E5CN/E5CN-U (48 x 48 mm)

Size: px
Start display at page:

Download "E5CN/E5CN-U (48 x 48 mm)"

Transcription

1 Basic-type Digital Temperature Controller /-U (48 x 48 mm) New 48 x 48-mm Basic Temperature Controller with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function. Indication Accuracy Thermocouple input: ±.3% of PV (previous models: ±.5%) Pt input: ±.% of PV (previous models: ±.5%) Analog input: ±.% FS (previous models: ±.5%) New -U s (Plug-in s) with analog inputs and current outputs. A PV/SV-status display function can be set to automatically alternate between displaying the status of the Temperature Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV. Preventive maintenance for relays in the Temperature Controller using a Control Output / Counter mm mm -U Refer to Safety Precautions on page 66. -U (48 x 48 mm) -H (48 x 48 mm) Main I/O Functions Event Inputs Two Sensor Inputs Universal thermocouple/pt inputs (s with temperature inputs) Analog current/voltage inputs (s with analog inputs) Indication Accuracy Thermocouple input: ±.3% of PV Pt input: ±.% of PV Analog input: ±.% FS Sampling Period 5 ms Control Output Voltage output (for driving SSR) -level Display: PV and SV Control Output ong-life relay output (hybrid) Auxiliary Outputs One Two 4-digit Display Auto/manual switching Temperature Controller status display Simple program function Control output / count alarm PV change rate alarm s also available with communications Operation This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. /E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H6) /E5AN/E5EN Digital Temperature Controllers Manual Basic Type (Cat. No. H8) Safety Precautions 3

2 /-U ineup -U (48 x 48 mm) Terminal block Temperature input control output control outputs control output or auxiliary outputs auxiliary outputs or auxiliary outputs Basic Type Analog input control outputs auxiliary outputs -H (48 x 48 mm) Safety Precautions Operation Note: s with one control output and one or two auxiliary outputs and models with two control outputs can be used for heating/cooling control. Number Structure Number egend Controllers -@@M@@-@ Control Output R: Q: C: Y: ong-life relay output (hybrid). Auxiliary Outputs Blank: : Two outputs 3. Option M: Option Unit can be mounted. 4. Input Type T: Universal thermocouple/platinum resistance thermometer : Analog current/voltage input 5. Power Supply Voltage Blank: to 4 VAC D: 4 VAC/VDC 6. Case Color Blank: Black W: Silver 7. Terminal Cover -5: With terminal cover Plug-in Temperature input Analog input Option Units E53-CN@@@ 3 4. Applicable Controller CN: or -H control output control output. Function Blank: Q: Control output (voltage for driving SSR) P: Power supply for sensor,, or auxiliary outputs,, or auxiliary outputs 3. Function Blank: H: Heater burnout/ssr failure/heater overcurrent detection (CT) HH: Heater burnout/ssr failure/heater overcurrent detection (CT) B: Two event inputs 3: communications H3: Heater burnout/ssr failure/heater overcurrent detection (CT) communications HB: Heater burnout/ssr failure/heater overcurrent detection (CT) Two event inputs HH3: Heater burnout/ssr failure/heater overcurrent detection (CT) communications 4. Version N: Applicable only to models released after January 8 Note: Not all combinations of function and function specifications are possible for Option Units (E53-@@@@).. Always connect an AC load to a long-life relay output. The output will not turn if a DC load is connected because a triac is used for switching the circuit. For details, check the conditions in Ratings.. Auxiliary outputs are contact outputs that can be used to output alarms or results of logic operations. 4

3 Ordering Information Controllers with Terminal Blocks Size /6 DIN (W H D) Case color Black Power supply voltage to 4 VAC 4 VAC/VDC Option Units One of the following Option Units can be mounted to provide the with additional functions. Silver Note: Option Units cannot be used for plug-in models. These Option Units are applicable only to models released after January 8. /-U Input type Auxiliary outputs Control output Thermocouple or Resistance thermometer Thermocouple or Resistance thermometer to 4 VAC Analog (current/voltage) 4 VAC/VDC to 4 VAC Analog (current/voltage) Thermocouple or Resistance thermometer 4 VAC/VDC 3-phase heater burnout/ssr failure/ Heater overcurrent detection Heater burnout/ssr failure/heater overcurrent detection Heater burnout/ssr failure/heater overcurrent detection Heater burnout/ssr failure/heater overcurrent detection Heater burnout/ssr failure/heater overcurrent detection 3-phase heater burnout/ssr failure/ Heater overcurrent detection Functions Event inputs Event inputs Event inputs Event inputs Control output (Voltage for driving SSR) Control output (Voltage for driving SSR) Control output (Voltage for driving SSR) Control output (Voltage for driving SSR) ong-life relay output (hybrid) ong-life relay output (hybrid) ong-life relay output (hybrid) External power supply for ESB External power supply for ESB External power supply for ESB -RMT-5 -QMT-5 -CMT-5 -RMT-5 -QMT-5 -CMT-5 -YMT-5 -RMTD-5 -QMTD-5 -CMTD-5 -RMTD-5 -QMTD-5 -CMTD-5 -RM-5 -QM-5 -CM-5 -RM-5 -QM-5 -CM-5 -YM-5 -RMD-5 -QMD-5 -CMD-5 -RMT-W-5 -QMT-W-5 -CMT-W-5 -RMT-W-5 -QMT-W-5 -CMT-W-5 -YMT-W-5 -RMTD-W-5 -QMTD-W-5 -CMTD-W-5 E53-CNHH3N E53-CNHBN E53-CNQ3N E53-CNPBN E53-CNPHN E53-CNP3N E53-CNH3N E53-CN3N E53-CNBN E53-CNQHN E53-CNQHHN E53-CNQBN -U (48 x 48 mm) -H (48 x 48 mm) Operation Safety Precautions 5

