Executive Summary. Shell Offshore Inc. BY: Keith M. Gonzales Sr., P.E. Regulatory Requirements for Hazardous Locations

Size: px
Start display at page:

Download "Executive Summary. Shell Offshore Inc. BY: Keith M. Gonzales Sr., P.E. Regulatory Requirements for Hazardous Locations"

Transcription

1 Contents Executive Summary... 1 Regulatory Requirements in the Gulf of Mexico for Hazardous Locations... 2 Referenced Codes and Standards... 2 Memorandum of Agreement... 2 Bureau of Ocean Energy Management Regulation and Enforcement... 2 American Petroleum Institute... 3 NFPA 70 (National Electrical Code)... 3 United States Coast Guard... 5 Executive Summary All electrical equipment installed in the Gulf of Mexico (GOM) where the Bureau of Ocean Energy Management Regulation and Enforcement (BOEMRE; Formerly the MMS) and the United States Coast Guard (USCG) are the Authorities Having Jurisdiction (AHJ), must meet American standards regardless if the facility is designed to American Class and Division or American Class and Zone as defined by the American Petroleum Institute (API). The API Class and Zone option is often confused with the Class & Zone that is defined by International Electrotechnical Commission (IEC) & European Standards, however IT IS NOT THE SAME. Equipment that will be used in the API Class & Zone must be certified & labeled AEx, meaning that it was tested to American (ANSI /UL) standards. The use of IEC/European electrical equipment (ATEX, Ex, EEx, CE, etc.) is not allowed in the API Class & Division/Zone on GOM production facilities. 1. Per 30CFR250 the AHJ on GOM production facilities requires that hazardous area classification be based on API RP 500 (Class & Division) or API RP 505 (Class & Zone) AND electrical equipment being installed in such areas MUST be done so in accordance with API RP 14F or API RP 14FZ. 2. API RP 14F and 14FZ requires that electrical equipment be installed per the National Electrical Code (NEC). 3. The NEC requires all electrical equipment to be marked for the Hazardous Area that it will be installed as certified by a Nationally Recognized Testing Laboratory (NRTL). The NRTL list is owned by the Occupational Safety & Health Administration (OSHA). ATEX is not an NRTL per OSHA. These NRTL s must test to ANSI/UL standards to be acceptable. 4. All Shell facilities currently in the Gulf of Mexico are designed to Class & Division (API RP 500). Therefore all equipment installed on a Shell GOM facility must meet the requirements of API RP 14F and the NEC. 5. This means all electrical equipment installed in a Hazardous Area on Shell GOM facilities must be certified for Class & Division. There is an allowance in the NEC to use zone rated equipment in Division 2 areas that is certified and labeled AEx, which is tested to American Standards. 6. The use of IEC/European electrical equipment (ATEX, Ex, EEx, CE, etc.) in Hazardous Areas on GOM production facilities is not allowed per AHJ regulatory requirements. Regulatory Requirements in the Gulf of Mexico for Hazardous Locations.docx Page 1 of 6

2 Regulatory Requirements in the Gulf of Mexico for Hazardous Locations Below are the regulatory references that show the requirements to which we design and build our facilities. These requirements are either in the Code of Federal Regulations (CFR) or referenced there in. The understanding of these requirements is from the CFR written requirement and the result of working with regulators and established governmental submittal and approval practices. Referenced Codes and Standards 30 CFR Mineral Resources, Bureau of Ocean Energy Management and Enforcement 46 CFR Shipping, United States Coast Guard Requirements API RP 500 Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class 1, Division 1 and Division 2 API RP 14F Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class 1, Division 1 and Division 2 Locations NFPA 70 National Electrical Code, with Governmental references to the 2002 edition. All referenced requirements were verified in the 2011 edition of the same. Memorandum of Agreement The Memorandum of Agreement (MOA) between the USCG and the BOEMREdefines the AHJ for the particular systems of a floater. For the purposes of installing electrical equipment in hazardous areas on a GOM production facility the USCG and the BOEMRE have shared jurisdiction. The following requirements are the same for both fixed leg and floating production facilities. Bureau of Ocean Energy Management Regulation and Enforcement The BOEMRE requirements are found in 30 CFR and are attached below. TITLE 30--MINERAL RESOURCES CHAPTER II--MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR PART 250_OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF--Table of Contents Subpart A_General Sec How must I install and operate electrical equipment? The requirements in this section apply to all electrical equipment on all platforms, artificial islands, fixed structures, and their facilities. (a) You must classify all areas according to API RP 500, Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I, Division 1 and Division 2, Regulatory Requirements in the Gulf of Mexico for Hazardous Locations.docx Page 2 of 6

