Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options
|
|
- Doreen Osborne
- 5 years ago
- Views:
Transcription
1 Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position, or jumper removed closed = On ON LINE position (default jumper) User Prompt Prompts the user to rotate to On Line position, Just before retransfer. Manual or automatic start (one button) is allowed all the way to load being On-line Not installed open = jumper removed Prompts the user to install jumper just before retransfer Installed without interlock option closed = default jumper Open = Jumper removed Closed = default jumper Manual or automatic start (one button) is allowed all the way to load being On-line Prompts the user to install jumper just before retransfer Prompts the user to verify the switch is in online position before a retransfer is allowed Multiple Battery Cabinets Dual-Lite TRN 36 Operation
2 NUMBER OF BATTERY CABINETS MIN MAX 1 6 6HWWKHQXPEHURIEDWWHU\FDELQHWVE\FKDQJLQJWKHQXPEHULQWKHKLJKOLJKWHGER[3UHVVLQJ 6(/(&7ZLOOVDYHWKLVLQIRUPDWLRQDQGUHWXUQ2SHUDWRUWRWKH6\VWHP6HWWLQJV6FUHHQ 7RVKXWGRZQWKH836QDYLJDWHWRWKH0$,10(18DQGVHOHFW67$ '2:17KLV DFWLRQZLOOGLVSOD\WKH67$ '2:1VFUHHQ)URPWKHUHKLJKOLJKW86(56+87'2:1 DQGSUHVV6(/(&77KHIROORZLQJILJXUHZLOODSSHDU USER SHUTDOWN INVERTER OFF CRITICAL LOAD SHUTDOWN EXIT 7KH2SHUDWRUFDQLQYRNHWZRW\SHVRIVKXWGRZQVIURPWKLVLQWHUIDFHVFUHHQ :KHQ2SHUDWRUVHOHFWV75$16)(5/2$',19(57(52))WKH0$18$/75$16)(5 5(75$16)(5VFUHHQLVGLVSOD\HG7KLVDOORZVWKH2SHUDWRUWRWUDQVIHUWKHFULWLFDOORDGLQDQGRXW RIWKHVWDWLFVZLWFKE\SDVV7KLVVFUHHQFDQEHDFFHVVHGRQO\ZKHQWKHURWDU\VZLWFKLVLQ1RUPDO SRVLWLRQ7KHVFUHHQLVDFFHVVHGIURPWKH0$,10(18
3 MANUAL TRANSFER / RETRANSFER BYPASS OK INVERTER OK INT. BYP. SWITCH NORMAL EXT. MAINT. SWITCH ON-LINE INVERTER LAG 1 DEGREE OK TRANSFER TO BYPASS EXIT MANUAL TRANSFER / RETRANSFER BYPASS NOT OK INVERTER OK INTERNAL BYPASS SWITCH NORMAL EXT. MAINT. SWITCH ON-LINE INVERTER IN SYNC TRANSFER NOT ALLOWED OK EXIT 7KHPHVVDJH5HWUDQVIHUWR836RU7UDQVIHUWR%\SDVVZLOODSSHDUGHSHQGLQJRQVWDWXVRIWKHFULWL FDOORDG7KHRSHUDWRUKDVWZRFKRLFHV(LWKHUWRDFFHSW2.RU(;,7,IDWUDQVIHURUUHWUDQVIHULV QRWDOORZHGWKH)/$6+,1*PHVVDJH7UDQVIHU1RW$OORZHGLVGLVSOD\HG3UHVV(;,7WRUHWXUQWR WKH0$,10(18 )RUPRUHLQIRUPDWLRQVHH6HFWLRQ 0DQXDO7UDQVIHU 6WDWXV5HSRUWVFRQWDLQVHTXHQWLDOLQIRUPDWLRQDERXWIDXOWDQGDODUPVLJQDOV7RDFFHVVWKH6WDWXV 5HSRUWVFUHHQVQDYLJDWHWRWKH0$,10(18DQGKLJKOLJKW67$7865(325763UHVVWKH6HOHFW EXWWRQDQGWKHIROORZLQJ67$7865(32576VFUHHQLVGLVSOD\HG
4 STATUS REPORTS HISTORY LOG 1 HISTORY LOG 2 SYSTEM STATUS CLEAR HISTORY LOGS CLEAR EVENT LOG EXIT 7KH6WDWXV5HSRUWVFUHHQLVGLYLGHGLQWRVL[VXEPHQXV(9(17/2*+,6725</2*+,6725< /2*6<67(067$786&/($5+,6725</2*6DQG&/($5(9(17/2*6 7RORRNDWDQ\RIWKHUHSRUWVGRWKHIROORZLQJ 7RUHWXUQWRWKH0DLQ0HQXKLJKOLJKW(;,7DQGSUHVV6HOHFW Communication Interfaces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
5 EVENT LOG MESSAGE: SYS TIME SET BY OP TYPE: ALARM INITIATED BY: MICRO MONITOR TOTAL PREV NEXT EXIT 02 : 24 : 21 6 / 10 / 00 EVENT LOG MESSAGE: UPSC - MM COMMUNICATION FAIL TYPE: ALARM INITIATED BY: MICRO MONITOR TOTAL PREV NEXT EXIT 02 : 23 : 21 6 / 10 / 00 EVENT LOG MESSAGE: SYS TIME SET BY OP TYPE: ALARM INITIATED BY: MICRO MONITOR TOTAL PREV NEXT EXIT 02 : 20 : 21 6 / 10 / 00
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
7 7KHVHFRQGSDJHLVWKH67$786ZKLFKLQFOXGHV HISTORY LOG 1 P2 - STATUS 14 : 19: / 10 / 00 SBS LINE SBS LOAD INP DELTA OUTPUT TRAP INT. MBP SERVICE EXT. MBP OPEN BATT CB OPEN SBS OFF RECT. OFF INV. OFF PREV NEXT ALARMS METER EXIT FRAME 0 7KHODVWSDJHLQFOXGHVIDXOWV7KHDODUPFRQGLWLRQVWKDWFDXVHWKH+LVWRU\6WDWXVEXIIHUWRVWRUH DQGIUHH]HGDWDDUH
8 Figure 39 History Log Faults/Alarms Report Screen HISTORY LOG 1 P3 - FAULTS / ALARMS 14 : 22: / 10 / 00 DC OV TRANSIENT INPUT OF / UF RECTIFIER FUSE FAIL INPUT OF / UF NEXT PREV METER STATUS EXIT FRAME 40 NOTE The Emergency Off and Hardware Shutdown alarms will also freeze the History Status buffer with the Auto Transfer to Bypass alarm (if the load is on the UPS system when the alarm condition occurs) Configuration Screens Dual-Lite System Services (DSS). Figure 40 Configuration Screen CONFIGURATION SYSTEM SETTINGS USER SETTINGS FACTORY SETTINGS ALARM MASK CUSTOMER ALARM INTERFACE EXIT DSS Operation 43
9 7KH6\VWHP&RQILJXUDWLRQVFUHHQLVFDWHJRUL]HGDVD6HFXULW\$FFHVVVFUHHQ7KLVPHDQVWKDWDQ\ RQHPD\UHYLHZWKHSUHVHQWSDUDPHWHUVEXWRQO\DXWKRUL]HG2SHUDWRUVPD\PDNHFKDQJHV6HH 6HFWLRQ IRUPRUHLQIRUPDWLRQRQ6HFXULW\$FFHVVDQG3DVVZRUGV 7KHILUVWWLPHWKH836LVSRZHUHGXSE\/*6LWDOORZVWKH2SHUDWRUWRQDYLJDWHWKURXJKDOORIWKH PHQXRSWLRQVLQRUGHUWRSURJUDPWKH1RQ9RODWLOH5$07KLVLVUHIHUUHGWRDVWKH&2/'67$57 7KHUHDIWHURQO\WKH6<67(05$7,1*6DQG2SHUDWRU6(77,1*6FDQEHFKDQJHGZLWKRXW6HFX ULW\$FFHVV
