1 MT-RJ Optical Fiber System Field Testing

2 Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style) ports... 6 MT-RJ SYSTEM TESTING: Fixed transmit (SC or ST-style) and interchangeable receive ports... 9 CALCULATE SYSTEM LOSS CONCLUSION Copyright 2009 Tyco Electronics Corporation. All Rights Reserved.

3 INTRODUCTION This paper describes two field test procedures for the MT-RJ optical fiber system. ANSI/TIA-568-C.0, Generic Telecommunications Cabling for Customer Premises, currently recommends the one jumper reference test method. This procedure is described in TIA/EIA A, method B, Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant, and TIA/EIA-526-7, method A.1, Measurements of Optical Power Loss of Installed Single-mode Fiber Cable Plant. These documents use procedures that assume the test equipment has the same connector interface as the patch panel and outlet. This can be a problem when testing a fiber network that uses a different connector type other than the test equipment interface ports. While Dual-fiber designs such as the MT-RJ are a popular installation choice, a majority of the test equipment in use today have fixed transmit and receive ports with SC or ST- style connectors. In these cases, the one jumper reference measurement procedure must be slightly modified to test the MT-RJ system. The MT-RJ connector presents other unique testing challenges simply because it is a fixed duplex (2 fiber) connector. To properly test the MT-RJ system with the recommended one jumper reference method, test units with fixed transmit ports and an interchangeable receive port with a MT-RJ interface are required. In an effort to clarify these procedures, this paper will describe the necessary steps for MT-RJ system testing with equipment using: - Fixed transmit and receive ports other than MT-RJ (SC or ST- style) - Fixed transmit (SC or ST- style) and interchangeable receive ports that include MT-RJ 3 Copyright 2009 Tyco Electronics Corporation. All Rights Reserved

4 TEST JUMPERS To ensure accurate and repeatable test results, quality test jumpers must be used during testing. It is essential that proper test jumpers are maintained with proper cleaning techniques throughout testing. More often than not, high losses experienced during testing are a result of poor quality test jumpers. AMP NETCONNECT offers test kits comprised of quality jumpers in the proper configuration and fiber type for use with SC, ST- style, or MT-RJ interface test equipment. These kits are available to test either standard MT-RJ or MT-RJ SECURE systems. Additionally, individual jumpers are available to replace jumpers if they become damaged or worn after repeated use. LAUNCH CONDITIONS Another important factor in obtaining accurate and repeatable results is the launch condition on the source. ANSI/TIA-568-C.0 and ISO 11801, as well as AMP NETCONNECT, recognize the importance of a conditioned launch by recommending the use of mandrel wraps during the reference set up and the actual test. Multimode optical fiber may appear to have higher than expected attenuation due to the power loss in the high-order modes. To remove the high-order mode transient losses from the multimode optical fiber measurements, the reference jumper should be wrapped in five non-overlapping turns around a smooth mandrel during the reference calibration and for all loss measurements. The mandrel diameter depends on the fiber core size and also the specification being followed. Below is an illustration of the mandrel wrap using the mandrels supplied in the test kits: 50/125um IEC 50/125um ANSI/TIA /125um IEC and ANSI/TIA Copyright 2009 Tyco Electronics Corporation. All Rights Reserved.

5 MT-RJ TEST KITS Equipment Transmit Port Fiber Type Part Number ST-Style SC 50/125um /125um Single-mode /125um /125um Single-mode Test Kits for the MT-RJ SECURE connector system are available through your local AMP NETCONNECT Sales Engineer. Replacement Components for MT-RJ Test Kits Connector End 1 Unpinned MT-RJ Pinned MT-RJ Connector End 2 Unpinned MT-RJ SC ST-Style SC ST-Style Fiber Type Part Number 50/125um /125um Single-mode /125um /125um Single-mode /125um /125um Single-mode /125um /125um Single-mode /125um /125um Single-mode MT-RJ to MT-RJ Coupler Mandrels, set of two, 50/125um type Mandrels, set of two, 62.5/125um type Each Test Kit includes: 1 MT-RJ Coupler 2 MT-RJ (no pins) to SC Simplex or ST-style Cable Assemblies 1 MT-RJ (with pins) to SC Simplex or ST-style Cable Assembly 1 MT-RJ to MT-RJ Cable Assembly 2 Mandrels (not included with Singlemode Kit) 1 Carrying case For XG fiber testing, use standard 50/125um Multimode products 5 Copyright 2009 Tyco Electronics Corporation. All Rights Reserved

