Expansion Modules & Accessories

Size: px
Start display at page:

Download "Expansion Modules & Accessories"

Transcription

1 HONEYWELL SECURITY & COMMUNICATIONS Expansion Modules & Accessories Honeywell s wide range of expansion modules and accessories enable you to configure a system to meet any installation challenge and help end-users take full advantage of their security system features. Products include power supplies, switchers, sensors and a full line of devices featuring Honeywell s patented V-Plex polling loop technology, which literally redefines price and performance on a simple pair of wires. THIS SECTION INCLUDES: ADEMCO V-Plex Power Supplies Omni Expansion Modules & Accessories 129

2 Expansion Modules & Accessories ADEMCO EXPANSION ECP-ISO ECP Isolator Helps to maintain the operation of near-side isolated equipment such as fire keypads and communicators in the event of shorts or grounds on the extended ECP bus. Compatibility: - VISTA-128FBP - VISTA-250FBP - FA1670C - FA1700C 4101SN V-Plex Addressable Relay Module One Form C SPDT relay One class B/style B EOLRsupervised aux. input zone Operating power and communication with control panels via the addressable V-Plex polling loop Electronics mounted in a small plastic case with tamper-protected cover Suitable for residential and commercial burglary and fire installations 2.13" W x 3.25" H x 1" D 4190SN V-Plex Two-Zone Expander Closed-circuit devices with or without EOLR supervision Open-circuit devices with EOLR supervision Fast-response (10 millisecond) devices 2.13" W x 3.25" H x 1" D 4193SN V-Plex Two-Zone Expander Makes any hardwired contact device V-Plex ready Built-in serial number for addressing One supervised zone and one unsupervised zone UL listed fire (when mounted inside a UL listed cabinet) and burglary applications Please see page 119 for more information on V-Plex. Please see page 119 for more information on V-Plex. Please see page 119 for more information on V-Plex Relay Module Four on-board programmable relays Applications include sounder, strobe lights or interface to other equipment to provide added convenience Easily wires to the control and fits comfortably inside the cabinet 4204CF Supervised Notification Appliance Module Adds up to two Class B (style Y) supervised notification outputs to compatible ADEMCO panels Applications such as sounders and strobe lights to provide added convenience Easily wires to the control and fits comfortably inside the cabinet Has a built-in cover tamper switch to detect and report the removal of its cover to the panel 4208SN Remote Eight-Zone Interface Module Remote V-Plex zone interface module Supports serial number application 4208SNF Universal Class A and Class B Expander Module Provides up to six Class B supervised zones using external 10k EOL resistors and two Class A supervised loops using built-in 10k EOL resistors Powered from addressable loop or DC power supply Serial number addressing via DIP switch 130

3 Expansion Modules & Accessories ADEMCO EXPANSION 4208U V-Plex Universal Eight-Zone Expander Remote eight-point module (for fire or burglary) Supports both DIP switch and serial number applications Please see page 119 for more information on V-Plex. 4209U Four-Zone V-Plex Group Zoning Module Combines two-wire smoke detectors from an area of protected premises into group zones Supports both DIP switch and serial number applications Can be attached remotely or at the panel All loops are EOLR supervised (2K, supplied) Provides power and super-vision for twowire industry standard smoke detectors 4219 Wired Zone Expander Adds up to eight end-of-line supervised zones Connection made to the control s console wires Comfortably fits inside the controls cabinet Supported on VISTA-15/20 series control panels 4229 Wired Zone Expander/Relay Board Provides eight end-of-line supervised zones Two on-board programmable relays Connection made to the control s console wires Supported on VISTA-15/20 series control panels 4293SN V-Plex Serial Number Interface Module Single-zone expander (unsupervised) Makes any hardwired contact device V-Plex ready Built-in serial number for addressing UL Listed commercial and household burglary applications 4297 V-Plex Polling Loop Extender Module Isolates and protects different areas of protection Extends loop distance Separate DC input, no loop current drain -VSI V-Plex Short Isolator Detects and isolates polling loop branches with complete or resistive shorts Can be used to isolate burglary devices from fire devices LED indicator reduces troubleshooting time and maintenance costs 4.14" L x 2.56" W x 0.87" D Please see page 119 for more information on V-Plex. Please see page 119 for more information on V-Plex. Please see page 119 for more information on V-Plex. 131