10 System Ratings DSS Figure 41 System Ratings, page 1 SYSTEM RATINGS KVA 40 SYSTEM POWER FACTOR 0.8 INPUT VOLTS 480 OUTPUT VOLTS 208 BYPASS VOLTS 480 NEXT EXIT NOTE The only time the System Ratings can be changed is when the UPS is first powered up. After that, they remain locked. Figure 42 System Ratings, page 2 SYSTEM RATINGS DC BUS VOLTS 540 INPUT FREQUENCY 60.0 OUTPUT FREQUENCY 60.0 PREV EXIT System Settings Operation 45
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
12 3.5 - Communication Interfaces CURRENT TIME SYSTEM SETTINGS ORDER NUMBER SYSTEM CONFIG SMS SYSTEM / MODULE 1 NUMBER OF MODULES IN SYSTEM 1 NUMBER OF BATTTERY CABINETS 1 NEXT PREV. CANCEL SAVE & EXIT 7RFRQWLQXHFRQILJXULQJWKHV\VWHP+LJKOLJKW1(;7DQGSUHVV6(/(&7
13 SYSTEM SETTINGS SINGLE / DUAL INPUT DUAL OUTPUT TRANSFORMER BYPASS WIND. NO BYPASS AUTO TRANSFORMER T3 NO OPTIONS... COMM. OPTIONS... PREV. CANCEL SAVE & EXIT 7KH6LQJOH'XDO,QSXW6FUHHQLVSDVVZRUGSURWHFWHG6HH6HFWLRQ IRUPRUHLQIRUPDWLRQRQ 6HFXULW\$FFHVVDQG3DVVZRUGV$IWHUKLJKOLJKWLQJ6LQJOH'XDO,QSXWIURPWKH6\VWHP6HWWLQJV 6FUHHQDQGSUHVVLQJ6(/(&7WKHIROORZLQJVFUHHQZLOODSSHDU ENTER PASSWORD <RXPXVWHQWHU\RXUVHFXUHSDVVZRUGWRDFFHVVWKHQH[WVFUHHQ7KHSRVLWLRQRIHDFKRIWKHIRXUGLJ LWVRIWKHSDVVZRUGLVLQGLFDWHGE\WKHPDUNEHORZWKH]HUR7KHV\VWHPZLOOUHPDLQSDVVZRUGIUHH IRUILYHPLQXWHVDOORZLQJFKDQJHVWREHPDGH +LJKOLJKWLQJHLWKHU6LQJOHRU'XDODQGSUHVVLQJ6(/(&7VDYHVFKDQJHVDQGUHWXUQVWKH2SHUDWRU WRWKH6\VWHP6HWWLQJVVFUHHQ SINGLE / DUAL INPUT
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µRQSDJH RIWKH2SWLRQV0DQXDO 10% PASSIVE FILTER SETTINGS FILTER DISCONNECT LEVEL 0 FILTER PREFERRED STATE CLOSED 10% PASSIVE FILTER CONTACTOR DISABLE EXIT
15 OPTIONS 12 PULSE RECTIFIER 6 PULSE BATTERY GND FAULT NO GREEN MACHINE NO FREQUENCY CONVERTER NO LINE DROP COMPENSATION NO NEXT PREV. EXIT OPTIONS ALTERNATE POWER POLE FAN AUX. TEMP. SFA MOTORIZED BATT. BREAKER BATT. CELL MONITOR NO NO NO MANUAL NO NEXT PREV. EXIT OPTIONS EXTERNAL MAINT. BYPASS NO PREV EXIT &20081,&$7,21237,216 &RPPXQLFDWLRQRSWLRQVDUHWKHYDULRXVRSWLRQVWKDWHQDEOHWKHRSHUDWRUWRYLHZGDWDIURPUHPRWH ORFDWLRQVDQGWRSURJUDPWKHW\SHRIGDWDWREHYLHZHG)RUGHWDLOHGLQIRUPDWLRQVHH6HFWLRQ &RPPXQLFDWLRQ,QWHUIDFHV
16 7KHFRPPXQLFDWLRQRSWLRQVVFUHHQVFDQEHDFFHVVHGIURPWKHWKLUGSDJHRIWKH6\VWHP6HWWLQJV VFUHHQ6HH)LJXUH COMMUNICATION OPTIONS MODEM DISABLED PROGRAMMABLE RELAY #1 YES PROGRAMMABLE RELAY #2 YES INPUT CONTACT ISOLATOR YES REMOTE ALARM #1 YES NEXT EXIT 7KH,QWHUQDO0RGHP2SWLRQDOORZVWKHV\VWHPWRGLDORXWRUUHFHLYHLQFRPLQJFDOOV7RVHWGLDOLQJ IHDWXUHVDQGWRHQDEOHLQWHUQDORUH[WHUQDOPRGHPSUHVV02'(0RQWKHILUVWSDJHRIWKH&RPPX QLFDWLRQV2SWLRQVVFUHHQ7KH$XWR'LDOVFUHHQZLOOEHGLVSOD\HG AUTO DIAL MODEM PRIMARY LINE SECONDARY LINE INIT. STRING ATSO = 1 MAX. BAUD RATE 2400 INTERNAL NEXT EXIT 7RJHWWRWKH0RGHP6HOHFWLRQVFUHHQKLJKOLJKW02'(0DQGSUHVV6(/(&77KHIROORZLQJVFUHHQ ZLOOFRPHXSVKRZLQJWKDWWKHPRGHPLVGLVDEOHG ',6$%/(' EXTERNAL INTERNAL DISABLED
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
18 $SDVVZRUGLVUHTXLUHGWRHQWHUDSDJHUQXPEHUDQGFKDQJHWKHSDJHUSLQQXPEHU6HH)LJXUH DQG6HFWLRQ 6HFXULW\$FFHVVDQG3DVVZRUGV3UHVV6(/(&7ZLOOUHWXUQWKH2SHUDWRUWR WKH&RPPXQLFDWLRQV2SWLRQV6FUHHQ6HH)LJXUH 7RJRWRWKHVHFRQGSDJHRIWKH&RPPXQLFD WLRQV2SWLRQV6FUHHQEUDFNHW1(;7DQGSUHVV6(/(&77KHIROORZLQJVFUHHQZLOOFRPHXS COMMUNICATION OPTIONS REMOTE ALARM #2 NO REMOTE ALARM # 3 SITESCAN NO NO NIC AS 400 NO NO NEXT PREV. EXIT 6HOHFW1(;7WRJRWRWKH&RPPXQLFDWLRQ2SWLRQVVFUHHQWKLUGSDJH 7KH8VHU6HWWLQJVDUHDFFHVVHGIURPWKH&RQILJXUDWLRQ6FUHHQ)LJXUH USER SETTINGS OUTPUT PLL PHASE ADJUST 0.0 OUTPUT PLL SLEW RATE 0.5 OUTPUT PLL SYNC RANGE 1.0 DC BUS FLOAT VOLT 540 BATT. CHARGE I LIMIT 1.6 NEXT CANCEL SAVE & EXIT
19 USER SETTINGS BATT. TIME LOW WARNING 5 BATT. TIME (T 1) AT 100% 15 BATT. TIME (T 2) AT 50% 45 BATT. EOD LOWER SET POINT 384 BATT. EOD UPPER SET POINT 427 NEXT PREV. CANCEL SAVE & EXIT USER SETTINGS BATT. EOD RAMP START 15 BATT. EOD RAMP END 60 BATT. TEMP. ALARM LIMIT 40 BATT. COMPARTMENT TEMP. LIMIT 50 INPUT PLL PHASE ADJUST 0.0 NEXT PREV. CANCEL SAVE & EXIT USER SETTINGS INPUT PLL SLEW RATE 0.5 INPUT PLL SYNC RATE 1.0 INPUT I LIMIT WALK-IN 10 LCD CONTRAST LED BRIGHTNESS NEXT PREV. CANCEL SAVE & EXIT
