Optical Beam Smoke Detector RK90R - RK90RS

Size: px
Start display at page:

Download "Optical Beam Smoke Detector RK90R - RK90RS"

Transcription

1

2 Optical Beam Smoke Detector RK90R - RK90RS TECHNICAL INFORMATION APPLICATIONS museums churches art galleries libraries hotels shops cinemas computer rooms control rooms storehouses, etc. The RK90R it's a reflection Beam Smoke Detector. Its operation is based on the relation between the smoke present in an environment, generated by the starting of a fire, and the infrared beam emitted by the device and reflected by a special optical reflector. It is also able to detect the presence of vapour and fog. A fundamental feature of this detector is the ability to detect the presence of both white smoke and black smoke even if they are little dense. This detector has been designed for applications where the aesthetics, the small dimensions, the possibility of remote visualization of the signal and the simplicity of use have primary importance. So RK90R is particularly suitable to be installed in artistic environments like museums, churches, art galleries and in offices, hotels etc. TECHNICAL FEATURES a single detector can cover an area up to 750 mq. installation is easy and quick the internal electronics are controlled by a microprocessor a special function automatically compensates the signal drift caused by the opacity on the optical parts, generated by dust and dirt, minimizing the maintenance needs the detector RK90R has 2 separated circuits for smoke detection: Oscuration and Turbulence the detector RK90RS has only the circuits for smoke detection: Oscuration RK90R - 3 relay outputs: Alarm, Turbulence, Fault RK90RS - 2 relay outputs: Alarm, Fault analog output that allows to remotely visualize the detector's signal level using an optional led bar module maintenance is easy and not frequent very low operational costs - cost effective simplified allignment with signal level led indication EN54-12 CPD and VDS certified CERTIFIED EN54-12 VDS CPD

3 OPERATION TECHNICAL DATA The RK90R it's an Optical Beam Smoke Detector suited with 2 separated detection circuits based on the principles of Obscuration and Turbulence (RK90R) Oscuration The device has to be installed at one end of the area to be protected just under the level of the ceiling and the special reflector (FX) must be installed at the other end. When a fire begins, it produces smoke that rises up and intercepts the infrared beam of the detector. This causes an attenuation of the received signal that, if the threshold level is reached, will activate its alarm relay that can drive suitable alarm signalling devices. Turbulence Normally, during the starting phase of a fire, smoke clouds are generated and the thermal energy of the fire (heat) produces bubbles of hot air that rise up. When these clouds and bubbles intercept the beam emitted by the detector, they cause a perturbation in it because they modify the optical-physical caratheristics of the transmission medium of the beam. These variations are obviously time related. A suitable circuit has been designed to detect these variations and when they reach the preset amplitude and time duration levels, an alarm signal is generated. The advantage of using the turbulence detection circuit it's a quicker detection of the fire, because it is revealed in it's beginning. So RK90R, with this circuit, reveals dinamically both the smoke clouds by the starting of the fire and, in case the fire generates flames and so thermal energy, the perturbation phenomena produced by the combustion process. Optical Reflectors 4 types of optical reflectors can be used with RK90R: FX01 - FX02 - FX03 - FX07. The reflectors choice has to be done according to the optical path lenght (distance beween detector and reflector) and to aesthetic needs of the environment. The FX07 it's particularly suitable to be installed in artistic places (museums, art galleries, etc). Options ZC-01 - It is a optional base that facilitates the installation in the 01 is equiped of breakable holes on the sides. SUP90 - It is a adjustable support that allows the orientation of the optical beam in various directions. It is useful in the case of installation of the detector of the detector in an angle of the room. BLP-90 - Laser Pointer - eliminates the need to use a lamp for optical alignment detector-reflector - the pointer is installed and collimated in the laboratory - the time of installation of the detector is drastically reduced - just point the laser beam on the reflector to have optics aligned. 01 case in which the cable within pipe guide is outside of the wall. The ZC- ZC- Models: RK90R RK90RS (without Turbulence) Type: Reflection Optical Beam Smoke Detector Manufacturer: EDS srl - V. Cà Nova Zampieri S.G. Lupatoto - Verona - ITALY Power Supply: 12/24 Vdc Power Supply Range: Vdc Optical Path Lenght: 3-12 m with FX-07 reflector m with FX-01 reflector m with FX-02 reflector m with FX-03 reflector Max covered area: 750 mq Protection against the inversion of polarity Digitally codified infrared beam Power Consumption: 18,6 ma in normal operation 34 ma with the alarm relay activated 34 ma with the turbulence relay activated 50 ma with both alarm and fault relay activated Maximum angular missallignment of the detector: +/- 0,2 Maximum angular missallignment of the reflector: +/- 0,2 Selection of the obscuration alarm threshold level with a 4 positions switch: position 1-70% position 2-60% position 3-50% position 4-40% Selection of the turbulence alarm threshold level with a 4 positions switch Alarm Relay activation delay: 10 s Fault Relay activation delay: 5 s Detector's recovery time with alarm memory dectivated: about 5 s Detector's recovery time with alarm memory activated: about 5 s (power supply off) Working temperature: C Red LED indication: alarm status Blue LED indication: compensation limit, interrupted beam, fault Alarm Relay: 1A/24 V dc Turbulence Relay: 1A/24 V dc - (RK90R) Fault/Maintenance Relay: 1A/24 V dc 0-5 V Analog Output for signal level measuring/ visualization Dimensions: 162 x 62 x 62 mm. Housing: autoextinguishing policarbonate box Relevant Standard: EN Certifications: EN54-12/CPD (0786-CPD-20803), VDS2504-VDS2344 (G209131) Protection Index: IP 50 (IEC ) Weight: 200 gr.