4 Expansion Modules & Accessories ADEMCO ACCESSORIES VA8200 Panel Linking Module The VA8200 Panel Linking Module allows multiple control panels to be networked together and controlled from any keypad in the system, letting you control multiple zones, partitions or buildings from one location. Links panels to control multiple systems, and buildings from one central location Up to eight systems can be linked together 6.44" W x 4.5" H x 1.25" D Compatible with VISTA-128BP, VISTA-128FBP, VISTA-250BP,VISTA-250FBP 4286 VISTA Interactive Phone Module This module for any VISTA security system provides remote control access from any touch-tone phone. Customers can conveniently arm, disarm and check their security system status or conduct home automation functions from any location. Performs most keypad functions from a touch-tone phone locally or remotely System can be called to check the system status and arm/disarm security system remotely Operates relays or X-10 receivers on select VISTA panels to control lights and appliances Large vocabulary of words for voice descriptors 6.44" W x 1.25" H x 4.25" D Compatible with all VISTA panels 4500 Thermostat Module Works with the 4286 to expand the home control feature of the VISTA Security System to include temperature control (ESAVR-KT) 6.12" W x 2.88" H x 1.25" D 659EN Line Fault Monitor Monitors phone-line voltage Operates on 6 or 12VDC Form C relay Momentary or maintain relay closure 2.5" W x 6" H x 1.5" D 4100SM Serial Interface Module Interface for printer for VISTA-50P, VISTA-128BP, VISTA-128FBP, VISTA-250BP and VISTA-250FBP Direct wire download interface for VISTA-40, VISTA-50P, VISTA-128BP, VISTA-128FBP, VISTA-250BP and VISTA-250FBP 4" W x 2.75" H x 0.75" D 5140DLM Backup Dialer Provides a secondary supervised dialer output to commercial fire panels: VISTA-128FBP, VISTA-250FBP and VISTA-32FB Voltage is 12VDC 5mA inactive current 15mA active current NFPA-72 compliant Listings: UL/ULC Listed to UL365, UL464, UL609, UL864,UL1610, UL1635, CAN/ULC-S303, CAN/ULC-S304, CAN/ULC-S525, CAN/ULC-S

5 Expansion Modules & Accessories ADEMCO ACCESSORIES 1361X10 X10 Plug-In Transformer Provides 16.5VAC Provides the most powerful yet simple solution for controlling lights and appliances through X10 compatible AC line carrier Provides both power to the panel and direct signaling capability to the existing AC wires Simple to wire Only requires one AC outlet AD12612 Power Supply Provides six or 12VDC 1.2 Amps continuous output to power devices Transformer purchased separately Factory preset at 13.6VDC, with jumper set to 12VDC Battery: Supports a standard 4 AH gel cell battery Transformer required: 6V operation 12VAC, 20VA (Model 1322/TF3) 12V operation 16.5VAC, 40VA (Model 1361) Fuse: 3 Amp fast blow fuse (Model FP1166) Board dimensions: 4" W x 2" H x 1.75" D AD25624 Power Supply Provides 12 or 24VDC 2.5 Amps continuous output to power devices Transformer purchased separately Battery: Supports a standard 4 AH gel cell battery Transformer required: XF30 is recommended and can be used for either 12 or 24VDC operation ( , in red cabinet) Fuse: 6 Amp (Part #N9544) 5 Amp (Part #90-9) Board dimensions: 6.5" W x 2" H x 1.562" D AVS Audio Verification System Two-way voice communication during the event of an alarm allows central station operators to talk directly to end-users and vice-versa ECP four-wire support on AVS control and AVST voice station Enhanced sound quality on AVST (87 db) AVS control mounts directly inside VISTA cabinet Compatible with GSMV for two-way voice use over GSM Compatible with VISTA-15P, VISTA-20P and VISTA-21iP for ECP connections 133

6 Expansion Modules & Accessories OMNI OMNI EXPANSION OMNIEXP8 Hardwired Expansion Module Eight zone wired expander (16 zones with unique zone doubling options) Snaps directly to control board for easy installation Cost effective system expansion 3.5" W x 1.9" H XL4705 Relay Expansion Module Relay expansion module allows five dry form C (SPDT) relay outputs to be added to the OMNI408, OMNI624EU and OMNI848EU Up to four of these modules can be used with the OMNI624EU and OMNI848EU 6" W x 2.75" H 134

