exsilentia Integrated Safety Lifecycle Tool

Size: px
Start display at page:

Download "exsilentia Integrated Safety Lifecycle Tool"

Transcription

1 Integrated Safety Lifecycle Tool Is it Tie to Upgrade Your Process Safety Tools to exsilentia Version 3? Design, operation and aintenance of Safety Instruented Systes (SIS) just got easier exsilentia Version 3 adds capabilities that will help users achieve a new level of consistency and productivity in the design of their Safety Instruented Systes (SIS). This release enhances the existing suite of tools, including the industry leading tool for Safety Integrity Level (SIL) verification ( ). All-new functionality allows users to follow the entire IEC 61511/ISA 84 functional safety lifecycle for the first tie using a single tool. It also supports copliance with regulations such as OSHA PSM (USA) and Seveso II (Europe). Enhanceents to the Existing exsilentia Suite All New Functionality Page 1 of 8

2 Follow the entire IEC / ISA 84 functional safety lifecycle using a single tool The use of a single tool for the whole safety lifecycle reduces total cost of ownership and helps ensure SIS applications are not over-designed or under-designed. It iproves traceability while also aking it easier to anage change, assess the ipact of design changes, and audit the overall design as required by industry regulations. exsilentia Version 3 is a odular suite of tools available in four different bundles: Standard Analysis Operations Ultiate This allows users to select the package that best eets their functionality requireents, budget, and addresses their specific engineering tasks. exsilentia Version 3 Options exsilentia V3.0 Packages Safety Lifecycle Phase / Activity exsilentia Module Module Functionality Standard Analysis Operation Ultiate Functional Safety Manageent, Auditing and Assessent IEC/ISA Copliance Docuentation Checklist for Docuenting Copliance with IEC / ISA Standard Safety Lifecycle Structure & Planning N/A Hazard & Risk Assessent (Process Hazard Analysis) PHAx * PHA Iport Record results of Process Hazards Analysis (PHA) / Hazard and Operability Study (HAZOP) Iport HAZOP results fro 3rd party tools Allocation of Safety Functions to Protection Layers (SIL Target Selection) SILAlar * Safety Integrity Level (SIL) Selection (Risk Graph Hazard Matrix, LOPA) Alar Rationalization per ISA18.2, EEMUA 191 Safety Requireents Specification (SRS) SRS C&E -- Process SRS Basic Safety Instruented Function Safety Requireents Specification Process level Safety Requireents Specification Safety Integrity Level Verification, IEC copliant calculation engine Design and Engineering of SIS (incl. SIL Verification) SERH Viewer * Lifecycle Cost Estiator Viewer for exida Safety Equipent Reliability Database (over 1700 devices) Evaluate Lifecycle cost of proposed SIF designs SRS C&E -- Design SRS Detailed Design level Safety Requireents Specification, creation of Cause & Effect atrices Installation, Coissioning and Validation Operation and Maintenance Modification N/A Proof Test Generator SILStat * Creates proof test procedures for each coponent (organized by SIF) Recording of SIF life event data (proof test results, failures, deands) for coparison of actual to expected perforance Decoissioning N/A Verification Built--in Peer review capability based on login allows review / approval of tool output Cost $ $$ $$ $$$ * Also Available Seperately Advanced GUI iproves the workflow process A new Graphical User Interface (GUI) provides a fresh look and feel to exsilentia, enhancing its usability and the copatibility between software odules. It allows resizing of SIF windows and provides zoo capabilities to accoodate a large variety of screen sizes / resolutions. This is ideal for presentation and review of SIS design results in a conference roo with a group of people. A spreadsheet-like overview is also provided to allow a quick coparison of data between Safety Instruented Functions (SIFs) gaining an overview of the SIS design, and anaging the exsilentia project with ease. Page 2 of 8

3 Identify and docuent process hazards with a new integrated tool The new PHAX tool guides users through the HAZOP process, facilitating effective identification of hazards, hazardous events, and associated sequence of events, siplifying the task of docuenting the results. Safeguards and recoendations identified as potential SIFs or alars can be recorded in a standard forat. PHAX supports sealess exchange of the PHA data to subsequent tasks in the safety lifecycle (SIL selection) and alar anageent lifecycle (rationalization) via integration with the exsilentia odules such as and SILAlar. This provides traceability and auditability by helping anage changes that ay ipact copliance with corporate risk criteria. The tool helps users eet industry regulations such as the Process Hazard Analysis requireent within OSHA PSM. Docuenting HAZOP results in PHAX If you already have a HAZOP tool, this is not a proble. exsilentia provides the ability to iport HAZOP results fro 3rd party tools (e.g., PHAWorks and PHA-Pro) allowing the data to be used for subsequent SIS design tasks such as SIL selection or alar rationalization. Mix and atch tolerable risk criteria during SIL Selection The exsilentia tool now includes the ability to ake use of different tolerable risk calibrations on a single project. It is now possible, for exaple, to use a ixture of risk graph, hazard atrix, and frequency based target (LOPA) approaches within one project. Also, allows a user to create their own risk graph or frequency-based targets, thus incorporating the functionality of the SILClass product. Using the Risk Graph Calibration wizard for SIL Selection Page 3 of 8

