EasyTronic III MANUAL SERVICE

Size: px
Start display at page:

Download "EasyTronic III MANUAL SERVICE"

Transcription

1 rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard RS485 2 Digital inputs 14 Input for phase sequence 1 a 5 Vac Temp. analog inputs 2 (10 bit) LCD contrast regulation 20 levels Maximum life 50,000 hours Analog input 4-20mA 1 (12 bit) Analog output 4-20mA 1 (10 bit) Clock calendar with lithium battery CR2032. Internal alarm buzzer. Maximum distance of base from display: 2 meters, through Ethernet cable.

2 START PAGE, remains on screen for 3 seconds after the central is started. Easy Controll III Ver.0.0 data Easy Controll III NORMAL OPERATION SCREEN ----Screw temp.: 065 C 06.5Bar 000% STATUS=OFF Ora data Start screen: 1st line: use arrow keys and to display the following information (after 25 seconds without typing anything the display will automatically show screw temperature). 1. intern. temp.: indicates the temperature inside the electro-mechanical plant air temp.: indicates the temperature at the air outlet screw temp.: indicates the temperature of the screws total hours: indicates the total number of the engine s working hours 5. load hours: indicates the number of hours the compressor worked in a load cycle idling hours: indicates the number of hours the compressor worked in a IDLING cycle. 7. mainten. hours.: indicates the remaining number of hours until the next maintenance intervention. A negative number indicates the hours during which the machine has worked without maintenance. 8. air filter hours: indicates the number of hours left before the air filter has to be replaced. 9. bear. lubr.: indicates the number of hours left before bearings have to be lubricated. 10. oil filter hours: indicates the number of hours left before the oil filter has to be replaced. 11. oil change hours: indicates the number of hours left before the oil has to be changed. 12. Start/hours: indicates how many times the motor has started in the past hour. If an inverter is present, together with a communication cable with the inverter connected: 13. inverter temperature: indicates the temperature of the inverter. 14. Inverter frequency.: indicates the frequency at which the inverter is working. 2nd line: Pressure present at motor speed in %. If an inverter is present, together with a communication cable with the inverter connected, % inverter load. 3rd line: Machine status: 1. STATUS=IDLING, the motor is on but the load electro-valve is disabled. 2. STATUS=LOADED, the motor is on and the load electro-valve is enabled. 3. STATUS=STAND-BY, active status, but the motor is off. 4. STATUS=REMOTE-OFF, waiting for the remote start-up command. 5. STATUS=OFF, machine is being supplied but its functioning is disabled. 6. STATUS= REMO.PRESS. OFF, the machine is still, waiting for remote pressure. 4th line. Time and Date. If there is a programmed start-up a blinking clock will be displayed after the date. POSSIBLE ALARMS In case of alarm, the type of alarm is displayed on the first line. If there is more than one alarm present it is possible to scroll up and down the list of alarms by using and. To move to normal display during an alarm, use the right arrow key. To silence the alarms, press Reset. To cancel the alarm, keep Reset pressed for at least 2 seconds. All alarms that are no longer active will be deleted. The alarm of incorrect rotation direction can only be cancelled by cutting off power supply to the machine. Pag 2/12

3 List of alarms: 1. rot. dir. err.: In case of an incorrect phase sequence the central will display rotation direction error and the ALARM LED will light up. This alarm blocks the compressor. To restore function, restore the phase sequence. ATTENTION: This alarm can only be reset by cutting off power supply to the machine. 2. air temp. sens. faulty: This is controlled by the presence of the temperature sensor (open probe or short-circuit). The displayed message is Temperature sensor faulty. This alarm blocks the compressor. To restore function, check the probe and press Reset. 3. screw temp. sens. faulty: This is controlled by the presence of the temperature sensor (open probe or short-circuit). The displayed message is Temperature sensor faulty. This alarm blocks the compressor. To restore function, check the probe and press Reset. 4. max. oil temp.: When the oil reaches its maximum temperature the alarm max. oil temp. is displayed. This alarm blocks the compressor. To start up the compressor again you must wait until the temperature goes back below the programmed value and then press Reset. 5. min. oil temp.: When the oil reaches its minimum temperature the alarm min. oil temp. is displayed. This alarm blocks the compressor. To start up the compressor again you must wait until the temperature goes back up above the programmed value and then press Reset. 6. oil pre temp.: When the oil reaches its pre-alarm temperature the alarm oil pre temp. is displayed. This alarm does not block the compressor. Press Reset to silence the alarm. 7. motor thermal: This alarm is given when the motor thermal intervenes. This alarm blocks the compressor. To silence the alarm, check its cause then press Reset. 8. emergency pushbutton: This alarm means the emergency mushroom button which blocks the compressor has been pressed. To silence the alarm, restore the emergency button to its original position, then press Reset. 9. air filter: This alarm does not block the compressor. To silence the alarm, press Reset. 10. maintenance: This alarm warns the user that the machine requires an ordinary maintenance intervention. This alarm can only be silenced by the service centre which has carried out the maintenance operation; the counter will be reset to the desired value. 11. max. press. al.: This alarm is displayed when the maximum set pressure is exceeded. This alarm blocks the compressor. To silence the alarm, restore the correct pressure, then press Reset. 12. press. sens. broken: This alarm is displayed when the pressure sensor connected to the 4-20 ma input is not working correctly. This alarm blocks the compressor. To silence the alarm, restore the normal status of the pressure sensor, then press Reset. Pag 3/12