4 Optical Beam Smoke Detector RK100R - RK100RS TECHNICAL INFORMATION APPLICATIONS industrial buildings storehouses supermarkets shops libraries theaters cinemas conference halls control rooms hotels The RK100R it's a reflection Beam Smoke TECHNICAL FEATURES Detector. CERTIFIED a single detector can cover an area up to 1500 mq. EN54-12 installation is easy and quick Its operation is based on the relation between the internal electronics are controlled by a the smoke present in an environment, generated by the starting of a fire, and the infrared beam emitted microprocessor a special function automatically compensates the signal drift caused by the opacity on the optical parts generated by dust by the device and reflected by a special optical reflector. It is also able to detect the presence of vapour and fog. and dirt minimizing the maintenance needs the detector RK100R has 2 separated circuits for smoke detection: Oscuration and Turbulence A fundamental feature of this detector is the ability to detect the the detector RK100RS has only the circuit for smoke presence of both white smoke and black smoke even if they are detection: Oscuration RK100R - 3 relay outputs: Alarm, Turbulence, Fault little dense. RK100RS - 2 relay outputs: Alarm, Fault This detector has been specifically designed for industrial analog output that allows to remotely visualize the detector's applications where quality, reliability, precision and easyness of signal level using an optional led bar module maintenance is easy and not frequent use have primary importance. very low operational costs- cost effective Remote visualization is available using an optional module. simplified allignment with signal level led indication EN54-12 CPD and VDS certified

5 OPERATION TECHNICAL DATA The RK100R it's an Optical Beam Smoke Detector suited with 2 separated detection circuits based on the principles of Obscuration and Turbulence (RK100R). Oscuration The device has to be installed at one end of the area to be protected just under the level of the ceiling and the special reflector (FX) must be installed at the other end. When a fire begins, it produces smoke that rises up and intercepts the infrared beam of the detector. This causes an attenuation of the received signal that, if the threshold level is reached, will activate its alarm relay that can drive suitable alarm signalling devices. Turbulence Normally, during the starting phase of a fire, smoke clouds are generated and the thermal energy of the fire (heat) produces bubbles of hot air that rise up. When these clouds and bubbles intercept the beam emitted by the detector, they cause a perturbation in it because they modify the optical-physical caratheristics of the transmission medium of the beam. These variations are obviously time related. A suitable circuit has been designed to detect these variations and when they reach the preset amplitude and time duration levels, an alarm signal is generated. The advantage of using the turbulence detection circuit it's a quicker detection of the fire, because it is revealed in it's beginning. So RK90R, with this circuit, reveals dinamically both the smoke clouds by the starting of the fire and, in case the fire generates flames and so thermal energy, the perturbation phenomena produced by the combustion process. Optical Reflectors 4 types of optical reflectors can be used with RK90R: FX01 - FX02 - FX03 - FX07. The reflectors choice has to be done according to the optical path lenght (distance beween detector and reflector) and to aesthetic needs of the environment. FX - 09 is particularly suitable for application with short optical path and where good aesthetics are needed. Option BLP Laser Pointer - eliminates the need to use a lamp for optical alignment detectorreflector - the pointer is installed and collimated in the laboratory - the time of installation of the detector is drastically reduced - just point the laser beam on the reflector to have optics aligned. Model: RK100R Type: Reflection Optical Beam Smoke Detector Manufacturer: EDS srl - V. Cà Nova Zampieri S.G. Lupatoto - Verona - ITALY Power Supply: 12/24 Vdc Power Supply Range: Vdc Optical Path Lenght: m with FX-09 reflector m with FX-01 reflector m with FX-02 reflector m with FX-03 reflector Max covered area: 1500 mq Protection against the inversion of polarity Digitally codified infrared beam Power Consumption: 18,6 ma in normal operation 34 ma with the alarm relay activated 34 ma with the turbulence relay activated 50 ma with both alarm and fault relay activated Maximum angular missallignment of the detector: +/- 0,2 Maximum angular missallignment of the reflector: +/- 0,2 Selection of the obscuration alarm threshold level with a 4 positions switch: position 1-70% position 2-60% position 3-50% position 4-40% Selection of the turbulence alarm threshold level with a 4 positions switch Alarm Relay activation delay: 10 s Fault Relay activation delay: 5 s Detector's recovery time with alarm memory dectivated: about 5 s Detector's recovery time with alarm memory activated: about 5 s (power supply off) Working temperature: C Red LED indication: alarm status Blue LED indication: compensation limit, interrupted beam, fault Alarm Relay: 1A/24 V dc Turbulence Relay: 1A/24 V dc - (RK100R) Fault/Maintenance Relay: 1A/24 V dc 0-5 V Analog Output for signal level measuring/ visualization Dimensions: 247 x 146 x 114 mm. Housing: autoextinguishing policarbonate box Relevant Standard: EN Certifications: EN54-12/CPD (0786-CPD-20803), VDS2504-VDS2344 (G209131) Protection Index: IP 65 (IEC ) Weight: 900 gr.

