/9308 External Battery Chargers Installation Instructions
|
|
- Russell Wilson
- 6 years ago
- Views:
Transcription
1 /9308 External Battery Chargers Installation Instructions Introduction This publication describes the installation procedure for an External Battery Charger used with the 4100U or 4100ES System. IMPORTANT: Verify FACP System Programmer, Executive, and Slave Software compatibility when installing, or replacing system components. Refer to the Technical Support Information and Downloads website for compatibility information. In this Publication This publication discusses the following topics: Topic See Page # Cautions and Warnings 2 General Description 3 Configuring the External Battery Charger 6 Locating and Wiring the External Battery Charger SimplexGrinnell LP. All rights reserved. Specifications and other information shown were current as of publication and are subject to change without notice. Simplex and the Simplex logo are trademarks of Tyco International Ltd. and its affiliates and are used under license Rev. D
2 Cautions and Warnings Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in this installation manual. These instructions must be followed to avoid damage to this product and associated equipment. Product operation and reliability depend upon proper installation. DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED- Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify an authorized Simplex product supplier. ELECTRICAL HAZARD - Disconnect electrical field power when making any internal adjustments or repairs. All repairs should be performed by a representative or authorized agent of your local Simplex product supplier. EYE SAFETY HAZARD - Under certain fiber optic application conditions, the optical output of this device may exceed eye safety limits. Do not use magnification (such as a microscope or other focusing equipment) when viewing the output of this device. STATIC HAZARD - Static electricity can damage components. Handle as follows: Ground yourself before opening or installing components. Prior to installation, keep components wrapped in anti-static material at all times. FCC RULES AND REGULATIONS PART 15 - This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. SYSTEM REACCEPTANCE TEST AFTER SOFTWARE CHANGES - To ensure proper system operation, this product must be tested in accordance with NFPA , Chapter 7 after any programming operation or change in site-specific software. Reacceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known to be affected by a change must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. 2
3 General Description Introduction The external battery charger (XBC) consists of the battery charger PC board bracket assembly and the external battery cabinet. The external battery charger (XBC) is a communicating slave in a 4100U/4100ES System. A micro controller monitors all input and output functions on the charger and is capable of reporting all board statuses to the system CPU via a 4100-style communications channel. The XBC monitors and reports the following statuses: Battery charger status Battery status Positive earth fault Negative earth fault AC fail Both the battery cabinet and charger are shown in Figure 1. Battery Cabinet Bracket Assembly Batteries (shipped separately) Battery Charger PC Board Figure 1. Battery Cabinet and External Charger Continued on next page 3
4 General Description, Continued Charging Batteries The XBC can re-charge 55Ah 110Ah batteries per UL 864 and S527 requirements. When completely discharged, the batteries will demand a high current. As the battery charges, the rate of charge will decrease. The table below shows specific voltage and current information for both the supply and output of the battery charger. Table 1. System Voltage Ratings Voltage Range, Amps Supply Current At 120VAC, 4A Max. At 220/230/240VAC, 2A Max. Output Float Voltage *27.4V DC 20 High Voltage Output up to 7A (charger voltage determined by battery charge state) *temperature compensated at 24mV/ C (-5 C 50 C) **no temperature compensation Note: If the AC line drops below 85% of nominal (brownout or AC fail), the XBC will no longer charge the batteries. It will continue to operate and communicate to the system CPU, however. The XBC is a temperature compensated battery charger. It has no field adjustment. The charger voltage is higher when the temperature in the cabinet is low and lower when the temperature in the cabinet is high. A warmer environment than that noted in the table above will result in a lower output float voltage (see Table 1). The High Voltage Output shown above relates to the battery charger s dual rate ability. The high voltage output kicks in when the batteries are discharged. This allows battery capacity to be restored more quickly. When the batteries become close to full, the current will drop and the charger will switch back to the float voltage. Continued on next page 4
