ONTARIO Electrical Safety Report. 10th Edition

Size: px
Start display at page:

Download "ONTARIO Electrical Safety Report. 10th Edition"

Transcription

1 ONTARIO Electrical Safety Report 10th Edition 2010 OESR vmesf1.0 Electrical Safety Authority 2012

2 Electrical Engineers and Consultants perhaps not understanding all of the applicable regulations for Mines & Industrial Plants. Electricians and Electrical Contractors not up to date on regulations due to lack of upgrade training. Huge projects are putting significant demands on inspection oversight. Unapproved equipment being sold and incorporated into projects. Installations being performed that are not meeting minimum standards which affect reliability and safety OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

3 ESA Service Review of pre tender Engineered plans and specs Field review of installation Product Approvals Advisory Services Documentation Benefit to Mines Reduce or eliminate change orders related to errors in electrical design Ensure field installation does not sacrifice design integrity Ensure that equipment is legal for use and suitable for your operation Information portal on application of Codes & Regulations Understand amount of defects being installed by Contractor and project division OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

4 ESA Service Cold eye review of existing electrical system Plan reviews Advisory Services Code & Reg. Training CSA Z462 Product Approvals Benefit to Mines Identify deviations from minimum standards that will affect reliability and safety Ensure new proposed installations meet the Code and Regs. Ask the questions regarding elect. Maintenance and new work, eliminating rework Ensure qualified staff know how to install and maintain correctly. Improves system integrity Understanding Arc Flash and training on proper selection/application of PPE Approve equipment that is found to be unapproved OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

5 ESA sponsored initiative within the Ontario mining community Venue bringing key electrical safety stakeholders together to: Share important safety initiatives; Share interpretation of codes and standards to improve consistency; Identify current trends, weaknesses and gaps in mining electrical safety; Drive Industry Change for enhanced Electrical Safety; Meetings held bi annually, Spring & Fall OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

6 e plan Solution Benefits & Features... Compliance with CSA Z462, Workplace Electrical Safety Safe Work Packages Electrical Task Safety Summaries & Job Briefing Checklists Continuous support & updates from the ESA Records plant specific equipment limits of approach/ arc flash data, and employee & contractor data (e.g. trades, training & qualifications) Adapts well to different user needs Integrates custom features OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

7 ESA receives data from various resources to compile this report. Ontario Coroner s Office Ministry of Labour (MOL) Office of the Fire Marshal (OFM) Workers Safety and Insurance Board of Ontario (WSIB) Canadian Institute for Health Information (CIHI) Statistics Canada At the time of writing, the Coroner s reports for 2009 and 2010 are only partially completed due to pending investigations and confirmations. Where there are discrepancies in the number of fatalities reported by MOL and ESA, ESA uses the data provided by the Coroner. Electrocution an accidental death caused by the contact with electricity. Fatality an injury resulting in a death

8

9 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

10

11

12

13

14 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

15

16

17 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

18

19

20 An arc flash event injured three workers in a pulp and paper manufacturing facility when they were replacing a power box in the electrical room OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

21 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

22 The two electricians suffered first, second and third degree burns. A student who was watching them suffered first degree burns Owner Operator fined $125,000 after workers and student injured OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

23 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO

24

25

26

27 Ten storey building Fire in a ground floor, one bedroom apartment Seriously injured one person Cause: portable heater and its extension cord

28

29 OESR vmesf1.0 Electrical Safety Authority 2012 GETTING TO ZERO ZER

30

31

32 ring the investigation, ESA found: The primary conductor was within 4 m of the house. Horizontal clearance met the 2009 OESC. 5 aluminum extension ladders were set up against the house. Workers were leap frogging them as they installed the soffit. Victim attempted to move one of the extension ladders and it touched the energized primary line. He was killed instantly. Burn marks can be seen at the point of contact on the power line and ladder. No disconnection request was made by the workers or homeowner.

