ESD3000IR ESD3000IR. Infrared Gas Detector

Size: px
Start display at page:

Download "ESD3000IR ESD3000IR. Infrared Gas Detector"

Transcription

1 ESD3000IR ESD3000IR Infrared Gas Detector Infrared gas sensor Ex-proof certificate Exd ⅡC T6 Gb Dust Ex-proof certificate Ex td A21 IP66 T80 Site LCD display HART communication Replaceable sensor design With audial & visual alarm and relay output 34

2 ESD3000IR Infrared Gas Detector Specifications Detected gas: combustible gas/ carbon dioxide Detection theory: Infrared Spectroscopy absorption Measure scope: 0~100%LEL (combustible gas)/ 0~5%v/v (carbon dioxide) Accuracy: ±3%LEL (combustible gas)/±3%fs (carbon dioxide) Repeatability: ±2% Response time: T90<20S Electrical Power supply: 24VDC (normal working voltage: 10-30VDC) Power consumption: <2.5W Output signal: 3-wire 4~20mA+HART+relay & visual alarm Structural Main parts material: ADC12 aluminum alloy/316 stainless steel Thread: M20X1.5, 1/2NPT internal thread ( select G3/4 or G1/2 or 3/4NPT) Weight: 2.17kg (aluminum alloy) /4.1 kg(stainless steel) Certificate Ex-proof certificate: Exd ⅡC T6 Gb/Ex td A21 IP66 T80 Fire safety certificate: CCCF Metrological certificate: CMC Standard implemented: GB , GB , GB , GB , GB , GB , GB , JJF Operating condition IP rating: IP66 Temperature: -40 ~70 Humidity: 10~95%RH (Non-condensing) Pressure: 86~106KPa 35

3 Dimension Unit: mm Display Product fault Alarm indicate Density value Gas density unit detected HART communication guide Zeroing indicate 36

4 Mounting bracket Ø 40- Ø Unit: mm Mounting style Horizontal pole Vertical pole Wall type 37

5 Components Visual alarm assembly Audial alarm assembly EMC components Terminal cover assembly Display cover assembly Display assembly Peripheral components Enclosure assembly Sensor assembly Explosion-proof cover Weatherproof cover Commissioning and calibration Controller Detector Pressure relief valve with flow meter Calibration cup Conduit Standard gas cylinder 38

6 Site commissioning Terminal wiring Wiring terminal with relay Wiring terminal 39

7 Electrical wiring Controller 1 V+ 1 V+ Detector 2 S 2 S RL V- V- 3 3 Equipment connected with relay Equipment power supply Equipment J 4 K 5 connection of 3-wire detector with controller (with relay) Flameproof wiring style Flameproof adaptor Cable Cable peeling position Wiring Terminal Take equipment with relay for instance 40

8 Selected cross-sectional area of selected cable and transportation distance is as follows (when connected with ExSaf controller): Cross-sectional Area(mm 2 ) Resistance (ohms per km) Maximum Distance (m) (loop distance) ESD3000IR Gas Detector Type Selection Table Model Product illustration ESD3000IR Gas detector Code Sensor type code H infrared Code Gas type KXXX Combustible gas (see combustible gas list) CO2 Carbon dioxide Code Range LEL 0-100%LEL 5V 0-5%v/v Code Electrical interface M20 M20 12NPT 1/2NPT G34 M20X1.5 rotate to G3/4 G12 M20X1.5 rotate to G1/2 34NPT M20X1.5 rotate to 3/4NPT Code Output signal 3HJS 3-wire 4~20mA+HART+relay+audial and visual alarm Code Enclosure material C12 ADC12 aluminum alloy stainless steel Code Mounting style P Normal mounting style Code System name X ExSAF gas detection system ESD3000IR H K001 LEL G34 3HJS C12 P X (product type selection demonstration) 41

