VISY-X. Technical Documentation. VISY-SoftView V 1.7 User Guide for VISY-Command GUI and VISY-View Touch. Edition: Version: 6 Art.

Size: px
Start display at page:

Download "VISY-X. Technical Documentation. VISY-SoftView V 1.7 User Guide for VISY-Command GUI and VISY-View Touch. Edition: Version: 6 Art."

Transcription

1 Technical Documentation VISY-X VISY-SoftView V 1.7 User Guide for VISY-Command GUI and VISY-View Touch Edition: Version: 6 Art. No: FAFNIR GmbH Bahrenfelder Str Hamburg, Germany Tel.: +49 /40 / Fax: +49 / 40 /

2 Table of contents 1 Overview Safety instructions Module description VISY-SoftView Starter VISY-SoftView Main screen in the standard mode Main screen in the TD mode (Tank Driver mode) Date and time System messages FAFNIR logo Tank display Tank details... 9 Tank Graphics Tank Configuration Measurement Values Alarms Age of Data RF Field strength RF Battery Function keys Reports and Configuration (system functions) Deliveries List field Delivery entry details window Speed button: Configuration Static Leak Detection (report function all tanks) List field, Static Leak Detection (SLD) Detail view Print, Details Display of unfinished SLD Static Leak Detection (report function individual tank) Call up from "Tank Details" view I Table of contents

3 2. SLD Report function individual tank Detail view Work Mode Oil separator Operating state Maintenance State Screen Cleaning Alarms New alarms Alarm selection Tank alarms (Tank probes) Environmental alarms (Environmental sensors) Environmental sensors Overview of all probes and device types Designations Probes and devices of one type Individual probe or individual device Tanks Print Home button List of figures Copyright: Reproduction and translation is permitted only with the written consent of the FAFNIR GmbH. The FAFNIR GmbH reserves the right to make product alterations without prior notice. Table of contents II

4 1 Overview The display module of the FAFNIR products VISY-Command GUI and VISY-View Touch can be used as an alternative to a petrol station computer for displaying and analysing the fuel data. Representation of the tank data, delivery data and various alarms is done on a coloured TFT screen. All functions are accessible using the touch screen user interface. The software VISY-SoftView is firmware for this display module. Alarms are visually shown by the display module and are also audibly signalled by a buzzer. As an option, a printer can be connected to the serial port. This documentation describes the usage of VISY-SoftView. For configuring VISY- SoftView like an administrator, see the following manual: Technical Documentation VISY-SoftView Administrator, art. no For use of Oil Separators (OS) with VISY-Stick probes as data source, a separate guide for configuration and use of VISY-SoftView is available: VISY-SoftView Oil Separator, art. no All significant configuration data, alarms and product data, VISY-SoftView obtains from VISY-Command. For instructions on how to install and operate VISY-Command, see following manuals: Technical Documentation VISY-Command, art. no Technical Documentation VISY-View Touch, art. no VISY-Command must be setup with the VISY-Setup configuration software. For instructions on how to configure with VISY-Setup, see: Technical Documentation VISY-Setup V4, art. no Page 1/48 Overview

5 1.1 Safety instructions The VISY-SoftView software application is intended for use in petrol stations. The software provides the capability to evaluate filling levels and to monitor tanks and their supply pipes. The system must be used exclusively for this purpose. Please observe and follow all product safety notes and operating instructions. The manufacturer accepts no liability for any form of damage resulting from improper use! VISY-Command GUI and VISY-View Touch, on which the VISY-SoftView software application is installed, have been developed, manufactured and tested in accordance with the latest good engineering practices and generally accepted safety standards. Nevertheless, hazards may arise from their use. The following safety precautions must be observed in order to reduce the risk of injury, electric shocks, fire or damage to the equipment: Do not change or modify the system or add any equipment without the prior consent of the manufacturer. Only use original parts. These comply with the technical requirements specified by the manufacturer. The installation, operation and maintenance of the VISY-Command GUI and VISY-View Touch with VISY-SoftView software must be carried out by expert personnel only. Operators, fitters and service technicians must observe all applicable safety regulations. This also applies to any local safety and accident prevention regulations which are not stated in these operating instructions. The following safety information must be observed: The touchscreen must be operated only by finger or by means of a stylus designed for this purpose. The use of pointed objects (e.g. screwdrivers, pens) may cause damage to the touch screen. Useful information: Useful tips and information in this manual that should be observed are written in italics and identified by this symbol. Overview Page 2/48

6 2 Module description The VISY-SoftView software consists of the following modules: VISY-SoftView Starter VISY-SoftView Both software components are described in the sections below. 3 VISY-SoftView Starter The VISY-SoftView Starter module is launched automatically by the display module's operating system and has two tasks. Start phase During the start phase, the user is informed that the VISY-SoftView main application is starting up. The start process is shown by a progress bar. The start phase lasts approximately 30 seconds. Figure 1: VISY-SoftView Starter As soon as the VISY-SoftView main application has been fully loaded and the main screen is displayed, the starter application closes its window and begins to run as a background service. Background service VISY-SoftView Starter runs as a control instance in the background and monitors the VISY-SoftView main module. Page 3/48 VISY-SoftView Starter

7 4 VISY-SoftView The module VISY-SoftView is a display and report program for displaying tank information of the VISY-X system. All VISY-SoftView functions are accessible using the touchscreen interface. Individual functions of the main screen can be password-protected, see chapter "Password", VISY-SoftView Administrator, art. no VISY-SoftView Page 4/48

8 4.1 Main screen in the standard mode The following diagram shows a typical example of the main screen in the standard mode with 5 tanks and 1 oil separator (OS). The most important functions can be selected directly using the function keys on the main screen. The display of the main screen depends on the configuration. Figure 2 shows an example in "Standard" mode; figure 3 shows an example in "TD Display" mode (Tank Driver display). The Work mode is set in the menu "Reports and Configuration". Date and time System messages FAFNIR logo Tank display Oil Separator 1 Ullage: 496 L Volume: 504 L Reports and configuration Alarms Environmental sensors Tanks Print Home Figure 2: Main screen - Standard mode with oil separator activated Page 5/48 VISY-SoftView

9 4.2 Main screen in the TD mode (Tank Driver mode) The graphic below shows a typical example of the main screen the TD mode. Date and time System messages FAFNIR logo Tank display Reports and configuration Alarms Figure 3: Main screen - TD mode Environmental sensors Tanks Print Home In the following chapters, the individual functions and views are described in detail: Date and time, system messages, and FAFNIR logo Tank display with tank details Reports and configuration (system functions) Alarms Environmental sensors Tanks Print and Home VISY-SoftView Page 6/48

10 4.3 Date and time Main screen -> Display panel for date and time This display panel shows the date and the time; the time displayed here is synchronised system-wide. As soon as you touch this field, all open windows close and the application returns to the main screen. 4.4 System messages Main screen -> Display field for system messages This display panel shows the system status, as well as instructions on the use of the main screen function keys. The system status relates to the communication between the display module and the evaluation unit. For example, System Status: OK will be displayed when conditions are normal. Touching this field closes all open windows automatically and the application returns to the main screen. 4.5 FAFNIR logo Main screen -> FAFNIR logo Pressing the FAFNIR logo button calls up the software version and contact information of the FAFNIR GmbH. Pressing the Close button closes the active window. Page 7/48 VISY-SoftView

