INSTALLATION MANUAL PC56O. Version 1.OA

Size: px
Start display at page:

Download "INSTALLATION MANUAL PC56O. Version 1.OA"

Transcription

1 INSTALLATION MANUAL PC56O Version 1.OA

2 TABLE OF CONTENTS INTRODUCTION 3 Features... 3 Specifications... 3 INSTALLATION 4 Mounting the Control Panel... 4 Mounting the Keypad... 4 Wiring... 5 Burglary Zone Wiring... 5 Auxiliary Power Connection... 5 PGM OUT Terminal Connection... 5 STR Terminal Connection... 6 KEY Terminal Connection... 6 Battery Connection... 6 AC Power Wiring... 6 Telephone Line Wiring... 6 KEYPAD FUNCTIONS 7 Introduction... 7 Master Code... 7 Installer s Programming Code... 7 Arming... 7 Auto-Bypass/Home-Away Arming... 7 At-Home Arming... 7 Disarming... 8 Important Note about Keypad [ ] Commands... 8 [ ]+[0]: Quick-Arm... 8 [ ]+[1]+[Access Code]: Zone Bypassing... 8 [ ]+[2]: Display Trouble Conditions... 8 [ ]+[3]: Display Alarm Memory... 9 [ ]+[4]: Bell Test... 9 [ ]+[5]+[Master Code]: Program Access Codes... 9 [ ]+[6]: Door Chime On/Off... 9 [ ]+[8]+[Installer s Code]: Installer s Programming Command... 9 [ ]+[9]: At-Home Arming Keypad Zones Adjusting the Keypad Sounder Tone and Backlighting

3 PROGRAMMING GUIDE 11 Sections [05] through [07]: Selecting System Functions HEX Data Programming Resetting Programming to the Factory Default Settings PROGRAMMING SECTIONS 12 [01] Zone Definitions [02] System Times [03] Installer s Code [04] Programmable Output Options (PGM OUT Terminal) [05] 1st System Option Code [06] 2nd System Option Code [07] 3rd System Option Code [08] First Phone Number [09] Second Phone Number [10] Customer Account Code Disabling Communications [11] Zone Alarm and Restoral Reporting Codes [12] Closing and Opening Reporting Codes [13] Maintenance and Priority Codes [14] Downloading Access Code FOR THE RECORD 18 PROGRAMMING WORKSHEETS HOOK-UP DIAGRAM 23 LIMITED WARRANTY 24 2

4 INTRODUCTION FEATURES Fully featured security system with Trouble Supervision, Alarm Memory, Master Code and 3 programmable Access Codes, Quick-Arming and At-Home Arming, Door Chime, 3 one-touch Keypad Zones, and more Digital Communicator with 40 BPS Non-Extended 4/2 with Parity format or Private Line format 4 End-of-Line Resistor Supervised Zones 6 Programmable Zone Types with Silent or Audible alarms Programmable Output with 2 options Dedicated Strobe (latched alarm) Output KEY Terminal can be used for Momentary or Maintained Keyswitch Arming, or as a 24-hour Endof-Line Resistor Supervised Tamper Zone To help prevent false alarms, all zones are automatically bypassed for 120 seconds on powerup to allow detectors to settle All Installer s Programming can be done at the keypad or through downloading EEPROM memory retains all programming even after all power is removed from the control panel Advanced static and lightning protection; unique Zap-Trac circuit board design stops damaging voltages at the wiring terminals, and transient protection devices are placed in all critical areas for further protection SPECIFICATIONS PC560 Control Panel Four fully programmable zones Zones are End-of-Line Resistor supervised Maximum zone loop resistance: 100 ohms Bell/Siren Output: fused for 5A Bell / Siren Alarms: steady and pulsed alarms Programmable Output: 300 ma with 2 options Auxiliary Power Output: 800 ma with 40 VA transformer 500 ma with 20 VA transformer Maximum 3 Keypads per system, and Keyswitch Required Battery: 12 VDC 1.2 Ah provides 4 hours of stand-by at 200 ma Auxiliary Output 4.0 Ah provides 4 hours of stand-by at 800 ma Auxiliary Output Required Transformer: 16 VAC, VA Cabinet Dimensions: 7" high 9" wide 3" deep ( mm) Cabinet Colour: light beige PC500RK Keypad 12-key keypad Three one-touch Zones: [F], [A], [P] 3 Status Lights: Ready, Armed, System 4 Zone Lights Keypad dimensions: 4.5" high 4.5" wide 1" deep (114mm 114mm 25.4mm) Keypad Colour: Mist SL-40 Keypad 12-key keypad Three one-touch Zones: [F], [A], [P] 3 Status Lights: Ready, Armed, System 4 Zone Lights All new slimline design Keypad dimensions: 4.75" high 2.75" wide 1.2" deep (120mm 70mm 30mm) Keypad Colour: Designer White with Grey display 3

5 INSTALLATION Mounting the Control Panel Select a dry location close to an unswitched AC source, a ground connection, and the telephone connection. Remove the printed circuit board, mounting hardware and keypad from the cardboard retainer inside the control panel cabinet. Before attaching the cabinet to the wall, press the four white nylon printed circuit board mounting studs into the raised mounting holes from the back of the cabinet. Also, secure the ground screw to a hole in the cabinet. Hold the cabinet in position and pull all wires into the cabinet. Mount the cabinet securely to the wall using the mounting screws provided. It is recommended that appropriate wall anchors be used when securing the cabinet to drywall, plaster, concrete, brick or other similar surfaces. Press the PC560 Control Panel onto the nylon mounting studs. Pull all cables into the cabinet and prepare them for connection. Mounting the Keypad The PC560 Control Panel is controlled with the PC500RK or SL-40 Keypad. The Keypad should be located close to the designated Entry-Exit door and mounted at a height convenient for all users. Disassemble the keypad by pressing gently on the locking tab found on the bottom of the unit. With the tab disengaged, pull the backplate from the keypad. Prepare a hole in the wall at the desired location and pull the keypad wiring through the hole. Hold the backplate in position and pull the wires through the large opening in the backplate. Mount the backplate to the wall using the hardware provided; it is recommended that plastic wall anchors be used. When mounting the backplate, ensure that it is straight and level. Prepare all wires for connection and connect the keypad wires to the in-wall wiring; refer to the Wiring Diagram in the back of this manual. Align the keypad with the mounting tabs on the top of the backplate. With the top mounting tabs engaged, swing the keypad down and engage the bottom locking tab. Ensure that the top mounting tabs and the bottom locking tab are securely engaged. SL-40 Keypad PC500RK Keypad LOCKING TAB Ready Armed System LOCKING TAB Zone 1 Zone 2 Zone 3 Zone 4 SL-40 KEYPAD BOTTOM VIEW PC500RK KEYPAD BOTTOM VIEW ENGAGE TOP TABS FIRST ENGAGE TOP TABS FIRST WALL RE-ASSEMBLY OF SL-40 KEYPAD SIDE VIEW (WIRES NOT SHOWN FOR CLARITY) WALL RE-ASSEMBLY OF PC500RK KEYPAD SIDE VIEW (WIRES NOT SHOWN FOR CLARITY) SWING KEYPAD DOWN TO ENGAGE LOCKING TAB SWING KEYPAD DOWN TO ENGAGE LOCKING TAB 4

