1 April B

2 able of Contents Introduction...3 Installation...3 Wiring Connections... 3 Dimensions...4 Wiring Layout... 4 erminator...5 esting and roubleshooting...5 Recommended Ground Wiring Practices... 6 CE Conformity... 6 Operation...6 Maintenance... 6 Customer Support...6

3 Introduction he RUNKGUARD Fieldbus Power Conditioner enables fast and easy implementation of fieldbus systems by providing properly conditioned power for Foundation fieldbus (H) networks. he is fully compliant with FF83- (the technical specification for fieldbus power supplies) and is FOUNDAION fieldbus registered. he is composed of a multi-position DIN Carrier populated with individual Power Conditioner Modules. o accommodate segment changes or additions, Power Conditioner Modules can be added, or removed, from the carrier without affecting power or fieldbus communications on any other segment. Built in connectors accept one or two DC (8-3V) power supply inputs. he provides fieldbus conditioning via FPS0 Segment Power Conditioner modules, incorporating DC/DC isolation and signal filtering. he Segment Power Conditioners are fitted onto a FPS0 Carrier which provides connection facilities for DC power (one or two, as required) for both system- and field-side segment wiring. he Carrier also includes a switchable terminator per segment. Redundant configurations use two FPS0 Segment Power Conditioners per segment. Refer to the latest product Data Sheet for full technical information. Visit our website at Installation FPS0 Carrier Units Each unit is designed to fit onto a 3mm (EN50035) G-type and 35mm (EN500) op Hat DIN-rail and should be mounted in such a way as to allow easy access to terminal receptacles and to keep LEDs visible. Horizontal DIN-rails are preferred so that air can flow vertically between the Conditioners to assist in module cooling. An outdoor location will require an external enclosure. Any enclosure meeting the requirements of the location in relation to electrical and mechanical safety can be used (a minimum of IP54 recommended). Contact MooreHawke for specific advice regarding installation of Series in any hazardous area. FPS0 Segment Power Conditioner Segment Power Conditioners fit onto the sockets on the Carrier face. hey only mount in one orientation. A screw (accessible through the top of the Segment Conditioner) is used to secure the module to the Carrier. For duplex (redundant) operation, two Segment Power Conditioners are required. Wiring Connections For wire terminations, cables should be stripped to expose no more than 8mm (0.3 in) of conductor and inserted fully into the terminal opening. Bootlace ferrules are recommended for use with stranded cable. Field-side segment wiring is made via screw clamp terminals marked. DCS connections are made either through the terminals marked SYSEM or via multi-way cables plugged directly to socket(s) A and B on board the FPS0-4 and FPS0-4-S Carriers. hese sockets accept Yokogawa AKB336 cables directly. Nominal 4Vdc (8 3V) power is required for terminals marked DC Power. Provisions are made for two independent DC feeds to the Carrier. 3

4 SURGE GROUND CONNECION SURGE GROUND CONNECION Figure. FPS0 Dimensions FPS0-4 (-S) FPS0-8 39mm (9.4 in) FPS0-5mm (4.9 in) DC POWER ALARM S S S S S S 4 3 DC POWER MOORE INDUSRIES-IN'L., INC. U.S.A. DCS CONNECION A DCS CONNECION B MOORE INDUSRIES-IN'L., INC. U.S.A. ALARM 5mm (4.9 in) 5mm (4.53 in) 3 4 S S S S FRON VIEW S S FRON VIEW SIDE VIEW Figure. Hook-Up Diagrams for Simplex and Duplex Configurations Note: If only one DC power feed is to be used, a pair of jumper wires is required to the second set of DC feed terminals to ensure that the alarm monitoring circuit operates correctly. DCS Segment DCS multi-core cable (where applicable) DC Power DCS Segment DC Power Alarm Contacts (Volt-free) Simplex Example Duplex Example Alarm Contacts (Volt-free) Field Segment Surge Ground Connection Field Segment 4

