Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Size: px
Start display at page:

Download "Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4"

Transcription

1 Table of Contents Page Quick Set-up Instructions 1 Theory of Operation 2 Specifications 3 TM 1003W Controls and Connections 4 1. Power Source Connector 5 2. Alarm Output Connector 5 3. Variation Detection Lamp 6 4. Defect Detection and Sensitivity Adjustment 6 5. Sensitivity Level Monitor Terminals 8 6. Recorder Output Terminals 8 7. Gain Adjustment VR 8 Calibration Instructions 9 Sensor Output Values Table 11 Optional Comparator Module

2 QUICK SET-UP INSTRUCTIONS 1. Carefully unpack the instrument and lay the contents on a table. You should have the following: A. (1) TM-1003W Surface Variation/ Flaw Detector B. (1) ± 15 VDC regulated power supply with attached DC power cable C. (1) 115 VAC power cable attached to the power supply D. (8) Connectors for monitor and recorder outputs E. (1) Alarm output interface cable 2. Attach the DC power cable to the TM-1003W 3. Attach the alarm output interface cable to the TM-1003W 4. Mount the TM-1003W on-line 5. Using a small screwdriver, adjust the sensitivity adjustment potentiometer and measure the monitor output voltage level to correspond to the defect height you want to detect, refer to the table on pages 11 and 12 for defect size and voltage relationships. Turning the potentiometer counter-clockwise increases the TM sensitivity to detect smaller defects. Conversely, a clockwise adjustment decreases the TM sensitivity to detect larger variations and ignore the smaller ones. If you are using a TM 1003W with a digital dial sensitivity adjustment, simply adjust to the desired defect size limit. The setting is in mm millimeters. Please refer to 4d for more information. NOTE: This detector has been factory calibrated, and as such, DO NOT adjust the (3) gain potentiometers. Should you have any questions, contact Takikawa at

3 Theory of Operation When a normal object is passed through the parallel light beams, the light volume produces a null (A1-A2). When an object with a lump or bump is passed through the beams, the values A1 and A2 become unbalanced. The difference between A1 and A2 is in proportion to the size of the flaw (lump/bump). When these features exceed a preset value an alarm is output

4 SPECIFICATIONS: 1. Measuring range: (optical shield hole Diameter 0.314, Range can be extended to with vibration less than ± 0.2mm) 2. Measuring area: x (3 axes) 3. Light source: Near-Infrared LED 720 nm 100,000 hours life expectancy 4. Light receiver element: Photo diode 5. Detector sensitivity: (10µm) (5µm if used with DSS processor) 6. Detection accuracy: ± 2% or less of max set value 7. Line speed: 5 ft/min 4500 ft/min 8. Recorder output: ± 50 mv/ 0.01mm 9. Alarm output:tm-1003w: Red-lamp annunciator/ relay with 0.5 sec off-delay 250V 2 amp Resistive load 250V 0.1 amp Inductive load TM-1003W-S: Red-lamp annunciator Open-collector output 0.025sec one shot. (50V max, 150mA max, PC = 100mW max) 10. Ambient temperature: -5 C - 50 C (Subject to no condensation) 11. Power source: ± 15V (± 5% or less) +0.07A, -0.02A 12. Weight: 0.8 Kg 13. Frequency:TM-1003W: 15Hz 10KHz (-3db). TM-1003W-30: 15Hz 30KHz (-3db). TM-1003W-50: 15Hz 50KHz (-3db). 14. Noise Level: ± 1.6µm ± 3µm depending on model NOTE: The optical shield is typically used for very fine wire <0.2 mm. For larger wire, the two shields may be removed

5 TM 1003W Controls and Connections Standard Model Digital Dial Model 1. Power Source Connector 2. Alarm Output Connector 3. Variation Detection Lamp 4. Alarm Sensitivity Adjustment 5. Sensitivity Level Monitor Terminals 6. Recorder Output Terminals 7. Gain Adjusting VR - 5 -

