The Association for Specialist Fire Protection

Size: px
Start display at page:

Download "The Association for Specialist Fire Protection"

Transcription

1 The Association for Specialist Fire Protection An Association for Specialist Fire Protection CPD Event Understanding the Disciplines of Passive Fire Protection 17 th June 2015 In association with

2 The Association for Specialist Fire Protection Understanding your legal responsibilities Wilf Butcher, CEO for the Association for Specialist Fire Protection Why is 3rd Party Certification essential? Ian Woodhouse, Director of Certification, IFC Certification Ltd Compartmentation, fire stopping installation and maintenance Oliver Shaw, Sales Director, FSi Refreshment Break and networking

3 The Association for Specialist Fire Protection The role of fire doors, and glazing Peter Barker, Senior Consultant Fire, BM TRADA Ducts and Dampers, fire safety inspection Michael Hunter, Technical Manager, Saint-Gobain Isover Structural fire protection, getting the specification right Roger Williams, Global Market Director, Sherwin-Williams Protective & Marine Coatings Fire Risk Assessment, ensuring that it is suitable and sufficient Niall Rowan, Technical Officer of Association for Specialist Fire Protection Addressing future training in Passive Fire Protection Wilf Butcher, CEO, Association for Specialist Fire Protection Q&A

4 The Association for Specialist Fire Protection Fire and Your Legal Liability Wilf Butcher, CEO Association for Specialist Fire Protection

5 The Association for Specialist Fire Protection

6 The Reality of Fire 2000 years ago life was simple King Herod (74BC-4AD) introduced a law which stated that: Should a man construct a building which falls down and kills another then this man should be slain.

7 The Reality of Fire Life is a little more complicated today! So just how important are passive fire protection measures in today s building design! Other than fire fighters few of us have had to face the reality of fire and smoke spread!

8 The Reality of Fire So just how important are passive fire protection measures in today s building design!

9 The Reality of Fire The answer of course is quite clear, it s essential!

10 The Reality of Fire The answer starts with the specification

11 The Reality of Fire Fire damaged buildings can always be rebuilt Their priceless content however will be lost forever Statistically 40% of businesses will be out of business within months following a major fire

12 The Reality of Fire Is designing for or building in an appropriate fire solution simply a matter of determining what is suitable and sufficient?

13 The Reality of Fire Is designing for or building in an appropriate fire solution simply a matter of determining what is suitable and sufficient? Or is the route to construction a little more complex!

14 The Reality of Fire Is designing for or building in an appropriate fire solution simply a matter of determining what is suitable and sufficient? Or is the route to construction a little more complex!

15 Statutory guidance documents Statutory guidance documents England & Wales Approved Document B 2006 Scotland Technical Handbook B 2010 Northern Ireland Technical Booklet E 2005 Republic of Ireland Technical Guidance Document B 2006 Other codes of practice BS 9999: Fire safety in the design management and use of buildings BS 9991: for residential buildings BS 7974: Application of fire safety engineering principles to the design of buildings Department of education BB 100 Design for fire safety in schools Health Technical Memorandum 05 01, 05 02A, 05 02B, 05 03

16 The Building Regulations Approved Document B: 2006 Lists the requirements for fire resistance of compartment walls and floors, including any steel passing through the compartment wall/floor. Section 10.2 If a fire separating element is to be effective, every joint or imperfection of fit, or opening to allow services to pass through the element, should be adequately protected by sealing or fire-stopping so that the fire resistance of the element is not impaired Section In addition to other requirements for fire-stopping, all joints between fire separating elements should be fire stopped, and all openings for pipes,ducts, conduits or cables to pass through any part of a fire separating element should be Kept as few in number as possible Kept as small as possible Fire stopped [which in case of a pipe or duct, should allow thermal movement]

17 The Building Regulations Technical Guidance Document B: 2006 This can be the reality!

18 The Building Regulations The England and Wales Building Regulations also state: 3 rd Party Installation Certification ADB provide a means of ensuring that installations have been conducted by knowledgeable contractors to appropriate standards, thereby increasing reliability of the anticipated performance in fire

19 The Building Regulations 3 rd Party Certification is not mandatory!

20 The Building Regulations Regulation 7 building work shall be carried out with adequate and proper materials which are appropriate for the circumstances in which they are used But is it all not just common sense?