4 -U (48 x 48 mm) -H (48 x 48 mm) Safety Precautions Operation /-U Number Structure Number egend (Plug-in-type Controllers) -@@@U 3 4. Output Type R: Q: C:. Number of Alarms Blank: No alarm : One alarm : Two alarms Ordering Information Plug-in-type Controllers 3. Input Type T: Universal thermocouple/platinum resistance thermometer : Analog Input 4. Plug-in type U: Plug-in type Size Case color Power supply voltage Input type Auxiliary outputs Control output /6 DIN Black to 4 VAC 4 VAC/VDC Thermocouple or resistance thermometer Analog (current/voltage) Thermocouple or resistance thermometer -RTU -QTU -CTU -RTU -QTU -CTU -RTU -QTU -CTU -RU -QU -CU -RU -QU -CU -RTDU -QTDU -CTDU -RTDU -QTDU -CTDU -RTDU -QTDU -CTDU 6

5 Accessories (Order Separately) USB-Serial Conversion Cable Terminal Cover Connectable models E58-CIFQ Terminal block models E53-COV7 Note: The Terminal Cover comes with the models. Waterproof Packing Y9S-9 Note: The Waterproof Packing is included with the Controller only for models with terminal blocks. Current Transformers (CTs) Hole diameter 5.8 dia. E54-CT. dia. E54-CT3 Adapter Connectable models Terminal block models /-U Note: Use this Adapter when the panel has been previously prepared for the Sockets (for Plug-in s) Type Front-connecting Socket Front-connecting Socket with Finger Protection Back-connecting Socket Terminal Cover for Back-connecting socket with Finger Protection C-Thermo Support Software EST-C-MV4 Y9F-45 PCF- PCF--E P3GA- Y9A-48G -U (48 x 48 mm) Safety Precautions Operation -H (48 x 48 mm) 7

6 -U (48 x 48 mm) -H (48 x 48 mm) Safety Precautions Operation /-U Specifications Ratings Power supply voltage Operating voltage range Power consumption Sensor input Input impedance Control method Control outputs Auxiliary outputs -U Voltage output (for driving SSR) No D in model number: to 4 VAC, 5/6 Hz D in model number: 4 VAC, 5/6 Hz; 4 VDC 85% to % of rated supply voltage to 4 VAC: 7.5 VA (max.) (-RT at VAC: 3. VA) 4 VAC/VDC: 5 VA/3 W (max.) (-RTD at 4 VAC:.7 VA) to 4 VAC: 6 VA (max.) 4 VAC/VDC: 3 VA/ W (max.) (models with current output: 4 VA/ W) s with temperature inputs Thermocouple: K, J, T, E,, U, N, R, S, B, W, or P II Platinum resistance thermometer: Pt or JPt Infrared temperature sensor: to 7 C, 6 to C, 5 to 65 C, or to 6 C Voltage input: to 5 mv s with analog inputs Current input: 4 to ma or to ma Voltage input: to 5 V, to 5 V, or to V Current input: Ω max., Voltage input: MΩ min. (Use a : connection when connecting the ES-HB.) / control or -PID control (with auto-tuning) -U -U ST-NO, 5 VAC, 3 A (resistive load), electrical life:, operations, minimum applicable load: 5 V, ma DT, 5 VAC, 3 A (resistive load), electrical life:, operations, minimum applicable load: 5 V, ma Output voltage: VDC ±% (PNP), max. load current: ma, with short-circuit protection circuit 4 to ma DC/ to ma DC, load: 6 Ω max., resolution: approx., ong-life relay output Number of outputs Output specifications ST-NO, 5 VAC, 3 A (resistive load), electrical life:,, operations, load power supply voltage: 75 to 5 VAC (DC loads cannot be connected.), minimum applicable load: 5 V, ma, leakage current: 5 ma max. (5 VAC, 6 Hz) or max. (Depends on the model.) : ST-NO, 5 VAC, 3 A (resistive load), electrical life:, operations, minimum applicable load: 5 V, ma Number of inputs Event External contact Contact input: : kω max., : kω min. inputs input specifications Non-contact input: : Residual voltage:.5 V max., : eakage current:. ma max. Current flow: Approx. 7 ma per contact External power supply for ESB VDC ±%, ma, short-circuit protection circuit provided Setting method Indication method Multi Bank switching Digital setting using front panel keys -segment digital display and individual indicators (7-segment display also possible) Character height: PV: mm, SV: 6.5 mm Up to four set points ( to 3) can be saved and selected using event inputs, key operations, or serial communications. Not supported Manual output, heating/cooling control, loop burnout alarm, ramp, other alarm functions, heater burnout detection, 4% AT, % AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, Other functions protection functions, control output / counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment Ambient operating temperature to 55 C (with no condensation or icing), for 3-year warranty: to 5 C Ambient operating humidity 5% to 85% Storage temperature 5 to 65 C (with no condensation or icing) 8