33

34 Powerline contacts Electrical workers Product safety Aging infrastructure New wiring

35 GETTING TO

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth by Mark Hilbert and Laura L. Hildreth AND THE ELECTRICAL INSPECTOR May is National Electrical Safety Month, an annual effort to help reduce electricallyrelated fatalities, injuries, and property loss both

More information

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards v2-5058-co900h Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 1 Agenda 1. Background 2. Related Electrical

More information

Arc Flash Protection Training - NFPA 70e Electrical Safety

Arc Flash Protection Training - NFPA 70e Electrical Safety Arc Flash Protection Training - NFPA 70e Electrical Safety Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq

More information

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Guide to Compliance with the Electrical Workplace Safety Standards in the United States Guide to Compliance with the Electrical Workplace Safety Standards in the United States July 2011/1910DB1102 by Joseph H. Weigel, Product Manager Schneider Electric USA, Inc. Make the most of your energy

More information

Electrical Safety Compliance: NFPA 70E

Electrical Safety Compliance: NFPA 70E Electrical Safety Compliance: NFPA 70E From Graybar and Schneider Electric Risks associated with shock and electrocution from inadvertent contact with energized parts have long been recognized as a threat

More information

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014 Policy Title: Electrical Safety Work Practice Program Policy Number: UNIV-EHS 430 Policy Approved: January 2014 Policies Superseded: FINA-730 Policy Management Area: Environmental Health and Safety Created/Revision(s):

More information

UNDERSTANDING ELECTRICAL SAFETY RISKS

UNDERSTANDING ELECTRICAL SAFETY RISKS UNDERSTANDING ELECTRICAL SAFETY RISKS The Electrical Safety Program at BC Safety Authority (BCSA) is responsible for overseeing the safety of electrical systems across British Columbia in accordance with

More information

Industrial Lighting and Safety

Industrial Lighting and Safety Industrial Lighting and Safety Can Can you see the problem? WMEA Meeting, Calgary, June 9, 2005 Mick Walton Tim Driscoll George Brady Richard Loiselle BJ Electric Sales Shell Canada Syncrude Canada Suncor

More information

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions NFPA 70E Electrical Safety in the Workplace KTR Associates Engineering Solutions Joseph Deane, PE Goal for Today Better understanding of NFPA 70E Raise the awareness of Electrical Hazards Why the sudden

More information

Safety Code. Update on the 25th edition of the Ontario Electrical Safety Code p.4. What s Inside. Ontario Electrical.

Safety Code. Update on the 25th edition of the Ontario Electrical Safety Code p.4. What s Inside. Ontario Electrical. News, Views and Updates from the Electrical Safety Authority Winter 011 Safety Code Update on the 5th edition of the Ontario Electrical Safety Code p.4 1-877-ESA-SAFE WWW.ESASAFE.COM What s Inside Ontario

More information

Electrical Safety for Facility Managers and Building Owners

Electrical Safety for Facility Managers and Building Owners CEU s Copy of Slides Evaluation Form Follow up information Disclaimer. This seminar was produced to help explain the importance and need for electrical safety specifically for Facility Managers. It does

More information

NFPA 70E Elevates Safety. with Heightened Risk Awareness

NFPA 70E Elevates Safety. with Heightened Risk Awareness NFPA 70E 2015 Elevates Safety with Heightened Risk Awareness Next Page NFPA 70E 2015 Elevates Safety with Heightened Risk Awareness: Significant Changes Since 2012 Compel Updated Electrical Safety Training

More information

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2 Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2 By: Martin Robinson, CEO of IRISS Group and Level III Thermographer Abstract Every year thousands electrical workers are injured

More information

NFPA 70E Electrical Safety & Arc Flash Training

NFPA 70E Electrical Safety & Arc Flash Training NFPA 70E Electrical Safety & Arc Flash Training OSHA 1910.332(a) Training, 1910.332(a) Scope. The training requirements contained in this section apply to employees who face a risk of electric shock that

