply to the light, the indicator LED will become a steady orange to indicate that the light is ready to receive OPTICOM commands. OPTICOM MULTICOLOUR LED INDICATIONS: o STEADY RED: Opticom NOT working - Battery disconnected o STEADY ORANGE: Opticom activated - Configuration NOT complete - Lock code NOT entered o FLASHING ORANGE: Opticom communication active (time window approx. 3 minutes) Now, create a new system and enter each light via the app as indicated in these instructions. At the end of the procedure, all the data will be logged in the OPTICOM portal. SYSTEM MAINTENANCE After creation of the system, actions can be performed via the app at any time, such as checking the status of the system, modifying settings and sending commands.

7 EMERGENCY APP: NEW SYSTEM CREATION INSTALLER LOGIN TYPE SELECTION The app first asks which type of system you want to operate: EMERGENCY or LIGHTING ADD PLANT Allows the addition of a new system Insert SYSTEM DESCRIPTION Insert SYSTEM DATA

8 EMERGENCY APP: NEW SYSTEM CREATION SELECTION OF CREATED SYSTEM SELECTION OF ZONE LIST ADD ZONE INSERT ZONE NAME ADD LAMP Allows the addition of a new light to the selected zone

9 EMERGENCY APP: NEW SYSTEM CREATION LIGHT DESCRIPTION ID decided by user and name indicating position Selection of light to operate OPTICAL SYNCHRONIZATION: LIGHT NOT SYNCHRONIZED (LED indicator steady orange) PHASE 1: UNBLOCK LUMINAIRE (flashing light response and LED indicator flashing orange) Acquisition success: unblocked

10 EMERGENCY APP: NEW SYSTEM CREATION Luminaire set up Acquisition success : unblocked and ready for set up END INSTALLATION Installation COMPLETE CONFIRM WITH BACK BUTTON TO LOG DATA TO THE CLOUD DATA LOGGED IN CLOUD At the end of the communication window (3 min), the LED indicator will turn green.

11 EMERGENCY APP: SYSTEM MAINTENANCE INSTALLER LOGIN TYPE SELECTION PLANT SELECTION EDIT PLANT The app first asks which type of system you want to operate: EMERGENCY or LIGHTING Selection of the system from those installed by the installer logged via LOGIN and PASSWORD The name of the system may be modified at any time.

12 EMERGENCY APP: SYSTEM MAINTENANCE ZONE SELECTION Select the zone to operate ZONE SELECTION Selected lamp screen EDIT LAMP NAME The name of the light may be modified at any time.

13 EMERGENCY APP: SYSTEM MAINTENANCE Take a photo of the installed light to simplify identification and to document correct installation. If, due to a fault, the light can no longer communicate with the smartphone via Opticom, the fault can be reported to the cloud. Restores the light to the original configuration. Works as a lamp reset button. After tapping this button, the light will no longer be synchronized. Deletes the light from the cloud. The light may only be deleted after it has been uninstalled.

14 EMERGENCY APP: SYSTEM MAINTENANCE OPTICAL SYNCHRONIZATION Now proceed with optical synchronization, which is divided in two phases: UNBLOCKING and SYNCHRONIZATION PHASE 1: UNBLOCK LUMINAIRE PHASE 2: SYNCHRONIZE STATUS STATUS Once done, via the smartphone, you can view the status of the light, check for any malfunctions or MODIFY OPERATING PARAMETERS

15 EMERGENCY APP: SYSTEM MAINTENANCE OPTICOM unique identifier code Lamp parameters after synchronization Select duration: 1h, 1.5h, 2h, 3h, 8h Every Opticom product has a default of 1h. This parameter can only be modified via the Opticom app. SE/SA/PS selection (only SA models) Alternating management of duration tests: Even = test one week after odd Fast recharge active = recharge time from 40min to 4 hours (depending on model). With fast recharge activated the SA/PS function is restored at the end of the recharge time (in SA models default is not activated) Fast = duration test always 1h Actual = duration test equal to emergency duration