6 1. Power Source Connector (3 Terminal ± 15VDC Regulated Power Supply) Terminal # 1 0V (Black) 2 +15V 0.07A (White) 3 15V 0.02A (Red) NOTE: Terminal # 1 is larger than 2 and 3. 2a. Relay Alarm Output 2 Terminal Connector (Standard Model) 1 2 (250V 2A Resistance Load, 250V 0.1A Inductive Load) The relay contact closure will occur between terminals 1 and 2 for 0.5 seconds. 2b. Transistor Alarm Output (Optional) Terminal # 1 = + (White) 2 = (Black) NOTE: Terminal # 1 is larger than #2. NPN Open-Collector Transistor Maximum Current: 150mA Applied Voltage: 50VDC or less Maximum Residual Voltage: 250mV Off Delay Time: 25ms - 6 -

7 3. Variation Detection Lamp Will be illuminated at each detection for 0.5 sec for the standard relay model. 4a. Defect Detection and Sensitivity Adjustment The TM-1003W is a high-speed defect detector, which utilizes a continuous sensing method for repeatable and cost effective detection of defects as small as 10 µm on wire and fiber. 5 µm defect detection is possible using our TM DSS defect analysis system. A dual parallel Photo- optic slit technique combined with Infrared light source is used to measure rapid light volume changes created when a sudden change in product diameter occurs. This diameter change is caused by the flaw, bump, neck down, color skip, etc. The light volume received is converted to a Real time analog signal, which is then analyzed through a differential circuit. The actual throughput speed is limited by the design of the circuits used, i.e. light modulation and filtering techniques. However, 5 µm defects can be characterized at speed greater than 15 m/sec. The sketch below illustrates how a defect may appear as it passes through the TM defect detectors two parallel photo- optic slits. And although the defect height may be the same, the actual light volume received can be different due to defect size characteristics. As such allowances should be made to adjust the TM sensitivity lower for these variations. Fig A. Fig B. Fig C. In figure A the defect creates a shadow that takes up the entire photo- optic slit. The defect is detected as a 0.5 mm high defect. In figure B the defect is detected as a 0.25 mm high defect. In figure C the defect is detected as a mm high defect. Using the above comparison, it is suggested that the TM 1003W s sensitivity be set to the lowest possible setting (without false triggering) for very small defect detection on small diameter wire and optical fibers

8 4b. Calculating Defect Size for Proper Sensitivity Adjustment 1. The formula for calculating a defect size which is smaller than the TM 0.5mm optical slit width shall be: Length (mm) x Width (mm) 0.5mm 2. Deviated Projection: When the point of the projection (Defect) leans by a certain degree against the emitted beam direction, as shown below, the detected height becomes smaller than the actual one. To prevent from misdetection, the actual variation width (height) shall be calculated using the following formula: h= ½ φ (cos α - 1) + Hcos α For such application, detection by multi-direction shall be required. 4c. Alarm Sensitivity Adjustment (Standard Model) 1. Determine the size of the variation/flaw you wish to detect. 2. Attach a digital multimeter (DMM) to the sensitivity level monitor terminals. 3. Adjust the sensitivity potentiometer to change the voltage level at the monitor output to be in proportion to the defect size. (0.05V/ ± 0.01mm) To increase the sensitivity to detect smaller defects turn the potentiometer counter clockwise. To decrease the sensitivity to only detect larger variations turn the potentiometer clockwise

9 4d. Alarm Sensitivity Adjustment (Digital Dial Model) To set the sensitivity on the digital dial model set the dial display to the defect to detect from 20 to 999 µm. Example to detect a defect 0.04 mm set the dial to Sensitivity Level Monitor Terminals Monitor with a DMM that has an impedance of 1 MΩ or more for alarm sensitivity adjustment. (Does not apply to Digital dial models.) 6. Recorder Output Terminals Output Impedance = 100 Ohms ± 50mV/ uneven ±01V max. 7. Gain Adjusting VR The TM 1003W has been calibrated at the factory and should require a calibration check at yearly intervals to ensure optimum performance. DAS Distribution Inc. provides this annual service as part of a 17-point inspection test. (See Test Certificate on Page 16) Takikawa also offers an optional calibration gage kit (P/N: TMG 05) for this purpose, should the user wish to check the linearity of the recorder output only