4 Enhanced SIL verification With exsilentia Version 3, the industry leading tool for SIL Verification () becae even better by adding capabilities requested by our users. The test interval of application level diagnostics like Partial Stroke Testing can now be specified. This helps address situations where partial stroke testing is not perfored 10X ore frequently than the proof test. can now also account for SIF dead tie, which is iportant in situations where the SIF is copletely bypassed during noral operation to execute a proof test. The ability to specify MooN (M-out-of-N) configurations during occasions when a standard architecture does not apply is another new feature of this product. Accoodating proof test deadtie in SIL Verification calculations Maxiize the risk reduction of the operator and alar syste protection layer through alar rationalization Available with exsilentia Ultiate, the SILAlar tool guides users through the alar rationalization process ensuring that every alar is justified, properly prioritized, and has a defined operator response as required by ISA-18.2 and EEMUA 191. Alar rationalization can eliinate alar overload, reduce the effect of alar floods, eliinate nuisance alars, and ensure that the operator has sufficient tie to respond (all of which helps achieve the expected level of risk reduction for this type of IPL). SILAlar allows HAZOP and LOPA results to be cross-referenced during the alar rationalization process ensuring that safety-critical alars are treated appropriately. Cross Reference Potential Consequences Corrective Action Docuenting operator response and creating HAZOP & LOPA cross references in SILAlar Page 4 of 8

5 Critical Device List provides increased visibility into IPLs Have you ever wondered if a particular relief valve was considered an Independent Protection Layer (IPL) soewhere in the SIL selection activity? This new feature generates a list of all devices defined in a project and cross references all IPLs where they are used, even non SIS risk-reduction easures. Built-in viewer for failure database siplifies gathering / coparing failure rate data exsilentia includes the world s ost extensive reliability database of instruentation and control equipent for use in Safety Instruented Systes, the Safety Equipent Reliability Handbook (SERH). Reliability data for over 1700 sensors, logic solvers, interface odules, and final eleents can be referenced directly during SIL verification, eliinating the tie-consuing task of gathering reliability data. This data can also be accessed through the SERH viewer, which allows users to copare reliability data by product, anufacturer, or type of assessent. The database is continuously updated as new products are introduced and assessed. Coon uses of the SERH include: Source of equipent reliability data for calculating the SIL of a safety instruented function (sensor logic solver final control eleent). A database that can be used to standardize reliability evaluations across a copany A tool for evaluating suppliers and equipent to create a preferred vendor list for SIS applications Critical Device List As a reference during SIL selection to estiate typical PFDs for coon types of equipent (e.g., valves). Viewing device failure rate data fro the SERH database Page 5 of 8

6 Docuent copliance with the IEC / ISA 84 standard A checklist for evaluating/deonstrating that your SIS design, operation, and aintenance activities coply with the IEC / ISA 84 standard is another addition. A coprehensive copliance atrix can be generated autoatically by exsilentia, with copliance arguents pre-entered for the requireents that are addressed based on usage of the tool. The reaining copliance arguents can be copleted by the user. The resultant docuent can be used to deonstrate to an auditor, assessor, or regulator how the requireents of the standard have been fulfilled. It can also be used as part of operating plant hazard reviews. Making upgrades cost effective and easy The odular design of exsilentia Version 3 supports an easy and cost-effective upgrade path fro version 2 based on your current level of functionality and the functionality desired. Project files created in earlier versions of exsilentia can be autoatically converted for use in the new version, ensuring no loss in productivity. exsilentia Version 2 exsilentia Version 3 Ultiate SILAlar SRS C&E Process & Design Functionality Standard Analysis Operations Lifecycle $ Estiator Proof Test Lifecycle $ Estiator Proof Test Basic (Version 2) Copliance Docuenter Copliance Docuenter Copliance Docuenter Copliance Docuenter SERH Viewer SERH Viewer SERH Viewer SERH Viewer 40% of Standard Upgrade Cost 40% of Standard 40% of Standard + Cost (Standard -> Analysis) + Cost (Standard -> Operation) 40% of Standard + Cost (Standard -> Ultiate) Upgrade paths fro exsilentia Version 2 to Version 3 Page 6 of 8

7 If your current exsilentia package includes optional plug-ins (SRS C&E, PHA Iport, Proof Test Generator, or Life- cycle Cost Estiator), then your upgrade path is defined below based on keeping equivalent functionality. SRS C&E PHA Iport Proof Test Generator Lifecycle Cost Estiator Coparable exsilentia Version 3 Package Upgrade Cost to Version 3 (Equivalent Functionality) Ultiate Analysis Operation Operation Operation Ultiate Ultiate Ultiate 40% of Ultiate Purchase Price 40% of Analysis Purchase Price 40% of Operation Purchase Price 40% of Operation Purchase Price 40% of Operation Purchase Price 40% of Ultiate Purchase Price 40% of Ultiate Purchase Price 40% of Ultiate Purchase Price Flexible licensing to support a variety of applications and project teas Four different licensing options for exsilentia are available in order to accoodate your safety engineering tea, whether co-located or distributed around the world. It also allows for teporary usage (subscriptions for 3, 6, and 12 onth online access) or long-ter usage allowing users to support projects of different durations. exsilentia Option Standalone Site Online Server Description License for a single user. Requires no special connectivity (can be used in the office or reotely) Multiuser license for 5 or 10 concurrent users. Users ust be connected to the sae network (subnet) as the license server for the application to run. Application is hosted reotely on an exida server. Users ust have a web browser on their local achines and the Citrix interface client installed to be able to access the application, as well as an internet connection. Projects can be stored on the exida servers as well as locally. Application and database(s) are hosted on the custoer s Citrix Presentation Server. Users ust have a web browser on their local achines and the Citrix interface client installed to be able to access the application. May 2011 Page 7 of 8