More information

Commercial Renovation Investigation Program

Commercial Renovation Investigation Program TM News, Views and Updates from the Electrical Safety Authority Summer 2018 Commercial Renovation Investigation Program 445 investigations completed from Oct 2017 Mar 2018 2 regions Durham + Ottawa 260

More information

Promoting Electrical Safety through NFPA 70E Standards Adherence

Promoting Electrical Safety through NFPA 70E Standards Adherence Promoting Electrical Safety through NFPA 70E Standards Adherence October 2018 Kim Cavaliero-Keller, MELTRIC 1 PROMOTING ELECTRICAL SAFETY INTRODUCTION Electrical injuries claim hundreds of lives each year

More information

Electrical safety tips

Electrical safety tips Electrical safety tips To help you stay safe when using electricity, ActewAGL has compiled these electrical safety tips. For natural gas safety tips please see ActewAGL s natural gas safety brochure, available

More information

Division of Fire Safety

Division of Fire Safety STATE OF NEW HAMPSHIRE DEPARTMENT OF SAFETY John J. Barthelmes, Commissioner Division of Fire Safety Office of the State Fire Marshal J. William Degnan, State Fire Marshal Office: 110 Smokey Bear Boulevard,

More information

HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST

HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST Company: Inspection Completed By: Date: Administrative: 1. Written safety rules/safe job procedures in place 2. OSHA log updated/safety posters displayed 3. Management Safety Policy in place 4. All planned

More information

NECA. Standard for Electrical Safety in the Workplace

NECA. Standard for Electrical Safety in the Workplace 4/23/2018 N E R C e- A di st N rib ot ut Fo io r n NECA Significant Changes to the 2018 NFPA 70E Standard for Electrical Safety in the Workplace NFPA 70E Standard for Electrical Safety in the Workplace

More information

Electrical Safety Program

Electrical Safety Program Electrical Safety Program Developed by: The Office of Environmental Health and Safety June, 2010 Table of Contents Introduction 3 Scope..3 Definitions.3-5 CSU Electrical Shop...5 Responsibilities.5-6 Employees.....5

More information

NECA S System Approach to Electrical Safety for NFPA 70E

NECA S System Approach to Electrical Safety for NFPA 70E NECA S System Approach to Electrical Safety for NFPA 70E NECA s Systems Approach to NFPA 70E Easy to understand NFPA 70E employer requirements, Provides Supervisors with key on the job information, De-energize

More information

Electrical Safety Tips. Help us keep you safe.

Electrical Safety Tips. Help us keep you safe. Electrical Safety Tips. Help us keep you safe. To help you stay safe when using electricity, Evoenergy has compiled these electrical safety tips. For natural gas safety tips please see Evoenergy s natural

More information

NECA S System Approach to Electrical Safety for NFPA 70E

NECA S System Approach to Electrical Safety for NFPA 70E NECA S System Approach to Electrical Safety for NFPA 70E NECA s Systems Approach to NFPA 70E Easy to understand NFPA 70E employer requirements, Provides Supervisors with key on the job information, De

More information

SEL Arc-Flash Solutions

SEL Arc-Flash Solutions SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment

More information

FIRE AND LIFE SAFETY EDUCATOR II NFPA 1035, Chapter 5, 2015 Edition

FIRE AND LIFE SAFETY EDUCATOR II NFPA 1035, Chapter 5, 2015 Edition Official Skill Sheets for Practical Skills Evaluation Ontario, Canada NFPA 1035, Chapter 5, 2015 Edition National Fire Protection Association Standard for Fire and Life Safety Educator Professional Qualifications

More information

SEL Arc-Flash Solutions

SEL Arc-Flash Solutions SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment. Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment

More information

Electrical Safety Requirements

Electrical Safety Requirements Electrical Safety Requirements Purpose This document defines the minimum required control measures to reduce the risk of injury or illness related to electricity. Scope Applicable to all Coca-Cola system

