1 Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)

2 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog / digital converter core processor for fast performance and provide reliable and stable results. Dual rows of digits LED display gives clear and simple read outs of present value and set value. Operating by buttons platform and user have ease of usage and user-friendly interface PT-5 (x) PT-51 (x9) High Accuracy, High Sampling Rate Sampling rate of 5 times per second (equivalent to 0.2sec per sampling) enables the controller to achieve high accuracy readings and accurate operations. PID Control PID control provides fast and stable process control that minimizes the transition period and overshoot. Thereby, enhancing the effectiveness of the temperature control process. Auto-tuning Artificial intelligence technology enables the controller to calculate the most efficient parameters to suit each and every application, thereby increasing the efficiency of the process to the maximum. PT-50 (9x) PT-50 (2x2) PT-550 (9x9) Temp. SV PID Time Auto Tuning Sensor Break Alarm: If the temperature sensor malfunction / break, an alarm figure will be displayed on the panel to notify users. Heating / Cooling Bi-directional Control Enables the user to select between both heating and cooling processes, reduces inconveniences of single direction control methodology and reduces inventory Multi-inputs Function Accept 2 types of thermocouple inputs and 1 type of RTD input. Convenience of usage. Digital Filter Embedded digital filter function eliminates from interference signals to approach stabilizes control. Switching Power Supply Accepts 0 ~ 20VAC, 50/0Hz power supply, able to prevent controller from being affected by interferences due to ripples in power supply. 1 Tel. +1 (0)5 222 Fax +1 (0) F lnet ek

3 PRODUCT SPECIFICATIS CTROL FUNCTI SIGNAL INPUT Control Method Fraction Value Integral time Differential time Alarm / Output Hysteresis setting Sampling Interval /, PID 0~999 0~999 0~999 0~999 C 0.2s Signal Input Range Accuracy Thermocouple RTD K J PT0-99~999 C -99~999 C -99~50 C 0.5% 1digit 0.5% 1digit 0.5% 1digit ALARM FUNCTI Alarm Types Set Value Alarm Output Action Method Signal Output Absolute Value Alarm 0~99s SPST, A-250Vac (Resistance Load) Alarm Activation / De-Activation delay Alarm Relay Output MAIN CTROL PUT Specifications Module Relay Model Pulse Output (SSR) Analog (Re-transmission) SPST- A/250Vac SPDT 5A/250Vac SPDT 5A/250Vac 0/12Vdc (NPN) Max. ma ~ ma 0~Vdc Min.00 SPDT 5A/250Vac SPDT 5A/250Vac 1 Tel. +1 (0)5 222 Fax +1 (0)

4 PRODUCT SPECIFICATIS STANDARD SPECIFICATIS Power Supply Power Consumption Input Resistance Input Compensation Digital Filter International Standard Settings Range Digit Size Model Display PV (red) SV (green) 0~20Vac, 50/0Hz VA > 1M -99~999 C ~0 Times CE -99~999 C DISPLAY digit of segment display, Accuracy 0.5% 1 digit 0." 0.9" 0.1" 0.5" 0.5" 0.2" 0.2" 0." 0." 0." OPERATING & STORAGE ENVIRMENT Operation Temperature Operation Humidity Storage Temperature STRUCTURE Installation Casing Material Dimensions Colour Protection Rating 0~50 C ~5%RH - ~0 C Panel mounted using 2 locking clips Plastic Refer to page 1 and 1 Black 5 IP-5 50 IP-5 51 IP-5 50 IP IP-5 LED Indicators Digit Size Display Control Output Model Alarm Output Celsius Display Fahrenheit Display X 2 X 2 X 2 X 2 X 2 BLACK PROTECTI Memory Retention EEPROM 15 Tel. +1 (0)5 222 Fax +1 (0)

