TS93 EMF SERIES. INSPK NO Rev.03/10
|
|
- Jesse Harrison
- 6 years ago
- Views:
Transcription
1 TS93 EMF SERIES 1 Each hold open (HO) unit contains a door closer and track assembly with hold open solenoid. The unit can be connected directly to a fire control panel. 1) Read the entire instruction sheet prior to installation and refer to NFPA 72E. Standards may be obtained from THE NATIONAL FIRE PROTECTION ASSOCIATION, Batterymarch Park, Quincy, MA., ) Reference the unit carton for mounting style and voltage. 3) Prepare door and frame for fasteners using the appropriate template. Mark, drill and tap holes as indicated. If surface wiring is used, omit 7/8" hole for wire access. CAUTION: SEX NUTS ARE REQUIRED FOR ATTACHMENT OF COMPONENTS TO UNREINFORCED DOORS AND TO WOOD OR PLASTIC FACED COMPOSITE TYPE FIRE DOORS, UNLESS AN ALTERNATIVE METHOD IS IDENTIFIED IN THE INDIVIDUAL DOOR MANUFACTURER'S LISTINGS. 2 Attach mounting plate to door, using lower four holes in plate. Use upper four holes for optional mounting. Arrows on plate face the top of the door. (4) METAL DOORS WOOD DOORS TS93T AND TS93DE INS NO. INSPK NO Rev.03/ PAGE 1 of 7 Rev. 03/10
2 3 Attach closer to mounting plate. (8) TS93T AND TS93DE 4 Remove wire access plug according to the installation type. Any access hole can be used for surface wiring installations. Three access wire holes on optional surface wired units only. T & DE (RH) NO TOP PLUG ON PT MOUNTS T & DE (LH) SURFACE WIRING Install track to frame. TS93T and TS93DE Install with wire access plugs toward latch edge of door using (2) 1/4-20 x 2" metal or (2) No. 14 x 2-3/4" wood screws. Route wires from frame through appropriate wire access hole in track, being careful not to pinch wires during installation. (2) (2) CONTINUED NEXT PAGE... INS NO PAGE 2 of 7 Rev. 03/10
3 STEP CONTINUED... Install PT track to soffit with wire access plugs toward hinge. Install with 1/4-20 x /8" metal or No /4" wood and 1/4-20 x 2" metal or No. 14 x 2-3/4" wood screw as shown. Route wires from frame through appropriate wire access hole in track, being careful not to pinch wires during installation. ( DO NOT INSTALL ON HINGE SIDE IN THIS STEP) C HINGE 6 Slide wiring connection cover to allow access to wire connections. Determine power supply and unit voltage type: 24VAC, 24VDC or 120VAC. CAUTION (DO NOT CONNECT 120VAC TO A 24 VOLT UNIT TYPE.) Connect power supply wires to terminal block as shown (Terminal Block can be removed for easier access). Be sure to use ground screw for power supply ground wire when supplying 120VAC. Return wiring connection cover to cover wire connections. CAUTION: Improper voltage to unit, will result in damage to unit and void warranty. All wiring must comply with national, state and local electrical codes. SOLENOID WIRES GROUND SCREW TO U.L. LISTED ALARM CONTROL UNIT OR SMOKE DETECTOR INCOMING POWER CONNECTION WIRE CONNECTION COVER TERMINAL BLOCK THIS CONNECTION IS NOT POLARITY DEPENDENT. 7 ONLY Insert wire connection cover into track, align end cap in end of track. Install remaining screw as shown using 1/4-20 x 2" metal or No. 14 x 2-3/4" wood screw. TO U.L. LISTED ALARM CONTROL UNIT OR SMOKE DETECTOR WIRE CONNECTION COVER INS NO PAGE 3 of 7 Rev. 03/10
4 8 TS93T Attach arm to pinion of closer and secure arm with pinion screw. TS93DE Attach arm to pinion of closer and secure arm with pinion screw. TS93DE Attach arm to pinion of closer. With door in closed position, rotate spindle approximately 11 with wrench and hold in place. Place arm on spindle parallel to door and secure arm with pinion screw Attach arm to slide shoe. Use 3/16 inch hex head wrench. INS NO PAGE 4 of 7 Rev. 03/10
