Study on the North China Rural Water Supply Project O&M Cost Standard Rating
|
|
- Kristopher Garrison
- 6 years ago
- Views:
Transcription
1 rd International Conference on Engineering Technology and Application (ICETA 2016) ISBN: Study on the North China Rural Water Supply Project O&M Cost Standard Rating Lei Zhao China Institute of Water Resources and Hydropower Research, Beijing, China Jing Yang Datang Environment Industry Co., Ltd., Beijing, China ABSTRACT: For the purpose of further regulating the set-up standard of rural water supply project operation and maintenance cost, O&M cost accounting method should be identified; with North China plain area as the study target, water supply projects at 722 places are selected randomly for study. On the basis of survey data, multiple regression analysis means is employed to analyze relations between O&M cost and operation cost, annual actual output of water supply, personnel cost, electric tariff and water supply facility O&M frequency, and three O&M calculating models are established. O&M cost check computation has high reliability through personnel cost and electric tariff, operation cost and personnel cost, personnel cost and pump, purification equipment, electromechanical equipment, instrument and meter, valve and transmission and distribution pipe network maintenance frequency to some extent. Meanwhile, three O&M calculating models should be selected flexibly in combination with project conditions in actual application. Keywords: rural water supply project; survey; multiple regression analysis; O&M cost; calculating models 1 INTRODUCTION As a rural water supply project involves many operation and maintenance (O&M) items and costs are hard to be quantified, there are no unified provisions for O&M cost at present. As far as municipal water supply is concerned, with mature water supply system, 2.5% of the project fixed assets are withdrawn as the water supply project O&M cost [1]. For the operation management aspect of the rural water supply project, some areas set up rural water supply project maintenance fund based on their own conditions. Take Henan province as an example, the maintenance fund amount is RMB100, ,000 each county, RMB 0.1~0.2/t water is drawn from water charge of the water supply project as project O&M fund, which basically addresses the routine O&M cost of the rural water supply project [2]. For the rural water supply project O&M cost issue, in line with Chinese actual *Corresponding author: zhaolei_cdte@163.com conditions of rural water supply project, we learnt current drawing methods of O&M cost are mainly fixed limit drawing method, fixed-asset fixed proportion drawing method, and water charge fixed quota drawing method [3]. As some rural water supply projects are limited by natural geographic conditions, topographical and geological conditions and water charge collection difficulty in some areas, rural water supply projects feature high water supply cost and non-implementation of water price [4]. Such being the case, O&M cost has too high or too low problems, whether drawn as per fixed proportion of the project operation cost or as per water charge fixed quota. For the purpose of further identifying accounting method of rural water supply project O&M cost, with North China plain area as the study target, water supply projects at 722 places are selected randomly for study, examples are employed to analyze relations between water supply O&M cost and operation cost and other operation conditions, set forth O&M cost calculating method and establish corresponding calculating models [5]. 1046
2 2 SURVEY ITEMS Survey items of rural water supply projects at 722 places mainly include two aspects of project general and O&M [6]. Detailed survey items have project operation time (time the project is commissioned), water source type (groundwater, surface water), design water supply size (Qd), operation cost (Ecost), water resource charge (Ew), electric tariff (Ee), chemical cost (Ec), personnel cost (Ep), O&M cost (Em), chemical quality test fee (Et), tax fee (Etax), actually collected fee (Ecollect) as well as specially for rural water supply projects - pump maintenance frequency (Fp), purification equipment maintenance frequency (Fpw), electromechanical equipment maintenance frequency (Fem), meter maintenance frequency (Fmeter), valve maintenance frequency (Fvalve), transmission and distribution pipe network patrol frequency (Fpipe), etc [7]. According to design water supply size classification method in the Rural water supply project design specification (SL ) [8], V type water supply projects (design water supply size less than 200m³/d) at 172 places, IVtype water supply projects (design water supply size is 200m³/d~1000m³/d) at 333 places, III type water supply projects (design water supply size is 1000m³/d~5000m³/d) at 206 places, II type water supply projects (design water supply size is 5000m³/d~10000m³/d) at 9 places and Itype water supply projects (design water supply size more than 10000m³/d) at 2 places are selected randomly out of 722 places. On the basis of survey data, O&M cost calculating methods are described and O&M calculating models are established by analyzing relations between O&M cost and operation cost, personnel cost, electric tariff and water supply facility O&M frequency [9]. 