5 DIMENSI / PANEL CUT & WIRING DIAGRAM DIMENSI / PANEL CUT & WIRING DIAGRAM PT-5:mm(W) x mm(h) x 1mm(D) PT-5-S 1 PT-5-S PT-5-S 2 PT-5-S Relay Output 12Vdc ~ma Output 0~Vdc Output Voltage pulse 55 min. 12Vdc 1 DC~mA 1 0~Vdc min. RTD A TC ~ 20Vac { b B ALM 1 ALM PT-50:9mm(W) x mm(h) x 92.5mm(D) ALM min. B b A RTD TC ALM1 0~20Vac min. PT-50-S 1 Relay Output PT-50-S 12Vdc Voltage pulse PT-50-S 2 PT-50-S ~ma Output 0~Vdc Output NC NO COM 12Vdc DC~mA 0~Vdc PT-51:mm(W) x 9mm(H) x 92.5mm(D) PT-51-S 1 PT-51-S PT-51-S 2 PT-51-S Relay Output 12Vdc ~ma Output 0~Vdc Output Voltage pulse 2.5 min. NC NO COM 12Vdc DC~mA 0~Vdc min ALM ALM1 TC 0~20Vac RTD A b B 1 Tel. +1 (0)5 222 Fax +1 (0)

6 DIMENSI / PANEL CUT & WIRING DIAGRAM DIMENSI / PANEL CUT & WIRING DIAGRAM PT-50:2mm(W) x 2mm(H) x 0.5mm(D) PT-50-S 1 PT-50-S PT-50-S 2 PT-50-S Relay Output 12Vdc ~ma Output 0~Vdc Output Voltage pulse 2 NC 1 NO 15 COM Vdc 1 2 DC~mA 2 2 0~Vdc 2 90 min min. RTD TC A b B ALM ALM1 0~20Vac +0. PT-550:9mm(W) x 9mm(H) x 0mm(D) PT-550-S 1 PT-550-S PT-550-S 2 PT-550-S Relay Output 12Vdc ~ma Output 0~Vdc Output Voltage pulse 9 91 NO NC COM 12Vdc DC~mA 0~Vdc 2 min. 9 0~20Vac 1 11 min RTD A b B TC ALM1 ALM Tel. +1 (0)5 222 Fax +1 (0)

7 ORDERING INFORMATI PT-5 -S - Dimension ---x 0---9x 1---x x x9 Input Signal 0---J Type 1---K Type 2---PT0 Control Output 0---None 1---Relay Output 2---~mA DC Output --~Vdc Output --- Voltage pulse (12Vdc)for SSR drive Alarm Output 0---None Set Set Appendix C Termindal protector None (Except 550) Please call for customized specifications Tel. +1 (0)5 222 Fax +1 (0) F lnet ek