5 General Description, Continued Indicators The charger controller board contains three LED indicators for signaling various troubles with the operation of the system. They are used to indicate communications status, power supply status, and AC power status respectively. The tables below explain the trouble conditions of each LED. Table 2. LED 1 COMMS Status LED On Yellow Indication Lost communication with CPU or OFFLINE (if SW1 is set that way) Table 3. LED 2 Power Supply Status LED Off Single Blink Double Blink Triple Blink Quadruple Blink Indication Normal POS. Earth NEG. Earth Battery Trouble Charger Trouble Table 4. LED 3 AC Power LED On Green Indication Indicates charger running from AC Mains Environmental Requirements Normal Operating Temperature (Ambient Conditions Outside the Cabinet): -5 C to 50 C Humidity: normal operation under non-condensing humidity conditions up to 93% (ULC) relative 38 C (FM spec). 5
6 Configuring the External Battery Charger Introduction The External Battery Charger (XBC) is configured as part of a 4100 system in two steps. It must be programmed as part of the system. Use the PC-based 4100U or 4100ES Programmer to add the XBC to the system configuration. This will assign a system address used when communicating with the XBC. Refer to the ES Panel Programmer s Manual ( ) for instructions on adding the XBC to the system software configuration. Adding the XBC is similar to adding any other communicating slave to the system. The physical configuration of the board must be set. This includes setting the card address and positioning the hardware jumpers on the card. This section explains how to configure the battery charger and includes an illustration referring to the different components on the battery charger controller card. Address Switch LEDs 4100 Communications Connections Jumper R49 (Remove for S527) Battery Connector Jumper P3 Bridge Rectifier Connection Figure 2. External Battery Charger Controller Card Continued on next page 6
7 Configuring the External Battery Charger, Continued Jumpers The External Battery Charger has two options that are jumper selectable: the Earth Fault Monitor Jumper and the Depleted Battery Cutout Jumper. Their functions are explained below. Earth Monitor The XBC can be configured to monitor for earth faults. When the XBC is not located with an SPS or RPS, it should be configured to monitor for earth faults. Set jumper P3 at positions 1 and 2 to enable the monitoring of earth faults Set jumper P3 at positions 2 and 3 to disable the monitoring of earth faults When earth monitor is enabled, the XBC will detect earth faults on equipment that is connected to the same OV as the XBC. When RUI communications are used, OV points between cabinets are isolated. In those cases, a battery charger, SPS or RPS at a remote location is configured to monitor for earth faults for modules at that location. Depleted Battery Cutout Some jurisdictions require system cutout when a depleted battery condition is detected and AC has failed. You can set your system up to remove power from the XBC when the AC has failed and the batteries are depleted. Note: This is different than inhibiting alarms that occur after the batteries are already depleted. This operation shuts the system off. To activate this feature, Low Battery Cutout option must be selected in the Programmer. Refer to Appendix C in manual Also, a specific jumper must be removed from each power module in the system to activate depleted battery cutout operation. The XBC has one such jumper. If depleted battery cutout is desired, remove jumper R49. The jumper is labeled remove for S527 as this operation is specified in S527, the Canadian standard for fire alarms. This removes power from the XBC when AC fails and batteries are depleted. Note: Systems with this jumper removed will not power-up from battery power. Continued on next page 7
