Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Size: px
Start display at page:

Download "Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive"

Transcription

1 Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber UV-resistant, metal-free, longitudinally waterproof, tensile strength and rodent repellent cable jacket: LSHF cable structure: filled loose tubes cable diameter for central loose tube 7.5 with 2 to 12 fibers per loose tube cable diameter for central loose tube 8.0 with 24 fibers per loose tube cable diameter with stranded loose tube 11.0 strain relief: longitudinally waterproof wrapping, glass roving elements stranded loose tubes: loose tubes grouped around a glass fiber reinforced plastic stick with a dia. of 2.5 for laying in ducts or directly in the ground in a suitable layer of sand applicable standards: EN , ISO nd edition, IEC , EN fire behaviour: Class E ca Variant: Number of OM4 fibers Number of OM3 fibers Number of OM2 fibers 1x4, 1x8, 1x12, 1x24, 4x12 1x4, 1x8, 1x12, 1x24, 4x12 1x4, 1x8, 1x12 *The indication of fire protection classification is currently for

2 Illustrations Page 2/7 your General information Dataonly and becomes binding only after the assignment of the DoP number. Fields of application Design Transmission technology Color Color coding fiber/ wire(s) Mode type of the fiber Structured building cabling, Office Data center Installation cables Fiber optic blue see table Multimode Fiber class OM4 (ISO/IEC 11801/EN & IEC /EN A1.a.3) Number of cables/ cores 1 Number of fibres each cable/ wire 24 Fiber construction 50/125 µm Weight kg/km Connections/interfaces Connector technology interface 1 Connector technology interface 2 Cable sheath diameter (min. - max.) Cable sheath diameter Cable sheath diameter in. Mechanical characteristics Strain relief Permanent tensile strength Short term tensile strength Maximum installation load (max.) Maximum installation load Maximum installation load Maximum operating bending radius Maximum operating bending radius Crush (compressive strength) Torsion resistance Fire load longitudinally waterproof wrapping, glass roving elements 700 N 1000 N 1500 N in in N 5 cycles ± 1 revolution 1300 MJ/km

3 Page 3/7 Materials and material properties Material - Cable jacket Bend insensitivity Tensile strength Rodent protection Flame retardancy Halogen free Metallfrei UV-resistance Longitudinal water tightness LSHF pass, no water on free end Environmental conditions Temperature (min. - max.) Temperature - Storage C C Temperature - Storage F F Temperature - Operating C C Temperature - Operating F F Temperature - Installation C C Temperature - Installation F F Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements ISO/IEC Ed.2 DIN EN : 2002 Optical fibers: Generic specification General ISO/IEC Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content IEC Determination of acidity (by measuring the ph value) IEC and conductivity Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated ISO/IEC wire or cable Measurement of smoke density of cables burning ISO/IEC

4 Page 4/7 The product meets the following standards Coon test methods for cables under fire conditions Fire behaviour - class Class E ca * Classifications ETIM 5.0 ETIM 6.0 EC EC Packing details Type of packaging meter / drum

5 Fiber color coding Page 5/7 Fiber color code 1 red 13 yellow w/mark per 70 2 green 14 white w/mark per 70 3 blue 15 grey w/mark per 70 4 yellow 16 turquoise w/mark per 70 5 white 17 orange w/mark per 70 6 grey 18 pink w/mark per 70 7 brown 19 yellow w/mark every 35 8 violet 20 white w/mark every 35 9 turquoise 21 grey w/mark every black 22 turquoise w/mark every orange 23 orange with w/mark every pink 24 pink w/mark every 35

6 OpDAT fiber OM4 BR Page 6/7 150XXX7 General Data Transmission technology Mode type of the fiber Fiber optic Multimode Fiber class OM4 (ISO/IEC 11801/EN & IEC /EN A1.a.3) Fiber construction 50/125 µm Transmission characteristics Transmission rate up to 100 GBit Overfilled (OFL) modal bandwidth at 850 nm (min.) Overfilled (OFL) modal bandwidth at 1300 nm (min.) Effective modal bandwidth (EMB) at 850 nm (min.) IEEE 802.3ba 3500 MHz * km 500 MHz * km 4700 MHz * km Connections/interfaces Connector technology interface 1 Connector technology interface 2 Fasermanteldurchmesser ± 1.0 µm Primary coating diameter - colored 242 ± 5 µm Primary coating diameter - uncolored 250 ± 15 µm Mechanical characteristics Proof stress level Strip force (peak) min. 0.7 ( 1 %) GPa Fiber cladding non-circularity max. 0.7 % Core non-circularity max. 5 % Core (MDF)-cladding concentricity error max. 1 µm Primary coating concentricity error max. 5 % Primary coating-cladding concentricity error max <= Fpeak.strip <= 8.9 N Inhomogeneity of OTDR measurement report at 1310 max. 0.1 db/km nm und 1550 nm Numerical aperture ± Materials and material properties Bend insensitivity