3 or API RP 505, Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2. (b) Employees who maintain your electrical systems must have Expertise in area classification and the performance, operation and hazards of electrical equipment. (c) You must install all electrical systems according to API RP 14F, Recommended Practice for Design and Installation of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Division 1, and Division 2 Locations (incorporated by reference as specified in Sec ), or API RP 14FZ, Recommended Practice for Design and Installation of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Zone 0, Zone 1, and Zone 2 Locations (incorporated by reference as specified in Sec ). (d) On each engine that has an electric ignition system, you must use an ignition system designed and maintained to reduce the release of electrical energy. American Petroleum Institute The American Petroleum Institute (API) standards API RP 500 give the requirements for defining Hazardous Locations & API RP 14F gives the requirements for installing electrical equipment in those Hazardous Areas. In API RP 14F the following excerpts are pertinent to equipment installation. API RP 14F Section Applicability of National Electrical Code Electrical systems for offshore petroleum facilities shall be designed and installed in accordance with the National Electrical Code, 2008 edition, except where specific departures are noted. NFPA 70 (National Electrical Code) In the National Electrical Code (NEC) (NFPA edition), Zone Equipment is ONLY allowed according to 501.5, inserted below, with the caveat that it be labeled to 505.9(C)(2). The 505.9(C)(2), inserted below, requirement requires the equipment to be AEx certified. This means that it must be tested to American ANSI / UL standards. The small amount of equipment that is AEx certified often bears the Class and Division approval label in lieu of using this rule for applicability. Regulatory Requirements in the Gulf of Mexico for Hazardous Locations.docx Page 3 of 6

4 NFPA 70 (NEC) Zone Equipment Equipment listed and marked in accordance with 505.9(C) (2) for use in Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2 locations for the same gas and with a suitable temperature class. Equipment listed and marked in accordance with 505.9(C)(2) for use in Zone 0 locations shall be permitted in Class I, Division 1 or Division 2 locations for the same gas and with a suitable temperature class. NFPA 70 (NEC) 505.9(C)(2) (2) Zone Equipment. Equipment meeting one or more of the protection techniques described in shall be marked with all of the following in the order shown: (1) Class (2) Zone (3) Symbol AEx (4) Protection technique(s) in accordance with Table 505.9(C)(2)(4) (5) Applicable gas classification group(s) in accordance with Table 505.9(C)(1)(2) (6) Temperature classification in accordance with 505.9(D)(1) Interestingly enough the NFPA 70 (NEC) Handbook 2011 Edition does offer a Fine Print Note, inserted below that gives the clarification that AEx means the equipment is tested to American Standards. It further gives the meaning of EEx and Ex, which are not compatible. Fine Print Note following NFPA 70 (NEC) 505.9(C)(2) The symbol AEx identifies the equipment as meeting American standards. In European Common Market countries, the symbol is EEx. In the IEC standards, on which American and European standards are based, the symbol is Ex. Regulatory Requirements in the Gulf of Mexico for Hazardous Locations.docx Page 4 of 6