8 Configuring the External Battery Charger, Continued Address Switch The card address assigned to the XBC in the Programmer must also be set physically using the Address Switch located on the XBC s printed circuit board. The switch is 8 positions, with 7 positions used to set the address and 1 used to set the card either on or off line. SW8 SW2 are used to set card addresses. SW8 is the least significant bit (LSB). SW2 is the most significant bit (MSB). Each switch has a different weight. The sum of the weights of the switches turned OFF is the address setting. Valid addresses are in the range of 1 to 119. Two cards cannot occupy the same address. Table 5. Switch Weights Switch SW8 SW7 SW6 SW5 SW4 SW3 SW2 Weight Add 1 to card address if OFF Add 2 to card address if OFF Add 4 to card address if OFF Add 8 to card address if OFF Add 16 to card address if OFF Add 32 to card address if OFF Add 64 to card address if OFF The card is set either on or off-line with SW1. SW1 in the on position sets the card on-line. If SW1 is off, the card is off-line and will not communicate to the system CPU. LED 1 (yellow) on indicates that the card is off-line or when communications are otherwise inhibited. 8
9 Locating and Wiring the External Battery Charger Guidelines The external battery charger must be within 20 feet of the Fire Alarm Panel to which it supplies battery backup. All wiring to the external battery charger from the Fire Alarm Panel must be in conduit. All power and comm. wiring is in compliance with the requirements specified in NFPA 70, Article (1), Exception No.2 (b) (1). Connect AC Power AC power connects to the XBC at an off-board terminal block. There are two versions of the XBC: the 120V/60Hz and the 220/230/240V 50/60Hz model. For the 120V version, three connections are made: 1. Connect the HOT wire to the terminal marked 120V. 2. Connect the NEUTRAL wire to the terminal marked NEU. 3. Connect the safety ground to the ground stud marked with the EARTH symbol. For the 220/230/240V version, the same three connections are made only there are three different choices for input voltage. Therefore, the HOT wire should be connected to the appropriate terminal for the operating voltage being used. Connect the Battery The XBC connects to the batteries through a battery block. A two-conductor harness from the battery block snaps into a keyed connector on the XBC circuit board. The RED wire is +24V and the BLACK wire is OV. The harness does not carry the alarm load. It carries the current to the batteries only, which is about 7A maximum. The battery block can accept very large wire (up to 2AWG) in order to minimize the voltage drop to the equipment. When choosing the wire gauge to be used, consideration must be given to the details of each application. A system with a high worst-case load requires careful planning of the distance from the batteries to the system, wire gauge choice, and worst-case battery voltage. It is always best to use the largest gauge wire possible and to keep the distance to a minimum. Using 12 AWG wire results in a voltage drop of about 4mV/Ampere/foot. The drop is quite significant (see example). Example: Wire gauge = 12 AWG System with 3 Power Supplies = potential load of 27A Battery Cabinet distance from System = 20ft. Therefore, Voltage Drop =.004V * 27A * 20ft. = 2.16V If the battery discharge curves with an end voltage of 21V were used, the voltage to the system would be too low to provide the required notification. The system must be planned to avoid situations such as those described in the example. Generally, locate the battery cabinet as close to the FACP cabinet as possible and use as large a wire gauge as possible. Note: Another way to reduce voltage drop is to use multiple cabinets when current demand is high. Running a pair of wires to each cabinet reduces the overall voltage drop since each pair of wires carries a lower current. Continued on next page 9
10 Locating and Wiring the External Battery Charger, Continued 4100 Communications The communications (comms) harness, , is connected from a close-nippled 4100U/4100ES cabinet. The harness is constructed with type FPL cable to allow routing with the other connections to the XBC (refer to NFPA 70, Article (1), exception no. 2 (b) (1)). The harness is keyed for easy connection and plugs into connector P1 on the XBC. The other end gets connected to any of the four-position connectors on the PDI or CPU motherboard in the host system. This harness is long enough to allow for the maximum distance of 20 feet between the Fire Alarm Panel and the External Battery Charger. Connect the Bridge Rectifier Use harness number to connect H1 and H2 to the bridge rectifier. H1 +Bridge Rectifier (red wire) H2 -Bridge Rectifier (black wire) Rev. D
Panel Remote Annunciators Installation Instructions
Panel Remote Annunciators Installation Instructions Introduction This publication describes the installation procedures for the following PIDs: 4100-9607 Remote Annunciator w/ Flexible User Interface Domestic
More information/ XPS Interconnection Diagrams
4100-5153/4100-5154 XPS Interconnection Diagrams Introduction This publication provides interconnection diagrams for 4100-5153 (120 VAC) and 4100-5154 (220/240 VAC) 13 A Expansion Power Supplies (XPS).