16 EMERGENCY APP: SYSTEM MAINTENANCE LUMINAIRE ACTIONS Specific commands can be sent directly from the app: SA SE REST MODE, inhibits powering on in emergency START A DURATION TEST START A FUNCTIONAL TEST STOP TEST

17 LIGHTING APP: screens and functions To switch user profile from «BASIC» to «VERIFIED» installer, request the upgrade via the app and follow the steps given. Remember that a BASIC user may only create a system with one zone and a limited number of lights. The upgrade to «VERIFIED» user is free.

18 LIGHTING APP: screens and functions The option «PROGRAMMING» is only visible to the «VERIFIED» installer user profile. COMMANDS At this point, if I am an END-USER, I can command the lights as I want: ADJUST BRIGHTNESS, SWITCH ON OR OFF THE AUTO-DIMMER, ACTIVATE THE MOTION SENSOR and SENSOR DELAY. TYPE SELECTION The app first asks which type of system you want to operate: EMERGENCY or LIGHTING

19 LIGHTING APP: screens and functions On this app screen the user can: Choose the unblock security code previously set by the installer: Opticom communication can only operate if the unblock code and the one set on the light are the same. Light dimmer manual adjustment With AUTO-DIMMER or MOTION SENSOR set to ON it is not possible to manually dim the light. Light power on / off Auto-dimmer on / off Motion sensor on / off With the light set to OFF, the AUTO- DIMMER and MOTION SENSOR functions are not enabled. Once the light configuration is set, it needs to be synchronized with the smartphone. Motion sensor delay: A time ranging from 30 sec to 60 min after which, if the sensor is not triggered by someone moving, the light begins to fade until it reaches the minimum intensity set by the installer. Maximum and minimum power can only be set by a VERIFIED installer user. The time required for the light to go from the maximum power to minimum power gradually is 3 minutes.

20 LIGHTING APP: Installer user screens and functions PROGRAMMING SYNCHRONIZATION For command to be sent, OPTICAL SYNCHRONIZATION must be initiated. Enabled only for installers COMMANDS If you are an INSTALLER (verified user), you will find the programming button enabled, which gives access to various specific exclusive functions.

21 LIGHTING APP: screens and functions Choose the unblock security code previously set by the installer: Opticom communication can only operate if the unblock code and the one set on the light are the same. Setting of the maximum and minimum power of the light when the AUTO-DIMMER and MOTION SENSOR functions are activated by the user. Power of the light when it is powered by direct current, for example, when it is powered by an emergency DC unit.

22 LIGHTING APP: screens and functions Brightness set point which the auto-dimmer, if enabled, will use to regulate the brightness: - Auto-calibration: self-learning - Immediate calibration: manual setting of the set point Percentage of set point brightness required for the light to reach minimum power. The lower the percentage set, the less external light required for the light to start to dim. To avoid too much dimming difference between lights installed in the same environment, the percentage should be kept high. To maximize energy savings, the percentage should be kept lower. The set point is the level of light needed to ensure the optimum level of light in the environment (as per design).

23 LIGHTING APP: screens and functions Motion sensor sensitivity: Set a lower value to avoid false triggering or a higher value if the light is installed up high. Setting a new unblock security code (0-30 and DISABLED): It is recommended to change the unblock code of the lights to prevent others from changing the settings. There is also the option to block use of the Opticom functions by selecting DISABLED. Within the first minute after turning on the light, the new code can be modified independently without use of the old code. After the first minute, the previous code must be known. Every time optical synchronization is initiated, the light will respond by flashing, except for synchronization of manual dimming and on and off functions.