20 USER SETTINGS ALARM AUDIO LEVEL AUX. TEMPERATURE LIMIT 40 AUTO REXFER COUNTER / HR. 5 BATT. GND FAULT BREAKER TRIP YES 10 % PASSIVE FILTER SETTINGS NEXT PREV CANCEL SAVE & EXIT +LJKOLJKWLQJ3$66,9(),/7(56(77,1*6ZLOOEULQJXSWKHIROORZLQJ2SHUDWRULQWHUDFWLYH VFUHHQ 10 % PASSIVE FILTER SETTINGS FILTER PREFERRED STATE OPEN 10 % PASSIVE FILTER ENABLED EXIT USER SETTINGS AUTO RESTART SETTING SYSTEM ACTIVE FILTER ENABLE ENABLED TEMPERATURE BATT. CB TRIP NO CHANGE PASSWORD INTERRUPTED TRANSFER ENABLE DISABLE PREV. CANCEL SAVE & EXIT
21 FACTORY SETTINGS OUTPUT AC VOLTS AN 120 OUTPUT AC VOLTS BN 120 OUTPUT AC VOLTS CN 120 OUTPUT OF / UF 0.5 INVERTER DC OFFSET PHASE A NEXT CANCEL SAVE & EXIT FACTORY SETTINGS INVERTER DC OFFSET PHASE B INVERTER DC OFFSET PHASE C INPUT I LIMIT WITH TRAP INPUT I LIMIT WITHOUT TRAP INPUT I LIMIT ON GENERATOR 100 NEXT PREV. CANCEL SAVE & EXIT FACTORY SETTINGS INPUT PID LOOP ON GENERATOR DELAYED RESTART 10 BYPASS / OUTPUT PHASING 30 PREV. CANCEL SAVE & EXIT
22 Alarm Dual-Lite Systems Services Operation 57
23 (9(17/2**,1* 7KHOLVWRIDODUPVWKDWFDQEHPDVNHGDUHVKRZQLQ7DEOH 6HFWLRQ 0RVW(YHQWVDUHDXWR PDWLFDOO\ORJJHGLQWRWKH(YHQW+LVWRU\%XIIHU7KRVHZKLFKFDQEHVHOHFWHGRUGHVHOHFWHGE\WKH XVHUDUH '(/$< 7KLVUHIHUVWRWKHWLPHLQVHFRQGVWKDWPXVWRFFXUEHIRUHWKH836UHFRJQL]HVDQDODUPIXQFWLRQ 7KHGHOD\FDQEHDQ\ZKHUHIURPWRVHFRQGVLQVHFRQGLQWHUYDOV,IDQDODUPLVVHWWR /DWFKLWZLOORQO\UHFRJQL]HWKHDODUPDQGODWFKDIWHUWKHGHOD\SHULRG ALARM / FAULT NAME ALARM / FAULT NAME L D F E BATT. FUSE FAIL Y Y Y N N Y Y BATT. LOW TRANSFER Y Y Y Y DC OV TRANSIENT Y Y Y Y INPUT PHASE ROT ERROR N N N Y RECTIFIER FUSE FAIL Y Y Y Y RECTIFIER DRIVE 1 FAIL Y Y Y Y UP DOWN SELECT EXIT DESCRIPTION: L - Latching...D - Dial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
24 Figure 72 Alarm Edit Screen ALARM / FAULT NAME LATCHING DIAL FREEZE EVENT LOG BATTERY FUSE FAIL YES YES NO YES SAVE & EXIT CANCEL AUTO DIAL TRN NOTE Some attributes cannot be edited. TRN 1. From the System Configuration screen, press the Up or Down button to move the highlighted cursor to Auto Dial and press SELECT. 2. The Auto Dial screen will appear. Highlight and select the first Auto Dial Number. 3. Press SELECT to move the arrow to the right. 4. To change a digit, press Up to increase the number or press the Down button to decrease it. Press Select to set the value and move to the next digit. 5. After changes have been made, press SELECT again to return to the System Configuration screen. 6. If required, go to the Second Number screen and enter the correct number. 7. If required, go to the Modem Baud Rate screen and choose from the available baud rates. Operation 59
25 Customer Alarm Interface TRN TRN Figure 73 Customer Alarm Interface Screen CUSTOMER ALARM INTERFACE RELAY BOARD # 1 RELAY BOARD # 2 CONTACT BOARD NEXT CANCEL SAVE & EXIT AS400 NOT INSTALLED Figure 74 Customer Alarm Interface Screen, page 2 CUSTOMER ALARM INTERFACE REMOTE LED BOARD # 1... REMOTE LED BOARD # 2... REMOTE LED BOARD # 3 PREV CANCEL SAVE & EXIT 60 Operation
26 7RDFFHVVWKH3URJUDPPDEOH5HOD\%RDUGKLJKOLJKW5(/$<%2$5'IURPWKHILUVWSDJHRI WKH&86720(5$/$50,17(5)$&(VFUHHQDQGSUHVV6(/(&7WREULQJXSWKHIROORZLQJVFUHHQ PROGRAMMABLE OUTPUT RELAY BOARD # 1 RELAY ASSIGNMENTS...AS400 PROGRAMMABLE RELAY # 1 PROGRAMMABLE RELAY # 2 PROGRAMMABLE RELAY # 3 CANCEL BATTERY DISCHARGING LOW BATTERY WARNING LOAD ON UPS / LOAD ON BYPASS SAVE & EXIT 7KH$6SUHDVVLJQHGUHOD\VDUHVKRZQLQWKLVVFUHHQ 7RFKDQJHWKHUHOD\DVVLJQPHQWVHOHFW5(/$<$66,*10(176IURPWKHVFUHHQDQGSUHVV 6(/(&77KHIROORZLQJVFUHHQZLOODSSHDU RELAY ASSIGNMENTS AS400 STD SET USER DEFINED,I\RXVHOHFW67'6(7WKHIROORZLQJVFUHHQZLOOEHGLVSOD\HG PROGRAMMABLE OUTPUT RELAY BOARD # 1 RELAY ASSIGNMENTS...STD SET PROGRAMMABLE RELAY # 1 PROGRAMMABLE RELAY # 2 PROGRAMMABLE RELAY # 3 PROGRAMMABLE RELAY # 4 CANCEL LOAD ON UPS LOAD ON BYPASS BATTERY DISCHARGE LOW BATTERY WARNING SAVE & EXIT
27 PROGRAMMABLE OUTPUT RELAY BOARD # 1 RELAY ASSIGNMENTS...STD SET PROGRAMMABLE RELAY # 5 PROGRAMMABLE RELAY # 6 PROGRAMMABLE RELAY # 7 OVERLOAD AMBIENT OVER TEMP SYS SUMMARY ALARM PREV SAVE & EXIT,IWKH2SHUDWRUVHOHFWV86(5'(),1('IURPWKH5(/$<$66,*10(176VFUHHQWKHIROORZLQJ VFUHHQZLOOFRPHXS PROGRAMMABLE OUTPUT RELAY BOARD # 1 RELAY ASSIGNMENTS...USER DEFINED PROGRAMMABLE RELAY # 1 PROGRAMMABLE RELAY # 2 PROGRAMMABLE RELAY # 3 PROGRAMMABLE RELAY #4 CANCEL PROGRAMMABLE RELAY #5 PROGRAMMABLE RELAY #6 PROGRAMMABLE RELAY #7 PROGRAMMABLE RELAY #8 SAVE & EXIT $OO8VHU'HILQHGUHOD\VDUHSURJUDPPDEOH 7REHJLQSURJUDPPLQJWKH8VHU'HILQHG5HOD\VKLJKOLJKWWKHUHOD\WREHSURJUDPPHGDQGSUHVV WKH6(/(&7EXWWRQ7KLVDFWLRQZLOOEULQJXSWKH/LVWRI$ODUPV)DXOWVVFUHHQ)LJXUH,QL WLDOO\WKHER[EHQHDWKWKHUHOD\ZLOOEHHPSW\ 7RDWWDFKDQDODUPWRHDFKUHOD\IROORZWKHVWHSVEHORZXQGHU1DYLJDWLQJ3URWRFRO