3 O&M CALCULATING MODELS As current fixed limit drawing method, operation cost fixed proportion drawing method, and water charge fixed quota drawing method cannot completely describe survey data and cannot cover most water supply projects, O&M cost calculating methods are prepared and corresponding calculating models are established by comprehensively analyzing relations between O&M cost and design water supply scale, actual water supply output, operation cost, electric tariff, personnel cost, and water supply facility maintenance frequency and other parameters [10]. Through overall data analysis and processing of water supply projects at 722 places, we found there are good multiple linear relations between O&M cost and personnel cost and electric tariff, between logarithm-processed O&M cost and operation cost and personnel cost, and between O&M cost and personnel cost and facilities maintenance frequency. Based on that, this essay builds O&M cost calculating model based on personnel cost and electric tariff, O&M cost calculating model based on operation cost and personnel cost and O&M cost calculating model based on personnel cost and facilities maintenance frequency [11]. Detailed analysis is as follows: 3.1 O&M cost calculating model based on personnel cost and electric tariff Through multiple linear regression analysis between O&M cost and personnel cost and electric tariff, it correlation coefficient R2 is 0.636, showing 63.6% of O&M cost data can be explained by changes in personnel cost and electric tariff, and analysis conclusions are in good multiple linear relations; through regression model F test, F=628.17,P=0.000,complies with α<0.05, so this regression equation fitting degree is good and has statistical significance. Multiple linear regression analysis coefficients are shown in Table 1, corresponding standardized residue histogram and normality P-P diagram are shown in Figure 1. As apparent from Table 1, according to test result t of electric charge and personnel fee regression coefficient, its t value is (P=0.009<0.01), (P=0.000<0.01), showing linear fitting result is fairly good. Absolute value of standard coefficient is a parameter reflecting independent variable impact on dependent variable, the larger absolute value, the larger impact of independent variable on dependent variable. Through standard coefficient values of electric charge and personnel fee, standard coefficients are 0.06 and respectively, which shows in relation to electric charge, and personnel fee plays a decisive role. Further, regression coefficients of electric charge and personnel fee are and respectively, and both are positive values, which show project O&M cost increases with increase of electric charge and personnel fee. Table 1. O&M cost calculating model coefficient table based on personnel cost and electricity tariff. Non-standard coefficient Standard coefficient t Sig. Constant Electric charge Personnel fee For standardized residue histogram and normality P-P diagram, if regression standardized residue histogram matches the normality distribution conditions or standardized residue normality P-P diagram points are in a straight line, the established O&M cost calculating model well describes original data. Through Figure 1, regression standardized residue histogram cannot completely matches normality distribution and normality P-P diagram points are not on a straight line, showing O&M cost calculating model based on per- 1047
3 sonnel cost and electric tariff has certain statistical significance, but it can only describe part of original data. (a) Histogram is good and has statistical significance. Multiple linear regression analysis coefficients are shown in Table 2, corresponding standardized residue histogram and normality P-P diagram are shown in Figure 2. As apparent from Table 2, t test result of operation cost and personnel fee regression coefficient show that linear fitting result is fairly good, and project O&M cost increases with increase of operation cost and personnel fee; Through standard coefficient values of operation cost and personnel fee, standard coefficients are 0.25 and 0.34 respectively, which shows both operation cost and personnel fee play a decisive role. Table 2. O&M cost calculating model based on operation cost and personnel cost Non-standard coefficient Standard coefficient t Sig. Constant Operation cost Personnel fee (b) Normality P-P diagram Figure 1. Regression standard residue histogram and Regression equation of O&M cost is Formula (1): (a)histogram Em=0.211Ep+0.031Ee (1) Where, Em, Ee and Ep are maintenance cost, electric charge and personnel fee, and the unit is all RMB/year. As apparent from Formula (1), for the surveyed water supply projects, each water supply project has to draw 21.1% from personnel fee and 3.1% from electric charge, and given fixed annual maintenance fund is RMB as annual O&M cost of that water supply project. 3.2 O&M cost calculating model based on operation cost and personnel cost Through logarithm analysis for overall data of water supply projects at 722 places, we found O&M cost and personnel fee and operation cost have good multiple linear relations, its correlation coefficient R2 is 0.296, showing about 29.6% of can be explained by changes in personnel cost and operation cost; through regression model F test, F=67.997,P=0.000,complies with α<0.05, so this regression equation fitting degree (b)normality P-P diagram Figure 2. Regression standard residue histogram and As apparent from Figure 2, standardized residue histogram basically matches the normality distribution, standardized residue normality P-P diagram points are in a straight line, showing the established O&M cost calculating model has statistical significance, and it is reasonable and feasible, the established O&M cost calculating model based on operation cost and per- 1048
4 sonnel cost well describes original data, with high simulation result reliability. Regression equation of O&M cost is Formula (2): lnem=0.254lnecost+0.340lnep (2) Where, Em, Ecost, and Ep are maintenance cost, operation cost and personnel cost, and the unit is all RMB/year. As apparent from Formula (2), for the surveyed water supply projects, logarithm of water supply project O&M cost at each place is composed of 25.4% of operation cost logarithm, 34% of personnel cost logarithm and fixed constant O&M cost calculating model based on personnel cost and facilities maintenance frequency O&M cost of rural water supply projects is decided by pump maintenance frequency (Fpump), purification equipment maintenance frequency (Fpw), electromechanical equipment maintenance frequency (Fem), valve maintenance frequency (Fv) and transmission and distribution water pipe network patrol frequency (Fp). Before multivariate statistical analysis, descriptive statistics is performed for facility maintenance frequency in the survey and difference of maintenance frequency of all water supply facilities for various rural water supply projects (See Table 3). Table 3 reflects big differences of maintenance frequency of all water supply facilities for various rural water