6 Wiring NOTE: Complete all wiring to the control panel before applying battery or AC power. Burglary Zone Wiring Burglary zone definition, (for example, Delay, Instant, 24-Hour, and so on) is programmed using the keypad. Refer to Programming Guide Section [01]. NOTE: To help prevent false alarms, all zones are automatically bypassed for 120 seconds on power-up to allow detectors to settle. Z1 COM Z2 NC NC EOL RESISTOR LOOPS USING NO & NC DEVICES NO NC EOL RESISTOR LOOPS USING NC DEVICES ONLY END OF LINE END OF LINE RESISTOR RESISTOR 5600Ω 0.5W 5600Ω 0.5W Burglary Zone Wiring Chart Maximum wire length to Wire End of Line Resistor Gauge (feet/meters) / / / / / 2377 Figures are based on maximum loop resistance of 100 ohms. Auxiliary Power Connection The Auxiliary Power Supply can be used to power motion detectors and other devices that require 12 VDC. The total load for the Auxiliary Power Supply must be calculated for all devices connected across the AUX+ and AUX-, AUX+ and STR terminals, and for devices connected between the AUX+ and PGM terminals. The output current cannot exceed 800 ma when using a 40VA transformer. PGM OUT Terminal Connection The PGM OUT terminal is a switched negative output which can be controlled by various programming options; refer to Programming Guide Section [04]. Devices controlled by the PGM OUT terminal must be connected between the PGM OUT terminal and the AUX+ terminal. 5

7 STR Terminal Connection The STR (strobe output) terminal is a normally open output that will switch to ground when activated. This output will be activated when a zone alarm or tamper alarm is generated while the system is armed. The output will remain activated until the system is disarmed. Devices controlled by this output must be connected between STR and the AUX+ terminal. KEY Terminal Connection The KEY terminal may be programmed for keyswitch operation or for use as a tamper zone. If the KEY terminal is used as a tamper zone, the zone is wired as a typical burglary zone. The tamper zone is active at all times and will generate alarm and trouble conditions even while the system is disarmed. NOTE: An end-of-line resistor must be connected between the KEY and COM terminals even if the tamper zone is not used. KEYSWITCH OPERATION TAMPER ZONE N.O. CONTACTS TAMPER ZONE N.C. CONTACTS KEY COM KEY COM KEY COM MOMENTARY OR MAINTAINED CONTACT KEYSWITCH END OF LINE RESISTOR 5600Ω 0.5W END OF LINE RESISTOR 5600Ω 0.5W END OF LINE RESISTOR 5600Ω 0.5W Battery Connection The control panel will not power up on DC (battery) power only. With the battery connected, apply AC power to power up the panel. If the battery is connected in reverse, the 5 A battery fuse will open and will need to be replaced. The battery charging voltage is factory set to 13.8V and normally needs no adjustment. If the battery charging voltage is out of adjustment, contact your service representative. If AC power is OFF and the battery voltage drops to approximately 9.5 V or lower, the battery will be automatically disconnected and the system will power down. To power up again, AC power will have to be re-established. This feature is designed to prevent damage to the battery due to deep discharging. AC Power Wiring Complete all wiring to the control panel before connecting AC power or the battery. The transformer should not be connected to an outlet that is controlled by a switch. Telephone Line Wiring Do not connect the alarm communicator to telephone lines intended for use with facsimile (fax) machines. These lines may incorporate a voice filter which disconnects the line if other than fax signals are detected. This may result in incomplete transmissions from the alarm communicator. 6

8 KEYPAD FUNCTIONS Introduction The Keypad provides complete control of the PC560 control panel. The system can be completely programmed from the keypad. The 4 zone lights provide alarm and status indication for the alarm circuits, and three function lights advise the user of system status. The built-in sounder lets the user hear correct key entries and other alert signals. Keypad alarms may be activated by pressing and holding the [F], [A] or [P] Keys. Note that all keypad entries are made by pressing one key at a time. Master Code A default Master Code 1234 is factory programmed into the PC560. The Master Code is used to arm and disarm the system, to silence the bell or siren after an alarm, and to program additional Access Codes. The Master Code may be changed by the user through the [ ][5][Master Code] Program Access Codes command. Installer s Programming Code A default Installer s Programming Code 0560 is programmed into the PC560. Using this code and the [ ][8] command, the installer can perform programming functions. This code should be changed by the installer after the system is installed. Arming Before arming the system, close all protected doors and windows and stop movement in areas protected by motion detectors. If the System light is on, check for possible trouble conditions (refer to [ ][2]: Display Troubles) and correct the condition. Ensure that any bypassed zones are bypassed intentionally; refer to [ ][1][Access Code]: Bypass Zones. If the Ready light is not on, one or more zones are open; the system can only be armed when the Ready light is ON. To arm the system, enter a 4-digit Access Code. As each digit is entered, the keypad sounder will beep. When the Access Code has been entered, the Armed light will come ON and the keypad will beep 6 times. If the Access Code has been entered incorrectly, the keypad will sound a single long tone; press the [#] Key and enter the Access Code again. When an Access Code has been entered and the Armed light is ON, leave the premises through the designated Entry-Exit door before the Exit Delay expires. At the end of the Exit Delay, all lights on the keypad will be shut OFF except for the Armed light. The default setting for the Exit Delay is 60 seconds. Refer to Programming Section [01] Zone Definitions for information on zone types that are affected by the Exit Delay. Also refer to Programming Section [02] for instructions on changing the Exit Delay. If an alarm occurs during the armed period, the Zone Light for the affected zone will remain ON until the system is disarmed. Auto-Bypass/Home-Away Arming If an Access Code is entered and the Exit-Entry zone is not activated during the Exit Delay, the system will arm with all Home-Away zones automatically bypassed. If the Exit-Entry zone is activated during the Exit Delay, the Home-Away zones will not be bypassed. If a standard Delay zone is activated while the system is armed, all automatic bypasses will be removed. This feature is designed for the user who wishes to remain at home with the system armed. When this feature is enabled, the user does not have to manually bypass the interior zones. At-Home Arming When [ ][9] is entered to arm the system, the system will arm as described above in Auto-Bypass/Home-Away Arming. However, an exit may be made through the Entry-Exit Zone during the Exit Delay; at the end of the Exit Delay, the system will be armed and Home-Away zones will be automatically bypassed. Note that the Entry Delay will still be applied to standard Delay zones. 7

9 Disarming Enter the premises through the designated Entry-Exit door. The keypad will be sounding a tone to indicate that the system must be disarmed. Go to the keypad and enter an Access Code. If an error is made entering the code, press the [#] Key and enter the code again. The Armed light will be shut OFF and the keypad sounder will be silenced. An Access Code must be entered before the Entry Delay expires or an alarm will sound. To change the Entry Delay, refer to Programming Section [02]. If an alarm occurred while the system was armed, the System light and the zone lights of the zones that went into alarm will FLASH for two minutes. Press the [#] Key to cancel the flashing display and to return the system to the Ready mode. Refer to [ ][3]: Alarm Memory Display. Important Note about Keypad [ ] Commands The [ ] commands will not function when the bell or siren is active. In order to use the [ ] functions, an Access Code must first be entered to silence the alarm. [ ]+[0]: Quick-Arm The Quick-Arm feature allows a user to enter [ ][0] to arm the system. This command is designed to allow someone to arm the system without that person having to be provided with an Access Code. When [ ][0] is entered, the Exit Delay will begin and the user may exit the premises through the Entry/Exit door. At the end of the Exit Delay, the system will be fully armed; activating any zone will cause an alarm. [ ]+[1]+[Access Code]: Zone Bypassing A bypassed zone will not cause an alarm. Use zone bypassing when access is needed to part of a protected area when the system is armed, or if damage to sensors or wiring cannot be repaired immediately. The system may be armed with one or more zones bypassed even if the zones are open. With the system disarmed, enter [ ][1][Access Code] to display the bypassed zones; the zone lights of bypassed zones will come ON. Ensure that any zone displayed as being bypassed is intentionally bypassed. Zone bypasses are automatically cancelled when the system is disarmed. To Bypass Zones: Enter [ ][1][Access Code]; the System light will FLASH. Enter the number of the zone to be bypassed; the corresponding zone light will come ON to indicate that the zone is bypassed. To remove a bypass, enter the zone number and its zone light will be shut OFF. When all desired zones are bypassed, press the [#] Key to return to Ready. [ ]+[2]: Display Trouble Conditions The PC560 continuously monitors a number of trouble conditions. If one of these conditions occurs, the keypad System light will come ON and the sounder will sound two short beeps every 10 seconds. To silence the sounder, press the [#] Key; the sounder will be silenced but the System light will remain ON until the trouble condition is cleared. Refer to Programming Section [13] Maintenance Codes for a list of trouble conditions that can be reported to the monitoring station. To display trouble conditions, enter [ ][2]. Trouble conditions are represented with the zone lights: Zone Light 1 Battery Trouble. If the battery is disconnected, its voltage is low or the battery fuse is open, a trouble will be displayed and can be reported. 2 AC Failure. If AC power is removed from the system, an AC trouble will be displayed. 3 Tamper Zone. Zone Light 3 will come ON when the Tamper Zone is activated and will remain ON until the zone is restored. NOTE: The system cannot be armed until the Tamper Zone is restored. 4 Unsuccessful Communication Attempt. If the digital communicator cannot communicate with the monitoring station after 8 attempts, a trouble is generated. If a later attempt at communication is successful, the trouble is cleared. The trouble can also be cleared by pressing the [#] Key to exit from the Display Trouble Conditions mode. 8