28 Figure 80 List of Alarm Faults Screen ALARM / FAULT NAME BATT. FUSE FAIL BATT. LOW XFER DC OV TRANSIENT INP PHASE ROT ERROR RECT. FUSE FAIL RECT DRIVE 1 FAIL PROG RELAY # 1 BATTERY FUSE FAIL UP DOWN ADD REMOVE CLEAR EXIT NOTE If the TRN has Open Comms-Discrete Inputs (Input Contact Isolators, Section 7 of the Options Manual, these will show up on the alarm list and can be selected to connect to a programmable output relay. TRN Operation 63
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
30 ,QWKHILJXUHDERYHWKHPHVVDJH 75$16)(5127$//2:('µZLOOEHIODVKLQJ 7KH%DWWHU\0DQDJHPHQWVFUHHQVGLVSOD\LQIRUPDWLRQRQEDWWHU\VHOIWHVWVEDWWHU\HTXDOL]DWLRQ EDWWHU\WHPSHUDWXUHDQGEDWWHU\F\FOHPRQLWRULQJ7KLVLQIRUPDWLRQHQDEOHVWKHRSHUDWRUWRLPPH GLDWHO\VHHWKHHIIHFWVRIORDGVKHGGLQJRQWLPHUHPDLQLQJDQGWRDFFXUDWHO\DVVHVVUHPDLQLQJSRZHU UHVRXUFHV7KH%DWWHU\0DQDJHPHQWVFUHHQLVDFFHVVHGIURPWKH0DLQ0HQX BATTERY MANAGEMENT BATTERY TEST BATTERY EQUALIZER BATTERY TEMP COMPENSATION CHARGE BATTERY CYCLE MONITOR BATTERY TIME REMAINING CANCEL SAVE & EXIT 7KH%DWWHU\7HVWVFUHHQDOORZVWKH2SHUDWRUWRVHOHFWEHWZHHQ$XWR7HVWDQG0DQXDO7HVW BATTERY TEST MANUAL TEST LAST BATTERY TEST: BATTERY TEST PASSED EXIT 7KHDXWREDWWHU\VHOIWHVWFDQEHHQDEOHGGLVDEOHGIURPWKH%DWWHU\7HVW6FUHHQ,WLVSHUIRUPHG XQDWWHQGHGE\SURJUDPPLQJ7LPH'DWH7HVW&\FOHDQG7HVW'XUDWLRQLQ%DWWHU\6HOI7HVW6FUHHQ 6HOHFWLQJ0$18$/7(67IURPWKH%DWWHU\7HVWVFUHHQZLOOSHUIRUPDQ2SHUDWRULQLWLDWHGWHVW 7KHIROORZLQJFRQGLWLRQVDQGIHDWXUHVDSSO\WRHLWKHU$XWRRU0DQXDO0RGH,I\RXJRWRWKHEDWWHU\VFUHHQLWZLOOLQGLFDWH %DWWHU\7HVWLQ3URJUHVVµ:KHQWKHWHVWLVFRP SOHWHWKHLQGLFDWLRQ /DVW%DWWHU\7HVWµZLOOHLWKHUVD\ %DWWHU\7HVW3DVVHGµRU %DWWHU\7HVW )DLOHGµ 2QHRIWZRDODUPVDUHORJJHGLQWKHHYHQWORJVFUHHQ %DWWHU\7HVW3DVVHGµRU %DWWHU\7HVW )DLOHGµ,IIDLOHGWKHUHZLOOEHDFFRPSDQ\LQJDODUPPHVVDJHVLQWKHHYHQWORJWRGHVFULEHWKH
31 UHDVRQIRUIDLOXUHLH%DWWHU\5HFKDUJLQJ %DWWHU\7HVW)DLOHGµ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
32 Figure 85 Automatic Test Screen AUTO TEST BATT. TEST TIME 01:02:03 BATT. TEST DATE 07/13/00 CYCLE 2 DURATION 30 EXIT Figure 86 Set Battery Cycle Screen BATTERY CYCLE MIN 2 MAX 9 2 Figure 87 Set Battery Duration Screen BATTERY DURATION MIN 30 MAX 900 SECONDS Battery Equalizer TRN Operation 67
33 BATTERY EQUALIZER CAUTION The manufacturers of the valve-regulated batteries supplied with Dual-Lite s standard battery cabinets recommend that when first installed the batteries be equalize charged. After that initial equalize charge, they recommend no further equalize charging for their batteries. Other manufacturers may have different recommendations for their products. Consult the battery manufacturer s manual for specific information about equalize charging. Figure 88 Battery Equalizer Screen BATTERY EQUALIZER AUTO DISABLE MANUAL EQUALIZE TIME PERIOD 0 EQUALIZE VOLTAGE 540 SAVE EXIT Figure 89 Auto Screen AUTO ENABLED DISABLED 68 Operation
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
35 EQUALIZE VOLTAGE MIN MAX KHHTXDOL]HYROWDJHLVDOVRSURJUDPPDEOH,QWKHH[DPSOHDERYHWKHUDQJHLVWRYROWVZLWK WKHGHIDXOWEHLQJYROWV 7KH%DWWHU\7HPSHUDWXUH&RPSHQVDWLRQ&KDUJHVFUHHQLVDFFHVVHGIURPWKH%DWWHU\0DQDJHPHQW 6FUHHQ)LJXUH 7KH2SHUDWRUFDQHQDEOHRUGLVDEOH%DWWHU\7HPS&RPSHQVDWLRQIXQFWLRQ+H FDQDOVRFKDQJHWKHFRPSHQVDWLRQVHWWLQJE\JRLQJLQWRWKHHGLWVFUHHQ7KHYDOXHVDUHLQPLOOL YROWVGHJUHH& BATTERY TEMP COMPENSATION CHARGE 15 C = TEMPERATURE 20 C C = TEMPERATURE 25 C C = TEMPERATURE 30 C C = TEMPERATURE 35 C 850 NEXT EXIT 7RHQDEOHRUGLVDEOHWKH%DWWHU\7HPSHUDWXUH&KDUJHKLJKOLJKWWKHWRSOLQHLQWKHVFUHHQDERYH DQGSUHVVWKH6(/(&7EXWWRQ7KLVZLOOEULQJXSWKHIROORZLQJVFUHHQ
36 BATTERY TEMP COMPENSATION DISABLE 7RDFFHVVSDJHRIWKH BATTERY TEMP COMPENSATION CHARGE 35 C = TEMPERATURE 40 C C = TEMPERATURE 45 C 750 PREV EXIT 7RHGLWWKH%DWWHU\7HPSHUDWXUH&RPSHQVDWLRQVHOHFWWKHVHFRQGOLQHIURPWKHWRSLQ)LJXUH DQGSUHVVWKH6(/(&7EXWWRQ7KHIROORZLQJVFUHHQZLOOFRPHXS 15 C = TEMPERATURE 20 C MIN 500 MV/ C MAX 1000
37 Battery Cycle Monitor Figure 97 Battery Cycle Monitor Screen BATTERY CYCLE MONITOR BCM DISABLE 0-30 SECONDS DISCHARGE CYCLES SECONDS DISCHARGE CYCLES SECONDS DISCHARGE CYCLES 1 OVER 240 SECONDS DISCHARGE CYCLES 0 NEXT EXIT Dual-Lite Figure 98 Battery Cycle Monitor Screen, page 2 BATTERY CYCLE MONITOR SUMMARY PAGE CLEAR BCM YES / NO CLEAR SUMMARY YES / NO PREV EXIT 72 Operation
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
