A REVOLUTIONARY APPROACH TO FIRE SAFETY

Size: px
Start display at page:

Download "A REVOLUTIONARY APPROACH TO FIRE SAFETY"

Transcription

1 Fire Curtains Fire Rated Shutters Smoke Curtains DC FIRE Motors A REVOLUTIONARY APPROACH TO FIRE SAFETY Unique Patented Technology for the 21st Century

2 WELCOME TO NECO FIRE GARD Founded over 10 years ago, NECO Fire Gard is a leading provider of fire safety solutions for small and large businesses within the retail, hospitality, transport, aviation and construction industries. We specialise in the manufacture, supply and installation of a wide range of Fire Curtains, Smoke Curtains and Fire Rated Roller Shutters. We are committed to investing heavily in research and development to ensure we continue to deliver innovative, industry-leading products and services which exceed the scrupulous standards demanded by the Fire Safety Industry in the UK and Internationally. Customer service is of paramount importance to us. We pride ourselves on providing a bespoke personalised service, working in partnership with customers to deliver cost-effective fire and smoke safety solutions from specification, to installation and maintenance. To find out more about how we can help you please contact our Sales Team via info@necogroup.eu or call on

3 DC Gravity & Controlled Descent and Non-Gravity Fail-Safe Tubular Motors FEATURES TECHNICAL INFORMATION Lifting capacity up to 200kg Gravity Fail-Safe feature available on models: DC55G, DC55G-25, DC80G, DC80G-19 & DC95G Suitable for use with Fire/Smoke Curtains, Fire Shutters and High Usage Doors Tested and approved by Exova, Warringtonfire DC55 DC55G DC55G-25 DC80 DC80G DC80G-19 DC95 DC95G Voltage 24v 24v 24V 24v 24v 24v 24v 24v Current 3.2a 3.2a 3.2a 8.5a 8.5a 8.5a 10.8a 10.8a Running Time 30min 30min 30min 30min 30min 30min 30min 30min Torque 30nm 15nm 25nm 80nm 80nm 30nm 120nm 100nm RPM 18rpm 40rpm 25rpm 12rpm 12rpm 19rpm 10rpm 8rpm Drop Weight n/a 10kg 20kg n/a 20kg 10kg n/a 25kg Lifting Capacity 50kg 15kg 15kg 100kg 80kg 40kg 200kg 100kg DC110 DC120 DC140 DC140Q DC160 Voltage 24v 24v 24v 24v 24v Current 10.8a 19.8a 18.5a 19.8a 14.6a Running Time 30min 30min 30min 30min 30min Torque 200nm 380nm 420nm 600nm 600nm RPM 10rpm 8rpm 6.5rpm 140rpm 4.2rpm Lifting Capacity 300kg 400kg 600kg 50kg 800kg

4 NECO DC Fire Control Panel HIGHLIGHTS Up to 96 hours of battery back-up Volt-free fire alarm connection Additional battery back-up Includes the NECO DC Tubular Motor & the NECO Group Controller Only compatible with the NECO DC Tubular Motor DESCRIPTION The Neco DC Fire Control Panel is the heart of our range of Neco Fire Curtains, Smoke Curtains and Fire Shutters. It offers many features which deliver full control with all site situations. FEATURES Electronic Limits A fire/smoke curtain can be commissioned without gaining access to the motor. All limits are set from the control panel. If you need to return to site to commission your fire/smoke curtain, only one engineer is required. Battery Back-Up: If the power supply fails, the inbuilt battery back-up system maintains operation of the fire/smoke curtain until the power is restored (up to 96 hours). Audio Visual A full audio siren and flashing beacon are supplied. These can be (dis)connected depending on the site requirements. Split Drop Delay Once the alarm is activated, the fire/smoke curtain will descend to the middle split drop limit and remain in this position for up to 16 minutes. It acts as a smoke curtain and prevents the spread of smoke, allowing people to escape before it descends to the floor. Delay Before Descent Once the fire alarm is activated, the curtain will remain in the up position ensuring the safe evacuation of the building. After a set period of time (up to 16 minutes), it will automatically close.