6 MT-RJ SYSTEM TESTING Fixed transmit and receive equipment ports other than MT-RJ (SC or ST- style) Step 1 Verify the test leads are in good condition and are continuous for all fiber paths. If there is any doubt about the cable assembly, or if test results are erratic or unusually high, replace the assembly before conducting any testing. Replacing reference test leads after a reference value has been obtained requires a new reference measurement before further testing. Install the mandrel on the transmit (Tx) leg (both A or both B sides) of the cable assemblies by applying five non-overlapping wraps around the mandrel (Figure 1). Maintain this mandrel wrap during the reference and the test. The cable assembly can be held in place by installing a cable tie through the center hole in the mandrel and around the cable. Ensure the cable tie is not tightened to the point of compressing the jumper cable jacket. Step 2 Connect the pinned MT-RJ to SC or ST- style jumper and the unpinned MT-RJ to SC or ST- style jumper to the test units. Make sure the SC or ST- style connector polarity is correct (transmit to receive or A (Tx) to B (Rx) connection) (Figure 1). 6 Copyright 2009 Tyco Electronics Corporation. All Rights Reserved.

7 Tx Rx Tx Rx Figure 1 Step 3 Connect the two jumpers with the MT-RJ coupler (Figure 1). Record two power values, P1 and P2, one for each fiber path. These values are the Reference values for subsequent testing. Note: record all power values in dbm (or store values in equipment as reference values). Make sure the jumper fiber type matches the system fiber type under test. 7 Copyright 2009 Tyco Electronics Corporation. All Rights Reserved

8 Step 4 Disconnect the unpinned MT-RJ from the coupler, and insert this plug into the jack of one end of the Cable plant under test (Figure 2). Connect a standard (without pins) MT-RJ to MT-RJ jumper (MM) between the pinned MT-RJ test lead and the jack of the other Cable plant end. Record two power values, P1 and P2, one for each fiber path. Note: record all power values in dbm (most equipment will store these values and automatically calculate system link loss). Go to the Calculate System Loss section of this document to calculate the acceptable system loss. Tx Rx Tx Rx Figure 2 8 Copyright 2009 Tyco Electronics Corporation. All Rights Reserved.

9 MT-RJ SYSTEM TESTING Fixed transmit (SC or ST-style) and interchangeable receive port (MT-RJ, SC, or ST- style) Step 1 Verify the test leads are in good condition and are continuous for all fiber paths. If there is any doubt about the cable assembly, or if test results are erratic or unusually high, replace the cable assembly before conducting any testing. Replacing reference test leads after a reference value has been obtained requires a new reference measurement before further testing. Two unpinned MT-RJ to SC or ST- style assemblies are used as reference cables in this setup. Install the mandrel on the transmit (Tx) leg (both A or both B sides) of the cable assemblies by applying five non-overlapping wraps around the mandrel (Figure 3). Maintain this mandrel wrap during the reference and the test. The cable assembly can be held in place by installing a cable tie through the center hole in the mandrel and around the cable. Ensure the cable tie is not tightened to the point of compressing the jumper cable jacket. Step 2 Connect the MT-RJ to SC or ST- style jumpers to the test units (Figure 3). Make sure the mandrel leg is connected to the transmitter (Tx). Install a MT-RJ removable receptacle adapter to the receive (Rx) side of both test units. Plug the MT-RJ connector into the receive (Rx) side of the other test unit as shown in Figure 3. 9 Copyright 2009 Tyco Electronics Corporation. All Rights Reserved