21 The Building Regulations I think I have made my point!

22 The Building Regulations Building Regulation 38 Within the Building Regulations there is an expectation that the duties of Building Regulation 38 (previously known as Regulation 16b) will be reliably carried out and the building user/owner will be fully informed of the fire protection provisions in the building he now occupies Regulation 38 requires that, where building work involves the erection or extension of a relevant building, fire safety information shall be given to the responsible person at the completion of the project or when the building or extension is first occupied Appendix G

23 Regulatory Reform (Fire Safety) Order 2005 Regulatory Reform (Fire Safety) Order 2005

24 Regulatory Reform (Fire Safety) Order 2005 Regulatory Reform (Fire Safety) Order 2005

25 Regulatory Reform (Fire Safety) Order 2005 Regulatory Reform (Fire Safety) Order 2005

26 Regulatory Reform (Fire Safety) Order 2005 Regulatory Reform (Fire Safety) Order 2005

27 The Building Regulations RRO(FS)O Article 17 Maintenance 83. The responsible person must ensure, where necessary in order to safeguard the safety of relevant persons, that the fire precautions are maintained in good working order (see also article 38, about protection of fire-fighters). This includes any facilities which have been provided under Building Regulations, the Housing Act 2004 or other legislation such as local Acts; and including any enactment repealed or revoked by the Order. Risk assessments, as required by article 9, should include references to maintenance.

28 The responsibility is yours FIRE AND YOUR LEGAL LIABILITY If you are involved in provision of fire protection, at any level, then you share liability for its usefulness and its operation when it s needed in fire, and that liability will still be there in the event of a court case.

29 The responsibility is yours FIRE AND YOUR LEGAL LIABILITY If it is your responsibility to specify the materials and/or appoint the installation contractor, it is also your responsibility to ensure that they can prove competency for the fire protection materials used, or the works to be carried out. It s no longer simply a duty of care or voluntary it s a legal obligation. Are you competent?

30 The responsibility is yours FIRE AND YOUR LEGAL LIABILITY If it is your responsibility to manage or install passive fire protection products, materials or systems, it is also your responsibility to ensure that they are fit for purpose i.e. that the manufacturer s fire test and certification evidence fully covers the intended use.

31 The responsibility is yours FIRE AND YOUR LEGAL LIABILITY It is also your responsibility to ensure that the installer can demonstrate appropriate competency in the installation of the passive fire protection products, materials and systems used. It s no longer simply a duty of care or voluntary it s a legal obligation

32 The responsibility is yours FIRE AND YOUR LEGAL LIABILITY It is your responsibility to ensure that any installation of, or repair to, passive fire protection is undertaken by those with sufficient competency

33 The responsibility is yours FIRE AND YOUR LEGAL LIABILITY It is your responsibility to ensure that any installation of, or repair to, passive fire protection is undertaken by those with sufficient competency

34 The responsibility is yours Monitoring FIRE AND YOUR LEGAL LIABILITY The frequency of monitoring activity will be dictated by the building s risk profile. Buildings with hazardous contents, high occupancy levels or high rates of change are examples of a higher risk category. The period between monitoring activities should not, of course, be allowed to exceed any Statutory or Health and Safety Executive guidance minimum. It is important to ensure that all activities within the building that might affect the PFP are monitored and responded to where necessary.

35 The responsibility is yours Which is why it is essential you ensure that the people or company you employ to carry out the work can PROVE that they are competent

36 The responsibility is yours Because you should not assume that competency in one discipline will automatically be reflected in another

37 Fire is a holistic issue Make a start with the two ASFP documents Ensuring Best Practice for Passive Fire Protection in Buildings ASFP Guide to Inspecting Passive Fire Protection for Fire Risk Assessors Find out more on at the ASFP Zone (Stand D179)

38 A building is for life! The simple fact is that passive fire protection works!

39 A building is for life! The simple fact is that passive fire protection works!

40 A building is for life! The simple fact is that passive fire protection works!

41 A concluding thought!

42 To Sum Up What conclusions can we draw from this short presentation? When it comes to fire protection, there s nothing wrong with thinking outside of the box. Provided you understand the consequences of getting it wrong! Questions

The Association for Specialist Fire Protection. Guidance in Passive Fire Protection

The Association for Specialist Fire Protection. Guidance in Passive Fire Protection The Association for Specialist Fire Protection Guidance in Passive Fire Protection Wilf Butcher CEO Association for Specialist Fire Protection The ASFP - A brief background history When Originally known

More information

The Association for Specialist Fire Protection

The Association for Specialist Fire Protection The Association for Specialist Fire Protection Passive Fire Protection Understanding the Risks! Wilf Butcher Chief Executive Officer Association for Specialist Fire Protection How does the dictionary define

More information

Managing Fire Safety in Occupied Buildings FM Ireland Fire Safety Theatre

Managing Fire Safety in Occupied Buildings FM Ireland Fire Safety Theatre FM Ireland Fire Safety Theatre Welcome David O Reilly FIFireE Association for Specialist Fire Protection in Ireland Institution of Fire Engineers Republic of Ireland Branch President International General

More information

The Association for Specialist Fire Protection. Understanding Best Practice in passive fire protection

The Association for Specialist Fire Protection. Understanding Best Practice in passive fire protection The Association for Specialist Fire Protection Understanding Best Practice in passive fire protection Niall Rowan, Technical Officer Association for Specialist Fire Protection The Association for Specialist