24 OPTICOM Technology default settings AUTO-DIMMER: ENABLED AUTO-CALIBRATION: ENABLED AUTO-DIMMER COMPENSATION: 500% MOTION SENSOR: DISABLED SENSIBILITY: medium MOTION SENSOR DELAY: 16 minutes UNBLOCK CODE: 10

25 How to enable the AUTO-DIMMER, OPTICOM & MOTION SENSOR functions on the SD device AUTO-DIMMER: Connect the OPTICOM sensor. Each SD device already has the Opticom sensor installed but it is disconnected from the driver. Connect the sensor to activate the AUTO-DIMMER function in AUTO-CALIBRATION mode with COMPENSATION set to 500%. OPTICOM COMMUNICATION: After connecting the OPTICOM sensor, remove the labelled jumper. To install the Domotic Radio Module 15022, the jumper must be removed in order to connect the module in its place. In this case the OPTICOM communication must be configured via the SD Manager software. To install the DALI Module 15024, the jumper must be removed in order to connect the module in its place. In this case the OPTICOM communication may not be enabled. To install the 1-10V Module 15034, the jumper must be removed in order to connect the module in its place. In this case the OPTICOM communication may not be enabled. MOTION SENSOR: After connecting the OPTICOM sensor, remove the jumper and enable the function via the OPTICOM app. OPTICOM Technology sensor connector Module connector (DOMOTIC RADIO, DALI, 1-10V) Each OPTICOM SD device will have a jumper attached in this position that must be removed in order to enable the OPTICOM functions.

26 Procedure for setting the operating mode via ON switch (This procedure allows simultaneous set-up of all the lights connected on the same electrical network) Start the sequence with the light already on. The procedure can be performed on various light (e.g. on all lights connected to the same switch). Setting with auto-dimmer and auto-calibration enabled: 1. Turn the light rapidly off and back on four times. (OFF à ON à OFF à ON à OFF à ON à OFF à ON and leave ON), max. time OFF = 1s, max. time ON = 1s. 2. The light will flash twice (OFF à ON à OFF à ON) to indicate correct receipt of the command. 3. The auto-calibration process will start and will require several tens of hours in order to individuate the correct reference point for the auto-dimmer. Setting with auto-dimmer enabled and immediate calibration: This function will calibrate the reference point to the light level at that moment. The setting must be performed at night, or, in any case, without sunlight. 1. Turn the light rapidly off and back on six times. (OFF à ON à OFF à ON à OFF à ON à OFF à ON à OFF à ON à OFF à ON and leave ON), max. time OFF = 1s, max. time ON = 1s. 2. The light will flash three times (OFF à ON à OFF à ON à OFF à ON) to indicate correct receipt of the command. 3. The calibration process will start and will last for 2 minutes at the end of which the light level will be saved as the reference point for the auto-dimmer. This value will NOT be updated automatically by the light. Setting to the maximum power set by the user (auto-dimmer disabled) This will disable the auto-dimmer so that the light will operate always at the maximum power set by the user (via Opticom or radio). The factory setting of this power is at the product specification power. 1. Turn the light rapidly off and back on eight times.(off à ON à OFF à ON à OFF à ON à OFF à ON à OFF à ON à OFF à ON à OFF à ON OFF à ON, and leave ON), max time OFF = 1s, max tempo ON = 1s. 2. The light will flash once (OFF à ON) to indicate correct receipt of the command. 3. The light will go to the maximum power set. From this moment, the power will not change from the maximum value set (modifiable via Opticom or radio).

600 Watt Dimmer Install Guide

600 Watt Dimmer Install Guide 600 Watt Dimmer Install Guide ER6CD This guide covers all models of the ER6CD lighting controller. The box contents includes the controller with lock nut and installation guide. Overview The ER6CD controller

More information

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1 Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) DALI/DSI output channels with adjustable negative offset from channel to channel 1 Ambient light

More information

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor ILD Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) 2 DALI/DSI output channels

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

11,1 30. Ordering data

11,1 30. Ordering data ID Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or I ballasts I/DSI output channels with adjustable negative offset