8 PT-5XX PT-XX PT-XX Model / Features Available Dimension DIN (mm) 1/1 DIN (*), 1/ DIN (*9), 1/ DIN (9*), /1 DIN (2*2), 1/ DIN (9*9) 1/2 DIN (*2), 1/1 DIN (*), 1/ DIN (*9), 1/ DIN (9*), /1 DIN (2*2), 1/ DIN (9*9) Color Black Black Black Control Method On/Off, PID+Auto Tuning+Fuzzy () for confirmation or go info subdirectory On/Off, PID+Auto Tuning+Fuzzy for addition and mode change 1/1 DIN (*), 1/ DIN (*9), 1/ DIN (9*), /1 DIN (2*2), 1/ DIN (9*9) On/Off, PID+Auto Tuning+Fuzzy for mode selection Panel for hundred or abort from subdirectory or hot key for control setting for position shift for function programmed setting PV Display for ten or hot key alarm 1 setting for one or hot key alarm 2 setting Digits in red color 0. " " for PT-5, 0.9 for PT-50, 0.1 " for PT-51, 0.5 " for PT-50, PT-550 for confirmation Digits in red color 0.1" for PT-, 0." for PT-, 0.9" for PT-0, 0." for PT-1, 0.5" for PT-0 & PT-50 for change mode for addition and mode change Digits in red color 0.9" for PT-, 0.51" for PT-0, PT-1, 0.9" for PT-0, 0." for PT-50 SV Display Accuracy Input Compensation Digits in green color Digits in green color 0.2 " for PT-5 & PT-50, 0. " 0.2 " for PT- & PT-0, 0. " for PT-51 & PT-50 & PT-550 for PT-1 & PT-0 & PT-50 Digits in green color 0.2 " for PT-, 0. " for PT-0 & PT-1, 0.55 " for PT-0 & PT-50 Power Supply 0 ~ 20 Vac 0 ~ 20 Vac 0 ~ 20 Vac Operation Temperature 0 ~ 50 C 0 ~ 50 C 0 ~ 50 C Storage Temperature - ~ 0 C - ~ 0 C - ~ 0 C Protection IP5 for PT-5, PT-50, IP5 for PT-, PT-0, PT-550 PT-50 Rating IP5 for PT-50, PT-51 IP5 for PT-, PT-0, PT-1 IP5 Installation Panel Mounted Panel Mounted Panel Mounted Memory Retention EEPROM EEPROM EEPROM Signal Input Thermocouple K, J, PT0, JPT0 Thermocouple K, J, R, S, B, E, N, T, PT0, JPT0, linear current, voltage Thermocouple K, J, R, S, B, E, N, T, PT0, JPT0, linear current, 0-V 0.5%FS 1 digit 0.%FS 1 digit 0.%FS 1 digit -99 ~ 999 C -99 ~ 9999 C -99 ~ 9999 C Tel. +1 (0)5 222 Fax +1 (0)

9 Model / Features PT-5XX PT-XX PT-XX Setting Range -99 ~ 999 C -99 ~ 9999 C -99 ~ 9999 C Digit Filter 0 times Fixed 1 ~ 50 times 1 ~ 0 times CTROL FUNCTI Fraction Value Integral Time Differential Time 0 ~ ~ ~ 999 Alarm / Output Hysteresis setting 0 ~ 999 Sampling Interval 0.2 second 0.25 second 00 ms Output Control Cycle 0 ~ 999 second 0.5 ~ second 0.1 ~ second ALARM FUNCTI Absolute Value Alarm, Deviation Alarm Absolute Value Alarm, Deviation Alarm, Area Alarm Absolute Value Alarm, Deviation Alarm, Area Alarm Alarm1 Mode: Alarm1 Operation 0 0 Absolute-value upper-limit ED1=0;H=HI : SV : Alarm Setting Value : Hysteresis Setting Value ( ) ( ) Deviation high alarm ( ) : SV : Alarm Setting Value : Hysteresis Setting Value ( ) ( ) Deviation high alarm ( ) 0 0 Absolute-value lower-limit ED1=0; H=LO Deviation high alarm ( ) Deviation low alarm ( ) Deviation high alarm ( ) Deviation low alarm ( ) Alarm Types 0 0 Deviation low alarm ( ) Deviation low alarm ( ) Upper-limit(deviation) ED1=1;H=HI Deviation high/low alarm ( ) Deviation high/low alarm ( ) SV SV Lower-limit(deviation) ED1=1;H=LO SV SV Band alarm ( ) Process high alarm ( ) Process low alarm ( ) Band alarm ( ) Process high alarm ( ) Process low alarm ( ) Sensor error alarm ( ) Set alarm while sensor break or out of measuringrange. Delay Time 0 ~ 99 second 0 ~ 99 second 0 ~ 99 second Alarm Output SPST-, 5A/ 250Vac (Resistance load) x 2 Max. SPST-, A/ 250Vac (Resistance load) x 2 Max. SSPST-, 5A/ 250Vac (Resistance load) x Max. Include in Main and Auxiliary Output Action Method Direct / Reverse Direct / Reverse Direct / Reverse CTROL PUT Main Control Output x 2 Max. Relay Output (SPDT for PT-50, PT-51, PT-550 1) Pulse Output, Analog Relay Output (SPDT for PT-0, PT-1 1) Pulse Output, Analog ( Re-transmission ) Relay Output(All SPST) Pulse Output, Analog ( Re-transmission ) Modulize Output None None Yes Auxiliary Control Output x 2 Max. None None Relay Output(All SPST) Pulse Output, Analog ( Re-transmission ) Tel. +1 (0)5 222 Fax +1 (0)