supply projects; for instrument and meter transmission and distribution pipe network maintenance, some water works conduct monthly maintenance as required, but water works only conduct annual maintenance; for water purification equipment, some water works do not conduct water purification facility maintenance; O&M of other facilities also have big differences, showing O&M of rural water supply projects needs further enhancement. Difference in water supply facility maintenance frequency is one of important reasons for differences of O&M cost for rural water supply projects. Through comprehensive analysis for multiple linear regression of O&M cost and pump, purification equipment, electromechanical equipment, instrument and meter, valve and transmission and distribution water pipe network maintenance frequency and other indicators, O&M cost calculating models for dependent variables such as personnel cost and pump, purification equipment, electromechanical equipment, instrument and meter, valve and transmission and distribution water pipe network maintenance frequency are established. For the established O&M cost calculating models, correlation coefficient R2 is 0.712, showing 71.2% of data can be explained by changes in personnel cost and pump, purification equipment, electromechanical equipment, instrument and meter, valve and transmission and distribution water pipe network maintenance frequency; through regression model F test, F= , P=0.000, complies with α<0.05, so this regression equation fitting degree is good. Coefficients of O&M cost calculating model based on personnel cost and facilities maintenance frequency are shown in Table 4, corresponding standardized residue histogram and normality P-P diagram are shown in Figure 3. Table 4 shows t test results of purification equipment maintenance frequency Fpw, electromechanical equipment maintenance frequency Fem, instrument and meter maintenance frequency Fmeter, valve maintenance frequency Fv, and personnel cost Ep, t values are (P=0.001), (P=0.001), (P=0.000), (P=0.000) and (P=0.000) respectively, complies with α<0.05, linear fitting results are fairly good, meanwhile, pump maintenance frequency Fpump regression coefficient t test results show its linear relations are slightly not significant. Table 3. Description of O&M frequency of facilities. Item Min.(time/year) Max.( time/year) Average (time/year) Standard difference SD Coefficient of variation CV Fpump Fpw Fem Fmeter Fv Fpn Table 4. Coefficients of O&M cost calculating model based on personnel cost and facilities maintenance frequency. Non-standardcoefficient Standard coefficient t Sig. Constant Fpump Fpw Fem Fmeter Fv Fpn Ep
5 Through regression standard coefficient, project O&M cost increases with increase in Fpump, Fem, Fv, Fpn and Ep, but decreases with increase in Fpw and Fmeter. Through analysis and comparison of absolute values of standard coefficients, personnel cost Ep plays a decisive role in O&M cost, sequence of other indicators in terms of impact on O&M cost is Fv, Fmeter, Fpw, Fem, Fpn and Ep. corresponding O&M cost accounting formula is shown in Formula (3). Em= Fp Fpw Fem Fmeter Fv Fpn Ep (3) Where, Em and Ep, are maintenance cost, operation cost and personnel cost, and the unit is RMB/year; Fp, Fpw, Fem, Fmeter, Fv and Fpn are maintenance frequency, and the unit is time/year. through regression model F test, F=42.556, P=0.000, complies with α<0.05, so the regression equation fitting degree is fairly good, has statistical significance. Its multiple linear regression analysis coefficient is shown in Table 5, and the corresponding regression standard residue histogram and P-P diagram are shown in Figure 4. Table 5. Coefficients of O&M cost calculating model (improved) based on personnel cost and facilities maintenance frequency. Non-standard coefficient Standard coefficient t Sig. Constant Fpump Fpw Fem Fmeter Fv Fpn Ep (a)histogram (a)histogram (b)normality P-P diagram Figure 3. Regression standard residue histogram and Figure 3 shows that although correlation coefficient R2 is 0.712, histogram of regression standard residue cannot well match normality distribution, and P-P diagram points are not in a straight line, which cannot fully describe original data. To further establish O&M cost calculating models which fully describe original data, logarithmic treatment is made to O&M cost and personnel cost, then multiple linear regression step is repeated, for improved O&M cost and personnel cost, (b)normality P-P diagram Figure 4. Regression standard residue histogram and Table 5 shows that t test results of purification equipment maintenance frequency Fpump, electromechanical equipment maintenance frequency Fem, instrument and meter maintenance frequency Fmeter, valve maintenance frequency Fv, and personnel cost 1050
6 Table 6. O&M cost accounting method summary table. Project type V Type O&M cost calculating model based on personnel cost and electric tariff(cost unit RMB/year) O&M cost calculating model based on operation cost and personnel cost(cost unit RMB/year) O&M cost calculating model based on personnel cost and facilities maintenance frequency(cost unit RMB/year) IV type III type II type I type Em=0.211Ep+0.031Eem lnem=0.254lnecost+0.340lnep lnem=0.173fpump-0.046fpw Fem-0.041Fmeter-0.038Fv Fpn+0.516lnEp Ep, P value is less than 0.01, showing linear fitting result is fairly good; t test results of Fp, Fmeter, and Fv, regression coefficients show linear fitting result is fairly poor. From values of standard coefficient, Ep standard coefficient is 0.527, with the largest effect on O&M cost Em, takes the absolute dominating position, showing personnel cost plays a decisive role in O&M cost, sequence of other indicators in terms of impact on O&M cost is Ep, Epn, Fem, Fpw, Fmeter and Fv. from Figure 4, regression standard residue complies with normality distribution, P-P diagram points of regression standard residue are basically distributed on a straight lie, showing improved O&M cost calculating models fairly well describe original data, with high reliability. Regression equation of O&M cost is Formula (4): lnem=0.173fpump 0.046Fpw 0.117Fem (4) 0.041Fmeter 0.038Fv+0.136Fpn+0.516lnEp Where, Em, Ep, Fpump, Fpw, Fem, Fmeter, Fv, and Fpn are the same as in Formula (3). 