More information

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection Passive Fire Protection Guidance for the Fire Risk Assessor Niall Rowan Technical Officer Association for Specialist Fire Protection ASFP has just completed a guide on what to look for when undertaking

More information

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection Passive Fire Protection Guidance for the Fire Risk Assessor Niall Rowan Technical Officer Association for Specialist Fire Protection ASFP has just completed a guide on what to look for when undertaking

More information

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

FIRE RISK ASSESSMENT COMPETENCY COUNCIL FIRE RISK ASSESSMENT COMPETENCY COUNCIL A Guide to Choosing a Competent Fire Risk Assessor Version 2 Published 29/4/14 The Fire Risk Assessment Competency Council is a workstream consisting of the major

More information

Understanding Passive Fire Protection

Understanding Passive Fire Protection ASFP Response to Hackitt Report/Scottish Regulatory Review What is Passive Fire Protection and why is it important? Niall Rowan Chief Executive Officer Association for Specialist Fire Protection Contents

More information

Shared Services Partnership

Shared Services Partnership Shared Services Partnership Facilities Services Fire Compartmentation in Healthcare Prince Philip Hospital - Thursday 7 th November 2013 Ysbyty Glan Clwyd - Tuesday 19 th November 2013 Royal Glamorgan

More information

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited June 2017 (Updated 18 January 2018) Fire Safety Policy Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited Trusted provider of quality homes, excellent landlord and support services,

More information

PASSIVE FIRE PROTECTION GETTING IT RIGHT

PASSIVE FIRE PROTECTION GETTING IT RIGHT PASSIVE FIRE PROTECTION GETTING IT RIGHT Niall Rowan Technical Officer Association for Specialist Fire Protection Contents Who is the ASFP? Passive Fire Protection What is it? How does it work? The installation

More information

PASSIVE FIRE PROTECTION GETTING IT RIGHT

PASSIVE FIRE PROTECTION GETTING IT RIGHT PASSIVE FIRE PROTECTION GETTING IT RIGHT Niall Rowan Technical Officer Association for Specialist Fire Protection Contents Who is the ASFP? Passive Fire Protection What is it? How does it work? The installation

More information

FIRE SAFETY POLICY Revised March 2013

FIRE SAFETY POLICY Revised March 2013 FIRE SAFETY POLICY Revised March 2013 CONTENTS Page No 1.0 Statement of Intent 1 2.0 Fire Safety Accountability Structure 2 3.0 Roles and Responsibilities 3 4.0 Fire Safety Management 7 5.0 Fire Risk Assessment

More information

Secretary of State determination under article 36 of the Fire Safety Order

Secretary of State determination under article 36 of the Fire Safety Order Fire and Rescue Service Circular Circular number 48/2009 Date issued 13 August 2009 This circular is For information and consideration Status This circular covers the outcome of a referral to the Secretary

More information

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

FIRE RISK ASSESSMENT COMPETENCY COUNCIL FIRE RISK ASSESSMENT COMPETENCY COUNCIL Competency Criteria for Fire Risk Assessors Version 1 Published : 21/12/11 Page 1 Foreword Fire safety legislation requires that, for most premises except private

More information

Fire prevention and protection

Fire prevention and protection Fire prevention and protection The Fire Service College With over 40 years experience, the Fire Service College is a leading organisation for fire prevention, protection and response, providing assessed,

More information

Fire risk management plan. MH/05/Revised/06/17

Fire risk management plan. MH/05/Revised/06/17 Fire risk management plan MH/05/Revised/06/17 1 1. Scope This policy applies to fire safety arrangements in all workplaces, common areas of residential premises and any other premises managed and/or owned

More information

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES MANAGING FIRE SAFETY LEARNING OUTCOMES On completion of this element, you should be able to demonstrate understanding of the content by applying what you have learnt to familiar and unfamiliar situations.

More information

Lakanal House inquest: Statement from the Fire Sector Federation

Lakanal House inquest: Statement from the Fire Sector Federation Lakanal House inquest: Statement from the Fire Sector Federation The Fire Sector Federation (FSF) wishes to express profound sadness for the tragic loss of life that occurred at Lakanal House on the 3

More information

Fire Risk Management Policy. UK September 2017

Fire Risk Management Policy. UK September 2017 UK September 2017 5 & 7 Diamond Court, Opal Drive, Eastlake Park, Fox Milne, Milton Keynes MK15 0DU, T: 01908 396250, F: 01908 396251, www.cognitaschools.co.uk Registered in England Cognita Limited No

More information

Fire Safety Policy Date: 0

Fire Safety Policy Date: 0 Fire Safety Policy Date: 0 Policy Preparation & Introduction This document format has been produced by Firesafe Solutions (UK) Ltd to aid managers, tenants and others responsible for fire safety in their