10 Calibration Instructions 1. Remove the detection area protection covers and clean the emitter/ receiver lenses with alcohol and a lint free cotton cloth, or optical glass cleaner. Ensure that there is no left over residue on the lens. 2. Re attach the protection covers and attach the 0.5 mm gage pin (P/N: TMG 05) to the TM 1003W center detecting area. 3. Attach an oscilloscope or high-speed analog processor to the number 1 recorder output terminals. 4. Press the cable trigger button and note that the 0.5mm gage pin moves horizontally through the center portion of the detecting area. The in and out movement of the pin must be done quickly (within 0.5 sec. or less) to accurately simulate a 0.5mm defect. 5. While moving the gage pin in and out monitor the output reading on the oscilloscope. A 0.5mm defect should produce an output pulse of 2.5V. 6. Adjust the number 1 gain potentiometer so that the output pulse is within ±0.1V of 2.5V. Note that when the gage pin is retracted there will be a dent signal. Disregard this signal. Calibration is done with the gage pin projection only. 7. Repeat the above steps for recorder outputs 2 and 3 using their respective gain potentiometers

11 TMG-05 Gage Unit

12 Sensor Output Values Defect size Output inches Meters Millimeters Microns Voltage

13 Defect size Output inches Meters Millimeters Microns Voltage E E E E E E E E E

14 Optional Comparator Module Function: This module is used if two different size defects need to be detected. The module mounts on the side of the TM 1003W and plugs in to the monitor terminal and recorder output terminals. Specifications Input: L Output: 4ch (3ch for variations, 1ch for monitor. 0 ~ ± 10V, ± 0.05V/ ± 0.01mm Red lamp lighting and relay connector Output = 0.05 sec one shot per detection. (250V 2A Resistance load, 250V 0.1A Inductive load) Monitor: Alarm level voltage monitor terminal for small variation = ± 0.05V/ 0.01mm. Alarm level voltage monitor terminal for large variation = ± 0.05V/ 0.01mm. L Alarm setting: 15 turn potentiometer Power: + 15V 0.03A - 15V 0.01A DC power, with ripple Voltage of 3mVp-p or less

15 Installation 1. Remove 2 screws from TM 1003W (Refer to drawing on proceeding page.). 2. Plug the Comparator module into the Level monitor and recorder output terminals. Secure the module to the TM 1003W with the two screws removed in step Attach the power and relay cobles to the TM unit and the comparator module. 4. Set the voltage for the smaller variation by using a Digital Multimeter in the Lo terminal and adjusting the Potentiometer on the TM 1003W. 5. Switch the meter to the Hi terminals and set the voltage for the larger variation by adjusting the potentiometer on the comparator module

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 13 Sensor SERIES Related Information General terms and conditions... F-17 About laser beam... P.13~ Sensor selection guide... P.967~ General precautions... P.1 PHOTO PHOTO Conforming to EMC Directive Conforming

More information

Laser Collimated Beam Sensor

Laser Collimated Beam Sensor SERIES Laser Collimated Beam Sensor Class 1 Laser Beam Sensor Safe for Your Eyes Marked Conforming to EMC Directive (Excluding LA-C1) Safe Laser Beam This laser collimated beam sensor conforms to the Class

More information

Ultrasonic Proximity Sensor

Ultrasonic Proximity Sensor Ultrasonic Proximity Sensor Compact, Column-shaped Sensor Capable of Sensing Range Setting Ensures the stable detection of a variety of objects regardless of the color, transparency, or material (metallic

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

Datasheet: K-22 LO Sensor

Datasheet: K-22 LO Sensor Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter

More information

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable R Label Detection Sensor E3S-CD68/63 Detect Labels Regardless of Label Color or Luster, Bottle Color or Clarity H High-performance circuitry detects wide variety of labels on clear and colored bottles

More information

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet. Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) LS-1310/1550 Service Information Sheet Introduction This Service Information Sheet provides the following service information

More information

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P BYD Series Small diffuse reflective and convergent reflective type Features Easy installation by compact size Superior detection not affected by color of (Convergent reflective type) is located on the

More information

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Date: 2016.3.24 Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Symbol Amended Reason Pages Date Corrector Amendment No Approved by Checked by Drawn by Designed by UST-10LN Specification

More information

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA MX1A and MX1B: Laser Displacement Detection MX1A and MX1B: Laser Displacement Detection Built-in math capabilities available (MX1B only) Digital display on amplifier; easy setting and monitoring (MX1B

More information

The reprint reproduction or disclosure of this material to the third party is prohibited. PARTICULATE MATTER SENSOR. Introduction of