5 API RP 14F Section Requires equipment that will be installed to be marked with Class & Division or Class & Zone with AEx certifying that it meets the American ANSI / UL standards. API RP 14F Section marking Equipment for use in hazardous locations shall be marked in accordance with items 1 or 2, below: 1) Division Equipment Equipment required by the National Electrical Code to be approved and labeled for Class I, Division 1 or Class I, Division 2 locations shall be marked to show the class, group and operating temperature or temperature range (see temperature identification number ) referenced to a 40 C ambient as follows: a) Class 1, Division 1 or Class I, Division 2, as applicable; and b) applicable gas classification group(s); and c) temperature classification. NOTE Equipment suitable for ambient temperatures exceeding 40 C shall additionally be marked with the maximum ambient temperature. 2) Zone Equipment Markings for relevant types of zone rated equipment are described in API 14FZ. In further requirement of the Zone markings section 4.6.4, inserted below, explains the same requirement that is found in the National Electrical Code Equipment listed and marked in accordance with NEC 505.9(C)(2) [Class, Zone, Symbol AEx, Protection technique(s) in accordance with Table 505.9(C)(2)(4) in the NEC, applicable gas classification group(s) in accordance with Table 505.9(C) in the NEC, and the temperature classification in accordance with 505.9(D)(1) in the NEC] for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2 locations for the same gas and with a suitable temperature class. United States Coast Guard The United States Coast Guard Code of Federal Regulations also enforces the same requirements as the API and NEC above. Inserted below is 46 CFR through which clearly requires the installation to be according to American OR European standards. Section incorporates the National Electrical Code (NFPA edition). 46 CFR through TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 111_ELECTRIC SYSTEMS_GENERAL REQUIREMENTS--Table of Contents Subpart _Hazardous Locations Sec Applicability; definition. Regulatory Requirements in the Gulf of Mexico for Hazardous Locations.docx Page 5 of 6

6 This subpart applies to installations in hazardous locations as defined in NFPA NEC 2002 and in IEC (both incorporated by reference; see 46 CFR ). As used in this subpart, ``IEC series'' means IEC , IEC , IEC , IEC , IEC 79-6, IEC , IEC , IEC , and IEC (all incorporated by reference; see 46 CFR ). Subpart _Hazardous Locations Sec General requirements. All electrical installations in hazardous locations must comply with the general requirements of section 33 of IEEE (incorporated by reference; see 46 CFR ), and with either Articles 500 through 505 of NFPA NEC 2002 (incorporated by reference; see 46 CFR ) or with the IEC series (as defined in 46 CFR and incorporated by reference; see 46 CFR ). When installations are made in accordance with NFPA NEC 2002 articles, and when installed fittings are approved for the specific hazardous location and the cable type, marine shipboard cable that complies with 46 CFR subpart may be used instead of rigid metal conduit. [USCG , 73 FR 65199, Oct. 31, 2008] Regulatory Requirements in the Gulf of Mexico for Hazardous Locations.docx Page 6 of 6

Overview of Standards for CO Detection Products

Overview of Standards for CO Detection Products Overview of Standards for CO Detection Products Rev 1.1 1 General Overview... 3 2 Application and Installation Codes & Standards... 3 3 Product Standards... 4 4 Certified and Listed Products (Conforms

More information

ORDINANCE NO

ORDINANCE NO ORDINANCE NO. 2017-08-031 AN ORDINANCE OF THE CITY OF LANCASTER, TEXAS, REPEALING THE NATIONAL ELECTRICAL CODE 2014 EDITION IN ITS ENTIRETY AND REPLACING IT WITH THE ADOPTION OF THE NATIONAL ELECTRICAL

More information

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification Electrical Engineering Guide for Determining Electrical Area Classification PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice

More information

Emergency response lock box unit contents and maintenance.

Emergency response lock box unit contents and maintenance. 3750-75-04 Emergency response lock box unit contents and maintenance. [Comment: For dates of non-regulatory government publications, publications of recognized organizations and associations, federal rules,

More information

Setting the Standard in Third-party Certification

Setting the Standard in Third-party Certification Setting the Standard in Third-party Certification 1 Benefits enjoyed by FM Approvals customers FM Approvals can help you: Meet client demands Fulfill jurisdictional requirements Differentiate your product

More information

Guide to Intrinsically Safe Portable Radios

Guide to Intrinsically Safe Portable Radios Guide to Intrinsically Safe Portable Radios An overview of common IS standards www.taitradio.com GUIDE TO INTRINSICALLY SAFE PORTABLE RADIOS SUMMARY The development of equipment for explosive atmospheres

More information

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED October 3rd, 2017 Vincent W. Wedelich, PE, MBA Project Manager Associate Electrical Engineer 10 Years

More information

Meeting NFPA standards for

Meeting NFPA standards for 24 Fire safety Meeting NFPA standards for flame, smoke and gas detection Fire is one of the most critical hazards in any built environment, and industrial processes and facilities that involve volatile

More information

Addendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017

Addendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017 Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD 21801 Ph. 410-548-4805 Fax 410-334-3130 Email: purchasing@wicomicocounty.org Addendum # 2 Wicomico County Circuit Court Second Floor