7 Powered by TCPDF ( OpDAT fiber OM4 BR Page 7/7 150XXX7 The product meets the following standards Generic cabling systems General requirements ISO/IEC DIN EN TIA/EIA 568-C Data centers ISO/IEC Optical fibers: Measuring methods and test procedures Fibre geometry ISO/IEC Coating geometry ISO/IEC Length measurement ISO/IEC Fibre proof test ISO/IEC Coating strippability ISO/IEC Attenuation ISO/IEC Bandbreite ISO/IEC Numerical aperture ISO/IEC Gruppenlaufzeitdifferenz ISO/IEC Optical fibers: Product specifications Sectional specification for category A1 multimode fibres ITU-T standard TIA/ANSI-492 ISO/IEC (A1a.3) G AAAD

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST

More information

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

HELKAMA. Optical Fibre Cables

HELKAMA. Optical Fibre Cables 1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre

More information

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4

More information

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13. GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description

More information

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information. GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET Optic Backbone Distribution Cables 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: TE

More information

Fiber Optic Distribution Cables (6-144 Fibers)

Fiber Optic Distribution Cables (6-144 Fibers) 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are

More information

Duct Cable GYTS-144B1.3

Duct Cable GYTS-144B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical

More information

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R GOF Indoor and Outdoor Cables Documentation VWL 064.504 Version 2.2 Source Code R GOF Installation Cables Cable matrix / overview Source code: R Use Indoor In- / Outdoor Outdoor Type of cable Breakout

More information

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M GOF Indoor and Outdoor Cables Documentation VWL 064.503 Version 1.1 Source Code M GOF Installation Cables Cable matrix / overview Source code M Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini-

More information

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3 VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Ø 1000 * 588 mm 50 kg

Ø 1000 * 588 mm 50 kg GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx fibrewave About Us Prysmian is a global market leader in optical cables, supplying a major part of the world s optical cable needs. With a strong heritage of highly advanced R&D, Prysmian is at the leading

More information

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1

More information

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003 Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone

More information

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits GBRD Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 24 36 48 60 72 62.5/125-OM1 GBRD124 GBRD136 GBRD148 GBRD160

More information

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSA Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 62.5/125-OM1

More information

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm). GCDG Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

industry solutions: military

industry solutions: military industry solutions: military MC industry Solutions: Military A tradition of leadership in technology, product performance for military applications Optical Cable Corporation is a leading manufacturer of

More information

SPECIAL ELECTRICAL AND OPTICAL CABLES

SPECIAL ELECTRICAL AND OPTICAL CABLES SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.

More information

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD INTERIM EUROPEAN I-ETS 300 644 TELECOMMUNICATION June 1997 STANDARD Source: ETSI TC-TM Reference: DI/TM-01021 ICS: 33.020 Key words: Fibre, cable, optical, transmission Transmission and Multiplexing (TM);

More information

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T Translated English of Chinese Standard: YD/T1447-2013 www.chinesestandard.net Sales@ChineseStandard.net COMMUNICATION INDUSTRY STANDARD OF THE PEOPLE S REPUBLIC OF CHINA YD ICS 33.180.10 M 33 Replacing

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

Fibre Specification Standards

Fibre Specification Standards Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair

More information

Fiber Optic Patch Cord and Pigtails

Fiber Optic Patch Cord and Pigtails Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable

More information

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION 13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION This specification is property of SEC and subject to change or modification

More information

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 90 TKF developed from a cable producer to a leading

More information

STANDARD CONFORMANCE

STANDARD CONFORMANCE STANDARD CONFORMANCE IEC 60331-11, Tests for electric cables under fire conditions- Circuit integrity- Fire alone at a flame temperature of at least 750C IEC 60331-21, Tests for electric cables under fire

More information

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT) TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions

More information

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing

More information

Fibre Optic Cable. Catalogue.

Fibre Optic Cable. Catalogue. Fibre Optic Cable Catalogue www.fibrefab.com About The FibreFab Group FibreFab Established in 1992, FibreFab is a leading provider of fibre optic connectivity products used in data communications and Telecommunication

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0401 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Product Specification CAT 6 UNSHIELDED PATCH CORDS Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE ANSI/ICEA S-104-696-2001 STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE Publication S-104-696 First Edition - September 2001 Published By Insulated Cable Engineers Association, Inc. Post Office Box 1568

More information

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

CATEGORY 6A FTP RJ45 SOLUTION

CATEGORY 6A FTP RJ45 SOLUTION CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium

More information

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre. Specification No.CSC-131/R-1/DH//UH/P&D/2016-17 Technical Specifications for 24 Fiber/48 Fiber Unarmoured Underground Fibre Optic Cabling Issue Month:June-2016 (CSC Amendment date 14.06.2016) Common Specification

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes the following: 1. 50/125-micrometer, optical fiber cabling. 2. Cable connecting hardware, termination panels,

