PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Size: px
Start display at page:

Download "PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres"

Transcription

1 PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres

2 LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light fittings XFFL Range - XFF Range - Fluorescent Tubular glass light fitting for All components mounted on sliding gear tray for easy installation and maintenance Available in glass for chemical environment and corrosive atmospheres Including accessories (cable gland, plug & fixing brackets) Supplied with offshore grade paint II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C 12W, 19W, 25W, 31W, 56W, 71W Vac 50/60Hz XFP Range - Fluorescent with automatic switch off - module with diffuser II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C Vac 50/60Hz Vdc XEL BAES Range - Self-contained Battery 3h - XFF EM ( Vac/Vdc 50/60Hz) II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C Vac 50/60Hz 110Vdc Battery 3h - XFP EM ( Vac/Vdc 50/60Hz) II 2 G, Ex d IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C Db & 230Vac 50/60Hz Battery 3h - XFP EM ( Vac/Vdc 50/60Hz) Weatherproof polycarbonate tubular light fitting for industrial application FFL Range - FF Range - Fluorescent Ingress protection IP66 ideal for wash down areas All components mounted on a removable gear tray which gives easy access for installation & maintenance Tubular shape to avoid waste accumulation Including accessories (cable gland & fixing brackets) Possibility to retro-fit gear tray into existing fixtures mounted with T8 lamps. IP66, -20 C to +55 C 12W, 19W, 25W, 31W, 56W, 71W Vac 50-60Hz IEC 62262: IK09 - module with diffuser IP66, -20 C to +55 C Vac 50-60Hz Battery 3h - self test - FF EMB IEC 62262: IK09

3 PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Light fittings for all zones and industrial applications Floodlights, beacons, warnings & wellglass XLF Range - XSF / XQF / XEF Range Floodlight fitting for & Industrial applications Integrated junction box Flat or pole mounting Including cable gland Supplied with offshore grade paint II 2 G, Ex de IIB T6 Gb for -20 C to +40 C or Ex de IIB T5 Gb for -20 C to +55 C or Ex de IIB T4 Gb for -20 C to +60 C II 2 D, Ex tb IIIC T85 C Db IP66 for -20 C to +40 C or Ex tb IIIC T100 C Db IP66 for -20 C to +55 C or Ex tb IIIC T135 C Db IP66 for -20 C to +60 C 105W Vac (+/- 10%) 50/60Hz Operating life > 50,000h (according to ambient temperature) IEC 62262: IK09 More than 7800 lumens output with narrow & wide beam II 2 G, Ex de IIB T3 or T4 or T5 Gb for -20 C to +40 C, Ex de IIB T4 or T3 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T100 C or T135 C or T200 C Db IP66 for -20 C to +40 C, Ex tb IIIC T200 C or T135 C Db & HP Sodium: 150W, 250W, 400W Metal Halide: 250W, 400W Halogen: 2x70W 230Vac 50Hz Other Voltages: 220Vac 60Hz / 120Vac 60Hz Flat or pole mounting SF / QF / EF Range Industrial applications Wellglass, beacon & warning light for industrial application & zones 2 & 22 - Wellglass Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge lamp according to models - Beacon & warning light Static, halogen or flashing xenon versions available Supplied with lamp installed Including accessories (cable gland & plug) EVH, EVX Range - Wellglass II 2 GD, Ex d IIC T5 to T3 Gb, Ex tb IIIC T95 C to T164 C & HP Sodium: 70W, 150W, 250W, 400W Metal Halide: 150W, 250W, 400W Halogen: 70W, 140W, 250W 230Vac 50Hz Four 3/4 NPT entries - fitted with 2 plugs IP66, -20 C to +55 C HP Sodium: 150W, 250W, 400W Metal Halide: 250W, 400W Halogen: 2x70W 230Vac 50Hz Other Voltages: 220Vac 60Hz / 120Vac 60Hz XFB / XFL / FB / FL Range - Beacon & warning light Flat or pole mounting II 3 G, Ex na IIC T5 Gc for -20 C to + 60 C II 3 D, Ex tc IIIC T100 C Dc & IP6X for -20 C to + 60 C Halogen 28W, 6W Xenon 30 Joules Halogen 230Vac/Vdc 50/60Hz Vac 50/60Hz Xenon Flash 230Vac 50/60Hz Cable gland, plug & lamp