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 44 16 (May 2015) ------------------------ Preparing Activity: NASA Superseding UFGS-10 44 16 (May 2012) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement

More information

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc. Chapter 1 GROUNDING AND BONDING 1 Proper grounding practices protect people from the hazards of electric shock and ensure the correct operation of overcurrent protection devices. Grounding is the intentional

More information

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents SECTION 01410 PART I - GENERAL 1.01 SECTION INCLUDES A. Relationship between Code, Ordinances, Standards and Contract Documents B. Applicable Codes, Laws and Ordinances C. Project Inspections D. Office

More information

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES Copyright Material PCIC Europe Paper No. PCIC Europe LO-70 Allan Bozek EngWorks, Inc. 1620 49 th Avenue, SW Calgary, AB T2T

More information

UFGS (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-10 44 16 (May 2009) ------------------------- Preparing Activity: NASA Superseding UFGS-10 44 16 (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in

More information

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input Public Input No. 4-NFPA 111-2016 [ Section No. 1.1.4.1 ] 1.1.4.1 * This standard shall not cover the following: (1) Application of the SEPSS (2) Distribution wiring (3) Systems having total outputs less

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

RAGAGEP: Codes, Standards, and Good Engineering Practice PETER THOMAS, P.E. PRESIDENT AND ENGINEER RESOURCE COMPLIANCE

RAGAGEP: Codes, Standards, and Good Engineering Practice PETER THOMAS, P.E. PRESIDENT AND ENGINEER RESOURCE COMPLIANCE RAGAGEP: Codes, Standards, and Good Engineering Practice PETER THOMAS, P.E. PRESIDENT AND ENGINEER RESOURCE COMPLIANCE PTHOMAS@RESOURCECOMPLIANCE.COM Introduction PSM RAGAGEP References Title 29 1910.119(d)(3)(ii)

More information

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within

More information

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove Jim Dungar, P.E. Principal Engineer Schneider Electric Engineering Services Jim.dungar@schneider-electric.com (920-766-8012)

More information

Emery County Senior Center Green River 06/07

Emery County Senior Center Green River 06/07 SECTION 260923 - LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

CURTIS-STRAUS LLC A BUREAU VERITAS COMPANY NRTL/SCC SOLUTION

CURTIS-STRAUS LLC A BUREAU VERITAS COMPANY NRTL/SCC SOLUTION CURTIS-STRAUS LLC A BUREAU VERITAS COMPANY NRTL/SCC SOLUTION WHAT IS NRTL/SCC SOLUTION? Nationally Recognized Test Laboratories (NRTLs) in the United States and Testing Organizations/Certification Bodies

More information

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014 Policy Title: Electrical Safety Work Practice Program Policy Number: UNIV-EHS 430 Policy Approved: January 2014 Policies Superseded: FINA-730 Policy Management Area: Environmental Health and Safety Created/Revision(s):

More information

Not For General Distribution. For Committee Ballot 4053 Use Only. Draft 6: 10/07/2016

Not For General Distribution. For Committee Ballot 4053 Use Only. Draft 6: 10/07/2016 This document is not an API Standard; it is under consideration within an API technical committee but has not Draft 6: 10/07/2016 Recommended Practice for Design, Installation, and Maintenance of Electrical

More information

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES Limassol 20 th August, 2015 RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES This document is intended to provide clarification on the use of FirePro Condensed Aerosol Generators in Potential Explosive

More information

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency TABLE OF CONTENTS Introduction Why are dust threats so serious? Key Points: NFPA 652 Key Points: ATEX What do you

More information

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems Products Solutions Services CT287 Hazardous Area Classifications and Protection Systems Slide 1 Topics covered Types of Hazardous Area classifications with focus on North America Types of hazardous protection

More information

Pilz Safety Lockout System (PSLS)

Pilz Safety Lockout System (PSLS) Pilz Safety Lockout System (PSLS) An alternative isolation method for LOTO By Doug Sten, Safety Consultant, Pilz Automation Safety Objectives Challenges with manual, mechanical isolation disconnects Challenges

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below

More information

Certificate of Compliance

Certificate of Compliance FF02 Certificate of Compliance Certificate: 70068210 Issued to: Cascade Technologies Ltd Glendevon House, Castle Business Park, Stirling, Scotland. UNITED KINGDOM FK9 4TZ Attention: Mr M Douglas. The products

More information

Article by: Ark Tsisserev, Principal, Stantec Consulting Ltd.

