1 Benefiting Government, Industry and the Public Through Innovative Science and Technology Barry L. Badders, Jr. P.E. 7 December 2011

2 Part 1 Non-Combustibility Test Part 3 Test for A, B,, and F Class Divisions Part 4 Test for Fire Door Control Systems Part 11 Test for Fire Resisting Division of High- Speed Craft 7 December

3 K.I.S.S. reads like stereo instructions Refer to Current FTP - not the changes 1 st discuss what is currently required Then discuss the changes 7 December

4 International Maritime Organization (IMO) Fire Test Procedure Code (FTP Code) Currently has 9 Parts Part 1 Non-Combustibility Test Part 2 Smoke and Toxicity Test Part 3 Test for A, B,, and F Class Divisions Part 4 Test for Fire Door Control Systems Part 5 Test for Surface Flammability Part 6 Test for Primary Deck Coverings Part 7 Test for Vertically Supported Textiles and Films Part 8 Test for Upholstered Furniture Part 9 Test for Bedding Components 7 December

5 Has 11 Parts Part 1 Non-Combustibility Test Part 2 Smoke and Toxicity Test Part 3 Test for A, B,, and F Class Divisions Part 4 Test for Fire Door Control Systems Part 5 Test for Surface Flammability Part 6 Test for Primary Deck Coverings Part 7 Test for Vertically Supported Textiles and Films Part 8 Test for Upholstered Furniture Part 9 Test for Bedding Components Part 10 Test for Fire-Restricting Materials for High-Speed Craft Part 11 Test for Fire-Restricting Divisions of High- Speed Craft 7 December

6 Where a material is required to be non-combustible, it shall be determined in accordance with this part. Current Current FTP Code: Requires test to ISO 1182:1990 with modified acceptance criteria 7 December

7 Tube Furnace (Cylinder) 150 mm high 75 mm internal diameter Electric heating element Cone-shaped airflow stabilizer on bottom Draught (draft) shield on top Three thermocouples Furnace Specimen Center Specimen Surface Provides a specific design, but states other designs may be used. 7 December

8 7 December

9 Thermocouples Furnace (one): Mid-height and 10 ± 0.5 mm from wall Specimen (two): Geometric center Surface at mid-height and opposite furnace thermocouple 7 December

10 Shape and size: Cylindrical with volume of 76 ± 8 cm 3 50 ± 3 mm high 45 +0, -22 mm Ø Layers Stack to obtain the 50 mm height Loose fill Representative in appearance, density, etc. as in use Non-homogenous? Requires five identical specimens Conditioned (dried) to constant weight 60 C C for 20 h to 24 h 7 December

11 7 December

12 Record the specimen s s weight Stabilize the furnace to 750 ± 5 C The specimen has to be inserted within 5 s Start the timing device immediately following insertion Minimum test time is 30 min Cool specimen in desiccator and weigh with all recovered char, ash and other debris Repeat for 5 specimens 7 December

13 Record mass before and after for each specimen, report the % loss for each and average for the five Record observations relating to the behavior of the specimen Note occurrence and duration of any flaming Defines sustained flaming as 5 s or longer Report the sum of the recorded durations of sustained flaming for each specimen and the average for the five Initial, maximum, and final temperatures Furnace temperature rise Specimen center temperature rise (max-final) Specimen surface temperature rise 7 December

14 Current FTP is more stringent than ISO 1182:1990 Current FTP Average furnace thermocouple rise 30 C C (vs. 50 C) Average surface thermocouple rise 30 C C (vs. 50 C) Mean duration of sustained flaming 10 s (vs. 20 s) Average mass loss 50% 7 December

15 Your conducting a test, on the first specimen, at 2 s into the test t flaming occurs and lasts for 4 s. Flaming occurs again at 10 s and lasts for 4 s. This same pattern repeats at 20 s, 30 s, and 40 s. ISO 1182:1990, Section 7.2.2: Note the occurrence of any sustained flaming and record the duration of such flaming. Sustained flaming shall be taken as the continuous presence of flames caused by the specimen lasting 5 s or longer (see annex B, clause B.9). B.9 Flaming is sometimes difficult to identify. Some specimens exhibit only a continuous glow (corona): this should not be timed d but should, nevertheless, be noted under Observations during the test (see 7.2, clause 9, and annex C). 7 December

16 1. How do you record this observation? 2. What is the application for the criteria? (Recall that we report the sum of the recorded durations of sustained flaming for each specimen and the average for the five) 7 December

17 Adds Appendix with the procedure and a normative reference to ISO 1182 Looks a lot like ISO 1182:2002 Included added definitions Theoretically should yield the same results (within repeatability and reproducibility limits) 7 December