4 13. commun. error: This alarm is displayed when communication between the central and the display is lost. This alarm blocks the compressor. Check connections. 14. inverter error: This alarm is enabled when the inverter is active. This alarm blocks the compressor. Check the inverter. 15. screw mot. therm.: This alarm is displayed when the screw motor thermal intervenes. This alarm blocks the compressor. To silence the alarm, check its cause, then press Reset. 16. fan mot. therm.: This alarm is displayed when the fan motor thermal intervenes. This alarm blocks the compressor. To silence the alarm, check its cause, then press Reset. 17. remote press. error: This alarm does not interrupt the compressor. It warns the operator that for some reason the external remote pressure control has not intervened. If the remote pressure parameter is at ON, the alarm cannot be reset until the correct sequence of remote pressure control is restored. CONTRAST REGULATION While the machine is off (status=off), press and at the same time. The first line of the display will show the level of contrast. Contrast can be regulated from 1 (darker) to 20 (lighter) by using keys and. Press OK to confirm. The value is automatically saved in the memory. Pag 4/12

5 PARAMETERS PARAMETER MIN MAX DEF ID Unit of measur. HOURS OF GENERAL MAINTENANCE Hours HOURS OF AIR FILTER REPLACEMENT Hours OIL FILTER HOURS Hours OIL CHANGE HOURS Hours BEARING LUBRICATION HOURS Hours IDLING HOURS Hours TOTAL HOURS Hours PRE-ALARM TEMPERATURE C MAXIMUM TEMPERATURE C MINIMUM TEMPERATURE C FAN TEMPERATURE C IDLING OPERATION TIME sec STOP IDLING TIME AUTOMATIC START NO - INTERNAL PHASE SEQUENCE NO - LANGUAGE ITA - ENABLE RS485 YES - SET DATE AND TIME PSI/BAR BAR - WORKING PRESSURE 0.0 Max Pres 10.0 BAR WORKING DELTA BAR MAXIMUM PRESSURE 0.0 PreAll 0.5Bar 11.0 BAR MAXIMUM ALARM PRESSURE BAR REMOTE PRESSURE NO - START PROGRAM OFF - X01 DIGITAL INPUTS 1-8 Bit X07 DIGITAL INPUTS 1-6 Bit MOTOR THERMALS SEPARATED NO - TEMPERATURE UNIT OF MEASUREMENT C - MAXIMUM START UP/HOURS INVERTER YES - If the inverter is enabled: MINIMUM WORKING % % LOAD DELAY sec INVERTER INTEGRATIVE MAXIMUM FREQUENCY Hz ACCELERATION TIME sec DECELERATION TIME 000, sec S ACCEL. CURVE sec NOMINAL FREQUENCY Hz BOOST AT START UP % MAXIMUM VOLTAGE 0:max.100%v/ f SWITCH FREQUENCY 2 KHz ANALOG COMMAND 4-20 ma Pag 5/12

6 OPERATION Standard switch-on: Press (I). If there are no active alarms the switch-on cycle will start. a) Wait for switch-on: The display will show STAND-BY and the central will wait until the following conditions are present before it starts the compressor: 1) If the machine was previously spent the central must wait for 15 seconds before it starts the compressor. 2) The central must wait until the pressure goes below the value set at IDLING before it starts the compressor. b) Compressor start-up: the line and star remote control switch is switched and the display will show IDLING. c) Normal operating conditions: After 6 seconds the passage from star to triangle takes place. The display still shows IDLING. After the number of seconds programmed in the Delay Load parameter, if the remote control switch so requests the load electro-valve is excited and the display will show LOAD. Standard switch-off: Press OFF to start the switch-off procedure. a) The enabling of the load electro-valve is switched off and the IDLING cycle starts. The display will flash IDLING. When the IDLING Stop cycle ends the compressor will switch off and the display will show STATUS=OFF. Remote switch-on: The compressor can be remotely switched on by using the Remote Control Digital Input. Press (I): if there are no alarms the remote control will start. From this moment on the Remote Control Digital Input will switch the machine on and off. Buttons (I) and (0) have an upper hand over the Remote Control Digital Input. Switch-on procedure from remote pressure: When the remote pressure control is enabled through the menu, the Remote Pressure Digital Input is enabled as well. In this configuration the central will control the remote input as an external pressure gauge, and will also make sure that the gauge functions within the range of preset values (set loaded, set IDLING or working pressure and delta in case of inverter). If the Set pressure is exceeded due to an anomaly of remote pressure control, the central will take over the compressor cycle and force it to work with internally set values, signalling the alarm message Remote press. err. If the remote intervenes before the set IDLING of the central, pressure control is again entrusted to the remote pressure input (at this point the alarm can be reset). Inverter Minimum Protection: If the compressor with inverter remains in the load phase for the minimum % of load for longer than the IDLING time, it will automatically switch to IDLING, to limit working time to the minimum %. Pag 6/12