More information4100U City and Relay Cards Installation Instructions
4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting
More informationNetwork Display Unit Installation Instructions
Network Display Unit Installation Instructions Introduction This publication describes the installation procedures for the optional Network Display Units (NDUs). This product is compatible with both the
More informationClass A and Expansion NAC Modules Installation Instructions
Class A and Expansion NAC Modules Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-1245 Flex Amplifier Expansion NAC (XNAC) 4100-1246
More information/5121/5122 TrueAlert Power Supply Installation Instructions
4100-5120/5121/5122 TrueAlert Power Supply Installation Instructions Introduction This publication provides an overview of the features, specifications, and capabilities of the TrueAlert power supplies
More informationAU MX Digital Loop Card Installation Instructions
4100-6077AU MX Digital Loop Card Installation Instructions Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS - Follow the instructions in this installation manual. These instructions must be followed
More informationAddressable IDNet Isolator Installation Instructions
4090-9116 Addressable IDNet Isolator Installation Instructions Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS - Follow the instructions in this installation manual. These instructions must be followed
More informationPanel Message Memory Expansion Cards Installation Instructions
Panel Message Memory Expansion Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-1241 Audio Message Memory Expansion Card (4 Megabytes
More information4009 Fiber Optic Link Option Installation Instructions
4009 Fiber Optic Link Option Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton
More informationCautions and Warnings. Introduction 4009 NAC POWER EXTENDER
Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately
More informationTrueAlert Addressable Notification
UL, ULC Approved* TrueAlert Addressable Notification 4009 IDNAC Repeater; Power and Distance Extender Features IDNAC Repeaters provide enhanced power delivery to TrueAlert/ TrueAlert ES addressable notification
More informationLifeAlarm Fire Alarm Controls
UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity
More informationBooster Power Supply Manual
Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation
More informationDoc. No Part No Rev. U * T*
Doc. No. 430545 Part No. 579-357 Rev. U *0579357T* Blank Page- Back of Front Cover Copyrights and Trademarks 2005-2018 Johnson Controls. All rights reserved. Specifications and other information shown
More information4010 Fire Alarm Parts List
4010 Fire Alarm Parts List Introduction This publication lists the service parts for the 4010 Fire Alarm Control Panel (FACP). Some of the base parts are shown in Figure 1. 478-332 120VAC or 478-333 220/240VAC
More informationSP-1000X. Panic Device Power Controller Installation Guide. Rev
TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp
More informationTrueAlert Addressable Notification Appliances
Fire Control ** IS NORMAL ** :0:pm Mon 9-Feb-9 SY S TE M AC SUPERVISORY TROUB LE SILENCED SUPV TROUBLE SILENCE RESET CONTROL DISC ON NEC T POW ER + V ZONE P WR + 0V ZONE P WR - +IDNE T IDC + - IDNE T IDC
More informationInstallation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev
Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.
More informationRAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description The TYCO RAPID RESPONSE Model RCP-1 Residential
More informationPS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01
PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Warnings and Notices WARNING - To reduce the risk of fire or electric shock, do not expose this product
More informationRAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) SECTIONS General Description.... 1 Warnings.... 2 Technical
More informationModels NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117
Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring
More informationFCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply
One Fire-Lite Place Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE Field Charger/Power
More informationSpecification/ Data Sheet
Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)
More informationOperator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B
Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES 579-685 Rev. B ii iii Cautions and Warnings Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in this installation
More informationSC-6 Six Supervised Control Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS SC-6 Six Supervised Control Module SPECIFICATIONS Normal Operating Voltage: Stand-By Current: Alarm Current: Temperature Range: Humidity: Dimensions: Accessories:
More informationInstruction Manual. CMP-12/24 Fire Alarm Control Panel. 12 Clintonville Road, Northford, CT DOCUMENT /11/96 REV: D1
12 Clintonville Road, Northford, CT 06472 Instruction Manual CMP-12/24 Fire Alarm Control Panel DOCUMENT 15819 3/11/96 REV: D1 P/N 15819:D1 ECN 96-047 Installation Precautions - Adherence to the following
More informationAPS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES
APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED
More information4100ES Fire Alarm System
FIRE ALARM 4100ES Fire Alarm System Installation Guide 574-848 Rev. AD Cautions, Warnings, and Regulatory Information Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in
More informationCZ-6A Six Zone Interface Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS CZ-6A Six Zone Interface Module 658 Kitimat Rd. Unit #6 Mississauga, Ontario L5N T5-800-SENSOR, FAX: 905-8-077 www.systemsensor.ca SPECIFICATIONS Normal Operating
More informationGENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING
GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,
More informationAC/DC Power Supply and Battery Charger Installation and Maintenance
AC/DC Power Supply and Battery Charger Installation and Maintenance 61175043L3-5A Issue 1, January 2004 CLEI Code: SIMPAADA_ CLEI Code: SIMPAAGA_ CONTENTS 1. GENERAL... 1 2. DESCRIPTION... 1 3. INSTALLATION...