10 Tx Rx Tx Rx Figure 3 Step 3 Record two power values, P1 and P2, one for each fiber path. These values are the Reference values for subsequent testing. Note: record all power values in dbm (or store values in equipment as reference values). Make sure the jumper fiber type matches the system fiber type under test. Step 4 Disconnect the MT-RJ connectors from the test units (Figure 4). Replace the MT-RJ receptacle caps with SC or ST- style adapter caps. Connect the SC or ST- style connectors that were not used in the reference measurement to the Receive (Rx) side of the test units. Connect the MT-RJ plugs to the Cable plant. Record two power values, P1 and P2, one for each fiber path. Note: record all power values in dbm (most equipment will store and automatically calculate system link loss). Go to the Calculate System Loss section of this document to calculate the acceptable system loss. 10 Copyright 2009 Tyco Electronics Corporation. All Rights Reserved.

11 Tx Rx Tx Rx Figure 4 11 Copyright 2009 Tyco Electronics Corporation. All Rights Reserved

12 CALCULATE SYSTEM LOSS Calculate system loss for each fiber by subtracting the system power values from the system reference values. Calculate the maximum allowable system loss by summing the maximum cable attenuation, connector attenuation, and splice loss for the link under test. LOSS system = LOSS cable + LOSS connector + LOSS splice Where: LOSS cable = Attenuation Coefficient [db/km] x Cable Length [km] Maximum Attenuation Coefficient for Cable (ANSI/TIA-568 and ISO except where noted) nm for multimode (50/125um, XG 50/125um, and 62.5/125um) nm for multimode (50/125um, XG 50/125um, and 62.5/125um) nm for single-mode outside plant cable for ANSI/TIA nm for single-mode outside plant cable for ANSI/TIA nm for single-mode outside plant cable for ISO nm for single-mode outside plant cable for ISO nm for single-mode inside plant cable nm for single-mode inside plant cable LOSS connector = Number of Connector Pairs x Connector Loss [db] Maximum Connector Loss (each): 0.75 db LOSS splice = Number of Splices x Splice Loss [db] Maximum Splice Loss (each): 0.3 db To be eligible for a 25-year warranty, the calculated system loss must be less than or equal to the maximum allowable system loss published in the current AMP NETCONNECT System Warranty. CONCLUSION These test procedures verify the attenuation and polarity of the installed MT-RJ system using common field test equipment. AMP NETCONNECT s MT-RJ test kits contain all the components and assemblies for both test configurations. 12 Copyright 2009 Tyco Electronics Corporation. All Rights Reserved.

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*

More information

Jan07 Rev B

Jan07 Rev B Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,

More information

Qualification Test Report LC Duplex Adapter For LC Cutouts

Qualification Test Report LC Duplex Adapter For LC Cutouts Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their

More information

4120 Fire Alarm Network Reference

4120 Fire Alarm Network Reference 4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards

More information

Apr06 Rev A

Apr06 Rev A Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece

More information

Fiber Optic Products Catalog

Fiber Optic Products Catalog Fiber Optic Products Catalog No epoxy, no polish, no crimp Two fibers in one ferrule MT-RJ Patch Panel Jack packages include: 6 MT-RJ Jacks 2 Actuator Tools 1 Fiber Guide 1 Icon Wheel Bend Limiting Boots

More information

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks Field Testing and Troubleshooting of PON LAN Networks per IEC 61280-4 Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning APC vs UPC PON basics Wavelengths Architecture

More information

Fibre (TIA) Field Test Specification

Fibre (TIA) Field Test Specification This document has been prepared to aid consultants or engineers in developing contractual specifications covering the testing of duplex fibre optic cabling installations. It is offered as a general guide.