6 Optical Beam Smoke Detectors RK100B-RK200B RK100BS -RK200BS TECHNICAL INFORMATION APPLICATIONS industrial buildings storehouses supermarkets shops libraries theaters cinemas conference halls control rooms hotels The RK100B and RK200B are Optical Beam CERTIFIED TECHNICAL FEATURES Smoke Detectors with separated Trasmitter (TX) EN54-12 a single detector (TX+RX) ac cover an area VDS CPD up to mq (EN54-14 standard) and Receiver (RX). The RK100B detector has a installation is easy and quick maximum optical path of 120m. The RK100B the internal electronics are controlled by a detector has a maximum optical path of 200m. microprocessor Their operation is based on the relation between the smoke present a special function automatically compensates the signal drift caused by the opacity on the optical parts generated by dust in an environment, generated by the starting of a fire, and the and dirt minimizing the maintenance needs infrared beam emitted by the transmitter towards the receiver. the detectors RK100B-RK200B have 2 separated circuits for It is also able to detect the presence of vapour and fog. A fundamental feature of this detectors is the ability to detect the presence of both white smoke and black smoke even if they are smoke detection: Oscuration and Turbulence the detectors RK100BS-RK200BS have only circuits for smoke detection: Oscuration RK100B-RK200B - 3 relay outputs: Alarm, Turbulence, Fault RK100BS-RK200BS - 2 relay outputs: Alarm, Fault little dense. analog output that allows to remotely visualize the detector's This detectors have been specifically designed for industrial signal level using an optional led bar module maintenance is easy and not frequent applications where quality, reliability, precision and easyness of very low operational costs - cost effective use have primary importance. simplified allignment with signal level led indication Remote visualization is available using an otional module EN54-12 CPD and VDS certified

7 OPERATION The RK100B and RK200B are Optical Beam Smoke Detectors suited with 2 separated detection circuits based on the principles of Obscuration and Turbulence (RK100B-RK200B). Oscuration The transmitter has to be installed at one end of the area to be protected just under the level of the ceiling and the receiver must be installed at the other end. When a fire begins, it produces smoke that rises up and intercepts the infrared beam of the detector. This causes an attenuation of the received signal that, if the threshold level is reached, will activate its alarm relay that can drive suitable alarm signalling devices. Turbulence Normally, during the starting phase of a fire, smoke clouds are generated and the thermal energy of the fire (heat) produces bubbles of hot air that rise up. When these clouds and bubbles intercept the beam emitted by the detector, they cause a perturbation in it because they modify the optical-physical caratheristics of the transmission medium of the beam. These variations are obviously time related. A suitable circuit has been designed to detect these variations and when they reach the preset amplitude and time duration levels, an alarm signal is generated. The advantage of using the turbulence detection circuit it's a quicker detection of the fire, because it is revealed in it's beginning. So RK90R, with this circuit, reveals dinamically both the smoke clouds by the starting of the fire and, in case the fire generates flames and so thermal energy, the perturbation phenomena produced by the combustion process. Option BLP Laser Pointer - eliminates the need to use a lamp for optical alignment detector-reflector - the pointer is installed and collimated in the laboratory - the time of installation of the detector is drastically reduced - just point the laser beam on the receiver RX. TECHNICAL DATA Models: RK100B-RK200B RK100BS-RK200BS Type: Barrier Optical Beam Smoke Detector Manufacturer: EDS srl - V. Cà Nova Zampieri S.G. Lupatoto - Verona - ITALY Power Supply: 12/24 Vdc Power Supply Range: Vdc Max Optical path: 120 m for RK100B 200 m for RK200B Max cover area.: sm (EN54-14 standard) Protection against the inversion of polarity Digitally codified infrared beam Power Consumption of TX: 9,5 ma Power Consumption of RX: 18,6 ma in normal operation 34 ma with the alarm relay activated 34 ma with the turbulence relay activated 50 ma with both alarm and fault relay activated Maximum angular missallignment of the detector: +/- 0,5 Selection of the obscuration alarm threshold level with a 4 positions switch: position 1-70% position 2-60% position 3-50% position 4-40% Selection of the turbulence alarm threshold level with a 4 positions switch Alarm Relay activation delay: 10 s Fault Relay activation delay: 5 s Detector's recovery time with alarm memory dectivated: about 5 s Detector's recovery time with alarm memory activated: about 5 s (power supply off) Working temperature: C Red LED indication: alarm status Blue LED indication: compensation limit, interrupted beam, fault Alarm Relay: 1A/24 V dc Turbulence Relay: 1A/24 V dc - (RK B) Fault/Maintenance Relay: 1A/24 V dc 0-5 V Analog Output for signal level measuring/ visualization Dimensions: 247 x 146 x 114 mm. Housing: autoextinguishing policarbonate box Relevant Standard: EN Certifications: EN54-12/CPD (0786-CPD-20803), VDS2504-VDS2344 (G209131) Protection Index: IP 65 (IEC ) Weight: 900 gr.