5 FEATURES Continued... Deadman and Auto Operation The control panel can be placed in either automatic operation up or automatic operation down, or automatic operation up and deadman down. Auto Return Reset Function Once the fire alarm is activated, the fire/smoke curtain will descend to the floor. It will remain in this position whilst the alarm is activated. Once the alarm is reset, the curtain will automatically return to the open position. This feature is important where numerous fire/ smoke curtains are installed. All the curtains will return to the open position without having to raise each individual curtain. Emergency Retract If the fire/smoke curtain is activated a trapped person can press the emergency switch and raise the curtain to escape to the nearest fire exit. Volt Free Fire Alarm Connection The control panel is designed to receive a volt free fire alarm signal. This can open or close. Double Knock Fire Activation The control panel can operate a double knock fire alarm activation. This means that when the fire alarm is activated the curtain will descend to the split drop delay limit and act as a smoke curtain only. The fire curtain will only reach the floor once a second signal is received either from a second fire signal or a stand alone relay based smoke or heat detector. Building Management System The control panel can connect the fire curtains to connect to a building management system. This allows a person in a control room or designated area to monitor all the fire/smoke curtains. For example, if the fire alarm is activated the relevant person can check to see if all curtains have descended without having to walk around the building. Obstacle Detection A photo cell can be attached to the fire/smoke curtain with a flashing beacon and sounder and connect to the control panel. This means that if an object is placed under the curtain the alarm will sound until the object is removed.

6 NECO DC Group Controller FEATURES Simultaneously operates up to 20 motors Only compatible with NECO DC Tubular Motors Suitable for all commercial and retail sites/ premises DESCRIPTION The NECO DC Group Controller can be connected to the NECO fire curtain system. Fire Curtain Systems +6 meters wide The group controller can operate multiple rollers connected to one fire curtain system once the fire alarm is activated. Multiple Fire Curtains Where multiple fire curtains are fitted across a site, the group control panel operates them at the same time. Fire Alarm If only one fire alarm connection is available, all the fire curtains can be connected through the group control panel.

7 NECO Fire Gard Fire Curtain FEATURES Offers up to 4 hours fire and smoke protection Made with NECO 240+ Fabric or NECO 60min Fully complies to BS & EN standards Available with gravity and controlled descent INSTALLATION All NECO Fire Gard fire curtains are made to order. Installation and training is available for all our fire safety products. Please contact us for more information or to receive a quote. COMPLIANCE All NECO Fire Gard fire curtains comply to the following standards: BS 476 Part 22 EN :2006 EN : 2005 & A1: 2006 BS BSEN 949: 2000 BSEN : 1999 BSEN : 2000 BSEN : BSEN : 2000 BS EN : 2007 & A1: 2009 BSEN : 2004

8 NECO ELECTRICAL UK COMPANY LIMITED For information, to get a quote please contact a member of our Sales Team via info@necogroup.eu or on Unit 8, Curran Industrial Estate Curran Road, Cardiff, CF10 5DF Registered in the United Kingdom Reg No VAT Number:

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c CI/SfB (68.5) February 2012 Intelligent security and fire protection SecureFire S e c SecureFire Flame Curtain Easily concealed, quickly enabled SecureFire Flame Curtain Intelligent automatic fire curtain

More information

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire

More information

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd Smoke and Fire Curtains Performance Door sets for security and Fire resistant applications Introduction The Fire & Smoke curtains are the latest in fire protection systems to be added to the Doors (UK)

More information

PRODUCT SPECIFICATION FireMaster Plus

PRODUCT SPECIFICATION FireMaster Plus PRODUCT SPECIFICATION FireMaster Plus 1 GENERAL 1.1 Scope Coopers FireMaster Plus active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated, delivered, installed and commissioned