More information

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing

More information

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Optical Return Loss Measurement by Gregory Lietaert, Product Manager White Paper Optical Return Loss Measurement by Gregory Lietaert, Product Manager Introduction With the increasing frequency of high-speed transmission systems and DWDM deployment, optical return loss (ORL)

More information

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. 3.4 TESTING OF FIBER OPTICS CABLING A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. B. General: In the event

More information

4-Channel Contact Closure Fiber Link Card System

4-Channel Contact Closure Fiber Link Card System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-020 2017A-0330 4-Channel Contact Closure Fiber Link Card System SYSTEM INSTALLATION INFORMATION Description The 4 Channel

More information

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015 Laser OWL Series Operations Guide Singlemode Light Sources OWL Optical Wavelength Laboratories Operations Guide Laser OWL and Laser OWL HP Singlemode Light Sources Date: October 1, 015 Version.5 Optical

More information

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes the following: 1. 50/125-micrometer, optical fiber cabling. 2. Cable connecting hardware, termination panels,

More information

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed* Simplex ES Network UL, ULC Listed* ES Net features ES Network (ES Net) is a high bandwidth (100 Mbps) IP based fire alarm network that supports up to 99 nodes and uses industry standard network technology

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING MITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 240 2017 SCTE Test Procedures for Testing CWDM Systems in Cable Telecommunications Access Networks NOTICE The Society

More information

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation. UL, ULC Approved* Fire Control Panels Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting Features Converts multiple fire alarm communications signals into a single fiber optic

More information

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features Fire Control Panels UL, ULC, CSFM Listed; FM Approved* Features Compatible with Simplex 4120 Network Converts multiple 4120 network communications signals into a single fiber optic link to: Multiplex audio

More information

Fiber Optic Distribution Cables (6-144 Fibers)

Fiber Optic Distribution Cables (6-144 Fibers) 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are

More information

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments MADE FOR THE TRADE! professional FIBER OPTIC XL fibertools Series instruments XL fibertools Series Instruments Designed for Fiber Optic Cable Testing. The XL fibertools are designed for the professional

More information

The Rise of Tier 2 Testing

The Rise of Tier 2 Testing The Rise of Tier 2 Testing Why enterprises today demand better visibility into their fiber infrastructure Unprecedented demand for more bandwidth, faster network speeds, lower latency, and improved data

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

FiberExpress Solutions

FiberExpress Solutions 7.2.1-A 7.2.1-B 7.2.1-C 7.2.1-D Simplex Patch Cord Duplex Patch Cord Hybrid Patch Cord Single-ended (pigtails) AX200057 Patch Cord Multimode SC Duplex DESCRIPTION FiberExpress Simplex and Duplex Patch

More information

Duct Cable GYTS-144B1.3

Duct Cable GYTS-144B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical

More information

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3 VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright

More information

Jul07 Rev C

Jul07 Rev C Product Specification 108-2167 11Jul07 Rev C MPO and MPO SECURE Multimode Fiber Optic Connector and Adapter 1. SCOPE 1.1. Content This specification, which is based on GR-1435-CORE, covers the performance,

More information

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment),

More information

Certified Fibre Optic Specialist - Testing

Certified Fibre Optic Specialist - Testing Certified Fibre Optic Specialist - Testing COURSE DESCRIPTION: This training program is designed to introduce the student to the process of fibre optic network testing. It is intended for those looking

More information

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments MADE FOR THE TRADE! FIBER OPTIC professional XL fibertools Series instruments XL fibertools Series Instruments Designed for Fiber Optic Cable Testing. The XL fibertools are designed for the professional

More information

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD 157 APPLICATION NOTE Mario Simard, Product Manager, Optical Business Unit The purpose of any fiber-optic network is to perform high-speed,

More information

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide

More information

Field Test Procedure for Optical Fibre Link Measurements

Field Test Procedure for Optical Fibre Link Measurements Application Notes Field Test Procedure for Optical Fibre Link Measurements Issued April 2014 Abstract After fiber optic cables are installed, spliced and terminated, they must be tested. For every fiber