7 /-U Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal Inputs) Temperature range ( C) Input Type Platinum resistance thermometer s with Analog Inputs Shaded settings are the default settings. Thermocouple Name Pt JPt K J T E U N R S B W P II Setting number Infrared temperature sensor to 7 C 6 to C 5 to 65 C to 6 C Analog input to 5 mv -U (48 x 48 mm) -H (48 x 48 mm) Safety Precautions Operation Shaded settings are the default settings. The applicable standards for the input types are as follows: K, J, T, E, N, R, S, B: JIS C 6-995, IEC 584- : Fe-CuNi, DIN U: Cu-CuNi, DIN W: W5Re/W6Re, ASTM E Input Type Current Voltage Input specification 4 to ma to ma to 5 V to 5 V to V Setting range Usable in the following ranges by scaling: 999 to 9999, 99.9 to 999.9, 9.99 to or.999 to Setting number Usable in the following ranges by scaling: 999 to 9999 or 99.9 to JPt: JIS C , JIS C Pt: JIS C , IEC 75 P II: According to Platinel II electromotive force charts from BASF (previously Engelhard) 9

8 /-U -U (48 x 48 mm) -H (48 x 48 mm) Alarm Outputs Each alarm can be independently set to one of the following alarm types. The default is : Upper limit. Auxiliary outputs are allocated for alarms. delays and delays ( to 999 s) can also be specified. Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm will be an OR output of the alarm selected from the following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR failure alarm, and heater overcurrent alarm for alarm, set the alarm type to (i.e., no alarm function). Set value Alarm type Alarm function Upper- and lowerlimit Upper limit 3 ower limit Upper- and lowerlimit range Upper- and lowerlimit with standby sequence Upper-limit with standby sequence ower-limit with standby sequence Absolute-value upper-limit Absolute-value lower-limit Absolute-value upper-limit with standby sequence Absolute-value lower-limit with standby sequence BA (for alarm only) PV change rate alarm Alarm output operation When is positive Output H H H 3 4 When is negative. With set values, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as and H.. Set value:, Upper- and lower-limit alarm Case H H <, > H < Case H H >, < H > 3. Set value: 4, Upper- and lower-limit range Case H H <, > H < Case H H >, < H > Case 3 (Always ) 4. Set value: 5, Upper- and lower-limit with standby sequence For Upper- and ower-imit Alarm Described Above Case and Always when the upper-limit and lower-limit hysteresis overlaps. Case 3: Always 5. Set value: 5, Upper- and lower-limit with standby sequence Always when the upper-limit and lower-limit hysteresis overlaps. H H H Case 3 (Always ) H H H H <, < H <, > H H >, < H H <, < H <, > H H >, < H Safety Precautions Operation