7 PARAMETER SET UP By pressing OK the machine will stop (Status=OFF) and you will be sent to the parameter set up menu: 0) ID: (service code): Selects the central ID. More than one ID can be selected in case there are more than one machine connected to the same RS485 line. 1) Maintenance (service code): Use keys and to scroll through the 7 possible values. Use keys and to change these values. The counter with a sign indicates the number of hours since maintenance expiry. 1. General Maint.: hours left until general maintenance. When the counter reaches 0 the central goes in Maintenance alarm. 2. Air filter change: hours left until next air filter change 3. Oil filter change: hours left until next oil filter change 4. Oil change: hours left until next oil change 5. Bearing lubric.: hours left until next bearing lubrication 6. IDLING hours: hours of IDLING operation 7. Total hours: total working hours If parameters IDLING hours or Total hours are changed, when leaving the menu the system will require the factory password as confirmation. 2) Alarm log: You can scroll through the last 100 alarm messages, with time, date and screw temperature. To delete the log press and at the same time while in the menu and type in the factory password. 3) Pre-alarm temperature: this value, not changeable, defines the temperature delta, expressed in C, from the maximum alarm temperature. This value can be set from 1 to 20. For instance, if maximum temperature is 120 C and delta is 10 C, the maximum temperature pre-alarm will be displayed at 110 C. 4) Maximum temperature this value, not changeable, defines the Maximum Allowed Temperature. Regulation range goes from 0 to 150 C. 5) Minimum temperature this value, not changeable, defines the Minimum Allowed Temperature. Regulation range goes from 0 to 14 C. 6) Fan temperature (service password): This menu contains the temperature which activates the fan. Regulation range goes from 0 to 150 C. The fan will start when the preset temperature is reached. The fixed hysteresis is 10 C. 7) IDLING time (service password): From this menu you can intervene to alter the machine s IDLING cycle time. Regulation range goes from 60 to 900 seconds, with 5-second steps. 8) Stop IDLING time (service password): From this menu you can intervene to alter the machine s IDLING cycle time before it goes into OFF. Regulation range goes from 30 to 250 seconds, with 5-second steps. 9) Automatic Start (service password): This parameter enables Automatic Stop. When activated, the compressor will start automatically even after a power failure. The initial start must be activated by pressing (I) on the push button panel. For safety reasons its use is absolutely not advisable. 10) Int. phase sequence (service password): This parameter enables the internal phase sequence control, or disables it by activating the phase sequence input on the terminal. 11) Language (free): This parameter changes the language of the menu. 12) Enable RS485 (free): This parameter enables transmission through RS485, and automatically disables transmission through RS232. Pag 7/12