10 Model / Features OTHER FUNCTIS Temperature Sensor Break detection PT-5XX PT-XX PT-XX Yes Yes Yes Heater Feedback Irregularities Detection No No Yes SV Remote Setting No No Yes Parameters Lock Password Protection Yes Yes Bar graph Display No No Yes Ramp Soak Setting No No Yes Event Function No No Yes Communication Interface No RS5 RS5 Communication Protocol No ModBus RTU or ASCII ModBus RTU or ASCII Approval CE CE, UL pending CE, UL 21 Tel. +1 (0)5 222 Fax +1 (0) F lnet ek

11 0-PT-B0-EP, 0/1/11 Tel. +1 (0)5 222 Fax +1 (0)

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable

More information

UDC 700 Universal Digital Controllers and Indicator Specifications

UDC 700 Universal Digital Controllers and Indicator Specifications UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY600 (96mm X 48mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma) TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4

More information

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY900 (96mm X 96mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

MC-5 Series Micro Processor Temperature Controller

MC-5 Series Micro Processor Temperature Controller MC-5 Series Micro Processor Temperature Controller Application Plastic, rubber, equipment Injection molding machinery Extruding machinery Mold temperature controllers Vacuum forming Blow molding (Thermo

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

+ A B V B NO NC V COM PV PV

+ A B V B NO NC V COM PV PV + - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC

More information

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

TC515 and TC600 Installation Manual. a Winters company

TC515 and TC600 Installation Manual. a Winters company THERMOLINE TEMPERATURE CONTROLLERS TC515 and TC600 Installation Manual a Winters company Guarantee 12 months Congratulations on the purchase of this new product. Special care with the design, workmanship

More information

TEMPERATURE CONTROL MODULE MODEL R3-TC2

TEMPERATURE CONTROL MODULE MODEL R3-TC2 INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...

More information

UDC100 Universal Digital Controller Specifications

UDC100 Universal Digital Controller Specifications UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

SX65 and SX75. Electronic process controllers

SX65 and SX75. Electronic process controllers SX65 and SX75 Electronic process controllers A combination of simplicity and sophistication... The SX range of process controllers from Spirax Sarco has been designed after carefully considering both technical

More information

CN4800 Series CONTROLLER

CN4800 Series CONTROLLER CN4800 Series CONTROLLER Operator's Manual PV SV OUT1 OUT2 ALM1 ALM2 SEL M1791/0502 Contents I. PREPARING THE OPERATION... 4 1. THE BASIC INSTALLATION PROCEDURE... 5 2. CHECK OF SPECIFICATIONS... 6 2.1

More information

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module

More information

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock. Temperature Controller KXN Series INSTRUCTION MANUAL Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product. Please check whether the prouduct you purchased is the exactly same as you ordered. Before using

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 11/98 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 & UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers which

More information

370, boulevard de Balmont LYON Tel Fax Web:

370, boulevard de Balmont LYON Tel Fax Web: AUTOMATISME Régulateurs de température delta DELTA développe, dessine, fabrique des composants et des équipements électronique pour les plus importants constructeurs internationaux. Fort de ses 30.000

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 48VTR Product Info Page Instruction Manual English / Español

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

DC1000 Series Digital Controller Product Manual August 2005

DC1000 Series Digital Controller Product Manual August 2005 DC1000 Series Digital Controller Product Manual 51-52-25-113 August 2005 Industrial Measurement and Control Copyright, Notices and Trademarks Printed in Taiwan - Copyright 2005 by Honeywell Revison 1 -