More informationAddressable NAC Output Module D327A
Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,
More informationFor a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.
Power Supply/Chargers Installation Guide Models Include: eflow4na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow6na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow102na8d - 10A @ 12VDC - Eight
More informationPublic Safety DAS Annunciator Panel
Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This
More informationFor a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.
Power Supply/Chargers Installation Guide Models Include: eflow4na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow6na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow102na8-10a @ 12VDC - Eight
More informationSeries. Access Power Controllers. Installation Guide
Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse
More informationInstallation Guide for AL800UL-ADA. NAC Power Extender. Rev
Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA
More informationJuly 14, 1999 DF C-100.
www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,
More informationSeries SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual
Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual Part Number P84748 Assembly Number A84749 Revision C Revision A Copyright 2006 Printed in U.S.A. All rights reserved.
More informationMulti-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.
M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @
More informationAL800ULADA. NAC Power Extender. Installation Guide
AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery
More information30.45 Electric Release PDRP-2001
The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or
More informationFire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features
Fire Control Panels UL, ULC, CSFM Listed; FM Approved* Features Compatible with Simplex 4120 Network Converts multiple 4120 network communications signals into a single fiber optic link to: Multiplex audio
More information- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.
140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC
More informationTTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.
TTSIM-1A TraceTek Sensor Interface Module with Relay Installation Items (not supplied) General Information Installation/Operation Instructions Please read these instructions and keep them in a safe place.
More informationTrueAlarm Analog Sensing
TrueAlarm Analog Sensing UL, ULC Listed, CSFM Approved* Features Air aspiration duct smoke detection** system provides remote sensor location for ducts with difficult service access: Available as either
More informationAL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs
ACM Series Access Power Controllers with Power Supplies Installation Guide Models Include: AL400ULACM AL600ULACM - 12VDC @ 4 amp - 12VDC or 24VDC @ 6 amp. or 24VDC @ 3 amp - Fused Outputs - Fused Outputs
More informationRev. B. TrueAlert Addressable Controller Application Manual
574-996 Rev. B TrueAlert Addressable Controller Application Manual This page intentionally blank Copyrights and Trademarks Copyright 000 Simplex Time Recorder Company, Westminster, MA 044-000. All rights
More informationPSN-1000 & PSN 1000(E) Installation Manual
PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com
More informationAL600ULADA. NAC Power Extender. Installation Guide
AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery
More informationSAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT
W1 U8 AC N L SAFEPATH4 F2 IN BAT 24V TB7 TB1 AC TBL STB D11GRN YEL RED F1 D13 D14 AC SW1 SW2 RECORD D34 1 2 3 4 SP40/2 D9 D22 DV D10 D35 BAT MIC W2 ON D37 STB SHORT D39 STB OPEN 1 2 3 R SW3 1 2 3 4 TEL
More informationSimplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*
Simplex ES Network UL, ULC Listed* ES Net features ES Network (ES Net) is a high bandwidth (100 Mbps) IP based fire alarm network that supports up to 99 nodes and uses industry standard network technology
More informationConventional Fire Alarm Control Panel
Conventional Fire Alarm Control Panel INSTALLATION and OPERATION MANUAL NOTICE All information, documentation, and specifications contained in this manual are subject to change without prior notice by
More informationFire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.