More information

It should be done through a connection authorization - Should be consistent for all LDCs, to avoid interpretation, public safety risk and liability

It should be done through a connection authorization - Should be consistent for all LDCs, to avoid interpretation, public safety risk and liability Company/ Organization/ Individual Local Distribution Company (LDC) Electro Federation Canada (EFC) Rule # Stakeholder Comment/ Feedback Submitted to ESA & Suggestions for Improvement/ Alternatives 2-005

More information

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER Each year, hundreds of burn injuries and deaths are recorded from workers encountering open flame and high heat or exposure to flash fires and electrical

More information

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk Unrestricted Siemens Industry, Inc. 2015 All rights reserved. usa.siemens.com/arc-flash Everyone is concerned about the risk of Arc

More information

Sample Safety Inspection Checklist for Schools

Sample Safety Inspection Checklist for Schools INSPECTION Health and CHECKLIST Safety Committees 1 Sample Safety for Schools School: Date: Inspected By: Each No answer may indicate a problem. Floors and Walkways Are walkways and stairways kept clear

More information

Document Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022

Document Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022 STANDARD SARNIA REFINERY Document Number: 4000-ZSD-HMSAFESA-007047 Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022 Document Owner: Manager, EH&S Document Contact: Safety Advisor SCOPE

More information

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations IEEE Std 45.5-2014 IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations Presented by Dennis K. Neitzel, CPE, CESCP Director Emeritus Keeping People Safe from Electrical

More information

PROTECTING AGAINST ARC FLASH HAZARDS

PROTECTING AGAINST ARC FLASH HAZARDS PROTECTING AGAINST ARC FLASH HAZARDS Presented by: Andrew J. Fitzpatrick, P.E. Electricity Simply stated electricity is the flow of electrons Electricity is governed by laws: Ohms Law : V=IR Kirchoff s

More information

Fire Safety and Prevention: A Resource Guide for Child Welfare Professionals. Presenter Notes

Fire Safety and Prevention: A Resource Guide for Child Welfare Professionals. Presenter Notes Fire Safety and Prevention: A Resource Guide for Child Welfare Professionals Presenter Notes [Note to Educator: It is recommended that you have the following resources when delivering this presentation:

More information

WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY

WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY Expanding Home Safety Page 2 INTRODUCTION Smoke alarms, fire extinguishers, emergency escape ladders these are all proven methods for making

More information

How many time has your company been asked by an owner or customer to work on equipment energized?

How many time has your company been asked by an owner or customer to work on equipment energized? How many time has your company been asked by an owner or customer to work on equipment energized? How many times has an electrician choose to not turn a circuit off because it was an inconvenience? How

More information

ELECTRICAL BULLETIN

ELECTRICAL BULLETIN PO Box 697 Halifax, Nova Scotia B3J 2T8 Labour and Workforce Development ELECTRICAL BULLETIN 2011-01 From: David MacLeod,C.E.I.,P.Eng. Pg 1 of 6 Provincial Chief Electrical Inspector Date: January 5,2011

More information

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage www.panduit.com/verisafe What is an Absence of Voltage Tester? Absence of Voltage Testers (AVTs) are permanently-mounted

More information

The safe way to verify the absence of voltage.

The safe way to verify the absence of voltage. VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage www.panduit.com/verisafe What is an Absence of Voltage Tester? Absence of Voltage Testers (AVTs) are permanently-mounted

More information

Licensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115

Licensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115 Licensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115 An example of wires lead electrician was taping in his palm when he was electrocuted. Kentucky Fatality Assessment and Control

More information

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation Implementing an Energized Electrical Work Program SESHA Hill Country Chapter May 22, 2009 Brett Jay Davis, PE Zephyr Environmental Corporation bdavis@zephyrenv.com, 512 879-6628 Presentation Outline 1.