11 4.6 Tank display The main screen displays the most important tank information: Tank number and product name Alarm (if active) Graphical representation of the tank content Ullage and volume display Figure 4: Single tank Tank number: Product: Alarm: Ullage: Volume: same as the probe terminal number of the VI card the product name configured for this tank currently active alarms for this tank available tank capacity for filling current product volume in this tank The display is continuously updated so that all measured values are currently displayed at all times. In this overview, the ullage and volume are displayed in whole litres. The size of the tank graphic depends on the quantity of tanks configured in VISY- Setup. Up to eight tanks can be shown simultaneously on the main screen. If more than eight tanks have been configured, the remaining tanks are shown on a second screen. To change to the next screen, select the "More tanks" function key. The product level is displayed in proportion to the measured filling level. Each product has its own colour assigned. Touching one of the tank graphics opens the Tank Details screen for this tank (see section below). VISY-SoftView Page 8/48

12 4.6.1 Tank details Main screen -> Tank Details After touching a tank (example: Tank 6) the screen appears with tank details. Figure 5: Tank Details The Tank Details screen is continuously updated and shows the current values of the tank selected. The Alarm, Deliveries, Print and Static Leak Detection function keys are associated with this tank. The Tank Details screen is subdivided into the following fields: Tank Graphics Tank Configuration Measurement Values Alarms Age of Data (wireless operation only) RF Field Strength (only for radio operation) RF Battery (only for radio operation) Function keys The individual subfields are explained in the sections that follow. Page 9/48 VISY-SoftView

13 Tank Graphics Displays the tank selected from the main screen, with tank number, product name and tank level. If an alarm is active for this tank, the tank graphic will show the text Alarm. Tank Configuration Display of the configuration values defined in VISY-Setup for this tank: Parameter Description Nominal volume (specified by the tank manufacturer) Capacity Nominal volume minus safety volume Safety volume Area of tank left unfilled for safety reasons (upper part of tank) Product Product name Comp. Temperature Compensation temperature Measurement Values As supplied by the evaluation unit: Parameter Description Volume Product volume, non-temperature-compensated Volume TC Product volume, temperature-compensated Ullage Free volume available for filling Level Product level in millimetres Temperature Product Temperature Water level Water level in millimetres Density Product density, non-temperature-compensated Density TC Product density, temperature-compensated Density Temp. Temperature in the density measurement section Sump density Density measured at tank bottom, non-temperature-compensated Sump density TC Density measured at the tank bottom, temperature-compensated Alarms The density display is configurable. See also chapter Density configuration. Currently active alarms are listed in the Alarm windows. Alarm type Alarm parameter Product Very high, high, low, very low Water Very high, high Probe Various probe alarms For instructions on how to configure the alarms, see: Technical Documentation VISY-Setup V4, art. no VISY-SoftView Page 10/48

14 Age of Data This data field is displayed in wireless operation only (VISY-RF wireless system). In wireless operation, the probe data are transmitted in intervals and signals may be affected by car or lorry traffic at the petrol station. For this reason, it is important to know the age of the measured values received. RF Field strength This data field is displayed in wireless operation only and is an indication of the reception field strength. RF Battery This data field is displayed in wireless operation only and is an indication of the transmitter's battery charge. Function keys Button Function Description Alarms Opens the Alarm reporting function for the tank selected (see the section below). Delivery Opens the Delivery reporting function for the tank selected (see the section below). Static Leak Detection Print Opens the "Static Leak Detection" reporting function for the tank selected (see the section below). Prints the values displayed on this page. Close Closes the current screen. Page 11/48 VISY-SoftView

15 4.7 Reports and Configuration (system functions) Main screen -> System functions Touching the System functions button opens the selection menu for additional functions: Deliveries Configuration Static Leak Detection Mode Oil separator (only visible when VISY-Stick is defined as OS) Clean (touch screen) Figure 6: System functions VISY-SoftView Page 12/48

16 Button Function Description Deliveries Opens the menu Deliveries. Configuration Opens the password protected menu Configuration Static Leak Detection Opens the report function Static Leak Detection Work Mode Switches between the Standard display and the TD display (tank driver display) Oil separator Clean Starts the operating state or the maintenance state of the oil separator and opens a corresponding message window. Activates the mode to clean the screen. Close Closes the current window. The individual functions are described in the sections that follow. Page 13/48 VISY-SoftView

17 4.7.1 Deliveries Main screen -> System functions -> Deliveries Reports and alerts can be sent via , if these functions have been configured in the configuration menu "SMTP Server" and "System Options". Selecting this function displays the deliveries of the current month. The month for which these entries are displayed is shown on the wide month button below the Deliveries header. Using the +/- arrow keys, the user can select a different month and then update the list field by pressing the "Month button". Figure 7: Delivery Function VISY-SoftView Page 14/48

18 Button Function Description Month selection, one month back Month selection, one month forward Month button, month selection, month confirmed. Month button, month selection, not confirmed yet Displays the entries for this month. One of the month selection buttons has been pressed. List entry selection, one line up Selects the entry in the line above the current position. List entry selection, one line down Selects the entry in the line below the current position. Details Opens the detailed view window for the entry selected. Print Prints the values displayed on this page. Close Closes the current screen. Page 15/48 VISY-SoftView

19 List field The list field displays the most important delivery parameters. Further details for each delivery entry can be called up by pressing the Details button. Figure 8: Delivery data, overview in list field Column Name Description Start date Start date & time of delivery Tank Probe terminal number / tank Product Product name configured for this tank TC Volume / Ltr. Delivered product volume in litres, temperature-compensated Volume/Ltr. Delivered product volume in litres, non-temperature-compensated The following values are logged for each delivery: Parameter Description Tank number Probe terminal number for this tank Product Product name configured for this tank Start date Start of delivery Stop date End of delivery Volume TC Temperature-compensated delivery volume Start Volume TC Temperature-compensated volume at the start of delivery Stop Volume TC Temperature-compensated volume at the end of delivery Volume Delivery volume (non-temperature-compensated) Start Volume Volume (non-temperature-compensated) at the start of delivery Stop Volume Volume (non-temperature-compensated) at the end of delivery Start Temperature Product temperature at the start of delivery Stop Temperature Product temperature at the end of delivery Diff. Temperature Temperature difference (stop value minus start value) Start Prod. Level Product level (mm) at the start of delivery Stop Prod. Level Product level (mm) at the end of delivery Diff. Prod. Level Product level difference (in mm, stop value minus start value) Water level Water level (mm) at the start of delivery Stop Water level Water level (mm) at the end of delivery Diff. Water level Water level difference (in mm, stop value minus start value) Only the temperature-compensated volume shows the TC suffix. Volumes that do not have the TC suffix are non-temperature-compensated values. VISY-SoftView Page 16/48

20 Delivery entry details window For clarity, only the most important parameters are displayed for a selection in the list field. The desired delivery entry can be selected using the up and down buttons. The selected entry/line is highlighted with a dark background. Pressing the Details button opens the Delivery details window. This window displays all available details for the delivery selected. Figure 9: Delivery Detail window Button Function Description Speed button "down" Speed button "up" Print Rapidly scrolls to the bottom half of the Delivery details window. Rapidly scrolls to the top half of the Delivery details window. Prints the values displayed on this page. Close Closes the current screen. Speed button: Due to limited space, not all delivery details can be shown in the details window at once. The speed button enables the user to view the other half of the list instantly. The scroll direction is indicated by the position of the dash (top/bottom). Whenever the speed button is pressed, the symbol changes to represent the opposite direction. Page 17/48 VISY-SoftView