10 NOTE: If only an AC Failure trouble is present, the keypad sounder will not beep. [ ]+[3]: Display Alarm Memory Alarms caused during the previous armed period are stored in memory. To display the zones that went into alarm, enter [ ][3]. The System light will FLASH and the alarms will be displayed on the flashing zone lights. NOTE: The alarm memory will be cleared the next time the system is armed. [ ]+[4]: Bell Test Entering this command will sound the siren and turn ON all the keypad lights for 2 seconds. [ ]+[5]+[Master Code]: Program Access Codes The [ ][5][Master Code] command allows the user to program the Master Code and 3 additional Access Codes. Programming Access Codes: Enter [ ][5][Master Code]. The Ready, Armed and System lights will FLASH and the zone lights will indicate which Access Codes have been programmed and which Access Code is presently being programmed: Zone Light Access Code is... OFF not programmed ON steady programmed Flashing presently being programmed When the [ ][5][Master Code] command is entered, Zone Light 1 will be ON to indicate that the Master Code is programmed with the factory default code. Changing or Adding a Code To change Access Codes 1 to 4, enter the number of the code to be changed; the corresponding zone light will begin to FLASH. Enter a new 4-digit Access Code; do not press [ ] or [#] when entering the code. After the code is entered, the keypad will beep 3 times and the zone light will stop flashing and remain ON. If an existing code is being changed, the new code will replace the old one. If another code is to be changed, press the number key for the code to be programmed and enter the new 4-digit code. When all desired changes are complete, press the [#] Key to return to Ready. Erasing a Code To erase a code, enter [ ][5][Master Code]. Enter the number of the code to be erased; the zone light for the code will FLASH. Enter [ ] to erase the Access Code. NOTE: Do not erase the Master Code! If the Master Code is accidentally erased, reset the system s programming to the factory default settings. Refer to Resetting Programming to the Factory Default Settings for instructions on restoring the system s factory default programming. [ ]+[6]: Door Chime On/Off The Door Chime feature causes the keypad to beep whenever a Delay or Instant Zone is activated. This feature is useful if the Entry/Exit door or doors are out of view, and the user desires an indication of when the door zones are opened and closed. The Door Chime feature only functions when the system is disarmed. The Door Chime feature may only be turned on or off while the system is disarmed. To turn the Door Chime feature on or off, enter [ ][6]. If the feature is being turned ON, the keypad sounder will beep 3 times. If the feature is being turned OFF, the sounder will emit a single long tone. [ ]+[8]+[Installer s Code]: Installer s Programming Command The PC560 is programmed from the keypad by using commands in the [ ][8][Installer s Code] section. These commands are described in detail in the Programming Section of this manual. The default Installer s Code is [0560]. 9

11 [ ]+[9]: At-Home Arming Entering [ ][9] will arm the system with all Home-Away zones automatically bypassed. When the system is armed using the [ ][9] command, the Armed light will FLASH to indicate that he system has been armed with the At-Home Arming option. Important Note about Keypad [ ] Commands The [ ] commands will not function when the system is in the disarmed state and the bell or siren is active. In order to use the [ ] functions, an Access Code must first be entered to silence the alarm. Keypad Zones Three types of alarm may be activated by pressing and holding a single key on the keypad. For these alarms to be transmitted, Priority Alarm Reporting Codes must be programmed in Section [13]. [F] Press and hold the [F] Key for 2 seconds to sound an [F] Key alarm. The siren will sound a pulsed tone, and the alarm will be reported to the monitoring station. The keypad will sound a series of short beeps once the system has accepted the alarm. [A] Press and hold the [A] Key for 2 seconds to generate an [A] Key alarm. An alarm will be transmitted to the monitoring station, but the siren will not sound when this function is activated. The keypad will sound a series of short beeps once the system has accepted the alarm. [P] Press and hold the [P] Key for 2 seconds to generate a [P] Key alarm. An alarm will be transmitted to the monitoring station. The [P] Key alarm may be programmed as either silent or audible; refer to Programming Section [05]. When programmed as audible, the bell or siren will sound a steady alarm tone and the keypad will sound a series of short beeps once the system has accepted the alarm. When programmed as silent, the bell or siren will not sound on alarm and the keypad will not beep to indicate that the system has accepted the alarm. Adjusting the Keypad Sounder Tone and Backlighting The sounder tone and the lighting behind the keys for each Keypad may be individually adjusted. The sounder tone may be set as high, low, or no tone at all. The backlighting can be set at medium or high brightness, or it may be turned off. To adjust the Keypad s sounder, press and hold the [#] Key; after two seconds, the sounder will begin to beep. With each beep, the tone of the beep will increase or decrease. When the desired tone is achieved, release the [#] Key. To adjust the Keypad s backlighting, press and hold the [ ] Key. The zone and status lights will be shut off, and the Keypad will beep as each of the three backlighting levels is shown: medium, high and off. When the desired level is reached, release the [ ] Key. Press the [#] Key to return to the Ready mode. If all power to the system is shut off, each Keypad s tone and backlighting will be restored to the factory settings. NOTE: WARNING Some models of the PC560 have a special lockout feature that prevents the control panel from being reset to the factory default programming. Call DSC Australia if you are attempting to take over a system installed by another security company. 10