9 ESD3000IR Detectable Combustible Gas List NO. Gas name Formula Corresp. D. Flash point ( ) Combustible limit (V %) LFL UFL Ig. TEMP ( ) MESG (mm) TEMP G. Grade K001 Methane CH T1 IIA K002 Toluene C 6 H 5 CH T1 IIA K003 Methanol CH 3 OH T2 IIA K004 Methyl formate HCOOCH T1 IIA K005 Ethyl formate HCOOCH 2 CH IIA Ethyl methyl K006 Ether CH 3 OCH 2 CH T4 IIB K007 Ethane CH 3 CH T1 IIA K009 Ethanol CH 3 CH 2 OH T2 IIA K010 Ethyl benzene CH 3 CH 2 C 6 H T2 IIA K012 Methyl acetate CH 3 COOCH T1 IIA K013 Ethyl acetate CH 3 COOCH 2 CH T2 IIA K014 N-butyl acetate CH 3 COOCH 2 (CH 2 ) 2 CH T2 IIA K015 Propane CH 3 CH 2 CH T1 IIA K016 Propyl alcohol CH 3 CH 2 CH 2 OH T2 IIB K017 Propylene CH 2 =CHCH T1 IIA K018 Acetone (CH 3 ) 2 CO T1 IIA K019 Butane C 4 H T2 IIA K020 Butanone CH 3 CH 2 COCH T2 IIB K021 Butadiene CH 2 =CHCH=CH T2 IIB K022 Pentane C 5 H < T3 IIA K023 Hexane CH 3 (CH 2 ) 4 CH T3 IIA K024 Heptane C 7 H T3 IIA K025 Octane CH 3 (CH2) 3 CH T3 IIA K026 Nonane CH 3 (CH 2 ) 7 CH T3 IIB K031 Isobutane (CH 3 ) 2 CHCH T1 IIA K032 Isopropanol (CH 3 ) 2 CHOH T2 IIA K033 1-butanol CH 3 (CH 2 ) 2 CH 2 OH T2 IIA K034 Cyclohexane CH 2 (CH 2 ) 4 CH T3 IIA K035 Cyclopentane CH 2 (CH 2 ) 3 CH < T2 IIA K036 Propylene oxide CH 3 CHCH 2 O T2 IIB K037 Ethylene oxide CH 2 CH 2 O 1.52 < T2 IIB K038 Diethyl ether (CH 3 CH 5 ) 2 O T4 IIB K039 Dimethyl ether (CH 3 ) 2 O T3 IIB K040 Xylene C 6 H 4 (CH 3 ) T1 IIA K041 Gasoline C 4 ~C 12 hydrocarbon mixture 0.73 < T3 IIA K042 Jet fuel, kerosene C 9 ~C 16 hydrocarbon mixture 0.8 < T3 IIA 42

ESD3000 ESD200 Combustible / Toxic Gas Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector ESD3000 ESD200 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

ESD500. ESD500 Combustible / Toxic Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector ESD500 ESD500 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring] ULTIMA XIR ULTIMA X 3 ULTIMA XE ULTIMA X Series [ State-of-the-Art Gas Monitoring] ULTIMA X Gas Monitors [ Providing a unique Range of Capabilities] ULTIMA X are state-of-the-art gas monitors for continuous

More information

MERIDIAN UNIVERSAL GAS DETECTOR

MERIDIAN UNIVERSAL GAS DETECTOR MERIDIAN UNIVERSAL GAS DETECTOR MERIDIAN UNIVERSAL GAS DETECTOR The term universal is frequently used in the industry to characterize gas detectors that address both toxic and combustible gases, but it

More information

Installation and Wiring 1.

Installation and Wiring 1. Installation and Wiring 1. Please read the Security Notifications in detail firstly. 2. The gas detector might install on wall or steel plate, please refer following drawing to make marking then drill

More information

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS TECHNICAL NOTE s for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS The DataFID and MicroFID II are portable flame ionization detectors designed to monitor volatile organic

More information

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection 3M TM Meridian Description Designed with safety and reliability in mind, the Meridian universal gas detector is suitable for use in SIL-2 and SIL-3-rated systems under the IEC 61508 standards, certified

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation

More information

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features. Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb

More information

Dräger Polytron SE Ex Fixed Gas Detector

Dräger Polytron SE Ex Fixed Gas Detector Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement

More information

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring

More information

Dräger PEX 3000 Flammable Gas Detection

Dräger PEX 3000 Flammable Gas Detection Dräger PEX 3000 Flammable Gas Detection The transmitter Dräger PEX 3000 detects flammable gases and vapors in concentrations below their Lower Explosion Limit Its DD-sensor provides a very long-term stable

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

LFL Monitoring. MEGTEC Systems

LFL Monitoring. MEGTEC Systems LFL Monitoring MEGTEC Systems Flammability For each volatile flammable substance there is a concentration in air (usually expressed as % of volume, known as Lower Flammable Limit LFL). Below LFL concentration

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

Installation & User Manual

Installation & User Manual & INFRARED & CATALITIC DETECTORS Installation & User Manual ATEX IP65 Certificate nº FS82426 2013 DURAN ELECTRONICA S.L. - All rights reserved www.duranelectronica.com TABLE OF CONTENTS pages 1. DIREX.

