1 Page 1 of 19 Committee Input No. 14-NFPA [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new Chapter 18 and would cover indoor membrane enclosures. Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Mon Mar 18 14:24:39 EDT 2013 Committee Statement

2 Page 2 of 19 Committee The origination of this proposal came from the current use of these Statement: enclosures in the Marina Industry. Marina spray painting is occurring in the US and throughout the world in temporary membrane enclosures outdoors and within buildings. There is a desire and need to establish a standardized practice for fire safety officials and users. The outdoor provisions being put forth in a new chapter for safe membrane enclosure spray painting contains a set of checks and balances that are greater than what is normally found in a spray paint booth that contains a suppression system. The intent is to mitigate the potential for fire. The challenge is the placement of these outdoor enclosures with all the checks and balances present, INSIDE of a building. They must also insure that the building is not at greater risk in a fire event. The presence of fire sprinklers in the building to protect the building and the commodities being placed within it must be capable of reaching within the membrane enclosure to contain and possibly extinguish a fire. Testing of a membrane enclosure using a crib fire and fire sprinklers outside the enclosure were completed and recorded. A video of this testing can be found at The test was modeled around the marine industry use of fire resistive shrink wrap material for an enclosure with fire sprinklers designed for Extra Hazard Group 2. A small TG of NFPA 13 members did a preliminary review of the proposal for indoor membrane enclosures within buildings with sprinklers and was concerned that the membrane would create an obstruction to sprinkler discharge. The sprinkler task group indicated that while the small scale test showing the behavior of the membrane under test conditions was a start, that additional full scale testing may be needed to look at factors such as ceiling and sprinkler height, clearance between the membrane and sprinkler system and delivered density, ignition locations, obstructions under the membrane and validation or justification of the fire source. The Committee and membrane task group will continue working with the NFPA 13 committee on the issues of concern. Response Message: Ballot Results This item has not been balloted

3 This additional material would be added to the First Revision 13, new Chapter 18, to cover indoor membrane enclosures Temporary membrane enclosures for spray painting boats in marina s shall be permitted to be installed in buildings provided all of the requirements of this chapter are complied with in design, installation, and conduct of spray paint operations within the enclosure Only shrink wrap material passing NFPA 701 Test 2 requirements shall be used for spray painting boats in marina buildings * Buildings in which temporary membrane enclosures are installed shall have a minimum of 25% of the exterior walls open and unobstructed. A The openness requirement serves two purposes. First it helps to insure that any flammable vapors released as a part of spray painting are readily diluted while reducing the possibility of concentrations of flammable vapors in the building. Second, the openness requirement gives better access to responding firefighters in the event of a fire emergency Buildings in which temporary membrane enclosures are installed shall be provided with Automatic Sprinkler Systems in accordance with Section The automatic sprinkler system shall be designed for Extra Hazard (Group 2) occupancies, as defined in NFPA 13, Standard for the installation of Sprinkler Systems.

4 Page 3 of 19 Committee Input No. 95-NFPA [ Global Input ] Add the drawing in new Chapter 18 to go along with FR 13. Supplemental Information File Name Open 33FCf18-7.pdf Description Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu May 16 10:41:09 EDT 2013 Committee Statement Committee Statement: Response Message: The committee is considering adding the attached drawing to go with new Chapter 18 on membrane enclosures. Ballot Results This item has not been balloted

5 Extent of the Class I, Division 2 Membrane enclosure (support structure not shown) 1525 mm (5 ft) Ventilation exhaust Workpiece Class I, Division 1, within the membrane enclosure Air intake 1525 mm (5 ft) PLAN VIEW Extent of the Class I, Division mm (5 ft) Class I, Division mm (5 ft) Membrane enclosure (support structure not shown) Ventilation exhaust Workpiece Air intake ELEVATION

6 Page 4 of 19 Committee Input No. 88-NFPA [ Section No ] Combustible Liquid. Any liquid that has a closedcup closed-cup flash point at or above 100 F (37.8 C), as determined by the test procedures and apparatus set forth in 1 Section [ of NFPA 30]. Combustible liquids are classified as Class II or Class III according to Section 4.3 of NFPA 30 as follows: (1) Class II Liquid any liquid that has a flash point at or above 100 F (37.8 C) and below 140 F (60 C); (2) Class IIIA any Class III Liquid- Any liquid that has a flash point at or above 140 F (60 C) (a) Class IIIA Liquid Any liquid that has a flash point at or above 140 F (60 C), but below 200 F (93 C); (3b)Class IIIB Liquid any Any liquid that has a flash point at or above 200 F (93 C). [30, ] Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu May 16 08:59:12 EDT 2013 Committee Statement Committee Statement: Response Message: The definition has been slightly revised to match that in NFPA 30. This definition will also be correlated with NFPA 34 so that both documents have the same definitions. Ballot Results This item has not been balloted

7 Page 5 of 19 Committee Input No. 89-NFPA [ Section No ] Flammable Liquid. Any liquid that has a closed-cup flash point below 100 F (37.8 C), as determined by the test procedures and apparatus set forth in 1 Section [ of NFPA 30 ]. Flammable liquids are classified as Class I as follows: Class ILiquid any liquid that has a closed-cup flash point below 100 F (37.8 C) and a Reid vapor pressure not exceeding 40 psia ( mm Hg) at 100 F that does not exceed an absolute pressure of 40 psi (276 kpa) at 100 F (37.8 C 8 C ), as determined by ASTM D 323, Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method). Class I Flammable liquids are further classified as follows: subclassified in accordance with the following: (1) Class IA liquids Liquids those liquids that have flash points Any liquid that has a flash point below 73 F (22.8 C) and a boiling points point below 100 F (37.8 C); (2) Class IB liquids those liquids that have flash points Any liquid that has a flash point below 73 F (22.8 C) and a boiling points point at or above 100 F (37.8 C); (3) Class IC liquids those liquids that have flash points Any liquid that has a flash point at or above 73 F (22.8 C), but below 100 F (37.8 C). [30, ] Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu May 16 09:18:31 EDT 2013 Committee Statement Committee Statement: Response Message: The definition has been slightly revised to match that in NFPA 30. This definition will also be correlated with NFPA 34 so that both documents have the same definitions. Ballot Results This item has not been balloted