21 4.7.2 Configuration Main screen -> System functions -> Configuration Touching the Configuration button opens the configuration menu. For security, the functions available here are password-protected. To configure VISY-SoftView, see the Technical Documentation: VISY-SoftView Administrator, art. no VISY-SoftView Page 18/48

22 4.7.3 Static Leak Detection (report function all tanks) Main screen -> System functions -> Static Leak Detection Selecting this function displays the Static Leak Detection (SLD) entries for the current month. The month for which these entries are displayed is shown on the wide month button below the Static Leak Detection header. Using the +/- arrow keys, the user can select a different month and then update the list field by pressing the "Month button". Figure 10: Static Leak Detection For each SLD entry the most important parameters are displayed in this table: Start date Tank number Product name Start Volume TC (= temperature-compensated product volume) Difference (= Stop Volume TC minus Start Volume TC) Page 19/48 VISY-SoftView

23 Static Leak Detection, function keys Button Function Description Month selection, one month back Month selection, one month forward Month button, month selection, month confirmed Month button, month selection, not yet confirmed Displays the entries for this month. One of the month selection buttons has been pressed. List entry selection, one line up Selects the entry in the line above the current position. List entry selection, one line down Selects the entry in the line below the current position. Details Opens the detailed view window for the entry selected. Print Prints the values displayed on this page. Close Closes the current screen. VISY-SoftView Page 20/48

24 List field, Static Leak Detection (SLD) The list filed displays the most important SLD parameters. Further details of each SLD entry can be recalled by pressing the Details button. Figure 11: Static Leak Detection, overview in the list field Column Name Start date Tk Product Start Vol.TC/Ltr. Difference/Ltr. Description Start date & time of the Static Leak Detection (= SLD) Probe terminal number / tank Product name configured for this tank Product volume in litres, temperature compensated, at the start time Differences of the product volumes in litres, temperaturecompensated (end value minus start value) The following values are logged for each entry: Parameter Description Tank number Probe terminal number for this tank Product The product name configured for this tank Start date Start of SLD Stop date End of SLD Duration Time duration of the SLD Diff. Volume TC Difference of temperature compensated (=TC) volume Start Volume TC Temperature-compensated volume at the start of SLD Stop Volume TC Temperature-compensated volume at the end of SLD Diff. Prod. Level Product level difference (in mm, stop value minus start value) Start Prod. Level Product level (mm) at the start of SLD Stop Prod. Level Product level (mm) at the end of SLD Diff. Temperature Temperature difference (stop value minus start value) Start Temperature Product temperature at the start of SLD Stop Temperature Product temperature at the end of SLD Diff. Water level Water level difference (in mm, stop value minus start value) Water level Water level (mm) at the start of SLD Stop Water level Water level (mm) at the end of SLD Page 21/48 VISY-SoftView

25 Detail view More details can be displayed by pressing the "Details" button or by a "double-click" on the corresponding SLD Entry. Display of detailed information of the selected SLD entry Figure 12: Static Leak Detection, Details Button Function Description Speed button "down" Rapidly scrolls to the bottom half of the Delivery details window. Speed button "up" Rapidly scrolls to the top half of the SLD details window. Print Prints the values displayed on this page. Close Closes the current screen. Speed button: Due to limited space, not all SLD entry details can be shown in the details window at once. The speed button enables the user to view the other half of the list instantly. The scroll direction is indicated by the position of the dash (top/bottom). Whenever the speed button is pressed, the symbol changes to represent the opposite direction. VISY-SoftView Page 22/48

26 Print, Details Stat.Leak Detect. 18/07/ :12 Tank 3 Diesel Start Date: 18/07/ :20:37 End-date: 18/07/ :21:28 Duration: 02:00:51 Diff.Vol.TC: 0.0 Litres Start Vol.TC: Litres Stop Vol.TC: Litres Diff.Prod.Level: 0.0 mm Start Prod.Level: mm Stop Prod.Level: mm Diff.Temperature: 0.0 C Start Temperature: 13.8 C Stop Temperature: 13.8 C Diff.Water Level: 0.0 mm Start Water Level: 0.0 mm Stop Water Level: 0.0 mm Display of unfinished SLD For unfinished SLD currently no stop-values exist; then the corresponding values are displayed with "- -"; in the line "Duration" this fact is displayed or printed with "Test in progress". Figure 13: Static Leak Detection, not completed Page 23/48 VISY-SoftView

27 4.7.4 Static Leak Detection (report function individual tank) 1. Call up from "Tank Details" view In the "Tank-details" view the SLD report can be selected for the displayed tank. Figure 14: Static Leak Detection, call up of individual tank The call up of the SLD report here is for the selected tank; in the SLD report entries of this tank are listed only. VISY-SoftView Page 24/48

28 2. SLD Report function individual tank Figure 15: Static Leak Detection, list field individual tank More details for the selected entry can be displayed using the "details" button: Detail view Figure 16: Static Leak Detection, Details Page 25/48 VISY-SoftView

29 Print SLD Details, individual tank SLD, finished: Stat.Leak Detection 18/07/ :37 Tank 2 Super Start Date: 18/07/ :20:37 End-date: 18/07/ :21:28 Duration: 02:00:51 Diff.Vol.TC: Litres Start Vol.TC: Litres Stop Vol.TC: Litres Diff.Prod.Level: mm Start Prod.Level: mm Stop Prod.Level: mm Diff.Temperature: 0.0 C Start Temperature: 12.8 C Stop Temperature: 12.8 C Diff.Water Level: 0.0 mm Start Water Level: 0.0 mm Stop Water Level: 0.0 mm SLD, running test: Stat.Leak Detection 19/07/ :07 Tank 1 Benzin Start Date: 19/07/ :05:59 End-date: Test is running Duration: --:--:-- Diff.Vol.TC: -,- Litres Start Vol.TC: Litres Stop Vol.TC: -,- Litres Diff.Prod.Level: -,- mm Start Prod.Level: mm Stop Prod.Level: -,- mm Diff.Temperature: -,- C Start Temperature: 11.8 C Stop Temperature: -,- C Diff.Water Level: -,- mm Start Water Level: 0.0 mm Stop Water Level: -,- mm VISY-SoftView Page 26/48

30 4.7.5 Work Mode Main screen -> System functions -> Work Mode With the "Work mode" button, the Standard display or the TD Display (tank driver display) can be selected. The selection appears in the following windows in plain text. After pressing the Enter button, the window closes. Figure 17: System Functions - Mode of confirmation Page 27/48 VISY-SoftView

31 4.7.6 Oil separator Oil layer VISY-Stick probe with separation layer float Inlet Auto closure with float Outlet (at maximum fill level) Sludge trap Water layer Oil Separator Figure 18: Oil separator with VISY-Stick probe For details about the Oil Separator see Technical Documentation: VISY-SoftView Oil Separator, art. no Operating state Main screen -> System functions -> Oil separator (operating state) The graph shows an OS in use. The square (black) symbolically points to the "STOP" function that will be executed by pressing the button and that starts the maintenance state of the oil separator. The change from the operating to the maintenance state is reported to the user and it is pointed to the impact with respect to OS alarms. If the time monitoring of maintenance state is enabled, it is pointed to the automatic termination (here: time out in 8 hours) Figure 19: Message when activating the maintenance state VISY-SoftView Page 28/48

32 Maintenance State Main screen -> System functions -> Oil separator (maintenance state) The graph shows a cleaned OS. The triangle (green) symbolically points to the "START" function that will be executed by pressing the button and that stops the maintenance state of the oil separator. After that, the oil separator is in operation again. The change from the maintenance to the operating state is reported to the user. Figure 20: Message when finishing the maintenance state Page 29/48 VISY-SoftView

