ONTARIO Electrical Safety Report. 10th Edition
|
|
- Branden Day
- 6 years ago
- Views:
Transcription
1 ONTARIO Electrical Safety Report 10th Edition 2010 OESR vmesf1.0 Electrical Safety Authority 2012
2 Electrical Engineers and Consultants perhaps not understanding all of the applicable regulations for Mines & Industrial Plants. Electricians and Electrical Contractors not up to date on regulations due to lack of upgrade training. Huge projects are putting significant demands on inspection oversight. Unapproved equipment being sold and incorporated into projects. Installations being performed that are not meeting minimum standards which affect reliability and safety OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
3 ESA Service Review of pre tender Engineered plans and specs Field review of installation Product Approvals Advisory Services Documentation Benefit to Mines Reduce or eliminate change orders related to errors in electrical design Ensure field installation does not sacrifice design integrity Ensure that equipment is legal for use and suitable for your operation Information portal on application of Codes & Regulations Understand amount of defects being installed by Contractor and project division OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
4 ESA Service Cold eye review of existing electrical system Plan reviews Advisory Services Code & Reg. Training CSA Z462 Product Approvals Benefit to Mines Identify deviations from minimum standards that will affect reliability and safety Ensure new proposed installations meet the Code and Regs. Ask the questions regarding elect. Maintenance and new work, eliminating rework Ensure qualified staff know how to install and maintain correctly. Improves system integrity Understanding Arc Flash and training on proper selection/application of PPE Approve equipment that is found to be unapproved OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
5 ESA sponsored initiative within the Ontario mining community Venue bringing key electrical safety stakeholders together to: Share important safety initiatives; Share interpretation of codes and standards to improve consistency; Identify current trends, weaknesses and gaps in mining electrical safety; Drive Industry Change for enhanced Electrical Safety; Meetings held bi annually, Spring & Fall OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
6 e plan Solution Benefits & Features... Compliance with CSA Z462, Workplace Electrical Safety Safe Work Packages Electrical Task Safety Summaries & Job Briefing Checklists Continuous support & updates from the ESA Records plant specific equipment limits of approach/ arc flash data, and employee & contractor data (e.g. trades, training & qualifications) Adapts well to different user needs Integrates custom features OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
7 ESA receives data from various resources to compile this report. Ontario Coroner s Office Ministry of Labour (MOL) Office of the Fire Marshal (OFM) Workers Safety and Insurance Board of Ontario (WSIB) Canadian Institute for Health Information (CIHI) Statistics Canada At the time of writing, the Coroner s reports for 2009 and 2010 are only partially completed due to pending investigations and confirmations. Where there are discrepancies in the number of fatalities reported by MOL and ESA, ESA uses the data provided by the Coroner. Electrocution an accidental death caused by the contact with electricity. Fatality an injury resulting in a death
8
9 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
10
11
12
13
14 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
15
16
17 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
18
19
20 An arc flash event injured three workers in a pulp and paper manufacturing facility when they were replacing a power box in the electrical room OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
21 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
22 The two electricians suffered first, second and third degree burns. A student who was watching them suffered first degree burns Owner Operator fined $125,000 after workers and student injured OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
23 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO
24
25
26
27 Ten storey building Fire in a ground floor, one bedroom apartment Seriously injured one person Cause: portable heater and its extension cord
28
29 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO ZER
30
31
32 ring the investigation, ESA found: The primary conductor was within 4 m of the house. Horizontal clearance met the 2009 OESC. 5 aluminum extension ladders were set up against the house. Workers were leap frogging them as they installed the soffit. Victim attempted to move one of the extension ladders and it touched the energized primary line. He was killed instantly. Burn marks can be seen at the point of contact on the power line and ladder. No disconnection request was made by the workers or homeowner.