5 he FPS0-4-S has surge protection components on board, per segment, and to be effective, this Carrier type must be connected to a low-impedance ground with a direct cable equivalent to 4mm or 0 AWG. Once all wiring connections have been correctly made, all retaining screws on each module should be securely fastened and any external enclosure closed (where applicable). erminator Set the switch to position for a local terminator in that segment, if required. ermination is usually required at the Carrier, with the other terminator on the segment provided by the Device Coupler. In this configuration, there should not be a terminator in the circuit at the DCS. Contact MooreHawke if the DCS link cable is in excess of 00m (38ft). esting and roubleshooting Refer to able regarding LED indications of fault conditions. able. LED Indications Module LED Alarm LED Diagnosis ON OFF Normal condition; Modules available for use OFF OFF Fault condition; No DC power check DC supply ON ON Fault condition; One DC feed <8V check DC supply. Link both DC input terminals when using one DC feed OFF ON Fault condition; Segment short circuit check field wiring. Individual module failure replace module 5

6 Recommended Ground Wiring Practices Moore Industries recommends the following ground wiring practices: Any MooreHawke product in a metal case or housing should be grounded. he protective earth conductor must be connected to a system safety earth ground before making any other connections. All input signals to, and output signals from MooreHawke s products should be wired using a shielded, twisted pair technique. Shields are to be connected to an earth or safety ground at the unit itself. he maximum length of unshielded input and output signal wiring should be inches. Fieldbus cable shields are carried through the Carrier s input/output terminals and require a suitable, noise-free ground connection point. CE Conformity Installation of any MooreHawke products that carry CE certification (Commission Electrotechnique) must adhere to the guidelines in Recommended Ground Wiring Practices (above) in order to meet the requirements set forth in applicable EMC (Electromagnetic Compatibility) directives 89/336/EEC, EN 636. Consult the factory for the most current information on products that have been CE certified. Operation During normal operation, the GREEN LED should be lit on all working Segment Power Conditioners. If RED LED is ON, or GREEN LED is OFF, refer to the esting androubleshooting section of this document. Maintenance Series modules contain no user-serviceable parts. Non-functioning units under warranty should be returned to MooreHawke for replacement or repair. Note: he is manufactured using painted steel (Conditioners), and polyamide and polycarbonate plastics (Carriers). he user and installer should take the performance of these materials into account with regard to possible attack by aggressive substances in any specific installation. Customer Support If service assistance is ever required for an instrument in your application, refer to the back cover of this manual for the telephone numbers to MooreHawke s customer service department. If possible, make a note of the model number of the offending unit before calling. For fastest assistance, have the following available: serial number and the job and purchase order number under which it was shipped. 6