UL, ULC Approved* Fire Control Panels Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting Features Converts multiple fire alarm communications signals into a single fiber optic
More informationRPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev
RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed
More informationInstallation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:
F1! 44487023 These instructions cover the following parts: PS902 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off AC power before installing or servicing PS902
More informationInstallation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger
Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger
More informationMulti-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.
M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp
More informationFCPS-24F/FCPS-24FE. Field Charger/Power Supply D P/N 50079:D ECN Installation, Operation and Application Manual
12 Clintonville Road Northford, CT 06472 203-484-7161 FAX: 203-484-7118 FCPS-24F/FCPS-24FE Field Charger/Power Supply Installation, Operation and Application Manual Document #50079 05/23/97 Rev: D P/N
More informationALARMS Fire Alarm Priority 2 Alarm. Fire Alarm Priority 2. Ack Event Time Enable Disable Emergency Operating Instructions.
ALARMS Fire Alarm Priority 2 Alarm Fire Alarm Event Time Enable Disable Emergency Operating Instructions Arm Disarm Priority 2 SYSTEM WARNINGS Supervisory Trouble Alarm Silenced Supv More Info Lamp Test
More informationTHERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16
TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and
More informationRectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English
Rectifier RC-series Manual RC-series English Manual Wall and 19 English Presentation The RC-series is a rectifier for either directly powering the load or for use together with batteries. It is designed
More information4007ES Fire Control Panels
UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* 4007ES Fire Control Panels 4007ES Hybrid, Fire Detection and Control Panel with Addressable and/or Conventional Initiation Features Satisfies a variety
More informationTTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS
TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must
More informationLong Range Radio Alarm Transmitter
TM Long Range Radio Alarm Transmitter INSTALLATION MANUAL Version 1.3W FEATURES Transmits alarm information to a long range radio network Varitech Transmission Format Note: If automatic SIA is used in
More information4007ES Fire Control Panels
UL, ULC, CSFM Listed; FM Approved* Features Flexible standard combination of addressable initiation and addressable notification 4.3 (109 mm) Diagonal color touchscreen display: Convenient and intuitive
More informationInstallation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger
Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control
More informationInstallation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:
Installation and Operating instructions for C9900-U330-0010 battery pack Version: 2.0 Date: 2017-03-23 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability
More informationIDP-Zone-6 Six Zone Interface Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Zone-6 Six Zone Interface Module BEFORE INSTALLING If the modules will be installed in an existing operational system, inform the operator and local authority
More information10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual
INSTALLATION 10-175UL Power Supply 10-175UL Access Control Power Supply/Charger Installation and Specifications Manual Overview The 10-175UL is a power limited power supply/charger that will convert 115VAC
More informationDual Input Toroidal Analyzer
Instruction Sheet PN 51A-1055T/rev.H February 2006 Model 1055 SOLU COMP II Dual Input Toroidal Analyzer Model Option 1055-21-31 For additional information, please refer to the Instruction Manuals CD shipped
More informationTrueAlert ES Addressable Notification Appliances
UL, ULC, CSFM Listed; FM Approved* TrueAlert ES Addressable Notification Appliances Visible Notification Appliances, Wall Mount Multi-Candela Strobes, Model Series 49VO Features Individually addressed
More informationFunctional Performance Test
Fire Alarm Control Panel & Fire Alarm Annunciator Panel Notify all building occupants that testing will be conducted. Fire alarm contractor shall have personnel with 2-way radios at the fire alarm control
More informationXPS and XNAC Installation Instructions
XPS and XNAC Installation Instructions Introduction This publication describes the installation procedure for 4100-5101 (120 VAC), 4100-5102 (220/230/240 VAC), and 4100-5103 (120 VAC with battery disconnect)
More informationTrueAlert Addressable Notification Appliances
UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone
More informationSecuritron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK
Installation Manual AQM-20 12vdc/24vdc Series Power Supplies AQM20 Supervised Power Supply/Charger 12vdc 20Amp/24vdc 10Amp Life Time Warranty Quality Manufactured in the USA AQM20 Features: The AQM20 has
More informationRMS/RPX Reader. User Manual
RMS/RPX Reader User Manual Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2005, GE Security Inc. All rights reserved. This document may not be copied or otherwise reproduced,
More informationUNC100 Integra Manual
UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant
More informationFIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -
FIRE FIRE 4100U Fire Alarm Operator's Manual 579-197 574-xxx Rev. Rev. B 4 Blank Page- Back of Front Cover Copyrights and Trademarks Copyright Simplex Time Recorder Co., 2001. All rights reserved. Printed
More informationMMF Six Zone Interface Module
Installation and Maintenance Instructions I56-900-005 MMF-0-6 Six Zone Interface Module SPECIFICATIONS Normal Operating Voltage: 5- VDC Stand-By Current: ma Alarm Current: 40 ma (assumes all six LEDs solid
More informationMR-2602 Two Zone Fire Alarm Control Panel
MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...