8 For ore inforation or to request a quote: Contact your local exida representative or visit our website at Gerany USA South Africa Asia Pacific exida.co GbH Birkensteinstr Fischbachau PHONE: exida.co LLC 64 North Main Street Sellersville, PA PHONE: exida South Africa PTY LTD Suite 1003, 34 Essex Terrace Westville, 3629, KZN PHONE: Collyer Quay #10-13, The Arcade Singapore PHONE: Switzerland Canada Mexico United Kingdo exida Certification SA Chein de Chap-Poury Genolier PHONE: exida Canada Ltd. 2nd Floor rd Street NE Calgary, Alberta T2E 7A4 Canada PHONE: exida Consulting Mexico Giorgione No. 6 Col. Nonoalco Mixocac Mexico, D.F Mexico PHONE: Hotchkiss Way Binley Industrial Estate Coventry CV3 2RL UK Phone: +44 (0) (0) Page 8 of 8

excellence in Dependable Automation

excellence in Dependable Automation excellence in Dependable Automation We help our clients improve the safety, security, and availability of their automation systems. contents About Us 4 What We Do 6 Certification Program 8 Services Available

More information

excellence in Dependable Automation ALARM MANAGEMENT

excellence in Dependable Automation ALARM MANAGEMENT excellence in Dependable Automation ALARM MANAGEMENT www.exida.com Improve the performance of your operators through effective Alarm Management. Typical alarm management issues that hamper operator performance

More information

IEC61511 Standard Overview

IEC61511 Standard Overview IEC61511 Standard Overview Andre Kneisel Instrumentation Engineer Chevron C.T. Refinery SAFA Symposium 2011 August 5 th, 2011 Presentation Overview Provide some understanding of the key aspects of Functional

More information

Practical Methods for Process Safety Management

Practical Methods for Process Safety Management Practical Methods for Process Safety Management Putting Process Safety Management At The Heart Of Our Lives Canadian Chemical Engineering Conference 2006 October 18, 2006 CSChE Conference 2006 Quote Concern

More information

REPRINT ZKG PROCESS PROCESS

REPRINT ZKG PROCESS PROCESS 4 Planning detail for integration of the into the existing plant peripherals a rotary feeder, the otor for 180 t/h of raw eal, for exaple, has a rating of 5.5 and during operation it uses less than 1.

More information

IEC Functional Safety Assessment

IEC Functional Safety Assessment IEC 61508 Functional Safety Assessment Project: Detcon IR-700 Combustible Hydrocarbon Gas Sensor Customer: Detcon The Woodlands, TX USA Contract No.: Q13/06-003 Report No.: DC 13-06-003 R002 Version V1,

More information

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd. Process Safety - Market Requirements V.P.Raman Mott MacDonald Pvt. Ltd. Objective of Process Safety Protect personnel Protect the environment Protect the plant equipment / production. Multiple Layers

More information

PRODUCT INFORMATION FWE200DH EXTRACTIVE SCATTERED LIGHT DUST MEASURING DEVICE RELIABLE DUST MEASUREMENT IN WET GASES. Dust measuring devices

PRODUCT INFORMATION FWE200DH EXTRACTIVE SCATTERED LIGHT DUST MEASURING DEVICE RELIABLE DUST MEASUREMENT IN WET GASES. Dust measuring devices PRODUCT INFORMATION FWE200DH EXTRACTIVE SCATTERED LIGHT DUST MEASURING DEVICE RELIABLE DUST MEASUREMENT IN WET GASES Dust easuring devices RELIABLE DUST MEASUREMENT IN WET GASES Particle easureent in a

More information

PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE

PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE Summary From the perspective of process safety, the most notable change is the addition of requirements for

More information

2015 Functional Safety Training & Workshops

2015 Functional Safety Training & Workshops HAZAN RISK SIS SIF - IEC 61508/61511 - SIL PFD SFF CCF 2015 Functional Safety Training & Workshops Select the right course for your organisation from our extensive choice of Functional Safety related training

More information

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd Abstract Session Four Functional safety: the next edition of IEC 61511 Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd The functional safety standard IEC 61511 provides a framework for managing

More information

InstrumentationTools.com

InstrumentationTools.com Author: Instrumentation Tools Categories: Safety Systems S84 / IEC 61511 Standard for Safety Instrumented Systems IEC 61511 is a technical standard which sets out practices in the engineering of systems

More information

Functional Safety: the Next Edition of IEC 61511

Functional Safety: the Next Edition of IEC 61511 HazAus2015/1507 Functional Safety: the Next Edition of IEC 61511 Mirek Generowicz Engineering Manager I&E Systems Pty Ltd Level 2, 445 Hay Street Perth WA 6000 Abstract The functional safety standard IEC

More information

Benchmarking Industry Practices for the Use of Alarms as Safeguards and Layers of Protection

Benchmarking Industry Practices for the Use of Alarms as Safeguards and Layers of Protection Benchmarking Industry Practices for the Use of Alarms as Safeguards and Layers of Protection Todd Stauffer, PE exida Consulting 64 N. Main Street, Sellersville, PA tstauffer@exida.com Dr. Peter Clarke,

More information

PRODUCT INFORMATION VICOTEC320 AIR QUALITY TUNNEL SENSORS TO CONTROL VENTILATION IN ROAD TUNNELS. Tunnel sensors

PRODUCT INFORMATION VICOTEC320 AIR QUALITY TUNNEL SENSORS TO CONTROL VENTILATION IN ROAD TUNNELS. Tunnel sensors PRODUCT INFORMATION VICOTEC320 AIR QUALITY TUNNEL SENSORS TO CONTROL VENTILATION IN ROAD TUNNELS Tunnel sensors RELIABLE AIR QUALITY MEASUREMENT IN ROAD TUNNELS Continuously onitoring air quality and visibility