18 Furnace stabilization During the 10 min stabilization, adds maximum deviation from average temperature of not more than 10 C C in 10 min. Other requirements remain Adds control measurement Moisture content Organic content 7 December

19 Adds and observation requirement Start observation of flaming before the specimen is lowered into the furnace. Only test for 30 min No stabilization required to end test 7 December

20 Where products (such as decks, bulkheads, doors, ceilings, linings, windows, fire dampers, pipe penetrations and cable transits) are required to be A or B or F class divisions, they shall comply with this part. Current Current FTP Code: Testing in accordance with Resolution A.754(18) 7 December

21 Changes/corrects the bulkhead and deck sizes Bulkhead 2,400 mm wide x 2,500 mm high Deck 2,440 mm wide x 3,040 mm high 7 December

22 Thermal Radiation Test Supplement to Fire Resistance tests for Windows in A, B,, and F Class Divisions Test in accordance with Resolution A.754(18) Added instrument(s) 7 December

23 Water-cooled heat flux gauge 7 December

24 Criteria 7 December

25 Studies by Stoll and Greene (1958) 7 December

26 Continuous B Class Divisions Optional May be requested by the Administration Test in accordance with Resolution A.754(18) Ceilings Mounted on Horizontal Furnace with 150mm high B class bulkheads between ceiling and furnace. Classified as continuous B-( B ( 0, 15, 30 as applicable) class ceilings. Provides for an exception for tested linings and enclosed construction installed on A class decks 7 December

27 Recommendation on Fire Resistance Tests for A, B and F Class Division Material Applicability Very broad with specific modifications in test procedure to accommodate Pass/Fail Criteria (typical) Structural integrity Insulation integrity 7 December

28 A and B are the More Common Classes of Divisions A-class are steel or equivalent B-class includes composites or stud/sheathing systems H class divisions? Nomenclature Provides Some Insight into Level of Protection Required by Code A-0, A-15, A A-30, A A-60A B-0, B-15, B B-30B Class Society and/or Administration requirements Versatile Test Method (Bulkheads, dampers, windows, etc.) 7 December

29 A class bulkheads - 2,400 mm wide x 2,500 mm high Specific steel construction 4.5 mm plate 65 x 65 x 6.0 mm angle stiffeners spaced 600 mm Specific aluminum construction 6.0 mm plate 100 x 75 x 9.0 mm angle stiffeners spaced 600 mm 7 December

30 7 December

31 A class decks - 2,440 mm wide x 3,440 mm high Specific steel construction 4.5 mm plate 100 x 70 x 8.0 mm angle stiffeners spaced 600 mm Specific aluminum construction 6.0 mm plate 150 x 100 x 9.0 mm angle stiffeners spaced 600 mm 7 December

32 7 December

33 A class doors Test Maximum size (limited by available furnaces) Test in A class bulkhead Stiffeners face away from the furnace Insulation on the fire exposed side Insulation of the same class as door being sought by the door Door opens away from the furnace Sliding doors may need to be tested from both sides 7 December

34 B and F class bulkheads - 2,400 mm wide x 2,500 mm high Panels test a least one at full width B and F class decks - 2,440 mm wide x 3,440 mm high Panels test a least one at full width B and F class doors Test maximum size Test in B class bulkhead Door opens away from the furnace Sliding doors may need to be tested from both sides 7 December

35 Materials Control measurements Non-combustibility Thickness Density Moisture Content Binder Content Conditioning Air dry condition prior to test 7 December

36 Instrumentation Furnace Bare wire (exposed junction) thermocouple Use min of 6 Pressure probe 2 designs to chose from Unexposed temperature 12 x 0.2 mm thin copper disc 30 x 30 x 2 mm insulation pad 7 December

37 7 December

38 7 December

39 7 December

40 7 December

41 Five center and each quadrant (only ones used in average) Two one on each of the central stiffeners Two joints if any Two joint intersections if any Two each joint detail if more than one Additional at the discretion of the testing laboratory or Administration special features or details All in upper half for bulkheads except the lower quadrant thermocouples 7 December

42 7 December

43 Five center and each quadrant (only one used in average) Two vertical (longitudinal) joint, if any Two joint intersections, if any Two each joint detail if more than one Additional at the discretion of the testing laboratory or Administration special features or details All in upper half for bulkheads except the lower quadrant thermocouples 7 December

44 7 December

45 Five center and each quadrant 100 mm from edges, stiffeners, or hardware (only ones used in the average) Two stiffeners (continuous or discontinuous) Additional at the discretion of the testing laboratory or Administration special features or details All in upper half of door except the lower quadrant thermocouples Double leaf door requirements apply to both Windows in doors? 7 December

46 Five center and each quadrant Same locations as five unexposed surface temperature measurements Fixed to the core - peened 7 December