More information4007ES and 4007ES Hybrid Fire Alarm Systems Installation Manual
4007ES and 4007ES Hybrid Fire Alarm Systems Installation Manual *05791102H* This page is intentionally blank Contents CONTENTS 1 Cautions, Warnings, and Regulatory Information...3 2 Overview...4 2.1 4007ES
More informationRelease Control Fire Alarm Systems
SYSTEM ABORT PUSH AND HOLD COIL SUPERVISION MODULE (2 AMP) 2081-9046 RED INSTALLATION INSTRUCTIONS 574-437 REV YEL NAC+ MAINTAIN 1/4" SEPARATION BETWEEN POWER LIMITED (RED/) AND NONPOWER S LIMITED (YEL/)
More informationDual Input ph/orp Analyzer
Instruction Sheet PN 51A-1055pH/rev.I February 2006 Model 1055 SOLU COMP II Dual Input ph/orp Analyzer Model Option 1055-22-32 For additional information, please refer to the Instruction Manuals CD shipped
More informationJune 10, 2002 DF C S2424
GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other
More informationLifeAlarm Fire Alarm Control Panels
LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient
More information4100ES Fire Indicator Panel Installation & Maintenance
Fire 4100ES Fire Indicator Panel Installation & Maintenance Australian Installation Australian & Maintenance Manual Installation Manual LT0350 Iss 1.2 Copyrights and Trademarks 2006, 2012 Tyco Australia
More informationTECHNICAL DATA OBSOLETE
Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)
More informationTrueAlert Addressable Notification Appliances
UL, ULC, CSFM Listed, FM Approved TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances, Wall Mount Multi-Candela Horn/Strobe, Model Series 49AV Features Individually addressed
More informationFireNET Plus Wiring Instructions
FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to
More informationMS-2410BC. Conventional Fire Alarm Control Panel. Programming, Installation, Maintenance and Operating Instruction Manual
24 Viceroy Road Unit #6 & 7 Concord, Ontario L4K2L9 Phone (905) 660-7210 FAX: (905) 660-7204 MS-2410BC Conventional Fire Alarm Control Panel Programming, Installation, Maintenance and Operating Instruction
More informationAL600ULX Series. Power Supply/Charger. Installation Guide
AL600ULX Series Power Supply/Charger Installation Guide Models Include: AL600ULX - Single Output AL600ULPD4 AL600ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL600ULPD8 AL600ULPD8CB - Eight
More informationTECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.
September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.
More informationCertificate of Conformity Certificate num. Registration date Version Valid until
CSIRO Verification Services Highett, Victoria, Australia +61 (0)3 9252 6000 http://www.activfire.gov.au/ Page 1 of 7 Product designation Simplex, Model 4100U/4100U-S1/4100ES/4100ES-S1, fire indicator panel
More informationAL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev
AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated
More informationHarrington Signal HS-3100/3200 Fire Alarm Control Unit
HARRINGTON SIGNAL INC. FIRE ALARM Harrington Signal HS-3100/3200 Fire Alarm Control Unit Installation Manual Revision 2 January 2009 Document # LT-2000HAR Table of Contents 1.0 Technical Information...
More information