4 LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Linear light fittings EVS Range - Fluorescent EVNL Range - Linear light fitting for all zones & Industrial applications Double central locking for ingress protection Automatic switch off upon opening for safe maintenance All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable gland & fixing brackets) II 2 G, Ex de IIC T4 Gb for -40 C to +60 C or Ex de IIC T5 Gb for -40 C to +35 C II 2 D, Ex tb IIIC T85 C Db & IP66 for -40 C to +60 C EVN Range - Fluorescent 108 to 254V ac or dc Battery 3h - EVS EM Battery 3h with automatic test and blackstart capabilities - EVS EMA II 3 G, Ex na IIC T5 for -40 C to +25 C, T4 for -40 C to +60 C Gc II 3 D, Ex tc IIIC T65 C for -40 C to +35 C or T85 C for -40 C to +60 C Dc Zones 2 & 22 EVDL Range W, 19W, 25W, 31W, 56W, 71W Vac 50-60Hz - module with diffuser II 3 G, Ex na IIC T4 Gc for -40 C to +40 C, Ex na IIC T3 Gc for -40 C to +60 C II 3 D, Ex tc IIIC T65 C Dc IP66 for -40 C to +40 C, Ex tc IIIC T85 C Dc & IP66 for -40 C to +60 C Zones 2 & Vac or dc Battery 3h - self test - EVN EMB II 2 D, Ex tb IIIC T85 C Db for -40 C to +60 C, Ex tb IIIC T65 C Db for -40 C to +35 C Zones 21 & 22 12W, 19W, 25W, 31W, 56W, 71W Vac 50-60Hz - module with diffuser EVD Range - Fluorescent EVT Range - Fluorescent Industrial applications EVTL Range - Industrial applications II 2 D, Ex tb IIIC T85 C Db for -40 C to +60 C, Ex tb IIIC T65 C Db for -40 C to +35 C Zones 2, & Vac/Vdc 50-60Hz Battery 3h - self test - EVD EMB Vac or dc 50-60Hz Battery 3h - self test - EVT EMB 12.6W, 19W, 25W, 31W, 56W, 71W Vac 50-60Hz - module with diffuser

5 PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Light fittings for all zones and industrial applications Recessed light fittings & es and control stations ESB Range - Fluorescent Recessed lighting fitting for zones 1 & 2 Steel housing and body powder paint coated 6mm clear toughened glass panel Including accessories (cable gland) II 2 G, Ex de IIC T4 Gb for -40 C to +60 C Zones 1 & Vac or dc 50/60Hz Battery 3h - ESB EM GUV Range - Aluminum XBL Range - Polyester XBI Range - Stainless steel 316L II 2 G IEC 60529: IP56 Zones 1 & 2 3 or 4x entries 3/4 NPT 1 NPT Stainless steel screw ISO entries and threads Stainless steel captive screws Control station ISO entries and threads Stainless steel captive screws Control station EFDC, SRC, XMC Range - Aluminum XB Range - Aluminum XB100 Range - Polyester II 2 G IEC 60529: IP56 Zones 1 & 2 2x entries 3/4 NPT fitted with one plug Stainless steel screw Control station ISO entries and threads Stainless steel captive screws Control station 4x M20 entries - fitted with 4 cable glands & 1 plug, for armored & non armored cable