8 13) Set time and date (free): Set date and time. If the battery is low the firmware date is automatically used. If the picture of a battery shows up right after the time, replace the CR2032 battery and set the correct time. 14) PSI/BAR (free): Selects one of these units of measurement for pressure. 15) This parameter is subject to the presence of the inverter. Functioning with inverter: Working pressure (free): In this parameter it is possible to set the working pressure at which the compressor will stop. Functioning without inverter: Set IDLING (free): In this parameter it is possible to set the working pressure at which the compressor will stop. 16) This parameter is subject to the presence of the inverter. Functioning with inverter: Working Delta (free): This parameter becomes the working delta, i.e., it indicates the pressure range at which the compressor must work. For instance, if set at 1.0 bar and if working pressure is 9.0 bar, this means the compressor will switch off at 9.5 bar and switch on again at 8.5 bar. Functioning without inverter: Set load (free): In this parameter it is possible to set the working pressure at which the compressor will start. 17) Maximum pressure (service password): This parameter defines the maximum possible pressure value from menu 14; it therefore limits the maximum pressure the compressor can achieve. 18) Maximum alarm pressure this value, not changeable, defines the maximum pressure value at which the central goes in alarm and blocks the machine. 19) Remote pressure (service password): When this parameter is enabled, the Remote Pressure Input is enabled as well, so that pressure control is demanded to the external pressure sensor connected to this input. In case of malfunctioning of the external sensor, the internal sensor is enabled, with our without inverter. 20) Start-up program (service password): There are 5 programs available (0-4). Use keys and to select the desired program. Press OK to alter it. Select the start time, the stop time and the day of the week in which it must be active. An X indicates that the preset day is active. To disable the program, insert identical start and stop hours. Press OK to confirm. 21) X1 Progr. NC-NO (service password): It is possible to invert the logic of the inputs of terminal X1: position the cursor with arrows and on the input to be altered and use arrows and to modify it. Press OK to confirm. 22) X7 Progr. NC-NO (service password): It is possible to invert the logic of the inputs of terminal X7: position the cursor with arrows and on the input to be altered and use arrows and to modify it. Press OK to confirm. 23) Separate Mot. Therm. (service password): If this parameter is ON the motor thermals of the screw motor and of the fan are separated in two inputs. 24) Temp. unit of measur.: (free) : Use arrows and to choose from degrees Celsius or Fahrenheit. 25) Maximum start/hours (service password): From this parameter you can select the maximum number of starts in a period of 1 hour. If this limit is exceeded the compressor will continue with a IDLING or load cycle according to need, and will return to stand-by when the time of the first start is reached. 26) INVERTER (service password): Enables the inverter. 27) Minimum working % (service password): Indicates the minimum percentage at which the inverter must work. The maximum value is always 100%. 28) Load delay (service password): Indicates the delay, in seconds, before the load electro-valve is enabled after the screw motor has reached its normal working conditions. Pag 8/12

9 29) Inverter integrative (service password): This parameter alters the time constant of the integrative part of the calculation for the Inverter percentage. 30) Inverter parameters (service password): Inverter parameters with KEB protocol: 1. Maximum frequency 2. Acceleration time 3. Deceleration time 4. S acceleration curve 5. Nominal frequency 6. Boost at start-up 7. Maximum tension 8. Switch frequency 9. Analog command Pag 9/12

10 EasyTronic III CONNECTION X03 X10 X07 X02 X X X09 RS485 Progr. Con. Display X06 CN1 CN2 RS232 CN3 1) Connector X8 outputs. Relay Terminal Function Relay No Star Relay No Line Relay No Triangle Relay No Load electro-valve Relay No Alarm Relay No Fan 2) Analog inputs X02 Input Terminal Function Positive +20 Vdc for pressure Transducer 4/20 ma 2 Input 4/20mA Pressure Transducer Temp. 1 3 Air temperature probe input Temp. 2 4 Screw temperature probe input Temp. 3 5 Fixture for further analog input (10bit) Mass 6 Common mass for temperature sensors Pag 10/12

11 3) Analog digital inputs X07 Input Terminal Function Analog 1 Fixture for further analog input (10bit) Dig. 1 2 INVERTER error Dig. 2 3 Fan motor thermal Dig. 3 4 Remote Pressure Digital Input Dig. 4 5 Digital Input Dig. 5 6 Digital Input Dig. 6 7 Digital Input Mass 8 Common mass for digital and analog inputs 4) Phase control input X10 Input Terminal Function GND 1 Earth connection 5 Vac 2 Input 5 Vac for Phase control N.C. 3 Not connected 5) General power supply input X03 Input Terminal Function 0 Vac 1 Input 0 Vac for power supply 24 Vac 2 Input 24 Vac for power supply 6) Digital inputs X01 Input Terminal Function Mass 1 Common mass for digital inputs Dig. 1 2 Emergency Digital Input Dig. 2 3 Oil Filter Digital Input Dig. 3 4 Air Filter Digital Input Dig. 4 5 Oil Mist Eliminator Digital Input Dig. 5 6 External Phase Sequence Digital Input Dig. 6 7 Minimum Pressure Gauge Digital Input Dig. 7 8 Remote Control Digital Input Dig. 8 9 Motor Thermal Digital Input* *: if both motor thermals are enabled, this will become the thermal of the screw motor. 7) Analog output 4/20 ma X09 Output Terminal Function +20 Vdc 1 Positive +20 Vdc for output 4/20 ma Inverter. N.C. 2 Not connected 4/20mA 3 Output 4/20mA Inverter N.C. 4 Not connected Pag 11/12

12 8) RS485 X06 Rs485 Terminal Function A 1 Channel A Rs485 B 2 Channel B Rs485 9) 6-way plug, CN1 programming 10) 8-way plug, communication through display board CN2 11) Interface RS232 CN3 Pag 12/12