7 In business, like everything else, sometimes we take things for granted. But the problem with taking things for granted is that if you re not careful, those things can quickly disappear. To ensure a profitable future, you need to support the Security Industry Alarm Coalition (SIAC). From Washington to Massachusetts, this non-profit organization works with law enforcement and alarm associations, fighting against onerous alarm ordinances. Ordinances that if passed, could seriously jeopardize the profitability of your business. You might say, It doesn t matter if SIAC is helping dealers miles and miles from my business. But if you neglect the problem until it reaches your door, it might be too late. Support SIAC today at 135

8 Notes 136

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing Control Panels Control Panels for Commercial Applications Control panels provide the central processing and logic for an integrated system. In a typical system, there are four major functions: inputs,

More information

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel Designed to integrate seamlessly with, access control, and ADEMCO s full range of fire and burglary components, the

More information

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access Designed to integrate seamlessly with, access control and ADEMCO s full range of fire and burglary components, the VISTA-32FB provides the ultimate protection of life and property. The UL listed Fire and

More information

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS Feature Charts Control Panels FEATURE CHART LYNX Plus (L3000) (Supported Feature) (Not Supported) N/A (Not Applicable) LYNX Touch (L5210)

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE The Door Switch 11772 Westline Industrial Drive St. Louis, Mo 63146 (877) 998-5625 www.thedoorswitch.com Patent No. RE42,991 and RE44,039 CONTROL PANEL TRANSFORMER (SUPPLIED WITH CONTROL PANEL) NOTIFICATION

More information

Honeywell Combination Fire & Burglary Control Panel

Honeywell Combination Fire & Burglary Control Panel Honeywell Combination Fire & Burglary Control Panel Agenda VISTA 128FBPT Fire & Burglary Design & Scalability of VISTA Fire TURBO (FBPT) Honeywell Fire & Intrusion panel USP 5800 Series Wireless Sensor

More information

Security & Communications INTRUSION AND ALARM COMMUNICATIONS

Security & Communications INTRUSION AND ALARM COMMUNICATIONS Security & Communications INTRUSION AND ALARM COMMUNICATIONS Commercial Solutions Guide 2010-2011 1COMMCLCT_Ad_InsideFrontCvr:1ComCat_IFC 3/4/10 4:35 PM Page 1 locked out? Tired of being locked out of

More information

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE K3179V2 2/11 Rev. A ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE FEATURES The ADEMCO 4208SNF Universal Class A Module can be used in either of two different applications.

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216 16-128 Zone Control Panel PC4020 16 zones on main control panel supports up to 16 hardwired keypads Expandable up to 128 zones using hardwire, wireless modules and addressable zones COMBUS hardwired expansion

More information

P Zone Expandable Hybrid Security System

P Zone Expandable Hybrid Security System Page 1 of 11 up to 8 hardwired keypads and 4 wireless keypads 4 hardwired keypads available with zone input PWLS910 wireless handheld keypad added wireless control is provided by - PWLS908 wireless panic

More information

Commercial Burglary Partitioned Security System With Scheduling. Installation and Setup Guide. N5944-6V2 5/04 Rev B

Commercial Burglary Partitioned Security System With Scheduling. Installation and Setup Guide. N5944-6V2 5/04 Rev B VISTA SERIES VISTA-50P/VISTA-50PUL Commercial Burglary Partitioned Security System With Scheduling Installation and Setup Guide N5944-6V2 5/04 Rev B ii Table of Contents List of Figures... v Conventions

More information

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED... ALARM... CONTROL..... PANELS... AND... KEYPADS....- WIRED........ Securi-Prod 4 Zone Perimeter Alarm 4 x EOL zone alarm panel 2K2 Zone EOL resistance value Multiple Arm/Disarm functions Built in receiver

More information

First page of this international document resides under separate cover: 20SEaCOV.ps

First page of this international document resides under separate cover: 20SEaCOV.ps First page of this international document resides under separate cover: 20SEaCOV.ps TABLE OF CONTENTS Section 1. GENERAL DESCRIPTION... 6 Section 2. INSTALLING THE CONTROL... 9 Mounting the Cabinet...