8 Page 6 of 19 Committee Input No. 90-NFPA [ Section No ] Electrical wiring and utilization equipment located outside, but within 6100 mm (20 ft) horizontally and 3050 mm (10 ft) vertically, of an unenclosed spray area and not separated from the spray area by partitions extending to the boundaries of the area designated as Division 2, Zone 2; or Zone 22 in Figure shall be suitable for Class I, Division 2; Class I, Zone 2; Class II, Division 2; or Zone 22 locations, whichever is applicable. Figure Electrical Area Classification for Unenclosed Spray Areas. Supplemental Information File Name Open 33FCf pdf Description Submitter Information Verification

9 Page 7 of 19 Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu May 16 10:11:50 EDT 2013 Committee Statement Committee Statement: Response Message: Ballot Results This item has not been balloted Committee is considering revising drawings as attached. Hard lines removed.

10 Spray area 6100 mm (20 ft) TOP (PLAN) Roof 3050 mm (10 ft) Spray area FRONT (ELEVATION) Class I, Division 1; Class I, Zone 1; Class II, Division 1; or Zone 21 Class I, Division 2; Class I, Zone 2; Class II, Division 2; or Zone 22

11 Page 8 of 19 Committee Input No. 91-NFPA [ Section No ] If spray application operations are conducted within a closed-top, open-face or open-front booth or room, as shown in Figure 6.5.2, any electrical wiring or utilization equipment located outside the booth or room but within 915 mm (3 ft) of any opening shall be suitable for Class I, Division 2; Class I, Zone 2; Class II, Division 2; or Zone 22 locations, whichever is applicable. Figure Class I, Division 2; Class I, Zone 2; Class II, Division 2; or Zone 22 Locations Adjacent to an Open-Face or Open-Front Spray Booth or Spray Room. Supplemental Information File Name Open 33FCf pdf Description Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu May 16 10:13:35 EDT 2013 Committee Statement Committee Statement: Committee is considering revising drawing as attached. Response Message: Ballot Results This item has not been balloted

12 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius Conveyor opening Open face

13 Page 9 of 19 Committee Input No. 92-NFPA [ Section No ] If spray application operations are confined to an enclosed spray booth or room, electrical area classification shall be as follows: (1) The area within 915 mm (3 ft) of any opening shall be classified as Class I, Division 2; Class I, Zone 2; Class II, Division 2; or Zone 22 locations, whichever is applicable, as shown in Figure (2) Where exhaust air is recirculated and all requirements of Section 7.5 are met, both of the following shall apply: (a) (b) The interior of any recirculation path from the secondary particulate filters up to and including the air supply plenum shall be classified as Class I, Division 2; Class I, Zone 2; Class II, Division 2; or Zone 22 locations, whichever is applicable. The interior of fresh air supply ducts shall be unclassified. (3) Where exhaust air is not recirculated, the interior of fresh air supply ducts and fresh air supply plenums shall be unclassified. Figure Class I, Division 2; Class I, Zone 2; Class II, Division 2; or Zone 22 Locations Adjacent to an Enclosed Spray Booth or Spray Room. Supplemental Information File Name Open 33FCf06-5-4_version1.pdf Open 33FCf06-5-4_version2.pdf Description Submitter Information Verification

14 Page 10 of 19 Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu May 16 10:16:48 EDT 2013 Committee Statement Committee Statement: Committee is considering revising drawing as attached. Response Message: Ballot Results This item has not been balloted

15 915 mm (3 ft) radius Extent of Class I, Division 2; Class I, Zone 2; Class II, Division 2; or Zone 22 area 915 mm (3 ft) radius Enclosed spray booth or room (Class I, Division 1; Class I, Zone 1; Class II, Division 1; or Zone 21 within) PLAN VIEW AT CEILING LEVEL 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius ELEVATION

16 915 mm (3 ft) radius Extent of Class I, Division 2; Class I, Zone 2; Class II, Division 2; or Zone 22 area 915 mm (3 ft) radius Enclosed spray booth or room (Class I, Division 1; Class I, Zone 1; Class II, Division 1; or Zone 21 within) PLAN VIEW AT CEILING LEVEL 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius 915 mm (3 ft) radius ELEVATION

17 Page 11 of 19 Committee Input No. 93-NFPA [ Section No ] Electrical wiring and utilization equipment installed in these areas shall be suitable for the location, as shown in Figure Figure Electrical Area Classification for Class I Liquid Operations Around Open Containers, Supply Containers, Waste Containers, Spray Gun Cleaners, and Solvent Distillation Units. Supplemental Information File Name Description 33FCf _version1.pdf Version 1 33FCf version2.pdf Version 2 Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu May 16 10:18:52 EDT 2013 Committee Statement Committee Statement: Committee is considering revising drawing as attached. Response Message: Ballot Results This item has not been balloted

18 610 mm (2 ft) 915 mm (3 ft) 460 mm (18 in.) 3050 mm (10 ft) Class I, Division 1 or Zone 0 (e.g., vapor space in container) Class I, Division 1 or Zone 1 Class I, Division 2 or Zone mm (10 ft) Pit or trench

19 610 mm (2 ft) 915 mm (3 ft) 460 mm (18 in.) 3050 mm (10 ft) Class I, Division 1 or Zone 0 (e.g., vapor space in container) Class I, Division 1 or Zone 1 Class I, Division 2 or Zone mm (10 ft) Pit or trench