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL Prg Sel line alarm on on/off alarm enter Clear EMIpro MICROPROCESSOR CONTENTS 1 GENERAL CHARACTERISTICS Page 2 1.1 General description Page 2 2 EMIPRO USER INTERFACE Page

More information

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL USER MANUAL Read carefully before use GENERAL INFORMATION This device is a gas control unit with RS485 serial communication, based

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information

REPEATER FS5200R INSTRUCTION MANUAL

REPEATER FS5200R INSTRUCTION MANUAL REPEATER FS5200R INSTRUCTION MANUAL Instruction Manual Page1 CONTENTS 1. Introduction... 3 2. Function... 3 3. Technical data... 3 4. Contents of delivery... 4 5. General information... 5 6. Duty Mode...

More information

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL Microener- Copyright 2010 FW 2.1 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL Advanced Gen-set Controller OPERATOR S MANUAL Display readings Push-button functions Alarm handling Log list Document no.: 4189340607A SW version 3.5X.X or later Table of contents 1. ABOUT THIS DOCUMENT...3

More information

RCS Residential Control Systems Inc.

RCS Residential Control Systems Inc. RCS Residential Control Systems Inc. Model TZ16 Z-Wave Communicating Thermostat with Rev P HVAC Control Unit INSTALLATION AND OPERATION MANUAL DCN: 141-00882 Rev 02 5/18/06 This manual applies to the following

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

FLOW CONTROLLER TYPE S/601

FLOW CONTROLLER TYPE S/601 Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This

More information

ALARM SYSTEM USER S MANUAL Rev

ALARM SYSTEM USER S MANUAL Rev ALARM SYSTEM USER S MANUAL Rev.06 890-00011 Manufacturer: Viatron Electronics 3514 1st Street, St-Hubert (Quebec) Canada J3Y 8Y5 WARNINGS the warranty can be void if the Agri-Alert 2400 is used in a manner

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

TE809-Ats Instructions Manual

TE809-Ats Instructions Manual TE809-Ats Instructions Manual Project: v2.0 PREFACE Thanking you for preference, TECNOELETTRA SRL hopes that the use of this equipment could be a reason of satisfaction. This manual is designed to put

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL. Page 1 / 15 Installation and user manual Page 2 / 15 Sira s.r.l. reserves the right to make modifications to this manual and the product described herein without prior notice. Sira s.r.l. shall not be

More information

User Manual Ichill 200 L/D (Firmware version 1.7)

User Manual Ichill 200 L/D (Firmware version 1.7) User Manual Ichill 2 L/D (Firmware version 1.7) Pag. 1 of 142 INDEX 1. GENERAL FEATURES...8 1.1 Main Function... 8 2. ICHILL 2L/D TABLE OF THE FEATURES...1 3. USER INTERFACE...11 4. REMOTE KEYBOARD...15

More information

Index. 1. General description of the application Types of units controlled Types of regulation Condensation...

Index. 1. General description of the application Types of units controlled Types of regulation Condensation... LCS pco ADVANCED MICROPROCESSOR USER MANUAL GB Index 1. General description of the application... 4 1.1. Types of units controlled...4 1.2. Types of regulation...4 1.3. Condensation...4 1.4. Safety devices

More information

OPERATING MANUAL Enertronic Control System 2

OPERATING MANUAL Enertronic Control System 2 OPERATING MANUAL Enertronic Control System 2 The integrated control system for Lennox chillers in the Ecologic range Manufacturer: Lennox Benelux B.V. Postbus 1028, 3860 BA NIJKERK Watergoorweg 87, 3861

More information

ENERGY 200 Electronic Control for mono & bi- Compressor CHILLERS. User Manual

ENERGY 200 Electronic Control for mono & bi- Compressor CHILLERS. User Manual Electronic Control for mono & bi- Compressor CHILLERS User Manual 2/55 1 CONTENTS 1 Contents...3 2 How to use this manual...5 3 Introduction...6 3.1 Components...6 3.1.1 Basic module...6 3.1.2 Keyboards...6

More information

ELECTRONIC AIR CONDITIONING CONTROL

ELECTRONIC AIR CONDITIONING CONTROL 1 ELECTRONIC AIR CONDITIONING CONTROL TH-T500 Simplified Driver s panel TH-T505 Complete Driver s panel TH-T510 Control box THERMOBUS INSTRUCTION MANUAL FOR OPERATOR PHONE: +39 035 4997266 FAX: +39 035

More information

Small in size, with grand features USER GUIDE Elle-même petite, mais avec caractéristique grand

Small in size, with grand features USER GUIDE Elle-même petite, mais avec caractéristique grand 1 Small in size, with grand features USER GUIDE Elle-même petite, mais avec caractéristique grand 2 PARAMETER LIST 00 Elevator Type 01 Command Type 02 Door Type 03 Automatic Door at Floor 04 Automatic