12 PROGRAMMING GUIDE With the system disarmed, enter [ ][8][Installer s Code]. The system can only be programmed while it is disarmed. The default Installer s Code is [0560]. The Installer s Code should be changed after the system is installed; refer to Programming Section [03]. When the Installer s Programming Command is entered, the Armed light will come ON and the System light will FLASH to indicate that the system is ready for programming. NOTE: If no key entry is made for 2 minutes, the system will return to the Ready mode and the Installer s Programming Command will have to be entered again. With the Armed light ON and the System light flashing, enter 2 digits for the Section to be programmed. The Programming Sections are numbered from [01] to [14], and each section is programmed independently. Once the 2 digits for the section to be programmed are entered, the keypad will beep 3 times, the Ready light will come ON and the Armed light will be shut OFF; the system is now ready to accept data for the selected section. In sections that contain groups of 2-digit numbers, the keypad will beep twice after each 2-digit number is entered. To change the first digit in a section, enter a new digit from the keypad. If you wish to keep the first digit unchanged, enter the same number. When all data for the section is completely entered, the keypad sounder will beep several times to indicate that all expected data has been entered. When a section is completely programmed, enter the number of the next section to be programmed. Sections [05] through [07]: Selecting System Functions These sections allow you to enable or disable various system functions. Refer to the Programming Worksheets to see which functions are represented by the Zone Lights. To enable or disable a feature, press a number from 1 to 4 to turn the corresponding zone light ON or OFF. When all selections have been made, press the [#] Key to save the changes and return to the program mode. HEX Data Programming Certain programming entries may require the entry of data in HEX (hexadecimal, or base 16) format. HEX numbering uses the digits 0 through 9 and the letters A through F. The letters A through F are represented by the number keys 1 through 6. To enter data in HEX format, first press the [ ] Key. The Ready and System lights will FLASH. Enter the HEX value, then press the [ ] Key again to return to the normal data entry mode; the Ready light will stop flashing, and the System light will continue to flash. To enter HEX numbers: A Enter [ ][1][ ] D Enter [ ][4][ ] B Enter [ ][2][ ] E Enter [ ][5][ ] C Enter [ ][3][ ] F Enter [ ][6][ ] Enter [ ] before and after each digit. The last digit in each section does not require the last asterisk ( ) to be entered. Resetting Programming to the Factory Default Settings The system may be reset to its factory default programming by following this procedure: 1 Remove all power, AC and battery, from the PC560 2 Remove all wiring connections from the PGM OUT and Zone 1 terminals 3 Short the PGM OUT and Zone 1 terminals together 4 Apply power to the PC560 and wait for 10 seconds 5 After approximately 10 seconds, the keypad sounder will beep and Zone Light 1 will come ON 6 Remove all power, AC and battery, from the PC560 7 Remove the short between the PGM OUT and Zone 1 terminals 8 Re-connect original wiring to the PGM OUT and Zone 1 terminals 9 Restore power to the PC560; the Programming Sections have now been restored to the factory default settings 11

13 PROGRAMMING SECTIONS [01] Zone Definitions Enter four 2-digit numbers in this section to determine the operating characteristics of each zone. Zone Definitions: Digit 1 The first digit of each Zone Definition determines each zone s audible alarm characteristics. When programmed as audible, the siren will sound on alarm; when programmed as silent, the siren will not sound on alarm. Note that zone response times are factory set at 500 ms. Zone Definitions: Digit 2 Digit 2 determines the zone type as described below: [0] Standard Delay: The Standard Delay Zone is normally used for Entry/Exit doors. The Exit Delay starts when the system is armed; the zone may be opened and closed during the delay without causing an alarm. When the Exit Delay expires, opening the zone will start the Entry Delay. During the Entry Delay, the keypad buzzer will sound steadily to indicate that the system should be disarmed. If the system is disarmed before the Entry Delay expires, no alarm will be generated. Entry and Exit Delay times may be independently programmed for 1 to 255 seconds in Section [02]. The default settings are 60 seconds for the Exit Delay, and 15 seconds for the Entry Delay. NOTE: Do not program the Entry or Exit Delays with [000]. [1] Instant: Instant Zones are normally used for door and window contacts. Instant Zones have the standard Exit Delay, but will generate an instant alarm when opened after the Exit Delay expires. Refer to Section [02] for information on programming the Exit Delay; the default setting for the Exit Delay is 60 seconds. [2] Interior: Interior Zones are normally used with interior motion detectors and have the standard Exit Delay. The zone will also have the standard Entry Delay provided that a Delay Zone has been activated before the Interior Zone. If the premises are entered without coming through a Delay zone and an Interior zone is tripped, an instant alarm will be generated. [3] Home-Away with Delay: Home-Away Zones operate similarly to Interior Zones with the following additional feature: if the system is armed and a Delay zone is not activated during the Exit Delay time, the Home-Away with Delay zones will be automatically bypassed. This feature allows the system to be armed with the Home- Away with Delay Zones automatically bypassed so that the user may remain on the premises. If a Delay Zone is activated during the Exit Delay, the Entry Delay will be applied to Home-Away with Delay zones when the Exit Delay expires. If a Home-Away with Delay zone is then activated, the Entry Delay will be initiated. If a Home-Away with Delay zone is activated during the Entry Delay, that zone will follow the Entry Delay before generating an alarm if the system is not disarmed. If the system is armed with the [ ][9] At-Home Arming Command, zones programmed as Home-Away with Delay will remain bypassed until the system is disarmed. [4] 24-Hour Bell: 24-Hour Bell Zones are active at all times and will sound an alarm even if the system is disarmed. 24-Hour Bell Zones will activate the bell/siren output if programmed for audible operation. Alarms on these zones are communicated immediately. [5] 24-Hour Pulsed Alarm: 24-Hour Pulsed Alarm Zones are active at all times and will sound an alarm even if the system is disarmed. Alarms on these zones are communicated immediately. NOTE: 24-Hour Pulsed Alarm Zones should always be programmed as audible so the bell/siren output will be activated when an alarm is generated. If a silent 24-Hour Zone is required, program the zone as [14]. 12

14 [02] System Times Three system times are programmed in Section [02]; each time requires a 3-digit number. Do not press the [#] Key during data entry. Entry Delay (001 to 255 seconds) The Entry Delay determines the amount of time permitted between the activation of a Delay Zone and the disarming of the system. If the system is not disarmed during this delay, an alarm will be generated. Refer to Section [01] for information on which zone definitions are affected by the Entry Delay. The default Entry Delay is 15 seconds. Exit Delay (001 to 255 seconds) The Exit Delay determines the amount of time permitted between entering an Access Code to arm the system and the activation of a Delay Zone to exit the premises. Refer to Section [01] for information on which zone definitions are affected by the Exit Delay. The default Exit Delay is 60 seconds. Bell Cut-Off (001 to 255 minutes) This time determines how long the bell/siren will sound when an alarm is generated. When an alarm is initiated, the bell/siren will sound for this length of time, or until the alarm is silenced by entering an Access Code. The default setting is 10 minutes. [03] Installer s Code The default setting for the Installer s Code is [0560]. It is strongly recommended that the Installer s Code be reprogrammed before installation is complete. Be sure to record the new Installer s Code for later reference. [04] Programmable Output Options (PGM OUT Terminal) The PGM output can be programmed to operate in response to various system operations. When activated, the PGM OUT terminal will switch to ground. [01] Arm/Disarm Status The PGM OUT terminal is turned ON (switched to ground) on arming and remains ON as long as the system is armed. The output is shut OFF when the system is disarmed. [04] Remote Operation When programmed for Remote Operation, the PGM OUT terminal can only be turned ON (switched to ground) or turned OFF on command from the downloading computer. This function may be used to activate a sounder or other device to indicate that downloading is in progress. 13

15 [05] 1st System Option Code When Section [05] is entered, the 4 Zone Lights will be ON or OFF to indicate which options are selected. To turn a Zone Light ON or OFF, press a number from [1] to [4]. If the light was OFF, it will come ON; if the light was ON, it will be shut OFF. LIGHT [1] ON = Momentary-contact Keyswitch Arming OFF = Maintainted-contact Keyswitch Arming [2] ON = [P] Key: silent alarm OFF = [P] Key: audible alarm [3] ON = KEY Terminal as Tamper Zone OFF = Keyswitch Operation Enabled [4] OFF = For Future Use Factory default settings If Momentary-contact Keyswitch Arming is selected, the keyswitch must be opened and then closed to arm or disarm the system. If Maintained-contact Keyswitch Arming is selected, OPEN the key contact to arm the system, and CLOSE the key contact to disarm the system. Turning Zone Light 3 ON programs the KEY Terminal as a Tamper Zone. Refer to the Hook-up Diagram for wiring instructions. [06] 2nd System Option Code Refer to Section [05] for programming information. LIGHT [1] ON = Private line OFF = 40 BPS 4/2 with Parity If the communication format is changed: when programming is complete, remove all power from the system, wait for 10 seconds, and then restore power to the system. [2] ON = 1400 Hz Handshake OFF = 2300 Hz Handshake [3] ON = DLS Answer enabled OFF = DLS Answer disabled [4] ON = Ringback enabled OFF = Ringback disabled Factory default settings If DLS Answer is disabled, the PC560 will not answer calls from a downloading computer. If DLS Answer is enabled, the system will only connect to the downloading computer using the double call technique. The system must be called by the downloading computer, and the computer must allow the telephone line to ring only once or twice. After one or two rings, the downloading computer must hang-up the line and then call the system again within 60 seconds. The system will then answer the second call on the first ring. Note that the double call technique is the only means of connecting to the downloading computer. If Ringback is enabled, the keypad will sound a series of beeps to acknowledge that communications have been completed successfully. The beeps will sound after the system has received the kissoff handshake from the monitoring station s receiver. This is used to indicate to the user that the monitoring station has received communicated events. NOTE: Do not use the Ringback feature if silent zones are programmed on the system. 14