5 10 Adjust sweep, latch and backcheck or delayed action cycles. CAUTION: DO NOT REMOVE VALVES. DECREASE INCREASE A - SWEEP speed from maximum opening to 0. B - LATCH speed from approx. 7 to 0.-(INCREASE ONLY) A B LATCH RANGE SWEEP RANGE TS93 SZ. 1- BACKCHECK (INTENSITY) OR DELAYED ACTION (TIME) A INCREASE DECREASE C - BACKCHECK cushion effect. D - DELAY speed from approx. 120 to 70. BACKCHECK RANGE CAUTION: DO NOT CLOSE VALVE COMPLETELY. DELAY RANGE DELAYED ACTION IS AN OPTIONAL FEATURE. D C TS93 SZ. 6 D C B 11 Adjust spring tension, if required. Closer is normally supplied with minimum spring setting. Clockwise turns increase spring tension. MAXIMUM NUMBER OF TURNS - 18 CAUTION: DO NOT OVERTIGHTEN BARRIER-FREE OPENINGS - Adjust only if more spring tension is required to positively close and latch door. NON-BARRIER-FREE OPENINGS: TS93 SIZE 1- - Adjust according to chart. TS93 SIZE 6 - Adjust only if more spring tension is required to positively close and latch door. ULC LABELED UNITS "ONLY" - INCREASE DECREASE Adjust according to chart. DOOR WIDTH INT. EXT. 2'6" --- 3' 2'6" 3'6" 3' 4' 3'6" FULL TURNS OF SPRING ADJUSTER CLOSER SIZE CLOSER TYPE TS93 SZ. 1- TS93 SZ.6 MAX. DOOR WEIGHT (LBS) SPRING FULL TURNS SIZE OF SPRING ADJUSTER Hold open position is preset at approximately 90. Loosen set screws using 3/32 inch hex wrench slide hold open device for desired position. Retighten set screws securely. HOLD OPEN DEVICE GREATER HOLD OPEN ANGLE LESS HOLD OPEN ANGLE HOLD OPEN SET SCREWS POWER MUST BE SUPPLIED TO RESET POSITION. INS NO PAGE of 7 Rev. 03/10
6 13 Snap cover onto backplate and attach cover caps to closer. COVER CAPS COVER REMOVE TAB REMOVE TAB SPRING ADJ. END VALVE ADJ. END 14 Final Installation and Test. 1) After the installation is completed, recheck all the connections. Then apply power to the units. 2) Open door so slide block engages with the hold open assembly. 3) Advise fire officials prior to testing the unit. 4) Activate the system into alarm so solenoids release and the doors close. ) If the closer is used in conjunction with a dectectored unit, trip the test switch of the main closer dectector as explained in the test procedure for that unit. After a short time delay, the hold open solenoid of both units will release and the doors will closel. Resetting the test switch will allow the units to return to standby. 1 IMPORTANT: THE UNIT MUST BE TESTED AFTER THE INSTALLATION, BY THE END USER, TO ASSURE THAT THE DOOR CLOSER UNITS FUNCTION PROPERLY WHEN THE ALARM SYSTEM IS ACTIVATED. THE ENTIRE SYSTEM MUST ALSO BE TESTED PERIODICALLY AFTER THE INITIAL INSTALLATION TEST, IN CONJUNCTION WITH THE TESTING OF THE FIRE ALARM SYSTEM. THE END USER IS ALOS RESPONSIBLE FOR THE ADJUSTMENTS AND MAINTENANCE TO RETAIN THE SYSTEM IN WORK ORDER 16 OPERATION: NORMAL - The closer unit's solenoid will be energized across a normally closed alarm contact applying, 24VDC, 24VAC or 120VAC power supply based on unit voltage. FIRE ALARM - When the alarm sounds, the alarm contact will open and interrupt current to the solenoid which releases the hold open and allows the door closer to shut the door ELECTRICAL SPECIFICATIONS: Voltage Input - 24VDC +10% - 1% Maximum Input Current - 24VDC 170mA - 24VAC +10% - 1% - 24VAC 170mA - 120VAC +10% - 1% - 120VAC 33mA INS NO PAGE 6 of 7 Rev. 03/10