4 CONCLUSIONS For water supply projects at 722 places in survey, on the basis of survey data, relations between O&M cost and operation cost, annual actual output of water supply, personnel cost, electric tariff and water supply facility O&M frequency are analyzed, O&M cost accounting methods are described, and corresponding O&M cost calculating models are established. Accounting methods for the above O&M cost are summarized as shown in Table 6. Multiple regression analysis means is employed to establish three calculating models, all with statistical significance, O&M cost check computation has high reliability through personnel cost and electric tariff, operation cost and personnel cost, personnel cost and pump, purification equipment, electromechanical equipment, instrument and meter, valve and transmission and distribution pipe network maintenance frequency to some extent. What is worth mentioning is established O&M cost calculating methods and models for the above analysis have respective advantages and disadvantages and have corresponding scope of application, detailed methods shall be selected flexibly in line with actual project conditions. REFERENCES [1] Shanghai Municipal Engineering Design Study Water Supply and Drainage Design Manual (10) Techno-Economy (Edition 2). Beijing: China Building Industry Press. [2] State Development and Reform Commission, Ministry of Water Conservancy, Ministry of Health, etc. National Rural Drinking Water Safety Project 12th Five-Year Plan [R]. June [3] Beuth Verlag Economic benefits of standards: Summary of results. DIN German Institute for Stand, pp: [4] DTI The empirical economics of standards. DTI Economics Paper. [5] Dracupja, Leeks, Paulsoneg On the statistical characteristics of drought events. Water Resources Research, 16(2): [6] Tian Shougang, Fan Mingyuan Research on coordinated evaluation of district water resources allocation. Proceedings of 2011 International Symposium on Water Resource and Environmental Protection (ISWREP 2011) VOL.01. [7] Wenkun Liu, Yuansheng Pei, Yong Zhao, Weihua Xiao The research of the regional meteorological drought assessment model. Applied Mechanics and Materials, pp: [8] Rural water supply project technical specification (SL ) [S]. China Water Conservancy and Hydropower Press, 2005 [9] ISO Standardization of Economic Benefits - International Case Studies. Beijing: China Standard Press. [10] He Shoukui, Wang Yuanyuan, Huang Mingzhong, The management mode of water users association from the perspective of autonomy, China Rural Water and Hydropower, pp: [11] Zhou Guangan, Zhang Luyang, Sun Jingke Exploration and practice of new pattern for secondary water supply management, China Water & Wastewater, (18):
Design of Humidity Monitoring System Based on Virtual Instrument
Available online at www.sciencedirect.com Procedia Engineering 24 (2011) 759 763 2011 International Conference on Advances in Engineering Design of Humidity Monitoring System Based on Virtual Instrument
More informationExperimental Study on the Effects of Compression Parameters on Molding Quality of Dried Fish Floss
Experimental Study on the Effects of Compression arameters on Molding Quality of Dried Fish Floss Hongmei Xu, Li Zong, Ling Li, and Jing Zhang College of Engineering and Technology, Huazhong Agricultural
More informationInternational Forum on Energy, Environment Science and Materials (IFEESM 2015)
The Comparison and Analysis of Humidity Environment between Floor and Ceiling Radiant Cooling Systems that Combined with Displacement Ventilation Kai SUN 1 a *, Chuan-hui ZHOU 1 1 College of Urban Construction,
More informationState Grid Zhejiang Electric Power Corporation Electric Power Research Institute, Hangzhou, , China
2017 Joint International Conference on Materials Science and Engineering Application (ICMSEA 2017) and International Conference on Mechanics, Civil Engineering and Building Materials (MCEBM 2017) ISBN:
More informationMODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING
MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING V. Vakiloroaya*, J.G. Zhu, and Q.P. Ha School of Electrical, Mechanical and Mechatronic Systems,
More informationHealthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler
Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0232 ISBN: 978-83-7947-232-1 Experimental study of a novel dew point indirect evaporative cooler Wenhua Chen, Zhiwei Zhang, Jiayu Li,
More informationOpen Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System
Send Orders for Reprints to reprints@benthamscience.ae The Open Electrical & Electronic Engineering Journal, 215, 9, 7-14 7 Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning
More informationApplication of the VRV Air-Conditioning System Heat Recovery Series in. Interior Zone and Analysis of its Energy Saving
Application of the VRV Air-Conditioning System Heat Recovery Series in Interior Zone and Analysis of its Energy Saving Qiang Zhang Deying Li Jiandong Zhang Master Student Professor Engineer Key Laboratory
More informationThe Development of Automatic Fire Alarm Standards and Related Products in China
The Development of Automatic Fire Alarm Standards and Related Products in China Hongjun Ding Shenyang Fire Research Institute, Shenyang, China Abstract This paper aims to introduce the development of automatic
More informationEMPIRICAL MODEL SIMULATING RAINWATER HARVESTING SYSTEM IN TROPICAL AREA
EMPIRICAL MODEL SIMULATING RAINWATER HARVESTING SYSTEM IN TROPICAL AREA Thamer Ahmad Mohammad, Abdul Halim Ghazali, Megat Johari Megat Mohd. Noor Department of Civil Engineering, Faculty of Engineering,
More informationAn improved Algorithm of Generating Network Intrusion Detector Li Ma 1, a, Yan Chen 1, b
An improved Algorithm of Generating Network Intrusion Detector Li Ma 1, a, Yan Chen 1, b 1 Department of Information Engineering Guilin University of Aerospace Technology, Guilin China a E-mail: woshiml@sina.com,
More informationEffect of Water and Nitrogen Stresses on Correlation among Winter Wheat Organs
Effect of Water and Nitrogen Stresses on Correlation among Winter Wheat Organs Zhou Xin-yang and Wang Yang-ren * Hydraulic Engineering Department, Tianjin Agricultural University, Tianjin, China, 300384