33
34 Powerline contacts Electrical workers Product safety Aging infrastructure New wiring
35 GETTING TO
May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth
by Mark Hilbert and Laura L. Hildreth AND THE ELECTRICAL INSPECTOR May is National Electrical Safety Month, an annual effort to help reduce electricallyrelated fatalities, injuries, and property loss both
More informationT22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards
T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards v2-5058-co900h Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 1 Agenda 1. Background 2. Related Electrical
More informationArc Flash Protection Training - NFPA 70e Electrical Safety
Arc Flash Protection Training - NFPA 70e Electrical Safety Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq
More informationGuide to Compliance with the Electrical Workplace Safety Standards in the United States
Guide to Compliance with the Electrical Workplace Safety Standards in the United States July 2011/1910DB1102 by Joseph H. Weigel, Product Manager Schneider Electric USA, Inc. Make the most of your energy
More informationElectrical Safety Compliance: NFPA 70E
Electrical Safety Compliance: NFPA 70E From Graybar and Schneider Electric Risks associated with shock and electrocution from inadvertent contact with energized parts have long been recognized as a threat
More informationSUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014
Policy Title: Electrical Safety Work Practice Program Policy Number: UNIV-EHS 430 Policy Approved: January 2014 Policies Superseded: FINA-730 Policy Management Area: Environmental Health and Safety Created/Revision(s):
More informationUNDERSTANDING ELECTRICAL SAFETY RISKS
UNDERSTANDING ELECTRICAL SAFETY RISKS The Electrical Safety Program at BC Safety Authority (BCSA) is responsible for overseeing the safety of electrical systems across British Columbia in accordance with
More informationIndustrial Lighting and Safety
Industrial Lighting and Safety Can Can you see the problem? WMEA Meeting, Calgary, June 9, 2005 Mick Walton Tim Driscoll George Brady Richard Loiselle BJ Electric Sales Shell Canada Syncrude Canada Suncor
More informationNFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions
NFPA 70E Electrical Safety in the Workplace KTR Associates Engineering Solutions Joseph Deane, PE Goal for Today Better understanding of NFPA 70E Raise the awareness of Electrical Hazards Why the sudden
More informationSafety Code. Update on the 25th edition of the Ontario Electrical Safety Code p.4. What s Inside. Ontario Electrical.
News, Views and Updates from the Electrical Safety Authority Winter 011 Safety Code Update on the 5th edition of the Ontario Electrical Safety Code p.4 1-877-ESA-SAFE WWW.ESASAFE.COM What s Inside Ontario
More informationElectrical Safety for Facility Managers and Building Owners
CEU s Copy of Slides Evaluation Form Follow up information Disclaimer. This seminar was produced to help explain the importance and need for electrical safety specifically for Facility Managers. It does
More informationNFPA 70E Elevates Safety. with Heightened Risk Awareness
NFPA 70E 2015 Elevates Safety with Heightened Risk Awareness Next Page NFPA 70E 2015 Elevates Safety with Heightened Risk Awareness: Significant Changes Since 2012 Compel Updated Electrical Safety Training
More informationReducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2
Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2 By: Martin Robinson, CEO of IRISS Group and Level III Thermographer Abstract Every year thousands electrical workers are injured
More informationNFPA 70E Electrical Safety & Arc Flash Training
NFPA 70E Electrical Safety & Arc Flash Training OSHA 1910.332(a) Training, 1910.332(a) Scope. The training requirements contained in this section apply to employees who face a risk of electric shock that
More informationCommercial Renovation Investigation Program
TM News, Views and Updates from the Electrical Safety Authority Summer 2018 Commercial Renovation Investigation Program 445 investigations completed from Oct 2017 Mar 2018 2 regions Durham + Ottawa 260
More informationPromoting Electrical Safety through NFPA 70E Standards Adherence
Promoting Electrical Safety through NFPA 70E Standards Adherence October 2018 Kim Cavaliero-Keller, MELTRIC 1 PROMOTING ELECTRICAL SAFETY INTRODUCTION Electrical injuries claim hundreds of lives each year
More informationElectrical safety tips
Electrical safety tips To help you stay safe when using electricity, ActewAGL has compiled these electrical safety tips. For natural gas safety tips please see ActewAGL s natural gas safety brochure, available
More informationDivision of Fire Safety
STATE OF NEW HAMPSHIRE DEPARTMENT OF SAFETY John J. Barthelmes, Commissioner Division of Fire Safety Office of the State Fire Marshal J. William Degnan, State Fire Marshal Office: 110 Smokey Bear Boulevard,
More informationHARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST
Company: Inspection Completed By: Date: Administrative: 1. Written safety rules/safe job procedures in place 2. OSHA log updated/safety posters displayed 3. Management Safety Policy in place 4. All planned
More informationNECA. Standard for Electrical Safety in the Workplace
4/23/2018 N E R C e- A di st N rib ot ut Fo io r n NECA Significant Changes to the 2018 NFPA 70E Standard for Electrical Safety in the Workplace NFPA 70E Standard for Electrical Safety in the Workplace
More informationElectrical Safety Program
Electrical Safety Program Developed by: The Office of Environmental Health and Safety June, 2010 Table of Contents Introduction 3 Scope..3 Definitions.3-5 CSU Electrical Shop...5 Responsibilities.5-6 Employees.....5
More informationNECA S System Approach to Electrical Safety for NFPA 70E
NECA S System Approach to Electrical Safety for NFPA 70E NECA s Systems Approach to NFPA 70E Easy to understand NFPA 70E employer requirements, Provides Supervisors with key on the job information, De-energize
More informationElectrical Safety Tips. Help us keep you safe.
Electrical Safety Tips. Help us keep you safe. To help you stay safe when using electricity, Evoenergy has compiled these electrical safety tips. For natural gas safety tips please see Evoenergy s natural
More informationNECA S System Approach to Electrical Safety for NFPA 70E
NECA S System Approach to Electrical Safety for NFPA 70E NECA s Systems Approach to NFPA 70E Easy to understand NFPA 70E employer requirements, Provides Supervisors with key on the job information, De
More informationSEL Arc-Flash Solutions
SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment
More informationFIRE AND LIFE SAFETY EDUCATOR II NFPA 1035, Chapter 5, 2015 Edition
Official Skill Sheets for Practical Skills Evaluation Ontario, Canada NFPA 1035, Chapter 5, 2015 Edition National Fire Protection Association Standard for Fire and Life Safety Educator Professional Qualifications
More informationSEL Arc-Flash Solutions
SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment. Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment
More informationElectrical Safety Requirements
Electrical Safety Requirements Purpose This document defines the minimum required control measures to reduce the risk of injury or illness related to electricity. Scope Applicable to all Coca-Cola system
More informationIt should be done through a connection authorization - Should be consistent for all LDCs, to avoid interpretation, public safety risk and liability
Company/ Organization/ Individual Local Distribution Company (LDC) Electro Federation Canada (EFC) Rule # Stakeholder Comment/ Feedback Submitted to ESA & Suggestions for Improvement/ Alternatives 2-005
More informationDEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER
DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER Each year, hundreds of burn injuries and deaths are recorded from workers encountering open flame and high heat or exposure to flash fires and electrical
More informationArc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk
Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk Unrestricted Siemens Industry, Inc. 2015 All rights reserved. usa.siemens.com/arc-flash Everyone is concerned about the risk of Arc
More informationSample Safety Inspection Checklist for Schools
INSPECTION Health and CHECKLIST Safety Committees 1 Sample Safety for Schools School: Date: Inspected By: Each No answer may indicate a problem. Floors and Walkways Are walkways and stairways kept clear
More informationDocument Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022
STANDARD SARNIA REFINERY Document Number: 4000-ZSD-HMSAFESA-007047 Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022 Document Owner: Manager, EH&S Document Contact: Safety Advisor SCOPE
More informationIEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations
IEEE Std 45.5-2014 IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations Presented by Dennis K. Neitzel, CPE, CESCP Director Emeritus Keeping People Safe from Electrical
More informationPROTECTING AGAINST ARC FLASH HAZARDS
PROTECTING AGAINST ARC FLASH HAZARDS Presented by: Andrew J. Fitzpatrick, P.E. Electricity Simply stated electricity is the flow of electrons Electricity is governed by laws: Ohms Law : V=IR Kirchoff s
More informationFire Safety and Prevention: A Resource Guide for Child Welfare Professionals. Presenter Notes
Fire Safety and Prevention: A Resource Guide for Child Welfare Professionals Presenter Notes [Note to Educator: It is recommended that you have the following resources when delivering this presentation:
More informationWHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY
WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY Expanding Home Safety Page 2 INTRODUCTION Smoke alarms, fire extinguishers, emergency escape ladders these are all proven methods for making
More informationHow many time has your company been asked by an owner or customer to work on equipment energized?