More information

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE SECTION 27 16 19 COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary

More information

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team INTRODUCTION The OTDR is a very efficient tool for characterizing the elements on

More information

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014) FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014) OC1 FIBER LINK CHARACTERIZATION WITH OTDR *Note: On-the-spot evaluation may be carried out during or at the

More information

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS 1/10 FACULTY OF ENGINEERING LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS TRIMESTER 3, SESSION 2016/2017 Student Name: Student ID: Degree Major (please circle): EE

More information

Fibre Specification Standards

Fibre Specification Standards Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair

More information

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna Qualified Partner Programme QPP Field-termination of FO connectors Felice Guarna Introduction Fiber to the Home, Fiber to the Office and Fiber to the Desk are not just slogans and are state of the art

More information

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*

More information

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna enna (FTTA) Installation and Maintenance Testing

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

Fiber Optics and Liquid Level Sensors Line Guide

Fiber Optics and Liquid Level Sensors Line Guide Fiber Optics and Liquid Level Sensors Line Guide Excellence, through every fiber. Honeywell Sensing and Control (S&C) offers fiber optic sensors manufactured with SERCOS (Serial Real-time Communication

More information

Universal Connectivity Platform A Modular Approach to Infrastructure Design

Universal Connectivity Platform A Modular Approach to Infrastructure Design A Modular Approach to Infrastructure Design TE Connectivity s Universal Connectivity Platform (UCP) provides a fully modular approach to designing data centers and telecommunications rooms. This patch

More information

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC Philip C Longhurst Corporate Fibre Optic R & D Manager Outline CENELEC TC86BXA work programme IEC SC86B WG 6 and

More information

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Workshop format The Workshop is going to start with three short lecture style power

More information

Return loss measurement of fiber optic components

Return loss measurement of fiber optic components Return loss measurement of fiber optic components Solutions Brief 815-1 How the HP 8153A/HP 81534A measure return loss of fiber optic components? The significance of return loss The introduction of new

More information

MicrOTDR. Optical Fault Locator. User Manual

MicrOTDR. Optical Fault Locator. User Manual Optical Fault Locator Datacom Textron 11001 31 st Place West Everett, WA 98204 TEL: 425-355-0590 Toll Free: 800-468-5557 FAX: 425-290-1600 Internet: www.datacom.textron.com Warranty The MicrOTDR Optical

More information

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification Notice Copyright Every effort was made to ensure that the information in this document

More information

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005) RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

4009 Fiber Optic Link Option Installation Instructions

4009 Fiber Optic Link Option Installation Instructions 4009 Fiber Optic Link Option Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton

More information

LiteFENCE Lite with SV Lite Sensor

LiteFENCE Lite with SV Lite Sensor LiteFENCE Lite with SV Lite Sensor SECURITY DEVICE FOR PERIMETER PROTECTION INSTALLATION MANUAL LiteFENCE Lite analyser LFEN300F011L SV Lite sensor vibration sensor VBRS025S000L V. 003 1 LiteFENCE Lite

More information

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003 Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone

More information

Noyes OFL 250B Specs Provided by

Noyes OFL 250B Specs Provided by Noyes OFL 250B Specs Provided by www.aaatesters.com OFL 250 Handheld OTDR The Noyes OFL 250 from AFL Telecommunications is a single-mode OTDR with an integrated Optical Power Meter (OPM), Source (OLS),

More information

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:

More information

Connector Maintenance

Connector Maintenance Connector Maintenance Jean-François Lavoie, Product Manager, Industrial and Scientific Division Connectors are designed to require minimum maintenance in order to provide reliable operation for many years.