More information

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 highline WINDOW CONTROLS INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM SVCS-1 * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 CERTIFICATE OF COMPLIANCE SVCS-1 We the undersigned

More information

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition Issued in the interests of safety by The Legal Obligations of Employers to Maintain all Electrical Installations

More information

Fire prevention and protection

Fire prevention and protection Fire prevention and protection The Fire Service College With over 40 years experience, the Fire Service College is a leading organisation for fire prevention, protection and response, providing assessed,

More information

FIRE SAFETY POLICY. Approval Approved by: University Court Date: March 28 th 2017

FIRE SAFETY POLICY. Approval Approved by: University Court Date: March 28 th 2017 Date: March 2017 Page 1 of 12 FIRE SAFETY POLICY Approval Approved by: University Court Date: March 28 th 2017 Page 1 of 12 Date: March 2017 Page 2 of 12 UNIVERSITY OF ABERDEEN FIRE SAFETY POLICY Contents

More information

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES Mandatory Fire Safety Instruction UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES Principal Contractor fire safety considerations in shared occupancy project or refurbishments

More information

Fire Safety Protocol

Fire Safety Protocol CORPORATE HEALTH AND SAFETY POLICY: Part 3 Arrangements Fire Safety Protocol Document Status: [ ] Guidance for Managers [] Protocol [ ] Procedures Version 0.1/ August 2013 DRAFT EALING NCIL Table of Contents

More information

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy Holme Grange School Whole School Policy Including EYFS Fire Safety Policy This document details the school s policy on fire safety in operation at Holme Grange School. The document is split into a number

More information

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety Foreword by Communities and Local Government Ministers It is always a priority to ensure safety from the

More information

Welcome to the. Firestop Seminar. Hilti Technical and Engineering Support

Welcome to the. Firestop Seminar.  Hilti Technical and Engineering Support Welcome to the Firestop Seminar www.hilti.co.uk/technical Hilti Technical and Engineering Support 1 Agenda 1. Passive Fire Protection a) The Importance of Firestop b) What are the Regulations c) Test Criteria

More information

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group.

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group. FIRE SAFETY POLICY Approver Executive Management Team Policy Fire Safety Policy Monitored By Health, Safety and Fire Steering Group. Date last revised April 2017 Revised by James Warne Next Revision Date

More information

Dangerous Assumptions

Dangerous Assumptions Dangerous Assumptions In light of the lessons learned from the Lakanal House fire, the on-going competent inspection of passive fire protection is crucial to safeguarding those who put their trust in social

More information

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020 Policy title: Scope: Policy owner & job title: Approver: Fire Safety Policy Group-wide Dan Gray, Property Director Aspire Housing Board Date: November 2017 Review Due Date: November 2020 POLICY SUMMARY

More information

CD/12 Form (Landlord Oil Installation Check)

CD/12 Form (Landlord Oil Installation Check) CD/12 Form (Landlord Oil Installation Check) Diagram 47a 1 2 3 4 5 6 7 8 9 10 2010 Edition Section 7 Page 9 7.5 CD/14 (Warning & Advice Notice) 7.5.1 General This form can be used to formally notify oil

More information

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames Section 2 - Applications - General Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames Section 2B - FD30 Strebord 35+, 38+, 44, Superpan & Strebord 54 with Steel Frames Section 2C

More information

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES This is a new procedural document, please read in full. Did you print this document yourself? The Trust discourages the retention of hard

More information

FIRE SAFETY POLICY June 2014

FIRE SAFETY POLICY June 2014 FIRE SAFETY POLICY June 2014 Policy Title Fire Safety Policy Reference Number Corpo11/002 Implementation Date June 2014 1 st Review Review Date June 2017 Responsible Officer Director of Performance and

More information

Inspection & maintenance of fire doors a credible action plan. Presented by Clive Reilly Checkmate Fire Solutions Ltd

Inspection & maintenance of fire doors a credible action plan. Presented by Clive Reilly Checkmate Fire Solutions Ltd Inspection & maintenance of fire doors a credible action plan Presented by Clive Reilly Checkmate Fire Solutions Ltd Fire Doors The installation of a fire door is a complex procedure requiring a detailed

More information

Proposed Social Housing (Automatic Fire Suppression Systems) (Scotland) Bill Shelter Scotland consultation response

Proposed Social Housing (Automatic Fire Suppression Systems) (Scotland) Bill Shelter Scotland consultation response Proposed Social Housing (Automatic Fire Suppression Systems) (Scotland) Bill Shelter Scotland consultation response April 2018 Until there s a home for everyone. shelter.org.uk SUMMARY Shelter Scotland

More information

Fire safety policy. Contents. This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years.