More information

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions Because every life has a purpose PrimaX IR Gas Transmitter Every feature of the SIL 2 engineered PrimaX IR Gas Transmitter

More information

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles

More information

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance 4P-90 CiTipeL Combustible Gas Sensor Part Number: PM143-000 Performance

More information

GAS PLUS ALARM SYSTEM

GAS PLUS ALARM SYSTEM GAS PLUS -IR SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER GAS PLUS -IR TRANSMITTER SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER The Scott Gas Plus -IR Model 4688 IR Gas

More information

VSD AND SS DRIVING ATEX MOTORS February 2014

VSD AND SS DRIVING ATEX MOTORS February 2014 VSD AND SS DRIVING ATEX MOTORS February 2014 1 Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions Introduction to ATEX EU territory define the use of electrical equipment

More information

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate OPERATION MANUAL SERIES 873 UL Listed for Class I, Group C and D Hazardous Locations Model # Voltage Description SP87325 120 9.13 X 9.13 (23.2

More information

Explosion protection Marijan Gorše, dipl. ing.

Explosion protection Marijan Gorše, dipl. ing. Explosion protection Marijan Gorše, dipl. ing. 1/18 Flammable Gas Atmosphere We Can Control Them Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion

More information

Combustible Gas Detection and Control System

Combustible Gas Detection and Control System Combustible Gas Detection and Control System DESCRIPTION Gas monitor with built-in combustible gas sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature or humidity

More information

Explosion-proof Duct Heaters

Explosion-proof Duct Heaters Safety INDEECO explosion-proof ULTRA-SAFE and EP2 duct heaters are Factory Mutual (FM) and CSA Approved. The ULTRA-SAFE duct heater has the only standard product offering and features the industry s lowest

More information

Thank You for Attending Today s Webinar:

Thank You for Attending Today s Webinar: Detect, Measure, Analyze. Thank You for Attending Today s Webinar: Best Practices in Maintaining Gas Detection Systems Featured Speaker John Greivell VP Operations RAECO-LIC LLC johng@raeco.com Featured

More information

Electron Microscopy Sciences

Electron Microscopy Sciences Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT. 72341-10 Explosion Proof Hot Plate Stirrer Model SF87325 P.O. Box 550 s1560 Industry Road s Hatfield PA 19440 1 Safety Symbols Used in this Instruction

More information

1. GENERAL TECHNICAL INFORMATION

1. GENERAL TECHNICAL INFORMATION 1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.

More information

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens Scott Meridian Fixed Gas Detector This section introduces the Meridian Universal Fixed Gas Detector from Scott Safety, a Tyco International company and a world leader in the design and manufacture of industrial

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Operation and Maintenance Manual GDS-IR Infrared Sensor for Combustible Gases & CO 2 GDS Corp. 2513 Hwy 646 Santa Fe, Texas 77510 409-927-2980 409-927-4180 (Fax) www.gdscorp.com CAUTION: FOR SAFETY REASONS

More information

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres] II 2G EEx ia d ATEX 100 D MT IIC T6 99 ATEX G 001 x Series [ Versatility in Explosive Atmospheres] [ The flexible solution for all your needs] After accidents with hazardous material the will provide reliable

More information

OLC(T) 100 FIXED GAS DETECTOR

OLC(T) 100 FIXED GAS DETECTOR Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The

More information

THE BELGIAN PIONEER IN GAS DETECTION

THE BELGIAN PIONEER IN GAS DETECTION DAX 3F Gas detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION Copyright 2016 by DALEMANS s.a. Revision V1R6 07/2016 Any reproduction, whether partial or entire, made of this document, by

More information

Gas detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION

Gas detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION Gas detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION Copyright 2016 by DALEMANS s.a. Revision V1R2 07/2016 Any reproduction, whether partial or entire, made of this document, by whatever

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY FEATURES TXGARD & FLAMGARD PLUS Digital display with flexible output options Wide range of long life sensors Non-intrusive one-man

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Certifications The Fixed Gas Detection People The OLC/OLCT CT range of fixed ddetectors