39 SUMMARY PAGE ACCUMULATED NUMBER OF CYCLES 4 ACCUMULATED BATTERY TIME (SEC) 184 ACCUMULATED BATTERY AMP HOURS 6 ACCUMULATED BATTERY KW HOURS 3 EXIT ',6&+$5*(&<&/('(7(&7,215($50,1*0(7+2' $EDWWHU\GLVFKDUJHF\FOHVWDUWVZLWKWKHUHYHUVDORIEDWWHU\FXUUHQWGLVFKDUJH$0367KHGLV FKDUJHFXUUHQWKDVWREHJUHDWHUWKDQRIEDWWHU\GLVFKDUJHUDWLQJ7KHF\FOHLVWHUPLQDWHGDQG UHDUPHGUHVHWFRQGLWLRQVIRUQH[WF\FOHZKHQEDWWHU\FXUUHQWHQWHUVWKH1RUPDORSHUDWLQJUDQJH RI7KHQRUPDOUDQJHLVGLVSOD\HGDV1250LQWKHEDWWHU\VHFWLRQRIWKHRQHOLQH0LPLF VFUHHQ:KHQEDWWHU\FXUUHQWH[FHHGVLQWKHSRVLWLYHGLUHFWLRQWKHGLVSOD\HGVWDWXVLVFKDQJHG WR&+*FKDUJHDQGZKHQGURSVLQWKHQHJDWLYHGLUHFWLRQE\PRUHWKDQLWLVGLVSOD\HGDV',6 GLVFKDUJH%DWWHU\$036UHVROXWLRQLV :KHQDQ(QGRI'LVFKDUJHFRQGLWLRQRFFXUVIDXOW %$77/2:75$16)(5µWKHF\FOHLVWHUPL QDWHGF\FOHDQGVXPPDU\GDWDVDYHGDQGWKHF\FOHLVUHDUPHG7KHVDPHWKLQJKDSSHQVLQWKH HYHQWRIDORVVRIFRPPXQLFDWLRQVZLWK836&DODUP836&00&200)$,/µ$IWHUDSSUR[L PDWHO\VHFRQGVWKH%&0LVUHDUPHGIRUWKHQH[WF\FOH %&0'$7$'(),1,7, $*( $WWKHVWDUWRIHYHU\GLVFKDUJHF\FOH7LPHDQG'DWHDUHUHFRUGHGDORQJZLWK%DWWHU\&RPSDUWPHQW 7HPSHUDWXUHLQGHJUHHV&:KLOHWKHF\FOHLVLQSURJUHVVWKHIROORZLQJGDWDDUHVWRUHG/RZHVW'& %XV9ROWDJH%DWWHU\.:+RXUVDQG+LJKHVW%DWWHU\'LVFKDUJH$036$WWKHHQGRIWKHF\FOHDOO RIWKHVHSDUDPHWHUVLQFOXGLQJ&\FOH'XUDWLRQLQVHFRQGVDQG6XPPDU\GDWDLQFOXGLQJ$FFXPX ODWHG1XPEHU2I&\FOHV$FFXPXODWHG%DWWHU\$PS+RXUVDQG$FFXPXODWHG%DWWHU\.:KRXUVDUH VWRUHG $WRWDORIF\FOHVDUHVDYHGLQDFLUFXODUEXIIHU %&0$/$50127,),&$7,21 :KHQWKHQXPEHURIF\FOHVH[FHHGVDQDODUPPHVVDJHZLOOEHGLVSOD\HGWRDOHUWWKHXVHUORFDO DQGUHPRWHWKDWWKHHQGRIEXIIHULVQHDU7KHDODUPPHVVDJHGLVGHILQHGDV %$77&<&/( %8))(5)8//µ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
41 7KHIHDWXUHLVSHUPDQHQWO\HQDEOHGDWWKHSUHVHQWWLPHDQGFDQEHLGHQWLILHGE\DQDODUPUHDGLQJ %DWWHU\6XSSOHPHQW$FWLYHµ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µ7KHEDWWHU\W\SHVHWWLQJFDQQRWEHFKDQJHGEDFNWR0DQXDORQFH$XWR 5HVWDUWLVVHWWR<(6+RZHYHULI$XWR5HVWDUW2SWLRQLV'LVDEOHG6HWWR12EDWWHU\W\SHFDQEH LQGHSHQGHQWO\VHWWR0RWRUL]HG7RDFFHVVWKHSURSHUVFUHHQQDYLJDWHWR&RQILJXUDWLRQWKHQ6\V WHP6HWWLQJVWKHQ2SWLRQVWKHQ0RWRUL]HG%DWWHU\%UHDNHUDQGVHOHFW0RWRUL]HG 2QFHLQ$XWR5HVWDUWPRGHDQHZVFUHHQZLOOUHSRUWWKHSURJUHVV6HH)LJXUH
42 AUTO RESTART AUTO RESTART IN PROGRESS QUALIFYING INPUT POWER CANCEL 7KHPHVVDJH$8725(67$57,1352*5(66ZLOOEHGLVSOD\HGGXULQJWKH$XWR5HVWDUW VHTXHQFH7KHWH[WOLQHEHORZWKLVPHVVDJHVLJQLILHVWKHFRQGLWLRQEHLQJFKHFNHGDQGIODVKHVLQ UHYHUVHYLGHRZKLOHWKHPHVVDJHLVGLVSOD\HG 7KH2SHUDWRUFDQFDQFHOWKH$XWR5HVWDUWRSHUDWLRQE\VHOHFWLQJDQGDFNQRZOHGJLQJ&$1&(/ :KHQWKLVLVGRQHDPHVVDJHZLOODSSHDUDVNLQJ &DQFHOLQJZLOODERUW$XWR5HVWDUWRSHUDWLRQ$UH \RXVXUH\RXZDQWWRFDQFHO"7KH2SHUDWRUFDQWKHQVHOHFW<(6RU12µ $WWKHVWDUWRI$XWR5HVWDUWRSHUDWLRQVDQDODUPFRQGLWLRQLVUHFRUGHGWRORJ $XWR5HVWDUW,QLWL DWHGµ,IGXULQJWKHSURFHVV$XWR5HVWDUWLVKDOWHGDVDUHVXOWRIIDLOHGFRQGLWLRQDVXEVHTXHQW DODUPLVUHFRUGHGDV $XWR5HVWDUW)DLOHGµ7KLVZLOOEHDODWFKHGDODUPDQGPXVWEHDFNQRZOHGJHG DQGUHVHWE\WKH2SHUDWRU6HH6HFWLRQ IRUDFRPSOHWHGHVFULSWLRQRIWKHVHDODUPV $Q\WLPHWKH836GHWHFWVDQGUHFRUGVDQ(2'(QGRI'LVFKDUJHFRQGLWLRQRFFXUULQJDWWKHVDPH WLPHWKHLQSXWFRQWDFWRULVRSHQLWUHFRJQL]HVWKDWWKHEDWWHULHVFDQQRORQJHUVXSSRUWWKHORDG 7KLVVFHQDULRVHWVWKH$XWR5HVWDUWIODJLQLWLDWLQJWKH$XWR5HVWDUWVHTXHQFH,QD'XDO,QSXWV\VWHPERWK,QSXWDQG%\SDVVPXVWEHDYDLODEOHWRHQDEOH$XWR5HVWDUW,QDGGLWLRQWRWKHVWDQGDUG836PHWHULQJDQGDODUPLQIRUPDWLRQ1SRZHUPRQLWRUVDQGFDOFXODWHV RWKHUUHOHYDQWGDWD7KLVGDWDFDQEHDFFHVVHGE\VWDUWLQJIURPWKH0DLQ0HQXVHOHFWLQJ6WDWXV 5HSRUWVWKHQ6\VWHP6WDWXV 7KHFRXQWHUVVWDUWIURPWKHWLPH/*6RULQVSHFLDOFDVHVWKHFRQWUDFWRUFRPSOHWHWKHVWDUWXSSURFH GXUHDQGFXVWRPHUDFFHSWVWKHV\VWHP2QFHWKHXQLWLVDFFHSWHG/*6ZLOOJRWRWKH6\VWHP6WDWXV VFUHHQDQGFRPSOHWHWKHVLJQRIISURFHGXUH7KLVLVDSDVVZRUGSURWHFWHGVFUHHQ2QFHWKHVLJQRII SURFHGXUHLVFRPSOHWHGHDV\WRIROORZRQVFUHHQSURPSWPHVVDJHVWKHVRIWZDUHZLOOUHFRUGWKH 5HDO7LPH&ORFN VWLPHDQGGDWH7KHVLJQRIIVFUHHQZLOOQRORQJHUEHGLVSOD\HGLQDQ\VXEVHTXHQW HQWULHVLQ6\VWHP6WDWXVVFUHHQ2QO\WKH'DWHDQG7LPHRIV\VWHPVLJQRIIZLOOEHVKRZQDVUHIHU HQFH$OOIXWXUHGDWDJDWKHULQJZLOOVWDUWIURPWKLVGDWHDQGWLPH
43 7KH6\VWHP6WDWXV6FUHHQVFRQWDLQWKHIROORZLQJGDWDZKLFKLVXSGDWHGUHDOWLPH SYSTEM STATUS INSTALLED HOURS OPERATING HOURS ON UPS OPERATING HOURS ON BYPASS BACKUP TIME 0H 0H 0H 5 H 50 M 18 S SIGN OFF DATE 10/30/01 NEXT EXIT 7KH6LJQ2II'DWHVHJXHVWR6LJQ2II7LPHDQGEDFNHYHU\VHFRQGV SYSTEM STATUS MANUAL XFERS 0 MANUAL REXFERS 0 ALL XFERS 0 ALL REXFERS 0 SIGN OFF DATE 10/30/01 NEXT PREV EXIT
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µLVDFNQRZOHGJHGLWLVVWDPSHGZLWK57&WLPHDQGGDWH7KLVVWHSPXVWEH SHUIRUPHGE\/*6SHUVRQQHO7KHVRIWZDUHZLOONHHSWUDFNRIWKHHODSVHGKRXUVIURPWKDWSRLQWRQ E\VXEWUDFWLQJWKHFXUUHQWWLPHDQGGDWHIURPWKHVLJQRIIWLPHDQGGDWH $FFXPXODWHG2SHUDWLQJ+RXUVRQ836 :LWKRXWSXWFRQWDFWRUFORVHGDQGORDG.9$JUHDWHUWKDQVRIWZDUHDFFXPXODWHVRSHUDWLQJKRXUV WKDWWKHORDGLVVXSSRUWHGE\836 $FFXPXODWHG2SHUDWLQJ+RXUVRQ%\SDVV :LWKE\SDVVFRQWDFWRUFORVHGDQGORDG.9$JUHDWHUWKDQVRIWZDUHDFFXPXODWHVRSHUDWLQJKRXUV WKDWWKHORDGLVVXSSRUWHGE\%\SDVV