Fire safety policy. Contents. This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years. Fire safety policy This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years. Contents 1. Policy principles 2 2. Statutory and Regulatory Framework

More information

Fire Safety Policy. Document Author: Director of Estates, Fleet & Facilities Management

Fire Safety Policy. Document Author: Director of Estates, Fleet & Facilities Management Fire Safety Policy Document Author: Director of Estates, Fleet & Facilities Management Date Approved: January 2018 Document Reference Fire Safety Policy January 2020 Version V: 2.1 Responsible Committee

More information

Managing fire safety. What s the risk? Bruce Kirkham Principal Consultant Capstone Ltd

Managing fire safety. What s the risk? Bruce Kirkham Principal Consultant Capstone Ltd Managing fire safety What s the risk? Bruce Kirkham Principal Consultant Capstone Ltd Managing Fire Safety What s the risk? Bruce Kirkham PGDip, MCGI, MIFireE, MICPEM, MEPS Annual Conference February 2018

More information

Health & Safety Policy HSP 03 Fire Safety Version Status Date Title of Reviewer Purpose/Outcome

Health & Safety Policy HSP 03 Fire Safety Version Status Date Title of Reviewer Purpose/Outcome Health & Safety Policy HSP 03 Fire Safety Version Status Date Title of Reviewer Purpose/Outcome 1.0 Draft 07.03.2016 David Maine 1 st Draft for consultation/review 1.1 Approved 22.12.2016 David Maine 1

More information

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School OBJECTIVE This Fire Safety Policy is designed to help Putnoe Primary School comply with their duties under the Regulatory Reform (Fire Safety

More information

Fire Safety Policy. Contents. This policy was approved by the Trustees on 6 September 2018 and will be reviewed not later than every 5 years.

Fire Safety Policy. Contents. This policy was approved by the Trustees on 6 September 2018 and will be reviewed not later than every 5 years. Fire Safety Policy This policy was approved by the Trustees on 6 September 2018 and will be reviewed not later than every 5 years. Contents 1. Policy principles 2 2. Statutory and Regulatory Framework

More information

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO) 4 PEEL HOUSE,TAUNTON STREET,SHIPLEY,BN18 3NA TEL: 01274 595015 FAX: 01274 580804 EMAIL:sales@rosse-systems.co.uk A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO) THE PURPOSE OF THIS DOCUMENT

More information

Arbour House. Fire Policy and Procedures

Arbour House. Fire Policy and Procedures Arbour House Fire Policy and Procedures Policy Review Date: May 2017 Introduction Arbour House School endeavours to ensure that risks from fire are identified and that arrangements are in place to control

More information

Managing Fire Safety Through Construction. Reece Walker Arup Fire Engineer

Managing Fire Safety Through Construction. Reece Walker Arup Fire Engineer Managing Fire Safety Through Construction Reece Walker Arup Fire Engineer Contents When it goes wrong, what is at risk Legislation and Guidance Who s responsible Risk assessment process Project Case Study

More information

BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July Part of the BRE Trust

BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July Part of the BRE Trust BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July 2016 Part of the BRE Trust Introduction New buildings: Building Regulations 2010 Existing buildings: Regulatory Reform (Fire Safety)

More information

Fire Safety in Places of Worship An Insurers Perspective. Kevin Thomas, FCII, CFIRM Principal Risk Management Surveyor

Fire Safety in Places of Worship An Insurers Perspective. Kevin Thomas, FCII, CFIRM Principal Risk Management Surveyor Fire Safety in Places of Worship An Insurers Perspective Kevin Thomas, FCII, CFIRM Principal Risk Management Surveyor Regulatory Reform (Fire Safety) Order 2005 Replaced 100+ pieces of fire safety legislation

More information

Loss Prevention Standards

Loss Prevention Standards Introduction Fire compartmentation is an essential part of an effective fire safety design of a building. The primary objective of fire compartmentation or passive fire protection is to prevent a building

More information

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide BWF-Certifire Fire Doors and Doorsets Best Practice Guide 1 BWF-Certifire BWF-Certifire: The leading authority on fire door safety A fire door is a vital safety device engineered to save lives and property.