More information

G4S SMARTalarm User Guide

G4S SMARTalarm User Guide G4S SMARTalarm User Guide CONGRATULATIONS WITH YOUR NEW SECURITY SYSTEM! We are glad that you have chosen G4S SMARTalarm. G4S is the largest supplier of security solutions in the world. We have invested

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

D3D Wi-Fi GSM Smart Alarm System -User Manual

D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM

More information

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)

More information

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC echoflex Powered by ETC Complete Room Controller F series ERDRC-FC This guide covers the F series of the Complete Room Controller, model number ERDRC-FCU equipped with a 902 MHz radio. The box contents

More information

Connections, displays and operating elements C D E G H. Installing the control unit

Connections, displays and operating elements C D E G H. Installing the control unit 1 2 3 GB Control unit 0-10 V REG-K/3-gang with manual mode Operating instructions Art. no. MTN646991 ¼ DANGER Risk of fatal injury from electrical current. All work on the device should only be carried

More information

CSP-204 CSP-208 CSP-104 CSP-108

CSP-204 CSP-208 CSP-104 CSP-108 Fire Alarm Control Panel CSP-204 CSP-208 CSP-104 CSP-108 Operation manual Firmware version 1.1 csp-x_o_en 06/15 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. 58 320 94 00 www.satel.eu CONTENTS

More information

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built

More information

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC echoflex Powered by ETC ER1S-FC Slim Line Dimming Controller F series This guide covers the F series of the Complete Room Controller, model number ER1S-FCU equipped with a 902 MHz radio. The box contents

More information

DEFA HOME. User Manual Base Unit PRO

DEFA HOME. User Manual Base Unit PRO DEFA HOME User Manual Base Unit PRO Table of Contents Overview 5 Logging into the app 9 Home 10 Calendar 13 Adding an event 14 Editing an event 15 Zones 16 Switch mode 17 Thermostat mode 19 Regulator

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

Door/Window Sensor. Set-Up Guide

Door/Window Sensor. Set-Up Guide Door/Window Sensor Set-Up Guide Thanks for choosing Rogers Smart Home Monitoring! Once you ve set-up your Door/Window Sensor, you can receive notifications if a window or door in your home opens unexpectedly.

More information

Technical Manual. Level Alarm Unit CARLA & WIDS

Technical Manual. Level Alarm Unit CARLA & WIDS CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks

More information

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional: status ALC-PACK3 WiFi Alarm System with HD WiFi Camera User Manual Your Watchguard Wireless Security professional: www.activeonline.com.au 1300 816 742 Foreword Congratulations on your purchase of the

More information

Alarm System SECURE AS 302

Alarm System SECURE AS 302 Alarm System SECURE AS 302 Operating Manual SECURE Light app now available! Table of Contents Before You Start.................................. 4 User Information....................................4

More information

Independent Zone Control (I.Z.C.)

Independent Zone Control (I.Z.C.) Operation and Installation Guide Independent Zone Control (I.Z.C.) DELAYED INSTANT ARMED 1 2 3 4 7 5 6 8 9 * * fi Radionics R D279A Operation & Installation Guide 46456B Page 2 Copyright 2000 Radionics

More information

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved. status 2016 Chuango. All Rights Reserved. Printed in China PA : AW1-UM-EN-V1.0 AW1 WiFi Alarm System User Manual Foreword Contents Congratulations on your purchase of the AW1 Alarm system. Before you commence

More information

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad... 2 Contents Glossary...7 1. Introduction to the IDS805...8 1.1 Notes...8 2. Understanding the Keypad Indicators...8 3. Operation of the Keypad...9 4. System Information...10 4.1 Programmed Functions...10

More information

status AW1 Plus WiFi Alarm System User Manual

status AW1 Plus WiFi Alarm System User Manual status AW1 Plus WiFi Alarm System User Manual Foreword Congratulations on your purchase of the AW1 Plus Alarm system. Before you commence installation we recommend that you unpack the product, familiarise

More information

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat Thermostat Guide Online Guide Brighten Conservation Program Personal Reference Guide Brighten ithermostat Thermostat Guide Online Guide Brighten Conservation Program Welcome to your new Brighten ithermostat

More information

Wireless Keypads LKP(E)S8M Series

Wireless Keypads LKP(E)S8M Series Wireless Keypads LKP(E)S8M Series User manual Contents Congratulations on your purchase of this Honeywell wireless keypad. To make the best out of your equipment we advise you to read this manual carefully.