Article by: Ark Tsisserev, Principal, Stantec Consulting Ltd. Re: CEC 2012 Article by: Ark Tsisserev, Principal, Stantec Consulting Ltd. Conductors Do we have a problem with this? Apparently, we do. However, there is no reason to generalize this problem. Although

More information

Page 1 of 13 Second Revision No. 1-NFPA 326-2014 [ Section No. 2.3.1 ] 2.3.1 ACGIH Publications. American Conference of Governmental Industrial Hygienists, 1330 Kemper Meadow Drive, Cincinnati, OH 45240-1634.

More information

Legislation, Standards and Technology. Figure 1: 1897 Approved Electrical Fittings

Legislation, Standards and Technology. Figure 1: 1897 Approved Electrical Fittings Legislation, Standards and Technology FM Approvals Roots in the industrial revolution 1835 and the development to present by John Rennie and Bill Lawrence Figure 1: 1897 Approved Electrical Fittings In

More information

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item Public Comment No. 23-NFPA 96-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM E84, Standard Test Method

More information

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING SEMINAR 301 Part 1: Changes in the 2005 NEC SEMINAR RULES: There are no Rules All Questions need to be asked Stop at any time for an explanation SEMINAR PARTS: ELECTRIC and NEON SIGN STANDARDS By Randy

More information

MSC Guidelines for Automatic Sprinkler Systems

MSC Guidelines for Automatic Sprinkler Systems S. J. Kelly, CDR, Chief of Engineering Division References a. Title 46 CFR 56.20, 56.50 & 56.60 (Subchapter F) b. National Fire Protection Association (NFPA) 13, 1996 Edition, Installation of Sprinkler

More information

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ] 8 of 93 11/6/2015 7:41 AM Public Input No. 52-NFPA 30-2015 [ Section No. 21.2 [Excluding any Sub-Sections] ] For the purpose of this chapter, the term in this section shall have the definitions given.

More information

Osha Technical Manual Section Iii Chapter 5 Noise Measurement

Osha Technical Manual Section Iii Chapter 5 Noise Measurement Osha Technical Manual Section Iii Chapter 5 Noise Measurement Portable heat stress meters or monitors are used to measure heat conditions. FR 35265), "..basic chemical manufacturing processes and abnormal

More information

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS PART 1 GENERAL 1.01 SUMMARY SECTION 26 22 00 (16460) - LOW-VOLTAGE TRANSFORMERS A. Section Includes: 1. Dry-Type Distribution And Specialty Transformers Rated 1000 V And Less. a. General-Purpose Distribution

More information

PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification September 2016 Electrical PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

NFPA 70E Electrical Safety & Arc Flash Training

NFPA 70E Electrical Safety & Arc Flash Training NFPA 70E Electrical Safety & Arc Flash Training OSHA 1910.332(a) Training, 1910.332(a) Scope. The training requirements contained in this section apply to employees who face a risk of electric shock that

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards v2-5058-co900h Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 1 Agenda 1. Background 2. Related Electrical

More information

NFPA Marine Fire Protection Codes and Standards An Overview. Guy R. Colonna, P.E. National Fire Protection Association. Quincy, MA USA

NFPA Marine Fire Protection Codes and Standards An Overview. Guy R. Colonna, P.E. National Fire Protection Association. Quincy, MA USA Proceedings of the ASME/USCG 2013 3rd Workshop on Marine Technology and Standards MTS2013 July 24-25, 2013, Arlington, VA, USA MTS2013-0321 NFPA Marine Fire Protection Codes and Standards An Overview Guy

More information

Are You Prepared? The impending impact of Code on Servicing Security Systems

Are You Prepared? The impending impact of Code on Servicing Security Systems Sam Docknevich, PSP, Security Service Portfolio Manager Are You Prepared? The impending impact of Code on Servicing Security Systems Siemens AG 2015 All rights reserved. usa.siemens.com/infrastructure-cities

More information

Industrial Machinery Standards:

Industrial Machinery Standards: NFPA 79 for the US in comparison to IEC / EN 60204-1 (2016 Edition) Intertek 70 Codman Hill Road Boxborough, MA 01719 www.intertek.com/hazloc 1-800-WORLDLAB icenter@intertek.com Introduction Every year,

More information

Navigating The Product Certification Maze: Building Codes and Product Standards. AGENDA be Covered

Navigating The Product Certification Maze: Building Codes and Product Standards. AGENDA be Covered AGENDA be Covered Navigating The Product Certification Maze: Understanding the Product Testing & Certification Process and Certification Marks BSC Course No. 49-6664 Presenter: Lisa Reiheld, CSA Group

More information

Desiccant. Breather Range

Desiccant. Breather Range Desiccant 127 Breather Range 128 HBP & HB Types Transformer Breather Units & Accessories Desiccant Breather Range Why Choose Hawke? When specifying products used in critical electrical supply applications

More information

Brian Knapp & Johnny Wheat

Brian Knapp & Johnny Wheat PRESENTED BY: 4B Components Limited Brian Knapp & Johnny Wheat YOUR PROBLEM: Grain dust is explosive YOUR SOLUTION: Remove one of the elements from the dust explosion pentagon Ignition Source (Heat) Dispersion

More information

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input Public Input No. 16-NFPA 211-2014 [ Section No. 2.3.1 ] 2.3.1 ASHRAE Publications. ASHRAE, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. ASHRAE Handbook: HVAC Systems and Equipment, 2008 2012.

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2792948 Issued to: Siemens Canada Limited 1954 Technology Drive Peterborough, ON K9J 7B1 Canada Attention: Mr. Lee Rogers The products listed below are eligible

More information

[Project Location] SECTION FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES

[Project Location] SECTION FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES SECTION 28 23 29 FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES DIVISION 28- ELECTRONIC SAFETY AND SECURITY 28 20 00 ELECTRONIC SURVEILLANCE 28 23 00 VIDEO SURVEILLANCE

More information

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017 Procedure Number: E1-03 Revision Date: 02/16/2017 References: S. T. Brady, CDR, Chief, Engineering Division a. National Fire Protection Association (NFPA) 750, 1996 Edition, Standard on Water Mist Fire

More information

MSC Guidelines for Foam Fire Suppression Systems

MSC Guidelines for Foam Fire Suppression Systems References: S. T. Brady, CDR, Chief, Engineering Division a. 46 CFR 34.17, Tank Vessel Fixed Foam b. 46 CFR 34.20, Tank Vessel Deck Foam c. 46 CFR 76.17 Passenger Vessel Foam d. 46 CFR 95.17, Cargo Vessel

More information

NFPA 37 Public Comment Responses Page 1 of 32

NFPA 37 Public Comment Responses Page 1 of 32 of 30 11/4/2016 3:05 PM Public Comment No. 6-NFPA 37-2016 [ New Section after 1.6 ] TITLE OF NEW CONTENT Type your content here... 1.7 Pressure Measurement. All pressures expressed in this document are

More information

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services www.intertek.com/lighting 1 Identifying Product Safety Requirements for Your Target Markets

More information

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM 1. GENERAL SPECIFICATION 1.1. A total flooding, FM-200 fire suppression system, super-pressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by volume in all designated

More information

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018 Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018 Automatic FireAlarm Association SURVIVING SURVIVABILITY - A USER S GUIDE TO Larry D. Rietz, SET

More information

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool Hazardous Area Classification in Oil & Gas Industry A Fire Prevention Tool SFPE ENGINEERING TECHNOLOGY CONFERENCE Oct 4, 2010 New Orleans, LA 1 Overview Oil and gas plants handle flammable materials 2

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin June 2018 CEC-18 [rev-13] Page 1 of 6 CANADIAN ELECTRICAL CODE SUBJECT: Section 18 Hazardous locations Rule 18-006 Locations containing an explosive gas atmosphere

More information

SPECIFICATION: ARGONITE Engineered Fire Suppression System

SPECIFICATION: ARGONITE Engineered Fire Suppression System 1. GENERAL SPECIFICATION 1.1 A total flooding, clean agent, fire suppression system, filled with Argonite agent shall be installed to meet a minimum design concentration of %, by volume in all designated

More information

ABB s ATEX jargon buster explains the terminology users are likely to encounter when purchasing motors for hazardous areas.