More information

FIRE SAFETY GUIDELINES for SCOUTING IRELAND Scout Dens and Meeting Places

FIRE SAFETY GUIDELINES for SCOUTING IRELAND Scout Dens and Meeting Places FIRE SAFETY GUIDELINES for SCOUTING IRELAND Scout Dens and Meeting Places Prepared by Eamon O Boyle and Associates Client Scouting Ireland Date October 2018 Job Ref. No. 17103 Report Ref. No. 17103-FSG-R01

More information

Electrical Safety Policy and Management System

Electrical Safety Policy and Management System TITLE: PAGE: 1 OF 14 Housing Solutions Limited Electrical Safety Policy and Management System Page 1 of 15 TITLE: PAGE: 2 OF 14 FOREWORD This document details the system for the management of electrical

More information

16 Steps to fire safety. Promoting good practice on structural timber construction sites Version 4.1 May 2017

16 Steps to fire safety. Promoting good practice on structural timber construction sites Version 4.1 May 2017 16 Steps to fire safety Promoting good practice on structural timber construction sites Version 4.1 May 2017 Section 1 - Introduction and application scope This document provides summary guidance for the

More information

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be EMLC Academy Trust Fire Safety Policy 2017/19 Every child deserves to be the best they can be 1 Scope: EMLC Academy Trust & Academies within the Trust Version: 2 Filename: EMLC Academy Trust Fire Safety

More information

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions White Paper Keeping up with compliance: Escape doors standards The global leader in door opening solutions Introduction When it comes to access control, there is no greater responsibility than specifying

More information

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work 01 A sprinkler system is a pipework distribution system charged with water, with a network of heatsensitive sprinkler heads supplied via a tank/reservoir or a water main. If the temperature rises above

More information

FIRE SAFETY 2013 ANNUAL REPORT. Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett

FIRE SAFETY 2013 ANNUAL REPORT. Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett AGENDA ITEM 4.1 FIRE SAFETY 2013 ANNUAL REPORT Executive Lead: Director of Planning Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett 02920742292 SITUATION This

More information

NHSScotland Firecode. A Model Management Structure for Fire Safety Version 4. This document forms part of NHSScotland Firecode Edition No

NHSScotland Firecode. A Model Management Structure for Fire Safety Version 4. This document forms part of NHSScotland Firecode Edition No NHSScotland Firecode A Model Management Structure for Fire Safety Version 4 This document forms part of NHSScotland Firecode Edition No NHSScotland, P&EFEx, April 2004 Contents 1. About this document page

More information

Fire Risk Assessment Safety Checklist

Fire Risk Assessment Safety Checklist Fire Risk Assessment Safety Checklist This checklist has been prepared to help you comply with The Regulatory Reform Fire Safety Order 2005 What is the Regulatory Reform (Fire Safety) Order 2005? The Regulatory

More information

Fire Safety Policy 2018/19

Fire Safety Policy 2018/19 Fire Safety Policy 2018/19 Reviewed: March 2016 Next Review: March 2019 1. Policy Statement The School is committed to ensuring, so far as is reasonably practicable, the health, safety and welfare of all

More information

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems Building Standards Division Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems Crown Copyright 2015 Produced by the Buildings Standards Division February 2015 Version

More information

Grenfell Tower fire safety investigation: The fire protection measures in place on the night of the fire, and conclusions as to:

Grenfell Tower fire safety investigation: The fire protection measures in place on the night of the fire, and conclusions as to: BLAR00000017_0001 Grenfell Tower fire safety investigation: The fire protection measures in place on the night of the fire, and conclusions as to: the extent to which they failed to control the spread

More information

HVCA. Guide to Good Practice. Heating and Ventilating Contractors Association. Mothballing and Re-commissioning of Buildings SFG30

HVCA. Guide to Good Practice. Heating and Ventilating Contractors Association. Mothballing and Re-commissioning of Buildings SFG30 HVCA Heating and Ventilating Contractors Association Guide to Good Practice Mothballing and Re-commissioning of Buildings SFG30 Guide to Good Practice Mothballing and Re-commissioning of Buildings ACKNOWLEDGEMENTS

More information

Advisory Brief to Prince George City Council On the Matter of Bylaw 8727, 2013, Fire Protection and Emergency Response Bylaw

Advisory Brief to Prince George City Council On the Matter of Bylaw 8727, 2013, Fire Protection and Emergency Response Bylaw Advisory Brief to Prince George City Council On the Matter of Bylaw 8727, 2013, Fire Protection and Emergency Response Bylaw November 11, 2013 John Leech, AScT, CAE Executive Director Applied Science Technologists

More information

Management Standard: Fire Safety

Management Standard: Fire Safety OHSS: H&S Management 201 Fire Safety Management : Fire Safety 1. Legal framework This standard is produced to comply with the following legislation in respect to fire safety: 1.1. Regulatory Reform (Fire

More information

PREVENTION, PROTECTION, ROAD SAFETY

PREVENTION, PROTECTION, ROAD SAFETY PREVENTION, PROTECTION, ROAD SAFETY Competency Framework for Business Fire Safety Regulators Institution of Fire Engineers International Conference 25 th June 2014 Peter O Reilly CFOA Strategic Lead for

More information

The new fire regulations - more demands on the employer? The Regulatory Reform (Fire Safety) Order 2005

The new fire regulations - more demands on the employer? The Regulatory Reform (Fire Safety) Order 2005 The new fire regulations - more demands on the employer? The Regulatory Reform (Fire Safety) Order 2005 Adair Lewis BSc CEng FIFireE CPhys MInstP CChem MRSC Technical Manager The Fire Protection Association