More information

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry 1. Introduction Author: Colin Easton ProSalus Limited ~ Independent Safety Consultants Within the United

More information

ADIPEC 2013 Technical Conference Manuscript

ADIPEC 2013 Technical Conference Manuscript ADIPEC 2013 Technical Conference Manuscript Name: Heidi Fuglum Company: ABB AS Job title: Deployment Manager Address: Ole Deviksvei, Oslo, Norway Phone number: +47 91 36 98 70 Email: Heidi.Fuglum@no.abb.com

More information

Safety Integrity Verification and Validation of a High Integrity Pressure Protection System to IEC 61511

Safety Integrity Verification and Validation of a High Integrity Pressure Protection System to IEC 61511 TÜV Rheinland International Symposium in China Functional Safety in Industrial Applications October 18 19, 2011 in Shanghai China Safety Integrity Verification and Validation of a High Integrity Pressure

More information

NVIRO. Environmental Test Chambers

NVIRO. Environmental Test Chambers NVIRO Environental Test Chabers VIRO Environental Test Chabers VIRO Environental Test Chabers are uniquely designed and built for long life perforance and lasting reliability with typical features to suit

More information

Addressing Challenges in HIPPS Design and Implementation

Addressing Challenges in HIPPS Design and Implementation Addressing Challenges in HIPPS Design and Implementation Valve Manufacturer s Association Afton Coleman, CFSP March 11, 2016 Agenda SIS and SIL basics HIPPS Purpose Increased demand for HIPPS, why? The

More information

Implementing Safety Instrumented Burner Management Systems: Challenges and Opportunities

Implementing Safety Instrumented Burner Management Systems: Challenges and Opportunities Implementing Safety Instrumented Burner Management Systems: Challenges and Opportunities Mike Scott, PE, CFSE Standards Certification Education & Training Publishing Conferences & Exhibits Presenter Mike

More information

Functional Safety Application of IEC & IEC to asset protection

Functional Safety Application of IEC & IEC to asset protection Functional Safety Application of IEC 61508 & IEC 61511 to asset protection Paulo Oliveira Engineering Manager Engineering Safety Consultants Ltd Engineering Safety Consultants Limited Page 1 Agenda Agenda

More information

Where Process Safety meets Machine Safety

Where Process Safety meets Machine Safety Where Process Safety meets Machine Safety A document to aid understanding between the end-user and machine builder for functional safety issues. by The 61508 Association Overriding key principle...it must

More information

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators Rev 0, November 17 2015 Page 1 of 9 Table of Contents 1 INTRODUCTION 3 1.1 Terms and abbreviations 3 1.2 Acronyms 4 1.3

More information

Options for Developing a Compliant PLC-based BMS

Options for Developing a Compliant PLC-based BMS Options for Developing a Compliant PLC-based BMS Jack Boone aesolutions Greenville, South Carolina, United States of America ABSTRACT Facilities are focusing on improving the reliability of their burner

More information

Safety Instrumented Systems Overview and Awareness. Workbook and Study Guide

Safety Instrumented Systems Overview and Awareness. Workbook and Study Guide Safety Instrumented Systems Overview and Awareness Workbook and Study Guide V 1.0 Preface Copyright Notice and Disclaimer Copyright 2017, Kenexis Consulting Corporation All Rights Reserved 3366 Riverside

More information

Safety Instrumented Systems

Safety Instrumented Systems Safety Instrumented Systems What is a Safety Instrumented System? A Safety Instrumented System SIS is a new term used in standards like IEC 61511 or IEC 61508 for what used to be called Emergency Shutdown

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Fireye Flame Sensor Module CE Flameswitch, model MBCE-110/230FR Company: Fireye Derry, NH USA Contract Number: Q09/10-26 Report No.: FIR 09/10-26

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Detcon FP-700 Combustible Gas Sensor Customer: Detcon The Woodlands, TX USA Contract No.: DC 06/08-04 Report No.: DC 06/08-04 R001 Version V1, Revision

More information

Changes in IEC Ed 2

Changes in IEC Ed 2 1 Introduction As known IEC 61511 is the applicable standard for functional safety in the process industry. Defining the requirements for the specification, design, installation, operation and maintenance

More information

Alarm Management Services

Alarm Management Services Alarm Management Services Know and improve alarm performance Integrate compeletely with almost any control system Increase operator efficiency Comply with regulatory and industry standards The Value of

More information

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring DeltaV Distributed Control System Product Data Sheet December 2016 DeltaV Analyze Continuous automated DeltaV System alarm system performance monitoring Trends of alarms, events, and user actions Identification

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Type 95IR/95UV/95DS Flame Scanners Customer: FIREYE Derry, New Hampshire USA Contract No.: FIR 04/08-21 Report No.: FIR 04/08-21 R002 Version V1,

More information

United Electric Controls One Series Safety Transmitter Safety Manual

United Electric Controls One Series Safety Transmitter Safety Manual United Electric Controls One Series Safety Transmitter Safety Manual OneST-SM-02 1 INTRODUCTION This Safety Manual provides information necessary to design, install, verify and maintain a Safety Instrumented

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61511-3 First edition 2003-03 Functional safety Safety instrumented systems for the process industry sector Part 3: Guidance for the determination of the required safety integrity