More informationA Forest Fire Warning Method Based on Fire Dangerous Rating Dan Wang 1, a, Lei Xu 1, b*, Yuanyuan Zhou 1, c, Zhifu Gao 1, d
International Conference on Applied Science and Engineering Innovation (ASEI 2015) A Forest Fire Warning Method Based on Fire Dangerous Rating Dan Wang 1, a, Lei Xu 1, b*, Yuanyuan Zhou 1, c, Zhifu Gao
More information2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures
Available online at www.sciencedirect.com Procedia Engineering 45 (2012 ) 643 648 2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire
More informationOn the choice between the international and China spatial planning. system patterns
On the choice between the international and China spatial planning system patterns Cai Yumei Gao Ping Wang Jing Liao Rong ( China Land Survey and Planning Institution, Beijing, 100035 ) Abstract: National
More informationA Study into the Standardization of Using Fire Detectors in Rail Vehicles for China
Available online at www.sciencedirect.com Procedia Engineering 52 ( 2013 ) 240 244 A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China LIU Xiao-lu *, WANG Wen-qing Shenyang
More informationEFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY
EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY Aivars Aboltins, Janis Palabinskis Latvia University of Agriculture aivars.aboltins@inbox.lv Abstract. The paper describes the results
More informationfor family composition, time allocation of people, ownership and specification of home appliances. This paper first presents the simulation procedure
Validation of an Energy Demand Model of Residential Buildings Yohei Yamaguchi 1*, Yoshiyuki Shimoda 1 1 Graduate School of Engineering Osaka University, S4 Building, 2-1 Yamadaoka, Suita, Osaka, 565-871,
More informationSaying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii
Saying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii Jenny Yaillen, Evergreen Economics Chris Ann Dickerson, CAD Consulting Wendy Takanish and John Cole, Hawaii Public Utilities
More informationExperimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential
More informationResearch on the Monitor and Control System of Granary Temperature and Humidity Based on ARM
Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM Liu Yang 1, Xinrong Cheng 2, Zhijie Jiang 3, and Zhijun Ren 1 1 Engineering College, China Agricultural University,
More informationDesign and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology
Sensors & Transducers 2014 by IFSA Publishing, S. L. http://www.sensorsportal.com Design and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology 1 Liu Ming
More informationBest Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System
International Conference on Civil, Transportation and Environment (ICCTE 201) Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System Pengjie Fan1, a, Caihua Liang1,
More informationA Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths
A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths Xiao Xiao, Tian Deng, Ming Zhu, Shu Wang School of Electronic Information and Communications, Huazhong University
More informationThe Low-Temperature Radiant Floor Heating System Design and Experimental Study on its Thermal Comfort
International Journal of Research in Engineering and Science (IJRES) ISSN (Online): -9364, ISSN (Print): -9356 Volume 4 Issue 1 ǁ January. 16 ǁ PP.56-61 The Low-Temperature Radiant Floor Heating System
More informationSimulation study of evacuation in high-rise buildings
Available online at www.sciencedirect.com ScienceDirect Transportation Research Procedia 00 (2014) 000 000 www.elsevier.com/locate/procedia The Conference in Pedestrian and Evacuation Dynamics 2014 (PED2014)
More informationA TRNSYS Simulation Case Study on Utilization of Heat Pump For both Heating and Cooling
Energy Science and Technology Vol. 3, No. 2, 2012, pp. 84-92 DOI:10.3968/j.est.1923847920120302.397 ISSN 1923-8460[PRINT] ISSN 1923-8479[ONLINE] www.cscanada.net www.cscanada.org A TRNSYS Simulation Case
More informationTHE CHARACTERISTICS ON THE GENERATION OF URBAN FORM OF HANGZHOU COMBINING WITH THE HIGH SPEED URBANIZATION
The 4 th International Conference of the International Forum on Urbanism (IFoU) 2009 Amsterdam/Delft The New Urban Question Urbanism beyond Neo-Liberalism THE CHARACTERISTICS ON THE GENERATION OF URBAN
More informationA design of automatic boiler intelligent alert system based on the wireless AD hoc network
5th International Conference on Computer Sciences and Automation Engineering (ICCSAE 2015) A design of automatic boiler intelligent alert system based on the wireless AD hoc network Shiping Li1, a Maodong
More informationTeaching Landscape Spatial Design with Grading Studies: An Experiment Based on High Fidelity DTM
302 Full Paper Teaching Landscape Spatial Design with Grading Studies: An Experiment Based on High Fidelity DTM Pang Li 1 1 Landscape Architecture Department, School of Architecture, Southeast University/China
More informationModeling and Simulation on Temperature Control System of Farm Products Baking Equipment. Liu Jun, Jia Zhenwei, Guo Rongxing
Applied Mechanics and Materials Online: 2013-07-31 ISSN: 1662-7482, Vols. 341-342, pp 801-804 doi:10.4028/www.scientific.net/amm.341-342.801 2013 Trans Tech Publications, Switzerland Modeling and Simulation
More informationFire Situations and Prevention Measures of residential building
Fire Situations and Prevention Measures of residential building Baixia Zhou Public Security Fire Forces College, Kunming 650208, China. Abstract. The proportion of residential building is the largest in
More informationEXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION
Eighth International IBPSA Conference Eindhoven, Netherlands August 11-14, 2003 EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION Liu Jing 1, Yoshihiro Aizawa 2, Hiroshi Yoshino 3 1 School of Municipal
More informationVideo Smoke Detection using Deep Domain Adaptation Enhanced with Synthetic Smoke Images
Video Smoke Detection using Deep Domain Adaptation Enhanced with Synthetic Smoke Images Gao Xu, Qixing Zhang, Gaohua Lin, Jinjun Wang, Yongming Zhang State Key Laboratory of Fire Science, University of