8 Laser Beam Pointer for Optical Beam SmokeDetectors BLP-90 BLP-100 TECHNICAL INFORMATIONS ACCESSORIES FOR EDS OPTICAL BEAM SMOKE DETECTORS they eliminate the need to use a lamp for the optical alignment of the detectors the laser pointers are already installed on the detector and optically collimated in the laboratory the procedure of optical alignment of the linear smoke detectors EDS with these pointers becomes extremely quick and easy CODES BLP-90...for RK90R BLP for RK100R-100B-200B drastic reduction of the detectors installation time The alignment procedure of the detector with its reflector (for reflection detectors RK90R and RK100R) or between TX and RX (for barrier detectors RK100B and RK200B), consists in adjusting the optical crew, of which the detectors are equipped, in so that the bright spot of the laser (red dot) falls at the center of the reflector or its opposite element RX. The technical information in this document have been carefully checked and can be considered reliable. In any case the EDS Company is not responsable for any eventual inaccuracy and reserves the right to make changes to any part of this document and/or to the products, in order to improve their quality, reliability or design. EDS - ELECTRONIC DETECTION SYSTEMS Via Ca' Nova Zampieri S.G. Lupatoto - VERONA - ITALY Tel: Fax: Web: eds@eds.eu

RK100B - RK200B RK100BS - RK200BS

RK100B - RK200B RK100BS - RK200BS END TO END (BARRIER) OPTICAL BEAM LINEAR SMOKE DETECTOR RK00B - RK00B RK00BS - RK00BS TECHNICAL MANUAL TECHNICAL INSTRUCTIONS FOR INSTALLATION, SETUP AND MAINTENANCE NOTE - the version -S detectors (RK00BS-RK00BS)

More information

FLV 40 UV Flame Detector

FLV 40 UV Flame Detector FLV 40 UV Flame Detector TECHNICAL INSTRUCTIONS FOR INSTALLATION, SETUP ANDMAINTENANCE EDS srl - V. Cà Nova Zampieri 6-37057 S.G.Lupatoto - Verona - Italy - tel +39045547529 - fax. +390458750065 - Mail:

More information

EDS - SPARK DETECTORS - GENERAL NOTES

EDS - SPARK DETECTORS - GENERAL NOTES 1 EDS - SPARK DETECTORS - GENERAL NOTES The spark detectors are electronic devices suitable for the detection of sparks in the pipes or transport ducts of conbustible material of different nature (sawdust,

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

Beam Detectors. The 6500 Series

Beam Detectors. The 6500 Series Beam Detectors The 6500 Series The world s finest manufacturing facility System Sensor s European products are researched, designed and manufactured at our 10,000m 2 state-ofthe-art facility in Trieste,

More information

Installation and Operation Manual

Installation and Operation Manual [Please read this installation & operation manual before install and use this Installation and Operation Manual Address: 8-701,Dongfangming Industry Zone, Dabao Road., Baoan, Shenzhen, China-518101 Page

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

Motorised Infrared Optical Beam Smoke Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide Motorised Infrared Optical Beam Smoke Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)

More information

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved. TX7130 Conventional Reflective Beam Detector Installation and Operation Manual Technology Copyright 2015, All right reserved. Product Safety To prevent severe injury and loss of life or property, read

More information

English. Series. Installation and Use Manual

English. Series. Installation and Use Manual English Series FOSTER Installation and Use Manual FOSTER Rev.13 03/2015 MITECH srl reserves the right to change the information in this document without warning. Index Anti-intrusion barrier 3 Main components

More information

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS CONTENTS mod. ERHSO712 (Transmitter-Receiver version) Basic characteristics.......................................... 3 Product characteristics........................................ 3 Working Principle............................................