More information

Firetex steel fire shutters

Firetex steel fire shutters Firetex steel fire shutters Firetex; safe, versatile and efficient Firetex shutters are a range of proven fire and smoke control products meeting the requirements of building regulations and life safety

More information

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS   LEADING THE WAY IN FIRE PROTECTION SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION evacu8 THE SMOKE BARRIER SmokeStop evacu8 is a unique patented bi-roller system which has interweaving,

More information

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS WWW.COOPERSFIRE.COM VII FIRE ACTIVE FIRE CURTAIN BARRIER FOR YOUR HOME AND COMMERCIAL PROPERTY. From architects to homeowners to commercial

More information

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: FORTNUM & MASON LONDON UK Active Fire Curtain Barrier

More information

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 PREMIER EX8 EXTINGUISHING PANEL USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 & EN54 PARTS 2 & 4 USER MANUAL Approved Document No: GLT.MAN-132 INDEX Extinguishing

More information

WARNING FIRE DOOR CLOSING

WARNING FIRE DOOR CLOSING PRODUCT INSTRUCTIS Stock Code: 088 FCP - Lite Floats Road, Wythenshawe Manchester, M 9WB Tel: + (0) 9 Fax: + (0) 9 Doc No PI - 88 Iss:.0 WARNING FIRE DOOR CLOSING STOP Contents ) Blank ) Features and

More information

Technical Manual (European Standards)

Technical Manual (European Standards) Technical Manual (European Standards) Version 1.0 (0517) - System Overview - Installation - Maintenance & Troubleshooting - Manufacturing Information THE LEADING EDGE IN Smoke & Fire Curtains Office Tel:

More information

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3 Automatic Smoke & Fire Curtain Surveying Manual Table of Contents Before the Survey 2 Carrying out the Survey 2-3 Site Survey Further Information 3-6 Site Survey Report Sheet 7-8 Smoke & Fire Curtains

More information

PRODUCT SPECIFICATION FireMaster Plus Concertina

PRODUCT SPECIFICATION FireMaster Plus Concertina PRODUCT SPECIFICATION FireMaster Plus Concertina 1 GENERAL 1.1 Scope Coopers FireMaster Plus Concertina active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated, delivered,

More information

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 PRODUCT DATA SHEET AUTOMATIC FIRE CURTAIN FM 1 AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 FM-1 fire curtains are used where, if there is a fire, it is necessary to create a temporary barrier within an opening

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

FIRE & SMOKE CURTAINS

FIRE & SMOKE CURTAINS FIRE & SMOKE CURTAINS APPLICATIONS FOR FIRE AND SMOKE CURTAINS AND THE PRODUCT RANGE AVAILABLE WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION COMPANY PROFILE COOPERS FIRE Coopers Fire operates

More information

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES   LEADING THE WAY IN FIRE PROTECTION FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM.AU LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU Active Fire Curtain Barrier Assemblies comprise technologically

More information

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income. W W W. C O O P E R S F I R E. C O M FireMaster CONCERTINA THE INVISIBLE ACTIVE FIRE CURTAIN BARRIER ASSEMBLY Cl/Sfb (31.5) Fire Doors The Fire Curtain Barrier WITHOUT CORNER POSTS Inspiring design, maximising

More information

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

SAC 100 Automatic Smoke Curtain System. - Specifier Information - SAC 100 Automatic Smoke Curtain System - Specifier Information - CONTENTS 1. Introduction Page 3 2. Construction and Method of Operation Page 5 3. Performance 3.1. Resistance to Fire/Heat Page 6 3.2. Deflection

More information

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: FORTNUM & MASON LONDON UK Active Fire Curtain Barrier

More information

FIREMASTER CONCERTINA TM

FIREMASTER CONCERTINA TM FIREMASTER CONCERTINA TM CONCERTINA TM THE INVISIBLE ACTIVE FIRE CURTAIN BARRIER ASSEMBLY WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: OIL SEARCH