More information

Electrical Preventive Maintenance (EPM) Program

Electrical Preventive Maintenance (EPM) Program Electrical Preventive Maintenance (EPM) Program Only qualified and properly trained persons may work on electric circuit parts or equipment. Such persons shall be capable of working safely and shall be

More information

Systems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa

Systems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa Systems of inspecting the existing building and the procedures of auditing engineering plans M. Mostafa 2 Agenda 1. Introduction 2. Why inspection? 3. Initial Verification 4. Periodic verification 5. Reference

More information

Compliance without compromise Safety without sacrifice

Compliance without compromise Safety without sacrifice Compliance without compromise Safety without sacrifice YOUR RESULTS MATTER ClirVu Series IR Windows Safety shouldn t be secondary If Fluke has learned anything in more than 65 years, it s not to compromise

More information

Sample Safety Inspection Checklist

Sample Safety Inspection Checklist INSPECTION HEALTH AND CHECKLIST SAFETY COMMITTEES 1 Sample Safety Workplace: Date: Inspected By: Each No answer may indicate a problem. Yes No FLOORS AND WALKWAYS Are walkways and stairways kept clear

More information

Electrical Safety Program

Electrical Safety Program Electrical Safety Program How Electricity Works Operating an electric switch is like turning on a water faucet. Behind the faucet or switch there must be a source of water or electricity with something

More information

DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control

DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control INTRODUCTION There are many dangers and hazards which have to be taken into account when entering

More information

Workplace Inspection Checklist (Office)

Workplace Inspection Checklist (Office) Workplace Inspection Checklist (Office) Office location: Inspected by: Worker contacts: Management contacts: Inspection Checklist Areas inspected: Date of inspection: Section 1 Walking Surfaces 1.1 Area

More information

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ... Professional Seminar The Electrically Safe Workplace Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition Includes Complete Copy of NFPA 70E, 2012 Edition! Learn the Key Concepts of NFPA

More information

Safety Best Practices Manual

Safety Best Practices Manual CHAPTER 24 OSHA Compliance Checklist te: This is not a comprehensive checklist. It is designed for a typical corporate aviation maintenance department. You must consult the OSHA 1910 Regulations for specific

More information

Residual Current Devices. Switching on to Safety

Residual Current Devices. Switching on to Safety Residual Current Devices Switching on to Safety Contents What is a Residual Current Device? 2 Types of RCDs 3 Switchboard RCDs 3 1 Residual Current Devices Socket outlet RCDs 4 Portable RCDs 4 Changes

More information

Installation. Guide. 7 SERIES Professional TurboChef Speedcook Double Oven VDOT730

Installation. Guide. 7 SERIES Professional TurboChef Speedcook Double Oven VDOT730 Installation Guide 7 SERIES Professional TurboChef Speedcook Double Oven VDOT730 Table of Contents Warnings and Important Information 3 Dimensions 6 Specifications 7 Cutout Dimensions 8 General Information

More information

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER ClirVu Series IR Windows Safety shouldn t be secondary If Fluke has learned anything in more than 65 years, it s not to compromise

More information

Safety requirements for voltage testing instruments

Safety requirements for voltage testing instruments MODEL POLICY Safety requirements for voltage testing instruments 1. FOREWORD 1.1. Approval 1.1.1. This standard is owned by. name of promulgating organization or department 1.1.2. Questions related to

More information

Electrical Safety Program.