47 Cotton-wool pad Gap gauges 6 mm 25 mm 7 December

48 7 December

49 7 December

50 Furnace Temperature T = 345 log 10 (8t + 1) +20 T is temperature in C, t is time in min 5 min 576 C 10 min 679 C 15 min 738 C 30 min 841 C 60 min 945 C 7 December

51 1000 FURNACE AVERAGE TEMPERATURES Temperature ( C) Standard Curve Furn. Avg Time (min.) 7 December

52 Furnace Pressure Vertical oriented specimens Neutral pressure plane at 500 mm above notional floor Horizontal oriented specimens 20 Pa at a location 100 mm below the specimen Duration of the test A Class 60 min B Class 30 min 7 December

53 Insulation A class division Temperature rise 140 C C for the five thermocouples Temperature rise 180 C C for any thermocouple B class division Temperature rise 140 C C for the five thermocouples Temperature rise 225 C C for any thermocouple Structural core of aluminum alloy Temperature rise 200 C C for the five thermocouples 7 December

54 Integrity For all classes Flaming no flaming on unexposed face Cotton-wool pad no ignition Gap gauges 6-mm gauge pass through and move 150 mm along gap 25-mm gauge pass through 7 December

55 Letter is class rating based integrity duration A class is 60 min B class is 30 min Number is minute-rating based on insulation A-0, A-15, A A-30, A A-60A B-0, B-15, B B-30B 7 December

56 Assembly shows the passage of flames at 43 min, the temperatures are exceeded at 48 min B-30 Assembly shows the passage of flames at 61 min, the temperatures are exceeded at 48 min A-30 Assembly shows the passage of flames at 28 min, the temperatures are exceeded at 59 min No Rating 7 December

57 You competitor is touting an A-120 rating. What does that mean? Do you need one too? 7 December

58 Addressed in Appendix A.I Generally follow requirements for A class doors For windows in doors, test in the door Test maximum size for which approval is sought Five thermocouples center and each quadrant Four thermocouples frame at mid length of each edge Don t t forget the heat flux gauge (Part 3, additional instrumentation) 60-min furnace exposure as previously described 7 December

59 Hose Stream test Optional in FTP but USCG requires it for windows over 100 in 2 Conducted immediately following the furnace exposure 19-mm nozzle, 310 kpa water pressure 0.65 min/m 2 7 December

60 7 December

61 Temperature rise 140 C C for the five thermocouples Temperature rise 180 C C for any thermocouple Heat Flux No openings that pass water to the unexposed side during hose stream 7 December

62 Addressed in Appendix A.II Test in A-60 A fixture Test the largest and smallest, each type and each orientation, or your limited to what you tested Damper installed with coaming or spigot Combined length of damper and coaming 900 mm Damper on exposed face with operative controls 450 mm on each side Damper at least 225 mm from core Open for start of test 7 December

63 Instrumentation Four thermocouples total two at each location On insulation 25 mm from unexposed surface On surface of coaming 25 mm from where the coaming emerges 7 December

64 Criteria Integrity requirements (mainly) 6 mm and 25 mm gaps Indication of degree of closure No flaming through the damper Temperature requirements left to the Administration 7 December

65 Addressed in Appendix A.III Test in A-60 A fixture Test the largest and smallest, each type and each orientation, or your limited to what you tested Project 500 mm into the furnace and 500 mm out of the furnace Exposed end is blanked off 7 December

66 Instrumentation Two at each location On surface of pipe 25 mm from where it emerges from the seal On pipe penetration 25 mm from unexposed face of insulation On surface of any insulation or filling material used between the pipe and any coaming or spigot Additional may be required depending on the complexity 7 December

67 Criteria Integrity requirements (mainly) 6 mm and 25 mm gaps No flaming through the penetration Maximum temperature rise 180 C C if required by the Administration Average temperature rise is not relevant Similar to F and T ratings 7 December

68 Addressed in Appendix A.IV Test in A-60 A fixture Test the largest and smallest, each type and each orientation, or your limited to what you tested Cables project 500 mm into the furnace and 500 mm out of the furnace Test with range of types and sizes No more than 40% of inside cross sectional area occupied by cables 7 December

69 Instrumentation Two positions on the outer perimeter of frame, box or comaing 25 mm from unexposed surface of the division Two positions on the face of the sealant or material, 25 mm from a cable On surface of each type of cable, 25 mm from face of sealant or material Additional may be required depending on the complexity 7 December

70 Criteria Integrity requirements (mainly) 6 mm and 25 mm gaps No flaming through the penetration Maximum temperature rise 180 C C when required by the Administration Average temperature rise is not relevant Similar to F and T ratings 7 December