More information

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION MEANS OF ESCAPE PROTECTION CASE STUDY: SSE HYDRO GLASGOW UK

More information

FIRE & SMOKE CURTAINS

FIRE & SMOKE CURTAINS FIRE & SMOKE CURTAINS APPLICATIONS FOR FIRE AND SMOKE CURTAINS AND THE PRODUCT RANGE AVAILABLE WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION TESTING AND STANDARDS COMPANY PROFILE COOPERS FIRE

More information

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped) In accordance with: BS EN 8524-1 BS EN 1634-1 BS 5234-2 BS EN 14600 BS EN 13501-2 BS EN ISO 1716 BS EN 13501-1+A1 BS EN ISO 14184-1 BS EN 12101 10 BS ISO 21927 9 Period of Fire Resistance: 180 minutes

More information

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15. In accordance with: BS EN 12101-1+A1 BS EN 1363-1 BS EN 1634-3 BS EN 13501-4 BS EN ISO 1716 BS EN 13823 BS EN 13501-1 BS 476-6 BS 476-7 Period of Fire Resistance: 60 minutes (1 hour) integrity Classification:

More information

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex 1 GENERAL 1.1 Scope Coopers FireMaster NVS Horizontal Simplex active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated,

More information

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains THE LEADING EDGE IN > Automatic Smoke Curtains > Automatic Fire Curtains > Static Smoke Curtains > Accordion & Horizontal Curtains > Service & Maintenance L&F SMOKE & FIRE Smoke & Fire Curtains A Lowe

More information

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham. Exova Warringtonfire Key Industrial ark Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : willenhall@exova.com W: www.exova.com EN 1155:1997 TESTS OF

More information

MINERVA MX. 800 Series Ancillary Equipment

MINERVA MX. 800 Series Ancillary Equipment An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree

More information

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual Conventional Fire System BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual Contents Contents 1. INTRODUCTION... 3 1.1 Purpose...3 1.2 Definitions....3 Premises Management...

More information

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL 3500 CONVENTIONAL FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web:

More information

Fire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau

Fire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau Fire PROtec Manual for automatic Fire Curtains Edition B /2007 All information are subject to technical changes, errors excepted Contents 1. System Description Page 3-4 1.1 General 3 1.2 Fire curtain sizes

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

A Guide To BS Understanding the selection, spacing and siting of detectors

A Guide To BS Understanding the selection, spacing and siting of detectors World Class Leaders in Fire Detection Since 1918 A Guide To BS5839-12017 Understanding the selection, spacing and siting of detectors Welcome to A Guide to BS5839 Part 1 : 2017 from HOCHIKI EUROPE (UK)

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM PART 1 - GENERAL 1.01 SUMMARY SECTION 08 34 84 ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM A. Section Includes: Fire protective elevator smoke containment curtain system designed to provide a tight-fitting,

More information

SMOKE AND FIRE CURTAINS

SMOKE AND FIRE CURTAINS SMOKE AND FIRE CURTAINS ALWAYS PROTECTING PEOPLE Specialising in fire and smoke engineering solutions for the construction and industrial, Smoke and Fire curtains, GELEC is the world-wide supplier and

More information

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM) DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT PRODUCT CODE: 35023 UNICLASS: L4231 EPIC: D25 VERSION: Issue M Aug 2018 PRODUCT DESCRIPTION The Variospeed 6 ERU-CAM is used in conjunction with the Variospeed

More information

MINERVA MZX125 Digital Addressable Fire Detection System

MINERVA MZX125 Digital Addressable Fire Detection System DATASHEET MINERVA MZX125 Digital Addressable Fire Detection System The Minerva MZX125 is a highly featured digital addressable panel with a comprehensive but easy to operate user interface. The system

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual for Model 2100 Fire+Smoke systems from Smoke Guard, Inc. 287 N. Maple Grove - Boise, ID 83704 Phone: (800) 574-0330 Fax: (208) 639-7851 E-Mail: info@smokeguard.com Website:

More information

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions TS400 & TS410 Intruder Alarm Control Panels Operating Instructions Zone Location Home Set Chime 1 Armed / Omitted 2 Armed / Omitted 3 Armed / Omitted 4 Armed / Omitted 5 Armed / Omitted F. Exit Always

More information

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator. Section 5 Operation To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator. Figure 5-1 Built-in Touchpad (Seven-Segment Display) Figure 5-2 Model 5230 Remote

More information

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book Noby-448 User Operating Manual & Log Book Page 1 of 12 Fire Control Panel User Operating Manual & Log Book TABLE OF CONTENTS Page Introduction 1 Keypad Operation 2 LED Indications 3 What to do in the event

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 highline WINDOW CONTROLS INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM SVCS-1 * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 CERTIFICATE OF COMPLIANCE SVCS-1 We the undersigned

More information

Smoke and Fire Curtains

Smoke and Fire Curtains Smoke and Fire Curtains NFPA UL Datasheet firecurtaintech.com SMOKE AND FIRE CURTAINS Fire Curtain Technologies distributes a wide range of fire and smoke protective curtains to protect every type of building

More information

Data Sheet. Abacus intruder alarm systems

Data Sheet. Abacus intruder alarm systems Data Pack Issued March 2001 232-4336 Data Sheet bacus intruder alarm systems n intruder alarm system is a secondary form of protecting a property. here is little or no point in fitting a system if you

More information

enhance your view Manufactured Your local Liniar stockist: For more information and to find your nearest fabricator visit

enhance your view Manufactured Your local Liniar stockist: For more information and to find your nearest fabricator visit Your local Liniar stockist: enhance your view Manufactured in the UK For more information and to find your nearest fabricator visit www.liniarwindows.co.uk Liniar is a new name in the windows industry

More information

Sita200plus. 200detectors. Single loop analogue addressable System

Sita200plus. 200detectors. Single loop analogue addressable System Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D

More information

Fire Command Keypad. XR5 User s Guide

Fire Command Keypad. XR5 User s Guide Fire Command Keypad XR5 User s Guide Silencing an Alarm While the fire alarm horns, strobes, or sirens are sounding use one of the following methods to silence the alarm depending on which type of keypad

More information

intelligent solutions

intelligent solutions Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have

More information

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1 U S E R M A N U A L UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1 0359 18 UBS1RF Optical Smoke Alarm OverView This optical smoke alarm is a fire detection and alarm device which gives

More information

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures Fire Safety Management Plan & Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of Fire 4.0 Means for Fighting Fire 5. 0 Discovering

More information

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FIREBETA EXTINGUISHING CONTROL PANEL (ECP) F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd THE NANO SYSTEM The revolutionary analogue addressable control panel Nano, the revolutionary control panel from Gent Nano is the latest fire detection control panel from Gent by Honeywell. It s a single

More information

Reflective Optical Beam Smoke Detector User Guide

Reflective Optical Beam Smoke Detector User Guide Reflective Optical Beam Smoke Detector User Guide 1. Installation IMPORTANT NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the system initiating

More information

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System World Class Leaders in Fire Detection Since 1918 FIREscape+ RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System GLOBALLY PROVEN PRODUCT DESIGN The F REscape+ system is the first of its

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

User s Information Guide R2A

User s Information Guide R2A Pi HSC505 Home Security Controller User s Information Guide R2A Page 1 of 15 of its development program. 1This document and product are copyrighted and all rights are reserved. Introduction Convention

More information

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL 6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0)

More information

Gas interlock system S & 100 CS

Gas interlock system S & 100 CS Gas interlock system - 100 S & 100 CS Features: Available as a stand-alone panel or supplied complete with air pressure switches (100 S) or integral current sensors (100 CS) Comprehensive fan, fire & emergency

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Fire detection and alarm

Fire detection and alarm Fire detection and alarm Aesthetic Install all cabling and cable containment neatly and unobtrusively, meeting the highest electrical industry installation standards. Neatly lay and securely fix cables.