6 LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Custom-built control panels One need, one control panel Custom-built control panel 02 EJ Range control panel About DTS DTS is part of the ABB group and provides a complete range of explosion proof lighting, emergency lighting, enclosures, junction boxes and control panels. Our DTS range covers all zones of potential explosion gas & dust atmospheres and is compliant with most stringent national, European and international regulations including IECEx and ATEX standards, making it possible to be used in a wide variety of industries across most of the world. Our value commitment DTS is committed to helping you meet the challenges of corrosion prevention with electrical solutions, services and systems that deliver value. DTS helps to make your life easier by the practicality of its designs by providing effective advice and by being responsive to your need. Approvals / Characteristics DTS control panels are designed, manufactured and tested according to the ATEX protection type Ex d. (Ex d type of protection: Flameproof enclosure) 02 They can be composed of a wide variety of standard components which are switches, contactors and relays for instance. These components can be mounted into explosion proof enclosures built to keep internal explosions from igniting the surrounding atmosphere.

7 PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Control panel & es for zones 1, 2, 21 & ABB DTS 4 step process for creating a custom-built panel 01 Design 02 Stock 02 Drill 04 Assemble 01 EJB Cast aluminum custom-built control panels for Robust construction Wide variety of sizes Large choice of electrical components Customised to user s specification Custom-built control panels DTS Ex d control panels are constructed and tested according to ATEX/IECEx protection type Ex d. Available with a wide variety of components such as switches, contactors and relays, which can be mounted into flameproof enclosures constructed to keep internal explosions from igniting the surrounding atmosphere. Ex d control panels are usually custom-built in cooperation with the customer to suit their specific application requirements. EJ Range - Cast Aluminum Robust construction Wide variety of sizes Options: Boxes provided with load-break switch: Visible breaking Switch off and on under load and provide safety cut off XBL Range - Polyester XBI Range - Stainless steel 316L XB Range - Aluminum 2x entries 3/4 NPT fitted with one plug Stainless steel screw ISO entries and threads Stainless steel captive screws 4x M20 entries - fitted with 4 cable glands & 1 plug, for armored & non armored cable

8 new.abb.com/low-voltage/hazardous YouTube Channel Copyright 2017 ABB. All rights reserved. Specifications subject to change without notice. 17TC001025B

DTS Light fittings for explosive atmospheres

DTS Light fittings for explosive atmospheres DTS Light fittings for explosive atmospheres For all zones and industrial applications LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx 60W Flameproof LED Emergency Linear Fixture - 100-250V AC - (2) 30W LED Lamps - ATEX/IECEx Part #: ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V Page: 1 The Larson Electronics ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55 www.stahl.de > Pre-wi ready-to-use multi-signalling unit > Corrosion resistant > Suitable for offshore / onshore harsh environments > Incorporates the FX15 GRP beacon YA90 for visual audible notification

More information

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial

More information

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated 40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated Part #: HALD-24-1X40CPR-LED-V2 Page: 1 The Larson Electronics HALD-24-1X40CPR-LED-V2 Explosion Proof LED Fixture provides

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

ARRAN LED LED FLOODLIGHT. Standard Specification. Features ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

Ex LED light fittings

Ex LED light fittings About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment

More information

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light LED NEW FB-SERIES LED NEW-SF FIXTURE LED Explosion-proof Platform Light LED Tri-proof Light LED Explosion-proof Highbay Light LED NEW-CF FIXTURE LED Highbay Light LED Explosion-proof Light LED Explosion-proof

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

XLFE-4/1. Borosilicate glass globe

XLFE-4/1. Borosilicate glass globe XLFE-4/1 Borosilicate glass globe - Zone 1, 2, 21, 22 - Obstruction warnings - LOW INTENSITY LED technology - Lamp lifespan more than 10 years - Complies with ICAO, FAA Painted aluminium body Ex e terminal

More information

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS 100+ YEARS Federal Signal is recognized as one of the industry s leading suppliers of safety

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

Illumination unit For sight glass level indicator Model LGI

Illumination unit For sight glass level indicator Model LGI Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high

More information

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments. HDL106 LED LUMINAIRES For Harsh & Hazardous Environments www.chalmit.com Quality, Reliability and Low Maintenance Our LED Product Range Chalmit has over a century s worth of experience in providing cutting