More information

Model 96VTR ¼ DIN Process Controller

Model 96VTR ¼ DIN Process Controller 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 96VTR Product Info Page INSTRUCTION MANUAL Model 96VTR ¼ DIN

More information

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as

More information

4TEMPERATURE CONTROLLER

4TEMPERATURE CONTROLLER Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and

More information

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485 Select Option Device Wise Device/Group HumiLog Y-Axis Text Show/Hide Ledgends MIN MAX Scale Y Max 08-05-2015 15:17:59 PV_C PV_RH Color default default Graph Refresh Interval 2 Set Interval PV Low Alarm

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

General Specifications

General Specifications General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions

More information

Specification , July 2015

Specification , July 2015 Technical Information PrecisionLine Controllers EDC21 / EDC22 / EDC23 EASYSET DIGITAL CONTROLLERS Specification 51-52-3-48, July 215 Introduction The EDC21, EDC22 and EDC23 controllers provide precise

More information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F Temperature Controller 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to ±0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

Example of Applications and Parameter Functions

Example of Applications and Parameter Functions PX-series digital temperature controller Example of Applications and Functions ECNO:1158 I. Example of Applications 1 Controlling both heating and cooling with a single controller Only one controller is

More information

MICRO CONTROLLER S Z SERIES

MICRO CONTROLLER S Z SERIES Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure

More information

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Instruction manual for DIN rail mounting type indicating controller DCL-33A Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

Instruction manual Temperature Controller KT7

Instruction manual Temperature Controller KT7 Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure

More information

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 Jun. 2007 Auber Instruments, 730 Culworth, Alpharetta, GA 30022 www.auberins.com e-mail: auberins@gmail.com Tel: 404-291-6298 WARNING

More information

/8 DIN Level Indicator

/8 DIN Level Indicator Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included

More information

Instruction manual Micro-computer based digital indicating controller

Instruction manual Micro-computer based digital indicating controller Instruction manual Micro-computer based digital indicating controller JCS-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual.

More information

INSTRUCTION MANUAL Micro-computer based digital indicating controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02 Temperature Controller Fuzzy Self-tuning Temperature Controller with Advanced PID (2-PID) Control DIN-size: 6 x 6 mm (E5AJ), 2 x 2 mm (E5BJ), 4 x 4 mm (E5CJ), 4 x 6 mm (E5EJ) Fuzzy self-tuning and Auto-tuning

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTI MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E6 28.8 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

VERTEX F4 Instruction Manual

VERTEX F4 Instruction Manual VERTEX F4 Instruction Manual 02/2018 The VERTEX F4 controller 1/16 DIN is our LOW COST yet HIGH SPEC controller. Configurable on input between various thermocouples from the keypad by the user or when

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A Preface Thank you for the purchase of our Microcomputer based Temperature Indicating Controllers JCD-13A or

More information

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

Table of Contents SECTION PAGE

Table of Contents SECTION PAGE Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................

More information

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER MODEL AL3 7 5 - AL3000 series conforming to CE, UL and CSA are 100mm multi-point type hybrid recorders with a simultaneous display of multi-channel

More information

Temperature Controller

Temperature Controller E5AN Temperature Controller Temperature Controller OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku,

More information

Selection Guide To Temperature Controllers

Selection Guide To Temperature Controllers Selection Guide To Temperature Controllers E5 J Temperature Controllers Fuzzy Self-tuning with Advanced PID for Optimum Temperature Control No Tuning Required E5 J requires NO tuning after initial setting.