More information

Process Safety Workshop. Avoiding Major Accident Hazards the Key to Profitable Operations

Process Safety Workshop. Avoiding Major Accident Hazards the Key to Profitable Operations CC & technical support services www.silsupport.com Process Safety Workshop Avoiding Major Accident Hazards the Key to Profitable Operations A two (2) day workshop with many practical methods, case studies

More information

Session Number: 3 Making the Most of Alarms as a Layer of Protection

Session Number: 3 Making the Most of Alarms as a Layer of Protection Session Number: 3 Making the Most of Alarms as a Layer of Protection Abstract Todd Stauffer Director Alarm Management Services, exida LLC Alarms and operator response are one of the first layers of protection

More information

Certification Report of the ST3000 Pressure Transmitter

Certification Report of the ST3000 Pressure Transmitter Certification Report of the ST3000 Pressure Transmitter Revision No.: 1.0 Date: Report Number: Product: Customer: Order Number: Authority: Responsible: 2006-Dec-12 SAS-128/2006T ST3000 Pressure Transmitter

More information

Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors

Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors Description The Eagle Series of PIR-018, PIR-045 and PIR-100 Outdoor Passive Infrared Detectors are designed for detection of intruders

More information

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

Australian Standard. Functional safety Safety instrumented systems for the process industry sector AS IEC 61511.2 2004 IEC 61511-2:2003 AS IEC 61511.2 Australian Standard Functional safety Safety instrumented systems for the process industry sector Part 2: Guidelines for the application of AS IEC 61511.1

More information

Safety Instrumented Fire & Gas Systems

Safety Instrumented Fire & Gas Systems Safety Instrumented Fire & Gas Systems aesolutions Provides Full-Service Fire & Gas Engineering and Products The aesolutions FM-approved family of Fire & Gas safety systems ensures compliance with the

More information

Alarm Services. Introduction. Benefits. Service Data Sheet October Know and improve your alarm performance

Alarm Services. Introduction. Benefits. Service Data Sheet October Know and improve your alarm performance Service Data Sheet Alarm Services Know and improve your alarm performance Integrate completely with your DCS Increase your operator efficiency Comply to regulatory and industry standards The Alarm Services

More information

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update Technical Paper Functional Safety Update IEC 61511 Edition 2 Standards Update Functional Safety Update Table of Contents 1.0 Introduction 2.0 IEC 61511-1 changes 3.0 IEC 61511-2 changes 4.0 IEC 61511-3

More information

Beyond Compliance Auditing: Drill til you find the pain points and release the pressure!

Beyond Compliance Auditing: Drill til you find the pain points and release the pressure! Beyond Compliance Auditing: Drill til you find the pain points and release the pressure! Laura Ankrom, P.E. aesolutions, Inc. 250 Commonwealth Drive, Ste. 200, Greenville, SC 29615 Laura.ankrom@aesolns.com

More information

Sustain.Ability. Alarm Management: Be Pro-active, not Re-active Honeywell Users Group Europe, Middle East and Africa. Tyron Vardy, Honeywell

Sustain.Ability. Alarm Management: Be Pro-active, not Re-active Honeywell Users Group Europe, Middle East and Africa. Tyron Vardy, Honeywell Sustain.Ability. 2012 Honeywell Users Group EMEA 2014 Honeywell Users Group Europe, Middle East and Africa Alarm Management: Be Pro-active, not Re-active Tyron Vardy, Honeywell Agenda Introduction Defining

More information

Session Ten: The importance of a clear Safety Requirements Specification as part of the overall Safety Lifecycle

Session Ten: The importance of a clear Safety Requirements Specification as part of the overall Safety Lifecycle Session Ten: The importance of a clear Safety Requirements Specification as part of the overall Safety Lifecycle Abstract Andy Crosland SIS Business Development Manager, Europe Emerson Process Management

More information

Safety Instrumented Systems The Smart Approach

Safety Instrumented Systems The Smart Approach Safety Instrumented Systems The Smart Approach The Emerson Approach to Safety More than ever, running your plant productively and safely requires the right technologies and experience. With increasingly

More information

100 & 120 Series Pressure and Temperature Switches Safety Manual

100 & 120 Series Pressure and Temperature Switches Safety Manual 100 & 120 Series Pressure and Temperature Switches Safety Manual MECH-SM-01 1 INTRODUCTION This Safety Manual provides information necessary to design, install, verify and maintain a Safety Instrumented

More information

Digital EPIC 2 Safety manual

Digital EPIC 2 Safety manual Safety manual Before installation these instructions must be fully read and understood Table of contents Safety manual... 1 1. Introduction... 1 1.1 Terms and abbreviations... 2 1.2 Acronyms... 2 1.3 Product

More information

THE GREAT BRITISH BOILER. Visit Call Get advice, latest prices and help on choosing the right boiler for you.