ABB s ATEX jargon buster explains the terminology users are likely to encounter when purchasing motors for hazardous areas. ATEX Jargon Buster ATEX Jargon Buster ABB s ATEX jargon buster explains the terminology users are likely to encounter when purchasing motors for hazardous areas. ABB s ATEX Jargon Buster uses hyperlinks

More information

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement 1 of 7 3/4/2016 12:02 PM Second Revision No. 5-NFPA 56-2016 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by

More information

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION EXIT ROUTES, EMERGENCY ACTION PLANS, AND FIRE PREVENTION PLANS PART 1: INTRODUCTION Applicability of This Module Use the following General Applicability Checklist to determine whether a rulebook and its

More information

Brighton Area Fire Authority

Brighton Area Fire Authority 615 W. Grand River Ave. Brighton, MI 48116 o: 810-229-6640 f: 810-229-1619 January 14, 2019 Fire Alarm Contractors RE: Fire Alarm Credential & Submittal Requirements To Whom It May Concern: The following

More information

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection 1. GENERAL SPECIFICATION 1.1 A total flooding, Novec 1230 fluid, fire suppression system, super-pressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by volume in

More information

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition. 1. GENERAL SPECIFICATION 1.1 A total flooding, FM-200 fire suppression system, super-pressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by volume in all designated

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

NEC 2017 Changes and Their Effect Upon the ICT Industry

NEC 2017 Changes and Their Effect Upon the ICT Industry NEC 2017 Changes and Their Effect Upon the ICT Industry Today s Presenters John Kacperski, RCDD, OSP, CDT Chair of BICSI Standards BICSI Representative on NFPA 70-CMP 16 Richard S. Anderson, RCDD, CDT,

More information

Understanding the Regulatory and Standards Process for Products Exported to the U.S. Eric F. Shaver, Ph.D. & Curt C. Braun, Ph.D.

Understanding the Regulatory and Standards Process for Products Exported to the U.S. Eric F. Shaver, Ph.D. & Curt C. Braun, Ph.D. Understanding the Regulatory and Standards Process for Products Exported to the U.S. Eric F. Shaver, Ph.D. & Curt C. Braun, Ph.D. 1150 Alturus Drive #108 Moscow, ID 83703 Tel: 208.892.0620 Fax: 877.641.4468

More information

SECTION ELECTRICAL SYSTEMS COMMISSIONING

SECTION ELECTRICAL SYSTEMS COMMISSIONING SECTION 16990 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Section Includes: 1. General requirements for Commissioning (Cx) of lighting systems components, lighting controls and HVAC systems line voltage

More information

CFSAC REGULATORY REFORM SUBCOMMITTEE RECOMMENDATION REPORT

CFSAC REGULATORY REFORM SUBCOMMITTEE RECOMMENDATION REPORT March 1, 2018 CFSAC REGULATORY REFORM SUBCOMMITTEE RECOMMENDATION REPORT SUBJECT: EVALUATION OF EXISTING COAST GUARD REGULATIONS, GUIDANCE DOCUMENTS, INTERPRETATIVE DOCUMENTS, AND COLLECTIONS OF INFORMATION

More information

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009 Compilation of regulatory approaches used in various countries Information received by the Secretariat through a survey in 2009 At its seventeenth session, the Working Party mandated the Sectoral Initiative

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 82 46.00 40 (May 2017) --------------------------------- Preparing Activity: NASA Superseding UFGS-23 82 46.00 40 (August 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS

APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS All improvements of the facilities within the jurisdiction of the PCJPB shall be in strict conformance with government

More information

Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co.

Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co. Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co. Product Safety Standards Nationally Recognized Testing Laboratory

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

Electrical Safety for Facility Managers and Building Owners

Electrical Safety for Facility Managers and Building Owners CEU s Copy of Slides Evaluation Form Follow up information Disclaimer. This seminar was produced to help explain the importance and need for electrical safety specifically for Facility Managers. It does

More information

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement of 35 1/21/2016 7:56 AM First Revision No. 1-NFPA 30A-2015 [ Section No. 1.1.3 ] 1.1.3* This code shall not apply to those motor fuel dispensing facilities where only liquefied petroleum gas (LP-Gas),

More information

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers BULLETIN 92046 APPLICATION INFORMATION NOVEMBER 2002 SUPERSEDES August 2002 CONTENTS

More information

HAZARDOUS LOCATIONS EXPLOSION PROTECTION SERVICES

HAZARDOUS LOCATIONS EXPLOSION PROTECTION SERVICES UALITÄT IN DER PRODUKTION FEUERBESTÄNDIG CONTROL DE PROCESOS SEGURIDAD INTRÍNSECA ACEITAÇÃO NO MERCADO GLOBAL ITÄT IN DER PRODUKTION EFICIÊNCIA ENERGÉTICA SCHUTZ TURBINEN FEUERBESTÄNDIG EXPLOSÃO LUMINÁRIAS

More information

ONYX FirstVision Specification Interactive Firefighters Display

ONYX FirstVision Specification Interactive Firefighters Display ONYX FirstVision Specification Interactive Firefighters Display NOTIFIER is a registered trademark, and ONYX FirstVision, NOTI FIRE NET, and VeriFire are trademarks of Honeywell International Inc. Microsoft

More information

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour. Everything a firefighter wants to tell a design professional or building code official, in one hour. 1 2 3 1 4 The job of the fire department is to put the wet stuff on the red stuff. 5 Job #1. of the

More information

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM 1 of 213 10/20/2016 11:02 AM Committee Input No. 2505-NFPA 72-2016 [ Global Input ] Change the term visible to visual where appropriate Submitter Information Verification Submitter Full Name: SIG-NAS Organization:

More information

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007 CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications 3 rd Edition www.emersonprocess.com CAT 100 & CAT 200 Addendum for Hazardous Area Applications ESSENTIAL INSTRUCTIONS

More information

ARTICLE 25. FUEL GAS CODE

ARTICLE 25. FUEL GAS CODE ARTICLE 25. Rule 1. Indiana Fuel Gas Code, 2003 Edition (Repealed) (Repealed by Fire Prevention and Building Safety Commission; filed Mar 18, 2008, 2:32 p.m.: 20080423-IR-675070479FRA, eff 90 days after

More information

Title: BFST1505 Syllabus

Title: BFST1505 Syllabus DEPARTMENT OF FINANCIAL SERVICES Division of State Fire Marshal Bureau of Fire Standards and Training Title: BFST1505 Syllabus Revision: April 5, 2018 Section I - Course Information Course Title: Fire

More information

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

Change all instances of flame resistant (hypobaric) to Limited-Combustible (material) in all instances in the document. 1 of 9 10/21/2015 1:22 PM First Revision No. 3-NFPA 99B-2015 [ Global Input ] Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

More information

Report on Proposals June 2013 NFPA 70

Report on Proposals June 2013 NFPA 70 14-1 Log #1170m NEC-P14 Russell LeBlanc, The Peterson School In articles 90 through 830, if the wording is not already there, then add the words (or other structure(s)) after the word BUILDING(S) wherever

More information

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT The interaction of fire protection systems can be extremely complex. The detection of a fire in a building by an automatic device

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes ac,

More information

OPERATIONAL PERMIT STORAGE MAGAZINE PERMIT APPLICATION

OPERATIONAL PERMIT STORAGE MAGAZINE PERMIT APPLICATION PRINCE WILLIAM COUNTY DEPARTMENT OF FIRE AND RESCUE FIRE MARSHAL S OFFICE 5 COUNTY COMPLEX CT. SUITE 160 PRINCE WILLIAM, VA 22192 (703) 792-6360 office (703) 792-6492 fax WWW.PWCGOV.ORG/FIRE For Office

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1469131 (LR 103134) Master Contract: 184981 Issued to: Industrial Monitoring Instr. (IMI) A Div. of PCB Piezotronics, Inc. 3425 Walden Ave Depew, NY 14043 USA Attention:

More information

Narrative Reports As Regulated by 780 CMR, Section 903.0

Narrative Reports As Regulated by 780 CMR, Section 903.0 EXHIBIT 20 Narrative Reports As Regulated by 780 CMR, Section 903.0 903.1.1 - FIRE PROTECTION CONSTRUCTION DOCUMENTS a. Basis (methodology) of design for the protection of the occupancy and hazard for

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Merchant Vessels

More information