20 Page 12 of 19 Committee Input No. 38-NFPA [ Section No ] The automatic fire protection system shall be permitted to be, and shall be installed in accordance with, any of the following: (1) An automatic water sprinkler system that meets all applicable requirements of NFPA 13, Standard for the Installation of Sprinkler Systems (2) An automatic foam water sprinkler system that meets all applicable requirements of NFPA 16, Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems (3) A carbon dioxide extinguishing system that meets all applicable requirements of NFPA 12, Standard on Carbon Dioxide Extinguishing Systems (4) A dry chemical extinguishing system that meets all applicable requirements of NFPA 17, Standard for Dry Chemical Extinguishing Systems (5) A gaseous agent extinguishing system that meets all applicable requirements of NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems (6) A water mist or hybrid water mist fire protection system that meets the applicable requirements of NFPA 750, Standard on Water Mist Fire Protection Systems. Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Tue Mar 19 21:51:41 EDT 2013 Committee Statement

21 Page 13 of 19 Committee Statement: NFPA 750 is currently under revision. The committee is considering adding water mist and hybrid water mist fire protection systems into applicable sections of NFPA 33 however there are several concerns that should be addressed. Water mist systems are currently not listed for use in spray booths although they are listed for use in occupancies similar to mixing rooms. The committee also decided there was a potential conflict with NFPA 750 and the term "hybrid water mist" as suggested in Public inputs 78, 76, 85, and 77. Response Message: Public Input No. 76-NFPA [Section No ] Ballot Results This item has not been balloted

22 Page 14 of 19 Committee Input No. 35-NFPA [ New Section after ] 9.9 Water Supply 9.9.1? The water supply shall be sufficient to supply all sprinklers likely to open in any one fire incident without depleting the available water for use in hose streams ? Where sprinklers are installed to protect spray areas and mixing rooms only, water shall be permitted to be supplied from domestic water systems, provided the domestic supply can meet the demand for the design criteria of Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Tue Mar 19 14:07:09 EDT 2013 Committee Statement Committee Statement: Response Message: The committee will have a task group review water supply concerns within NFPA 33 and will place all existing requirements (9.4.3 and 9.4.4) into a new section 9.9 to be added. In addition the task group is focusing on including requirements for interconnected water based protection systems. The task group will address concerns raised in Public Inputs 19 and 20. Ballot Results This item has not been balloted

23 Page 15 of 19 Committee Input No. 40-NFPA [ New Section after ] Add a new section 9.10 after the new section 9.9 using attached material. Supplemental Information File Name CIChapter9.10.docx Description This is a committee input to add a section 9.10 after 9.9 (added this revision). Please use inserted text. Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Tue Mar 19 23:05:50 EDT 2013 Committee Statement Committee Statement: Response Message: The committee puts forth the following language to solicit public input to further develop new language to address protection for types of filtration systems not previously addressed by the standard. This also addresses PI 79. Ballot Results This item has not been balloted

24 Create CI 9.10 Protection for Dry Particulate Scrubbers The scrubbing material shall be non-combustible and the concentration in the scrubber shall be maintained that in combination with the paint collected the mixture shall be non-combustible Where the filtration media is combustible, the filtration media shall be protected by an approved fire protection system both upstream and downstream The automatic fire protection system shall be permitted to be, and shall be installed in accordance with, any of the protection systems described in Access for inspection and cleaning of sprinklers shall be provided Sprinklers shall be protected against overspray residue and the dry particulate, either by location or covering, so that they will operate quickly in event of fire Sprinklers shall be permitted to be covered only by cellophane bags having a thickness of 0.08 mm (0.003 in.) or less or by thin paper bags. These coverings shall be replaced frequently so that heavy deposits of residue do not accumulate Sprinklers that have been painted or coated by overspray or residues shall be replaced with new sprinklers The scrubber shall be designed to direct the flow from the fire-extinguishing system to an approved location or shall be designed to contain the flow for a period of 20 minutes Interlocks. In addition to the requirements of 9.2.1, activation of the automatic fire protection system shall automatically accomplish all of the following: (1) Shut off all compressed air to the filter cleaning system (2) Stop the dry particulate material delivery and removal system 9.11 Protection for Electrostatic Precipitator Scrubbers (Reserved).

25 Page 16 of 19 Committee Input No. 39-NFPA [ Section No ] Automated liquid electrostatic spray application equipment that is unlisted shall be protected further by the following: (1) In addition to meeting the requirements in 9.8.1, the optical flame detection system shall also activate one of the following over each zone in which fire has been detected: (2) An open head deluge system designed to discharge a minimum density of 24.4 mm/min (0.6 gpm/ft 2 ) (3) A carbon dioxide extinguishing system (4) A dry chemical extinguishing system (5) A gaseous agent extinguishing system (6) A water mist or hybrid water mist fire protection system (7) Manual activation stations shall be installed. At least one such station shall be within ready access of operating personnel. If access to this station is likely to involve exposure to danger, an additional station shall be located adjacent to an exit from the area. These devices shall activate the fire protection system as specified in 9.8.2(1) and accomplish the requirements of and (2). (8) A wet pipe sprinkler system shall also be provided throughout the spray booth. This system shall meet all the applicable requirements of NFPA 13, Standard for the Installation of Sprinkler Systems for Extra Hazard (Group 2) occupancies. (9) Automatic electrostatic equipment enclosures inside the booth systems shall be protected with an approved automatic fire protection system. Activation of this system shall automatically accomplish the requirements of and (2). Submitter Information Verification

26 Page 17 of 19 Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Tue Mar 19 22:00:02 EDT 2013 Committee Statement Committee Statement: NFPA 750 is currently under revision. The committee is considering adding water mist and hybrid water mist fire protection systems into applicable sections of NFPA 33 however there are several concerns that should be addressed. Water mist systems are currently not listed for use in spray booths although they are listed for use in occupancies similar to mixing rooms. The committee also decided there was a potential conflict with NFPA 750 and the term "hybrid water mist" as suggested in Public inputs 78, 76, 85, and 77. Response Message: Public Input No. 77-NFPA [Section No ] Ballot Results This item has not been balloted