More information

Fireray 2000 Linear Smoke Detector

Fireray 2000 Linear Smoke Detector Fire Alarm Systems Fireray 2000 Linear Smoke Detector Fireray 2000 Linear Smoke Detector Extended monitoring area Increased security against false alarms with gain control Potential-free, self-holding

More information

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Why choose Fireray? Why use a Beam Smoke Detector? Product Range. Range Brochure Why use a? Beam smoke detectors are the wide area smoke detection technology of choice, offering both excellent detection and value for money. With a high area of coverage per unit (as high

More information

INDEX. Installation recommendation

INDEX. Installation recommendation Technical manual INDEX 1 MAIN COMPONENTS Pag. 3 2 ASSEMBLING THE CABLEPIT Pag. 4 CABLE PIT POSITIONING Pag. 6 3 BASE INSTALLATION ON CABLE PIT Pag. 8 4 INSTALLATION EXAMPLES Pag. 9 5 CONFIGURATION OF THE

More information

this is by far the best beam money can buy

this is by far the best beam money can buy It s the ultimate optical beam smoke detector available today, it will self align when commissioning and continually re-align itself against building movement in normal service. Ease of use and unprecedented

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Apollo Intelligent Auto Aligning Beam Detector. User Guide Apollo Intelligent Auto Aligning Beam Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)

More information

Motorised Infrared Optical Beam Smoke Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide Motorised Infrared Optical Beam Smoke Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd. TITLE SLIDE FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR Doc. No: 32-0009-01 OPTICAL BEAM SMOKE DETECTORS This training material provides information to assist the Fire System Designer and Installer in

More information

Reflective Optical Beam Smoke Detector User Guide

Reflective Optical Beam Smoke Detector User Guide Reflective Optical Beam Smoke Detector User Guide 1. Installation IMPORTANT NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the system initiating

More information

Line Smoke Detector LRMX

Line Smoke Detector LRMX Line Smoke Detector LRMX Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during

More information

CONFIGURATION OF THE OPTICALS

CONFIGURATION OF THE OPTICALS Technical manual INDEX 1 MAIN COMPONENT LIST Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION SAMPLES Pag. 6 4 CONFIGURATION OF THE OPTICALS Pag. 7 OPTICAL TX Pag. 7 OPTICAL

More information

ALK-V PHOTOELECTRIC SMOKE SENSOR

ALK-V PHOTOELECTRIC SMOKE SENSOR ALK-V PHOTOELECTRIC SMOKE SENSOR APPLICATION The HOCHIKI America ALK-V Photoelectric Smoke Sensor is particularly suited to detecting optically dense smoke typical of fires involving materials such as

More information

FLV45 FLV45A FLV45A-AL

FLV45 FLV45A FLV45A-AL Flame Detector IR + UV FLV45 FLV45A FLV45A-AL Technical Manual EDS - V. Ca' Nova Zampieri 6-37057 S. G. Lupatoto - VERONA - Tel. 0039045547529 - Fax. 00390458750065 - Email: eds@eds.eu - Web: www.eds.eu

More information

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity Scanning HOT METAL DETECTOR Rota-Sonde DC4000-L Two sensitivity ranges : 400 C and 230 C Laser pointer for easy alignment Remote control of the sensitivity Self-monitoring ISO 9001 Applications Benefits

More information

Fact File 66. Guide to Beam Smoke Detectors

Fact File 66. Guide to Beam Smoke Detectors Fact File 66 Guide to Beam Smoke Detectors Guide to Beam Smoke Detectors INTRODUCTION... 3 TERMINOLOGY... 4 PURPOSE OF BEAM DETECTORS... 5 PROS AND CONS OF BEAM DETECTORS... 6 FUNDAMENTAL PRINCIPLES OF

More information

TECHNICAL SPECIFICATIONS BUTTONS

TECHNICAL SPECIFICATIONS BUTTONS Maxlogic beam type smoke detector consists of 2 parts as a receiver and transmitter. Should be mounted as facing each other between the distance of 5-100 m. The detector works on the principle of light

More information

Installation And commissioning manual. Series S Double Beam 1/16

Installation And commissioning manual. Series S Double Beam 1/16 Installation And commissioning manual Series S Double Beam 1/16 2/16 Index Main components list Pag. 4 Installation reccomendations Pag. 5 Mounting the bracket Pag. 6 Installation example Pag. 7 Positioning

More information

Open-area Smoke Imaging Detector. Engineering Specification

Open-area Smoke Imaging Detector. Engineering Specification Open-area Smoke Imaging Detector 15273_02 October 2011 Table of Contents 1. Scope... 3 2. System Information... 3 2.1 General... 3 2.2 Approvals... 3 2.3 Codes, Standards or Regulations... 3 2.4 System

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) www.xtralis.com/osid Large, open spaces warehouses, airports, train stations, stadiums and shopping malls pose unique challenges to reliable fire detection due

More information

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS INFRARED PERIMETRAL BARRIER DOUBLE BEAMS Index 1 MAIN COMPONENT LIST Pag. 3 2 INSTALLATION TIPS Pag. 5 3 INSTALLATION Pag. 6 WALL MOUNTING Pag. 6 POLE MOUNTING Pag. 6 4 CONNECTIONS AND DESCTIPRIONS Pag.

More information

C-9105R Conventional Reflective Beam Detector Installation and Operation Manual. (Issue 2.01, February 2006)

C-9105R Conventional Reflective Beam Detector Installation and Operation Manual. (Issue 2.01, February 2006) (Issue 2.01, February 2006) CONTENTS I General... 1 II Features... 1 III Technical Specifications... 1 IV Structure and Operation Principle... 2 V Mounting and Wiring... 4 1. Ambient Conditions for Installation...