16 Private Line Format The Private Line format will only transmit zone alarms for which reporting codes are programmed in Section [11]; [F], [A] and [P] Key alarms will not be reported by this format. Do not program any reporting codes other than the Alarm Reporting Codes for Zones 1 through 4 and the Tamper Zone. When a zone goes into alarm, the system will dial the telephone number programmed in Section [08]. The system will make up to eight attempts to communicate to the First Phone Number. After eight unsuccessful communication attempts, the system will dial the Second Phone Number programmed in Section [09]. When the call is answered, a double beep will sound on the line to indicate to the listener that a security system is placing a call. Press 3, 6, 9 or # on a touch-tone telephone to have the system transmit the zone or zones that are in alarm. The system will indicate which zone is in alarm by sounding a number of tones. One tone will sound for Zone 1, two tones will sound for Zone 2, and so on. Note that 5 tones will sound for a Tamper Zone alarm. When the system has sounded the tones to indicate which zone is in alarm, it will wait for approximately 5 seconds for the listener to key in a closing handshake. Pressing 3, 6, 9 or # will send a closing handshake to the system. When the system receives the handshake, it will either hang up or will sound additional tones to indicate the next zone that is in alarm. 40BPS Non-Extended 4/2 with Parity Format This communication format requires a 4-digit Account Code to be programmed in Section [10] and 2-digit reporting codes to be programmed in Sections [11], [12] and [13]. When an event is reported, the 4-digit Account Code, the appropriate 2-digit Event Code and a 1-digit parity character are transmitted. Since this format uses parity, only one round needs to be transmitted per event. Ensure that the handshake (Section [06] Light 2) is programmed to match the receiver to which the system will communicate. [07] 3rd System Option Code Refer to Section [05] for programming information. LIGHT [1] ON = Swedish Pulse Dialing OFF = Standard Pulse Dialing [2] OFF = For Future Use [3] OFF = For Future Use [4] OFF = For Future Use Factory default settings Standard Pulse Dialing: 1 is transmitted as one pulse, 2 is transmitted as two pulses, and so on; 0 is transmitted as ten pulses. Swedish Pulse Dialing: 1 is transmitted as two pulses, 2 is transmitted as three pulses, and so on; 0 is transmitted as one pulse. Setting the pulse dialing option will depend on the pulse dialing method used by the telephone company. 15

17 [08] First Phone Number This is the first telephone number the Communicator will dial when an alarm is generated. Enter the telephone number the same way it would be dialled on a touch-tone phone. Press [#] after the last digit to complete the telephone number programming. A pause of 2 seconds can be added by entering HEX D between digits in the phone number. To enter HEX D, press [ ] [4] [ ]. The total number of digits and pauses must not exceed 17. Do not program any HEX digits other than D in the telephone number. NOTE: If the Second Phone Number is to be used, program the First Phone Number first. If only one telephone number is to be used, program the number in Section [08]. [09] Second Phone Number The system will call the Second Phone Number if 8 communication attempts to the First Phone Number are unsuccessful. Refer to Section [08] First Phone Number for programming instructions. [10] Customer Account Code The Customer Account Code is always transmitted to the telephone number to identify the customer. Enter a 4-digit number in Section [10]. Where a zero is required in the account code, enter HEX A [ ] [1] [ ]. Disabling Communications To disable the communicator, program all the reporting codes in Section [11], [12] and [13] with 00 or hexadecimal FF. [11] Zone Alarm and Restoral Reporting Codes When Section [11] is entered, enter ten 2-digit numbers for the Alarm and Restoral Reporting Codes for zones 1 to 4 and the tamper zone. The alarm codes are transmitted when there is an alarm on a zone; the restoral codes are transmitted when the zone is restored and after the Bell Cut-off time has expired, or when the system is disarmed. 24-hour Zones and the Tamper Zone transmit their restoral codes when the zones are restored. [12] Closing and Opening Reporting Codes When the system is armed (closed) or disarmed (opened), a closing or opening reporting code will be transmitted to indicate which Access Code was used to arm or disarm the system. If the Opening After Alarm Reporting Code is programmed, it will be transmitted to the monitoring station on disarming if an alarm occurred during the previous armed period. This feature is useful for installations where openings and closings are not normally reported, but it is desired to have a report on opening if an alarm occurred during the armed period. This feature allows the monitoring station to know that the user is on the premises and is available to receive a report on the alarms that occurred during the armed period. 16

18 [13] Maintenance and Priority Codes Maintenance Codes are transmitted to indicate various trouble conditions and their restorals; Priority Codes are used to indicate the activation of the [F], [A] and [P] keys. Program a 2-digit code for each of the following conditions: Battery Trouble [P] Key alarm [P] Key restore Police Code Battery Trouble Restore [A] Key alarm [A] Key restore Periodic Test Code [F] Key alarm [F] Key restore The Periodic Test Code is transmitted to the monitoring station once every 24 hours. The first transmission will be sent 12 hours after the system is first powered, and then once every 24 hours after the initial transmission. If the Police Code is programmed it will be transmitted to the monitoring station if two or more alarms occur on different zones during the same armed period. The Police Code will be sent immediately after the transmission of the second alarm code. [14] Downloading Access Code This 4-digit code allows the system to confirm that it is communicating with a valid downloading computer. Enter a 4-digit code using the numbers 0 through 9; the hexadecimal numbers A through F may also be used in this code. The default code is [0505]. 17

19 FOR THE RECORD PC560 v1.0a Customer Address Phone Installation Date CONTACTS Name Phone Name Phone Name Phone ZONE INFORMATION Zone Type Protected Area Entry Delay Exit Delay Bell Cutoff KEYPAD ZONES [P] Key Silent Audible NOTES 18

20 PROGRAMMING WORKSHEETS PC560 v1.0a [01] Zone Definitions Page 12 NOTE: When defining zones, assign delay zones first, then assign the other types. Default 0 0 Zone Zone Zone Zone 4 [02] System Times Page 13 Default Digit 1 Digit 2 [0] Audible [0] Standard Delay [1] Silent [1] Instant [2] Interior [3] Home-Away with Delay [4] 24-Hour Bell [5] 24-Hour Pulsed Alarm Entry Delay (seconds) Exit Delay (seconds) Bell Cut-off (minutes) Valid entries are 001 to 255 ; do not enter 000. [03] Installer s Code Page 13 Default [04] Programmable Output Options (PGM OUT Terminal) Page 13 Default 0 1 Programmable Output [01] Arm/Disarm Status [04] Remote Operation (through Downloading) [05] 1st System Option Code Page 14 Default Zone Light ON Zone Light OFF OFF Zone Light 1 Momentary Keyswitch Maintatined Keyswitch ON Zone Light 2 [P] Key: silent alarm [P] Key: audible alarm ON Zone Light 3 KEY Terminal is Tamper Zone Keyswitch operation OFF Zone Light 4 For Future Use NOTE: An end-of-line resistor must be connected between the KEY and COM terminals even if the KEY terminal is not used for keyswitch operation or as a tamper zone. 19