More information

luxcontrol DALI basicdim DGC Product Manual

luxcontrol DALI basicdim DGC Product Manual luxcontrol DALI basicdim DGC Product Manual Table of Contents 1. Scope of documentation 3 1.1. Copyright.................................................................................................................

More information

Passive infrared ceiling sensor

Passive infrared ceiling sensor Passive infrared ceiling sensor 88 Description Control and command device, powered by the SCS BUS, with two different sensors, the combination of which enables managing the light level inside the room,

More information

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

IDS800 USER MANUAL. Summary of Operation.   + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay Arm Stay Arm & Go H old down [ 1] for 1 second H old down [ 5] for 1 second H old down [ 6] for 1 second Panic Fire Medical

More information

Use of the application program

Use of the application program Contents overview Use of the application program Use of the application program 1 1. Functional description 2 Switching on / off 2 Dimming brighter / darker 2 Dimming value (8 bit) 3 Status Switching (1

More information

Total Connect Box. User manual

Total Connect Box. User manual Total Connect Box User manual 1 Congratulations on your purchase of the Honeywell Total Connect Box security system. To make the best out of your system we advise you to read this manual carefully. This

More information

The easier, smarter heating system. Multi-zone heating made easy. User guide Setup and control

The easier, smarter heating system. Multi-zone heating made easy. User guide Setup and control The easier, smarter heating system Multi-zone heating made easy User guide Setup and control Getting to know the Wiser system Wiser system Smart heating for your home Wiser is designed to be simple to

More information

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors 1 Set Up After downloading the Weatherhub app, follow these steps: 1.1 Connect the Gateway Connect

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

Wireless Keypad GKP-S8M

Wireless Keypad GKP-S8M Wireless Keypad GKP-S8M User manual Contents Congratulations on your purchase of this Honeywell wireless keypad. To make the best out of your equipment we advise you to read this manual carefully. This

More information

IDS816 User Manual H Issued January 2009

IDS816 User Manual H Issued January 2009 1 Contents Glossary-------------------------------------------------------------------------------------------------------------------6 1. Introduction to the IDS 816---------------------------------------------------------------------------7

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Sensor Cloud User Manual

Sensor Cloud User Manual Sensor Cloud User Manual Table of Contents DEVICES TAB 4 1. DEVICE LIST 4 2. EXPAND ALL 4 3. EXPAND 4 4. STATUS 4 5. DEVICE 4 6. NAME 5 7. MONITORING INTERVAL 5 8. LAST ACTIVITY 5 9. VIEW 5 10. DELETE

More information

Radio fire warning panel SRC 3000

Radio fire warning panel SRC 3000 Radio fire warning panel SRC 3000 6 zone radio fire warning panel Operating instructions Version 1.2 Art. 32487 detectomat GmbH Headquarter: Phone: +49 (0) 4102-2114-60 An der Strusbek 5 Fax: +49 (0) 4102-2114-670

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

Total Protection Alarm System

Total Protection Alarm System Total Protection Alarm System SMARTHOME #7307 PAT. D410633 Patents Pending Your Guide to the Total Protection Alarm System SMARTHOME #7307 2 TABLE OF CONTENTS PACKAGE CONTENTS...4 OVERVIEW...5 PLANNING

More information

Tebis application software

Tebis application software 5 Tebis application software STCC530E 2-channel presence detector 360 A faire Product reference Description TP device RF devices TCC530E Bi-zone presence detector TCC530E Output module: Dimmer Loads connected