THE GREAT BRITISH BOILER. Visit   Call Get advice, latest prices and help on choosing the right boiler for you. Flue Options The standard flue is suitable only for horizontal terination applications. Maxiu perissible equivalent flue lengths are: Horizontal Concentric / etres Vertical Centric / etres Vertical Twin

More information

New requirements for IEC best practice compliance

New requirements for IEC best practice compliance New requirements for IEC 61511 best practice compliance Proof testing and a SIL study may no longer be enough by Sven Grone Schneider Electric Safety Services Practice Leader Executive summary Since its

More information

Extension of a Virtual Refrigerant Charge Sensor

Extension of a Virtual Refrigerant Charge Sensor Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Extension of a Virtual Refrigerant Charge Sensor Woohyun i ki644@purdue.edu

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Honeywell Temperature Transmitter STT650 with 4-20 ma Output Company: Honeywell International Inc. Field Products 512 Virginia Drive Fort Washington,

More information

2015 Honeywell Users Group Europe, Middle East and Africa

2015 Honeywell Users Group Europe, Middle East and Africa 2015 Honeywell Users Group Europe, Middle East and Africa Safety System Lifecycle Support and Honeywell s capabilities in Industrial Fire & Gas Johan School, Honeywell (Product Manager Safety Systems)

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Oldham OLCT 200 Transmitter Company: Industrial Scientific Corporation Oakdale, PA USA Contract Number: Q11/05-009 Report No.: IS 10/10-010 R001

More information

PLANNING REPORT PROPOSED RESIDENTIAL PLAN OF SUBDIVISION

PLANNING REPORT PROPOSED RESIDENTIAL PLAN OF SUBDIVISION PLANNING REPORT PROPOSED RESIDENTIAL PLAN OF SUBDIVISION Part Lot 51, Lake Range Geographic County of Bruce Owner: Mystic Cove Developents Inc. Prepared by: Ron Davidson Land Use Planning Consultant Inc.

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Phoenix Type 85UVF/IRF Flame Scanner Company: FIREYE Derry, New Hampshire USA Contract Number: Q08/04-57 Report No.: FIR 08/04-57 R001 Version V2,

More information

PRODUCT PORTFOLIO OVERVIEW SENSOR SOLUTIONS: FOR MORE EFFICIENT AUTOMATION. Sensors, systems, and services

PRODUCT PORTFOLIO OVERVIEW SENSOR SOLUTIONS: FOR MORE EFFICIENT AUTOMATION. Sensors, systems, and services PRODUCT PORTFOLIO OVERVIEW SENSOR SOLUTIONS: FOR MORE EFFICIENT AUTOMATION Sensors, systes, and services SEAMLESSLY NETWORKED INDUSTRIAL COMMUNICATION AND SENSOR INTEGRATION Networked production and control

More information

Managing the Lifecycle of Independent Protection Layers

Managing the Lifecycle of Independent Protection Layers Managing the Lifecycle of Independent Protection Layers Patrick Fisher, Provenance Consulting, October 6, 2016 Overview What is an IPL? When is a safeguard an IPL? What makes a good IPL? What criteria

More information

Technical Description

Technical Description Overview are differentiated depending on applied edia. Light, one of the edia, is also utilized for a which is called a photoelectric. It is a non-contact type which is applicable to sensing presence,

More information

Technical Description

Technical Description Overview are differentiated depending on applied edia. Light, one of the edia, is also utilized for a which is called a photoelectric. It is a non-contact type which is applicable to sensing presence,

More information

Certification Report of the ST 3000 Pressure Transmitter with HART 6

Certification Report of the ST 3000 Pressure Transmitter with HART 6 Certification Report of the ST 3000 Pressure Transmitter with HART 6 Revision No.: 2.4 Date: Report Number: 2010-Mar-18 SAS-190/2006T Product: ST 3000 Pressure Transmitter with HART 6 Customer: Order Number:

More information

PPA Michaël GROSSI - FSCE PR electronics

PPA Michaël GROSSI - FSCE PR electronics Functional Safety Component selection according to IEC61511 Title 2 Presentation Michaël GROSSI: Ex / SIL Product manager @ Degree in Instrumentation & Measurement More than 10 years experience in Functional

More information

Technical Description

Technical Description overview Sensors are differentiated depending on applied edia. Light, one of the edia, is also utilized for a which is called a photoelectric. It is a non-contact type which is applicable to sensing presence,

More information

Strathayr, Rhu-Na-Haven Road, Aboyne, AB34 5JB, Aberdeenshire, U.K. Tel: +44 (0)

Strathayr, Rhu-Na-Haven Road, Aboyne, AB34 5JB, Aberdeenshire, U.K. Tel: +44 (0) Strathayr, Rhu-Na-Haven Road, Aboyne, AB34 5JB, Aberdeenshire, U.K. Tel: +44 (0)1339 886618 www.silsupport.com 2012 TRAINING TÜV FS Engineer Certification Training (4 days) This 4 day course is run in

More information

Precision Air Conditioners

Precision Air Conditioners MCAC-- Coercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: est region of Midea coercial air conditioner departent, Industry Avenue, Beijiao, Shunde, Foshan, Guangdong,

More information

Karl Watson, ABB Consulting Houston LOPA. A Storage Tank Case Study. ABB Inc. September 20, 2011 Slide 1

Karl Watson, ABB Consulting Houston LOPA. A Storage Tank Case Study. ABB Inc. September 20, 2011 Slide 1 Karl Watson, ABB Consulting Houston LOPA A Storage Tank Case Study September 20, 2011 Slide 1 Introduction Karl Watson PSM Consultant, ABB Consulting Based in Houston, US Chartered Instrument Engineer

More information

67 th Canadian Chemical Engineering Conference EDMONTON, AB OCTOBER 22-25, 2017

67 th Canadian Chemical Engineering Conference EDMONTON, AB OCTOBER 22-25, 2017 Canadian Society for Chemical Engineering (CSChE) 67 th Canadian Chemical Engineering Conference EDMONTON, AB OCTOBER 22-25, 2017 MONDAY, 23 OCTOBER, 2017 Guillermo Pacanins, P. Eng., FS Senior Expert