71 Resolution A.754(18) is incorporated Rearranged Provides Clarification Aluminum decks with insulation below results apply only to decks with bare tops. Aluminum decks to have a covering shall be tested with the covering Doors bolted into fixture test Administration may also accept welded into fixture Doors mounted with 3-sided 3 frame mount with 12 mm to 25 mm gap at the bottom Lift landing doors exposed from corridor side 7 December

72 Adds low flame-spread characteristics and references Part 5 Furnace thermocouple change Now requires the plate thermometers 7 December

73 7 December

74 7 December

75 7 December

76 7 December

77 7 December

78 Clarification and addition of thermocouples added to B class doors Do not place thermocouples on perforated area of grille or 100 mm zone around it. Do not place thermocouples over the face of ventilation grilles Doors with top panels heights of top panel 225 mm thermocouples shall be installed on the top panel and on the joints and/or joining profile 125 mm above top of door. How many? 7 December

79 Adds a 12 mm gap gauge to integrity tools Used to evaluate gap under doors with 3 sided frames no change in gap shall not increase by more than 12 mm Clarification for intumescent seals Gap gauge test performed as if no intumescent is present Adds termination of test section Safety of personnel and equipment Attainment of Criteria Request of Sponsor 7 December

80 Dampers Clarify dimensions Minimum 250 mm from structural core to centerline of damper Minimum 500 mm of coaming on unexposed side Minimum 450 mm of insulation on coaming on unexposed side Pipe and duct penetrations A-0 0 penetrations must be tested Recommends testing A-0 A 0 penetrations in A-0 A 0 fixtures. If tested in A-60, A no insulation within 200 mm 7 December

81 Cable transit penetrations A-0 0 penetrations must be tested Recommends testing A-0 A 0 penetrations in A-0 A 0 fixtures. If tested in A-60, A no insulation within 200 mm Test conducted for maximum and minimum fill For the deck orientation, when transit is fitted on exposed side, either side is approved. When transit is fitted to unexposed side, the approval is limited for that application. For Bulkhead, when transit is fitted on either side, both sides are required to be tested 7 December

82 Where a control system of fire doors is required to be able to operate in case of fire, the system shall comply with this part. New New part? Not really Existed in Resolution MSC.45(65) 7 December

83 Test Procedures for Fire-Resisting Divisions of High- Speed Craft Fire-resisting resisting (FR) properties ability to insulate/protect an area from influence of fire in an adjoining area Moderate fire hazard requires Fire-Resisting Division 30 Major fire hazard requires Fire-Resisting Division 60 7 December

84 Testing is generally in accordance with A.754(18) 30-min duration for FR30 60-min duration for FR60 Criteria same as A.754(18) Insulation Integrity 7 December

85 Three ways to test fire-resisting resisting division Non-load bearing FR division Follow B class requirements Load-bearing FR division having structural core presupposed in A.754(18) for A class division Follow A class requirements Other load-bearing FR division Follow B class requirements Tested with prescribed static load 7 kn/m of width bulkheads 3.5 kn/m 2 of area for decks 7 December

86 7 December

87 Minor clarification additions on loading relative to fixturing and what is to be included in final report (more detail) 7 December

88 Where a control system of fire doors is required to be able to operate in case of fire, the system shall comply with this part. Test Test a prototype on a A class fixture No openings in fixture Door is a model with weight of heaviest door to be actuated Sliding doors use original tracks and rollers 7 December

89 7 December

90 Furnace Control Heat to 200 C C within 5 min Hold at 200 C C for first 60-min period Operate the door every 5 min for first 60 min Increase the furnace temperature following the standard curve starting at 200 C C and going to 945 C Automatic switchover of control at an average furnace temperature of 300 C, keep door closed for remainder of test. 7 December

91 7 December

92 Added details for reporting requirements But don t t forget furnace control is with the plate thermometer since Part 3 is referenced 7 December

93 Barry Badders (210) December 2011

IMO COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE

IMO COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE INTERNATIONAL MARITIME ORGANIZATION E IMO SUB-COMMITTEE ON FIRE PROTECTION 50th session Agenda item 10 FP 50/10/1 25 October 2005 Original: ENGLISH COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE

More information

C-01 FIRE DECKS AND BULKHEADS

C-01 FIRE DECKS AND BULKHEADS Guideline No.: C-01(201510) C-01 FIRE DECKS AND BULKHEADS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process 2010 IMO FTP Code Revisions Parts 2, 5, 7, 8, 9 & 10 Presented by: Juan Manuel Flores, P.E. Date:

More information

Global Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd

Global Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd Global Requirements for the Fire Protection of Ships Dr Janet Murrell Warrington Certification Ltd Arch Timber 3 rd Castleford June 2011 International Maritime Organisation (IMO) International Maritime