Electrical Safety Program. University of North Carolina Wilmington Environmental Health & Safety Workplace Safety Electrical Safety Program GENERAL The UNCW Environmental Health & Safety Department (EH&S) is authorized by UNCW Policy

More information

Electrical Hazards and NFPA-70E: Protecting Your Employees

Electrical Hazards and NFPA-70E: Protecting Your Employees Electrical Hazards and NFPA-70E: Protecting Your Employees Presented By Mark B. Haskins, MS, CSP Practical Safety Solutions, LLC At the CBIA Safety Health and Wellness Conference May 22, 2014 PRESENTATION

More information

HOW-TO CONDUCT A WEEKLY SAFETY MEETING

HOW-TO CONDUCT A WEEKLY SAFETY MEETING HOW-TO CONDUCT A WEEKLY SAFETY MEETING 1. Hold the meeting on the job, preferably where everyone can sit and relax. 2. Hold the meeting at the beginning of the shift, right after lunch, or after a break.

More information

Get it Right the First Time Avoid These Commonly Cited Errors

Get it Right the First Time Avoid These Commonly Cited Errors May 2014 Get it Right the First Time Avoid These Commonly Cited Errors By Mark Earley and Mark Hilbert Copyright 2014 National Fire Protection Association. All rights reserved. Good electrical contractors

More information

Combination Type AFCI

Combination Type AFCI Combination Type AFCI Evolution of the Arc Fault Circuit Interrupter www.usa.siemens.com/afci 2 Alarming Statistics According to the U.S. Fire Administration (USFA), an estimated 67,800 fires, 485 deaths,

More information

Fire ground electrocution

Fire ground electrocution Fire ground electrocution By VINCENT DUNN Ret Chief FDNY To survive firefighting, firefighters must know how other firefighters have died fighting fires. Electrocution is one cause of fire ground death.

More information

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 10 Purpose The purpose of the Electrical Safety program is to set forth procedures for the safe use of electrical equipment,

More information

Energized Electrical Work Review. Thomas Jefferson National Accelerator Facility

Energized Electrical Work Review. Thomas Jefferson National Accelerator Facility Energized Electrical Work Review Thomas Jefferson National Accelerator Facility February 7-11, 2005 Executive Summary Energized Electrical Work Review Thomas Jefferson National Accelerator Facility February

More information

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance An arc flash can cause serious injury or death to anyone in its path. The National Electrical Code provides

More information

Portable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005

Portable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005 Portable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005 Page 1 of 10 Portable Generator Safety During the process of restoring electric power to a neighborhood Line

More information

Applying the 2012 NFPA 70E. Arc Flash Standard

Applying the 2012 NFPA 70E. Arc Flash Standard Applying the 2012 NFPA 70E Arc Flash Standard Suncoast Industrial Services, Inc. 80-6A Industrial Loop N. Orange Park, Fl 32073 904-269-4403 904-269-4404 (fax) wehbysis@suncoastind.com 1 Suncoast Suncoast

More information

NFPA 70E Edition Update

NFPA 70E Edition Update NFPA 70E- 2018 Edition Update Paul Colangelo- STSC, CHST, CET, CRIS National Director of Compliance Programs ClickSafety 1 ASSE Construction Practice Specialty Quarterly Meeting 11/17/2017 Agenda Overview

More information

Emergency Action Plan Leading the Fight

Emergency Action Plan Leading the Fight Emergency Action Plan Leading the Fight Subpart E Andy Metsker Loss Prevention Consultant Gibson How Do You Protect Yourself and Your Employees? Identify potential emergencies Develop plans to address

More information

Contractor Safety. Workplace Safety & Environmental Division

Contractor Safety. Workplace Safety & Environmental Division Contractor Safety Workplace Safety & Environmental Division Click to edit Master title style This information is designed for tradespersons and persons supervising tradespersons who are performing work

More information

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed Table of Contents 1 Installation 6 1.1 General installation instructions 6 1.2 Electrical requirements 7 1.3 Electrical connection 8 1.4 Cable replacement 10 1.5 Positioning 10 EN Important Safety Instructions

More information

6/23/ National Electrical Contractors Association and Intec, Inc.