More informationHeat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling
Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,
More informationU.S. Fire Department Profile 2015
U.S. Fire Department Profile 2015 April 2017 Hylton J.G. Haynes Gary P. Stein April 2017 National Fire Protection Association Abstract NFPA estimates there were approximately 1,160,450 firefighters in
More informationShortcut Model for Predicting Refrigeration Cycle Performance
17 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 5, 15 Guest Editors: Petar Sabev Varbanov, Jiří Jaromír Klemeš, Sharifah Rafidah Wan Alwi, Jun Yow Yong, Xia Liu Copyright 15, AIDIC Servizi S.r.l.,
More informationEfficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station
Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station Normuminov J.A. Assistant, Dean of Heat Power Engineering, Tashkent State Technical University,
More informationNominee Statement for Mr. Wang Aiguo
Nominee Statement for Mr. Wang Aiguo Since 2010, Mr. Wang Aiguo has been working as the Director General of the Department of Irrigation, Drainage and Rural Water Supply under the Ministry of Water Resources
More informationDesign of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *
2016 International Conference on Artificial Intelligence: Techniques and Applications (AITA 2016) ISBN: 978-1-60595-389-2 Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time
More informationThermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning
Available online at www.sciencedirect.com Systems Engineering Procedia () 6 International Conference on Risk and Engineering Management (REM) Thermodynamic analysis of air cycle refrigeration system for
More informationSimple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings
Fire Science and Technorogy Vol.24 No.4(2005) 165-178 165 Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings Jun-ichi Yamaguchi 1, Takeyoshi Tanaka 2 1 Technical Research
More informationSmoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates
Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates Zhou Y., Fei Y.*, Hu S. Q. Nanjing Tech University, College of Fire Safety Science and Engineering &
More informationContemporary Urban Design in Chinese Cities
Contemporary Urban Design in Chinese Cities Tingwei Zhang, PhD Professor, Department of Urban Planning and Policy Director, Asia and China Research Program, GCI University of Illinois at Chicago Background:
More informationExperimental Research On Gas Injection High Temperature Heat Pump With An Economizer
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Research On Gas Injection High Temperature Heat Pump With
More informationSimulation of Evacuation Process in a Supermarket with Cellular Automata
Available online at www.sciencedirect.com Procedia Engineering 52 (2013 ) 687 692 Simulation of Evacuation Process in a Supermarket with Cellular Automata ZHONG Wei a, TU Rui a, YANG Jian-peng b, LIANG
More informationScholars Research Library. The Role of Plant Clinic in Protecting Vertical Urban Green Spaces in Tehran
Available online at www.scholarsresearchlibrary.com Annals of Biological Research, 2011, 2 (3) :255-261 (http://scholarsresearchlibrary.com/archive.html) ISSN 0976-1233 CODEN (USA): ABRNBW The Role of
More informationA Comparative Study on the Utilization Configuration and Characters of Urban Comprehensive Park in China and Korea
International Conference on Management Science and Innovative Education (MSIE 5) A Comparative Study on the Utilization Configuration and Characters of Urban Comprehensive Park in China and Korea Xiaoyan
More informationGPPS-2017-Put 4 digit paper number here
Proceedings of Shanghai 2017 Global Power and Propulsion Forum 30 th October 1 st November, 2017 http://www.gpps.global GPPS-2017-Put 4 digit paper number here THE RESEARCH ABOUT INFLUENCE OF WET STEAM
More informationDevelopment of Bionic Air Cooler Used in High Temperature Coal Mine
Advances in Natural Science Vol. 3, No. 2, 2010, pp. 206-212 www.cscanada.net ISSN 1715-7862 [PRINT] ISSN 1715-7870 [ONLINE] www.cscanada.org *The 3rd International Conference of Bionic Engineering* Development
More information1st City Issues Tongji International Symposium City & Real Estate Risk Management 2010
1st City Issues Tongji International Symposium City & Real Estate Risk Management 2010 (CI-TIS) Shanghai, China 16 17 October 2010 Editors: Nan-kai Xia Fang He ISBN: 978-1-61782-859-1 Printed from e-media
More informationResearch on Decision Tree Application in Data of Fire Alarm Receipt and Disposal
Research Journal of Applied Sciences, Engineering and Technology 5(22): 5217-5222, 2013 ISSN: 2040-7459; e-issn: 2040-7467 Maxwell Scientific Organization, 2013 Submitted: October 09, 2012 Accepted: December
More informationExperimental Research on Monomial Cooling Measure of Greenhouse in Summer
Smart Grid and Renewable Energy, 2013, 4, 48-52 http://dx.doi.org/10./sgre.2013.41007 Published Online February 2013 (http://www.scirp.org/journal/sgre) Experimental Research on Monomial Cooling Measure
More informationProcedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship
Available online at www.sciencedirect.com ScienceDirect Procedia - Social and Behavioral Sciences 195 ( 2015 ) 1846 1850 World Conference on Technology, Innovation and Entrepreneurship Fire Detection Systems
More informationPerformance of the Variable Refrigerant Volume Air-Conditioning System. with Heat Recovery
Performance of the Variable Refrigerant Volume Air-Conditioning System with Heat Recovery Shi Wenxing, Postdoctor, Department of Thermal Engineering, Tsinghua University, Beijing, China, Wenxingshi@263.net.cn
More informationApplication of Fuzzy Control in Central Air-conditioning Terminal Units Energy-saving
www.ijcsi.org 123 Application of Fuzzy Control in Central Air-conditioning Terminal Units Energy-saving Yanqiu Zhao 1, Yingli Lv 1, Yong Gu 1, Shucheng Liu 2 1 Department of Electrical Engineer, Hebei
More informationEnergy efficient washingmachines
Appliances Guide Get super efficient appliances Energy efficient washingmachines Country China Authors Hu Bo/ Zhao Feiyan Published: 2014/1 bigee.net Wuppertal Institute for Climate, Environment and Energy.