27 Page 18 of 19 Committee Input No. 87-NFPA [ Section No. C.2.1 ] C.2.1 Minimum Explosive Concentration (MEC). Specifications usually available from the manufacturers of coating powders can be used to establish the MEC. If that specification is not available (or if the system is projected for use with a variety of coating powders), a figure of g/m 3 (30 15 oz/1000 ft 3 ) can be used. This is considered representative of the lowest MEC to be found among common coating powders. (See Table C.2.1.) Table C.2.1 Representative Test Data on Specific Powders Type Sample No. MEC Autoignition Temperature g/m 3 oz/1000 ft 3 C F Epoxy Polyester * Polyolefin *Same as Sample 1 but with metallic component in pigment. Note: Data determined using FM Global 3.7-Liter 20 liter Kuhner Dust Explosion Test Apparatus, a modified Hartmann Test Apparatus.. Testing in accordance with ASTM E Add new reference : ASTM E (2007) Standard Test Method for Minimum Explosible Concentration of Combustible Dusts Supplemental Information File Name Open Section_C.2.1_and_Table_C.2.1_NFPA_33.docx Description Submitter Information Verification

28 Page 19 of 19 Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu May 16 08:52:30 EDT 2013 Committee Statement Committee Statement: Response Message: Ballot Results In section C.2.1 the generic MEC value of 30 g/m3 is based on the samples tested and displayed in Table C.2.1. A review of FM Global s database of dust samples similar in composition to powder coating materials shows a number of MEC values less than 30 g/m3. Some of the MEC values are as low as 8-10 g/m3. However, not all of the samples in FM Global s database that were reviewed can be directly related to powder coating materials. A value lower than 30 g/m3 is probably warranted but without updating the information in Table C.2.1 it is uncertain how much lower. A compromise of 15 g/m3 is suggested as a place holder until the values in table C.2.1 can be updated. Table C.2.1 is based on a number of samples tested by FM Global in the 3.7 Liter Hartmann Test Apparatus. The samples tested were a reasonable cross section of the common materials used at the time (prior to 1989). In the intervening years the accepted test method for determining MEC has changed as well as the common powder coating materials. The table should be updated with new samples covering a boarder range of common powder coating materials with their MEC s determined using the current standardized test method (using a 20 liter sphere). FM Global has agreed to undertake the MEC testing for 15 new powder coating samples to replace the existing data points in Table C.2.1. AkzoNobel has agreed to donate the 15 samples to be tested. The testing will be undertaken over the next 6 months. The values in the table will be updated once all the testing has been completed. Once Table C.2.1 has been updated the generic MEC value in section C.2.1 can be set based on the results. This item has not been balloted

29 NFPA [Section C.2.1 & Table C.2.1] C.2.1 Minimum Explosive Concentration (MEC). Specifications usually available from the manufacturers of coating powders can be used to establish the MEC. If that specification is not available (or if the system is projected for use with a variety of coating powders), a figure of g/m 3 (30 15 oz/1000 ft 3 ) can be used. This is considered representative of the lowest MEC to be found among common coating powders. (See Table C.2.1.) Table C.2.1 Representative Test Data on Specific Powders Type Sample No. MEC Autoignition Temperature g/m3 oz/1000 ft3 C F Epoxy Polyester Polyolefin Note: Data determined using FM Global 3.7 Liter Dust Explosion Test Apparatus, a modified Hartmann Test Apparatus 20 Liter Kuhner Dust Explosion Test Apparatus. Testing in accordance with ASTM E Reference to add to Chapter 2: ASTM E (2007) Standard Test Method for Minimum Explosible Concentration of Combustible Dusts Statement of Problem and Substantiation for Public Input In section C.2.1 the generic MEC value of 30 g/m 3 is based on the samples tested and displayed in Table C.2.1. A review of FM Global s database of dust samples similar in composition to powder coating materials shows a number of MEC values less than 30 g/m 3. Some of the MEC values are as low as 8 10 g/m 3. However, not all of the samples in FM Global s database that were reviewed can be directly related to powder coating materials. A value lower than 30 g/m 3 is probably warranted but without updating the information in Table C.2.1 it is uncertain how much lower. A compromise of 15 g/m 3 is suggested as a place holder until the values in table C.2.1 can be updated. Table C.2.1 is based on a number of samples tested by FM Global in the 3.7 Liter Hartmann Test Apparatus. The samples tested were a reasonable cross section of the common materials used at the time (prior to 1989). In the intervening years the accepted test method for determining MEC has changed as well as the common powder coating materials. The table should be updated with new samples covering a boarder range of common powder coating materials with their MEC s determined using the current standardized test method (using a 20 liter sphere). FM Global has agreed to undertake the MEC testing for 15 new powder coating samples to replace the existing data points in Table C.2.1. AkzoNobel has agreed to donate the 15 samples to be tested. The testing will be undertaken over the next 6 months. The values in the table will be updated once all the testing has been completed. Once Table C.2.1 has been updated the generic MEC value in section C.2.1 can be set based on the results. Submitter Information Verification Amy Brown, FM Global

Committee Input No. 60-NFPA [ Sections , ]

Committee Input No. 60-NFPA [ Sections , ] Page 1 of 15 Committee Input No. 60-NFPA 34-2013 [ Sections 3.3.7.1, 3.3.7.2 ] Sections 3.3.7.1, 3.3.7.2 3.3.7.1 Combustible Liquid. A Any liquid that has a closed-cup flash point at or above 100 F (37.8

More information

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials Fire Preven4on Officers Associa4on of Bri4sh Columbia 2013 Annual Seminar Kelowna, Bri4sh Columbia May 9, 2013 NFPA 33 Scope

More information

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY Fire Department HEADQUARTERS 4410 Cathedral Oaks Road Santa Barbara, CA 93110-1042 (805) 681-5500 FAX: (805) 681-5563 Michael W. Dyer Fire Chief County Fire Warden Eric Peterson Deputy Fire Chief CODE

More information

"Spray area" is the term that is used throughout the document. This change is for consistency.