More information

Commercial Fire and Burglary Partitioned Security System with Scheduling

Commercial Fire and Burglary Partitioned Security System with Scheduling ARMED A D S SPACE READY B E T R C F X ENTER MAX INSTANT READY R BYPASS FA1670C/FA1700C Commercial Fire and Burglary Partitioned Security System with Scheduling BS/ESC N/Y SHIFT 1 4 5 6 7 8 9 0 FA560 2

More information

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems Installation and Setup Guide K14488V3 10/12 Rev. C RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of

More information

Integrated Solutions. Integrated Solutions HONEYWELL SECURITY & COMMUNICATIONS. More and more, customer requirements cannot

Integrated Solutions. Integrated Solutions HONEYWELL SECURITY & COMMUNICATIONS. More and more, customer requirements cannot HONEYWELL SECURITY & COMMUNICATIONS Integrated Solutions More and more, customer requirements cannot be met with one solution rather, they need a seamless approach that integrates different elements to

More information

VISTA-100 Commercial Fire & Burglary Partitioned System

VISTA-100 Commercial Fire & Burglary Partitioned System VISTA-100 Commercial Fire & Burglary Partitioned System 4XLFN6WDUW Step-by Step Programming Procedure Single and Multiple Programming Forms System Worksheets FIRE FIRE * PULL VISTA-100PR Rev B 4/99 TABLE

More information

9,67$36HULHV 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH. The formatting of this version has been significantly revised. K5305-1V3 10/03 Rev.

9,67$36HULHV 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH. The formatting of this version has been significantly revised. K5305-1V3 10/03 Rev. ARMED 7 INSTANT 8 CODE 9,67$36HULHV 9,67$36HULHV 6HFXULW\6\VWHPV,QVWDOODWLRQDQG6HW8S*XLGH ARMED READY 1 OFF 4 MAX 7 INSTANT READY 0 2 AWAY 5 TEST 8 CODE # 3 STAY 6 BYPASS 9 CHIME READY 1 OFF ON OFF 4 MAX

More information

VISTA-20HWSE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM

VISTA-20HWSE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM VISTA-20HWSE 2-PARTITIONED SECURITY SYSTEM INSTALLATION INSTRUCTIONS Principal changes between the VISTA-20HWSE and the former VISTA-20HW are indicated by margin lines. N7526-2V2 8/97 RECOMMENDATIONS FOR

More information

DS7400Xi Addressable Control/ Communicator

DS7400Xi Addressable Control/ Communicator DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems

More information

&RPPHUFLDO%XUJODU\ ,QVWDOODWLRQDQG6HWXS*XLGH 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 3 STAY 1 OFF 6BYPASS 5 TEST 4 MAX 9 CHIME 7 INSTANT OFF 2 AWAY

&RPPHUFLDO%XUJODU\ ,QVWDOODWLRQDQG6HWXS*XLGH 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 3 STAY 1 OFF 6BYPASS 5 TEST 4 MAX 9 CHIME 7 INSTANT OFF 2 AWAY ARMED 7 INSTANT 8 CODE 9,67$%3 9,67$%3 &RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ,QVWDOODWLRQDQG6HWXS*XLGH ARMED READY 1 OFF 4 MAX 7 INSTANT READY 0 2 AWAY 5 TEST 8 CODE # 3 STAY 6 BYPASS

More information

VISTA-100. COMMERCIAL FIRE AND BURGLARY PARTITIONED SECURITY SYSTEM with SCHEDULING. INSTALLATION INSTRUCTIONS and PROGRAMMING GUIDE N6019-2V1 1/98

VISTA-100. COMMERCIAL FIRE AND BURGLARY PARTITIONED SECURITY SYSTEM with SCHEDULING. INSTALLATION INSTRUCTIONS and PROGRAMMING GUIDE N6019-2V1 1/98 VISTA-100 COMMERCIAL FIRE AND BURGLARY PARTITIONED SECURITY SYSTEM with SCHEDULING INSTALLATION INSTRUCTIONS and PROGRAMMING GUIDE N6019-2V1 1/98 Recommendations for Proper Protection The Following Recommendations

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

Installation and Setup Guide

Installation and Setup Guide IntelliPath TM Series 4G GSM Communicator Auto-selects Optimum GSM path 2G, 3G, or 4G GSMV4G / GSMVCN4G supports two-way voice Installation and Setup Guide 800-11119 1/12 Rev. B Table of Contents SECTION

More information

VISTA-128FB. Installation and Setup Guide. Commercial Fire & Burglary Partitioned Security System with Scheduling