33 4.7.7 Screen Cleaning Main screen -> System functions -> Configuration -> Clean This function enables the cleaning of the touch screen for a particular time (approx. 15 seconds). Figure 21: Touch screen cleaning mode, display of remaining time During the cleaning period, a seconds counter counts down until a final message appears ("Goodbye"). During the cleaning period, the screen can be cleaned without unintentionally triggering any other functions. VISY-SoftView Page 30/48

34 4.8 Alarms Reports and alarms can be sent via , if these functions have been configured in the configuration menu "SMTP Server" and "System Options", see Technical Documentation: VISY-SoftView Administrator, art. no New alarms New alarms are displayed in the alarm dialogue box and at the same time, an audible alarm signal is activated, the alarm light starts blinking and a printout is initiated. The automatic printout of alarms can be configured. Figure 22: Acknowledgement of Alarms New alarms appear in the Alarm dialogue box and have to be confirmed. The button "Confirm" is effective for all alarms shown in the display window. Use the arrow keys to display a next group of alarms. After confirmation of the alarms, the acoustic signal is switched off, an automatic printout of acknowledged alarms starts and the displayed alarms are removed from the alarm dialogue box. Alarm Start 18/04/ :28 Tank 9 Diesel Alarm: Product low Start Date: :28: Automatic printout of a new alarm Page 31/48 VISY-SoftView

35 Alarm Confirmed :28 Tank 9 Diesel Alarm: Product low Start Date: :28:49 Confirmed: :28: Automatic printout of a confirmed alarm Alarm selection Main screen -> Alarm button The colour of the alarm button indicates whether alarms are present. When an alarm occurs, the lamp icon blinks red; otherwise a static blue alarm lamp is displayed. Pressing the alarm button calls up the dialogue window below, which enables the user to select the desired alarm source or to abort the process. The alarms are categorised by alarms of environmental sensors and alarms of tank probes. By a red underline the button indicates active alarms. Figure 23: Alarm selection Function key Environmental Tank probes Abort Description Displays the environmental alarm overview Displays the tank alarm overview Closes the dialogue window (returns to the main screen) VISY-SoftView Page 32/48

36 Tank alarms (Tank probes) Main screen -> Alarm key -> tank probes Selecting this function displays the tank alarms for the current month. The month for which these entries are displayed is shown on the wide month button below the Tank Alarms header. Using the +/- arrow keys, the user can select a different month and then update the list field by pressing the "Month button". Figure 24: Tank alarms overview Button Function Description Month selection, one month back Month selection, one month forward Month button, month selection, month confirmed Month button, month selection, not yet confirmed Displays the entries for this month. One of the month selection buttons has been pressed. Page 33/48 VISY-SoftView

37 Button Function Description List entry selection, one line up Selects the entry in the line above the current position. List entry selection, one line down Selects the entry in the line below the current position. Details Opens the detailed view window for the entry selected. Print Prints the values displayed on this page. Close Closes the current screen. List of tank alarms The list (see Figure 24 and Figure 25) shows the tank alarms along with their most important parameters. Further details for each alarm entry can be called up by pressing the Details button. Currently active alarms are displayed in red font on a yellow background. Previously active alarms are displayed in black font on a white background. Figure 25: List of tank alarms VISY-SoftView Page 34/48

38 Column Start date Tank Product Alarm type Description Time at start of alarm Tank (probe terminal number) for which the alarm was reported Product name configured for this tank Type of alarm reported, e.g. Product High The following values are logged for each tank alarm: Start date: Time at which the alarm occurred Confirmed: Time at which the alarm was acknowledged by the user Stop date: Time at which the cause of the alarm was rectified. Tank number: Tank (probe terminal) for which the alarm was reported Product: The product name configured for this tank Alarm: Alarm type, e.g. Product Low Alarm details (tank alarms) For selection in the list field, only the most important parameters are displayed. The desired alarm entry can be selected using the up and down buttons. Then this selected entry/line is highlighted with a dark background. Pressing the Details button opens the Alarm details window. This window displays all available details for the alarm selected. Figure 26: Alarm details window with currently active alarm Currently active alarms do not have a stop date entry. In this case, as shown in the example above, a hyphen - is displayed instead. Page 35/48 VISY-SoftView

39 Button Print Close Description Prints out the details displayed for the selected tank alarm entry. Closes the Tank Alarm Details window Environmental alarms (Environmental sensors) Main screen -> Alarms -> Environmental sensors Selecting this function displays the environmental alarms for the current month. The month for which these entries are displayed is shown on the wide month button below the Environmental alarms header. Using the +/- arrow keys, the user can select a different month and then update the list field by pressing the "Month button". Figure 27: Environmental alarms overview VISY-SoftView Page 36/48

40 Button Function Description Month selection, one month back Month selection, one month forward Month button, month selection, month confirmed Month button, month selection, not yet confirmed Displays the entries for this month. One of the month selection buttons has been pressed. List entry selection, one line up Selects the entry in the line above the current position. List entry selection, one line down Selects the entry in the line below the current position. Details Opens the detailed view window for the entry selected. Print Prints the values displayed on this page. Close Closes the current screen. Page 37/48 VISY-SoftView

41 List field (environmental alarms) The list field displays the most important alarm parameters. Further details of each alarm entry can be called up by pressing the Details button. Currently active alarms are displayed in red font on a yellow background. Previously active alarms are displayed in black font on a white background. Figure 28: List field with environmental sensor alarms Column Name Start date Device Description Time at start of alarm Name of the environmental sensor device for which the alarm was reported T. Probe terminal number Alarm type Type of alarm reported The following values are logged for each alarm: Start date: Time at which the alarm occurred Confirmed: Time at which the alarm was acknowledged by the user Stop date: Usually the time at which the cause of the alarm was rectified. Device: Device for which the alarm was reported Device-related additional information, e.g. pump-id for Dispenser Sump Probe terminal number ( T for Terminal ) Type of alarm (e.g. Probe not responding ) Alarm details (environmental alarms) For selection in the list field, only the most important parameters are displayed. The desired alarm entry can be selected using the up and down buttons. The selected entry/line is highlighted with a dark background. Pressing the Details button opens the Environmental Alarm details window. This window displays all available details for the alarm selected. VISY-SoftView Page 38/48

42 Figure 29: Environmental alarm details Button Print Close Description Prints out the details displayed for the selected environmental alarm entry. Closes the Environmental Alarm details window Page 39/48 VISY-SoftView

43 4.9 Environmental sensors Main screen -> Environmental sensors The environmental sensors are displayed as a hierarchy of three levels: Overview of all probes and device types Overview of a particular probe or device type Display of an individual probe or device All three views are described in detail in the sections that follow Overview of all probes and device types Main screen -> Environmental sensors button Pressing the Environmental sensors button calls up an overview of the selectable probe and device types. Figure 30: Environmental sensors, overview of probe/device types The colour mapping is: Green: No alarm present. Red: An alarm is present for one of the devices. Grey: No probe/device was configured yet. VISY-SoftView Page 40/48