Spray area is the term that is used throughout the document. This change is for consistency. of 78 5/30/2014 2:08 PM Public Comment No. 39-NFPA 33-2013 [ Global Input ] For Chapter 18, replace "spray paint area" with "spray area". "Spray area" is the term that is used throughout the document.

More information

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems FEMA Recommendations are based upon Live Fire Testing of Prep Stations

More information

First Revision No. 1-NFPA [ Chapter 2 ]

First Revision No. 1-NFPA [ Chapter 2 ] First Revision No. 1-NFPA 499-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this recommended practice

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS FEMA RECOMMENDATIONS ARE BASED UPON LIVE FIRE TESTING OF PREP STATIONS

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION FC 1801 GENERAL 1801.1 Scope. This chapter shall govern the design, installation, operation and maintenance of semiconductor fabrication facilities

More information

FLAMMABLE FINISHES CHAPTER 24

FLAMMABLE FINISHES CHAPTER 24 CHAPTER 24 FLAMMABLE FINISHES SECTION 2401 GENERAL 2401.1 Scope. This chapter shall apply to locations or areas where any of the following activities are conducted: 1. The application of flammable finishes

More information

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ]

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ] of 46 11/6/2015 9:21 AM First Revision No. 208-NFPA 30-2015 [ Section No. 9.3.3.1 ] 9.3.3.1 Storage of liquids shall not physically obstruct a means of egress. Submittal Date: Wed Sep 09 18:24:20 EDT 2015

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply with this chapter and the International

More information

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 4-NFPA 214-2013 [ Section No. 4.2 ] 4.2 * Fire Risk Analysis. A fire risk analysis shall be conducted. The following are some of the factors that shall be considered in determining the

More information

First Revision No. 6-NFPA [ Section No. 2.2 ]

First Revision No. 6-NFPA [ Section No. 2.2 ] Page 1 of 18 First Revision No. 6-NFPA 555-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 12, Standard on Carbon

More information

(h) Pesticide Application.

(h) Pesticide Application. Fire Code Cannabis Amendment Section 13.20.066 is added to the Marysville Municipal Code to read in its entirety as follows: 13.20.066 Cannabis Growing, Processing, or Extraction Facilities (a) Application.

More information

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content Based on the 2018 International Fire Code, (IFC ) The International Fire Code (IFC ), establishes minimum regulations for fire safety. This handout will identify important changes in the IFC from 2015

More information

Page 1 of 12 Input No. 62-NFPA 409-2013 [ Section No. 3.3.9 ] 3.3.9 Hangar Building Cluster. A group of buildings with more than one area for the storage and servicing of aircraft and all attached or contiguous

More information

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

Committee Input No. 28-NFPA 13R-2013 [ Global Input ] Page 1 of 6 Committee Input No. 28-NFPA 13R-2013 [ Global Input ] 6.2.2 Outside Dwelling Units. 6.2.2.1 All sprinklers used outside of the dwelling units shall be in accordance with 6.2.2 7.2 and 7.3.

More information

Special Occupancy Requirements

Special Occupancy Requirements Special Occupancy Requirements CHAPTER 2 0 AVIATION FACILITIES CHAPTER 2 1 DRY CLEANING CHAPTER 2 2 COMBUSTIBLE DUST-PRODUCING OPERATIONS Special Occupancies The objective of this module is to make the

More information

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 4-NFPA 496-2014 [ Section No. 5.2.2 ] 5.2.2 Where When the enclosure has been opened or if the protective gas supply has failed to maintain the required positive pressure, the enclosure

More information

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM of 66 5/18/2015 1:01 PM Second Revision No. 36-NFPA 32-2015 [ Detail ] 6.5 Solvents (See Annex C for additional information on solvents) Submittal Date: Tue Mar 17 17:20:03 EDT 2015 Committee Statement:

More information

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS Page 1 of 6 CENTRAL STATE HOSPITAL PLAN SUBJECT: SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS ANNUAL REVIEW MONTH: RESPONSIBLE FOR REVIEW: APRIL CSH SAFETY DIRECTOR LAST REVISION

More information

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] 1.3 Application. 1.3.1 This standard shall apply to all systems for the movement of environmental air in structures that serve the following, except

More information

First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM

First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM of 28 11/18/2016 2:25 PM First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] 1.6 Units and Formulas. 1.6.1 The units of measure in this standard are presented first in U.S. customary units (inch-pound

More information

First Revision No. 15-NFPA [ Chapter 2 ]

First Revision No. 15-NFPA [ Chapter 2 ] Page 1 of 28 First Revision No. 15-NFPA 91-2013 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard

More information

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM 1 of 11 1/18/2016 5:43 PM First Revision No. 2-NFPA 51-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) CGA C-7 Guide to Precautionary Labelling

More information

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ] 8 of 93 11/6/2015 7:41 AM Public Input No. 52-NFPA 30-2015 [ Section No. 21.2 [Excluding any Sub-Sections] ] For the purpose of this chapter, the term in this section shall have the definitions given.