45 $FFXPXODWHG%DFNXS+RXUV :LWK%DWWHU\EUHDNHUFORVHGDQGEDWWHU\GLVFKDUJHFXUUHQWJUHDWHUWKDQUDWHG,EDWWVRIWZDUH DFFXPXODWHV+RXUVRUIUDFWLRQRIKRXUVLHWKDWWKHORDGLVVXSSRUWHGE\WKHEDWWHU\V\V WHP,EDWW!5DWHG.:9EDWW $FFXPXODWHGRI%URZQ2XWV $Q,QSXW8QGHUYROWDJHµFRQGLWLRQPXVWH[LVWIRUPRUHWKDQPLQXWHV'XULQJWKLVWLPH,QSXW /LQH)DLOµ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µDODUPIURP836&836&RQ WUROERDUG $YHUDJH/RDG 5XQQLQJDYHUDJHRI.9$VDPSOHVRYHUVHFRQGV
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
48 3.4.2 Alarms Summary Alarm TRN Figure 109 Summary Alarm in Active Position Screen ALARM / FAULT NAME L D F E DELAY Y Y N Y ON BATTERY Y Y Y Y 0 0 INPUT CONTACT #1 Y Y Y Y 0 0 INPUT CONTACT # 2 Y Y Y Y 0 0 INPUT CONTACT # 3 Y N Y Y 0 0 INPUT CONTACT # 4 Y Y Y Y 0 0 UP DOWN EXIT DESCRIPTION: L - Latching...D - Dial... Figure 110 Summary Alarm Editing Screen LATCHING NO DIAL NO FREEZE NO EVENT LOG NO SUMMARY SAVE & EXIT CANCEL Operation 83
49 :KHQWKH1HZ$ODUP6\VWHP6XPPDU\$ODUPRU0RGXOH6XPPDU\$ODUPLVDFWLYDWHG\RXFDQ JHWPRUHLQIRUPDWLRQDWWKH2SHUDWRU'LVSOD\3DQHOWKURXJKDUHPRWHWHUPLQDORUDPRGHP)RU IXUWKHULQIRUPDWLRQVHH6HFWLRQ &RPPXQLFDWLRQ,QWHUIDFHV
50 7KHDODUPPHVVDJHDUHDGLVSOD\VWKHDODUPFRQGLWLRQVWKDWDUHSUHVHQWZLWKLQWKH836V\VWHP7KH WDEOHEHORZVKRZVWKHGHIDXOWYDOXHVRIPDVNVIRUHDFKDODUPIDXOWWKHPHDQLQJRIWKH$ODUPDQG SRVVLEOHFRUUHFWLYHDFWLRQV 7KHIROORZLQJLQIRUPDWLRQDSSOLHVWRWKHWDEOH
51 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
52 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
53 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
54 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
55 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latc h Dial Mas k Freez e Even t Log Meaning and Corrective Action(s)
56 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
57 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
58 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
59 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
60 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
61 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
62 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
63 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
64 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s)
65 Actual Alarm/fault Name Displayed On Front Panel Description of Alarm/ Fault Fault Or Alarm Latch Dial Freeze Event Log Meaning and Corrective Action(s) Remote Alarm Status Panel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µDODUPLVQRWLQGLFDWLQJ 7LPHWR2YHUORDG7UDQVIHU'XULQJDQRYHUORDGFRQGLWLRQWKHWLPHUHPDLQLQJEHIRUHWUDQVIHU LQVHFRQGVLVGLVSOD\HGDWWKHERWWRPRIWKHORDGEORFN
66 3.5 Communication Interfaces TRN RS-232 Port: Local Reporting Terminal TRN TRN Table 7 Service Terminal Command Summary Command Description? OPS Reports a command listing (same as HELP?) OR provides help with specific commands. AA? OPS Reports active alarms. AF? OPS Reports active faults. DATE? OPS Reports the current date. EL? OPS Reports entire event log, most recent on top. HELP? OPS Reports a command li sting (same as?) OR provides help with specific commands. HL? OPS Reports the entire requested history log (comma delimited) if frozen, from oldest frame to newest. SPT? OPS Reports setpoints for group number. SR? OPS Reports active status reports. TIME? OPS Reports the current time in military format. UPMDR? OPS Reports metering data using real values. TRN TRN Operation 101
OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]
OPERATING MANUAL PCC Controller (PCC-01 and 1-149160G) [PCC-01 shown] www.unipowerco.com 2018 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com
More informationAPC BC300 Series 40kW 208/450/480V User Guide
APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank
More informationTECOM SYSTEMS NETWORK MASTER
TECOM SYSTEMS NETWORK MASTER The Tecom Network Master is a cost effective, Dialler Receiver and Direct Line Network Master combined in a single modular unit. HARDWARE The unit consists of a 3RU, 19 inch
More informationDigiplex System V2.14 / V2.2ACC. Control Panel Programming Guide
Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple
More informationTYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM
2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40
More informationUltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW
12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes
More informationDiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm.