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL 25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 5720 IR Detection of carbon dioxide Dräger Polytron 5720 IR Detection of carbon dioxide The Dräger Polytron 5720 IR is a cost effective explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

INTRINSICALLY SAFE LIGHTING RANGE

INTRINSICALLY SAFE LIGHTING RANGE Trusted worldwide since 1989 INTRINSICALLY SAFE LIGHTING RANGE SAFE PORTABLE RECHARGEABLE AC MAINS Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Industrial Signalling

Industrial Signalling Industrial Signalling Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place. Product Range

More information

Telephony & Communication

Telephony & Communication Telephony & Communication Avertisseurs sonore et visuel Détecteur Communication Eclairage Equipement d installation Contrôle commande for Industry and Hazardous Product at a Glance Telephone I Mobile phone

More information

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada

More information

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC 208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC Part #: EPL-EMGX-LP-2X48-LED Page: 1 The Larson Electronics EPL-EMGX-LP-2X48-LED Low Profile Explosion Proof

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts. Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw

More information

DB4 Range - SPEAKERS - Up to 25 Watts

DB4 Range - SPEAKERS - Up to 25 Watts DB Range - SPEAKERS - Up to 5 Watts Hazardous Location, Weatherproof Features UL listed for USA and Canada Class I, Div, Groups A, B, C & D. Class I, Zone, AExd IIC T. CSFM approved. ATEX approved. NEMA

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT FEDERAL SIGNAL CORPORATION Vitalite Rotating Warning Light Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT Available in 12VDC and 24VDC Five dome colors 121 - Magnetic mount with cigarette lighter cord

More information

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights CCA-03EX - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22 Directional LED spotlights Body and lid in coated aluminium LED for proper operation monitoring 127 ED.2018

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExS110D-SIL Flameproof Sounders For use in Flammable Gas Atmospheres BExS110D-SIL 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

Explosion-proof Immersion Heater Type D-8660

Explosion-proof Immersion Heater Type D-8660 Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to

More information

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres Includes NEW LinkEx LE Wolf Safety Lamp Company The widest range of portable ATEX lighting approved for use in explosive atmospheres Wolf Safety have Ex lighting products for all purposes, the correct

More information

Industrial & Hazardous Area Electrical Equipment

Industrial & Hazardous Area Electrical Equipment Industrial & azardous Area Electrical Equipment 2017 Abtech has been supplying electrical connection products to hazardous and industrial markets since the 1970 s. Our range includes hazardous area lighting,

More information

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres Includes NEW ATEX Fluorescent Leadlamp Range Wolf Safety Lamp Company The widest range of portable ATEX lighting approved for use in explosive atmospheres Wolf Safety have Ex lighting products for all

More information

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE 26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE Part #: EPL-LP-12-LED Page: 1 The EPL-LP-12-LED from Larson Electronics is a Low Profile Explosion Proof

More information

Helyum. Feam Product Brochure LOCATION CERTIFICATES REFERENCES. Milan / ITALY ATEX, IECEX, EX GOST, INMETRO, NEC500-5

Helyum. Feam Product Brochure LOCATION CERTIFICATES REFERENCES. Milan / ITALY ATEX, IECEX, EX GOST, INMETRO, NEC500-5 2016 Feam Product Brochure LOCATION Milan / ITALY- 1961 CERTIFICATES ATEX, IECEX, EX GOST, INMETRO, NEC500-5 REFERENCES Eni, Saipem, Tecnimont, GE Oil Gas, Technip, ABB Group, Foster Wheeler, Saudi Aramco,

More information

Beacons, Lights & Strobes

Beacons, Lights & Strobes Beacons, Lights & Strobes MEDC's range of beacons, including flashing, steady-state indicators and rotating units, provide solutions for potentially explosive and harsh environmental conditions. These

More information

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations AEU1 Explosion-Proof Electric Air Heater For Hazardous Locations 0518 II 2G, Ex d IIB T4 Gb IP55 (ATEX) Ex d IIB T4 Gb IP55 (IECEx) 1ExdIIBT4 X IP55 (EAC Ex) (Suitable for ATEX/IECEx/EAC Ex Zone 1 & 2)