More information

SIMPLIFIED HOME SECURITY AND CONTROL

SIMPLIFIED HOME SECURITY AND CONTROL SIMPLIFIED HOME SECURITY AND CONTROL HOME CONTROLLER USER GUIDE HOME CONTROLLER Mediacom introduces a whole new level of security for the things that matter most in your life. Whether you re home or away,

More information

Advisor Advanced Mobile Application User Manual

Advisor Advanced Mobile Application User Manual Advisor Advanced Mobile Application User Manual Content Warnings and Disclaimers 2 Advanced Mobile 2 Contact information 2 Description 2 Screen navigation 4 Gestures 4 Menu 4 Help navigation 4 Login 5

More information

Sales FAQ. Paradox Insight - General. 1. What is Paradox Insight?

Sales FAQ. Paradox Insight - General. 1. What is Paradox Insight? Sales FAQ We ve compiled a list of frequently asked questions regarding Paradox Insight solution to assist you in the marketing and sales of your Paradox Insight solution. If you have a question that does

More information

SA 2650 Kit User Manual

SA 2650 Kit User Manual SA 2650 Kit User Manual Table of Contents 1. System Installation Planning 1 2. Device Introduction 3 3. Getting Started 6 4. System Default Setting 10 5. Connect2Home Application 11 6. System Information

More information

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E ) 1 Installation Guide NookBox Keypad (P119010 / E6309744) 2 NookBox Keypad (P119010 / E6309744) 3 Parts Identification 1. Active LED 2. Status LED 3. Fault Display LED 4. Arm Key 5. Home Key 6. Key Check

More information

1126 Series Ceiling Mount PIR Motion Detector

1126 Series Ceiling Mount PIR Motion Detector Installation Sheet 1126 Series Ceiling Mount PIR Motion Detector Description The 1126 Series PIR (Passive Infrared) Motion Detectors are a compact wireless PIR. The 1126 Series offer 360, Wide Angle, or

More information

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming

More information

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD.

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD. 1 2 3 4 5 6 7 8 IN OFF ON + T S B J Т1 ocbridge Plus 1. FEATURES Wireless sensors receiver ocbridge is designated for connecting compatible Ajax devices to any third party wired central unit (panel) with

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

Door/Window Sensor. Set-Up Guide

Door/Window Sensor. Set-Up Guide Door/Window Sensor Set-Up Guide Thanks for choosing Rogers Smart Home Monitoring! Once you ve set-up your Door/Window Sensor, you can receive notifications if a window or door in your home opens unexpectedly.

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

PERMACONN PM1030 Includes DI300. Installation Manual

PERMACONN PM1030 Includes DI300. Installation Manual PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides

More information

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright CG500SKE SKYEYE GATEWAY USER MANUAL CG500SKE SkyEYE Gateway VERSION 1.2 26 OCTOBER 2014 Disclaimers and Copyright Nothing contained in this publication is to be construed as granting any right, by implication

More information

Description of the application programme for KNX occupancy detectors version 3.1

Description of the application programme for KNX occupancy detectors version 3.1 Contents 1. General...1 1.1 Basics for the KNX/EIB BUS...1 1.2 Application versions...1 1.2 Application versions Switchgear application Version 3.1: BEG_SWI_HKL_V3.1 Part numbers: 1.3 Symbols used...1

More information

Devices for Special Applications

Devices for Special Applications Overview AP 2/11 UP 2/12 N 26/02 UP 28/11 UP 28/21 N 342 AP24/02 GE 22 GE 23 GE 24 UP 2 AP 2 Control Integrated constant light level control 1-channel 3-channel -- -- -- 1-channel -- -- 1-channel -- 1-channel

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

MyNice Welcome to your Nice World. The intelligent solution for the integrated management of the alarm system and of the home s automations.