7 REURN PROCEDURES o return equipment to Moore Industries for repair, follow these four steps:. Call Moore Industries and request a Returned Material Authorization (RMA) number. Warranty Repair If you are unsure if your unit is still under warranty, we can use the unit s serial number to verify the warranty status for you over the phone. Be sure to include the RMA number on all documentation. Non-Warranty Repair If your unit is out of warranty, be prepared to give us a Purchase Order number when you call. In most cases, we will be able to quote you the repair costs at that time. he repair price you are quoted will be a Not o Exceed price, which means that the actual repair costs may be less than the quote. Be sure to include the RMA number on all documentation.. Provide us with the following documentation: a) A note listing the symptoms that indicate the unit needs repair b) Complete shipping information for return of the equipment after repair c) he name and phone number of the person to contact if questions arise at the factory 3. Use sufficient packing material and carefully pack the equipment in a sturdy shipping container. 4. Ship the equipment to the Moore Industries location nearest you. he returned equipment will be inspected and tested at the factory. A Moore Industries representative will contact the person designated on your documentation if more information is needed. he repaired equipment, or its replacement, will be returned to you in accordance with the shipping instructions furnished in your documentation. WARRANY DISCLAIMER HE COMPANY MAKES NO EXPRESS, IMPLIED OR SAUORY WARRAN- IES (INCLUDING ANY WARRANY OF MERCHANABILIY OR OF FINESS FOR A PARICULAR PURPOSE) WIH RESPEC O ANY GOODS OR SER- VICES SOLD BY HE COMPANY. HE COMPANY DISCLAIMS ALL WARRAN- IES ARISING FROM ANY COURSE OF DEALING OR RADE USAGE, AND ANY BUYER OF GOODS OR SERVICES FROM HE COMPANY ACKNOWL- EDGES HA HERE ARE NO WARRANIES IMPLIED BY CUSOM OR USAGE IN HE RADE OF HE BUYER AND OF HE COMPANY, AND HA ANY PRIOR DEALINGS OF HE BUYER WIH HE COMPANY DO NO IM- PLY HA HE COMPANY WARRANS HE GOODS OR SERVICES IN ANY WAY. ANY BUYER OF GOODS OR SERVICES FROM HE COMPANY AGREES WIH HE COMPANY HA HE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF ANY WARRANY CONCERNING HE GOODS OR SERVICES SHALL BE FOR HE COMPANY, A IS OPION, O REPAIR OR REPLACE HE GOODS OR SERVICES OR REFUND HE PURCHASE PRICE. HE COMPANY SHALL IN NO EVEN BE LIABLE FOR ANY CONSEQUENIAL OR INCIDENAL DAMAGES EVEN IF HE COMPANY FAILS IN ANY AEMP O REMEDY DEFECS IN HE GOODS OR SERVICES, BU IN SUCH CASE HE BUYER SHALL BE ENILED O NO MORE HAN A REFUND OF ALL MONIES PAID O HE COMPANY BY HE BUYER FOR PURCHASE OF HE GOODS OR SERVICES. ANY CAUSE OF ACION FOR BREACH OF ANY WARRANY BY HE COMPANY SHALL BE BARRED UNLESS HE COMPANY RECEIVES FROM HE BUYER A WRIEN NOICE OF HE ALLEGED DEFEC OR BREACH WIHIN EN DAYS FROM HE EARLIES DAE ON WHICH HE BUYER COULD REASONABLY HAVE DISCOVERED HE ALLEGED DE- FEC OR BREACH, AND NO ACION FOR HE BREACH OF ANY WAR- RANY SHALL BE COMMENCED BY HE BUYER ANY LAER HAN WELVE MONHS FROM HE EARLIES DAE ON WHICH HE BUYER COULD REASONABLY HAVE DISCOVERED HE ALLEGED DEFEC OR BREACH. REURN POLICY For a period of thirty-six (36) months from the date of shipment, and under normal conditions of use and service, Moore Industries ("he Company") will at its option replace, repair or refund the purchase price for any of its manufactured products found, upon return to the Company (transportation charges prepaid and otherwise in accordance with the return procedures established by he Company), to be defective in material or workmanship. his policy extends to the original Buyer only and not to Buyer's customers or the users of Buyer's products, unless Buyer is an engineering contractor in which case the policy shall extend to Buyer's immediate customer only. his policy shall not apply if the product has been subject to alteration, misuse, accident, neglect or improper application, installation, or operation. HE COMPANY SHALL IN NO EVEN BE LIABLE FOR ANY INCIDENAL OR CONSE- QUENIAL DAMAGES. United States info@miinet.com el: (88) FAX: (88) Australia sales@mooreind.com.au el: (0) FAX: (0) Belgium info@mooreind.be el: 03/ FAX: 03/ he Netherlands sales@mooreind.nl el: (0) FAX: (0) China sales@mooreind.sh.cn el: FAX: United Kingdom sales@mooreind.com el: FAX: Moore Industries-International, Inc. Specifications and Information subject to change without notice.