More information

INDEX. Installation recommendation

INDEX. Installation recommendation Technical manual INDEX 1 MAIN COMPONENTS Pag. 3 2 ASSEMBLING THE CABLEPIT Pag. 4 CABLE PIT POSITIONING Pag. 6 3 BASE INSTALLATION ON CABLEPIT Pag. 8 4 INSTALLATION EXAMPLES Pag. 9 5 WIRING Pag. 10 6 CONFIGURATION

More information

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors D96/D97 EN Installation Instructions Long-Range Beam Smoke Detectors D96/D97 Installation Instructions.0 Description FCC Compliance Notice This equipment was tested and complies with the limits for a Class

More information

Laser Collimated Beam Sensor

Laser Collimated Beam Sensor SERIES Laser Collimated Beam Sensor Class 1 Laser Beam Sensor Safe for Your Eyes Marked Conforming to EMC Directive (Excluding LA-C1) Safe Laser Beam This laser collimated beam sensor conforms to the Class

More information

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS CONTENTS I Overview...1 II Features...1 III Technical Specifications...2 IV Structure and Operation Principle...4 V Mounting and Wiring...6 1. Ambient Conditions for Installation...6 2. Mounting Height

More information

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8 Characteristics photo-electric sensor - XUM - multi - Sn 0..10m - 12..24VDC - M8 Main Range of product Series name Electronic sensor type Sensor name Sensor design Detection system Material Type of output

More information

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS Steve Glander: Senior Sales Engineer All Weather, Inc. 1165 National Dr. Sacramento, CA

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) OSID Smoke Detection Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual

More information

Key Features. General Description

Key Features. General Description Key Features SIL2 rated, for certified dependability (fail-safe detection) Special coating for electronics protection in harsh environments Dedicated temperature range, for maximum detection accuracy Individual

More information

Laser Technology Smoke Detector

Laser Technology Smoke Detector C1 Application Guide Laser Technology Smoke Detector LASER. SMOKE DETECTORS EARLIEST WARNING DUCT SMOKE APPLICATIONS DETECTOR Laser Technology Smoke Detector Contents Section I Laser. Earliest Warning

More information

Analogue Detectors. Series 200 plus

Analogue Detectors. Series 200 plus Analogue Detectors Series 200 plus The world s finest manufacturing facility System Sensor s European products are researched, designed and manufactured at our 10,000m 2 state-ofthe-art facility in Trieste,

More information

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag. BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL Manuale istruzioni BST-100 Pag. 1 1 - Product Discription The BST-100 is an active indoor & outdoor infrared

More information

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual SANDOR QUAD/ESA Double beam Installation And commissioning manual 1 POLITEC s.r.l. Index Main components list Pag. 3 Installation reccomendations Pag. 4 Mounting the bracket Pag. 5 Installation example

More information

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12 Characteristics photo-electric sensor - XUX - multi - Sn 0..40m - 12..24VDC - M12 Complementary Enclosure material Lens material Maximum sensing distance Output type Add on output Status LED [Us] rated

More information

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

IRtech. E instruments. IRtech Radiamatic IR20 LS series.  Infrared Technology E instruments IRtech Temperature range up to 2200 C Optical resolution up to 300:1 Close focus 0,5mm 8-14µm, 1.6µm, 1µm, 2.3µm, 3.9µm, 4.2µm, 4.6µm, 5.1µm and 7.9µm Spectral response Dual laser true target

More information

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd. TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR Doc. No: 32-0008-01 OPTICAL BEAM SMOKE DETECTORS This training material provides information to assist the Fire System Designer and Installer in achieving

More information

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector A P P L I C A T I O N S G U I D E Single-Ended Reflected Beam Smoke Detector A P P L I C A T I O N S G U I D E Single-Ended Reflected Beam Smoke Detector Contents Section 1 Principles of Operation............................................................................

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

OH110, OP110, HI110 Automatic fire detectors

OH110, OP110, HI110 Automatic fire detectors OH110, OP110, HI110 Automatic fire detectors For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 color LED indication Drift compensation

More information

CATALOGUE LASER POINTERS

CATALOGUE LASER POINTERS CATALOGUE LASER POINTERS SM.PROX SRL Via della Beverara 13/A - 40131 Bologna - Italy Tel. +39 051 6350755 - Fax +39 051 6353462 Edition October 2014 With the publication of this catalogue all former editions

More information

Intelligent Addressable Fire Alarm System

Intelligent Addressable Fire Alarm System Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR GENERAL The model 6500R is a conventional long range projected beam smoke detector designed to provide

More information

ASA linear smoke detector

ASA linear smoke detector Sinteso / Cerberus PRO ASA linear smoke detector FDL241-9 Linear smoke detector, used addressed or collectively, ASAtechnology TM Reliable smoke detection in large spaces (indoor application) Detection