6/23/ National Electrical Contractors Association and Intec, Inc. 2012 National Electrical Contractors Association and Intec, Inc. 1 Palmer Hickman Director of Codes and Standards electrical training ALLIANCE Jim Dollard Safety IBEW 98 Objectives Explain why work should

More information

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin The purpose of a monthly self-inspection program is to identify unsafe conditions in the work environment and unsafe employee actions. Management can then correct these safety hazards, reducing the potential

More information

PREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3

PREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3 Table of Contents Lesson One Article 90: Introduction and Purpose... 3 Lesson Two Articles 100 and 105: Terms and Definitions... 17 Lesson Three Article 110: General Requirements for Work Practices...

More information

2014 National Electrical Code & NFPA 70E/Arc Flash

2014 National Electrical Code & NFPA 70E/Arc Flash Gain an understanding of the 2014 NEC s latest additions, revisions and changes. Learn the precautions needed when working with and around electricity. People and property need to be safeguarded from the

More information

JPRs related to. NFPA 1021 Standard for Fire Officer Professional Qualifications 2014 Edition. Fire Officer I

JPRs related to. NFPA 1021 Standard for Fire Officer Professional Qualifications 2014 Edition. Fire Officer I JPRs related to NFPA 1021 Standard for Fire Officer Professional Qualifications 4.1.1 Prerequisite Knowledge - (Includes Ethics) Accreditation, Certification, and Certificates Basic Electricity Electrical

More information

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove Jim Dungar, P.E. Principal Engineer Schneider Electric Engineering Services Jim.dungar@schneider-electric.com (920-766-8012)

More information

Refurbishment or New Site Spot Check Checklist

Refurbishment or New Site Spot Check Checklist Refurbishment or New Site Spot Check Checklist Site: Date: Coles Group representative: Contractor s name: Where the answer to a question or a number of questions is No, raise a Corrective Action Report

More information

Cable Handling, Remote Control Continuous Miners

Cable Handling, Remote Control Continuous Miners Cable Handling, Remote Control Continuous Miners When handling the cable within the turning radius of the remote control continuous miner, de-energize the machine and remote control unit according to established

More information

Slide 4. Older adults are at the greatest risk of fire death compared with other age groups.

Slide 4. Older adults are at the greatest risk of fire death compared with other age groups. Presenter Notes Slide 1 Introduce yourself. Thank your audience for the opportunity to talk to them about fire safety. Explain what your presentation will cover: the importance of fire safety, what your

More information

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011 NFPA 70E Standard for Electrical Safety in the Workplace EEI Safety and Health Meeting May 2011 NFPA Structure NFPA 70E Technical Committee reports to: NEC Technical Correlating Committee reports to: NFPA

More information

This section applies to the use of cord- and plug-connected equipment, including cord sets (extension cords).

This section applies to the use of cord- and plug-connected equipment, including cord sets (extension cords). (B) Portable Electric Equipment. This section applies to the use of cord- and plug-connected equipment, including cord sets (extension cords). (1) Handling. Portable equipment shall be handled in a manner

More information

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August Secondary Suites Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August 2015 PLANNING & DEVELOPMENT SERVICES Building Permits & Licences 1st Floor, 32315 South Fraser

More information

Photovoltaic (Solar) Array Installation Guide

Photovoltaic (Solar) Array Installation Guide Building & Safety Division Community Development Department 7351 Rosanna Street, Gilroy, CA 95020 Phone: 408 846-0451 Fax: 408 846-0429 Visit us: www.cityofgilroy.org Photovoltaic (Solar) Array Installation

More information

NFPA 70E Electrical Safety in the Workplace

NFPA 70E Electrical Safety in the Workplace NFPA 70E Electrical Safety in the Workplace Objectives What NFPA 70E covers Understand Arc Flash, Incident Energy, & Flash Protection Boundary Standards, Enforcement, & Safe Practices Arc Flash Hazard

More information

Investigation Report Worker Fatally Injured after Fall from Height November 10, 2014