9 /-U Characteristics Indication accuracy Influence of temperature Influence of voltage Input sampling period Hysteresis Thermocouple: Terminal block models (): (±.3% of indicated value or ± C, whichever is greater) ± digit max. Plug-in models (-U): (±% of indicated value or ± C, whichever is greater) ± digit max. Platinum resistance thermometer input: Terminal block models () and plug-in models (-U): (±.% of indicated value or ±.8 C, whichever is greater) ± digit max. Analog input: Terminal block models () and plug-in models (-U): ±.% FS ± digit max. CT input: Terminal block models (): ±5% FS ± digit max. Thermocouple input (R, S, B, W, P II): Terminal block models (): (±% of PV or ± C, whichever is greater) ± digit max. Plug-in models (-U): (±% of PV or ± C, whichever is greater) ± digit max. Other thermocouple input: 3 Terminal block models (): (±% of PV or ±4 C, whichever is greater) ± digit max. Plug-in models (-U): (±% of PV or ±4 C, whichever is greater) ± digit max. Platinum resistance thermometer input: Terminal block models () and plug-in models (-U): (±% of PV or ± C, whichever is greater) ± digit max. Analog input: Terminal block models () and plug-in models (-U): (±%FS) ± digit max. 5 ms s with thermocouple/platinum resistance thermometer input (universal input):. to EU (in units of. EU) 4 s with analog input:. to 99.99% FS (in units of.% FS) Proportional band (P) s with thermocouple/platinum resistance thermometer input (universal input):. to EU (in units of. EU) 4 s with analog input:. to 999.9% FS (in units of.% FS) Integral time (I) to 3999 s (in units of s) Derivative time (D) to 3999 s (in units of s) 5 Control period.5, to 99 s (in units of s) Manual reset value. to.% (in units of.%) Alarm setting range Affect of signal source resistance Insulation resistance Dielectric strength Vibration Malfunction resistance Destruction Shock Malfunction resistance Destruction Weight Degree of protection -U -U Memory protection Setup Tool Setup Tool port Standards EMC Approved standards 7 Conformed standards 999 to 9999 (decimal point position depends on input type) Thermocouple:. C/Ω max. ( Ω max.) Platinum resistance thermometer:. C/Ω max. ( Ω max.) MΩ min. (at 5 VDC),3 VAC, 5 or 6 Hz for min (between terminals with different charge) to 55 Hz, m/s for min each in, Y, and Z directions to 55 Hz,.75-mm single amplitude for hrs each in, Y, and Z directions m/s, 3 times each in, Y, and Z directions 3 m/s, 3 times each in, Y, and Z directions Controller: Approx. g, Mounting Bracket: Approx. g Controller: Approx. g, Mounting Bracket: Approx. g Front panel: IP66, Rear case: IP, Terminals: IP Front panel: IP5, Rear case: IP, Terminals: IP Non-volatile memory (number of writes:,, times) C-Thermo version 4. or higher Provided on the bottom of the. Use this port to connect a computer to the when using the Setup Tool. An E58-CIFQ USB-Serial Conversion Cable is required to connect the computer to the. 6 U 6-, CSA C. No. - EN 6- (IEC 6-): Pollution level, overcurrent category II EMI: EN 66 Radiated Interference Electromagnetic Field Strength: EN 55 Group, class A Noise Terminal Voltage: EN 55 Group, class A EMS: EN 66 ESD Immunity: EN 6-4- Electromagnetic Field Immunity: EN Burst Noise Immunity: EN Conducted Disturbance Immunity: EN Surge Immunity: EN Power Frequency Magnetic Field Immunity: EN Voltage Dip/Interrupting Immunity: EN The indication accuracy of K thermocouples in the to C range, T and N thermocouples at a temperature of C max., and U and thermocouples at any temperatures is ± C ± digit max. The indication accuracy of the B thermocouple at a temperature of 4 C max. is not specified. The indication accuracy of B thermocouples in the 4 to 8 C range is ±3 C max. The indication accuracy of the R and S thermocouples at a temperature of C max. is ±3 C ± digit max. The indication accuracy of W thermocouples is ±.3 of PV or ±3 C, whichever is greater, ± digit max. The indication accuracy of P II thermocouples is ±.3 of PV or ± C, whichever is greater, ± digit max.. Ambient temperature: C to 3 C to 55 C, Voltage range: % to % of rated voltage 3. K thermocouple at C max.: ± max. 4. EU stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is C or F. 5. When robust tuning (RT) is, the differential time is. to (in units of. s). 6. External communications () and cable communications for the Setup Tool can be used at the same time. 7. The -U plug-in model is certified for U listing only when used together with the OMR PCF- or PCF--E Socket. The P3GA- is not certified for U listing. -U (48 x 48 mm) -H (48 x 48 mm) Operation Safety Precautions