21 PC560 v1.0a [06] 2nd System Option Code Page 14 Default Zone Light ON Zone Light OFF OFF Zone Light 1 Private Line 40 BPS 4/2 with parity ON Zone Light Hz Handshake 2300Hz Handshake OFF Zone Light 3 DLS Answer enabled DLS Answer disabled OFF Zone Light 4 Ringback enabled Ringback disabled If the communication format is changed: when programming is complete, remove all power from the system, wait for 10 seconds, and then restore power to the system. [07] 3rd System Option Code Page 15 Default Zone Light ON Zone Light OFF OFF Zone Light 1 Swedish Pulse Dialing Standard Pulse Dialing OFF Zone Light 2 For Future Use OFF Zone Light 3 For Future Use OFF Zone Light 4 For Future Use [08] First Phone Number Page 16 Enter [0] for the digit 0 in the phone number. Enter [ 4 ] (HEX D) for a 2-second pause between number digits. Enter [#] to end the phone number entry. If only one phone number is to be used, program the number in Section [08]. [09] Second Phone Number Page 16 [10] Customer Account Code Page 16 Enter [ 1 ] (HEX A) for the digit 0 in the account code. For a 3-digit code, enter [0] for the 4th digit. 20

22 PC560 v1.0a [11] Zone Alarm and Restoral Reporting Codes Page 16 For single digit reporting codes, enter [0] as the second digit. Zone 1 Alarm Zone 2 Alarm Zone 3 Alarm Zone 4 Alarm Tamper Alarm Zone 1 Restoral Zone 2 Restoral Zone 3 Restoral Zone 4 Restoral Tamper Restoral Enter [ 1 ] (HEX A) to transmit a 0 (zero = 10 pulses) NOTE: 24-Hour Zone restorals are transmitted when the zone is restored. All other restorals are transmitted after the Bell Cut-off time expires, or when the alarm is silenced by entering an Access Code. [12] Closing and Opening Reporting Codes Page 16 For single digit reporting codes, enter [0] as the second digit. Closing, Access Code 1 Closing, Access Code 2 Closing, Access Code 3 Closing, Access Code 4 Opening, Access Code 1 Opening, Access Code 2 Opening, Access Code 3 Opening, Access Code 4 Opening After Alarm Code Enter [ 1 ] (HEX A) to transmit a 0 (zero = 10 pulses) 21

23 PC560 v1.0a [13] Maintenance and Priority Codes Page 17 For single digit reporting codes, enter [0] as the second digit. Battery Trouble Battery Restore Periodic Test Code [P] Key Alarm [A] Key Alarm [F] Key Alarm [P] Key Restore [A] Key Restore [F] Key Restore Police Code [14] Downloading Access Code Page 17 Default Enter [ 1 ] (HEX A) to transmit a 0 (zero = 10 pulses) This code allows the panel to confirm that a valid downloading computer is requesting access to the panel. 22

24 Ready Armed System Zone 1 Zone 2 Zone 3 Zone 4 HOOK-UP DIAGRAM PC560 INCORRECT CONNECTIONS MAY RESULT IN FUSE FAILURE OR IMPROPER OPERATION. INSPECT WIRING AND ENSURE CONNECTIONS ARE CORRECT BEFORE APPLYING POWER. Before disconnecting the power supply from a general purpose outlet socket, disconnect the telecommunications line plug. DO NOT REPLACE FUSES WITH HIGHER VALUES THAN SHOWN AUX 1 AMP BELL 5 AMP BATT 5 AMP REFER TO ZONE CONNECTIONS BELOW YEL BLK GRN RED TLM-1 TELEPHONE PLUG 240 VAC 50 Hz TRANSFORMER 16VAC 20VA MIN. DO NOT CONNECT TRANSFORMER TO SWITCHED RECEPTACLE. RECOMMENDED TRANSFORMER: BASLER ELECTRIC BE CAA-0002 PROGRAMMABLE OUTPUT LOAD 50mA MAX. STR (STROBE) OUTPUT TO COM: 5600Ω 0.5W END OF LINE RESISTOR MUST BE CONNECTED BETWEEN KEY AND COM TERMINALS IF KEY TERMINAL IS NOT USED TO AUX+ RED BLK + BATTERY 12V 4Ah GELL CELL 12VDC BELL/SIREN 1A MAX. OBSERVE POLARITY! GRN YEL BLK RED LOAD 300mA MAX. OR TO AUX+ BATTERY CAPACITY FOR EMERGENCY STAND-BY IS AT LEAST 4 HOURS IF THE TOTAL LOAD (BELL & AUX OUTPUTS) IS 800mA OR LESS. BATTERY CHARGE CURRENT IS 360mA MAX. RECOMMENDED BATTERY: YUASA NP4-12. PC500RK KEYPAD SL-40 KEYPAD 3 MAXIMUM PER SYSTEM Z1 COM Z2 KEY COM NC NC MOMENTARY OR MAINTAINED CONTACT KEYSWITCH EOL RESISTOR LOOPS USING NO & NC DEVICES NO END OF LINE RESISTOR 5600Ω 0.5W END OF LINE RESISTOR 5600Ω 0.5W NC EOL RESISTOR LOOPS USING NC DEVICES ONLY END OF LINE RESISTOR 5600Ω 0.5W PROGRAM KEY TERMINAL CONFIGURATION IN SECTION [05]. IF KEY TERMINAL IS TO BE USED AS A TAMPER ZONE, CONNECT THE ZONE AS SHOWN IN THE "TYPICAL BURGLARY ZONE CONNECTIONS" DIAGRAM. Recognized limited energy cable should be used. Observe local codes as defined by the authority having jurisdication. Refer to Installation and Instruction Manuals for complete operating instructions. Detection devices that require power from the Control Panel should operate over the range of 10.0 to 14.0 VDC. The DSC BRAVO models are recommended motion detectors. The DSC DG-50 is a recommended glassbreak detector. Temperature Range: 0 C to 49 C (32 F to 120 F). Maximum Humidity: 85% relative humidity 23

25 LIMITED WARRANTY Digital Security Controls Ltd. warrants that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls Ltd. shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control of Digital Security Controls Ltd. such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse, alteration or improper application of the equipment. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd. This warranty contains the entire warranty. Digital Security Controls Ltd. neither assumes, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. In no event shall Digital Security Controls Ltd. be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this product. WARNING: Digital Security Controls Ltd. recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected. 24

26 1995 Digital Security Controls Ltd R Flint Road, Downsview, Ontario Canada M3J 2J6 April Telephone: (416) Fax: (416)

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS TABLE OF CONTENTS 1 TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2

More information

Long Range Radio Alarm Transmitter

Long Range Radio Alarm Transmitter TM Long Range Radio Alarm Transmitter INSTALLATION MANUAL Version 1.3W FEATURES Transmits alarm information to a long range radio network Varitech Transmission Format Note: If automatic SIA is used in

More information

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad

More information

Long Range Radio Alarm Transmitter

Long Range Radio Alarm Transmitter W A R N I N G Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. TM

More information

Long Range Radio Alarm Transmitter

Long Range Radio Alarm Transmitter TM Long Range Radio Alarm Transmitter INSTALLATION MANUAL Version 1.3 This manual is for the LINKS2150 software version 1.3 TABLE OF CONTENTS FEATURES 1 Keypad Programmable... 1 EEPROM Memory... 1 Static/Lightning

More information

INSTALLATION MANUAL PC15OO

INSTALLATION MANUAL PC15OO INSTALLATION MANUAL PC15OO This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)

More information

INSTRUCTION MANUAL PC255O

INSTRUCTION MANUAL PC255O INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment

More information

PROGRAMMING WORKSHEETS

PROGRAMMING WORKSHEETS 16 Hook-up Diagram Table of Contents INTRODUCTION 2 Features... 2 Specifications... 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Wiring... 3 Burglary Zone Wiring... 4 Fire Zone Wiring...