More information

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM 1 of 213 10/20/2016 11:02 AM Committee Input No. 2505-NFPA 72-2016 [ Global Input ] Change the term visible to visual where appropriate Submitter Information Verification Submitter Full Name: SIG-NAS Organization:

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical on Laser Fire Protection Kimberly

More information

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 1-NFPA 36-2013 [ Global Input ] Revise the document to eliminate the use of "Exception" text. The use of "Exception" text is inconsistent with the Manual of Style. Exception text should

More information

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification Second Revision No. 2011-NFPA 101-2016 [ Section No. 14.2.2.2.4 ] 14.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked to prevent unwanted entry

More information

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM First Revision No. 1-NFPA 1403-2015 [ Section No. 1.2.1 ] 1.2.1 The purpose of this standard shall be to provide a process for conducting live fire training evolutions to ensure that they are conducted

More information

Page 1 of 9 First Revision No. 2-NFPA 99B-2012 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 10, Standard for Portable

More information

Working safely with flammable liquids

Working safely with flammable liquids Flammable Liquids Fire hazards are associated with vapors from the flammable liquid. In order for a fire to occur, the following conditions must be met: Concentration of the vapor must be between the upper

More information

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] 4.3.11.5.5 Materials within a raised floor plenum exposed to the airflow shall be (a) noncombustible or (b) exhibit a maximum flame spread index of 25

More information

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Guy R. Colonna, PE Division Manager, NFPA Combustible Dust Symposium Detroit, MI September 20, 2011 1 Objectives

More information

Fluid Collections at the Smithsonian. Michael Kilby, P.E. Joshua Stewart, P.E. Office of Safety, Health & Environmental Management (OSHEM)

Fluid Collections at the Smithsonian. Michael Kilby, P.E. Joshua Stewart, P.E. Office of Safety, Health & Environmental Management (OSHEM) Fluid Collections at the Smithsonian Michael Kilby, P.E. Joshua Stewart, P.E. Office of Safety, Health & Environmental Management (OSHEM) Who We Are OSHEM Authority Having Jurisdiction for Smithsonian

More information

Public Comment No. 3-NFPA [ Chapter 7 ]

Public Comment No. 3-NFPA [ Chapter 7 ] Page 1 of 8 Public Comment No. 3-NFPA 405-2013 [ Chapter 7 ] Chapter 7 ARFF Personnel Safety and Safety Management 7.1 Scope. This chapter identifies the knowledge and skills necessary to ensure ARFF personnel

More information

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement of 35 1/21/2016 7:56 AM First Revision No. 1-NFPA 30A-2015 [ Section No. 1.1.3 ] 1.1.3* This code shall not apply to those motor fuel dispensing facilities where only liquefied petroleum gas (LP-Gas),

More information

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE Developed by the Midwestern Regional Work Group CONTENTS Item 15 Limited area sprinkler systems Item 20 Scope of IFC Ch 7 Item 21 Fire-resistance-rated

More information

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 43 10/20/2015 4:02 PM First Revision No. 2035-NFPA 101-2015 [ Global Input ] To 14.3.4.4.1, add an item (4) to read: (4) Carbon monoxide detectors shall be installed centrally located within occupiable

More information

NFPA 30 FLC-SWC Public Comment Report

NFPA 30 FLC-SWC Public Comment Report of 224 9/6/2016 1:13 PM Public Comment No. 56-NFPA 30-2016 [ Global Input ] These definitions of Protected and Unprotected are intended for inclusion in Sections 9.2, 10.2, 11.2, 13.2 and 16.2. The current

More information

First Revision No NFPA [ Section No ]

First Revision No NFPA [ Section No ] 1 of 58 10/28/2015 10:15 AM First Revision No. 5015-NFPA 5000-2015 [ Section No. 3.3.628.11 ] 3.3.633.11* Parking Structure. A building, structure, or portion thereof used for the parking, storage, or

More information

Identifying and Preventing Dust Fire and Explosion Hazards

Identifying and Preventing Dust Fire and Explosion Hazards Identifying and Preventing Dust Fire and Explosion Hazards Warren Greenfield International Specialty Products Wayne, New Jersey ABSTRACT This paper discusses how International Specialty Products Inc. addresses

More information

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018) M EM O RA N D UM TO: FROM: DATE: SUBJECT: Correlating Committee on Combustible Dusts Yiu Lee, Project Administrator January 27, 2017 NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

More information

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements Module 3 Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements 1 WATER-BASED SUPPRESSION SYSTEMS-PART TWO This module covers: 1. Ohio Building Code requirements and when and why

More information

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

WORKING DRAFT OF COMMITTEE MEETING OUTPUT WORKING DRAFT OF COMMITTEE MEETING OUTPUT CONTENT NOT FINAL SUBJECT TO REVISION PRIOR TO LETTER BALLOT AND PUBLICATION OF SECOND DRAFT REPORT Document: NFPA 221 Revision Cycle: A2014 Meeting Date: 5/20/2013

More information

Public Comment No. 13-NFPA [ Section No ]

Public Comment No. 13-NFPA [ Section No ] Public Comment No. 13-NFPA 30-2013 [ Section No. 2.3.3 ] 2.3.3 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM A 395/A395M, Standard

More information

Flammable Liquids!!!!!

Flammable Liquids!!!!! Sample Written Program For Your Company For Flammable Liquids Provided By: P.O. Box 2136 Slidell, LA 70458 Phone: 985-781-1444 Fax: 985-718-4957 Email: info@se-safety.com Flammable Liquids Purpose Proper

More information

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES Copyright Material PCIC Europe Paper No. PCIC Europe LO-70 Allan Bozek EngWorks, Inc. 1620 49 th Avenue, SW Calgary, AB T2T

More information

Spray Painting and Coating

Spray Painting and Coating Spray Painting and Coating Disclaimer This training material presents very important information. Your organization must do an evaluation of all exposures, applicable codes and regulations, and establish

More information

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification of 4 9/23/2016 10:20 AM Second Revision No. 6501-NFPA 5000-2016 [ Section No. 17.2.2.2.4 ] 17.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked

More information

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION CHAPTER 23.45 Sections LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION 23.45.100 Local amendments to the International Fire Code, 2006 Edition... 2 23.45.102.1 Construction and design provisions...