How many time has your company been asked by an owner or customer to work on equipment energized? How many times has an electrician choose to not turn a circuit off because it was an inconvenience? How
More informationELECTRICAL BULLETIN
PO Box 697 Halifax, Nova Scotia B3J 2T8 Labour and Workforce Development ELECTRICAL BULLETIN 2011-01 From: David MacLeod,C.E.I.,P.Eng. Pg 1 of 6 Provincial Chief Electrical Inspector Date: January 5,2011
More informationVeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage
VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage www.panduit.com/verisafe What is an Absence of Voltage Tester? Absence of Voltage Testers (AVTs) are permanently-mounted
More informationThe safe way to verify the absence of voltage.
VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage www.panduit.com/verisafe What is an Absence of Voltage Tester? Absence of Voltage Testers (AVTs) are permanently-mounted
More informationLicensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115
Licensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115 An example of wires lead electrician was taping in his palm when he was electrocuted. Kentucky Fatality Assessment and Control
More informationImplementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation
Implementing an Energized Electrical Work Program SESHA Hill Country Chapter May 22, 2009 Brett Jay Davis, PE Zephyr Environmental Corporation bdavis@zephyrenv.com, 512 879-6628 Presentation Outline 1.
More informationElectrical Preventive Maintenance (EPM) Program
Electrical Preventive Maintenance (EPM) Program Only qualified and properly trained persons may work on electric circuit parts or equipment. Such persons shall be capable of working safely and shall be
More informationSystems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa
Systems of inspecting the existing building and the procedures of auditing engineering plans M. Mostafa 2 Agenda 1. Introduction 2. Why inspection? 3. Initial Verification 4. Periodic verification 5. Reference
More informationCompliance without compromise Safety without sacrifice
Compliance without compromise Safety without sacrifice YOUR RESULTS MATTER ClirVu Series IR Windows Safety shouldn t be secondary If Fluke has learned anything in more than 65 years, it s not to compromise
More informationSample Safety Inspection Checklist
INSPECTION HEALTH AND CHECKLIST SAFETY COMMITTEES 1 Sample Safety Workplace: Date: Inspected By: Each No answer may indicate a problem. Yes No FLOORS AND WALKWAYS Are walkways and stairways kept clear
More informationElectrical Safety Program
Electrical Safety Program How Electricity Works Operating an electric switch is like turning on a water faucet. Behind the faucet or switch there must be a source of water or electricity with something
More informationDANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control
DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control INTRODUCTION There are many dangers and hazards which have to be taken into account when entering
More informationWorkplace Inspection Checklist (Office)
Workplace Inspection Checklist (Office) Office location: Inspected by: Worker contacts: Management contacts: Inspection Checklist Areas inspected: Date of inspection: Section 1 Walking Surfaces 1.1 Area
More informationProfessional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...