More information

INSTRUCTION MANUAL PC255O

INSTRUCTION MANUAL PC255O INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment

More information

INSTALLATION MANUAL PC25OO

INSTALLATION MANUAL PC25OO INSTALLATION MANUAL PC25OO NOTES ON UL INSTALLATION This equipment is UL listed in accordance with UL standard 1023 (Household Burglar Alarm System Units), UL standard 985 (Household Fire Warning Units)

More information

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output:

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output: SPECIFICATIONS Control Panel Specifications 21 zones including: 16 fully programmable supervised zones (EOL resistors) Supervised fire zone 1 auxiliary normally open zone 3 keypad activated zones Audible

More information

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming Master Code The 4 digit Master Code is used for arming and disarming the system, for programming additional access codes, and for changing other features. The Master Code will be supplied to you by your

More information

INSTALLATION MANUAL. PC3OOO Version 7.6W

INSTALLATION MANUAL. PC3OOO Version 7.6W INSTALLATION MANUAL This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device

More information

System Introduction. 1.1 Specifications

System Introduction. 1.1 Specifications System Introduction S E C T I O N 1 1.1 Specifications Downloading Software Support PC585 uses DLS-1 v6.5 and up. Flexible Zone Configuration Four fully programmable zones; system expandable to eight zones

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

INSTALLATION MANUAL DV8OOO. Software Version 1.0

INSTALLATION MANUAL DV8OOO. Software Version 1.0 INSTALLATION MANUAL DV8OOO Software Version 1.0 *DVACS is a registered trade mark of Electro Arts Limited and covers a wide variety of products. Full DVACS compatability applies only when the Sur-Gard

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

System Introduction. 1.1 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1 System Introduction S E C T I O N 1 1.1 Specifications Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E... 5$1*(5( DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS General Description... 2 Standard and Optional Parts List... 2 Feature Definitions... 3 Comments about the 8600E... 4 Terminal

More information

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1 1.1 PC5015 Specifications System Introduction S E C T I O N 1 Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance

More information

PC155O. Installation Manual W A R N I N G. Software Version 4.1 DLS-1 V6.5 and later

PC155O. Installation Manual W A R N I N G. Software Version 4.1 DLS-1 V6.5 and later Installation Manual PC155O Software Version 4.1 DLS-1 V6.5 and later W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations

More information

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION...2 STANDARD AND OPTIONAL PARTS LIST...2 FEATURE DEFINITIONS...3 TERMINAL DRAWING AND SPECIAL NOTES...4

More information

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging 1.1 Specifications System Introduction S E C T I O N 1 Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master,

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: -961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

PC56O. Instruction Manual

PC56O. Instruction Manual Instruction Manual PC56O Software Version 1.OA W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the

More information

Quick Reference Guide

Quick Reference Guide WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

Programming Worksheets

Programming Worksheets WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

636 and 646 Keypads. User s Manual

636 and 646 Keypads. User s Manual 636 and 646 Keypads 636 646 User s Manual Table Of Contents Basic Operation... 2 Access Codes... 4 Arming & Disarming... 5 Panic Zones... 11 Key Access Programming... 12 Additional Features... 13 Trouble

More information

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone... 1 2 Content 1. Introduction to the IDS 805... 7 1.1 Features...7 2. Installation and Wiring...8 3. End-of-Line Resistors/Tamper per Zone...9 4. Connecting the Telephone Communicator...10 5. Programmable

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

Paradox Security System Graphic Dept - PRINTED IN CANADA. keypad entries in memory. arming permits movement in pre-selected,

Paradox Security System Graphic Dept - PRINTED IN CANADA. keypad entries in memory. arming permits movement in pre-selected, 970213-0001 ESPRIT 727 U LISTED User Manual VERSION 3.3 P R D O X S E C U R I T Y S Y S T E M S Paradox Security System Graphic Dept - PRINTED IN CANADA READY The green LED must be " on", indicating all

More information

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher IMPORTANT WARNING:This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

Digiplex LED Keypads. User s Manual

Digiplex LED Keypads. User s Manual Digiplex LED Keypads User s Manual TABLE OF CONTENTS INTRODUCTION... 6 1.1 Legend...6 BASIC OPERATION... 7 2.1 Auditory Feedback (Beep Tones)...8 2.2 Keypad Indicator Lights...8 2.3 LED Keypads...8 2.4

More information

LCD and 16-Zone LED Keypads. User s Manual

LCD and 16-Zone LED Keypads.   User s Manual LCD and 16-Zone LED Keypads 1689 1641 16-Zone LED Keypad LCD Keypad User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION...3 2.0 BASIC OPERATION...4 2.1 Keypad Indicator Lights... 4 2.2 Visual Feedback...

More information

CC408. Quick Reference Guide Solution 880

CC408. Quick Reference Guide Solution 880 CC408 EN Quick Reference Guide Solution 880 CC408 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Press CODE key + * + 2468 + 1 (also try 2121) Installer Options Move to location Program location Exit Program Default Panel Hex Program Code + * + Installer Code + 1 = Enter Programming

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

INSTALLATION MANUAL & PROGRAM RECORD SHEET

INSTALLATION MANUAL & PROGRAM RECORD SHEET INSTALLATION MANUAL & PROGRAM RECORD SHEET TABLE OF DESCRIPTION CONTENTS PAGE WIRING MANUAL 2-6 MENU CHART 7 INSTALLER FUNCTIONS 8 MENU 1 SYSTEM TIMES 9 MENU 2 ZONE CONFIGURATION 10-14 MENU 3 SYSTEM OPTIONS

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01 B ISSUED DEC 2004 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

NetworX Series NX-4V2 Control Panel Installation and Startup

NetworX Series NX-4V2 Control Panel Installation and Startup NetworX Series NX-4V2 Control Panel Installation and Startup 2005 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every

More information

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system

More information

System Manual W A R N I N G. PC6O1O Software Version 2.1

System Manual W A R N I N G. PC6O1O Software Version 2.1 System Manual W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

Destiny Destiny Owners Manual

Destiny Destiny Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

Table of Contents. Appendix A Special Characters 31

Table of Contents. Appendix A Special Characters 31 Table of Contents Introduction 2 Section 1: General System Operation 3 1.1 Getting to Know Your System... 3 1.2 How to Arm... 4 1.3 Alternate Arming Methods... 5 1.4 Disarming... 6 1.5 Alarm Memory...

More information

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

System Programming Guide

System Programming Guide & System Programming Guide Software Versions 4.4 (728ULT) and 4.1 (738ULT) Installer Code (Default - 728 Ultra: 282828; 738 Ultra: 383838) Full access to programming, except user access codes (PINs). No

More information

Digiplex LED Keypads User s Manual

Digiplex LED Keypads User s Manual KLEDEU03.fm Page -1 Friday, May 4, 2001 11:25 AM Digiplex LED Keypads User s Manual KLEDEU03.fm Page 0 Friday, May 4, 2001 11:25 AM KLEDEU03.fm Page 1 Friday, May 4, 2001 11:25 AM TABLE OF CONTENTS 1.0

More information

All-In-One Wireless Security System V1.0. Model #: MG-6060

All-In-One Wireless Security System V1.0. Model #: MG-6060 All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual DRAFT Table of Contents Introduction... 5 About Magellan and this Manual... 5 Conventions... 5 Specifications...