The reprint reproduction or disclosure of this material to the third party is prohibited. PARTICULATE MATTER SENSOR. Introduction of 1 PARTICULATE MATTER SENSOR Introduction of 2017.12.1 2 What is PPD? PPD=Photo Particle Detector Detects airborne particles continuously, then outputs the detection result in UART digital output based

More information

GAS MONITOR Model Model

GAS MONITOR Model Model Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-mail: sierra@sierramonitor.com Web Site: www.sierramonitor.com GAS MONITOR Model 2350-00

More information

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity Scanning HOT METAL DETECTOR Rota-Sonde DC4000-L Two sensitivity ranges : 400 C and 230 C Laser pointer for easy alignment Remote control of the sensitivity Self-monitoring ISO 9001 Applications Benefits

More information

2 General Application Photoelectric Sensors

2 General Application Photoelectric Sensors MITY EYE General Purpose Photoelectric Sensor 2 General Application Photoelectric Sensors 2-49 General Application Photoelectric Sensors 2 MITY EYE Designed for Trouble-Free Operation Many design features

More information

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Modus Model DA General Eastern Low Differential Pressure Alarm Controller GE Sensing & Inspection Technologies Modus Model DA General Eastern Low Differential Alarm Controller The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines

More information

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE Exercise 1 Introduction to Sensors EXERCISE OBJECTIVE When you have completed this exercise, you will be introduced to photoelectric, capacitive and inductive sensors; You will also be introduced to the

More information

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

IRtech. E instruments. IRtech Radiamatic IR20 LS series.  Infrared Technology E instruments IRtech Temperature range up to 2200 C Optical resolution up to 300:1 Close focus 0,5mm 8-14µm, 1.6µm, 1µm, 2.3µm, 3.9µm, 4.2µm, 4.6µm, 5.1µm and 7.9µm Spectral response Dual laser true target

More information

English. Series. Installation and Use Manual

English. Series. Installation and Use Manual English Series FOSTER Installation and Use Manual FOSTER Rev.13 03/2015 MITECH srl reserves the right to change the information in this document without warning. Index Anti-intrusion barrier 3 Main components

More information

2 General Application Photoelectric Sensors

2 General Application Photoelectric Sensors 2 General Application Photoelectric Sensors General Purpose Photoelectric Sensor 2-49 General Application Photoelectric Sensors 2 Designed for Trouble-Free Operation Many design features have been incorporated

More information

vibration switch

vibration switch user manual 440-450 vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0592822_A ISSUED 06/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Section 1 -

More information

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000. INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA

More information

UDC100 Universal Digital Controller Specifications

UDC100 Universal Digital Controller Specifications UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

High Reliability Of Fiber Optic Amplifier For Convenient Mounting Fiber Optic Amplifier Reliability Of Fiber Optic Amplifier For Convenient Mounting Features speed response: Max. 0.5ms Auto sensitivity setting (Button setting)/remote sensitivity setting External synchronization

More information

Ultrasonic Proximity Sensor

Ultrasonic Proximity Sensor Ultrasonic Proximity Sensor Compact, Cylindrical Ultrasonic Proximity Sensor with Separate Amplifier Unit Stable operation for a variety of objects regardless of color, transparency, or material (metallic

More information

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M PHOTOELECTRIC SENSORS EFA/B_-F Special family with inverted output logic Fully compatible with previous EF family Simple installation due to compact format Wide variety of models Ordering Information EFA/B

More information

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must

More information

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor

More information

Laser Distance Sensor Type M Analog-Output

Laser Distance Sensor Type M Analog-Output Laser Distance Sensor Type M Analog-Output Operating Manual Version 2.3, May 2009 ELAG Elektronik AG l Stegackerstrasse 14 l CH-8409 Winterthur Contents 1. Safety 1.1 Laser safety 1.2 Electrical safety

More information

More Precision. thicknesssensor // The sensor for precise thickness measurements

More Precision. thicknesssensor // The sensor for precise thickness measurements More Precision thicknesssensor // The sensor for precise thickness measurements 2 The sensor for precise thickness measurements thicknesssensor - Immediately ready for use due to perfectly harmonized components

More information

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423 Laser Scan Micrometers Laser Scan Micrometer Page 418 Laser Scan Micrometer Measuring Unit and Display Unit Package Page 419 Laser Scan Micrometer Measuring Unit Page 420 Laser Scan Micrometer Page 423