10 /-U -U (48 x 48 mm) -H (48 x 48 mm) Safety Precautions Operation USB-Serial Conversion Cable Applicable OS Applicable software Windows, P, or Vista Thermo Mini, C-Thermo version 4. or higher Applicable models E5AN/E5EN//-U/E5AN-H/ E5EN-H/-H USB interface standard Conforms to USB Specification.. DTE speed Connector specifications Power supply Power supply voltage Current consumption Ambient operating temperature Ambient operating humidity 384 bps Computer: USB (type A plug) Temperature Controller: Setup Tool port (on bottom of Controller) Bus power (Supplied from USB host controller.) 5 VDC 7 ma to 55 C (with no condensation or icing) % to 8% Storage temperature to 6 C (with no condensation or icing) Storage humidity % to 8% Altitude Weight Note: A driver must be installed in the personal computer. Refer to installation information in the operation manual for the Conversion Cable. Specifications Transmission line connection method Synchronization method Protocol Baud rate Transmission code Data bit length Stop bit length Error detection Flow control Interface Retry function buffer response wait time, m max. Approx. g : Multipoint (two-wire, half duplex) Start-stop synchronization CompoWay/F, SYSWAY, or Modbus, 4, 48, 96, 9, 384, or 576 bps ASCII 7 or 8 bits or bits Vertical parity (none, even, odd) Frame check sequence (FCS) with SYSWAY Block check character (BCC) with CompoWay/F or CRC-6 Modbus 7 bytes to 99 ms Default: ms The baud rate, data bit length, stop bit length, and vertical parity can be individually set using the Setting evel. Current Transformer (Order Separately) Ratings Dielectric strength, VAC for min Vibration resistance 5 Hz, 98 m/s Weight Accessories (E54-CT3 only) E54-CT: Approx..5 g, E54-CT3: Approx. 5 g Armatures () Plugs () Heater Burnout Alarms, SSR Failure Alarms, and Heater Overcurrent Alarms CT input (for heater current detection) Maximum heater current Input current indication accuracy Heater burnout alarm setting range SSR failure alarm setting range Heater overcurrent alarm setting range 3 s with detection for single-phase heaters: One input s with detection for single-phase or three-phase heaters: Two inputs 5 A AC ±5% FS ± digit max.. to 49.9 A (in units of. A) Minimum detection time: ms. to 49.9 A (in units of. A) Minimum detection time: ms. to 49.9 A (in units of. A) Minimum detection time: ms. For heater burnout alarms, the heater current will be measured when the control output is, and the output assigned to the alarm function will turn if the heater current is lower than the set value (i.e., heater burnout detection current value).. For SSR failure alarms, the heater current will be measured when the control output is, and the output assigned to the alarm function will turn if the heater current is higher than the set value (i.e., SSR failure detection current value). 3. For heater overcurrent alarms, the heater current will be measured when the control output is, and the output assigned to the alarm function will turn if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical ife Expectancy Curve for Relays (Reference Values) ife ( 4 operations) VAC, 3 VDC (resistive load) cosφ = Switching current (A) Note: Do not connect a DC load to a Controller with a ong-life Relay Output.

11 External Connections /-U A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect any of the control output terminals to ground. (If the control output terminals are connected to ground, errors will occur in the measured temperature values as a result of leakage current.) Consult with your OMR representative before using the external power supply for the ESB for any other purpose. Controllers -U (48 x 48 mm) Control output ong-life relay output 5 VAC, 3 A (resistive load) 5 VAC, 3 A (resistive load) VDC, ma to ma DC 4 to ma DC oad: 6 Ω max. Control output VDC, ma Option Units E53-CNHH3N () and CT B() A( ) CT CT E53-CNH3N () and CT B() A( ) DO NOT CT Control output DO NOT DO NOT A ma B V DO NOT B TC/Pt Analog input universalinput E53-CNHBN Event inputs and CT EV EV CT E53-CN3N () B() A( ) DO NOT DO NOT DO NOT E53-CNQ3N () and Control Output B() A( ) DO NOT Control output E53-CNBN Event inputs EV EV DO NOT DO NOT Auxiliary outputs (relay outputs) 5 VAC, 3 A (resistive load) Auxiliary outputs (relay outputs) Auxiliary output Auxiliary output Input power supply to 4 VAC 4 VAC/VDC (no polarity) E53-CNPBN Event Inputs and External Power Supply EV EV External power supply VDC, ma E53-CNQHN Control Output and CT Control output DO NOT CT E53-CNPHN External Power Supply and CT External power supply DO NOT CT A heater burnout alarm, heater short alarm, heater overcurrent alarm, or input alarm is sent to the output to which the alarm function is assigned. VDC, ma E53-CNQHHN Control Output and CT Control output CT CT E53-CNP3N () and External Power Supply B() A( ) DO NOT External VDC, power supply ma E53-CNQBN Event Inputs and Control Output EV EV Control output -H (48 x 48 mm) -U Control output Control output (three terminals used) DT, 5 VAC, 3 A (resistive load) DO NOT DO NOT A Voltage output ma (for driving SSR) B VDC, ma V DO NOT 4 to ma DC B to ma DC oad: 6 W max. Analog input TC/Pt universal input Note: For the Wiring Socket, purchase the PCF- or PG3A- separately. Auxiliary output 5 VAC, 3 A (resistive load) (s) Auxiliary output Auxiliary output (Control output (cooling side)) Input power supply to 4 VAC 4 VAC/VDC (no polarity) An input error is sent to the output to which the alarm function is assigned. Operation Safety Precautions

12 /-U Nomenclature -U (48 x 48 mm) -U The front panel is the same for the and -U. Operation indicators Temperature unit No. display No. display evel Key Up Key Dimensions Mode Key Down Key (Unit: mm) -H (48 x 48 mm) Terminal s -U Plug-in s Waterproof Mounting Adapter Packing (Accessory) (Accessory) Terminal Cover (E53-COV7) (Accessory) Panel Cutout Mounted Separately 6 min. Note: The terminal block cannot be removed. (84.7) Panel Cutout Mounted Separately Group Mounted (48 number of units.5). Group mounting does not allow waterproofing Recommended panel thickness is to 5 mm. Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.) To mount the Controller so that it is waterproof, insert the waterproof packing onto the Controller. When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. Group Mounted (48 number of units.5) Safety Precautions Operation Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ Mounting Adapter (Accessory) USB connector (type A plug) 6 min (,) 5 ED indicator (SD),765 ED indicator (RD) Recommended panel thickness is to 5 mm. Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.) When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. Serial connector