More information

SEC Millenium Hydrocarbon Gas Detector

SEC Millenium Hydrocarbon Gas Detector SEC Millenium Hydrocarbon Gas Detector Instruction and Operation Manual Sensor Electronics Corporation 12730 Creek View Avenue Savage, Minnesota 55378 USA (952) 938-9486 Fax (952) 938-9617 Email: sales@sensorelectronic.com

More information

CC28. Operation Manual. Transmitter for flammable gases and vapours

CC28. Operation Manual. Transmitter for flammable gases and vapours Operation Manual CC28 Transmitter for flammable gases and vapours GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63 13

More information

Explosion Proof Speaker, Ringer & Speaker/Ringer

Explosion Proof Speaker, Ringer & Speaker/Ringer Explosion Proof Speaker, Ringer & Speaker/Ringer Models SR40 and SR60 Installation & Operation P004562 Rev. G 150831 8/31/2015 11:06 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com

More information

FACT SHEET Program: Lab Fire Safety

FACT SHEET Program: Lab Fire Safety REFRIGERATION/FREEZING OF FLAMMABLE LIQUIDS Fires and explosions can and do occur in either general-purpose laboratory or ordinary domestic refrigerators or freezers when these types of appliances are

More information

Operation Manual Infrared Hydrocarbon Gas Detector SGOES

Operation Manual Infrared Hydrocarbon Gas Detector SGOES Operation Manual Infrared Hydrocarbon Gas Detector SGOES 80016-001 Information and technical data disclosed in this document may be used and distributed only for the purposes and to the extent specifically

More information

THE BELGIAN PIONEER IN GAS DETECTION

THE BELGIAN PIONEER IN GAS DETECTION DAT 420 Gas or oxygen detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION Copyright 2016 by DALEMANS s.a. Revision V1R7 07/2016 Any reproduction, whether partial or entire, made of this document,

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66. Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed

More information

Fire Alarm System Accessories

Fire Alarm System Accessories Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS FEATURES Extremely wide range of sensors Easy installation and maintenance Low cost of ownership Replacement of sensors are simple Rugged and reliable

More information

3M Oldham OLCT 100. Description. Fixed Gas Detector

3M Oldham OLCT 100. Description. Fixed Gas Detector Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,

More information

GMA101. Operation Manual. Worldwide Supplier of Gas Detection Solutions

GMA101. Operation Manual. Worldwide Supplier of Gas Detection Solutions Worldwide Supplier of Gas Detection Solutions GfG Instrumentation, Inc. 119 Oak Valley Drive Ann Arbor, Mi. Phone: (7) 769-057 Fax: (7) 769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA101

More information

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases DETECTION DE GAZ FIXE OLCT Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Better detection. Better

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-f-profit institution. We develop, apply and disseminate research- and technologically-based knowledge f the Danish

More information

PREMIER PLATINUM INFRARED GAS SENSOR

PREMIER PLATINUM INFRARED GAS SENSOR PREMIER PLATINUM INFRARED GAS SENSOR LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0150

More information

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring] ULTIMA XIR ULTIMA X 3 ULTIMA XE ULTIMA X Series [ State-of-the-Art Gas Monitoring] ULTIMA X Gas Monitors [ Providing a unique Range of Capabilities] ULTIMA X are state-of-the-art gas monitors for continuous

More information

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW Any flashlight that is intended to be used in a hazardous location must be tested and approved for that use because it

More information

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : E

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : E TECHNICAL MANUAL OLCT IR INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2 Part Number : NPOIRGB Revision : E The Fixed Gas Detection Experts 2 User Manuel GAS DETECTION Thank you for purchasing an OLDHAM

More information

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS For a print friendly page click here INTRODUCTION Hazardous areas are those in which there exists a risk of explosion

More information

Explosion-protected actuator Page 259 of 292

Explosion-protected actuator Page 259 of 292 Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.

More information

Model FP-424C ma Combustible Gas Sensor (0-100% LEL) Operator s Installation & Instruction Manual. May 18, 2010 Document #2243T Version 3.