More information

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Sierra Series 900 Single & Dual Channel System. Instruction Manual Series 240/24 Instruction Manual Table of Contents Sierra Series 900 Single & Dual Channel System Instruction Manual Part Number IM-90-07/05 Revision D. 5 Harris Court, Building L Monterey, CA 93940 (83)

More information

NIDS Dust sensor ED-N-DS-1408

NIDS Dust sensor ED-N-DS-1408 SPECIFICATION (Tentative) Product Name: Dust Sensor(High Sensitivity) Model No. : SM-PWM-01A-HS SMART dust sensor for air purifier SM-PWM-01A-HS Description SM-PWM-01A-HS is a dust sensor that detects

More information

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features Application Note SMART Dust Sensor SM-PWM-01C SM-PWM-01C dust sensor detects dust particle concentration in air by using an optical sensing method. An infrared light emitting diode (IR LED) and a photo-sensor

More information

2 General Application Photoelectric Sensors

2 General Application Photoelectric Sensors SMARTEYE PRO/PRO 2 General Application Photoelectric Sensors Self-Adjusting General Purpose Sensor www.ttco.com 800-237-0946 2-7 General Application Photoelectric Sensors 2 SMARTEYE PRO/PRO The SMARTEYE

More information

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12 SHORT FORM SENSORS A new performance class of innovative sensor technology The delivery program: innovative and extensive. Besides throughbeam and retro reflective types, reflective sensors and optical

More information

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web:  - The sensor is designed for frequent washdowns with a corrosion-resistant AISI316L stainless steel case IP69K rated, compliant to test environments like indicated by Diversey and Ecolab. However, all models

More information

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web: AAS-920-668A Nov., 2015 2015 Amphenol Advanced Sensors Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China Web: www.amphenol-sensors.com Table of Contents 1. Description...................................................................

More information

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12 SPECIFICATION Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12 SM-PWM-01A SMART dust sensor for home appliance Description SM-PWM-01A is a dust sensor that detects the dust particle concentration

More information

2 General Application Photoelectric Sensors

2 General Application Photoelectric Sensors SMARTEYE PRO/PRO REMOTE General Purpose Photoelectric Sensor 2 General Application Photoelectric Sensors 2-7 General Application Photoelectric Sensors 2 SMARTEYE PRO/PRO REMOTE The SMARTEYE PRO is not

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

User Detection Sensors

User Detection Sensors User Detection Sensors Design Team 5 Kevin Harrison Eric Hosey Leslie Hodges Nathan Kelly Berna Saracoglu Agenda Sensing Technologies Infrared Ultrasonic Capacitive Pressure Video Image Key Points Theory

More information

Specifications Wavelength Range: 190 nm to 800 nm continuous

Specifications Wavelength Range: 190 nm to 800 nm continuous www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 for Certified, Refurbished Lab Equipment Thermo Finnigan Surveyor PDA Detector Specifications Wavelength Range: 190

More information

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS OPERATION MANUAL THE JENCO MODELS 3672, 3673, 3675 1/4 DIN ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS INTENDED USE AND GENERAL INTRODUCTION The models 3672, 3673 and

More information

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract FEATURE ARTICLE Technical Reports The PLCA-800 Series Inline Particle Sensor for Chemical Solutions Yoshihito Yuhara Front end process Sensor module Wafer preparation process Film formation Photo lithography

More information

Operating Instructions. For. Alarm Control Module. Model SSR 500

Operating Instructions. For. Alarm Control Module. Model SSR 500 SSR 500 LEVEL CONTROL RELAY MODULE Operating Instructions For Alarm Control Module Model SSR 500 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions

More information

DGC-500 DIGITAL GENSET CONTROLLER

DGC-500 DIGITAL GENSET CONTROLLER DGC-500 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-500) offers a low cost microprocessor based integrated alternative for the control and monitoring of small to medium sized

More information

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F: gray Instruction Manual for gray Mounted Detectors F: +41 44 633 13 68 2 / 12 gray Mounted Detectors: Instruction Manual CONTENT 1. SHORT USER GUIDE... 4 2. THERMAL INTEGRATION OF THE DETECTOR... 5 2.1.