More information

MT-RJ Optical Fiber System Field Testing

MT-RJ Optical Fiber System Field Testing MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)

More information

Fibre optic media options and trends

Fibre optic media options and trends Fibre optic media options and trends Presented by D Stockton & P Lascelles of Miniflex Ltd, branded as m2fx 23 February 2012 1 Contents Cable constructs Indoor/outdoor LSZH Armouring Micro Bends Singlemode,

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

ENHANCED FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAE00000GG Revision No: 2 This is to certify: That the Data transmission cables and systems with type designation(s) MGD Cat 3, MGD Cat 5, Cat 5e, MGD cat 6, Cat

More information

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. Special Provision No. 683S01 December 2017 1. SCOPE This Special Provision covers

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE Publication # ICEA S-104-696 Second Edition March 2013 2013 by ICEA INSULATED CABLE ENGINEERS ASSOCIATION, Inc. STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER

More information

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

Cat 6 Shielded Patch cords

Cat 6 Shielded Patch cords Product Specification 108-93010 14/Oct/2009 Rev E Cat 6 Shielded Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT*

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

Fire Safety Fire Resistant Building Components

Fire Safety Fire Resistant Building Components Fire Safety Fire Resistant Building Components NBN 713-020 1968 Fire fighting - Fire performance of building materials and products - Fire resistance of building materials NBN 713-020/A1 1982 Protection

More information

Qualification Test Report LC Duplex Adapter For LC Cutouts

Qualification Test Report LC Duplex Adapter For LC Cutouts Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their

More information

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED FUMEGUARD TM LOW SMOKE HALOGEN FREE CABLES The longest-running original range of low voltage, low smoke, halogen free

More information

Sensing Technology. A company of the BRUGG Group

Sensing Technology. A company of the BRUGG Group Sensing Technology. Applications. 2 Basic_Sensing_e.ppt / ad Laser. LASER λ 0 [nm] Intensity λ [nm] λ 0 3 Basic_Sensing_e.ppt / ad Rayleigh, Brillouin, Raman Scattering. LASER λ 0 [nm] Rayleigh Intensity

More information

Dome Fiber Optic Closure SC-221

Dome Fiber Optic Closure SC-221 Dome Fiber Optic Closure SC-221 General Information SC-221 fiber optic closure protects the fiber optic splices from harsh external environment conditions. It is designed for many network segments and

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team INTRODUCTION The OTDR is a very efficient tool for characterizing the elements on

More information

ITU-T L.404. Field mountable single-mode optical fibre connectors

ITU-T L.404. Field mountable single-mode optical fibre connectors I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.404 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/2017) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY

More information

Üntel is ready for CPR

Üntel is ready for CPR 2016 Üntel is ready for CPR Hakan Kubas Marketing Manager 01.11.2016 Construction Products Regulation What is the CPR? The Construction Products Regulation (CPR) lays down conditions for the placing or

More information

FIRE PERFORMANCE CABLE

FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor

More information

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable

More information

Cat 6 Unshielded Patch cords

Cat 6 Unshielded Patch cords Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded s 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat

More information

OFS IV Optical Fibre System

OFS IV Optical Fibre System OFS IV Optical Fibre System FOR ALL FIBRE OPTIC USERS Fibre optic training has assumed great importance in today s world of widespread fibre optic usage whether in telecommunications or railways, industrial

More information

Jan07 Rev B

Jan07 Rev B Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-6 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 6: Symmetrical pair/quad cables with transmission characteristics up

More information

OPTICAL FIBER SOLUTIONS

OPTICAL FIBER SOLUTIONS www.ofsoptics.com/medical OPTICAL FIBER SOLUTIONS FOR YOUR MEDICAL DEVICE ISO 9001 and 13485 Certified FDA Good Manufacturing Practices USP Class VI and ISO10993 for Biocompatibility Low Bioburden Assembly

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Basic Professional Fiber Optic Installation

Basic Professional Fiber Optic Installation Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:

More information

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical

More information

/Oct/2014 Rev E

/Oct/2014 Rev E Product Specification 108-93017 14/Oct/2014 Rev E Cat 6 Unshielded Patch Cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE Connectivity

More information

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing Hands-On Splicing, Termination & Testing BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.36 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

More information

FIRST-CLASS IN TRAINS

FIRST-CLASS IN TRAINS FIRST-CLASS IN TRAINS Powered by TCPDF (www.tcpdf.org) Powered by TCPDF (www.tcpdf.org) Advanced fire protection for railway vehicles: hazard level 2 & 3 according to EN 45545 Effectively prevents moisture

More information

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE Carol Harris, EMEA Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Combustible construction materials

More information

Single core cables with reduced wall thickness

Single core cables with reduced wall thickness Product description: RADOX 4 GKW -AX 1800V M Nominal voltage: Hazard level: Single core cables with reduced wall thickness 1800 / 3000 V AC M (extra low temperature, extra oil and extra fuel resistant)

More information