44 When selecting a probe or device type all associated devices of the selected group are shown in a new window (see chapter Probes and devices of one type, Page 43). Designations For programming reasons, the designations of some environmental probes and devices have been abbreviated and may refer to one or more probes or devices. An overview is presented in the table below. Device (application) Designation, long Description Interstitial VISY-Stick/Reed Interstitial Object of measurement: Double-walled tanks Manhole sump Dispenser Sump VISY-Stick/Reed Sump Manhole VISY-Stick/Reed Sump Dispenser Object of measurement: Manhole sump Object of measurement: Dispenser Sump Oil separator Oil separator Oil separator sensors are connected to the VISY-Command with the VISY- Input 8 device. VISY Input VISY-Input 8 Digital 8-Channel Input Module VISY Output VISY-Output 8 8-Channel Relay Output Module LD Tank LD Product Pipe LD Delivery Pipe LD Manhole Sump Leak detection for tanks ("LD" = Leak Detection) Leak detection for product pipe Leak detection for filling pipe Leak detection for manhole sump Device for monitoring tank leakage. Connection to the VISY-Command with VISY-Input 8. Device for monitoring product pipe leakage (between tank and dispensers). Connection to the VISY-Command with VISY-Input 8. Device for monitoring filling pipe leakage (between connection fitting and tanks). Connection to the VISY-Command with VISY-Input 8. Device for monitoring manhole sump leakage. Connection to the VISY- Command with VISY-Input 8. Page 41/48 VISY-SoftView

45 Four examples are described here for the device type buttons: Button Function Description Probe type: Interstitial Device Type: Leak Detection manhole Probe type: Manhole sump (=Manhole sump) Device Type: VISY Output Alarms Button labelled with probe type. Background colour = green, i.e. (in the example) - Quantity of probes more than zero - No alarm reported Button labelled with device type. Background colour = green, i.e. (in the example) - Quantity of devices more than zero - No alarm reported Button labelled with probe type. Background colour = red, i.e. (in the example) - Quantity of probes more than zero - Alarm reported (by at least one probe) Button labelled with device type. Background colour = grey, i.e. (in the example). - No configured devices, i.e. no configured device of type VISY Output. Opens the alarm menu for the environmental sensors. Print Prints an overview. Close Closes the current window. The screen is continuously updated and reflects the current status of the probe/device types displayed. In the event of an alarm, it is possible to find and select the reporting device quickly as follows: The device type label is displayed with a red background. Pressing the red device type displays all individual devices (16) of the type selected (see example in the section below). The individual device that is reporting the alarm is displayed with a red background. Selecting the red device (i.e. pressing the button) then displays all available details for this device. VISY-SoftView Page 42/48

46 4.9.2 Probes and devices of one type Main screen -> Environmental Sensors -> single probe / device type By selection of a specific device type (in this example: "Interstitial") the entire devices of the selected type are displayed, here all of the 16 possible interstitial probes. The probes or devices are displayed as fields within the main screen. The function keys of the main screen are, therefore, still available, with the print and alarm functions relating to the probes or devices on display. Figure 31: Main screen showing probes/devices of the type selected For each individual probe or device, in this overview the following up-to-date information is displayed: Device/probe designation (here: "Interstitial") Number (1 to 16, quantity sometimes device-dependent) Configuration (Yes/No) Background colour: see below. Alarm condition (possible values: "OK", "alarm" or "-" The colour mapping is: Green: No alarm present. Red: An alarm is present for one of the devices. Grey: It was not yet configured a probe/device, status is displayed as "-". Further information may be available, depending on the device type: Page 43/48 VISY-SoftView

47 Pressing the button for an individual device opens a window showing further details for the device selected, e. g. active alarms (in plain text) and, where applicable, measured values (see next section). Three examples are described here for individual device buttons: Button Function Description Opens the details window of probe Interstitial no. 1 Opens the details window of probe Interstitial no. 4 Opens the details window of probe Interstitial no. 6 System functions Display of button labelled with probe type. Background colour = green, i.e. (in the example) Probe configured No alarm reported Display of button labelled with device type. Background colour = red, i.e. (in the example) Probe configured Alarm reported (at least one alarm) Display of button labelled with probe type. Background colour = grey, i.e. (in the example). Probe is not configured (not present), hence alarm status -. As on main screen, see next section: System functions. Alarms Opens the alarm menu, by default environmental sensor alarms. Environmental sensors Tanks As on main screen, see chapter Environmental sensors, returns to selection/overview of environmental probes / device types. As on main screen, see Tanks section, switches to tank information screen. Print Home Prints out an overview of all configured devices for the type displayed here (in this example: for the Interstitial probes). As on main screen, see Home button section. The screen is continuously updated and reflects the current status of the probes/devices displayed. VISY-SoftView Page 44/48

48 4.9.3 Individual probe or individual device Main screen -> Environmental sensors -> Probe/device type -> individual probe/device Pressing the button for a particular probe or device opens the details window for this probe or device. In the example below, the button for probe Interstitial 4 has been pressed. Figure 32: Details window for Interstitial 4 probe with alarm status The details window shows the available information for the device selected. The window is continuously updated. The following details are displayed: Probe/device designation (here: "Interstitial") Probe/device number (here: "4") Configuration status (colour code: see previous section) Alarm status (here: "Alarm") Alarm box (in this case two alarms: "Probe, installation error" and "Product alarm") Measured values (here: "Filling level: mm") The alarm field indicates whether alarms are currently active: if no alarm is present (status = OK), the field is blank. Measurement values: displayed only if the probe or device supplies additional measured values. Not all environmental devices supply measured values. Page 45/48 VISY-SoftView

49 Button Function Description Alarms Opens the alarm menu, by default environmental sensor alarms. Print Close Prints the information shown in the window for the individual probe/device (in this example: for Interstitial probe 4). Closes the current window. Environmental 12/04/ :21 Interstitial 4 Status: Alarm Alarms: Probe, installation error Product alarm Level: mm Figure 33: Printout of environmental sensor from details window of Interstitial 4 If VISY-Stick probes are configured as oil separators, they are shown as part of the environmental sensors with oil layer level (mm) and volume (litres). The status bar shows the function of the OS: Operating (OK) or in the maintenance state (OK - Maintenance) Figure 34: VISY-Stick-based Oil separator VISY-SoftView Page 46/48

50 4.10 Tanks Main screen -> Tanks button The main screen of VISY-SoftView shows up to eight (8) tanks. If there are more than 8 tanks in the system, they are displayed on additional pages. It is possible to move to the next page by pressing the Tanks button. Pressing the Tanks button calls up the tanks window if previously the environmental sensor window was displayed Print Main screen -> Print button Pressing the Print button prints off a summary of the tank or environmental sensor information displayed on the main screen. Tank data :32 Tk Capacity Ullage Volume ( L) ( L) ( L) 1: : : : : : Alarm state :32 1: OK 2: OK 3: OK 4: OK 5: Alarm 6: Alarm Environmental 30/03/ :40 Interstitial No. Status 1: OK 2: OK 3: Alarm 4: Alarm 5: OK 10: OK 11: OK 16: OK Figure 35: Printouts of the tank overview and of the environmental sensors 4.12 Home button Main screen -> Home button The Home button acts as a "Parking position" when system functions are closed. This prevents unintended opening of other functions. Page 47/48 List of figures