Model FP-424C ma Combustible Gas Sensor (0-100% LEL) Operator s Installation & Instruction Manual. May 18, 2010 Document #2243T Version 3. detcon inc. Model FP-424C 4-20 ma Combustible Gas Sensor (0-100% LEL) Operator s Installation & Instruction Manual May 18, 2010 Document #2243T Version 3.8 CAUTION: FOR SAFETY REASONS THIS EQUIPMENT MUST

More information

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety GDS Corp gas monitors, controllers and sensors satisfy today s needs for safety and reliability in critical gas detection

More information

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white . TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8

More information

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62. 637 PHOTO PHOTO Flameproof Type Curtain Type 4 General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Sensor selection guide... P.497~ General precautions... P.1458~ Conforming

More information

ST Explosion Protection GAS DETECTION SYSTEMS

ST Explosion Protection GAS DETECTION SYSTEMS ST-6057-2004 Explosion Protection GAS DETECTION SYSTEMS 02 Explosion hazards due to flammable gases and vapours THE DANGER OF EXPLOSION IS LURKING EVERYWHERE Detecting flammable gases and vapours before

More information

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global 597 Flameproof Type Light Curtain Type 4 General terms and conditions... F-3 Related Information guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P.1595 PHOTO PHOTO Certified

More information

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR 70086 The information in this doucment is applicable to sensors built in September, 2008 or later (Firmware 3.0) The information and technical

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ] ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical

More information

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Model C12-17 Combustible Gas Transmitter Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New

More information

SBS-H2 Hydrogen Gas Detector Kit

SBS-H2 Hydrogen Gas Detector Kit SBS-H2 Hydrogen Gas Detector Kit For battery charging rooms and other areas where hydrogen gas may be present INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Protects Life, Property and Profits Electrical

More information

Dräger Flame 2500 Flame Detection

Dräger Flame 2500 Flame Detection Dräger Flame 2500 Flame Detection Working in areas with combustible gases, vapours or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres Quick Introduction to: DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-fprofit institution. We develop, apply and disseminate research- and technologically-based

More information

Beamex Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper.  Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

User Manual. PolyGard AT-3300 V3. Transmitter for Combustible Gases. Serial No. ET April 2009

User Manual. PolyGard AT-3300 V3. Transmitter for Combustible Gases. Serial No. ET April 2009 PolyGard AT-3300 V3 Transmitter for Combustible Gases Serial No. ET03-002 User Manual April 2009 January 04, 2016 Revision Specifications subject to change without notice. USA 151203 Page 2 of 14 1 Intended

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

Detcon MicroSafe. FP-624HT Combustible Gas Sensor (0-100% LEL) Specialized Version For High Temperature Operation of Sensor Head

Detcon MicroSafe. FP-624HT Combustible Gas Sensor (0-100% LEL) Specialized Version For High Temperature Operation of Sensor Head detcon inc. Detcon MicroSafe FP-624HT Combustible Gas Sensor (0-100% LEL) Specialized Version For High Temperature Operation of Sensor Head Operator s Installation & Instruction Manual May 18, 2010 Document

More information

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : G.

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : G. TECHNICAL MANUAL OLCT IR INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2 Part Number : NPOIRGB Revision : G.0 The Fixed Gas Detection Experts 1 Copyright April 2016 by Oldham S.A.S. All rights reserved.

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T P R O D U C T D T S H E E T www.internationalgasdetectors.com Transmitters Control Systems Sensors ccessories Series Gas Detectors 4-0m Device and 3 Wire ddressable Versions Compact Size EExd Certified

More information

Hydrocarbon Gas Detector

Hydrocarbon Gas Detector SEC Millenium Hydrocarbon Gas Detector Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 Email: sales@sensorelectronic.com

More information

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0149 LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** SIL1 MSH2-LS/HC/CO2 MSH2ia-LS/HC/CO2

More information

Fire Alarm System Accessories

Fire Alarm System Accessories UL, ULC Approved* Fire Alarm System Accessories Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer isolated barrier

More information

Dräger Flame 2100 Flame Detection

Dräger Flame 2100 Flame Detection Dräger Flame 2100 Flame Detection Working in areas with combustible gases, vapors, or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection Dräger Flame 2500 (IR3) Flame Detection With its triple IR sensor The Dräger Flame 2500 detects hydrocarbonbased fires even over greater distances. Moreover, it offers a high reliability against false

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

Flameproof Type Light Curtain Type 4

Flameproof Type Light Curtain Type 4 545 PHOTO PHOTO Flameproof Type Curtain Type 4 Sensor selection guide...p.11~ / P.479~ General terms and conditions... P.1 SF4-AH... P.569 ~ Glossary of terms / General precautions... P.983 ~ / P.986 ~

More information

GMA 41. Operation Manual. Worldwide Supplier of Gas Detection Solutions

GMA 41. Operation Manual. Worldwide Supplier of Gas Detection Solutions Worldwide upplier of Gas Detection olutions GfG Instrumentation 1194 Oak Valley Drive, uite 20 Ann Arbor, MI 48108 800-959-0329 tel 734-769-1888 fax Email: info@gfg-inc.com GMA 41 Operation Manual Page

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Operation and Maintenance Manual GDS-48 Remote Bridge Sensor for Combustible Gases AUTHORIZED DISTRIBUTOR: GasDetectorsUSA.com - Houston, Texas USA sales@gasdetectorsusa.com - 832-615-3588 CAUTION: FOR

More information

ATEX Safety Switches. More than safety.