More information

SCIENTIFIC WARMING CABINET Installation, Operation and Maintenance Instructions

SCIENTIFIC WARMING CABINET Installation, Operation and Maintenance Instructions SCIENTIFIC WARMING CABINET Installation, Operation and Maintenance Instructions GENERAL 2 Inspection 2 Location 2 INSTALLATION 2 Door Alignment 2 Shelf Installation 2 Remote Contacts 3 2-10 Volt DC Output

More information

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION PRODUCT BULLETIN ISSUE/DATE: March 28, 2008 rev A BULLETIN NUMBER: AQ032808 SUBJECT: Monitoring Station PRODUCT LINE: Aquafine UV Equipment TOPIC: REVISION TO THE 41114-1 MONITORING STATION OVERVIEW /

More information

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller 339,95 195,85 0 2 89,35 14,15-1 Four Steps Chiller Heat Pump Controller 1 CONTENTS 1 Contents...2 2 How to use this manual...4 3 Introduction...5 3.1 Components...5 3.1.1 Basic Module...5 3.1.2

More information

Electro-Sentry. Users Manual

Electro-Sentry. Users Manual Electro-Sentry Users Manual 2. To view an individual point, e.g. Speed just touch that point and it will display a graph showing the 45 min. of activity. Viewing a Leg: 1. Touch the desired leg, e.g. East

More information

Refrigerated air dryers

Refrigerated air dryers Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...

More information

Entero Voice Alarm system.

Entero Voice Alarm system. Entero Voice Alarm system. Entero ESC installation menu guide Rev. 1.0 The manufacturer reserves specification privileges. Information in this manual is subject to change without prior notice or obligation.

More information

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System Quick-Start Installation Guide Document Number 44I00-1 Rev. 2.12 February, 2006 For complete operation and programming instructions,

More information

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL M 890-00279 rev. 14 K 895-00004 rev. 00 Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS The warranty can be void

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

DIGITAL TEMPERATURE RELAY TR-100

DIGITAL TEMPERATURE RELAY TR-100 LTD Research-and-Manufacture Company DIGITAL TEMPERATURE RELAY USER S MANUAL www.novatek-electro.com - 2 - Service manual is intended for getting acquaints with hardware, operation principals, modes of

More information

EasyTech.One Temperature Controller for Pellet Burner

EasyTech.One Temperature Controller for Pellet Burner EasyTech.One Temperature Controller for Pellet Burner Burner 1 INTRODUCTION... 3 2 ELECTRICAL CONNECTIONS... 3 3 CONTROL PANEL: USE AND FUNCTIONS... 5 3.1 LED... 5 3.2 BUTTONS... 5 3.3 ALARMS... 5 3.1

More information

Installation and User Instructions

Installation and User Instructions Installation and User Instructions The Informant is a self-contained alarm and logging device that uses the cellular phone network. Text message alarms are sent up to five cell phones. Events are logged

More information

Application Manual Loop Water Controller

Application Manual Loop Water Controller Application Manual Loop Water Controller AM - LWC TABLE OF CONTENTS LIST OF FIGURES ii iii 1.0 SAFETY CONSIDERATION 1 1.1 Installation Recommendations 1 2.0 GENERAL DESCRIPTION 2 2.1 General Introduction

More information

PROGRAMMABLE 7-DAY RF THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control

More information

Gas Detection System TOX ALARM DG2000-Garage

Gas Detection System TOX ALARM DG2000-Garage Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE

More information

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL WATER HEATER ELECTRONIC CONTROLLER USER MANUAL UPPER LED READOUT LED ICONS LOWER LED READOUT PVI INDUSTRIES, LLC - Fort Worth, Texas 76111 - Web www.pvi.com - Phone 1-800-433-5654 Page 1 / 7 PV500-40 03/17

More information

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position,

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

ST Wiring diagram. Product description. Four-stage controller. Order number

ST Wiring diagram. Product description. Four-stage controller. Order number ST96-35.16 Four-stage controller Order number 99.2 Wiring diagram Product description The four-stage controller with 4-digit setpoint and actual value display, 3 keys and 4 relays was developed for the

More information

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING Tempered Water Logic Control OPERATION l TROUBLE SHOOTING English For MPE Multiple Chiller Units Control Panel TEMPERED WATER SYSTEMS L-2199 Rev. 20080223 Revision: L-2199 20101104 *** IMPORTANT NOTICE

More information

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual DNC-PS700-A10 Differential Pressure Control Meter Operation and Installation Manual NationalControlsCorp. Phone 800-323-2593 Fax 630-231-1377 www.nationalcontrols.com MII-PS700-011 N ationalc o ntro ls

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

Farm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1.