51 5 List of figures Figure 1: VISY-SoftView Starter... 3 Figure 2: Main screen - Standard mode with oil separator activated... 5 Figure 3: Main screen - TD mode... 6 Figure 4: Single tank... 8 Figure 5: Tank Details... 9 Figure 6: System functions Figure 7: Delivery Function Figure 8: Delivery data, overview in list field Figure 9: Delivery Detail window Figure 10: Static Leak Detection Figure 11: Static Leak Detection, overview in the list field Figure 12: Static Leak Detection, Details Figure 13: Static Leak Detection, not completed Figure 14: Static Leak Detection, call up of individual tank Figure 15: Static Leak Detection, list field individual tank Figure 16: Static Leak Detection, Details Figure 17: System Functions - Mode of confirmation Figure 18: Oil separator with VISY-Stick probe Figure 19: Message when activating the maintenance state Figure 20: Message when finishing the maintenance state Figure 21: Touch screen cleaning mode, display of remaining time Figure 22: Acknowledgement of Alarms Figure 23: Alarm selection Figure 24: Tank alarms overview Figure 25: List of tank alarms Figure 26: Alarm details window with currently active alarm Figure 27: Environmental alarms overview Figure 28: List field with environmental sensor alarms Figure 29: Environmental alarm details Figure 30: Environmental sensors, overview of probe/device types Figure 31: Main screen showing probes/devices of the type selected Figure 32: Details window for Interstitial 4 probe with alarm status Figure 33: Printout of environmental sensor from details window of Interstitial Figure 34: VISY-Stick-based Oil separator Figure 35: Printouts of the tank overview and of the environmental sensors List of figures Page 48/48

52 FAFNIR GmbH Bahrenfelder Str Hamburg, Germany Tel.: +49 / 40 / Fax: +49 / 40 / info@fafnir.com Web:

Trident User s Manual

Trident User s Manual Labkotec Oy Myllyhaantie 6 33960 Pirkkala FINLAND Tel. +358 (0)29 006 260 18.05.2017 Fax +358 (0)29 006 1260 Internet: www.labkotec.fi 34 pages Trident Copyright 2017 Labkotec Oy 1/34 TABLE OF CONTENTS

More information

The WAVE Plus Instant Notification System for Schools and Colleges

The WAVE Plus Instant Notification System for Schools and Colleges Instant Notification System for Schools and Colleges Duress alarm has been activated in the School of Engineering! Schools strive to provide a safe environment for students and teachers. In an emergency,

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

Ontech GSM 9040/50. Reference Manual English -1 -

Ontech GSM 9040/50. Reference Manual English -1 - Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7

More information

HERCULES 6 GRAPHICS SYSTEM

HERCULES 6 GRAPHICS SYSTEM HERCULES 6 GRAPHICS SYSTEM USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web: www.protec.co.uk

More information

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel Manual# 1006494 User s Manual 200E Series DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel User's Manual Rev. 1.0 Marine Pro 200E Series ~~~ DCU 210E Diesel Engine Control Unit DCU 208E Diesel

More information

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel Manual# 1100334 User s Manual 200 Series DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel Rev. March 2012 User's Manual for the Marine Pro 200 Series ~~~ DCU 210 Diesel Engine Control Unit DCU

More information

Patriot Systems Limited

Patriot Systems Limited COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organization whose name is registered with

More information

Monitor Alarms and Events

Monitor Alarms and Events This chapter contains the following topics: What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Find and View Alarms, page 3 Set Alarm and Event Management Preferences,

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

Patriot Systems Limited

Patriot Systems Limited COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organisation whose name is registered with

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections. ISSUES ISSUE DATE RELEASED DETAILS OF CHANGE AUTHOR 4 Rev 2 September 2004 Changes for 4000 series. DB 4 Rev 3 April 2005 Screen shots updated and other minor changes K.Z. 4 Rev 4 September 2006 4 Rev

More information

Autoclave Operations Manual

Autoclave Operations Manual UNIVERSITY OF ILLINOIS AT URBANA/CHAMPAIGN - COMPOSITES MANUFACTURING LAB Autoclave Operations Manual Version 1 Written by KRH 2/21/2011 Contents ACCS... 4 Alarms... 7 Main Display Tabs... 7 Process Control

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

Setting up and Managing Alarms in McAfee ESM 10.x

Setting up and Managing Alarms in McAfee ESM 10.x McAfee SIEM Alarms Setting up and Managing Alarms in McAfee ESM 10.x Introduction McAfee SIEM provides the ability to send alarms on a multitude of conditions. These alarms allow for users to be notified

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

HOA Annunciator Load Programming and Monitoring Instructions

HOA Annunciator Load Programming and Monitoring Instructions HOA Annunciator Load Programming and Monitoring Instructions Overview HOA Annunciator loads can be created in the ESS32 Load Directory for Novar s Savvy. Because the annunciator is built into the Savvy,

More information

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms 9 Defining Alarm Conditions Database-Generated Alarms The LookoutDirect alarm service keeps track of error messages and any process elements you have defined alarm conditions for. You can define alarm

More information

Simplex Panel Interface Guide

Simplex Panel Interface Guide Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.

More information

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A i.c³ User Guide For Helmer i.series Ultra-Low Freezers 360175-A/A Document History Revision Date CO Supersession Revision Description A 18 APR 2014* 9275 n/a Initial release. * Date submitted or change

More information

3D_ISS. Integrated Software System. User Guide Manual

3D_ISS. Integrated Software System. User Guide Manual 3D Digital Design & Development LTD 58/60 Edward Road Tribec House New Barnet EN4 8AZ 020 8440 7060 3D_ISS Integrated Software System User Guide Manual Copyright 2014 3D Digital Design and Development

More information

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A DS1067-062C Mod. 1067 LBT20063 REMOTE CONTROLLABLE ALARM CONTROL PANELS Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A USER MANUAL TABLE OF CONTENTS INTRODUCTION... 6 1 CONTROL DEVICES... 7 1.1 1067/022 keypad

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that

More information

FiRe mobile-2 Operation Manual

FiRe mobile-2 Operation Manual FiRe mobile-2 Operation Manual P/N 00-3230-505-0003-01 ISS 07JAN15 Copyright Trademarks and patents Manufacturer Version 2015 UTC Fire & Security. All rights reserved. The FiRe mobile-2 name and logo are

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9 Alarm Client Installation and User Guide NEC NEC Corporation May 2009 NDA-30364, Revision 9 Liability Disclaimer NEC Corporation reserves the right to change the specifications, functions, or features,

More information

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3 Manual# 1100268 User s Manual DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3 Table of Content GENERAL INFORMATION... 3 ABOUT THIS MANUAL... 3 400 SERIES OVERVIEW... 3 Available Modules...

More information

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7. BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.3, October 2017 Copyright 2017 BlackBerry Limited. All Rights Reserved.

More information

Monitor Alarms and Events

Monitor Alarms and Events What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Which Events Are Supported?, page 5 Set Alarm and Event Management Preferences, page 5 Interpret Event and Alarm

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations

More information

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D ASCO 5350 The ASCO 5350 ATS Remote Annunciator is listed under the Underwriter s Laboratories Standard UL-1008 for Automatic Transfer Switch accessories. This stand-alone device provides individual status

More information

LineGuard 2300 Program User Manual (FloBoss 107)

LineGuard 2300 Program User Manual (FloBoss 107) Form A6251 Part Number D301346X012 November 2012 LineGuard 2300 Program User Manual (FloBoss 107) Remote Automation Solutions Revision Tracking Sheet November 2012 This manual may be revised periodically

More information

WatchDog Wireless Crop Monitor Operation Manual

WatchDog Wireless Crop Monitor Operation Manual WatchDog Wireless Crop Monitor Operation Manual Spectrum Technologies, Inc. CONTENTS General Overview 3 Accessories 4 System Configuration 5 Configuring the Monitoring Unit 7 Powering Up the Unit 7 LED