13 /-U Terminal Cover E53-COV Note: The E53-COV cannot be used. Waterproof Packing Y9S-9 (for DIN 48 48) Order the Waterproof Packing separately if it becomes lost or damaged. The Waterproof Packing can be used to achieve an IP66 degree of protection. (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the operating environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMR shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required. -U (48 x 48 mm) 9. Current Transformers E54-CT E54-CT dia..5 Two, 3.5 dia..36 dia. dia E54-CT Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current: 5 A (5/6 Hz) Number of windings: 4± Winding resistance: 8± Ω Output voltage (Eo) V (r.m.s.) V 5 Hz mv μv kω Ω R = Ω Distortion factor % 3% % -H (48 x 48 mm) ma, A 4 4 Thru-current (Io) A (r.m.s.) 3 Two, M3 (depth: 4) E54-CT3 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current: A (5/6 Hz) (Maximum continuous heater current for the Temperature Controller is 5 A.) Number of windings: 4± Winding resistance: 8±.8 Ω Operation E54-CT3 Accessory Armature Approx. 3 dia. Plug Approx. 6 dia. () 8 Connection Example Armature Plug ead Output voltage (Eo) V (r.m.s.) V 5 Hz mv μv kω 5 Ω Ω 5 Ω R = Ω Distortion factor % 3% % ma, A Thru-current (Io) A (r.m.s.) Safety Precautions

14 /-U -U (48 x 48 mm) Adapter Y9F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@ to Fixture (Accessory) Mounted to 7 7 Panel ( to 8 mm) -H (48 x 48 mm) (to back of ) -U Wiring Socket Front-connecting Socket PCF- Eleven, M sems screws max. Two, 4.5-dia. holes Terminal ayout/internal Connections (Top View) Mounting Holes Two, 4.5 dia. mounting holes 4±. Note: Can also be mounted to a DIN track. 4 5 max. 3. max. Note: A model with finger protection (PCF--E) is also available. Safety Precautions Operation Back-connecting Socket P3GA dia Note:. Using any other sockets will adversely affect accuracy. Use only the specified sockets.. A Protective Cover for finger protection (Y9A-48G) is also available Terminal ayout/internal Connections (Bottom View)

E5CN/E5CN-U (48 x 48 mm)

E5CN/E5CN-U (48 x 48 mm) Basic-type Digital Temperature Controller /-U (48 x 48 mm) CSM -U_DS_E_3_ New 48 x 48-mm Basic Temperature Controller with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive

More information

E5CN/E5CN-U (48 x 48 mm)

E5CN/E5CN-U (48 x 48 mm) Basic-type Digital Temperature Controller /-U (48 x 48 mm) CSM -U_DS_E_5_1 New 48 x 48-mm Basic Temperature Controller with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive

More information

E5CN/E5CN-U (48 x 48 mm)

E5CN/E5CN-U (48 x 48 mm) Basic-type Digital Temperature Controller /-U (48 x 48 mm) CSM -U_DS_E_5_7 New 48 x 48-mm Basic Temperature Controller with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive

More information

E5AN/E5EN (96 x 96 mm and 48 x 96 mm)

E5AN/E5EN (96 x 96 mm and 48 x 96 mm) Basic-type Digital Temperature Controller E5AN/E5EN (96 x 96 mm and 48 x 96 mm) CSM_E5AN_E5EN_DS_E_4_1 New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with Enhanced Functions and Performance.

More information

Infrared port USB. Control Output 2. (built-in) SSR outputs

Infrared port USB. Control Output 2. (built-in) SSR outputs Advanced Digital Temperature Controller / (96 x 96 mm and 48 x 96 mm) CSM DS_E A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance

More information

Programmable Temperature Controller (Digital Controller)

Programmable Temperature Controller (Digital Controller) Programmable Temperature Controller (Digital Controller) E5AN-HT/ (96 x 96 mm and 48 x 96 mm) _ E Programmable Controllers Join the Series! Program up to 56 segments and take advantage of the high cost

More information

A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance Function.

A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance Function. Advanced Digital Temperature Controller (48 x 48 mm) H44I-E-1 A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance Function.