Investigation Report Worker Fatally Injured after Fall from Height November 10, 2014 Investigation Report Worker Fatally Injured after Fall from Height November 10, 2014 F-OHS-079172-OFF1D December 2017 Page 1 of 8 The contents of this report This document reports s (OHS) investigation

More information

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss. NFPA 70E 2018 Edition Changes and Implications for Personnel Performing Condition Based Maintenance By Rudy Wodrich, P.Eng., MBA, CRL, L1 Thermographer, VP Engineering Services, IRISS Inc. Abstract: The

More information

Safety Systems Review Retail Guidance and specification Version

Safety Systems Review Retail Guidance and specification Version Systems Review Retail Guidance and specification Version 1 2014 Membership Training Qualifications Audit and Consultancy Policy and Opinion Awards Contents Page Systems Review 1 1 Specification for Systems

More information

Curriculum Vitae - Gregory W. Miller, P.E. June Miller Engineering Services 2205 Barnett Dr. Cedar Park, TX 78613

Curriculum Vitae - Gregory W. Miller, P.E. June Miller Engineering Services 2205 Barnett Dr. Cedar Park, TX 78613 Curriculum Vitae - Gregory W. Miller, P.E. June 2014 2205 Barnett Dr. Cedar Park, TX 78613 E-Mail: gmiller@forensicpe.com Phone: 512-986-5396 Cell: 512-401-6377 Overview and Forensic Specializations Construction

More information

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long and tragic

More information

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Manifold Installation Controller MIC-180. Installation and Operation Instructions Manifold Installation Controller MIC-180 Installation and Operation Instructions For Use With Rheem-Ruud and Paloma Commercial Tankless Water Heaters Table of Contents Safety Information... 1-2 Manifold

More information

The Basics Arc Flash Protection

The Basics Arc Flash Protection 2008 The Basics Arc Flash Protection An arcing fault can be defined as the flow of current through a path where it is not intended to flow Rob Vajko 12/15/2008 What is an Arc Flash? An arc flash starts

More information

Summary. firefighter training in Since that time the firefighter had attended semi-annual

Summary. firefighter training in Since that time the firefighter had attended semi-annual Summary On August 25, 2005 a live fire training exercise was conducted at a North Carolina County airport. Personnel involved in the training evolution were three employees of the airport who were employed

More information

CODE RED (FIRE) Site:

CODE RED (FIRE) Site: Saskatoon Health Region is responsible for emergency preparedness planning and response to emergency situations and disasters, in addition to providing health care services for consumers during these times.

More information

technology using advanced to reduce electrical fires arc fault circuit interrupters

technology using advanced to reduce electrical fires arc fault circuit interrupters arc fault circuit interrupters using advanced technology to reduce electrical fires NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION Low Voltage Distribution Equipment Section I NTRODUCTION Arc Fault Circuit

More information

research highlight Canadian Housing Fire Statistics Findings

research highlight Canadian Housing Fire Statistics Findings research highlight August 2004 Socio-economic Series 04-004 Introduction The project, completed under the CMHC External Research Program, develops benchmarks and indicators related to fire losses in housing

More information

Facility Risk Assessment Questionnaire

Facility Risk Assessment Questionnaire Facility Risk Assessment Questionnaire ServiceMaster anytime provides this safety information free of charge. These materials are provided as a service to our clients and 866 Recover enrollees and is for

More information

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work -

More information

A Guide to FIRE Recovery

A Guide to FIRE Recovery A Guide to FIRE Recovery After we leave the emergency scene, what should you do next? Mississauga Fire & Emergency Services in community partnership with Birnie HOME SAFE Our FIRE Family Helping Your Family

More information

Content Rev

Content Rev SASKPOWER RED TAG PROGRAM USER MANUAL Content Rev. 2008-11-17 INDEX Preface 2 Scope 2 Definitions 2 Notification 3 Reporting Procedures 3 Returning the Corrected Red Tag Defect 4 Sample Red Tag (two sided

More information