Farm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1. Manual for use and maintenance Farm Hand CCU 111 / CCU 10R Farm Hand Climate Controller HC/MMA/UmGB-2043-01/13 rev 1.8 P/N: 110131 Farm Hand CCU 111, Farm Hand CCU 10R Manual for use and maintenance Revision:

More information

EasyTech.Full Temperature Controller for Pellet Stove. Idro

EasyTech.Full Temperature Controller for Pellet Stove. Idro EasyTech.Full Temperature Controller for Pellet Stove EasyTech.One is a Pellet stoves control system available in Air and Hydro version. Is characterised by: Installing and use simplicity Simple and direct

More information

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL RX808-LCD 80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY 14.12-M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL WARNINGS Installation: This device must be installed only by qualified

More information

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420

More information

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1

More information

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS) 1 INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS) SECTION TITLE PAGES 1 Introduction and Basic Operation 2-3 2 Cleaning & Storing 4 3 Basic

More information

ZSC100 Gas Detection and Alarm System Controller

ZSC100 Gas Detection and Alarm System Controller ZSC100 Gas Detection and Alarm System Controller User Guide 1- Introduction... 3 1.1- General description... 3 1.2- Cautions and warnings... 3 2- Control panel... 4 2.1 Control panel overview... 4 2.2

More information

Installer Manual KNX Touchscreen Thermostat

Installer Manual KNX Touchscreen Thermostat Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY

More information

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort USER MANUAL S203 Controller for three circuits - control for 2 heating circuits - 1 domestic hot water control Saving energy, creating comfort This user manual consists of two parts. Issues that are intended

More information

XLH210: controller for gas leak detectors

XLH210: controller for gas leak detectors pag. 1 / 7 XLH210: controller for gas leak detectors Dixell introduces the new digital controllers designed to be combined with 4 20mA gas leak detectors. XLH210 is a microprocessor based controller, designed

More information

Product Manual SZ1145

Product Manual SZ1145 Product Manual SZ114 General Purpose Monitor Communicating Controls Description The SZ114 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum temperature

More information

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440) Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

SERVICE MANUAL REFRIGERATED AIR DRYER DIGI-PRO CONTROLLER WARRANTY NOTICE

SERVICE MANUAL REFRIGERATED AIR DRYER DIGI-PRO CONTROLLER WARRANTY NOTICE REFRIGERATED AIR DRYER SERVICE MANUAL DIGI-PRO CONTROLLER WARRANTY NOTICE Failure to follow the instructions and procedures in this manual or misuse of this equipment will VOID any warranty. 1. USER INTERFACE

More information

user manual Document No , Revision 03 November 2015

user manual Document No , Revision 03 November 2015 user manual Document No. 996-202-600-3, Revision 03 November 2015 Contents 1 Introduction...1 1.1 Notice...1 1.2 Models...1 2 User Control Levels...2 2.1 Level Definition...2 2.2 User Passwords...2 3 Controls

More information

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

Service control manual Smart HP. Application FLBB0mHPGU

Service control manual Smart HP. Application FLBB0mHPGU Service control manual Smart HP Application FLBB0mHPGU 1 Summary 1. INTRODUCTION...3 1.1 Purpose of the manual...3 2. SYSTEM ARCHITECTURE...4 2.1 Main control components...4 3. USER INTERFACE...5 3.1 Terminal...5

More information

REMOTE CONTROL FOR CHILLER MYCHILLER

REMOTE CONTROL FOR CHILLER MYCHILLER REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN

More information

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE SERIES 101T MOISTURE ANALYZER QUICK START GUIDE INSTALLATION The moisture probe may be installed directly into the sample stream through a ½ inch NPT adapter (See Fig. 1). The penetration into the sample

More information

Model TZ43. ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: /22/08 *** IMPORTANT NOTICE ***

Model TZ43. ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: /22/08 *** IMPORTANT NOTICE *** RCS Model TZ43 ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: 141-01652-03 9/22/08 *** IMPORTANT NOTICE *** DO NOT USE THIS PRODUCT FOR BUILDING FREEZE PROTECTION! YOU ARE ADVISED TO INSTALL A

More information

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT PAC-2000 REV D ELECTRIC COOLING FAN CONTOLLER PAC-2000 REV D FAN CONTROLLER SW1 FAN HIGH FAN LOW GND +12v SENDER A/C IGNITION SW2 CUSTOM ADJUSTMENT Choose option below GAUGE +12 V with key ON A/C clutch

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS G LMS 188 4P BMS August, 2018 LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS! WARNING: This product can expose you to chemicals including lead, which is known