More information

Bulletin 900-TC. Bulletin 900 TC Temperature/Process Controllers. Certifications. Bulletin 900-TC8 Controller Models

Bulletin 900-TC. Bulletin 900 TC Temperature/Process Controllers. Certifications. Bulletin 900-TC8 Controller Models Bulletin 900-TC Bulletin 900 TC Temperature/Process Controllers Single-loop, high value, ON/OFF, or analog output controllers 1/8 DIN (Bulletin 900-TC8), 1/16 DIN (Bulletin ), and 1/32 DIN (Bulletin )

More information

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma) TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

E5AN-H/E5EN-H. Advanced Digital Temperature Controller

E5AN-H/E5EN-H. Advanced Digital Temperature Controller Advanced Digital Temperature Controller E5AN-H/E5EN-H (96 x 96 mm and 48 x 96 mm) H45I-E- A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02 Temperature Controller Fuzzy Self-tuning Temperature Controller with Advanced PID (2-PID) Control DIN-size: 6 x 6 mm (E5AJ), 2 x 2 mm (E5BJ), 4 x 4 mm (E5CJ), 4 x 6 mm (E5EJ) Fuzzy self-tuning and Auto-tuning

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

Temperature Controller

Temperature Controller E5AN Temperature Controller Temperature Controller OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku,

More information

INSTRUCTION MANUAL Micro-computer based digital indicating controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

Digital Heater Element Burnout Detector K8AC-H

Digital Heater Element Burnout Detector K8AC-H Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

Instruction manual Micro-computer based digital indicating controller

Instruction manual Micro-computer based digital indicating controller Instruction manual Micro-computer based digital indicating controller JCS-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual.

More information

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller

More information

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Instruction manual for DIN rail mounting type indicating controller DCL-33A Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTI MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E6 28.8 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER MODEL AL3 7 5 - AL3000 series conforming to CE, UL and CSA are 100mm multi-point type hybrid recorders with a simultaneous display of multi-channel

More information

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately) Digital Panel Meter Low-cost, High-quality Digital Thermometer with Built-in Microcomputer Compact DIN-size (96 x 48 x 66 (W x H x D)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100 INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

DIGITAL INDICATOR JIR-301-M

DIGITAL INDICATOR JIR-301-M DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when

More information

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,

More information

Instruction manual Temperature Controller KT7

Instruction manual Temperature Controller KT7 Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

GCS-300 No.GCS31E

GCS-300 No.GCS31E INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller GCS-00 No.GCS1E 200.0 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information

Digital Temperature Controller E5AZ

Digital Temperature Controller E5AZ Digital Temperature Controller E5AZ New Generation of Digital Temperature Controller Depth of only 78mm. Various temperature inputs: thermocouple, platinum resistance thermometer, infrared temperature

More information

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F Temperature Controller 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to ±0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable

More information

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See NEW»»» Changes in the color of the PV show the current status. You can select between different patterns for color combinations. If a certain status occurs, the status will be displayed alternating with

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY600 (96mm X 48mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad. INSTRUCTI MANUAL (EXCERPT) Digital Indicating Controller ACS-13A- /A (For Use with the Infrared Temperature Sensor RD-500) No.ACS11AE1 2011.07 The digital indicating controller ACS-13A /A is an exclusive

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A Preface Thank you for the purchase of our Microcomputer based Temperature Indicating Controllers JCD-13A or

More information

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function

More information

E5CN Temperature Controller User s Manual

E5CN Temperature Controller User s Manual E5CN Temperature Controller User s Manual Revised July 2003 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in

More information

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY900 (96mm X 96mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL Preface Thank you for purchasing our Digital indicating controller FCS-23A. This manual contains instructions for the mounting, functions, operations

More information

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0) Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 PV PV AT AT OUT1 OUT2/HB A1 A2 OUT1 OUT2/HB A1 A2 MODE OUT MODE OUT GCD GCR Preface Thank you for the purchase

More information

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER 1 DCL-A DC No.DCLDCE1 2007.01 Thank you for purchasing our DIN rail mounting type indicating controller DCL-A DC. This manual contains instructions

More information

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White Digital Panel Meters 47 Series CT DIGITA PANE METER (4½ digit, ED display type, true RMS sensing) Functions & Features 4 ½ digit CT input digital panel meter 1/8 DIN size Moving average function to suppress

More information

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER DCL-A No.DCL1E5 200.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY

More information

UDC 700 Universal Digital Controllers and Indicator Specifications

UDC 700 Universal Digital Controllers and Indicator Specifications UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality

More information

UDC100 Universal Digital Controller Specifications

UDC100 Universal Digital Controller Specifications UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit ABB MEASUREMENT & ANALYTICS DATA SHEET C50 1/16 DIN controller / alarm unit 2 C50 1/16 DI N CON TROLL ER / AL ARM U NIT DS/C 50-E N RE V. M Measurement made easy C50 the 1/16 DIN controller to suit your

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for choosing Delta DTE series temperature controller. Please read this instruction sheet carefully before using your DTE to ensure proper

More information

DIGITAL INDICATOR DI25

DIGITAL INDICATOR DI25 DIGITAL INDICATOR DI25 Operating instructions Preface Thank you for purchasing our digital indicator DI25. This manual contains instructions for the mounting, functions, operations and notes when operating

More information

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485 Select Option Device Wise Device/Group HumiLog Y-Axis Text Show/Hide Ledgends MIN MAX Scale Y Max 08-05-2015 15:17:59 PV_C PV_RH Color default default Graph Refresh Interval 2 Set Interval PV Low Alarm