More information

Committee on NFPA 30A

Committee on NFPA 30A Committee on M E M O R A N D U M TO: FROM: NFPA Technical Committee on Automotive and Marine Service Stations Patti Mucci, Administrative Assistant DATE: February 5, 00 SUBJECT: ROP Letter Ballot The ROP

More information

NFPA 86 Commitee Inputs Page 1 of 45

NFPA 86 Commitee Inputs Page 1 of 45 of 44 1/26/2017 2:28 PM Committee Input No. 102-NFPA 86-2016 [ Global Input ] The Committee is considering language for pre-purge of the work chambers for Class A, Class B and Class C furnaces. This could

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011 1.0 GENERAL: Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011 1.1 PURPOSE -The intent of this guideline is to provide the requirements for the protection

More information

Flammable Liquid Storage

Flammable Liquid Storage Published on UC Davis Safety Services (https://safetyservices.ucdavis.edu) Flammable Liquid Storage SafetyNet #: 523 Properties, Classification, Quantities, Cabinets, Containers and Refrigerators A. Summary

More information

Above Ground Fuel Tank Requirements

Above Ground Fuel Tank Requirements FIRE DEPARTMENT in cooperation with Above Ground Fuel Tank Requirements The purpose of this document is to provide information about general Fire Code requirements for above ground storage within the unincorporated

More information

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical self-closing device

More information

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement Second Revision No. 1-NFPA 1410-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 1500, Standard on Fire Department

More information

Part I Extraction Process Equipment

Part I Extraction Process Equipment 745 West Colfax Avenue Denver, CO 80204 p: 720.913.3474 f: 720.913.3596 www.denvergov.org/fire MARIJUANA EXTRACTION GUIDELINE FOR COMMERCIAL / LICENSED FACILITIES The information contained within this

More information

SAF-BCF SECOND REVISIONS WITH STATEMENTS

SAF-BCF SECOND REVISIONS WITH STATEMENTS Page 196 of 331 32.2.1.3 ] Second Revision No. 153-NFPA 101-2013 [ New Section after 32.2.1.4 Multiple-Level Buildings. For purposes of applying requirements of this chapter that utilize the term level

More information

AIRCRAFT HANGARS, AIRCRAFT MANUFACTURING AND ASSEMBLY FACILITIES, AND PROTECTION OF AIRCRAFT INTERIORS DURING ASSEMBLY.

AIRCRAFT HANGARS, AIRCRAFT MANUFACTURING AND ASSEMBLY FACILITIES, AND PROTECTION OF AIRCRAFT INTERIORS DURING ASSEMBLY. FM Global Property Loss Prevention Data Sheets 7-93 April 2017 Page 1 of 24 AIRCRAFT HANGARS, AIRCRAFT MANUFACTURING AND ASSEMBLY FACILITIES, AND PROTECTION OF AIRCRAFT INTERIORS DURING ASSEMBLY Table

More information

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification Public Comment No. 2-NFPA 73-2014 [ Section No. 4.1.3 ] 4.1.3 Unused Openings. 4.1.3.1 Unused openings, other than those intended for the operation of equipment, those intended for mounting purposes, or

More information

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input of 280 2/6/2015 12:06 PM Public Input No. 1-NFPA 58-2013 [ Global Input ] NOTE: This public input originates from Tentative Interim Amendment 58-14-1 (TIA 1079) issued by the Standards Council on August

More information

Flammable and Combustible Liquids Checklist

Flammable and Combustible Liquids Checklist Flammable and Combustible Liquids Checklist This checklist covers the storage and use of flammable or combustible liquids in drums or other containers not exceeding 60 gallons individual capacity. Dispensing

More information

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches Pulp & Paper Safety Association Safety & Health Conference June 18, 2018 Mike Snyder PE CSP CFPS Executive Vice President,

More information

Page 1 of /11/2016 2:36 PM. First Revision No. 30-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Page 1 of /11/2016 2:36 PM. First Revision No. 30-NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 90 10/11/2016 2:36 PM First Revision No. 30-NFPA 652-2016 [ Global Input ] All instances of Dust Hazard Analysis should be Dust Hazards Analysis. Please change to the plural all throughout Organization:

More information

Page 1 of 10 Second Revision No. 8-NFPA 600-2014 [ Section No. 3.3.17 ] 3.3.17* Incident Management System (IMS). A system that defines the roles and responsibilities to be assumed by responders and the

More information

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement Second Revision No. 20-NFPA 14-2015 [ Section No. 1.4 ] 1.4* Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength,

More information

Laboratories and Hazardous Materials. Company Overview

Laboratories and Hazardous Materials. Company Overview Laboratories and Hazardous Materials Don E. Contois, P.E. Sam Sinapi Company Overview R.W. Sullivan Engineering (RWS) was established in 1945 and currently has 95 employees. RWS is a full service engineering

More information

CHAPTER 7 ALTERATIONS LEVEL

CHAPTER 7 ALTERATIONS LEVEL CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration

More information

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Helicopter Facilities

More information

NFPA 96, 2017 REVIEW SUMMARY

NFPA 96, 2017 REVIEW SUMMARY NFPA 96, 2017 REVIEW SUMMARY 1) NFPA 96 REVISION SUMMARY NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations The 2017 edition adds a new normative annex on mobile

More information

First Revision No. 20-NFPA [ Section No ]

First Revision No. 20-NFPA [ Section No ] of 25 7/15/2015 8:30 AM First Revision No. 20-NFPA 56-2015 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by NFPA

More information

Second Revision No. 3-NFPA [ Section No. 2.3 ]

Second Revision No. 3-NFPA [ Section No. 2.3 ] Second Revision No. 3-NFPA 804-2014 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990. ASME Boiler

More information

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has

More information

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA) PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA) Glossary of Terms Combustible dust: A finely divided combustible particulate solid that presents a flash-fire hazard or explosion hazard when