More information

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations Global Series Model G-STR Strobe Beacon For Use in Hazardous Locations Ex d Surface Mount Ex de Surface Mount Installation and Maintenance Instructions 25500185 Rev. B4 1217 Printed in U.S.A. Limited Warranty

More information

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications Micro and Mini Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Micro and Mini es use high-tech light sources to give impressive performance with a compact size, designed for easy

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition

More information

High bay LED lighting fixture

High bay LED lighting fixture Supporting bracket EWL - Zone 1, 2, 21, 22 - Replacing traditional discharge lamps of up to 750W - Savings in energy, maintenance and installation costs - Instant, brilliant illumination - Suitable for

More information

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date: Page 1 of 9 TECHNICL MNUL EXPLOSION PROOF STTUS LIGHT / LMP TEX Marking: Code: II 2GD EPL Gb, Db Ex d IIC T4/T5/T6 IP66 Ex tb IIIC TXXX C Marking details: Please note that every care has been taken to

More information

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22 JAMIN 100 Compact impervious luminaire for ATEX zones Zones 2, 21, 22 JAMIN 100 ATEX LIGHTING THEY TRUST US: ACETEX CHIMIE, ADISSEO, ADNATCO (Abu Dhabi National Tanker Company), Airbus, BRITISH PETROLEUM,

More information

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

Hubbell Harsh & Hazardous. Our Brands. Corporate Information www.chalmit.com Hubbell Harsh & Hazardous Extreme environments demand superior performance, which is why you will find Hubbell products and systems installed in some of the most arduous and safety critical

More information

EVLPF Series Compact Fluorescent

EVLPF Series Compact Fluorescent EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence

More information

HAZARDOUS AREA SOLUTIONS

HAZARDOUS AREA SOLUTIONS HAZARDOUS AREA SOLUTIONS Lighting ATEX Zones 0,1, 2, 20, 21 and 22 v. 2.0/16 2 Delvalle, wide experience in manufacturing solutions for hazardous area WE PUT AT YOUR DISPOSAL We offer over 40 years providing

More information

Hazardous Area Signalling

Hazardous Area Signalling Hazardous Area Signalling Model# Combination Alarm Horn Sounders and Beacons/Lights Approval Enclosure Zone / Division IS-mC1 L.E.D. 37 BExCS110-05 Xenon 5 BExCS110 -L2 L.E.D. 5 D1xC1X05R Xenon 17 D1xC1X10R

More information

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white . TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8

More information

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax: distributed by Sole Agent in reat China Universky (Jiangsu) Technologies, Inc. #7 Belt Lake (Lian hu) Industrial Park, anyang, Jiangsu, China 212300 Phone: +86 511 86537777 Fax: +86 511 8628263 E-mail:

More information

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications SafeSite LED Area Light - ATEX / IECEx for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 Features & Benefits 5 year warranty L70

More information

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC 25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame - 120-277V AC Part #: EXHL-TRN-LE1-1227 Page: 1 Made in Texas The EXHL-TRN-LE1-1227 from Larson Electronics is an Explosion

More information

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable 120W Hazardous Location LED Fixture - 12-24V DC - Modbus TCP/IP - Network Controlled - Dimmable Part #: HAL-ANC-60-120W-ITG-LED-DIMM-1224 Page: 1 The Larson Electronics HAL-ANC-60-120W-ITG-LED-DIMM-1224

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection Dräger Flame 2500 (IR3) Flame Detection With its triple IR sensor The Dräger Flame 2500 detects hydrocarbonbased fires even over greater distances. Moreover, it offers a high reliability against false

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

Hubbell Harsh & Hazardous. Our Brands. Corporate Information www.chalmit.com Hubbell Harsh & Hazardous Extreme environments demand superior performance, which is why you will find Hubbell products and systems installed in some of the most arduous and safety critical