More information

Installation Instructions

Installation Instructions g 466-2339A October 2009 2009 GE Security, Inc. Introduction This is the GE. Installations should only be done by trained professionals. Use this document to install the system with default settings that

More information

10-Zone Spectra LED Keypads

10-Zone Spectra LED Keypads 10-Zone Spectra LED Keypads User s Guide TABLE OF CONTENTS Introduction... 5 Basic Operation... 6 Auditory Feedback... 6 Keypad Indicator Lights... 8 Zone Display... 8 Alarm Memory Display... 8 Trouble

More information

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2 0$(6752 0$(6752 6 and 10 Zone Alarm Control Panel Programming Guide,1752'8&7,21 The Maestro-600 and Maestro-1000 alarm control panels enable reduced number of programming steps. End-users can access most

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

642 LCD Keypad. User Manual

642 LCD Keypad. User Manual 642 LCD Keypad User Manual Table of Contents Introduction...1 Legend... 1 Basic Operation...2 Keypad Indicator Lights... 2 Visual Feedback... 2 Auditory Feedback... 3 Info List... 4 Access Codes...5 User

More information

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch

More information

Using Your GEM-P400 Security System H

Using Your GEM-P400 Security System H Using Your GEM-P400 Security System H 1 2 3 4 AR MED STATU S 1 2 This page left blank intentionally Introduction Congratulations on your purchase of an advanced GEMINI-P400 Security System. Meticulously

More information

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

NetworX Series NX-6 CONTROL PANEL. Installation and Startup NetworX Series NX-6 CONTROL PANEL Installation and Startup 25 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every possible

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Program Location 1. Hold 8 key for 3 seconds, keypad will beep 2. Enter 4 5 6 7 8 9, display should show dash on display 1. Press [B/A] key display will show 3 dashs 2. Enter 3-digit location

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01C ISSUED APRIL 2005 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide ICP-CC488 EN User s Guide ICP-CC488 Control Panel ICP-CC488 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc. ( Bosch

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

WARNING Software Version 2.3 / DLS-1 v6.7 and up See Back Cover for New Features in Version 2.3

WARNING Software Version 2.3 / DLS-1 v6.7 and up See Back Cover for New Features in Version 2.3 WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

NX-4V2 Control Panel Installation Instructions

NX-4V2 Control Panel Installation Instructions 4V2 Control Panel Installation Instructions Introduction This is the 4V2-Control Panel Installation Instructions. Installations should only be done by trained professionals. Use this document to install

More information

Fire Command Keypad. XR5 User s Guide

Fire Command Keypad. XR5 User s Guide Fire Command Keypad XR5 User s Guide Silencing an Alarm While the fire alarm horns, strobes, or sirens are sounding use one of the following methods to silence the alarm depending on which type of keypad

More information

PowerSeries. PC1616/PC1832/PC1864 version 4.1. Installation Guide

PowerSeries. PC1616/PC1832/PC1864 version 4.1. Installation Guide PowerSeries PC1616/PC1832/PC1864 version 4.1 Installation Guide Note to Installer:Center pages contain important end user information. Leave with End User. WARNING: This manual contains information on

More information

ESPRIT. 616/626 KEYPADS. User Manual P R D O X. Model 626 READY S E C U R I T Y S Y S T E M S UM ESPRIT

ESPRIT.  616/626 KEYPADS. User Manual P R D O X. Model 626 READY S E C U R I T Y S Y S T E M S UM ESPRIT ESPRIT 616/626 KEYPADS BYP 1 2 4 7 0 3 5 6 8 9 11 10 AWAY CLEAR ENTER 2ND TRBL MEM STAY READY ARMED 12 User Manual Model616 ESPRIT LISTED Model 626 READY ARMED LISTED U P R D O X S E C U R I T Y S Y S

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

ESPRIT 616/626 KEYPADS. User Manual P R D O X S E C U R I T Y S Y S T E M S. Model 626 READY UM ESPRIT PRINTED IN CANADA 2ND TRBL

ESPRIT 616/626 KEYPADS. User Manual P R D O X S E C U R I T Y S Y S T E M S. Model 626 READY UM ESPRIT PRINTED IN CANADA 2ND TRBL ESPRIT 616/626 KEYPADS LISTED U User Manual READY ARMED Model616 2ND TRBL MEM BYP 1 2 4 7 0 3 5 6 8 9 11 10 AWAY STAY CLEAR ENTER 12 Model 626 READY ARMED ESPRIT P R D O X S E C U R I T Y S Y S T E M S

More information

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide ICP-CC408 EN User s Guide ICP-CC408 Control Panel ICP-CC408 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc, ( Bosch

More information

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction. INTRODUCTION The PC4020 is a highly flexible and versatile control which will enable the installer to meet the most demanding security requirements. The heart of the system is the main control panel, designated

More information

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual Table of Contents Introduction... 3 About Magellan and this Manual... 3 Conventions... 3 Specifications... 3

More information

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup NetworX Series NX-8 Commercial Fire Panel Installation and Startup 2004 GE Security All rights reserved. Printed in the United States of America. These instructions do not purport to cover all details

More information

Digiplex Control Panel (DGP-848) - V4.0

Digiplex Control Panel (DGP-848) - V4.0 Digiplex Control Panel (DGP-848) - V4.0 DGP-848 Reference and Installation Manual TABLE OF CONTENTS INTRODUCTION... 4 1.0 1.1 Features... 4 1.2 Specifications... 4 INSTALLATION... 5 2.0 2.1 Location &

More information

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002 ELECTRONIC ENGINEERING LTD. PowerWave-16 16 zone Control panel Communicator Users Operating and Programming Guide Version 6.20 P/N 7121240 Rev. B N.A July 2002 Contents Introduction...4 Meet the Crow Alarm

More information

Protégé Eclipse LED Keypad User Manual PRT-KLES

Protégé Eclipse LED Keypad User Manual PRT-KLES Protégé Eclipse LED Keypad User Manual PRT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated Control Technology

More information

L900 series USER MANUAL

L900 series USER MANUAL INTRODUCTION The BLUGUARD Control Panel is designed for simple operation yet provides the maximum protection for you. Please read this manual carefully and follow the instructions contained in this book.

More information

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad... 2 Contents Glossary...7 1. Introduction to the IDS805...8 1.1 Notes...8 2. Understanding the Keypad Indicators...8 3. Operation of the Keypad...9 4. System Information...10 4.1 Programmed Functions...10

More information

Solution Ultima 862 Operators Manual ISSUE 1.10

Solution Ultima 862 Operators Manual ISSUE 1.10 Solution Ultima 862 Operators Manual ISSUE 1.10 Solution Ultima 862 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA486O DOCUMENT ISSUE 1.10 Printed 24 April 2001 This documentation

More information

IDS816 User Manual H Issued January 2009

IDS816 User Manual H Issued January 2009 1 Contents Glossary-------------------------------------------------------------------------------------------------------------------6 1. Introduction to the IDS 816---------------------------------------------------------------------------7

More information

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

IDS S E C U R I T Y IDS816.  User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-02A ISSUED November 2004 VERSION 1.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3.

More information

Independent Zone Control (I.Z.C.)

Independent Zone Control (I.Z.C.) Operation and Installation Guide Independent Zone Control (I.Z.C.) DELAYED INSTANT ARMED 1 2 3 4 7 5 6 8 9 * * fi Radionics R D279A Operation & Installation Guide 46456B Page 2 Copyright 2000 Radionics

More information

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01 DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL 800-6006V1 12/01 System Overview General Information Control Panel Detection Devices You have made a wise decision to protect your family and property

More information

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

IDS800 USER MANUAL. Summary of Operation.   + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay Arm Stay Arm & Go H old down [ 1] for 1 second H old down [ 5] for 1 second H old down [ 6] for 1 second Panic Fire Medical

More information

Installation Manual Version 1.3. Long Range RF Transmitter. How to contact us:

Installation Manual Version 1.3. Long Range RF Transmitter. How to contact us: How to contact us: Technical Support If you have questions or problems when using this product, you can call Technical Support. If you are within the United States or Canada, you can get support by dialing

More information

DESTINY OWNER S MANUAL

DESTINY OWNER S MANUAL DESTINY OWNER S MANUAL DESTINY You have made a wise decision to protect your family and property with the DESTINY Security System. The DESTINY has been designed to provide you with a maximum level of security

More information