More information

Explosion-proof ATEX Spark Detector SCL-01

Explosion-proof ATEX Spark Detector SCL-01 Explosion-proof ATEX Spark Detector SCL-01 TECHNICAL MANUAL EDS srl - V. Ca' Nova Zampieri 6-37057 S. G. Lupatoto - VERONA - Tel. +39045547529 - Fax +390458750065 Email: eds@eds.eu - Web: www.eds.eu 1

More information

MODEL 6200 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR

MODEL 6200 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR MODEL 600 OPTICAL BEAM SMOKE DETECTOR ADDRESS CODING SW0 ON 4 8 4 8 UNITS TENS DIGIT REQUIRED Switch 8 Switch 4 Switch Switch 0 off off off off off off off on off off on off 3 off off on on 4 off on off

More information

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The

More information

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide KEY FEATURES Flameproof Receiver and Transmitter Standard Fireray Controller Unit High Coverage - up to 1500 2 m per system Low Cost Beam

More information

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. (Issue 2.03 February 2006)

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. (Issue 2.03 February 2006) (Issue 2.03 February 2006) CONTENTS I General... 1 II Features... 1 III Technical Specifications... 1 IV Structure and Operation Principle... 2 V Mounting and Wiring... 4 1. Ambient Conditions for Installation...

More information

DUAL OPTIC. Installation manual

DUAL OPTIC. Installation manual DUAL OPTIC Installation manual INDEX 1 COMPONENTS Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION EXAMPLES Pag. 6 4 CABLES AND CABLING Pag. 7 CONNECTION AND HEATING SETTING

More information

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours Dräger Polytron Pulsar 2 Detection of flammable gases and vapours The Dräger Polytron Pulsar 2 is the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard

More information

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE Exercise 1 Introduction to Sensors EXERCISE OBJECTIVE When you have completed this exercise, you will be introduced to photoelectric, capacitive and inductive sensors; You will also be introduced to the

More information

Active Infrared Multi Beam Sensors

Active Infrared Multi Beam Sensors Active Infrared Multi Beam Sensors D Series TECHNICAL MANUAL INDEX GENERAL SAFETY RECOMMENDATIONS 3 CONFORMITY 4 WARRANTY 4 INTRODUCTION 5 FEATURES 5 OPERATIONAL RANGE 6 SETUP TRANSMITTER (TX) 6 SETUP

More information

D296/D297. Application Guide. Projected Beam Smoke Detectors

D296/D297. Application Guide. Projected Beam Smoke Detectors D96/D97 EN Application Guide Projected Beam Smoke Detectors D96/D97 Application Guide.0 Introduction Trademarks The National Fire Alarm Code is a registered trademark of the National Fire Alarm Association,

More information

End To End Optical Beam Smoke Detector. Additional Information

End To End Optical Beam Smoke Detector. Additional Information End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important

More information

Active Infrared Multi Beam Sensors. R Series

Active Infrared Multi Beam Sensors. R Series Active Infrared Multi Beam Sensors R Series TECHNICAL MANUAL INDEX GENERAL SAFETY RECOMMENDATIONS 3 CONFORMITY 4 WARRANTY 4 INTRODUCTION 5 FEATURES 5 OPERATIONAL RANGE 6 SETUP TRANSMITTER (TX) 6 SETUP

More information

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm. E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration

More information

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION Active infrared The recently updated range of Prastel active infra-red offers many solutions: WALL-FLUSH INTERNAL OR EXTERNAL PROTETION For short range perimeter protection (doors, windows, balconies)

More information

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS INFRARED PERIMETRAL BARRIER DOUBLE BEAMS 1 MAIN COMPONENT LIST Pag. 3 2 SUGGEST FOR INSTALLATION Pag. 5 3 INSTALLATION Pag. 6 WALL MOUNTING Pag. 6 POLE MOUNTING Pag. 6 4 CONNECTIONS AND DESCTIPRIONS Pag.

More information

EN 54/12 EN /96/CE. ECO con snodo - with articulated bracket - mit Kugelge- ECO con snodo - with articulated bracket - mit Kugelgelenk

EN 54/12 EN /96/CE. ECO con snodo - with articulated bracket - mit Kugelge- ECO con snodo - with articulated bracket - mit Kugelgelenk Riferimenti normativi - Reference regulations - Vorschriften normen ECO con snodo - with articulated bracket - mit Kugelge- ECO con snodo - with articulated bracket - mit Kugelgelenk Costruito in conformità

More information

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds Fireray 2000 pplication and FETURES Installation Guide Range 10-100 metres 12V to 24V dc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or automatic reset

More information

INDEX. Installation recommendation

INDEX. Installation recommendation Technical manual INDEX 1 MAIN COMPONENTS Pag. 3 2 MOUNTING SAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION SAMPLES Pag. 6 4 WIRING Pag. 7 5 CONFIGURATION OF THE OPTICALS Pag. 8 OPTICAL TX Pag.