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018 March 2018 -DIN Introduction The DIN-style Alarm Trip features a solid metal housing that stands up to the continual rigors of process control and factory automation applications. Rugged and reliable,

More information

RM100S RM100S. Intrinsically-Safe Fieldbus Device Coupler. ROUTE-MASTER Fieldbus System. November A1

RM100S RM100S. Intrinsically-Safe Fieldbus Device Coupler. ROUTE-MASTER Fieldbus System. November A1 November 2013 920088A1 RM100S RM100S Introduction ROUTE-MASTER RM100S Series is a fieldbus device coupler for Foundation Fieldbus and PROFIBUS- PA segments. It offers a complete assembly of spur wiring

More information

HFA HFA. HART Fault Alarm. April B

HFA HFA. HART Fault Alarm. April B April 2016 224-747-00 B HART Fault Alarm HART Fault Alarm All product names are registered trademarks of their respective companies. HART is a registered trademark of the HART Communication Foundation.

More information

DCA-ED Direct Current Alarm, Eurocard-style with Display

DCA-ED Direct Current Alarm, Eurocard-style with Display Direct Current Alarm, Eurocard-style with Display May1990 USER S MANUAL No. 192-762-00B 1990 by Moore Industries-International, Inc. Table of Contents Introduction 1 Description 1 Calibration 3 Installation

More information

IPT 2. Current-to-Pressure (I/P) Transmitter. May B. Current-to-Pressure (I/P) Transmitter

IPT 2. Current-to-Pressure (I/P) Transmitter. May B. Current-to-Pressure (I/P) Transmitter May 008 170-730-00B IPT Current-to- (I/P) Transmitter IPT Current-to- (I/P) Transmitter All product names are registered trademarks of their respective companies. Table of Contents Introduction... 1 The

More information

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual GG-EM ENTRANCE MONITOR Installation and Operation Manual 2 GG-EM Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3-2% AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3-2% Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation..

More information

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard NH 3 2% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6

More information

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard NH 3 Operating and Instruction Manual General description. 4 Installation.. 4

More information

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard H 2-1% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation..

More information

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual GG-H2S HYDROGEN SULFIDE GAS SENSOR Installation and Operation Manual 2 GG-H2S Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3 AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual GG-NO2 NITROGEN DIOXIDE GAS SENSOR Installation and Operation Manual 2 GG-NO2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

NT DUAL CHANNEL DISPLAY. User Guide

NT DUAL CHANNEL DISPLAY. User Guide NT DUAL CHANNEL DISPLAY User Guide Table of Contents Introduction... 2 Input Signals... 2 Output Signals... 2 User Programmable Features... 2 Installation... 3 Mechanical Installation... 3 Dimensional

More information

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4

More information

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL GASGUARD O 2 Oxygen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up...

More information

Protocol Station Remote Alarm

Protocol Station Remote Alarm ADI 5135-C Certified ISO 9001 Protocol Station Remote Alarm 529 5135-01-120 529 5135-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

Single Station Remote Alarm

Single Station Remote Alarm ADI 5106C Certified ISO 9001 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual GG-CO-EXP CARBON MONOXIDE SENSOR Installation and Operation Manual 2 GG-CO-EXP Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

technical datasheet technical datasheet

technical datasheet technical datasheet technical datasheet technical datasheet F0 redundant fieldbus poer for Yokogaa CENTUM 000 R Control System Integrated redundant fieldbus poer for ALF Foundation fieldbus cards -segment redundancy High-density,

More information

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00 TM CGFS u r g e P R O T E C T I O N CurrentGuardTM Installation, Operation and Maintenance Manual 750-0098-006 A00 Surge Protective Devices CurrentGuard TM Flush Mount Table of Contents Guide to Installation

More information

MBCE-110/230FR Flame Sensor Module

MBCE-110/230FR Flame Sensor Module MBCE-1001 APRIL 13, 2012 MBCE-110/230FR Flame Sensor Module DESCRIPTION The MBCE-110/230FR modules provide visual indication and electrical outputs that signal the user regarding flame presence in a combustion

More information

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual GG-R REFRIGERANT SENSOR Installation and Operation Manual 2 GG-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual GG-VL-R REFRIGERANT VENT LINE SENSOR Installation and Operation Manual 2 GG-VL-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