More information

General Specifications

General Specifications General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Functions & Features 6-digit digital panel meter 1/8 DIN size Process integration/totalization with scaling factor adjustment

More information

Temperature Controllers E5CSV

Temperature Controllers E5CSV Temperature Controllers E5CSV Simple to Set and Operate 1/16 DIN Size Controllers Easy setting using internal DIP and rotary switches / or PID control (with on-demand auto-tuning) selectable Clearly visible

More information

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection SA00 SA00 SA00 SA00 Temperature Limit ontroller SA00L FM APPROVED SA00L General Description The SA00L is a FM approved high limit or low limit controllers. The SA00 is a socket mounting type temperature

More information

E5CN-FR Limit Controller USER S MANUAL

E5CN-FR Limit Controller USER S MANUAL Cat. No. H133-E1-01 E5CN-FR Limit Controller USER S MANUAL E5CN-FR Limit Controller User s Manual Produced October 2004 iv Preface OMRON products are manufactured for use according to proper procedures

More information

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...

More information

TEMPERATURE CONTROL MODULE MODEL R3-TC2

TEMPERATURE CONTROL MODULE MODEL R3-TC2 INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...

More information

Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL

Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL Cat. No. H113-E1-03B E5ZN Temperature Controller OPERATION MANUAL E5ZN Temperature Controller Operation Manual Revised November 2005 Notice: OMRON products are manufactured for use according to proper

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC. High Resolution Temperature Controller REX-F9000 Instruction Manual RKC INSTRUMENT INC. IM9000F01-E5 All Rights Reserved, Copyright 1999, RKC INSTRUMENT INC. Thank you for purchasing this RKC product.

More information

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL DIN RAIL MOUNTED INDICATING CONTOLLER DCL-A INSTRUCTION MANUAL Preface Thank you for purchasing our DIN rail mounted indicating controller DCL-A. This manual contains instructions for the mounting, functions,

More information

MICROJET RECORDER (180mm)

MICROJET RECORDER (180mm) MICROJET RECORDER (180mm) DATA SHEET This recorder can record a maximum of 12 channels of DC voltage, ma, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible to record

More information

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER KL4000 Series hybrid recorders realize simple and easy operation as analog recorders. Not only can each measured value be read from the custom

More information

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA TC3YF Freezing/ type DIN W72 H36mm Freezing/ type Features ON/ Control Input specification - Basic specification: NTC(Thermistor), Option: RTD(DPt100Ω) Temperature display range NTC type: -40.0 to 99.9

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

Digital Temperature Controllers

Digital Temperature Controllers 1 Introduction Digital Temperature Controllers User s anual E5@D 2 Preparations 3 Part Names and Basic Procedures 4 Basic Operation 5 Advanced Operations 6 Parameters 7 User Calibration A Appendices I

More information

MICROJET RECORDER (24-CHANNEL 180mm)

MICROJET RECORDER (24-CHANNEL 180mm) MICROJET RECORDER (24-CHANNEL 180mm) DATA SHEET PHB This recorder can record a maximum of 24 channels of DC voltage, ma, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible

More information

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC.

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC. SR Mini HG SYSTEM High-performance Multi-point Control System SR Mini HG SYSTEM Hardware Instruction Manual RKC INSTRUMENT INC. IMSRM15-E6 Modbus is a registered trademark of Schneider Electric. The name

More information

CN4800 Series CONTROLLER

CN4800 Series CONTROLLER CN4800 Series CONTROLLER Operator's Manual PV SV OUT1 OUT2 ALM1 ALM2 SEL M1791/0502 Contents I. PREPARING THE OPERATION... 4 1. THE BASIC INSTALLATION PROCEDURE... 5 2. CHECK OF SPECIFICATIONS... 6 2.1

More information

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 11/98 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 & UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers which

More information

MICRO CONTROLLER S Z SERIES

MICRO CONTROLLER S Z SERIES Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

Table of Contents SECTION PAGE

Table of Contents SECTION PAGE Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................

More information

+ A B V B NO NC V COM PV PV

+ A B V B NO NC V COM PV PV + - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

370, boulevard de Balmont LYON Tel Fax Web:

370, boulevard de Balmont LYON Tel Fax Web: AUTOMATISME Régulateurs de température delta DELTA développe, dessine, fabrique des composants et des équipements électronique pour les plus importants constructeurs internationaux. Fort de ses 30.000

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS... SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................

More information

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN616A Universal 6 Channel ¼ DIN Process Controller omega.com info@omega.com U.S.A. Headquarters:

More information

OPERATOR S MANUAL. TDA-5B Aerosol Generator

OPERATOR S MANUAL. TDA-5B Aerosol Generator OPERATOR S MANUAL for the TDA-5B Aerosol Generator Revision E Air Techniques International Division of Hamilton Associates, Inc 11403 Cronridge Drive Owings Mills, MD 21117 USA TEL 410-363-9696 FA 410-363-9695

More information