Professional Seminar The Electrically Safe Workplace Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition Includes Complete Copy of NFPA 70E, 2012 Edition! Learn the Key Concepts of NFPA
More informationSafety Best Practices Manual
CHAPTER 24 OSHA Compliance Checklist te: This is not a comprehensive checklist. It is designed for a typical corporate aviation maintenance department. You must consult the OSHA 1910 Regulations for specific
More informationResidual Current Devices. Switching on to Safety
Residual Current Devices Switching on to Safety Contents What is a Residual Current Device? 2 Types of RCDs 3 Switchboard RCDs 3 1 Residual Current Devices Socket outlet RCDs 4 Portable RCDs 4 Changes
More informationInstallation. Guide. 7 SERIES Professional TurboChef Speedcook Double Oven VDOT730
Installation Guide 7 SERIES Professional TurboChef Speedcook Double Oven VDOT730 Table of Contents Warnings and Important Information 3 Dimensions 6 Specifications 7 Cutout Dimensions 8 General Information
More informationCOMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER
COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER ClirVu Series IR Windows Safety shouldn t be secondary If Fluke has learned anything in more than 65 years, it s not to compromise
More informationSafety requirements for voltage testing instruments
MODEL POLICY Safety requirements for voltage testing instruments 1. FOREWORD 1.1. Approval 1.1.1. This standard is owned by. name of promulgating organization or department 1.1.2. Questions related to
More informationElectrical Safety Program.
University of North Carolina Wilmington Environmental Health & Safety Workplace Safety Electrical Safety Program GENERAL The UNCW Environmental Health & Safety Department (EH&S) is authorized by UNCW Policy
More informationElectrical Hazards and NFPA-70E: Protecting Your Employees
Electrical Hazards and NFPA-70E: Protecting Your Employees Presented By Mark B. Haskins, MS, CSP Practical Safety Solutions, LLC At the CBIA Safety Health and Wellness Conference May 22, 2014 PRESENTATION
More informationHOW-TO CONDUCT A WEEKLY SAFETY MEETING
HOW-TO CONDUCT A WEEKLY SAFETY MEETING 1. Hold the meeting on the job, preferably where everyone can sit and relax. 2. Hold the meeting at the beginning of the shift, right after lunch, or after a break.
More informationGet it Right the First Time Avoid These Commonly Cited Errors
May 2014 Get it Right the First Time Avoid These Commonly Cited Errors By Mark Earley and Mark Hilbert Copyright 2014 National Fire Protection Association. All rights reserved. Good electrical contractors
More informationCombination Type AFCI
Combination Type AFCI Evolution of the Arc Fault Circuit Interrupter www.usa.siemens.com/afci 2 Alarming Statistics According to the U.S. Fire Administration (USFA), an estimated 67,800 fires, 485 deaths,
More informationFire ground electrocution
Fire ground electrocution By VINCENT DUNN Ret Chief FDNY To survive firefighting, firefighters must know how other firefighters have died fighting fires. Electrocution is one cause of fire ground death.
More informationELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED
Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 10 Purpose The purpose of the Electrical Safety program is to set forth procedures for the safe use of electrical equipment,
More informationEnergized Electrical Work Review. Thomas Jefferson National Accelerator Facility
Energized Electrical Work Review Thomas Jefferson National Accelerator Facility February 7-11, 2005 Executive Summary Energized Electrical Work Review Thomas Jefferson National Accelerator Facility February
More informationArc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance
Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance An arc flash can cause serious injury or death to anyone in its path. The National Electrical Code provides
More informationPortable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005
Portable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005 Page 1 of 10 Portable Generator Safety During the process of restoring electric power to a neighborhood Line
More informationApplying the 2012 NFPA 70E. Arc Flash Standard
Applying the 2012 NFPA 70E Arc Flash Standard Suncoast Industrial Services, Inc. 80-6A Industrial Loop N. Orange Park, Fl 32073 904-269-4403 904-269-4404 (fax) wehbysis@suncoastind.com 1 Suncoast Suncoast
More informationNFPA 70E Edition Update
NFPA 70E- 2018 Edition Update Paul Colangelo- STSC, CHST, CET, CRIS National Director of Compliance Programs ClickSafety 1 ASSE Construction Practice Specialty Quarterly Meeting 11/17/2017 Agenda Overview
More informationEmergency Action Plan Leading the Fight
Emergency Action Plan Leading the Fight Subpart E Andy Metsker Loss Prevention Consultant Gibson How Do You Protect Yourself and Your Employees? Identify potential emergencies Develop plans to address
More informationContractor Safety. Workplace Safety & Environmental Division
Contractor Safety Workplace Safety & Environmental Division Click to edit Master title style This information is designed for tradespersons and persons supervising tradespersons who are performing work
More informationTable of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed
Table of Contents 1 Installation 6 1.1 General installation instructions 6 1.2 Electrical requirements 7 1.3 Electrical connection 8 1.4 Cable replacement 10 1.5 Positioning 10 EN Important Safety Instructions
More information6/23/ National Electrical Contractors Association and Intec, Inc.