More information

Session Ten Achieving Compliance in Hardware Fault Tolerance

Session Ten Achieving Compliance in Hardware Fault Tolerance Session Ten Achieving Compliance in Hardware Fault Tolerance Mirek Generowicz FS Senior Expert (TÜV Rheinland #183/12) Engineering Manager, I&E Systems Pty Ltd Abstract The functional safety standards

More information

Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013)

Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013) Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013) Question Answer from Kevin Brown Can you define HAZOP and LOPA? HAZOP stands for Hazard and Operability Study. LOPA stands for Layers of

More information

Measurement of Safety Integrity of E/E/PES according to IEC61508

Measurement of Safety Integrity of E/E/PES according to IEC61508 Measurement of Safety Integrity of E/E/PES according to IEC61508 Mr. Chen Zhenkang TUV Rheinland Singapore 18. May. 2018 Singapore World Metrology Day 2018 1 Agenda 1. TÜV Rheinland: a Certification Body

More information

PRODUCT PORTFOLIO OVERVIEW SENSOR SOLUTIONS: FOR MORE EFFICIENT AUTOMATION. Sensors, systems and services

PRODUCT PORTFOLIO OVERVIEW SENSOR SOLUTIONS: FOR MORE EFFICIENT AUTOMATION. Sensors, systems and services PRODUCT PORTFOLIO OVERVIEW SENSOR SOLUTIONS: FOR MORE EFFICIENT AUTOMATION Sensors, systes and services INDUSTRIAL COMMUNICATION AND DEVICE INTEGRATION EASY INTEGRATION INTO YOUR AUTOMATION WORLD Sensor

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: 3144P 4-20mA HART Temperature Transmitter Device Label SW REV 1.1.X Customer: Rosemount Inc. (an Emerson Process Management company) Shakopee, MN

More information

ENGINEERING STANDARD FOR FIRE-FIGHTING SPRINKLER SYSTEMS ORIGINAL EDITION. Nov. 1993

ENGINEERING STANDARD FOR FIRE-FIGHTING SPRINKLER SYSTEMS ORIGINAL EDITION. Nov. 1993 ENGINEERING STANDARD FOR FIRE-FIGHTING SPRINKLER SYSTEMS ORIGINAL EDITION Nov. 1993 This standard specification is reviewed and updated by the relevant technical coittee on Jan. 2000. The approved odifications

More information

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System White Paper Project: Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System Version 1, Revision 2, August 4, 2016 Jim Jenkins, William Goble The document was prepared using

More information

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices EPLE03-17 -WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices NEW FCQ-B indoor unit FCQ35/50/60B7 wired reote control (optional) central reote control (optional)

More information

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION DATA SHEET BENEFITS Alarm Printers, Report Printer Replacement Better Operator Attention Alarm Rationalization Remote Viewing of Alarms Unlimited Archiving of Alarms\Event Messages Alarm Consolidation

More information

Fire and Gas Detection and Mitigation Systems

Fire and Gas Detection and Mitigation Systems Fire and Gas Detection and Mitigation Systems Dr. Lawrence Beckman, PE, TÜV FSExp SafePlex Systems, Inc., Houston, Texas ABSTRACT Fire and Gas Detection systems are key components in the overall safety

More information

Safety in the process industry

Safety in the process industry Products Solutions Services Safety in the process industry Simply reliable Table of contents Endress+Hauser: At home in the process safety Smart devices and concepts for hazardous areas Introduction to

More information

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK USEFUL TERMINOLOGY BASIC PROCESS CONTROL SYSTEM (BPCS) System which responds to input signals from the process, its associated equipment, other programmable

More information

MHI Centrifugal Chiller

MHI Centrifugal Chiller MHI Centrifugal Chiller Constant speed Variable speed HFC-134a GART GART-I & series 1934kW(RT) ~18986kW(4RT) MHI Centrifugal Chiller Constant speed Variable speed HFC-134a GART & GART-I series GART-H GART-HI

More information

Research Article Reconfigurable and Reusable Mutual Module Based Parameterization Approach for DWT and FFT Algorithm

Research Article Reconfigurable and Reusable Mutual Module Based Parameterization Approach for DWT and FFT Algorithm Research Journal of Applied Sciences, Engineering and Technology 7(22): 4706-4713, 2014 DOI:10.19026/rjaset.7.855 ISSN: 2040-7459; e-issn: 2040-7467 2014 Maxwell Scientific Publication Corp. Subitted:

More information

Is your current safety system compliant to today's safety standard?

Is your current safety system compliant to today's safety standard? Is your current safety system compliant to today's safety standard? Abstract It is estimated that about 66% of the Programmable Electronic Systems (PES) running in the process industry were installed before

More information

Dry. The vacuum kiln. V-Basic V-Comfort V-Premium. energy saving efficient

Dry. The vacuum kiln. V-Basic V-Comfort V-Premium. energy saving efficient drying systes DRY The vacuu kiln energy saving efficient Actively pursuing a cliateneutral industry - because wood is our passion Vacuu kilns for sawn and construction tiber ranging fro 1.5 ³ to 100 ³

More information

Topic MYTH FUNCTIONAL SAFETY IMPLIES HAVING A SIL RATED COMPONENT. Presented by : Arunkumar A

Topic MYTH FUNCTIONAL SAFETY IMPLIES HAVING A SIL RATED COMPONENT. Presented by : Arunkumar A Topic MYTH FUNCTIONAL SAFETY IMPLIES HAVING A SIL RATED COMPONENT Presented by : Arunkumar A DNV GL Who are we? Only by connecting the details can we impact the bigger picture We classify, certify, verify