More information

E3M-V. Mark Sensor. Applications

E3M-V. Mark Sensor. Applications Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy grasp

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

Automatic Self-Adjusting General Purpose Sensor

Automatic Self-Adjusting General Purpose Sensor SMARTEYE EZ-PRO 2 General Application Photoelectric Sensors Automatic Self-Adjusting General Purpose Sensor 2-1 General Application Photoelectric Sensors 2 SMARTEYE EZ-PRO The SMARTEYE EZ-PRO is a high

More information

Web Site: Forums: forums.parallax.com Sales: Technical:

Web Site:  Forums: forums.parallax.com Sales: Technical: Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267

More information

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION 968 AFMS AFMS TECHNICAL SPECIFICATION 08/07 Ref B ATV-ELEKTRONIK GMBH WIENER STRASSE 228 A-4030 LINZ +43 732 301600 FAX. +43 732 301600 21 Page 2 Table of contents General Introduction...3 Overview...3

More information

PUV, PIR and PFO Series BROCHURE

PUV, PIR and PFO Series BROCHURE PUV, PIR and PFO Series BROCHURE JUNHO 2013 ABB Multiwave TM process photometers PUV3402, PIR3502 and PFO3372 Measure vapor and liquid samples in IR, NIR, UV and VIS regions Process photometers PUV3402,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Loop Alarm Models SC1090 and SCL1090 INSTALLATI INSTRUCTIS LOVE LOVE CTROLS a Division of Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX (219)

More information

5.0. Photoelectric Sensors. Technical Reference. Introduction

5.0. Photoelectric Sensors. Technical Reference. Introduction .0 Technical Reference Photoelectric sensors use light to detect the presence or absence of an object. The main advantages of photoelectric sensors are noncontact sensing of objects and greatly extended

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11 Table of Contents INTRODUCTION 1 THEORY OR OPERATION 2 DESCRIPTION 5 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 SPECIFICATIONS 10 OPTIONS

More information

Model 3300 Technical Support and Installation Manual

Model 3300 Technical Support and Installation Manual Model 3300 Technical Support and Installation Manual Manual # T15011 Document Revision: A1 1. OVERVIEW 1 2. BASIC OPERATION 1 2.1 General 1 2.2 Field-of-View 2 2.3 Range 2 2.4 Environment 2 2.5 Configuration

More information

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS

More information

Retroreflective sensor with polarization filter

Retroreflective sensor with polarization filter Dimensions 45 49 Receiver 23 27 74 56 Emitter 92 23 6 x 9 slots External thread (M30 x 1.5) 10 25 32 M12 x 1 Sens Delay IMER Model Number Retroreflective sensor with 4-pin, M12 x 1 connector Electrical

More information

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL temperature / static pressure DIFF Opn Clo ALARM HI F2 DELAY ALARM LO OPEN DELAY CLOSE ADJUST Varifan + CPS-1 CPS-1 Although the manufacturer has made every

More information

Exercise 1: IR Transmission and Reception

Exercise 1: IR Transmission and Reception Exercise 1: IR Transmission and Reception EXERCISE OBJECTIVE When you have completed this exercise, you will be able to explain how infrared light can be transmitted and received, describe typical infrared

More information

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing Dimensioned drawing en 1-214/7 5122143 3 Hz.5 26m We reserve the right to make changes DS_PRKL2566P_en_5122143.fm 1-3 V D 2 LS Laser class 1 acc. to EN 6825-1 Polarized retro-reflective photoelectric sensor

More information

Web Site: Forums: forums.parallax.com Sales: Technical:

Web Site:   Forums: forums.parallax.com Sales: Technical: Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267

More information

RTD TEMPERATURE SENSING SYSTEM

RTD TEMPERATURE SENSING SYSTEM General Overview RTD TEMPERATURE SENSING SYSTEM The Prime Technology RTD Temperature System 9219-00-0002 is a three-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs

More information

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800 SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical

More information

JENCO ELECTRONICS, LTD.

JENCO ELECTRONICS, LTD. OPERATION MANUAL THE JENCO MODEL 3677 1/8 DIN ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISON INSTRUMENTS GENERAL INTRODUCTION The model 3677 is a precise instrument for the measurement

More information

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved RED1 Models ST, E1, E2, E3, E4, and 420 Technical Support And Installation Manual 210111 FM Approved 1. OVERVIEW 1 2. BASIC OPERATION 3 2.1 General 3 2.2 Field-of-View 4 2.3 Range 4 2.4 Environment 4 2.5

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Loop Alarm Model SC1290 and SCL1290 INSTALLATION INSTRUCTIONS LOVE LOVE CONTROLS a Division of Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

HOA0880-T51. Representative photograph, actual product appearance may vary.