More information

Building Technologies

Building Technologies Building Technologies The safe, sure way to more efficient evacuation: the E100 voice alarm system from Siemens. The safe, sure way to an evacuation system that gets people moving: the E100 from Siemens.

More information

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming Master Code The 4 digit Master Code is used for arming and disarming the system, for programming additional access codes, and for changing other features. The Master Code will be supplied to you by your

More information

Reference information

Reference information Reference information This section provides information on system limitations, emergency planning and smoke and heat detector locations. It also provides a place to list your sensor and module locations

More information

Working in Partnership with our Customers.

Working in Partnership with our Customers. 02 03 Introduction Working in Partnership with our Customers. At McElwaine Security our commitment to our customer is simple; we will provide an unrivalled end to end electronic security service and solutions,

More information

Control Panel User Guide

Control Panel User Guide Fire Detection & Alarm System Control Panel (Suitable for TWINFLEX pro control panels from V1.00) Control Panel User Guide (TO BE RETAINED BY THE USER) 26-1028 Issue 2 Fike s policy is one of continual

More information

Control box FSTronic DES-FS

Control box FSTronic DES-FS Control box FSTronic DES-FS Designed for drives of rolling fire shutters and sectional fire gates CONTENT: TECHNICAL REPORT 1. POWER SUPPLY 2. CONFIGURATION 3. INSTALLATION AND SETTING 4. DESCRIPTION OF

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

ECONX FIT OFF INSTRUCTIONS

ECONX FIT OFF INSTRUCTIONS ECONX FIT OFF INSTRUCTIONS 0 1. Labelling 2. Fit Off Alarm Sensors 3. Fit Off Smoke Sensors 4. Fit of Siren and Sounder 5. Partitioning, Night Arm and Panic Buttons 6. Fit Off Temperature Sensors 7. Fit

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

Control Panel User Guide (TO BE RETAINED BY THE USER)

Control Panel User Guide (TO BE RETAINED BY THE USER) Fire Detection & Alarm System Control Panel V3 (Suitable for Quadnet control panels from V2.00) Control Panel User Guide (TO BE RETAINED BY THE USER) 26-0585 Issue 7 Fike s policy is one of continual improvement

More information

Brochure. Security Designed, Installed by Experts

Brochure. Security Designed, Installed by Experts Brochure Security Designed, Installed by Experts 02 03 Introduction Working in Partnership with our Customers. At b2b Secure IT our commitment to our customer is simple; we will provide an unrivalled end

More information

All by design. ASSA ABLOY Door Controls

All by design. ASSA ABLOY Door Controls All by design. ASSA ABLOY Door Controls Designed to work for you ASSA ABLOY door controls span three technologies that cover everything you could want from a door closer: from unique features that enhance

More information

KFP-CF Series Operation Manual

KFP-CF Series Operation Manual KFP-CF Series Operation Manual P/N 501-415103-2-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire

More information

Flame Shutter & Flame Curtain Price List

Flame Shutter & Flame Curtain Price List Issue date: October 2014 Flame Shutter & Flame Curtain Price List Product overview SeceuroFire Flame Shutter Flame Shutter is an electrically operated vertical fire shutter, consisting of a steel slatted

More information

Commercial. Tel:

Commercial.   Tel: Commercial Being able to use your outdoor space can solve many commercial problems. Car park covers, loading bays, smoking shelters, walkways and storage covers are just some of the canopy solutions we

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions PRODUCT GUIDE & INFORMATION Professional Fire & Carbon Monoxide Solutions 1 Nearly 50 years experience of designing, manufacturing and supplying home safety products, makes BRK an industry leader. We believe

More information

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES   LEADING THE WAY IN FIRE PROTECTION CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION CATALOGUE CONTENTS kestop TM D00/90 & D00/80 page Product Matrix page SmokeStop D600A page