DiaLog Elite 1 Prog Remote Monitoring, Control and 2 Run Alarm Notification System 5 SpkrPh 0 Status # Enter Quick Reference Guide Ack Clear Arm Reset Disarm Bksp Home Antx, inc. 2008 RUN Mode Commands
More informationSmart thermostat with Humidification/De-humidification control
x Smart thermostat with Humidification/De-humidification control Enter/Confirm Scroll Right = Increase Left = Decrease Back/Cancel TABLE OF CONTENTS Everyday Use 1. Adjusting Temperature...3 2. Adjusting
More informationCONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH
CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source
More informationSpa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)
Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) P.N. 7876C (export) February 12, 2015 For Spas equipped with BP2100, BP6013 controllers and Spa Touch panel. Spa
More informationDryer Controller M720
User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,
More information20 Light Remote Annunciator
Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator
More informationEasyTronic III MANUAL SERVICE
rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard
More informationModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.
ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page
More informationA36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS
SCADA INTERFACE INSTRUCTIONS - OPTION 21S - FOR A36D/TPSD SYSTEMS with option 500 and 550. A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE OPTION 21S INSTRUCTIONS This manual is valid for A36D/TPSD Chargers
More informationUser Manual. Dryer Controller M720
User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009
More informationSeries 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.
MISSION CRITICAL Air Conditioning Systems Series 9 Commissioning Checklist S9-CL2017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 S9-CL2017.doc Commissioning
More informationSpa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)
Spa Touch Control Panel with 2000, 2100 controllers (Spa Owner s Manual insert) P.N. 7876B February 11, 2015 For Spas equipped with BP2000, BP2100 controllers and Spa Touch panel. Spa Touch Control Panel
More informationFire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96
Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response
More informationGalaxy Pulsar Plus Controller Family Troubleshooting Table with SMNP Traps
Critical Power Product Manual Galaxy Pulsar Plus Controller Family Troubleshooting Table with SMNP s This document supplements CC848815341 Galaxy Pulsar Plus Controller Family Product Manual r07. Service
More informationInstructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C
Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C 1. General The hand-held micro terminal is used for setting the motor parameters of the SILVER C. 2. Installation
More informationAll-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160
All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com
More informationEVO192 v3.0 Fire and Burglary What s New
EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They
More informationVTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL
VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL 1 Operations Manual for the VTI Model itc5000 Heat Tracing Control System Description The VTI Model itc5000 Heat Tracing Control System consists
More informationAGC 200 Advanced Gen-set Controller OPERATOR S MANUAL
Advanced Gen-set Controller OPERATOR S MANUAL Display readings Push-button functions Alarm handling Log list Document no.: 4189340607A SW version 3.5X.X or later Table of contents 1. ABOUT THIS DOCUMENT...3
More informationLa Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual
La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
-961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect
More informationR E C T I F I E R I N V E R T E R C O N V E R T E R SB7
SCR Battery Charger Product Specifications Description The is RIC Electronics premiere SCR battery charger/rectifier. The provides power to critical DC loads through a wide range of outputs and is engineered
More informationPeak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.
Peak Partners Web-Programmable Thermostat Homeowner s Manual Look inside for a complete guide to the setup and operation of your new thermostat. Table of Contents Step 1: Getting Started...4-6 A. Thermostat
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)
More informationINSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.
INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More informationFLOW CONTROLLER TYPE S/601
Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This
More informationVersion 1.03 January-2002 USER S MANUAL
Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...
More informationTri-Stack Smart System
Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and
More information1.1 Remote Annunciator Controller (RAC) using the one ATC-300+ connected via RS-485 network.
Remote Annunciator Controller (RAC) Instruction Sheet for Automatic Transfer Switches (ATS) Revision: 01 IB01602085E 1.1 Remote Annunciator Controller (RAC) using the one ATC-300+ connected via RS-485
More informationINSTALLATION MANUAL & PROGRAM RECORD SHEET
INSTALLATION MANUAL & PROGRAM RECORD SHEET TABLE OF DESCRIPTION CONTENTS PAGE WIRING MANUAL 2-6 MENU CHART 7 INSTALLER FUNCTIONS 8 MENU 1 SYSTEM TIMES 9 MENU 2 ZONE CONFIGURATION 10-14 MENU 3 SYSTEM OPTIONS
More informationDL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL
DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND
More informationRANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL
RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE
More informationIT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.
IT801 Thermostat User s Manual The complete guide to the set up and operation of your new smart Wi-Fi thermostat. The smart Wi-Fi thermostat system learns your comfort preferences, then finds opportunities
More informationRANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL
RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More information2000 Series. Program Entry Guide. Control Panels
2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control
More informationILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING
ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING THE ILLUMINATOR ILLUMINATOR SERIES IE The Illuminator Series IE is an interruptible lighting inverter. It transfers to inverter mode (battery
More informationInstallation Instructions
NX-148E-RF LCD Touchpad with Receiver 466-2198C February 2006 Copyright 2006, GE Security Inc. Contents Product summary 1 Installation 1 Transmitter programming 2 Touchpad programming 5 Reference tables
More informationSoft Start Series MP700 Solid State, Reduced Voltage
Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s
More informationA36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS
SCADA INTERFACE INSTRUCTIONS - OPTION 21Q - FOR A36D/TPSD SYSTEMS with 500 and 550 option. A36D/TPSD Modbus TCP SCADA INTERFACE OPTION 21Q INSTRUCTIONS This manual is valid for A36D/TPSD Chargers equipped
More informationAdaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV
CyCLO User Guide Version 2.00 19 th December 2017 REV 2.00 1 Contents 1. Hardware... 3 1.1. Introduction... 3 1.2. Electrical Specification... 3 1.3. Board Overview... 4 1.4. Electrical Installation...