MyNice Welcome to your Nice World. The intelligent solution for the integrated management of the alarm system and of the home s automations. MyNice Welcome to your Nice World The intelligent solution for the integrated management of the alarm system and of the home s automations. Home page Wi-Fi and GSM status and connected users System name

More information

IP65 High Bay Dual Sense Sensor

IP65 High Bay Dual Sense Sensor IP65 High Bay Dual Sense Sensor TM and, Daylight Harvest with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

GSM RFID VOICE Alarm System

GSM RFID VOICE Alarm System GSM RFID VOICE Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS [Function Instruction] [Control Panel] Control Panel

More information

abode Web app Functionality

abode Web app Functionality abode Web app Functionality System mode display controls the state of the alarm system. The user can change the mode of the system by simply clicking on the desired mode. When arming the system with the

More information

Smart Starter Bundle. Hub. Smart Motion Sensor. Smart Door/ Window Sensor

Smart Starter Bundle. Hub. Smart Motion Sensor. Smart Door/ Window Sensor User Guide 01 Smart IP Camera Smart Zigbee Hub Smart Motion Sensor Smart Door/ Window Sensor Smart Starter Bundle Thanks for using Aztech Kyla product If you need support or help, please visit www.kyla.aztech.com

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Quick start. 2. Turn on the power. When all the led indicator light turns off, the device status is normal, has entered the work state.

Quick start. 2. Turn on the power. When all the led indicator light turns off, the device status is normal, has entered the work state. Multi 3G MODULE Content Quick start...2 Features...3 Specifications...3 Keys and Parts...4 SMS Commands...5 Example...7 Setting the alert number...7 Delete the alert number...8 Email and GPRS APN setting...8

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

HMS MODEL 800 Owner s Manual

HMS MODEL 800 Owner s Manual HMS MODEL 800 Owner s Manual OnQ Document Number 1307535 Rev A October, 2000 Copyright v 2000 HAI All Rights Reserved www.onqtech.com Contents INTRODUCTION... 1 Underwriter's Laboratories (UL) Listing...

More information

SmartONE Kit. User Manual

SmartONE Kit. User Manual SmartONE Kit User Manual Thank you for choosing BroadLink DNA series products Packing List Please confirm the items are in good conditions as below SOS SmartONE x1 Wireless Key Fob Remote x1 Wireless Door

More information

TSM/TSSM OVERVIEW 3.1

TSM/TSSM OVERVIEW 3.1 TSM/ OVERVIEW 3.1 GENERAL 7844 See Figure 3-1. The turn signal module (TSM) has two major functions: Control turn signals. Serve as bank angle sensor. The optional, factory-installed, security system (turn

More information

IRIS Touch Firmware Enhancements and Additions from Version to Version

IRIS Touch Firmware Enhancements and Additions from Version to Version Overview IRIS Touch Firmware Enhancements and Additions from Version 1.14.3 to Version 1.19.1 This document details enhancements to the feature set of the IRIS Touch from firmware Version 1.14.3 to Version

More information

* _rev1* User guide DRIVER 230 CPL. 3 zone weekly programmer using power line carriers

* _rev1* User guide DRIVER 230 CPL. 3 zone weekly programmer using power line carriers User guide DRIVER 230 CPL 3 zone weekly programmer using power line carriers DELTA DORE - Bonnemain 35270 COMBOURG - FRANCE E-mail : deltadore@deltadore.com Device complying with the requirements of the

More information

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR GB Contents 1. GENERAL 1 1.1 KNX bus basics 1 1.2. Overview 1 1.3 Symbols 1 2. OCCUPANCY DETECTOR BASICS 2-3 2.1 Introduction 2 2.2 Motion detection with the B.E.G.