More information

Report on First Revisions with Statement June 2014 NFPA 101

Report on First Revisions with Statement June 2014 NFPA 101 101 FR7040 SAF-MER (36.1.1.4) 36.1.1.4 The provisions of this chapter shall apply to life safety requirements for all new mercantile buildings. Specific requirements shall apply to suboccupancy groups,

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. When the present code requires certain safety to life requirements for existing buildings, those requirements shall. a. be void b. apply c. be approved d. be grand-fathered 2. The

More information

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour. Everything a firefighter wants to tell a design professional or building code official, in one hour. 1 2 3 1 4 The job of the fire department is to put the wet stuff on the red stuff. 5 Job #1. of the

More information

OBC INDUSTRIAL CLASSIFICATION OBOA ANNUAL MEETING AND TRAINING SESSIONS LONDON ON OCTOBER 4, 2011

OBC INDUSTRIAL CLASSIFICATION OBOA ANNUAL MEETING AND TRAINING SESSIONS LONDON ON OCTOBER 4, 2011 OBC INDUSTRIAL MAJOR OCCUPANCY CLASSIFICATION OBOA ANNUAL MEETING AND TRAINING SESSIONS LONDON ON OCTOBER 4, 2011 Randal Brown & Associates Ltd. 2011 1 PRESENTERS RANDAL BROWN P.ENG., PE, BDS, FSPFE PRESIDENT

More information

Our Statement is not a problem - we are encouraging continuation of the standard as it is written without substantive changes.

Our Statement is not a problem - we are encouraging continuation of the standard as it is written without substantive changes. of 69 10/3/2016 2:09 PM Public Input No. 25-NFPA 652-2016 [ Global Input ] This standard was approved on September 7, 2015, less than one year ago. We believe this standard as written generally provides

More information

Report on First Revisions with Statement June 2014 NFPA 101

Report on First Revisions with Statement June 2014 NFPA 101 101 FR6005 SAF-BCF (32.2.1.1.2) Recommendation: 32.2.1.1.2 Where there are sleeping accommodations for more than 16 residents are provided, the occupancy shall be classified as a large facility in accordance

More information

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010) CHAPTER 1 SCOPE AND ADMINISTRATION 102.7 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 45 47 and such codes and standards shall

More information

BUILDING/FIRE CODE REFERENCES 2006 EDITION

BUILDING/FIRE CODE REFERENCES 2006 EDITION BUILDING/FIRE CODE REFERENCES 2006 EDITION This document provides a cross reference with the International Building Code and NFPA 1/Uniform Fire The IBC references the IFC in 97 Code sections. This document

More information

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT Olof Bekker Pr. Eng. BSc. Eng. BML S.MSAIEE, M.NACE Engineering Manager, Electrical COMMITMENT

More information

3/20/2017. The Impact & Implications of NFPA 652 NFPA s Newest Combustible Dust Standard. Jason Reason. Jason Reason

3/20/2017. The Impact & Implications of NFPA 652 NFPA s Newest Combustible Dust Standard. Jason Reason. Jason Reason The Impact & Implications of NFPA 652 NFPA s Newest Combustible Dust Standard Jason Reason, CIH, CSP, CHMM Senior Vice President / Consultant Jason Reason Education & Certifications B.S. Industrial Hygiene

More information

NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda*

NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda* NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda* NFPA Standards presented for Action Wednesday, June 24, 2015 starting @ 2:00pm: NFPA 33, Standard for Spray Application Using Flammable or

More information

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed.

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed. REQUIREMENT 2. HOT WORK OPERATIONS 1.0 PURPOSE 1.1 To establish a requirement with responsibilities for any hot work operations during all phases of construction, renovation and routine maintenance work

More information

The Science Behind Water Mist Protection of Typical Building Hazards

The Science Behind Water Mist Protection of Typical Building Hazards The Science Behind Water Mist Protection of Typical Building Hazards SUPDET 2014 Zachary Magnone, P.E. Zachary.Magnone@tycofp.com Presentation Goals What is water mist? How does it work? How is it tested

More information

2008 NYC Fire Code. New Laboratory Standards. Operational & Maintenance Provisions effective July 2008

2008 NYC Fire Code. New Laboratory Standards. Operational & Maintenance Provisions effective July 2008 2008 NYC Fire Code New Laboratory Standards Operational & Maintenance Provisions effective July 2008 Design & Certificate of Fitness Requirements Effective July 1, 2009 History The new Fire Code legislation

More information

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM 1 of 14 6/22/2016 3:15 PM Second Revision No. 1-NFPA 17A-2016 [ Section No. 4.3.3 ] 4.3.3 All discharge nozzles shall be provided with caps or other suitable devices to prevent the entrance of grease vapors,

More information

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement Second Revision No. 5501-NFPA 5000-2016 [ New Section after 29.2.1.2 ] 29.2.1.3 Bathtubs, bathtub-shower combinations, and nonemergency showers shall be provided with grab bars in accordance with the provisions

More information

Second Revision No. 14-NFPA [ Global Comment ] Submitter Information Verification. Committee Statement 8/25/ :39 AM

Second Revision No. 14-NFPA [ Global Comment ] Submitter Information Verification. Committee Statement 8/25/ :39 AM of 36 8/25/2015 10:39 AM Second Revision No. 14-NFPA 664-2015 [ Global Comment ] Add the following statement to the begining of Chapter 10 and Chapter 11 - The provisions of this Chapter shall be applied

More information

Making sense of risk Risk engineering. Metalworking operations

Making sense of risk Risk engineering. Metalworking operations Making sense of risk Risk engineering Metalworking operations Metalworking operations Metalworking operations involve the fabrication of ferrous or nonferrous metal products, structural metal products,

More information

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION SECTION FC 1401 GENERAL 1401.1 Scope. This chapter shall govern fire safety measures during the construction, alteration, or demolition

More information