More information

HTC-915-CONT. Heat-Trace Control system

HTC-915-CONT. Heat-Trace Control system Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100 INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

Installation Manual Tracker 221

Installation Manual Tracker 221 Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

GCS-300 No.GCS31E

GCS-300 No.GCS31E INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller GCS-00 No.GCS1E 200.0 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates

More information

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER 1 DCL-A DC No.DCLDCE1 2007.01 Thank you for purchasing our DIN rail mounting type indicating controller DCL-A DC. This manual contains instructions

More information

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER KL4000 Series hybrid recorders realize simple and easy operation as analog recorders. Not only can each measured value be read from the custom

More information

DIGITAL INDICATOR JIR-301-M

DIGITAL INDICATOR JIR-301-M DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when

More information

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module Clavex Plus Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module PC Software Controller with Graphic Display Printer Module Features

More information

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately) Digital Panel Meter Low-cost, High-quality Digital Thermometer with Built-in Microcomputer Compact DIN-size (96 x 48 x 66 (W x H x D)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

eed quality electronic design USER s MANUAL

eed quality electronic design USER s MANUAL eed quality electronic design www.dem-it.com eed www.qeed.it info@qeed.it ANALOG SIGNAL DISPLAY Q-DISP-T USER s MANUAL The displays Q-DISP-T, prepared for mounting on the back panel, 96x48mm, will allow

More information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with

More information

CONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual

CONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual Instruction Manual Micro-controller X Model : PXR5/9 INP-TNPXR5/9-E Head Office -, Osaki -chome, Shinagawa-ku, Tokyo, 4-3 Japan Sales Div. International Sales Dept. No., Fuji-machi, Hino-city, Tokyo, 9-85

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit ABB MEASUREMENT & ANALYTICS DATA SHEET C50 1/16 DIN controller / alarm unit 2 C50 1/16 DI N CON TROLL ER / AL ARM U NIT DS/C 50-E N RE V. M Measurement made easy C50 the 1/16 DIN controller to suit your

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Terwin Instruments Ltd.

Terwin Instruments Ltd. Terwin Instruments Ltd. Temperature PID Controllers MC-x8 OPERATIONAL MANUAL MC 8 / MC 8 / MC 8 MC 8 / MC 88 ( Display unit & Indication lamps ~ =Measured value display =Set value dispaly Alarm output

More information

Universal Input Digital Panel Meter With Bargraph, NA3

Universal Input Digital Panel Meter With Bargraph, NA3 products Panel Panel Meters Digital Universal Input Digital Panel Meter With Bargraph, NA3 Universale input (programmable) Wide voltage, AC/DC control 4 digit, With or without 3/7 colour bargraph Description

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for choosing Delta DTE series temperature controller. Please read this instruction sheet carefully before using your DTE to ensure proper

More information

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL Preface Thank you for purchasing our Digital indicating controller FCS-23A. This manual contains instructions for the mounting, functions, operations

More information

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs TEC2620 Series Non-Programmable Fan Coil Network Thermostat ler and Remote I/O Relay Packs TEC2620H-0, TEC2620C-0, TEC2620H-0+PIR, TEC2620C-0+PIR, TEC2621H-0, TEC2621C-0, TEC2621H-0+PIR, TEC2621C-0+PIR

More information

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction Series SHR-5620 Digital Display Volumetric Meter Operation Instruction Version: 5620-110722 1. Introduction SHR-5620 Digital Display Volumetric Meter,Produced by full-automatic chip mounter with surface

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom Viconics VT7350 Series PIR Ready Fan-coil Controllers General The VT7350 series are PIR Ready low-voltage microprocessor-based fan-coil controllers. Models are available controlling single speed and multi-speed

More information

Digital Heater Element Burnout Detector K8AC-H

Digital Heater Element Burnout Detector K8AC-H Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling

More information

R1000 / R1040 / R1080

R1000 / R1040 / R1080 R1000 / R1040 / R1080 1 Zone Temperature Controller: Heat-only Heating-off-cooling Three-point stepping DIN-Format: 96mm x 96mm / 48mm x 96mm / 96mm x 48mm Description and operating manual ELOTECH Industrieelektronik

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Operating Instructions. For. Alarm Control Module. Model SSR 500

Operating Instructions. For. Alarm Control Module. Model SSR 500 SSR 500 LEVEL CONTROL RELAY MODULE Operating Instructions For Alarm Control Module Model SSR 500 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions

More information