More information

Beam detector DBD-DL40 KBD-DL80 KBD-DL100

Beam detector DBD-DL40 KBD-DL80 KBD-DL100 DBD-DL40 Beam detector Beam detector for distances over 5 metres and up to 40 meters, expandable up to 80 or 100 meters with extension kits. Separated head detector and controller for easy access to programming.

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11

More information

850 Series Fire Detectors - Generation 6

850 Series Fire Detectors - Generation 6 DATASHEET 850 Series Fire Detectors - Generation 6 Features: Choice of heat, optical, optical and heat multi-sensor or 3oTec triple multi-sensor Any Pantone colour available with CPD approval Advanced

More information

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S / Introduction /3 photoelectric sensors /5 ultrasonic sensors /6 4 sensor module for ET 00S /6 8 sensor module for ET 00M/S7-300 Introduction Configuration/parameterization Uniform configuration tools

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR INSTALLATION AND MAINTENANCE INSTRUCTIONS 00R AND 00RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR GENERAL The model 00R is a conventional long range projected beam smoke detector designed to provide

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660 Selectivity Adjustable by Means of - High Pass Frequency Filter - Gain - Threshold Different Adjustments for Different Conditions (e.g. According Fuel or Combustion Technology) Possible, to be Activated

More information

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System SAFETY MANUAL Open Path Hydrocarbon Gas Monitoring System The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible Measurement & Analytics Measurement made easy LLT100, LM80, and LM200 Lasers for level: Now everything is possible Expertise in technology from more than a century of experience To operate any process

More information

Cerberus FIT conventional system

Cerberus FIT conventional system Cerberus FIT conventional system Combining intelligent signal processing and easy installation for reliable fire detection and alarming www.siemens.com/cerberus-fit Reliable, intelligent and cost-efficient

More information

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS

More information

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS 2 AERECO VMX VMX, A UNIQUE SOLUTION TO RECONCILE AIR QUALITY AND ENERGY SAVINGS IN NON RESIDENTIAL BUILDINGS AERECO VMX 3 In developed countries,

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

850 and 830 Series. Fire Detectors - Generation 6

850 and 830 Series. Fire Detectors - Generation 6 The 850 and 830 series fire detectors are designed to be both adaptable and flexible which means they can be used in most premises to protect against a wide range of potential fire risks. They use sophisticated

More information

Chapter 17, Initiating Devices

Chapter 17, Initiating Devices Chapter 17, Initiating Devices Summary. Chapter 17 was Chapter 5 in NFPA 72-2007. The term authority having jurisdiction is replaced in some sections by the term other governing laws, codes, or standards.

More information

Synchronous Detector

Synchronous Detector Synchronous Detector Synchronous Detector As an addition to Global Laser s Detector Range, and designed to compliment the modulatable range of laser modules, the Synchronous Detector provides a 5V switched

More information

830 Series. Fire Detectors - Generation 6

830 Series. Fire Detectors - Generation 6 The 830 series fire detectors are designed to be both adaptable and flexible which means they can be used in most premises to protect against a wide range of potential fire risks. They use sophisticated

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global

More information

CAUTIONS ON INSTALLATION

CAUTIONS ON INSTALLATION 2 CAUTIONS ON INSTALLATION 1) DO'S AND DON'T'S 2) Protection distance Do not install the unit at places where it may be interrupted by obstacles such as trees. Avoid strong light from the sun, automobile

More information

Range brochure. Beam detection. others look up to.

Range brochure. Beam detection. others look up to. Range brochure Beam detection others look up to FFE, the independent fire detection company, is raising the bar in beam detection with the new Fireray range. The new Fireray range is a cleverly designed

More information

Laser Distance Sensor Type M Analog-Output

Laser Distance Sensor Type M Analog-Output Laser Distance Sensor Type M Analog-Output Operating Manual Version 2.3, May 2009 ELAG Elektronik AG l Stegackerstrasse 14 l CH-8409 Winterthur Contents 1. Safety 1.1 Laser safety 1.2 Electrical safety

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR GENERAL The model 6500 is an addressable long range projected beam smoke detector designed to provide

More information

SecuriBeam Optical Beam Fire Detectors

SecuriBeam Optical Beam Fire Detectors SecuriBeam Optical Beam Fire Detectors Product Catalogue 2015 Content 1. Beam Detector BSD... 5 1.1. SecuriBeam BSD 535... 5 1.2. Accessories for BSD... 6 2. Beam Detector ILIA... 8 2.1. SecuriBeam ILIA...

More information

CODESEC FIRE ALARM SYSTEMS. security technologies

CODESEC FIRE ALARM SYSTEMS. security technologies CODESEC FIRE ALARM SYSTEMS security technologies AA402 ADRESSABLE FIRE ALARM CONTROL PANEL AA402 Electronic Addressable Intelligent Fire Alarm Control Panel Onboard one loop, 250 nodes per loop, Metal

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) Large, open spaces warehouses, airports, train stations, stadiums and shopping malls pose unique challenges to reliable fire detection due to their environmental

More information