More information

NHS Tayside. Fire Safety Policy

NHS Tayside. Fire Safety Policy NHS Tayside Fire Safety Policy Policy Manager Mark Anderson, Head of Property Policy Group Fire Safety Policy Review Group Policy Established Last Updated April 2014 Policy Review Period/Expiry April 2017

More information

ASFP OBTAINS FUNDING FROM CITB-CONSTRUCTIONSKILLS

ASFP OBTAINS FUNDING FROM CITB-CONSTRUCTIONSKILLS ASFP E-BULLETIN This news bulletin is brought straight to your desktop by the Association for Specialist Fire Protection (ASFP). It provides brief, easy to digest information on current built in fire protection

More information

Response to call for evidence for Independent Review of Building Regulations and Fire Safety. October 2017

Response to call for evidence for Independent Review of Building Regulations and Fire Safety. October 2017 Response to call for evidence for Independent Review of Building Regulations and Fire Safety October 2017 Tudor House Kingsway Business Park Oldfield Road Hampton Middlesex TW12 2HD Tel: 0203 166 5002

More information

Fire Door Maintenance Guide.

Fire Door Maintenance Guide. Fire Door Maintenance Guide http://www.c-sgroup.co.uk/products/acrovyn-impact-resistant-doors/ Introduction Fire Doors are a critical safety feature of any building in which people work or visit, as they

More information

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS Mandatory Fire Safety Instruction NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS Reference A: Reference B: Approved Document B

More information

PROFESSIONAL KITCHEN CLEANING. New Kitchen Ventilation Systems supplied and fitted at competitive rates

PROFESSIONAL KITCHEN CLEANING. New Kitchen Ventilation Systems supplied and fitted at competitive rates New Kitchen Ventilation Systems supplied and fitted at competitive rates About Us As a restaurant owner for over 25 years, I became aware of the difficulties of obtaining the services of a professional

More information

PERIODIC ELECTRICAL TESTING POLICY

PERIODIC ELECTRICAL TESTING POLICY PERIODIC ELECTRICAL TESTING POLICY Originator: Policy and Strategy Team Approval date: 19 July 2016 Review date: d July 2017 1 Introduction 1.1 1.2 Pine Court Housing Association (PCHA) treats the health

More information

THE LOCAL GOVERNMENT GROUP GUIDE: FIRE SAFETY IN PURPOSE-BUILT BLOCKS OF FLATS

THE LOCAL GOVERNMENT GROUP GUIDE: FIRE SAFETY IN PURPOSE-BUILT BLOCKS OF FLATS DERBY HOMES BOARD 24 NOVEMBER 2011 ITEM C5 THE LOCAL GOVERNMENT GROUP GUIDE: FIRE SAFETY IN PURPOSE-BUILT BLOCKS OF FLATS Report of the Chief Executive 1. SUMMARY This report provides a brief overview

More information

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide BWF-Certifire Fire Doors and Doorsets Best Practice Guide 1 BWF-Certifire BWF-Certifire: The leading authority on fire door safety A fire door is a vital safety device engineered to save lives and property.

More information

Technical Bulletin CE marking: from 1st July 2013

Technical Bulletin CE marking: from 1st July 2013 Technical Bulletin CE marking: from 1st July 2013 New regulation New obligations Same CE mark We are facing the most significant change for a decade in the way that construction products are manufactured

More information

Periodic Electrical Testing Policy

Periodic Electrical Testing Policy Periodic Electrical Testing Policy Originator: Executive Management Team Approval Date: Policy and Strategy Team 18 July 2017 Review date: July 2018 1 Introduction 1.1 1.2 OVH treats the health and safety

More information

GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017

GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017 GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017 OBJECTIVE This policy is designed to help our school comply with our duties under the Regulatory Reform (Fire Safety Order) 2005. Contents:

More information

Design Guidelines Fire Safety in New and Refurbished Buildings

Design Guidelines Fire Safety in New and Refurbished Buildings Design Guidelines Fire Safety in New and Refurbished Buildings Introduction All major new or refurbishment projects must comply with the Technical Standards (Scotland) Regulations as a matter of course.