More information

RE6100 Series Helix Security and Automation Platform

RE6100 Series Helix Security and Automation Platform CONFIGURATION Resolution Compatibles RE6100 Series Helix Security and Automation Platform C G UI D E Configuration Settings Table 1 - Panel Settings Table 2 - Zone Settings Table 3 - Device Settings Table

More information

ProStar 325 UV-Vis Detector

ProStar 325 UV-Vis Detector Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Star Chromatography Workstation Version 6 ProStar 325 UV-Vis Detector Control Software Varian, Inc. 2004 Printed in U.S.A. 03-914732-01:Rev.

More information

User s Information Guide R2A

User s Information Guide R2A Pi HSC505 Home Security Controller User s Information Guide R2A Page 1 of 15 of its development program. 1This document and product are copyrighted and all rights are reserved. Introduction Convention

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

l 02-April-2010 For INSTANT CARE

l 02-April-2010 For INSTANT CARE l 02-April-2010 For INSTANT CARE Table of Contents 1. Application Overview 1 1.1. Identifying The Parts 1 1.2. The Power Supply 3 1.3. Line Capture 3 1.4. Line Failure Detection 4 1.5. How to install the

More information

Architectural and Engineering Specification for a Real-Time Locating System Flare

Architectural and Engineering Specification for a Real-Time Locating System Flare Architectural and Engineering Specification for a Flare AE-T1-IN-R3-E-0617 Page 1 of 14 This document is intended to provide performance specifications and operational requirements for the Flare. It is

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

Glass Break Sensor. Set-Up Guide

Glass Break Sensor. Set-Up Guide Glass Break Sensor Set-Up Guide Thanks for choosing Rogers Smart Home Monitoring! Once you've set-up your Glass Break Sensor, you can receive notifications if the sound of breaking glass is detected in

More information

IP65 High Bay Dual Sense Sensor

IP65 High Bay Dual Sense Sensor IP65 High Bay Dual Sense Sensor TM and, 1-10V Dimming with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High Frequency

More information

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. SYSTEM USER GUIDE SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM If

More information

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

INSTRUCTION MANUAL Z-WAVE DIMMER 12387 INSTRUCTION MANUAL Z-WAVE DIMMER 12387 Z-Wave DIMMER BASICS The Kichler Z-Wave full range dimmer is designed to allow your Kichler Design Pro LED fixtures to communicate with one another as well as to

More information

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS... SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................

More information

xcomfort Room Controller Touch User Manual xcomfort Room Controller Touch User Manual 0v17_EN

xcomfort Room Controller Touch User Manual xcomfort Room Controller Touch User Manual 0v17_EN xcomfort Room Controller Touch User Manual For other languages and information about xcomfort, visit www.eaton.eu/xcomfort or www.xcomfort.com or use the QR-code. Für weitere Sprachen und Informationen

More information

2G & 3G GSM Wireless Beam Alarm

2G & 3G GSM Wireless Beam Alarm 2G & 3G GSM Wireless Beam Alarm www.gsm-activate.co.uk MODEL RF - BEAM PAGE 1 Product Information Our 2G/3G GSM Wireless Beam Alarm is a standalone alarm system suitable for indoor and outside use. It

More information

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR In the Master function, the remote control entries will be acknowledged as follows: acknowledged 3 x with the red LED In the Slave function, each detection is acknowledged 2 x with the green LED. NOTE:

More information

Supervised Security System Owner's Guide

Supervised Security System Owner's Guide Owner's Guide PSC06 READ THIS FIRST This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions,

More information

Protect and connect. Home and away.

Protect and connect. Home and away. Protect and connect. Home and away. USER GUIDE For Additional Support: http://www.cox.com/homesecuritysupport For Additional Support: http://www.cox.com/homesecuritysupport 2 CONTENTS Contents Components

More information

The Dorm Room Genie. The Door Lock --To be completed by David Nedzel

The Dorm Room Genie. The Door Lock --To be completed by David Nedzel The Door Lock The Dorm Room Genie Students are issued keys by which to access their rooms, but far too often a key is forgotten inside the room leaving someone locked out. After a lockout, a student must

More information

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information