More informationDC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1
DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove
More informationPowerWizard. Level 1.0 & Level 2.0 Control Systems Training
PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts
More informationSCAN200E USER S MANUAL
SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We
More informationPROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX
PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal
More informationDS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel
DS9400 Series EN Release Notes for Firmware V2.07 Fire Alarm Control Panel DS9400 Series Release Notes for Firmware V2.07 Trademarks Trademarks Gentex is a trademark of Gentex Corporation, Fire Protection
More informationThe ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features
990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has
More informationUser s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas
User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5
More informationIce Rink (Single and Dual Configurations) Custom Control Features
& M&M Refrigeration, Inc. Computer Control System Ice Rink (Single and Dual Configurations) Custom Control Features REVISION DATE DESCRIPTION - 4/20/05 Original release. A 09/21/98 Update Chiller Pump
More informationAPS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES
APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED
More informationBSR Addressable Fire Detection control panel. Installation operation manual
BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents
More informationSilcon DP300E Series 480V kVA User Guide
Silcon DP300E Series 480V 120 160kVA User Guide Copyright 1999 APC Denmark A/S Due to continuous product development information given in this manual is subject to change without notice. User Guide Silcon
More informationSymmetra MW Modbus Data Points
Symmetra MW Modbus Data Points Version 0.11.19.05 rev 1 General Information: There are two devices that constitute the Symmetra MW system: the UPS and the EBS. There is a separate point mapping for each
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationFarm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1.
Manual for use and maintenance Farm Hand CCU 111 / CCU 10R Farm Hand Climate Controller HC/MMA/UmGB-2043-01/13 rev 1.8 P/N: 110131 Farm Hand CCU 111, Farm Hand CCU 10R Manual for use and maintenance Revision:
More informationRC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control
O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS
More informationLaptop / PC Programming Manual
Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup
More informationOperational Overview and Controls Guide
DOCUMENT: ECSEQ2-2 EFFECTIVE: 02/26/10 SUPERSEDES: 02/14/07 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)
More informationMYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL
MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TPC VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIADI&O062705 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 7,8
More informationRev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual
026-1501 Rev 5 3-20-03 Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS
More informationMR-2602 Two Zone Fire Alarm Control Panel
MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...
More informationRCS Residential Control Systems Inc.
RCS Residential Control Systems Inc. Model TZ16 Z-Wave Communicating Thermostat with Rev P HVAC Control Unit INSTALLATION AND OPERATION MANUAL DCN: 141-00882 Rev 02 5/18/06 This manual applies to the following
More informationSOFTWARE VERSION 2.20 CONTROL PANEL RESET:
-961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3
More informationINSTALLATION & OPERATING MANUAL
INSTALLATION & OPERATING MANUAL ACC Extended (ACX) Controller www.unipowerco.com 2017 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com
More informationINDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...
GUIDE MANUAL INDEX 1- Introduction...5...5...6 4- The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops...7 4.2- The Control Panel 4 and 8 Loops...9 5- Installation Guide...10 5.1- Pre-Installation
More informationCA60Plus. Installation manual
CA60Plus Installation manual WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire
More informationMANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS
MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS Starting Serial No. "LH" This manual provides General Information, Installation, Operation, Maintenance and System Set-Up
More informationEvent Monitoring Device (EMD)
Event Monitoring Device (EMD) DRK-S701 INSTALLATION AND OPERATION MANUAL VERSION 2.2 - NOVEMBER 2015 PART NUMBER DRAM-BOOK DO NOT DISCARD! Contents Description Page Introduction/Features 2 Controls and
More informationAS950 REFRIGERATED SAMPLERS
AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
-961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)
More informationContact ID as of 2/2/2015
Contact ID as of 2/2/2015 100 Medical Zone A non-specific medical exists 101 Personal Emergency Zone Emergency Assistance request 102 Fail to report in Zone A user has failed to activate a monitoring device
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationOperator: Save these instructions for future use!
WHITE-RODGERS 1F83-51 Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL
More informationDOOR MONITORING/DURESS SYSTEM
SECTION PART 1 - GENERAL 1.1 RELATED SECTIONS A. Comply with the requirements of Section 27 05 00 Common Work Results for Communications. 1.2 DEFINITIONS A. Not used. 1.3 DESCRIPTION OF SYSTEM: A. Provide
More informationPowerLogic ION Setup Meter Configuration Software Configuration Guide
PowerLogic ION Setup Meter Configuration Software Configuration Guide 70002-0293-03 12/2010 Conventions Used in this Manual This section describes the symbols and terminology used in this guide. Symbols
More informationCELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL
Operation Manual Celltrol II Bioreactor Control System Page 1 of 33 Table of Contents 1) Introduction... 3 1.1) Scope of Document... 3 1.2) Control System Overview... 3 1.3) Introduction to Celltrol II...
More informationFlopurge TS. Operation Manual
Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com
More informationEL-OEM-3 OEM Packaged Voltage Data Logger
OEM Packaged Voltage Data Logger ORDERING INFORMATION Standard Data Logger (Data Logger only. EasyLog software available from ) EL-OEM-3 FEATURES PCB Mounted (2.54mm pitch, header sockets) 0-2.4 Volt d.c.
More informationSOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)
-961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3
More informationAS950 PORTABLE SAMPLERS
AS950 PORTABLE SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Portable Sampler makes programming,
More informationMAIN MENU/HOME SCREEN OVERVIEW
s Sensor (S11) 3038 µs/cm 77.1 F Generic AI (S21) 30.5% Generic AI (S22) 37.9% List of possible s: Contacting Conductivity Electrodeless Conductivity Temperature ph ORP Disinfection Generic Transmitter/AI
More informationi.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A
i.c³ User Guide For Helmer i.series Ultra-Low Freezers 360175-A/A Document History Revision Date CO Supersession Revision Description A 18 APR 2014* 9275 n/a Initial release. * Date submitted or change
More informationMG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide
MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4 Programming Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com
More informationProducts no longer available
Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control
More informationBURGLAR ALARM PANEL BS-468
BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced
More informationZoneSense PLUS. Fire Alarm Control Panel (AS4428.1) Operation & Programming MAN
ZoneSense PLUS Fire Alarm Control Panel (AS4428.1) Operation & Programming MAN 1564-2 Table of Contents SECTION... Page No Responding to an Alarm... 1 1 Introduction... 2 2 Controls Front Panel... 2 2.1
More informationOT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems
OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL Technicold Marine Systems www.technicold.com Technicold by Northern Lights 1419 W. Newport Center Drive Deerfield Beach, FL 33442 Tel:
More informationImportant Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.
1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input
More informationTEMPERATURE CONTROL MODULE MODEL R3-TC2
INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...
More informationD8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide
System Reset Trou ble Silence Ala rm Silence Manual Ala rm ENTER NO YES Letters Numb ers Keyword Radionics System Reset Trouble Silence Alarm Silence Manual Alarm ENTER NO YES Le ters Numbers Keyw ord
More informationRemote NAC Power Supply D7038
Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus
More informationS F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu
GB D S F IT 6" / 8"HES Quick Installation Guide franklinwater.eu Summary Page English 5-19 Deutsch 25-39 Svenska 44-60 French 63-81 Italian 84-101 GB 6" / 8"HES Quick Installation Guide franklinwater.eu
More informationILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING
ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING ALSO AVAILABLE FROM MYERS POWER PRODUCTS: ILLUMINATOR SERIES CIII 4.8 kva TO 50 kva THREE PHASE ILLUMINATOR CM 500 VA TO 2000 VA SINGLE PHASE
More information