PodView Level Indicator LI40 Series Manual

PodView Level Indicator LI40 Series Manual PodView Level Indicator LI40 Series Manual Flowline Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598 3015 Fax: (562) 431 8507 www.flowline.com Rev A MN204260 1 of 16 INTRODUCTION / TABLE

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated F0 -segment redundant fieldbus power system for use with Foxboro I/A Series Control System Integrated redundant fieldbus power for FBM Foundation fieldbus modules High-density, compact design Fully isolated

More information

Functional Safety Solutions

Functional Safety Solutions Demand Moore Reliability IEC 61508/61511 Solutions Line Card Functional Safety Solutions for Your Safety Instrumented System www.miinet.com Functional Safety Products Designed and Built for your Process

More information

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL GASGUARD H2S EXP Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used

More information

Installation, Operation & Service Manual

Installation, Operation & Service Manual Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and

More information

Owner & Operator s Manual. Table of Contents

Owner & Operator s Manual. Table of Contents Owner & Operator s Manual Model No. Voltage Frequency 908041/9495160 100-120V 50 60 Hz 9495161 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safety 2 Technical Data 2 Unpacking Instructions 3 General

More information

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008. All rights reserved.

More information

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120 LowProfile Series: 080 and 120 Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA 1.800.647.1911 www.tpssurge.com LOWPROFILE InstaLLatIOn, OPERatIOn

More information

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector IMPORTANT READ THIS FIRST....3 CAUTIONS... 3 AVOIDING NUISANCE ALARMS... 3 STANDARD FEATURES... 4 AVAILABLE OPTIONS... 4 PARTS DESCRIPTION... 5 FRONT PANEL

More information

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual GG-LEL2 COMBUSTIBLE GAS SENSOR Installation and Operation Manual 2 GG-LEL2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

Radiant Thermostat 519

Radiant Thermostat 519 106103_dl_02 Radiant Thermostat 519 Installation & Operation Manual Introduction The Radiant Thermostat 519 accurately controls the room and/or floor temperature for a hydronic heating zone using Pulse

More information

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Flowline, Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598-3015 Fax: (562) 431-8507 www.flowline.com 17

More information

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions 1.0 GENERAL INFORMATION Every SRH humidity sensor product is tested and calibrated before

More information

Model NT20e Installation Guide

Model NT20e Installation Guide Model NT20e Installation Guide Rev 1.4 Page 2 of 14 1. Preparing for Installation CAUTION Do not remove the NT20e from the Electro-static bag until instructed from this installation guide. The NT20e is

More information

OPERATION MANUAL Model 8011 & mA

OPERATION MANUAL Model 8011 & mA OPERATION MANUAL Model 8011 & 8021 4-20mA TE CONNECTIVITY SENSORS/// MODEL 8011 & 8021 4-20MA 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted during a period of one year

More information

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1 Table of Contents 1. Warranty... 3 2. MTCC-01-xxx overview... 4 2.1. MTCC-01-xxx specification... 4 2.2. TE cooled detector temperature

More information

MBCE-110/230FR Flame Sensor Module

MBCE-110/230FR Flame Sensor Module MBCE-1001 FEBRAURY 6, 2017 MBCE-110/230FR Flame Sensor Module exida FMEDA SIL2 SEE NOTE 1 ON PAGE 4 DESCRIPTION The MBCE-110/230FR modules provide visual indication and electrical outputs that signal the

More information

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc. Installation Manual 000 Version.0 EXP-000 HBX Control s Inc. Control s Inc. HBX EXP 000 Version.0 HBX EXP-000 EXPANSION MODULE INTRODUCTION The EXP-000 is designed to be integrated with the HBX CPU-000

More information

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX 77041-4051 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN

More information

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL. Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3

More information

SONANCE GARDEN SERIES SGS SYSTEM INSTRUCTION MANUAL

SONANCE GARDEN SERIES SGS SYSTEM INSTRUCTION MANUAL SONANCE GARDEN SERIES SGS SYSTEM INSTRUCTION MANUAL TABLE OF CONTENTS Design and Features 2 Introduction 2 Box Contents 2 Speaker Layout Planning 2 Types of Wire 3 Speaker Installation 3 Connecting the

More information

XC Portable Air Conditioning

XC Portable Air Conditioning PORTABLE AIR CONDITIONERS XC Portable Air Conditioning XC-14A, XC-22A, XC-30A Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents

More information

Panel Mounted Heat Exchangers by Dantherm, Inc.