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F LD-64F INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG 6073-2011 Westermo Teleindustri AB 2001 REV. C Galvanic Isolation Transient Protection Balanced Transmission CE Approved Redundant linjedelare

More information

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET Optic Backbone Distribution Cables 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: TE

More information

Table of Contents 1Q08. Test & Inspection

Table of Contents 1Q08. Test & Inspection Table of Contents Optical Time Domain Reflectometers (OTDR) M700 Compact Single-mode OTDR....................... 3 M200 Handheld OTDR... 5 OFL-250 Handheld OTDR.... 7 OFL-200 Single-mode OTDR............................

More information

M-Series Compact OTDRs User s Guide

M-Series Compact OTDRs User s Guide M-Series Compact OTDRs User s Guide Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and workmanship for a period of one year from the date of shipment

More information

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS Wilcom Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS Model FR2 Operating Instructions 812-655-002 January, 2002 Copyright (c) 1999 Wilcom All Rights reserved Wilcom reserves the right

More information

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer Product Brochure & Data Sheet Headquarters: Phoenix, Arizona 20100, N 51st Ave, Suite

More information

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel December 5th, 2017 Acceptance Requirements Fibre Optic Systems Revised 12/2017 Alexander Kölbel +49 6190 8880-40 alexander.koelbel@datwyler.com Dätwyler Cables GmbH, Auf der Roos 4-12, 65795 Hattersheim,

More information

FiberSensor Fiber Optic Intrusion Detection System (IDS)

FiberSensor Fiber Optic Intrusion Detection System (IDS) FiberSensor Fiber Optic Intrusion Detection System (IDS) OPERATION & INSTALLATION MANUAL Dec 2009, Issue 3 1 Table of Contents 1.0 PRECAUTIONS... 2 2.0 GETTING STARTED... 3 System Components... 3 Operating

More information

OptiFiber Certifying OTDR. Certify it. Diagnose it. Document it.

OptiFiber Certifying OTDR. Certify it. Diagnose it. Document it. NETWORKSUPERVISION Certify it. Diagnose it. Document it. With the first integrated fiber troubleshooting and certification platform designed for network owners and installers. The use of fiber in premises

More information

M700-Series Multifunction OTDR

M700-Series Multifunction OTDR M700-Series Multifunction OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Test Modes Full Auto OTDR Normal (point-to-point) fiber cable construction testing and fault location

More information

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Ensuring Cabling Performance in the Customer-Owned Outside Plant Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof

More information

Set-Up Procedures. Before You Start

Set-Up Procedures. Before You Start Doc. 2272064, Rev. B Rel. 11/00 5000-ODA Amplifiers Ref. and Install. Manual Set-Up Procedures Before You Start In this section, you will find information about the following procedures: Checking the Optical

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 14763-3 First edition 2006-06 Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling Reference number ISO/IEC

More information

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical

More information

AS/NZS ISO/IEC :2012

AS/NZS ISO/IEC :2012 AS/NZS ISO/IEC 14763.3:2012 (ISO/IEC 14763-3:2011, MOD) Australian/New Zealand Standard Telecommunications installations Implementation and operation of customer premises cabling Part 3: Testing of optical

More information

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis Experience designing cable and network testers has enabled a breakthrough

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus LD-64 Profibus INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 6073-2031 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB 2001 REV. B Fiberoptiskt

More information

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT) TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions

More information

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation.  or (800) , (603) Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Industry leading TruEvent analysis Short dead zones provide precise testing of closely spaced events Front Panel and

More information

Fiber Optic Connector Cleaning and Inspection Kit Instructions

Fiber Optic Connector Cleaning and Inspection Kit Instructions Instruction Sheet 860376037 Rev E, March 2018 Fiber Optic Connector Cleaning and Inspection Kit Instructions General This instruction sheet describes the use of the CommScope Fiber Optic Connector Cleaning

More information

Fiber Optic Patch Cord and Pigtails

Fiber Optic Patch Cord and Pigtails Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable