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

OPERATING MANUAL Enertronic Control System 2

OPERATING MANUAL Enertronic Control System 2 OPERATING MANUAL Enertronic Control System 2 The integrated control system for Lennox chillers in the Ecologic and Seconscrew ranges Manufacturer Lennox Benelux B.V. Postbus 1028, 3860 BA NIJKERK Watergoorweg

More information

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF: EC 6-295P220S001 smart guide ON-OFF digital controller for ventilated refrigerating units Version 1.01 of 15 th March 2005 File ec6295p220s001_eng_v1.01.pdf PT EVCO S.r.l. Via Mezzaterra 6, 32036 Sedico

More information

CSP-204 CSP-208 CSP-104 CSP-108

CSP-204 CSP-208 CSP-104 CSP-108 Fire Alarm Control Panel CSP-204 CSP-208 CSP-104 CSP-108 Operation manual Firmware version 1.1 csp-x_o_en 06/15 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. 58 320 94 00 www.satel.eu CONTENTS

More information

ST Wiring diagram. Product description. Standard temperature controller. Order number

ST Wiring diagram. Product description. Standard temperature controller. Order number ST64-31.10 Standard temperature controller Order number 900197.007 Old Id.Nr.: 386169 Wiring diagram Product description The controller ST64-31.10 was developed for simple thermostatic controls. The round

More information

Entero Voice Alarm system. User guide

Entero Voice Alarm system. User guide Entero Voice Alarm system. User guide The manufacturer reserves specification privileges. Information in this manual is subject to change without prior notice or obligation. 2 Table of Contents Introduction...

More information

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1 RF SCOUT PLUS INSTRUCTION MANUAL Dielectric, LLC 22 Tower Rd. Raymond, ME 04071 Phone: 800.341.9678 www.dielectric.com 21 January 2015, Rev B 1 WARNING Powering RF sensors above +30dBm (1W) will cause

More information

eed quality electronic design USER s MANUAL

eed quality electronic design USER s MANUAL eed quality electronic design www.dem-it.com eed www.qeed.it info@qeed.it ANALOG SIGNAL DISPLAY Q-DISP-T USER s MANUAL The displays Q-DISP-T, prepared for mounting on the back panel, 96x48mm, will allow

More information

RCS Residential Control Systems Inc.

RCS Residential Control Systems Inc. RCS Residential Control Systems Inc. Model TR16 Communicating Thermostat With RS485 Communications INSTALLATION AND OPERATION MANUAL Rev P HVAC Control Unit DCN: 141-00930-09 Rev 09 7/13/06 This revision

More information

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits CommStat 4 PRODUCT DATA SHEET Controller for Redundant Telecom HVAC Systems General Description The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners,

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

Product Manual SZ1144

Product Manual SZ1144 Product Manual SZ1144 Refrigeration Temperature Monitor Communicating Controls Description The SZ1144 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum

More information

Lift Station Level Controller

Lift Station Level Controller Lift Station Level Controller Installation and Operation Manual 1 California Motor Controls, Inc. Benicia, CA Table of Contents 1. Features Product Overview... 4-6 Access Security... 7 Optional Features...

More information

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic, No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic, mechanical, by photocopying, recording or in any other manner

More information

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

CEM-24 Series. Owner's Manual - Installation and Operating Instructions CEM-24 Series Owner's Manual - Installation and Operating Instructions Rev. 6.4 01.10 Pipersville, PA 18947 USA Phone: (215) 766-1487 - Fax: (215) 766-1493 Email: support@scillc.com - www.scillc.com Please

More information

XC1008D -XC1011D- XC1015D and VGC810

XC1008D -XC1011D- XC1015D and VGC810 Electronic Controller for Compressor Racks XC1008D -XC1011D- XC1015D and VGC810 Instructions Manual INDEX 1. GENERAL WARNING 4 1.1 PLEASE READ BEFORE USING THIS MANUAL 4 1.2 SAFETY PRECAUTIONS 4 2. WIRING

More information

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2 TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2 1. Product Overview 1.1 Display Large LCD display for measured values and status Time Alarm (will stay lit until Upper / Lower limit value (except for TN2) the

More information

RC-2000 Thermostat Installation Instructions

RC-2000 Thermostat Installation Instructions RC-2000 Thermostat Installation Instructions DESCRIPTION The RC-2000 is a precision digital thermostat designed for 24 VAC heating and cooling systems. The RC-2000 will support the following systems: Single

More information

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1) SY325 Janfire Pellet Burner Boiler for single / double burner management (Version 1.1) TECHNICAL DATA SHEET V1.1 rev.12/2007 Contents INTRODUCTION...3 1 THE CONTROL PANEL...4 2 THE KEYS...4 3 THE LEDS...4

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS

More information