2012 National Electrical Contractors Association and Intec, Inc. 1 Palmer Hickman Director of Codes and Standards electrical training ALLIANCE Jim Dollard Safety IBEW 98 Objectives Explain why work should
More informationGeneral Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin
The purpose of a monthly self-inspection program is to identify unsafe conditions in the work environment and unsafe employee actions. Management can then correct these safety hazards, reducing the potential
More informationPREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3
Table of Contents Lesson One Article 90: Introduction and Purpose... 3 Lesson Two Articles 100 and 105: Terms and Definitions... 17 Lesson Three Article 110: General Requirements for Work Practices...
More information2014 National Electrical Code & NFPA 70E/Arc Flash
Gain an understanding of the 2014 NEC s latest additions, revisions and changes. Learn the precautions needed when working with and around electricity. People and property need to be safeguarded from the
More informationJPRs related to. NFPA 1021 Standard for Fire Officer Professional Qualifications 2014 Edition. Fire Officer I
JPRs related to NFPA 1021 Standard for Fire Officer Professional Qualifications 4.1.1 Prerequisite Knowledge - (Includes Ethics) Accreditation, Certification, and Certificates Basic Electricity Electrical
More informationHESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove
HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove Jim Dungar, P.E. Principal Engineer Schneider Electric Engineering Services Jim.dungar@schneider-electric.com (920-766-8012)
More informationRefurbishment or New Site Spot Check Checklist
Refurbishment or New Site Spot Check Checklist Site: Date: Coles Group representative: Contractor s name: Where the answer to a question or a number of questions is No, raise a Corrective Action Report
More informationCable Handling, Remote Control Continuous Miners
Cable Handling, Remote Control Continuous Miners When handling the cable within the turning radius of the remote control continuous miner, de-energize the machine and remote control unit according to established
More informationSlide 4. Older adults are at the greatest risk of fire death compared with other age groups.
Presenter Notes Slide 1 Introduce yourself. Thank your audience for the opportunity to talk to them about fire safety. Explain what your presentation will cover: the importance of fire safety, what your
More informationNFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011
NFPA 70E Standard for Electrical Safety in the Workplace EEI Safety and Health Meeting May 2011 NFPA Structure NFPA 70E Technical Committee reports to: NEC Technical Correlating Committee reports to: NFPA
More informationThis section applies to the use of cord- and plug-connected equipment, including cord sets (extension cords).