More information

DELOMATIC 400, DM-400 HYDRO

DELOMATIC 400, DM-400 HYDRO Delomatic 400 HYDRO controller OPERATOR S MANUAL DELOMATIC 400, DM-400 HYDRO Functional description User interface Log books Alarm handling Document no.: 4189340880A SW version 1.0 or later Table of contents

More information

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list OPERATOR'S MANUAL Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax:

More information

AK-CS On Board Guide

AK-CS On Board Guide MAKING MODERN LIVING POSSIBLE AK-CS On Board Guide electronic controls & sensors About this guide The AK-CS On Board guide highlights the use of the RMT tool, allowing remote software management. Consult

More information

Yokogawa DX Ethernet Driver Help Kepware Technologies

Yokogawa DX Ethernet Driver Help Kepware Technologies Yokogawa DX Ethernet Driver Help 2012 Kepware Technologies 2 Table of Contents Table of Contents 2 4 Overview 4 Device Setup 5 Communications Parameters 7 Optimizing Your Ethernet Communications 9 Data

More information

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET Model: MM7100-2D Index Introduction 1 PC Setup 2-3 Bluetooth Setup 4-5 Discovery 6 USB Setup for USB instruments 7 Setting Instrument Parameters

More information

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL Advanced Gen-set Controller OPERATOR S MANUAL Display readings Push-button functions Alarm handling Log list Document no.: 4189340607A SW version 3.5X.X or later Table of contents 1. ABOUT THIS DOCUMENT...3

More information

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010 Procidia iware AlarmWorX32 AlarmWorX32 Viewer Siemens Protection AG 2008. notice All / Copyright rights reserved. notice Introduction / Contents Procidia iware is an operator interface software designed

More information

PageOne 2-way Pager Assured 2-way messaging for critical communications

PageOne 2-way Pager Assured 2-way messaging for critical communications Operating instructions PageOne 2-way Pager Assured 2-way messaging for critical communications www.pageonepager.com Contents Foreword......................................................... 3 Getting

More information

IndigoVision Alarm Panel. User Guide

IndigoVision Alarm Panel. User Guide IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE

More information

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown] OPERATING MANUAL PCC Controller (PCC-01 and 1-149160G) [PCC-01 shown] www.unipowerco.com 2018 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com

More information

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1 ViewMatrix Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels Version: 2.0 Revision: 0.1 CONTENTS 1. Introduction...3 2. Keyboard...5 2.1 POWER indication - Normal Operation...5

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3 Configuration Instruction Integration of IPS Video Analytics on Axis Cameras with a Milestone XProtect Video Management System Contents 1 Introduction... 1 2 Data transmission... 2 3 Compatibility... 3

More information

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger USER MANUAL USB Multi Function Dataloggers RHT30 Humidity/Temperature Datalogger TH30 Dual Temperature Datalogger Additional User Manual Translations available at www.extech.com Introduction Thank you

More information

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor with internal sensor OPERATION MANUAL ENGLISH PAGE -36 MODE D EMPLOI FRANAIS PAGE 37-7 ontent Page ) Display explanations 3 2) State of delivery / Sleep Mode 4 3) Gathering information prior to device

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide IndigoVision GAI-Tronics Integration Module Administrator's Guide GAI-Tronics Integration Module THIS MANUAL WAS CREATED ON 10 APRIL 2013. DOCUMENT ID: IU-IM-MAN019-1 Legal Considerations LAWS THAT CAN

More information

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center 5 System Integration Guide Avigilon Control Center 5 System Integration Guide for Paxton Net2 Access Control Systems 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted with

More information

Oracle Communications Performance Intelligence Center

Oracle Communications Performance Intelligence Center Oracle Communications Performance Intelligence Center System Alarms Guide Release 10.2.1 E77506-01 June 2017 1 Oracle Communications Performance Intelligence Center System Alarms Guide, Release 10.2.1

More information

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING Tempered Water Logic Control OPERATION l TROUBLE SHOOTING English For MPE Multiple Chiller Units Control Panel TEMPERED WATER SYSTEMS L-2199 Rev. 20080223 Revision: L-2199 20101104 *** IMPORTANT NOTICE

More information

MPL3115A2 Sensor Toolbox User s Guide

MPL3115A2 Sensor Toolbox User s Guide Freescale Semiconductor Document Number: MPL3115A2STUG User s Guide Rev. 0, 04/2012 MPL3115A2 Sensor Toolbox User s Guide 1 Introduction The Freescale DEMOSTBMPL3115A2 Sensor Toolbox provides the hardware

More information

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor with external sensor OPERATION MANUAL ENGLISH PAGE -35 GEBRAUHSANWEISUNG DEUTSH SEITE 36-70 ontent Page ) Display explanations 3 2) State of delivery / Sleep Mode 4 3) Gathering information prior to device

More information

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite Preliminary Revision: 1.0 Date: 12/4/2012 Revision: 1.0 Page i OmniSite Table of Contents Table of Contents... ii Revision History... iii Notice...iv Warning...iv Limited Warranty...iv Contact Information...iv

More information

the Comprehensive Control Solution

the Comprehensive Control Solution the Comprehensive Control Solution MANAGER MANUAL This manual contains user instructions for ITGuard, which is designed with focus on the comprehensive control of data centers and facilities. USER PRECAUTIONS

More information

I/A Series A 2 Software FoxAlert Alarm Manager

I/A Series A 2 Software FoxAlert Alarm Manager Product Specifications I/A Series A 2 Software FoxAlert Alarm Manager PSS 21S-2B2 B4 Current Alarms Display Most Recent Alarms Display Summary Displays By Status Alarm History Display An Extensive Collection

More information

FCD-wire Contents. List of Figures

FCD-wire Contents. List of Figures FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface

More information

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor with internal sensor OPERATION MANUAL ENGLISH PAGE -36 GEBRAUHSANWEISUNG DEUTSH SEITE 37-7 ontent Page ) Display explanations 3 2) State of delivery / Sleep Mode 4 3) Gathering information prior to device

More information

HEGA Ethernet Gateway Browser Interface Guide

HEGA Ethernet Gateway Browser Interface Guide HEGA Ethernet Gateway Web Interface HEGA Ethernet Gateway Browser Interface Guide Table of Contents Introduction: Browser Interface Guide 3 Common Tasks: 4 Check-in Reports 5 Check-in Administration 5

More information

Platinum Touch/Rotem One Touch

Platinum Touch/Rotem One Touch User Manual Platinum Touch / Rotem One Touch Platinum Touch/Rotem One Touch Climate Controllers Ag/MIS/UmGB-2583-05/18 Rev 1.0 P/N: 116556 Platinum Touch/Rotem One Touch User Manual Revision: N.1.0 of

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Velocity INT-HIRSCH-A-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation of this

More information

VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL. for. TLS-300 and TLS-350 UST Monitoring Systems. and

VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL. for. TLS-300 and TLS-350 UST Monitoring Systems. and VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL for TLS-300 and TLS-350 UST Monitoring Systems and TLS-350R Environmental & Inventory Management System through Software Versions 15/115 Manual Number

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document 70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,

More information

i-vu CCN 4.0 Owner s Guide

i-vu CCN 4.0 Owner s Guide i-vu CCN 4.0 Owner s Guide CARRIER CORPORAION 2007 A member of the United echnologies Corporation family. Stock symbol UX. 11-808-377-01 07/07 able of Contents ACCESSING YOUR SYSEM... 3 YOUR SYSEM DEAILS...