More information

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES INTERNATIONAL MARITIME ORGANIZATION E IMO SUB-COMMITTEE ON FIRE PROTECTION 46th session Agenda item 5 FP 46/5 30 November 2001 Original: ENGLISH UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11035-03-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 25.10.2017 to 24.10.2022 Holder of certificate: DMT

More information

Guideline No.: C-02(201510) C-02 FIRE DOORS. Issued date: October 20,2015. China Classification Society

Guideline No.: C-02(201510) C-02 FIRE DOORS. Issued date: October 20,2015. China Classification Society Guideline No.: C-02(201510) C-02 FIRE DOORS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions... Contents Page No Page 1 of 14... 1 1 Introduction... 3 2 Specimen verification... 3 3 Description of supporting constructions... 3 4 Description of specimen... 3 4.1 Air transfer grille blocks... 3 5 Test

More information

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES SUPPLEMENT 3 Fire Tests for Life Safety Code Users Marcelo M. Hirschler Editor s Note: This supplement is written to assist the reader in determining the applicability of fire test standards, especially

More information

Test Report: ICL/H18/9039 Rev 1

Test Report: ICL/H18/9039 Rev 1 Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692 5155 Email: firetesting@intersciencecomms.co.uk

More information

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] 4.3.11.5.5 Materials within a raised floor plenum exposed to the airflow shall be (a) noncombustible or (b) exhibit a maximum flame spread index of 25

More information

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Page 1 of 27 Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Test Sponsor Saveguard (UK) Limited Warrington Fire Research Centre Ltd.,

More information

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation Speaker: Dr. L. K. Sze, Lipmann Technical Director of Date: 23 January, 2018 Disclaimer:

More information

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly ASTM E119-98: Standard Test Methods for Fire Tests of Building Construction and Materials* *Research-scale horizontal

More information

Public Comment No. 1-NFPA [ Section No ]

Public Comment No. 1-NFPA [ Section No ] Page 1 of 7 Public Comment No. 1-NFPA 556-2014 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA, 19428-2959. ASTM D2859, Standard

More information

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves. Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves Report No: 172158 Prepared for: Lindab Ventilation AB SE 26982 Båstad Järnvägsgatan

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13 Test Report No. AJHG1501000530FB Date: FEB.17, 2015 Page 1 of 13 ZHEJIANG TERASUN AIR DUCT CO., LTD MAREN VILLAGE, CHONGREN INDUSTRIAL ZONE, CHONGREN TOWN, SHENGZHOU CITY, ZHEJIANG PROVINCE, CHINA The

More information

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 IMO E Ref.: T4/4.01 MSC.1/Circ.1272 4 June 2008 GUIDELINES FOR THE APPROVAL OF FIXED WATER-BASED

More information

Applicable international instruments for construction, performance and testing requirements 1

Applicable international instruments for construction, performance and testing requirements 1 Product Coverage For Mutual Recognition Life saving appliances Lifebuoy self-activating smoke signals (pyrotechnics) Rocket parachute flares (pyrotechnics) Hand flares (pyrotechnics) Buoyant smoke signals

More information

Fire Test Methods ASTM NFPA UL ISO IEC

Fire Test Methods ASTM NFPA UL ISO IEC Fire Test Methods ASTM NFPA UL ISO IEC D2859 (Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials) E84 (Standard Test Method for Surface Burning Characteristics

More information

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance

More information

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] 1.3 Application. 1.3.1 This standard shall apply to all systems for the movement of environmental air in structures that serve the following, except

More information

#5 Proposed Revisions to the Acceptance Criteria for Metallic HVAC Duct Enclosure Assemblies, Subject AC179-1011-R1 (RB/MB) John D. Nicholas Representing Background Relevant to AC179 18 Years in the Building

More information

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO MSC 84/24/Add.2 RESOLUTION MSC.265(84) OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization

More information

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) GENERAL Fibershield EW is a NEW and INNOVATIVE low radiation attenuation and partially insulating automatic fire curtain. It was developed to meet

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 17819 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 29.06.2017 to 10.08.2019 Holder of certificate: MPA

More information

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels RULES FOR CLASSIFICATION Inland navigation vessels Edition December 2015 Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels The content of this service document

More information

RESOLUTION MSC.101(73) (adopted on 5 December 2000) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES

RESOLUTION MSC.101(73) (adopted on 5 December 2000) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES RESOLUTION MSC.101(73) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International

More information

CERTIFICATE OF FIRE APPROVAL

CERTIFICATE OF FIRE APPROVAL LR427.203.2 CERTIFICATE OF FIRE APPROVAL This is to certify that The product(s) detailed below will be accepted for compliance with the applicable Lloyd s Register Rules and Regulations for use on offshore

More information

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c 1.0 INTRODUCTION This report presents the results of a fire performance evaluation in accordance with the 2011 Edition of National Fire Protection Association (NFPA) Standard 265, Standard Methods of Fire