Panel Mounted Heat Exchangers by Dantherm, Inc. Panel Mounted Heat Exchangers by Dantherm, Inc. PRODUCT INFORMATION MANUAL C0028 003 Pinnacle OM Manual Rev AB Page 1 of 14 Dantherm, Inc. 110 Corporate Drive, Suite K Spartanburg, SC 29303 Tel # +1 864

More information

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Ion Endeavor Controller Digital Level Control with Alternation Page 1 of 8 General Overview The Ion Endeavor is a pump controller that senses a water level of up to 72", has a configurable water level/pump

More information

CO2 Sensor User and Installation Guide

CO2 Sensor User and Installation Guide CO2 Sensor User and Installation Guide P/N: 110227 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical

More information

Assembly. Host Sub-D Alarm

Assembly. Host Sub-D Alarm HighDensity Power Hub, Generic Interface Features Assembly 4 segments, loadsharing redundancy Output: 22... 24 V/360 ma, Ex ib IIC for intrinsically safe, highpower segments Redundant connection to PROFIBUS

More information

Operating Manual. Gasgard 100 Control System. Order No.: /00. MSAsafety.com

Operating Manual. Gasgard 100 Control System. Order No.: /00. MSAsafety.com Operating Manual Gasgard 100 Control System Order No.: 10153908/00 MSAsafety.com Warning! THIS MANUAL MT BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR ING OR SERVICING

More information

LC2200 Level Controller Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions 4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%

More information

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor Humidity Sensor Temperature/Humidity Sensor ES2-THB CSM ES2-THB_DS_E_3_2 Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control.

More information

Patent Pending invent for New Construction

Patent Pending invent for New Construction Patent Pending invent for New Construction Users Manual 3.0 2 Introduction Your new invent for New Construction manual register is an energy saving and comfort enhancing device. The unit works by replacing

More information

Model PT-05 Model PT-06

Model PT-05 Model PT-06 Model PT-05 Model PT-06 operators handbook Preface Dear User Welcome to the growing group of PT-06 Clam-Press and PT-05 Clam- Press Mini users. The product you have purchased has been carefully designed

More information

Industrial Communications System Page/Party Flush-Mount Subset

Industrial Communications System Page/Party Flush-Mount Subset GAI-TRONICS A HU BBE LL C O MP AN Y Industrial Communications System Page/Party Flush-Mount Subset General Information Product Overview The GAI-Tronics Industrial Communications System (ICS) Page/Party

More information

MN908 No. 282C Replaces 282B LB7013

MN908 No. 282C Replaces 282B LB7013 No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals

More information

Preamplifier Power Supply PPS-02 user's guide

Preamplifier Power Supply PPS-02 user's guide Preamplifier Power Supply PPS-02 user's guide 1 Table of contents 1. Warranty... 3 2. PPS-02 overview... 4 2.1. PPS-02 parameters... 4 2.2. Coding the symbol of the power supply...4 2.3. PPS-02 physical

More information

Direct Current Alarm USER S MANUAL. May No K by Moore Industries-International, Inc.