HOA0880-T51. Representative photograph, actual product appearance may vary. Representative photograph, actual product appearance may vary. HOA0880-T51 HOA Series Infrared Transmissive Sensor, Transistor Output, Two- Mounting Tabs, Plastic package Due to regional agency approval

More information

IR FLAME DETECTOR RIV-601/F

IR FLAME DETECTOR RIV-601/F IR FLAME DETECTOR EN 54-10 class 2 VdS approval G 205044 application manual CONTROL LOGIC rev. 4 DEC07 MAFE DEC07 IR FLAME DETECTORS SUMMARY Page general notions...3 description...4. Electrical and general

More information

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m series Fiber type / CMD Self-check feature provided Within detecting distance 40 m with fiber length 2 m Transmitter and receiver as a set; dimensions same for both The sensor is composed of an optical

More information

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001 Throughbeam photoelectric sensors Dimensioned drawing 15m 1-3 V DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in infrared light Robust metal housing with glass cover, protection

More information

Model OEM-2 INSTRUCTIONS FOR USE

Model OEM-2 INSTRUCTIONS FOR USE ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set

More information

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models Series 9000 Description The Series 9000 photoelectric sensors are designed to perform in the harshest of industrial environments. The sensor will withstand 1200 psi high-pressure washdown and IP69K, which

More information

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F: gray Instruction Manual for gray Housed Detectors F: +41 44 633 13 68 info@ 2 / 10 gray Housed Detectors: Instruction Manual CONTENT 1. SHORT USER GUIDE... 4 2. THERMAL INTEGRATION OF THE DETECTOR... 5

More information

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic SPECIFICATION Product Name: Dust Sensor Model No. : SM-ND-02A ( Tentative ) SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

CP CP

CP CP CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling

More information

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions 15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.piacton.com Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

More information

STRONG International FP-350 Operation and Installation Manual

STRONG International FP-350 Operation and Installation Manual STRONG International FP-350 TM Operation and Installation Manual Revision 2.00 June 2005 . FP-350 OPTICAL FAILSAFE & PROXIMITY CUE DETECTOR STRONG FP-350 Installation, Setup and Operation Manual PR016

More information

DUAL OPTIC. Installation manual

DUAL OPTIC. Installation manual DUAL OPTIC Installation manual INDEX 1 COMPONENTS Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION EXAMPLES Pag. 6 4 CABLES AND CABLING Pag. 7 CONNECTION AND HEATING SETTING

More information

1. Quick start-up guide

1. Quick start-up guide 1. Quick start-up guide This quick guide leads the way to install, start-up and configure necessary parameters in the normal cases. 1. PREPARING INSTALLATION Install fiber optic cable inside conduit. This

More information

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers 687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global

More information

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors More Precision indusensor // Linear inductive displacement sensors 4 Gauges with external controller indusensor LVDT - Proven LVDT technology - Measuring ranges ±1 ±10mm - Excellent price/performance ratio,

More information

S304 and S305 Dust Emission Monitors. User Manual. Distributor

S304 and S305 Dust Emission Monitors. User Manual. Distributor S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL General information The CX10 provides a priority input into an audio system of up to 10 channels in a 19 1RU package. The CX10 may be used with

More information

Quadruple-beam photoelectric detector

Quadruple-beam photoelectric detector New generation 4-channel selectable frequencies abh-50/100/150/200/250m Quadruple-beam photoelectric detector Highly Reliable Photoelectric Detector ABH series quadruple-beam photoelectric detector with

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS6-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS6-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

More Precision. indusensor Linear inductive displacement sensors

More Precision. indusensor Linear inductive displacement sensors More Precision. indusensor Linear inductive displacement sensors - 1 - Standard sensors 4 LVDT series - gauges with external controller Proven LVDT technology Measuring ranges ±1 ±10mm Excellent price/performance

More information

RS Pro Infrared Temperature Sensor

RS Pro Infrared Temperature Sensor Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid

More information

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800 SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical

More information

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN ITS SURROUNDINGS..

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA - FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION Up to 6 WEEKS PRINTED RECORD (Optional)