VISTA-128FB. Installation and Setup Guide. Commercial Fire & Burglary Partitioned Security System with Scheduling Features Q.E.D. programming for quick enrollment of devices. VISTA-128FB Commercial Fire & Burglary Partitioned Security System with Scheduling Installation and Setup Guide N8988 5/98 ii Recommendations

More information

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Installation and Setup Guide K5305-1V6 7/08 Rev. A RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations

More information

9,67$&1 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH K3892V1 4/00

9,67$&1 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH K3892V1 4/00 9,67$ 9,67$&1 6HFXULW\6\VWHP,QVWDOODWLRQDQG6HWXS*XLGH * K3892V1 4/00 VISTA-15/VISTA-15CN Installation & Setup Guide ii RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the location

More information

9,67$39,67$3&1 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH K /01 1 OFF 4 MAX OFF 7 INSTANT 9 CHIME READY

9,67$39,67$3&1 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH K /01 1 OFF 4 MAX OFF 7 INSTANT 9 CHIME READY ARMED 7 INSTANT 8 CODE 9,67$39,67$3&1 9,67$39,67$3&1 6HFXULW\6\VWHPV,QVWDOODWLRQDQG6HW8S*XLGH ARMED READY 1 OFF 4 MAX 7 INSTANT READY 0 2 AWAY 5 TEST 8 CODE # 3 STAY 6 BYPASS 9 CHIME READY 1 OFF ON OFF

More information

&RPPHU LDO)LUHDQG%XUJODU\

&RPPHU LDO)LUHDQG%XUJODU\ 9,67$)% &RPPHU LDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6H XULW\6\VWHP ZLWK6 KHGXOLQJ,QVWDOODWLRQDQG6HWXS*XLGH FIRE FIRE * PULL N8988V2 8/00 ii Table of Contents List of Figures... viii Conventions Used in This Manual...ix

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1 1.1 PC5015 Specifications System Introduction S E C T I O N 1 Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

VISTA-128B. Installation and Setup Guide. Commercial Burglary. Partitioned Security System. with Scheduling K3271 7/98

VISTA-128B. Installation and Setup Guide. Commercial Burglary. Partitioned Security System. with Scheduling K3271 7/98 VISTA-128B Commercial Burglary Partitioned Security System with Scheduling Installation and Setup Guide K3271 7/98 ADDENDUM TO: VISTA-128B INSTALLATION INSTRUCTIONS This Installation Instruction Addendum

More information

4286/4500 Voice Module Set up and Troubleshooting

4286/4500 Voice Module Set up and Troubleshooting 4286/4500 Voice Module Set up and Troubleshooting In this document we will discuss the following: 1. Pre-Installation Notes 2. The Wiring 3. System Programming 4. 4286 1 st Time Accessing and Programming

More information

&RPPHUFLDO)LUHDQG%XUJODU\

&RPPHUFLDO)LUHDQG%XUJODU\ ARMED 7 INSTANT 8 CODE 9,67$)%3 9,67$)%3 &RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ,QVWDOODWLRQDQG6HWXS*XLGH ARMED READY 1 OFF 4 MAX 7 INSTANT READY 0 2 AWAY 5 TEST 8 CODE # 3 STAY

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

6HFXULW\6\VWHP,QVWDOODWLRQDQG6HW8S*XLGH N7227AUV2 12/99

6HFXULW\6\VWHP,QVWDOODWLRQDQG6HW8S*XLGH N7227AUV2 12/99 9,67$6(D 6HFXULW\6\VWHP,QVWDOODWLRQDQG6HW8S*XLGH * N7227AUV2 12/99 Table of Contents Section 1. GENERAL DESCRIPTION...1-1 About the VISTA-10SEa...1-1 Basic Wired Zones...1-1 Optional Expansion Zones...1-1

More information

Installation and Set-Up Guide

Installation and Set-Up Guide ADEMCO Vista-12D Installation and Set-Up Guide This control complies with EN50131-1 K10022V1 4/05 Rev. A Installation and Setup Guide ii Table Of Contents Features and Installation Highlights...1-1 Capabilities...