Direct Current Alarm USER S MANUAL. May No K by Moore Industries-International, Inc. May 2016 Direct Current Alarm USER S MANUAL No. 192-701-00 K 2012 by Moore Industries-International, Inc. Table of Contents Introduction 1 Description 1 Calibration 4 Installation 19 Maintenance 22 48

More information

Installation & Operation Manual

Installation & Operation Manual Humidity & Temperature Sensor 086 Accessories 086_D 08/12 Replaces: New Installation & Operation Manual Introduction The Humidity & Temperature Sensor 086 can be connected to select tekmar thermostats

More information

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified 0232-03J December 13, 2006 FUSE PANEL Technical Practice N215112-NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 2 KLM and 4 GMT fuses in each (30Amps/KLM, 15Amps/GMT).

More information

INSTALLATION MANUAL VISUAL PERFORMANCE RECTANGLE SPEAKERS. Introduction. Box Contents. Speaker Placement. Surround Speakers (5.

INSTALLATION MANUAL VISUAL PERFORMANCE RECTANGLE SPEAKERS. Introduction. Box Contents. Speaker Placement. Surround Speakers (5. INSTALLATION MANUAL VISUAL PERFORMANCE Introduction Thank you for purchasing Sonance Visual Performance Rectangle Speakers. When properly installed your new speakers will give you years of entertainment

More information

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL. Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION...

More information

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions

More information

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction

More information

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL Installation and Operation Manual 2 GG-2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

ALL-WEATHER LANDSCAPE BURIAL SUBWOOFERS Burial Subwoofers: 10 & 12 (250mm & 300mm)

ALL-WEATHER LANDSCAPE BURIAL SUBWOOFERS Burial Subwoofers: 10 & 12 (250mm & 300mm) ALL-WEATHER LANDSCAPE BURIAL SUBWOOFERS Burial Subwoofers: 10 & 12 (250mm & 300mm) CONTENTS 10 Burial Subwoofer: (1) Burial Subwoofer with Direct Burial Cable Attached (2) Silicone-Filled Wire Connectors

More information

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ). SECTION 28 13 00 - ACCESS CONTROL PART I - GENERAL 1.1 SUMMARY A. This specification section describes the furnishing, installation, commissioning, and programming of a complete, turnkey, hardwired Andover

More information

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600 I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d Model code: BORA600 Contact Caple on 0844 8003830 or for spare parts www.4caple.co.uk 1 Y O U R A P P L I A N C E Thank you for buying your

More information

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL GASGUARDIAN 2 3 2-Channel Controller OPERATING & INSTALLATION MANUAL GasGuardian 2 3 Operating and Installation Manual Table of Contents General description.... 3 Installation. 3 Locating the GasGuardian-2..

More information

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access II User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access Part #2139703 Rev. G II Table of Contents Introduction...3 Elevator Overview...4 Description of Features...5-7

More information

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand

More information

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products: Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2

More information

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified 0803-03B April 17, 2008 Noran Tel PANEL Technical Practice N250110-N/0803 5/5 GMT Front Access NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 5 GMT fuses in each (15Amps/GMT position). Polarity

More information

2. All connections are 24 volt AC. Verify all planned connections at TT thermostat connections, before turning on power

2. All connections are 24 volt AC. Verify all planned connections at TT thermostat connections, before turning on power .1. Turn off all power to the boiler at the circuit breaker. This will avoid accidental injury, or short circuits. 2. All connections are 24 volt AC. Verify all planned connections at TT thermostat connections,

More information

OPERATION MANUAL MODEL 805 ACCELEROMETER

OPERATION MANUAL MODEL 805 ACCELEROMETER OPERATION MANUAL MODEL 805 ACCELEROMETER TE CONNECTIVITY SENSORS /// MODEL 805 ACCELEROMETER 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted during a period of one year

More information

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB Introduction Thank you for purchasing a SLS Subwoofer. When properly installed, this subwoofer will provide you with years of outdoor entertainment

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector "The Most Powerful Dust Collector In Its Class... Guaranteed!" IMPORTANT INSTRUCTIONS DO NOT DISCARD I Thank

More information

Installation Guide

Installation Guide Installation Guide 502-018 TOA1 Series Sensor SUPERSEDES: October 22, 2010 EFFECTIVE: November 17, 2010 Plant ID: 001-3966 Table of Contents TOA1 Sensor................................ 2 Features..................................