(B) Portable Electric Equipment. This section applies to the use of cord- and plug-connected equipment, including cord sets (extension cords). (1) Handling. Portable equipment shall be handled in a manner
More informationSecondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August
Secondary Suites Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August 2015 PLANNING & DEVELOPMENT SERVICES Building Permits & Licences 1st Floor, 32315 South Fraser
More informationPhotovoltaic (Solar) Array Installation Guide
Building & Safety Division Community Development Department 7351 Rosanna Street, Gilroy, CA 95020 Phone: 408 846-0451 Fax: 408 846-0429 Visit us: www.cityofgilroy.org Photovoltaic (Solar) Array Installation
More informationNFPA 70E Electrical Safety in the Workplace
NFPA 70E Electrical Safety in the Workplace Objectives What NFPA 70E covers Understand Arc Flash, Incident Energy, & Flash Protection Boundary Standards, Enforcement, & Safe Practices Arc Flash Hazard
More informationInvestigation Report Worker Fatally Injured after Fall from Height November 10, 2014
Investigation Report Worker Fatally Injured after Fall from Height November 10, 2014 F-OHS-079172-OFF1D December 2017 Page 1 of 8 The contents of this report This document reports s (OHS) investigation
More informationWhite Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.
NFPA 70E 2018 Edition Changes and Implications for Personnel Performing Condition Based Maintenance By Rudy Wodrich, P.Eng., MBA, CRL, L1 Thermographer, VP Engineering Services, IRISS Inc. Abstract: The
More informationSafety Systems Review Retail Guidance and specification Version
Systems Review Retail Guidance and specification Version 1 2014 Membership Training Qualifications Audit and Consultancy Policy and Opinion Awards Contents Page Systems Review 1 1 Specification for Systems
More informationCurriculum Vitae - Gregory W. Miller, P.E. June Miller Engineering Services 2205 Barnett Dr. Cedar Park, TX 78613
Curriculum Vitae - Gregory W. Miller, P.E. June 2014 2205 Barnett Dr. Cedar Park, TX 78613 E-Mail: gmiller@forensicpe.com Phone: 512-986-5396 Cell: 512-401-6377 Overview and Forensic Specializations Construction
More informationExit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long and tragic
More informationManifold Installation Controller MIC-180. Installation and Operation Instructions
Manifold Installation Controller MIC-180 Installation and Operation Instructions For Use With Rheem-Ruud and Paloma Commercial Tankless Water Heaters Table of Contents Safety Information... 1-2 Manifold
More informationThe Basics Arc Flash Protection
2008 The Basics Arc Flash Protection An arcing fault can be defined as the flow of current through a path where it is not intended to flow Rob Vajko 12/15/2008 What is an Arc Flash? An arc flash starts
More informationSummary. firefighter training in Since that time the firefighter had attended semi-annual
Summary On August 25, 2005 a live fire training exercise was conducted at a North Carolina County airport. Personnel involved in the training evolution were three employees of the airport who were employed
More informationCODE RED (FIRE) Site:
Saskatoon Health Region is responsible for emergency preparedness planning and response to emergency situations and disasters, in addition to providing health care services for consumers during these times.
More informationtechnology using advanced to reduce electrical fires arc fault circuit interrupters
arc fault circuit interrupters using advanced technology to reduce electrical fires NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION Low Voltage Distribution Equipment Section I NTRODUCTION Arc Fault Circuit
More informationresearch highlight Canadian Housing Fire Statistics Findings
research highlight August 2004 Socio-economic Series 04-004 Introduction The project, completed under the CMHC External Research Program, develops benchmarks and indicators related to fire losses in housing
More informationFacility Risk Assessment Questionnaire
Facility Risk Assessment Questionnaire ServiceMaster anytime provides this safety information free of charge. These materials are provided as a service to our clients and 866 Recover enrollees and is for
More informationNATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY
A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work -
More informationA Guide to FIRE Recovery
A Guide to FIRE Recovery After we leave the emergency scene, what should you do next? Mississauga Fire & Emergency Services in community partnership with Birnie HOME SAFE Our FIRE Family Helping Your Family
More informationContent Rev
SASKPOWER RED TAG PROGRAM USER MANUAL Content Rev. 2008-11-17 INDEX Preface 2 Scope 2 Definitions 2 Notification 3 Reporting Procedures 3 Returning the Corrected Red Tag Defect 4 Sample Red Tag (two sided
More information