More information

SECURIT 700L USER MANUAL

SECURIT 700L USER MANUAL SECURIT 700L USER MANUAL C & K Systems Ltd 6/12/95 Securit 700L User instructions This manual will give you all the information you need to operate and control the Securit 700L Control Panel. This manual

More information

Specified Systems List

Specified Systems List Specified Systems List Index: SS 1 Automatic systems for fire suppression SS 2 Automatic or manual emergency warning systems for fire or other dangers SS 3 Electromagnetic or automatic doors or windows

More information

Fire Risk Assessment Nelson Cottage Bed & Breakfast

Fire Risk Assessment Nelson Cottage Bed & Breakfast Fire Risk Assessment Nelson Cottage Bed & Breakfast 2 Updated 1 st July 2017 Step 1 Identify fire hazards Sources of Ignition. Sources of fuel. Step 2 Identify people especially at risk Members of staff.

More information

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR _ PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR FEATURES: COMPLETELY PORTABLE OR WALL INSTALLATION CAN BE SET TO ANY WIDTH; QUICK SET UP VIDEO REAL-TIME DISPLAY & CAPTURE OPTIONAL: WIRELESS REMOTE NOTIFICATION

More information

MINERVA MZX125. Digital Addressable Fire Detection System

MINERVA MZX125. Digital Addressable Fire Detection System A C C E S S C O N T R O L C C T V E A S R F I D F I R E P R O T E C T I O N I N T R U D E R A L A R M S DATA SHEET MINERVA MZX125 Digital Addressable Fire Detection System Features: Long term service and

More information

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS) FIREIRE CURTAINSURTAINS Approved for use for 30m wide x 10m drop in accordance with AS1530.4 and AS1905.2 KEY FEATURES Fire tested in accordance with AS1530.4 (Up to 2 hours) GENERAL Fibershield automatic

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL DOC: GLT.MAN-136 1 INDEX INTRODUCTION 3 CONNECTIONS 4 OPERATION 5 LINKING 6 TECHNICAL INFO 7 DOC: GLT.MAN-136 2 INTRODUCTION The Dynameco

More information

5 Sounds and Indications

5 Sounds and Indications 5 Sounds and Indications 5.1 Sounder Tones Mode: Tone: 5.2 Indications Exit Soft continuous tone Fault on exit Soft intermittent tone Entry Soft pulsing pips Walk test Soft pulsing pips Keypad entry Soft

More information

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009 Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3

More information

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE Fire Safety Technical Note ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE Access Security & Accessible Door Opening Systems - what you need to know: Access

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

Fire Precautions, Evacuation and Emergency Control Procedure Denmead Scouts HQ

Fire Precautions, Evacuation and Emergency Control Procedure Denmead Scouts HQ Fire Precautions, Evacuation and Emergency Control Procedure Denmead Scouts HQ Document Details Originator: Craig Thompson February 2012 CONTENTS 1 Introduction 3 2 Scope 3 3 Roles and Responsibilities

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

The EN54 Part 2 and 4 Fire System

The EN54 Part 2 and 4 Fire System Scope of work: To design, supply, install and commission a Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54 Part 2 and 4 Fire

More information

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions EN54-3:2001+A1:2002+A2:2006 EN54-7:2000+A1:2002+A2:2006 EN54-25:2008 0359 Electro Detectors Ltd. Electro

More information

Welcome to. Welcome to Security and Peace of Mind CASTLE CARE TECH CARE TECH CARE TECH CARE TECH

Welcome to. Welcome to Security and Peace of Mind CASTLE CARE TECH CARE TECH CARE TECH CARE TECH Welcome to Welcome to Security and Peace of Mind CARE TECH CARE TECH CARE TECH CASTLE CARE TECH Contents Introduction A1-3 Using Meridian with your PIN Code B1-7 Using Meridian with your Tag C1-8 When

More information