More informationExperimental Study and Analysis of Condenser Performance under Dual Backpressure Operation Mode
International Conference on Civil, Transportation and Environment (ICCTE 2016) Experimental Study and Analysis of Condenser Performance under Dual Backpressure Operation Mode Guangyao Liu1,a, Xiewei Cheng2,b,
More informationExperimental Investigation of Purification Function of Air Conditioner
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 10 Experimental Investigation of Purification Function of Air Conditioner Qi
More informationFeasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System
Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Kwanghee Seo 1) and Taewan Kim 2)* 1) KEPCO Engineering & Construction Company. INC., 269 Hyeoksin-ro,
More informationSPEECH PRIVACY DISTANCE IN 3 OPEN-PLAN OFFICE LAYOUTS: COMPUTER MODELLING AND SIMULATION APPROACH
SPEECH PRIVACY DISTANCE IN 3 OPEN-PLAN OFFICE LAYOUTS: COMPUTER MODELLING AND SIMULATION APPROACH Joko Sarwono, Annisa E. Larasati, F.X. Nugroho Soelami, and Indra Sihar Department of Engineering Physics,
More informationAnalysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate
Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate KEYWORDS: Steel-plate forming, Induction heating, Triangle heating, Transverse shrinkage,
More informationSuitability analysis of heritage corridor based on GIS and Remote Sensing Case study of region along the Zhangzhou ancient post road
289-Paper Suitability analysis of heritage corridor based on GIS and Remote Sensing Case study of region along the Zhangzhou ancient post road 1 Huagui Guo and *Qingming Zhan Abstract It s insufficient
More informationReceived: 26 th Feb-2014 Revised: 29 th March-2014 Accepted: 30 th March-2014 Research article
Received: 26 th Feb-2014 Revised: 29 th March-2014 Accepted: 30 th March-2014 Research article THE ROLE OF PLANT CLINICS IN INCREASING KNOWLEDGE, ATTITUDE AND SKILLS OF EXPERTS IN COMBATING PLANT PESTS
More informationDevelopment of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation
Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation Wei-kun Ding*, Ju-fang Fan*, Wen-quan Tao*, Wenson Zheng, Frank Gao, Kerry Song *School of Energy & Power Engineering,
More informationSTUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER
, Volume 6, Number 4, p.168-172, 2005 STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER Zhaohui Qi School of Energy Science and Engineering, Centralsouth University, Changsha,
More informationCase Studies of Master Planning for Sustainable Urban Underground Space Utilization
Case Studies of Master Planning for Sustainable Urban Underground Space Utilization Zhu Wenjun 1, Wang Hui 1, Li Chuanbin 2, Wei Lijun 3 1 Department of Civil Engineering, Tsinghua University, Beijing,
More informationOpen Access Suburban Composite Landscape Corridor Design Based on Flow Concept in Dinghai District of Zhoushan
Send Orders for Reprints to reprints@benthamscience.ae 298 The Open Construction and Building Technology Journal, 2015, 9, 298-302 Open Access Suburban Composite Landscape Corridor Design Based on Flow
More informationThe Influence of the Courtyard Geometry on the Passive Lighting Energy Savings Jie TAN 1,* Xin GUO 2 and Ming-ping ZHANG 1
2016 2nd International Conference on Sustainable Energy and Environmental Engineering (SEEE 2016) ISBN: 978-1-60595-408-0 The Influence of the Courtyard Geometry on the Passive Lighting Energy Savings
More informationStudy on the Influence of Urban River Topology on Landscape Design
2017 3rd International Conference on Social Science, Management and Economics (SSME 2017) ISBN: 978-1-60595-462-2 Study on the Influence of Urban River Topology on Landscape Design Tao Zhang 1 Abstract
More informationFactors affecting quality of social interaction park in Jakarta
IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS Factors affecting quality of social interaction park in Jakarta To cite this article: N I Mangunsong 2018 IOP Conf. Ser.: Earth
More informationsolution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem
A Simplified model for estimating the regeneration effectiveness of a counter flow regenerator for a liquid desiccant system M.H. Kim 1, H.J. Cho 1, and J.W. Jeong 1* 1 Division of Architectural Engineering,
More informationFire Detection Using Image Processing
Fire Detection Using Image Processing Ku. R.A.Agrawal ME Student Department of CSE Babasaheb Naik college of Engineering Pusad, India rachanaagrawal90@gmail.com Prof. S.T.Khandare Associate professor Department
More informationAn Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning
ISBN 978-93-84468-94-1 International Conference on Education, Business and Management (ICEBM-2017) Bali (Indonesia) Jan. 8-9, 2017 An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery
More informationExperiment Study in Optical Fiber Temperature Monitoring
Experiment Study in Optical Fiber Temperature Monitoring HE Jun, DONG Hui-juan, YANG Kan, ZHANG Guang-yu (School of Mechatronics Engineering, Harbin Institute of Technology, Harbin150001, China) Abstract:
More informationImpacts of an Energy Star Promotion
Impacts of an Energy Star Promotion Jack Habart and Joe Kelly, Habart and Associates Consulting Inc. Iris Sulyma and Ken Tiedemann, BC Hydro ABSTRACT BC Hydro s Power Smart group has been encouraging the
More informationRole of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview
International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com
More informationThe Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures
Advanced Materials Research Online: 2013-06-27 ISSN: 1662-8985, Vols. 712-715, pp 1614-1618 doi:10.4028/www.scientific.net/amr.712-715.1614 2013 Trans Tech Publications, Switzerland The Energy Consumption
More informationDynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink
Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink 1 Asoka R.G, 2 Aishwarya N, 3 Rajasekar S and 4 Meyyappan N 1234 Department of Chemical Engineering Sri Venkateswara College of Engineering,
More informationCONVECTIVE HEAT AND MASS TRANSFER DURING VACUUM DRYING PROCESS
60 (6): 2015 929-938 CONVECTIVE HEAT AND MASS TRANSFER DURING VACUUM DRYING PROCESS Zhengbin He, Zijian Zhao, Yu Zhang, Huan Lv, Songlin Yi Beijing Forestry University, Beijing Key Laboratory of Wood Science
More informationEnergy Performance of a Desiccant and Evaporative Cooling-assisted Airconditioning System under Various Climatic Conditions in China
Energy Performance of a Desiccant and Evaporative Cooling-assisted Airconditioning System under Various Climatic Conditions in China S. Y. Li 1, H. S. Lim 1, J. H. Shin 1, M. S. Jo 1, and J. W. Jeong 1
More informationAn Eco- economics Analysis on Construction and Development of New Urban Areas
Proceedings of the 7th International Conference on Innovation & Management 1967 An Eco- economics Analysis on Construction and Development of New Urban Areas Liang Hongzhi School of Architecture & Civil
More informationDesign Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System
Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, J.Y.Park 1, E.J.Lee 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang University,
More informationTESTS OF ADSIL COATING
TESTS OF ADSIL COATING Test B - Long Term Test FSEC-CR-1259-01 July 11, 2001 Prepared for: Bob Suggs Florida Power & Light Company 9250 W. Flagler Street Miami, Florida 33174 Principal Investigator Dr.