More information

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher IMPORTANT WARNING:This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal

More information

)$&3 ,QVWDOODWLRQDQG6HW8S*XLGH K5305-5V1 8/02 OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 BYPASS MAX INSTANT READY ARMED READY

)$&3 ,QVWDOODWLRQDQG6HW8S*XLGH K5305-5V1 8/02 OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 BYPASS MAX INSTANT READY ARMED READY MAX INSTANT READY R BYPASS AWAY ARMED READY 1 OFF MAX INSTANT READY R 2 AWAY 3 STAY BYPASS R )$&36 )$&3 6HFXULW\6\VWHPV,QVWDOODWLRQDQG6HW8S*XLGH ARMED READY A B C D 7 4 1 OFF FA260 2 AWAY 5 TEST 8 CODE

More information

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68) F A 1 7 0 0 c Testing the System Battery Test When AC power is present, the FA1700C runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery

More information

Now with 16.5 VAC Transformer Requires Compass Version A (or higher) for GSM Downloading

Now with 16.5 VAC Transformer Requires Compass Version A (or higher) for GSM Downloading AlarmNet 7845GSM/7845GSMCN Digital Cellular Communicator With Remote Services Installation and Setup Guide Now with 16.5 VAC Transformer Requires Compass Version 1.5.8.54A (or higher) for GSM Downloading

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

System Introduction. 1.1 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1 System Introduction S E C T I O N 1 1.1 Specifications Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master

More information

VISTA-20SE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM.

VISTA-20SE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM. VISTA-20SE 2-PARTITIONED SECURITY SYSTEM INSTALLATION INSTRUCTIONS Principal changes between the VISTA-20SE and the former VISTA-20 are indicated by margin lines. N7526V4 8/97 RECOMMENDATIONS FOR PROPER

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

The OmniPro II EN50131 and PD6662 Compliant Controller

The OmniPro II EN50131 and PD6662 Compliant Controller The OmniPro II EN50131 and PD6662 Compliant Controller omni APPLICATION The OmniPro II is the flagship security & automation controller. Designed for large residential and commercial installations, the

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

V2 1/13 Rev C

V2 1/13 Rev C VISTA-128BPT/VISTA-250BPT/ VISTA-128BPTSIA Commercial Burglary Partitioned Security System With Scheduling Installation and Setup Guide 800-06903V2 1/13 Rev C Table of Contents VISTA-128BPT/VISTA-250BPT/...

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

FBII Security System. Installation and Setup Guide. Version 2.0. N9938V4 8/06 Rev. A

FBII Security System. Installation and Setup Guide. Version 2.0. N9938V4 8/06 Rev. A FBII Security System OMNI -848 OMNI -848EU Version 2.0 Installation and Setup Guide N9938V4 8/06 Rev. A THANK YOU for your purchase of the OMNI -848 Security System. The purpose of this manual is to give

More information

The Omni LTe EN50131 and PD6662 Compliant Controller

The Omni LTe EN50131 and PD6662 Compliant Controller The Omni LTe EN50131 and PD6662 Compliant Controller omni APPLICATION The Omni LTe is a full sized security and automation system with flash memory and five serial ports, as well as an Ethernet port for

More information

VISTA-10SE. Security System. Installation Instructions Installation Instructions Installation Instructions

VISTA-10SE. Security System. Installation Instructions Installation Instructions Installation Instructions Security System VISTA-10SE THIS ISSUE INCLUDES THE NEW QED (QUICK ENROLLMENT OF DEVICES) PROCEDURE FOR 5800 SERIES TRANSMITTERS Installation Instructions Installation Instructions Installation Instructions

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

FA130CP. Installation and Set-Up Guide. K0735-1V1 4/04 Rev. A OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 READY R BYPASS MAX

FA130CP. Installation and Set-Up Guide. K0735-1V1 4/04 Rev. A OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 READY R BYPASS MAX MAX INSTANT READY R BYPASS AWAY ARMED READY 1 OFF MAX INSTANT READY R 2 AWAY 3 STAY BYPASS FA130CP Security System Installation and Set-Up Guide ARMED READY A B C D 7 4 1 OFF FA260 2 AWAY 5 TEST 8 CODE

More information

LYNX ,QVWDOODWLRQ,QVWUXFWLRQV. ALPHA DRAFT. June 5, 1998 N8889 5/98 OFF AWAY STAY AUX

LYNX ,QVWDOODWLRQ,QVWUXFWLRQV.  ALPHA DRAFT. June 5, 1998 N8889 5/98 OFF AWAY STAY AUX LYNX Security System,QVWDOODWLRQ,QVWUXFWLRQV ALPHA DRAFT June 5, 1998 OFF AWAY STAY AUX N8889 5/98 RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations For The Location Of Fire And Burglary