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL Model TME- * * Balance of model number is determined by customer specifi ed limits and Setbacks. AUTOMATIC SETBACK THERMOSTAT LIGHT SENSING OR CONTACT CLOSURE FOR LOW VOLTAGE

More information

OPERATION MANUAL MODEL & ACCELEROMETER

OPERATION MANUAL MODEL & ACCELEROMETER OPERATION MANUAL MODEL 8011-01 & 8021-01 ACCELEROMETER TE CONNECTIVITY SENSORS///MODEL 8011-01 & 8021-01 ACCELEROMETER 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted

More information

DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL

DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL BUNN HC-1 HC-2 HC-3 DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE:

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS Important Safety Instructions When using this electrical equipment, basic safety precautions should always be followed, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. This appliance must

More information

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified 0226-03K August 13, 2008 FUSE PANEL Technical Practice N250120-N/L9 10/10 GMT NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 10 GMT fuses in each (15Amps/GMT position). Polarity insensitive

More information

LC3000 Level Controller Installation and Maintenance Instructions

LC3000 Level Controller Installation and Maintenance Instructions 4025550/12 IM-P402-36 AB Issue 12 LC3000 Level Controller Installation and Maintenance Instructions 1. General safety information LC3000 NORM ALARM TEST 2. General product information 3. Installation 4.

More information

Viessmann B1HA Boiler Series

Viessmann B1HA Boiler Series User Guide Version 1.0 Installation and Commissioning Guide www.tamashydronic.com Table of Contents Introduction... 3 Components... 4 Operation... 5 Technical Data... 6-7 Wiring... 8-9 Commissioning...

More information

Corrosion Resistant Fluid and Air Handling Systems.

Corrosion Resistant Fluid and Air Handling Systems. Socket Fusion Hand Tool Operation & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Description The Simtech portable socket fusion machines are available in two size ranges ½ -2

More information

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications 70-82-03-48 January 2003 Overview The DirectLine DL424/425 Sensor Modules are part of a family of products developed

More information

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL Andover Corporation 4 Commercial Drive Salem, New Hampshire 03079-2800 Tel: (603) 893-6888 US Toll Free: (888) 893-9992 Fax: (603) 893-6508 Email:

More information

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL 95 Methodist Hill Drive Rochester, NY 14623 Phone: US +1.585.321.5800 Fax: US +1.585.321.5219 www.spectracomcorp.com Part Number 8143-5000-0050

More information

nova extreme retrofit High Output T5 Lighting Kit

nova extreme retrofit High Output T5 Lighting Kit nova extreme retrofit High Output T5 Lighting Kit Instructions for Model Nova Extreme Retrofit Model#1130-1135 Important Safety Instructions... Page 2 Installation Instructions... Page 4 Warranty... Page

More information

Chargebuster Ion Gun Installation, Operation and Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance TECHNICAL BULLETIN TB-6559 Chargebuster Ion Gun Installation, Operation and Maintenance The Chargebuster Ion Gun reduces a static charge of ±1000 V down to ±100 V in less than one second at a distance

More information

CD6102 / CD6102 OC / CD6102-2

CD6102 / CD6102 OC / CD6102-2 PreView Display CD6102 / CD6102 OC / CD6102-2 Operating Manual www.previewradar.com PATENTS Patented under one or more of the following U.S. Patents: 5345471, 5523760, 5457394, 5465094, 5512834, 5521600,

More information

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector CAUTION & SYMBOL DEFINITIONS: CAUTION: Gives detailed description of different situations to avoid or not avoid for the proper operation of the

More information

Ozone + UV Sanitation

Ozone + UV Sanitation Ozone + UV Sanitation Installation Manual 4-2177-01 Rev.C IMPORTANT SAFETY INSTRUCTIONS When installing and operating the DEL Spa Solar Eclipse, basic precautions should always be followed: READ AND FOLLOW

More information