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

HAZARDOUS AREAS. Ex APPROVED EXPLOSION-PROOF PRODUCTS. technor.com

HAZARDOUS AREAS. Ex APPROVED EXPLOSION-PROOF PRODUCTS. technor.com HAZARDOUS AREAS Ex APPROVED EXPLOSION-PROOF PRODUCTS technor.com 2 CONTENT INTRODUCTION + Ex REGULATIONS LIGHTING Fluorescent // LED // Wellglass // Tank // Spot Lights // Floodlights // Hand Lamps CONTROL

More information

PRODUCT NEWS FLASHING BEACONS FOR RUGGED CONDITIONS IN HAZARDOUS AREAS NEW FX15 SERIES OF FLASHING SIGNAL LIGHTS FOR USE IN EX ZONE 1/2 AND 21/22

PRODUCT NEWS FLASHING BEACONS FOR RUGGED CONDITIONS IN HAZARDOUS AREAS NEW FX15 SERIES OF FLASHING SIGNAL LIGHTS FOR USE IN EX ZONE 1/2 AND 21/22 FLASHING BEACONS FOR RUGGED CONDITIONS IN HAZARDOUS AREAS NEW FX15 SERIES OF FLASHING SIGNAL LIGHTS FOR USE IN EX ZONE 1/2 AND 21/22 Robust flashing beacons from R. STAHL s new FX15 series are suitable

More information

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Drive systems for the chemical, oil and gas industry. Electric drives and systems Drive systems for the chemical, oil and gas industry Electric drives and systems 2 VEM drive systems for the chemical, oil and gas industry VEM drive systems for the chemical, oil and gas industry 3 VEM

More information

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer - 140 - C1D1 - C2D2 - ISO 14644/FS-209E Part #: HALD-24-1X150LED-V2-140DB Page: 1 Made in the USA The HALD-24-1X150LED-V2-140DB from Larson Electronics

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection Dräger Flame 2350 (UV&IR) Flame Detection The Dräger Flame 2350 combines UV and IR sensors for the detection of hydrocarbon-based fires. This combination of sensors offers you more security and fewer false

More information

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection Dräger Flame 2700 (Multi-IR) Flame Detection With its multichannel IR sensor the Dräger Flame 2700 detects hydrocarbon- and hydrogen-based fires. Thereby it offers a high reliability against false alarms.

More information

Champ-Pak Wall Pack Luminares

Champ-Pak Wall Pack Luminares Champ-Pak Wall Pack Luminares Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F, G Cl. III & Simultaneous

More information

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2100 (UV) Flame Detection Dräger Flame 2100 (UV) Flame Detection A short response time and high reliability against false alarms are the features of the Dräger Flame 2100. Its UV sensor is quick to detect hydrocarbon- or hydrogen-based

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,

More information

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and vapors Dräger Polytron 8100 EC Detection of toxic gases and vapors The Polytron 8100 EC is Dräger s top of the line explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

BC9700 series High Power LED Explosion Proof Light

BC9700 series High Power LED Explosion Proof Light BC9700 series High Power LED Explosion Proof Light Characteristics IECEx ATEX LM79 LM8 IP 66 Ta 0/55 Ta -0 Application Zone,zone ;zone,zone Suitable for Low installation height in Moist corrosive environment,such

More information

ELECTRICAL EX EQUIPMENT

ELECTRICAL EX EQUIPMENT ELECTRICAL EX EQUIPMENT in hazardous areas Enclosures Reliable Customized Solutions Leader in Explosion Proof Protections CB Control Panel Configuration - Gas group IIB / Dust group IIIC Ex d enclosures

More information

SOLUZIONI PER ATMOSFERA ESPLOSIVA

SOLUZIONI PER ATMOSFERA ESPLOSIVA catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first

More information

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and oxygen Dräger Polytron 8100 EC Detection of toxic gases and oxygen The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications ZONE 1 ZONE 2 INDUSTRIAL SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications ATEX and IEC Ex approved Zone 1 Zone 2 variant also available Ultra long life LED High lumen output LED Easy installation,

More information