More information

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD PASSIVE FIRE PROTECTION FTI-MARNEROS LTD the art of passive fire protection since 1989 ABOUT FTI - MARNEROS is the joining of the fire department of Chr. Marneros & Co Ltd and Fire and Thermal Installations

More information

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article DOMESTIC SMOKE ALARMS AND SPRINKLERS Frank SWANN 1 Abstract: Key words: Making further inroads into the reduction of fire deaths and injuries in the home is a clear ambition of the UK Chief Fire Officers

More information

FIRE SAFETY POLICY April 2011

FIRE SAFETY POLICY April 2011 FIRE SAFETY POLICY April 2011 CONTENTS Page No 1.0 Statement of Intent 1 2.0 Fire Safety Accountability Structure 2 3.0 Roles and Responsibilities 3 4.0 Fire Safety Management 7 5.0 Fire Risk Assessment

More information

Fire Safety. A TUC guide for trade union activists

Fire Safety. A TUC guide for trade union activists Fire Safety A TUC guide for trade union activists Contents Section one Introduction 3 Section two The law 4 Section three Fire risk assesment 5 Section four Policies and procedures 6 Section five Enforcement

More information

Fire Safety Policy SH HS 06. Version: 4. Summary:

Fire Safety Policy SH HS 06. Version: 4. Summary: SH HS 06 Fire Safety Policy Summary: Keywords: Target Audience: The Fire Safety Policy sets out the Trusts approach to a proactive fire safety culture to protect its staff, patients, service users, all

More information

Dispute over the requirement for fire door signage to hotel suites at 124 Devon Street West, New Plymouth

Dispute over the requirement for fire door signage to hotel suites at 124 Devon Street West, New Plymouth Determination 2016/058 Dispute over the requirement for fire door signage to hotel suites at 124 Devon Street West, New Plymouth Summary This determination considers whether signage is required between

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1500: Issue 2.1 provide compartmentation in buildings This standard defines the requirements for companies installing fire resisting compartment systems approved by LPCB to

More information

Fire Safety Management

Fire Safety Management POLICY Fire Safety Management Policy Owners Policy Holder Author DCC Norfolk / DCC Suffolk Health & Safety Health & Safety Manager Estates Manager Policy No. 66 Approved by Legal Services 25.09.15. Policy

More information

To seek Cabinet approval of the Council s Fire Safety Policy. It is proposed that Cabinet approves the Fire Safety Policy.

To seek Cabinet approval of the Council s Fire Safety Policy. It is proposed that Cabinet approves the Fire Safety Policy. NORTH AYRSHIRE COUNCIL Cabinet 1 May 2018 Title: Purpose: Recommendation: Fire Safety Policy To seek Cabinet approval of the Council s Fire Safety Policy. It is proposed that Cabinet approves the Fire

More information

Local Rules: Fire Safety

Local Rules: Fire Safety 1. Potential Effects of a Fire A small fire is most likely to cause damage to equipment and furniture, with the potential to cause additional smoke damage to the room of origin. A large and protracted

More information

GDST Fire Safety Strategy March 2016

GDST Fire Safety Strategy March 2016 GDST Fire Safety Strategy March 2016 GDST Fire Safety Strategy v1.0 March 2016 Page 1 of 17 Contents 1. Introduction 3 2. Compliance Statement 3 3. Fire Safety Strategy Aims and Objectives 3 Strategic

More information

Colt International Ltd Commissioning and maintenance of smoke control systems CPD Technical Seminar

Colt International Ltd Commissioning and maintenance of smoke control systems CPD Technical Seminar Colt International Ltd Commissioning and maintenance of smoke control systems CPD Technical Seminar People feel better in Colt conditions www.coltinfo.co.uk People feel better in in Colt conditions www.coltgroup.com

More information

Fire safety procedure

Fire safety procedure Fire safety procedure Review date: October 2020 Responsible (s): Health and Safety Applicable to Staff: Accessible to Students: Accessible to general public: (including clients) Yes Yes Yes 1 Contents

More information

REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION LEVEL 4 CERTIFICATE IN GAS SAFETY MANAGEMENT IN SOCIAL HOUSING (601/1725/4) 1.0 Area and scope of

More information

Third Party Certification:

Third Party Certification: Third Party Certification: What does it mean for businesses? Introduction If you work in any part of the fire safety industry you will at least have heard of Third Party Certification (TPC) but you may

More information

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION LEVEL 4 CERTIFICATE IN GAS SAFETY MANAGEMENT IN RESIDENTIAL PREMISES (601/0956/8) 1.0 Area and scope

More information

NOTTINGHAM CITY HOMES

NOTTINGHAM CITY HOMES APPENDIX 1 NOTTINGHAM CITY HOMES FIRE SAFETY POLICY 2013/14 Draft for Board Uncontrolled when printed Page 1 of 14 DOCUMENT CONTROL Identification and Approval Status Document Title: Nottingham City Homes

More information

Joint Responsibility for Health and Safety Internal Guidance for Members and other occupiers of the Scottish Parliament Campus.

Joint Responsibility for Health and Safety Internal Guidance for Members and other occupiers of the Scottish Parliament Campus. To: Leadership Group From: Jake Fenton Extension: 86917 Date: 17/5/12 Dear Colleague, S. Joint Responsibility for Health and Safety Internal Guidance for Members and other occupiers of the Scottish Parliament

More information