ATEX Safety Switches. More than safety. ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from

More information

Hazardous area descriptions

Hazardous area descriptions Hazardous area descriptions National Electrical Code (NEC) 500 Traditional standards used in North America. Example: Class I, Div 1, Group B, C, D, T4 Permitted Class Permitted Division Permitted Group

More information

GMA44 Operation Manual

GMA44 Operation Manual Worldwide upplier of Gas Detection olutions GfG Instrumentation 1194 Oak Valley Drive Phone: 734-769-0573 Fax: 734-769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA44 Operation Manual Content

More information

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual GG-LEL2 COMBUSTIBLE GAS SENSOR Installation and Operation Manual 2 GG-LEL2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

INSTRUCTION MANUAL Detcon Model FP-524D-HRT

INSTRUCTION MANUAL Detcon Model FP-524D-HRT INSTRUCTION MANUAL Detcon Model FP-524D-HRT PGM 1 HOUSTON, TEXAS TM MicroSafe LEL Gas Sensor ALM ALM FLT 1 2 CAL PGM 2 FP-524D-HRT Combustible Gas Sensor (0 100% LEL) with HRT Bridge DETCON, Inc. 4055

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

SP-220. Features. Combustible handheld gas leakage detector

SP-220. Features. Combustible handheld gas leakage detector SP-220 Combustible handheld gas leakage detector The SP-220 gas leakage detector is a simple to operate unit with high sensitivity to a variety of gases. The SC version (SP-220SC) is able to detect super-toxic,

More information

Portable Combustible Gas Detector GP-1000 Operating Manual (PT0-120)

Portable Combustible Gas Detector GP-1000 Operating Manual (PT0-120) PT0E-1200 Portable Combustible Gas Detector GP-1000 Operating Manual (PT0-120) Safety information The Combustible Gas Monitor Model GP-1000 is a gas monitor designed to provide continuous monitoring of

More information

700 IR Series. Instruction Manual. Infrared Gas Detector for Combustible and CO 2 gases OLCT 700 OLCT 710. The Fixed Gas Detection Experts

700 IR Series. Instruction Manual. Infrared Gas Detector for Combustible and CO 2 gases OLCT 700 OLCT 710. The Fixed Gas Detection Experts Instruction Manual 700 IR Series Infrared Gas Detector for Combustible and CO 2 gases OLCT 700 OLCT 710 Part Number: NP700IRIMEN Revision: B.1 The Fixed Gas Detection Experts Copyright Jan 2016 by Oldham

More information

INSTRUCTION MANUAL Detcon Model FP-524D

INSTRUCTION MANUAL Detcon Model FP-524D INSTRUCTION MANUAL Detcon PGM 1 MODEL HOUSTON, TEXAS FP-524D MicroSafe TM LEL Gas Sensor ALM ALM FLT 1 2 CAL PGM 2 FP-524D Combustible Gas Sensor (0 100% LEL) DETCON, Inc. 4055 Technology Forest Blvd,

More information

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik Jl. Pluit Karang Ayu Blok B1 Apartment Green Bay Pluit Tower E Lt. 3, Suite AM 14450, North Jakarta, Indonesia Telephone: +6289610416092 Website: www.vgt.co.id

More information

THERMAL ELECTRIC ELEMENTS

THERMAL ELECTRIC ELEMENTS certified hazardous area heaters VERSION 1.1 THERMAL ELECTRIC ELEMENTS AUSTRALIA THE SPECIALISTS IN CUSTOM HEATING about tee Thermal Electric Elements was established in 1972 as a father and son operation

More information

Explosion Proof Speaker, Ringer & Speaker/Ringer

Explosion Proof Speaker, Ringer & Speaker/Ringer Explosion Proof Speaker, Ringer & Speaker/Ringer Models SR40 and SR60 Installation & Operation P004562 Rev. H 180430 4/30/2018 12:24 PM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or