More information

Fire resistance testing of technical cabinets in accordance with EN

Fire resistance testing of technical cabinets in accordance with EN Fire resistance testing of technical cabinets in accordance with EN - Pierre-Yves MAZILLE 0/0/07 Introduction In depth look into specification of..h) in EN - Review of standard fire resistance test methods

More information

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement First Revision No. 1-NFPA 259-2016 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM D5865, Standard Test Method

More information

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input Public Input No. 2-NFPA 259-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM D 5865, Standard Test Method

More information

Fire Collars for Floor Wastes Understanding BCA Compliance Options

Fire Collars for Floor Wastes Understanding BCA Compliance Options Fire Collars for Floor Wastes Understanding BCA Compliance Options February 2005 Introduction There has been a great deal of discussion in recent times regarding fire testing requirements for fire collars

More information

FTSG RESOLUTIONS. This document of FTSG resolutions was issued by the Company Secretary 20 July 2012.

FTSG RESOLUTIONS. This document of FTSG resolutions was issued by the Company Secretary 20 July 2012. FTSG RESOLUTIONS This document of FTSG resolutions was issued by the Company Secretary 20 July 2012. TABLE OF CONTENTS No. 1 Moisture Content... 3 No. 2 Moisture Content Limits... 4 No. 3 Moisture Content...

More information

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009 IMO FP 53 Report Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee 16 th March, 2009 Hot topics: Consideration continues on inerting to prevent fire and explosion on small

More information

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 0171-735 7611 Fax: 0171-587 3210 Telex: 23588 IMOLDN G Ref. T4/4.01 IMO E MSC/Circ.911 4 June 1999 INTERPRETATIONS OF FIRE

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Merchant Vessels

More information

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings

More information

PERFORMANCE OF CLT ASSEMBLIES IN FIRE

PERFORMANCE OF CLT ASSEMBLIES IN FIRE PERFORMANCE OF CLT ASSEMBLIES IN FIRE Noureddine Benichou, Ph.D., National Research Council Canada Christian Dagenais, Eng., M.Sc., FPInnovations May 28, 2015 Background Mass timber, such as CLT, are generally

More information

CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011

CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011 CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011 This Guide was drawn up by a CEPE Committee based on the best knowledge currently available. The

More information

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415 ASSESSMENT REVIEW Review of Assessment Report WFRA C91415 Fire resistance performance of steel electrical wall boxes mounted in plasterboard partitions with modified mounting arrangements, box design and

More information

Test Report: ICL/CR15/11/087

Test Report: ICL/CR15/11/087 Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692 5155 Email: firetesting@intersciencecomms.co.uk

More information

FIRE TESTING SERVICES FIRE TESTING SER

FIRE TESTING SERVICES FIRE TESTING SER FIRE TESTING SERVICES At TUV SUD PSB, we have a fire testing laboratory that was established since the late 70 s. We provide fire tests and inspection services for various industries, both locally and

More information

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 5 Tech Notes TESTING PROTOCOL Fire Retardant Gel Coats Issue Date: 4/22/2010 Document ID: TN-TS-05A 2010 Interplastic Corporation Testing Protocol

More information

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS INTERNATIONAL MARITIME ORGANIZATION E IMO ASSEMBLY 23rd session Agenda item 17 A 23/Res.951 25 February 2004 Original: ENGLISH Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED

More information

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO Test report NanoPhos coating system EPR and EEN Name of client: NanoPhos SA File no.: PFB10173A Date: 2015-10-14 Pages: 5 Encl.: 1 Ref: BP / KTO Danish Institute of Fire and Security Technology Jernholmen

More information

CERTIFICATE OF FIRE APPROVAL

CERTIFICATE OF FIRE APPROVAL LR2009.030. CERTIFICATE OF FIRE APPROVAL This is to certify that The product(s) detailed below will be accepted for compliance with the applicable Lloyd s Register Rules and Regulations for use on offshore

More information

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL 14SH200001022 STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL DUCTLINER GS - VENTILATION, SMOKE OUTLET AND KITCHEN EXTRACT DUCT SYSTEMS Tested under BS 476: Part 24: 1987 Fire tests building materials

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Schedule of Accreditation 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK PO Box 26385 Corner of 46th and 47th Streets Jebel Ali Industrial Area 1 Dubai United Arab Emirates Contact: Mr

More information

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services INFRASTRUCTURE TECHNOLOGIES Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services Test Report Author: Peter Gordon Report number: FSP 1960 Date: 5 February 2019 Client:

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

FACADES AND FIRE The Essential Elements

FACADES AND FIRE The Essential Elements FACADES AND FIRE The Essential Elements Andy Dean BSc (Hons), MCIOB, FSFE Head of Façade Engineering WSP Middle East Manama, Bahrain, Jun 2014 Reaction to fire versus fire resistance LEARNING OBJECTIVES

More information

RULES FOR CLASSIFICATION OF MOBILE OFFSHORE UNITS

RULES FOR CLASSIFICATION OF MOBILE OFFSHORE UNITS CHINA CLASSIFICATION SOCIETY RULES FOR CLASSIFICATION OF MOBILE OFFSHORE UNITS PART SEVEN FIRE AND EXPLOSION SAFETY PART SEVEN FIRE AND EXPLOSION SAFETY CONTENTS CONTENTS CHAPTER 1 GENERAL... 7-1 Section

More information

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 Telex: 23588 IMOLDN G IMO E Ref. T4/4.01 MSC/Circ.1007 26 June 2001 GUIDELINES FOR THE

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply

More information

January 1, 2014 Mandatory Effective Date

January 1, 2014 Mandatory Effective Date 2013 Kentucky Building Code Highlights Winnie Blythe, Technical Advisor Dept. of Housing, Buildings, and Construction winnie.blythe@ky.gov www.dhbc.ky.gov 502-573-0373 January 1, 2014 Mandatory Effective

More information

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor: IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2 Smoke & Toxicity Test WF Report Number: 166040 Date: 13 th August 2007 Test Sponsor: Fiba Tech Industries Ltd. 0249 Page 2 of 13 Bodycote warringtonfire

More information

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 12 December 1996 Ref. T4/4.01 GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 1 The Maritime Safety

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: Indicative fire test WF Report

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply with this chapter and the International

More information

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES E 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: +44 (0)20 7735 7611 Fax: +44 (0)20 7587 3210 7 December 2018 REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR

More information

Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches

Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches 2014-09-19 SP Method 4912 Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches 2014-09-19 page 2 (17) Copyright This test method

More information

RESOLUTION MSC.44(65) (adopted on 11 May 1995) STANDARDS FOR FIXED SPRINKLER SYSTEMS FOR HIGH SPEED CRAFT

RESOLUTION MSC.44(65) (adopted on 11 May 1995) STANDARDS FOR FIXED SPRINKLER SYSTEMS FOR HIGH SPEED CRAFT MSC 65/25/Add.2 RESOLUTION MSC.44(65) THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning the functions of the Committee, NOTING

More information

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and rectangular type with one, two, three or four way patterns.

More information

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877. Return address: P.O. box 337, 7500 AH Enschede, TNO Centre for Textile Research Ariënsplein 3 7511 JX ENSCHEDE Forbo Flooring Attn. Mr. A. Tijhof Postbus 13 1560 AA Krommenie Report Sponsor : Contractor,

More information

SECTION DUCTWORK

SECTION DUCTWORK PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on

More information

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document 1 of 19 10/21/2015 1:20 PM Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three ASME International, Two

More information

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION) GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION) February, 2017 Contents Clauses Page 1. Basic Concepts 1 2. Design Considerations 1 3. Car Parks Ventilation 2 4. Kitchen

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015 Peter McDonnell, PE, LEED AP BD+C McClure Engineering UL DAMPER TEST STANDARDS UL 555 - FIRE DAMPERS UL555S SMOKE DAMPERS UL555C CEILING

More information

HORIZONTAL COMPLEMENT TO THE MANDATES TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR

HORIZONTAL COMPLEMENT TO THE MANDATES TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR EUROPEAN COMMISSION DIRECTORATE-GENERAL III INDUSTRY Industrial affairs II: Capital goods industries Construction M 117 HORIZONTAL COMPLEMENT TO THE MANDATES TO CEN/CENELEC CONCERNING THE EXECUTION OF

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 3008-2 Second edition 2017-05 Fire-resistance tests Part 2: Lift landing door assemblies Essais de résistance au feu Partie 2: Assemblage de porte palière d ascenseur Reference

More information

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by Norman Alvares & Harry Hasegawa First Paragraph of E-691 Tests performed on presumably identical materials in presumably

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information

First Revision No. 6-NFPA [ Section No. 2.2 ]

First Revision No. 6-NFPA [ Section No. 2.2 ] Page 1 of 18 First Revision No. 6-NFPA 555-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 12, Standard on Carbon

More information

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur. First Revision No. 1-NFPA 501-2015 [ Section No. 5.3.1.3 ] 5.3.1.3 The following conditions shall be met when an interior finish material is tested using the test protocol of NFPA 286, Standard Methods

More information

Annex to the Accreditation Certificate PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate PL-18354-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 11.12.2018 to 21.12.2022 Date of issue: 11.12.2018 Holder