More information

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Centroid Snet 2 Battery Management Software User Manual V1.1 www.eepowersolutions.com Tel: 1-877-805-3377 info@eepowersolutions.com

More information

INTRODUCTION... VI I. IOS... 1

INTRODUCTION... VI I. IOS... 1 Contents INTRODUCTION... VI PURPOSE... VI KEY FUNCTIONS OF THE SYSTEM... VI TERMS AND ABBREVIATIONS... VII SMART HEATER APPLICATION:... X ios:... x Android:... x Windows:... x PRIVACY POLICY... XI ADAX

More information

INTRODUCTION... VI I. IOS... 1

INTRODUCTION... VI I. IOS... 1 Contents INTRODUCTION... VI PURPOSE... VI KEY FUNCTIONS OF THE SYSTEM... VI TERMS AND ABBREVIATIONS... VII SMART HEATER APPLICATION:... X ios:... x Android:... x Windows:... x PRIVACY POLICY... XI ADAX

More information

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Target Audience for this Document This document is aimed at system users and provides descriptions on how to install and maintain the Milestone

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Manage Alarms. Before You Begin CHAPTER

Manage Alarms. Before You Begin CHAPTER CHAPTER 8 Manage Alarms This chapter contains the procedures for viewing and managing the alarms and conditions on a Cisco ONS 15454. Cisco Transport Controller (CTC) detects and reports alarms generated

More information

RMS Monitoring Software System Startup

RMS Monitoring Software System Startup System Startup 2017 ROTRONIC AG Bassersdorf Switzerland 2017 ROTRONIC AG Bassersdorf Switzerland Page 2 of 53 Contents Contents... 3 1 Overview... 5 1.1 System Requirements... 5 1.1.1 Browser... 5 2 Create

More information

LMS-188-4P 4 POINT DIGITAL MONITOR/ALARM OPERATING INSTRUCTIONS

LMS-188-4P 4 POINT DIGITAL MONITOR/ALARM OPERATING INSTRUCTIONS G LMS 188 4P August, 2018 LMS-188-4P 4 POINT DIGITAL MONITOR/ALARM OPERATING INSTRUCTIONS! WARNING: This product can expose you to chemicals including lead, which is known to the State of California to

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

Fridge-tag 2 L. with external sensor OPERATION MANUAL

Fridge-tag 2 L. with external sensor OPERATION MANUAL Fridge-tag 2 L with external sensor OPERATION MANUAL Content ) Display explanations 3 2) State of delivery / Sleep Mode 4 3) Quality check prior to activation 4 4) Placing the sensor of the Fridge-tag

More information

CRIME. Manufacturing And Minor Inventions CRIME. Control Room Integrated Monitoring Environment

CRIME. Manufacturing And Minor Inventions CRIME. Control Room Integrated Monitoring Environment Control Room Integrated Monitoring Environment INDEX 1. Requirements for software. 2. Installation Instructions. 3. How to Register your Software. 4. Start Using... 5. Operating Instructions. 6. Screen

More information

Milestone XProtect Alarm Matrix Integration 1.0

Milestone XProtect Alarm Matrix Integration 1.0 Milestone XProtect Alarm Matrix Integration 1.0 Milestone XProtect Alarm Matrix Integration 1.0 Target Audience This document is aimed at system users and provides descriptions on how to install, configure

More information

Bosch TCU Integration Module Administrator's Guide

Bosch TCU Integration Module Administrator's Guide Bosch TCU Integration Module 1.0 - Administrator's Guide 10 Dec 2008 Rev 1.2 Table of Contents 1 Overview... 3 1.1 Compatibility...3 1.2 References...3 2 Installation... 4 3 Configuration... 5 3.1 System

More information

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD.

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD. 1 2 3 4 5 6 7 8 IN OFF ON + T S B J Т1 ocbridge Plus 1. FEATURES Wireless sensors receiver ocbridge is designated for connecting compatible Ajax devices to any third party wired central unit (panel) with

More information

Running IGSS as an Operator, Part One

Running IGSS as an Operator, Part One Running IGSS as an Operator, Part One Contents Duration We want to see how a completed IGSS SCADA system appears to plant operator personnel to get an idea of the various elements in the system and how

More information

Code Alert Series 30 Software User Guide

Code Alert Series 30 Software User Guide Code Alert Series 30 Software User Guide 2018 RF Technologies, Inc. All specifications subject to change without notice. All Rights Reserved. No Part of this work may be reproduced or copied in any form

More information

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer For the operator / for the heating engineer Operating and Installation Manual VRC 430f Weather compensator controller with radio transmission GB VRC 430f For the operator Operating instructions VRC 430f

More information

Section 9 System Operation

Section 9 System Operation Section 9 System Operation Operation of the control panel is simple. Menus guide you step-by-step through operations. This section of the manual is an overview of the operation menus. Please read this

More information

Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list OPERATOR'S MANUAL Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax:

More information

Follett Performance Plus

Follett Performance Plus Follett Performance Plus touchscreen user guide The next level of control in undercounter refrigeration Controller Operation - Performance Plus touchscreen Use and care of the LCD Performance Plus touchscreen

More information

EUROSCAN RX2-6 / TX2-6

EUROSCAN RX2-6 / TX2-6 Cabin and trailer recorder TABLE OF CONTENTS INTRODUCTION... 4 Data security... 4 Menu 1 Print menu... 6 1.1 Select compartment to print... 6 1.2 Time zone offset for printing... 6 1.3 Print event report...

More information

ZITON RADIO LOOP MODULE

ZITON RADIO LOOP MODULE ZITON RADIO LOOP MODULE PROGRAMMING MANUAL Table of Contents Section Page No 1.0 INTRODUCTION...3 1.1 System Design...3 1.2 Handling Precautions...3 1.3 Packaging:...3 2.0 MENU STRUCTURE...4 2.1 Menu Structure

More information

AS200 Wireless Alarm, Monitoring and Data Logging System USERS MANUAL

AS200 Wireless Alarm, Monitoring and Data Logging System USERS MANUAL ALARMING MITORING DATA LOGGING AS200 Wireless Alarm, Monitoring and Data Logging System USERS MANUAL Features Multi Function Alarm / Data Transmitter Multi Channel Receiver Range Increase Transceiver Internet

More information

Diagnostics and Monitoring System WEB Tool 2. User Manual

Diagnostics and Monitoring System WEB Tool 2. User Manual Diagnostics and Monitoring System 2 (Translation of the original documentation) User Manual S/N: Valid from: 01.05.2012 Rev.: 2.0 2 Rev. 1.... 1 1.1 General information... 1 1.1.1 Equipment... 1 1.1.2

More information

Dashboard for Windows V1.1.0

Dashboard for Windows V1.1.0 User manual Dashboard for Windows V1.1.0 TBS Electronics BV De Factorij 46 1689 AL Zwaag The Netherlands www.tbs-electronics.com COPYRIGHT 2009 (rev1e) - 1 - TABLE OF CONTENTS 1. INTRODUCTION......................

More information

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44 (0) 1282 717171 www.protec.co.uk

More information

Alarm Monitoring and Management

Alarm Monitoring and Management 14 CHAPTER This chapter explains how to manage alarms with Cisco Transport Controller (CTC). To troubleshoot specific alarms, refer to the Cisco ONS 15454 SDH Troubleshooting Guide. Chapter topics include:

More information

Using ANM Mobile CHAPTER

Using ANM Mobile CHAPTER CHAPTER 19 Date: 3/22/13 This chapter describes Cisco ANM Mobile, which allows you to access your ANM server or ANM Virtual Appliance and manage your devices using a mobile device such as an iphone or

More information