More information

4 Channel Contact Closure SFP DIN Fiber Link System

4 Channel Contact Closure SFP DIN Fiber Link System USER GUIDE The leader in rugged fiber optic technology. U- 07A-0707 Channel Contact Closure DIN Fiber Link System Installation and Configuration Information Description The system provides transmission

More information

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500 OTDR MODULE SERIES LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500 NETWORK TESTING OPTICAL Platform Compatibility First-class benefits

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

Basic Professional Fiber Optic Installation

Basic Professional Fiber Optic Installation Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:

More information

Broadband System - H

Broadband System - H Broadband System - H Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz TV TRANSMITTER Headend

More information

IFS SFP Tranceivers User Manual

IFS SFP Tranceivers User Manual IFS SFP Tranceivers User Manual P/N 1069181 REV 02.00 ISS 22AUG11 Copyright Trademarks and patents Manufacturer 2011 UTC Fire & Security. All rights reserved. Interlogix, IFS SFP Tranceivers Brand and

More information

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES . SECTION 260523 - CONTROL-VOLTAGE ELECTRICAL POWER CABLES PART I - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km) FEATURES Dual Wavelength Bi-Directional Tx/Rx 1.25Gbps/1310nm Burst Mode Transmitter 1.25Gbps/1490nm CW Mode Receiver IEEE 802.3ah Compliant Single 3.3 Voltage Supply 2X10 SFF Package Outline Single Fiber

More information

OFS IV Optical Fibre System

OFS IV Optical Fibre System OFS IV Optical Fibre System FOR ALL FIBRE OPTIC USERS Fibre optic training has assumed great importance in today s world of widespread fibre optic usage whether in telecommunications or railways, industrial

More information

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet. Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) LS-1310/1550 Service Information Sheet Introduction This Service Information Sheet provides the following service information

More information

Telephone and Data Structured Wiring

Telephone and Data Structured Wiring Data Specification Category 6A General Telephone and Data Structured Wiring The Electrical Sub-Contractor shall employ a specialist sub-contractor to provide the following systems:- Manufacturer System

More information

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for

More information

Connections You Can Count On.

Connections You Can Count On. Connections You Can Count On. XPRESS ULTRA FIBER CONNECTOR PRODUCT GUIDE - CLEANING & INSPECTION - TESTING AND TROUBLE SHOOTING - XPRESS ULTRA FIBER CONNECTORS - INSTALLATION KITS Connections You Can Count

More information

Optical Multitester 500 450 OTDR EMEA & APac Edition Issue 1 Page 1 of 10 Description The 450 OTDR is a PC based state-ofthe-art OTDR designed for field applications. It is a dedicated OTDR which offers

More information

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0009 OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS EPN, LPN, SPN This standard details the requirements for the splicing,

More information

FTS510 Series. Handheld OTDR Test Set.

FTS510 Series. Handheld OTDR Test Set. www.opwill.com FTS510 Series FTS510 Series OTDR Tester is entirely new pad product released by OPWILL. It has rapid start technology and supports automatic and realtime test mode, which can guarantee engineers

More information

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh WHAT IS AN OTDR? A measurement technique which provides the loss characteristics of an optical link down its entire

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

FTS500 Series. Handheld OTDR Test Set.

FTS500 Series. Handheld OTDR Test Set. www.opwill.com OTDR Tester is entirely new pad product released by OPWILL. It has rapid start technology and supports automatic and realtime test mode, which can guarantee engineers to examine and detect

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication ISO/IEC 14763-3 CONSOLIDATED VERSION Edition 2.1 2018-08 colour inside Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling INTERNATIONAL

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

Universal Connectivity Platform

Universal Connectivity Platform Enabling Business Transformation through Agility Availability Efficiency UCP provides a fully modular approach to accommodate both copper and fiber into one common footprint, simplifying network architecture

More information

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution Undercarpet Cabling Products TE Connectivity Enterprise Networks Warranty Power Distribution Product Coverage* TE Connectivity warrants that all Undercarpet cabling system products within this catalog

More information