More information

Report on Public Input June 2014 NFPA 101

Report on Public Input June 2014 NFPA 101 101 PI# 115 SAF-FUR (10.2.1.2) 10.2.1.2 Materials applied directly to the surface of walls and ceilings in a total thickness of less than 1 / 28 in. (0.9 mm) shall not be considered interior finish and

More information

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS Report number FSZ 1572 CSIRO job number SV3559 Date of issue 22 FEBRUARY 2013 Client BREEZWAY AUSTRALIA PTY LTD Commercial-in-confidence Copyright CSIRO 2013 Copying

More information

RESOLUTION MSC.61(67) (adopted on 5 December 1996) ADOPTION OF THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES

RESOLUTION MSC.61(67) (adopted on 5 December 1996) ADOPTION OF THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES RESOLUTION MSC.61(67) TIlE MARITIME SAFETY COMMITTEE. RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning the functions of the Committee. RECOGNIZING the need

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

MOBILE OFFSHORE DRILLING UNITS 2012

MOBILE OFFSHORE DRILLING UNITS 2012 Part 5: Fire and Safety Measures and Features RULES FOR BUILDING AND CLASSING MOBILE OFFSHORE DRILLING UNITS 2012 PART 5 FIRE AND SAFETY MEASURES AND FEATURES American Bureau of Shipping Incorporated by

More information

NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX

NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX 1. Call to Order. The meeting of the Technical Committee on Fire Tests

More information

This standard shall prescribe provisions based on minimum requirements for safety to life and property.

This standard shall prescribe provisions based on minimum requirements for safety to life and property. NFPA STANDARDS DEVELOPMENT SITE FIRST DRAFT REPORT Closing Date: February 22, 2013 NOTE: All Public Comment must be received by 5:00 pm EST/EDST on the published Closing Date. NFPA 90B, Standard for the

More information

Star Princess Safety Centre. Annex A

Star Princess Safety Centre. Annex A Star Princess Safety Centre Annex A Star Princess Safety Centre Star Princess has a highly automated system for managing ship emergencies. Sensors within the ship monitor the operation of key systems including

More information

OFFICINE MINUTE VILLORBA - TREVISO

OFFICINE MINUTE VILLORBA - TREVISO OFFICINE MINUTE VILLORBA - TREVISO A15 A23 A25 A22 A23 A12 A14 A10 A21 A4 A3 A21 A2 A5 A21 A7 A21 A16 A17 A18 A21 A8 A1 A13 A14 A9 A19 A11 A20 A24 A1 - Linear gas burner A2 - Air mixing area A3 - Hot air

More information

DUCT SYSTEMS CHAPTER 6

DUCT SYSTEMS CHAPTER 6 SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter except as otherwise

More information

IMO Resolution MSC 61(67): Annex 1: Part 2

IMO Resolution MSC 61(67): Annex 1: Part 2 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IMO Resolution MSC 61(67): Annex 1: Part

More information

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters 237300 AIR HANDLING PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230530 Clean Steam Generation B. Section 230900 Building Automation and Control System Guidelines C. Section 234100 Air Cleaning Devices

More information

Analysis Report

Analysis Report Prestige Carpets bvba Dhr. Dirk Santens Klein Frankrijk 38 9600 RONSE Your notice of Your reference Date 19-06-2013 24-07-2013 Required tests : Identification number T1309624 Information given by the client

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection 6 Inside buildings there are two types of fire protection systems: Active Fire Protection and Passive Fire Protection. Both systems should actively work together in the event of a fire. 6.1.1 The four

More information

Intumescent Fire Dampers

Intumescent Fire Dampers Ph 1300 858 010 Intumescent Fire Dampers Fire resistant walls and floors in a building play an important part in containing the spread of fire and smoke. However, a building also needs to be well ventilated

More information

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited BS 476: Part 3: 2004 External Fire Exposure Roof Test WF Report Number: 153420 Date: 28 th April 2006 Test Sponsor: Tapco Europe Limited 0249 Page 2 of 9 Warringtonfire Test Report No 153420 BS 476: Part

More information

Report on First Revision June 2014 NFPA 101

Report on First Revision June 2014 NFPA 101 101 FR500 SAF-FUR (10.2.1.2 and 10.2.1.3) Recommendation: 10.2.1.2 The provisions of Section 10.2.1.1 shall not apply to mmaterials having a total thickness of less than 1/28 in (0.9 mm) that are applied

More information

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS Report number FSP 1290A CSIRO job number LP46ASP3085 Date of issue 30 NOVEMBER 2007 Client EFFICIENCY MATRIX PTY LTD and YOUNGEN

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION FC 1801 GENERAL 1801.1 Scope. This chapter shall govern the design, installation, operation and maintenance of semiconductor fabrication facilities

More information