More information

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION...2 STANDARD AND OPTIONAL PARTS LIST...2 FEATURE DEFINITIONS...3 TERMINAL DRAWING AND SPECIAL NOTES...4

More information

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Installation and Operation Guide K5305-1V10 3/15 Rev. A RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

Vista-128FB System Design Sheet

Vista-128FB System Design Sheet Vista-128FB System Design Sheet FIRE DETECTION SPRINKLER SUPERVISION INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-128FB (Eight Hardwired Zones,

More information

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030 All-In-One Wireless Security System V1.3 Programming Guide Model # MG-6060 / MG-6030 Table of Contents Things You Should Know... 2 About This Programming Guide... 2 Conventions... 2 Installer Code (Default:

More information

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability.

More information

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems Installation and Setup Guide K0735V5 4/09 Rev. A RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary

More information

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 1.0 General 1.1 Manufacturer Manufacturer of the Fire Alarm Control Panel (FACP) equipment shall be: Digital Monitoring Products, Incorporated 2500 N.

More information

WIRELESS CONTROLS & DETECTORS

WIRELESS CONTROLS & DETECTORS WIRELESS CONTROLS & DETECTORS WLS908 Panic Pendant Press 2 buttons for 2 seconds to initiate a panic alarm Water-resistant Pendant test function Supervised for low battery Each pendant is a wireless zone

More information

Security Systems. Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN. Installation and Set-Up Guide

Security Systems. Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN. Installation and Set-Up Guide ARMED READY OFF INSTANT READY AWAY TEST CODE STAY BYPASS CHIME ARMED READY OFF INSTANT READY AWAY TEST CODE STAY BYPASS CHIME Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN Security Systems

More information

Booster Power Supply Manual

Booster Power Supply Manual Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation

More information

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E... 5$1*(5( DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS General Description... 2 Standard and Optional Parts List... 2 Feature Definitions... 3 Comments about the 8600E... 4 Terminal

More information

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging 1.1 Specifications System Introduction S E C T I O N 1 Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master,

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: -961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

VISTA-40. Installation and Setup Guide. 2-Partition Security System N7001V4 7/98

VISTA-40. Installation and Setup Guide. 2-Partition Security System N7001V4 7/98 VISTA-40 2-Partition Security System Installation and Setup Guide N7001V4 7/98 ADDENDUM TO: VISTA-40, VISTA-50P, VISTA-50PUL INSTALLATION INSTRUCTIONS This Installation Instruction Addendum covers changes

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

The Omni IIe EN50131 and PD6662 Compliant Controller

The Omni IIe EN50131 and PD6662 Compliant Controller The Omni IIe EN50131 and PD6662 Compliant Controller omni APPLICATION Omni IIe is an ideal and economical choice for homes and small businesses. The system provides enhanced comfort, safety, convenience

More information

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

If you want to. grow your business expand your. expectations.

If you want to. grow your business expand your. expectations. If you want to grow your business......expand your expectations. Expect more with Honeywell. Honeywell s innovative line of commercial products provide you with more of what you want the power, capacity

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor

More information

ADEMCO LYNXR Series Security Systems

ADEMCO LYNXR Series Security Systems ADEMCO LYNXR Series Security Systems LYNXR/LYNXR24 and LYNXR-EN Installation and Setup Guide ARMED READY OFF ESCAPE AWAY ADD STAY RECORD LIGHTS ON 1 2 3 VOLUME 4 5 6 TEST 7 8 9 PLAY BYPASS DELETE AUX LIGHTS

More information

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their HONEYWELL SECURITY & CUSTOM ELECTRONICS Wireless Products Honeywell s quick-install wireless devices, with their rock-solid stability and long battery life, were built with the security professional in

More information

Installation Instructions

Installation Instructions g 466-2339A October 2009 2009 GE Security, Inc. Introduction This is the GE. Installations should only be done by trained professionals. Use this document to install the system with default settings that

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

System Programming Guide

System Programming Guide & System Programming Guide Software Versions 4.4 (728ULT) and 4.1 (738ULT) Installer Code (Default - 728 Ultra: 282828; 738 Ultra: 383838) Full access to programming, except user access codes (PINs). No

More information

KT-100 Door Controller

KT-100 Door Controller WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information