More information

IEC an aid to COMAH and Safety Case Regulations compliance

IEC an aid to COMAH and Safety Case Regulations compliance IEC 61511 an aid to COMAH and Safety Case Regulations compliance C R Timms, Director, C&C Technical Support Services Limited INTRODUCTION There are specific safety related regulations for the UK offshore

More information

Integrated but separate

Integrated but separate End users of older automation systems essentially had to invest in two separate systems: a basic process control system and a separate safety instrumented system. Nowadays, suppliers differ in their opinions

More information

ANALYSIS OF HUMAN FACTORS FOR PROCESS SAFETY: APPLICATION OF LOPA-HF TO A FIRED FURNACE. Paul Baybutt Primatech Inc. and

ANALYSIS OF HUMAN FACTORS FOR PROCESS SAFETY: APPLICATION OF LOPA-HF TO A FIRED FURNACE. Paul Baybutt Primatech Inc. and ANALYSIS OF HUMAN FACTORS FOR PROCESS SAFETY: APPLICATION OF LOPA-HF TO A FIRED FURNACE by Paul Baybutt Primatech Inc. and Joel Haight The Pennsylvania State University Abstract Layers of Protection Analysis

More information

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions Honeywell.com 2014 Honeywell Users Group Europe, Middle East and Africa Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions 1 Erik de Groot, Honeywell Document control number

More information

Failure Rate Data, Safety System Modeling Concepts, and Fire & Gas Systems Moderator: Lori Dearman, Webinar Producer Thursday, May 16th, 2013

Failure Rate Data, Safety System Modeling Concepts, and Fire & Gas Systems Moderator: Lori Dearman, Webinar Producer Thursday, May 16th, 2013 Welcome to Best Practices for the Latest Safety Instrumented System Performance Developments Failure Rate Data, Safety System Modeling Concepts, and Fire & Gas Systems Moderator: Lori Dearman, Webinar

More information

DeltaV Analyze. DeltaV Analyze. Introduction. DeltaV Product Data Sheet. Continuous automated DeltaV System alarm system performance monitoring

DeltaV Analyze. DeltaV Analyze. Introduction. DeltaV Product Data Sheet. Continuous automated DeltaV System alarm system performance monitoring January 2013 Page 1 DeltaV Analyze The DeltaV Analyze Overview page summarizes your plant alarm and event performance. Continuous automated DeltaV System alarm system performance monitoring Trends of alarms,

More information

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No User s Manual YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters Manual Change No. 16-045 Please use this manual change for the manuals listed below. 1. Applicable manuals, revised item, revised

More information

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA Failure Modes, Effects and Diagnostic Analysis Project: 2088 Pressure Transmitter Customer: Rosemount Inc. Chanhassen, Minnesota USA Contract No.: ROS 06/10-18 Report No.: ROS 06/10-18 R001 Version V1,

More information

SIMULATION STUDY ON HEAT TRANSFER RATE ON AIR CONDITIONING CONDENSER BY VARYING MATERIAL PROPERTIES AND ORIENTATION

SIMULATION STUDY ON HEAT TRANSFER RATE ON AIR CONDITIONING CONDENSER BY VARYING MATERIAL PROPERTIES AND ORIENTATION SIMULATION STUDY ON HEAT TRANSFER RATE ON AIR CONDITIONING CONDENSER BY VARYING MATERIAL PROPERTIES AND ORIENTATION MUNIGONDA VIJAY KUMER M.TECH (theral engineering) MLR Institute of Technology, Hyderabad.

More information

Using HAZOP/LOPA to Create an Effective Mechanical Integrity Program

Using HAZOP/LOPA to Create an Effective Mechanical Integrity Program Using HAZOP/LOPA to Create an Effective Mechanical Integrity Program Steven T. Maher, PE CSP & David J. Childs 949/282-0123 www.rmpcorp.com Download Presentation & Handout www.sems1.com/gcps/2017.htm Steven

More information

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs Meet Today s Cost and Complexity Challenges Industrial process plants are trying to reduce their process control and safety

More information

Key Topics. Steven T. Maher, PE CSP. Using HAZOP/LOPA to Create an Effective Mechanical Integrity Program. David J. Childs

Key Topics. Steven T. Maher, PE CSP. Using HAZOP/LOPA to Create an Effective Mechanical Integrity Program. David J. Childs Steven T. Maher, PE CSP Using HAZOP/LOPA to Create an Effective Mechanical Integrity Program Steven T. Maher, PE CSP & 949/282-0123 www.rmpcorp.com 37-Year Engineer 33 in Process Safety Consulting Specializing

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Rosemount 3051SMV MultiVariable Transmitter Company: Emerson Automation Solutions Rosemount Inc. Shakopee, MN USA Contract Number: Q16/12-041 Report

More information

Alarm Management Standards Are You Taking Them Seriously?

Alarm Management Standards Are You Taking Them Seriously? Alarm Management Standards Are You Taking Them Seriously? Executive Summary EEMUA Publication 191 ALARM SYSTEMS - A Guide to Design, Management, and Procurement was first released in 1999 and is well acknowledged

More information

PRELIMINARY. w w w. d a i k i n e u r o p e. c o m FDQ-B

PRELIMINARY. w w w. d a i k i n e u r o p e. c o m FDQ-B PRELIMINARY Daikin air conditioners for large spaces CONCealed ceiling unit w w w. d a i k i n e u r o p e. c o FDQ-B Concealed ceiling units are built into the false ceiling, leaving only the suction

More information