More informationINDOOR AIR QUALITY IN ENGLISH HOMES - NITROGEN DIOXIDE
INDOOR AIR QUALITY IN ENGLISH HOMES - NITROGEN DIOXIDE SKD Coward, GJ Raw, JW Llewellyn and DI Ross BRE, Watford WD25 9XX, UK ABSTRACT BRE has conducted a national survey of air pollutants in 876 homes
More informationA Study on the 2-D Temperature Distribution of the Strip due to Induction Heater
, pp.1-5 http://dx.doi.org/10.14257/astl.2015.90.01 A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater Jong-Hyun Lee 1, Jin-Taek Kim 1, Sung-Hyuk Lim 2, Do-Gyun Jung 2, Hyeong-Jin
More informationThe Study about the Solid Waste Automatic Sorting System at the Source Take Beijing for Example Xiaoci Wang1
2nd International Conference on Economy, Management and Education Technology (ICEMET 2016) The Study about the Solid Waste Automatic Sorting System at the Source Take Beijing for Example Xiaoci Wang1 1
More informationPerformance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Performance Investigation of Refrigerant Vapor- Injection Technique for
More informationThermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23
Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23 A. D. Parekh, P. R. Tailor Abstract The Montreal protocol and Kyoto protocol underlined the need of substitution
More informationHEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1
HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil
More informationPRELIMINARY ANALYSIS OF THE NUMBER OF OCCUPANTS, FIRE GROWTH, DETECTION TIMES AND PRE-MOVEMENT TIMES FOR PROBABILISTIC RISK ASSESSMENT
PRELIMINARY ANALYSIS OF THE NUMBER OF OCCUPANTS, FIRE GROWTH, DETECTION TIMES AND PRE-MOVEMENT TIMES FOR PROBABILISTIC RISK ASSESSMENT DAVID CHARTERS DEAN MCGRAIL Arup Fire, 78 East Street, Leeds, LS9
More informationSimulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio
International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol.4, No.4, pp 1633-1641, Oct-Dec 2012 Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading
More informationStudy of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator
Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator Mr. Subodh S. Deshpande Department of Mechanical Engineering M.G.M.s College of Engineering
More informationComputer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies
MATEC Web of Conferences 13, 27 (214) DOI: 1.151/ matecconf/ 21413 27 C Owned by the authors, published by EDP Sciences, 214 Computer Simulation Investigation on the Effect of Channelled and Unchannelled
More informationAdditional Information for the Proposed Methodology Energy Saving by Introduction of High Efficiency Once-through Boiler
Additional Information for the Proposed Methodology Energy Saving by Introduction of High Efficiency Once-through Boiler 1. Market Condition of Boilers in Indonesia 1.1 Number of boiler units sold in Indonesia
More informationFeasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System
Feasibility of a Liquid Desiccant Application in an Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, S.K.Han 1, S.Y. Cho 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang
More information2012 International Symposium on Safety Science and Technology Investigation on compressed air foams fire-extinguishing model for oil pan fire
Available online at.sciencedirect.com Procedia Engineering 45 (212 ) 663 668 212 International Symposium on Safety Science and Technology Investigation on compressed air foams fire-extinguishing model
More informationNew fire control system design for fire fighting and rescue equipment Jianguo LUO1, a, Zehao BU2, b
6th International Conference on Information Engineering for Mechanics and Materials (ICIMM 2016) New fire control system design for fire fighting and rescue equipment Jianguo LUO1, a, Zehao BU2, b 1 Department
More informationAnalysis of Pullout Resistance of Soil-Nailing in Lateritic Soil
Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil B,L.A. Isaka 1, B.C. Madushanka 1 and N.H. Priyankara 1 1 Department of Civil and Environmental Engineering Faculty of Engineering University
More informationNUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A
NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A [1] Ranendra Roy, [2] Madhu Sruthi Emani, [3] Bijan Kumar Mandal [1], [2],[3] Department of Mechanical
More information