7 17 Slide wiring connection cover to allow access. Attach bracket and assemble bypass switch. OPTIONAL BYPASS SWITCH TRACK (T) MOUNT: WIRE CONNECTION COVER Determine power supply and unit voltage type: 24VAC, 24VDC or 120VAC. CAUTION (DO NOT CONNECT 120VAC TO A 24 VOLT UNIT TYPE.) Connect power supply wires, one to terminal block one to bypass switch. connect other bypass switch wire to terminal block. (Terminal Block can be removed for easier access). Be sure to use ground screw for power supply ground wire when supplying 120VAC. Return wiring connection cover to cover wire connections. CAUTION: Improper voltage to unit, will result in damage to unit and void warranty. BYPASS SWITCH GROUND SCREW TO U.L. LISTED ALARM CONTROL UNIT OR SMOKE DETECTOR INCOMING POWER CONNECTION All wiring must comply with national, state and local electrical codes. WIRE CONNECTION COVER TERMINAL BLOCK THIS CONNECTION IS NOT POLARITY DEPENDENT. TERMINAL BLOCK 18awg MAX. OPTIONAL BYPASS SWITCH PUSH TRACK (PT) MOUNT: CAUTION: Improper voltage to unit, will result in damage to unit and void warranty. NOTES: All wiring must comply with national, state and local electrical codes. If installing the optional bypass switch, install assembly on the end of the track as shown. Fasten track to door frame with the screws provided. Fasten the end cap assembly with metal or wood screws provided. Connect the switch with wire nuts and slide the cover in place. Place end cap in extension piece and fasten to fame with screw provided. INS NO PAGE 7 of 7 Rev. 03/10
TS93 EMR WITH SMOKE DETECTOR
TS EMR WITH SMOKE GENERAL DESCRIPTION Each TS EMR series unit contains a door closer, hold open electromagnet and smoke detector. The unit can be used as a single installation or as a series of singles
More information8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION
00 EMR SERIES GENERAL DESCRIPTION Each 00 EMR series unit contains a door closer, hold open electromagnet and smoke detector. The unit can be used as a single installation or as a series of singles powered
More informationMODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload
2900 FIREGUARD Electromechanical Closer-Holder Device Models 12-2960, 9-2960 and 2960 Multipoint Hold Open with Rigid Arms Pull (Hinge) Side Installation Instructions CAUTION: FAILURE TO INSTALL OR ADJUST
More informationMANUAL RESET ALARM RELEASE
Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual
More informationMANUAL RESET ALARM RELEASE
Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual
More informationDC300 Rack and pinion door closer with link arm
Rack and pinion door closer with link arm ASSA ABLOY Rack and pinion closer with link arm L190 Certified in compliance with EN 114, size 3-6 Suitable for fire and smoke protection doors For single action
More informationWiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector
Wiring Instructions for the 900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR
More informationMANUAL RESET ALARM RELEASE BOX
MANUAL RESET ALARM RELEASE BOX (For 100~240VAC or 24VAC or 24VDC) INSTRUCTION MANUAL WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual
More information2408/2900. Fire Guard
2408/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2408 Single-Point Hold Open Applications and Mounting Details... 2 2408 Track Assemblies, Arms and Components...
More informationLayout S. 6 DORMA CI-2012 Englisch Stand
TS 3 V Door Closer TS 3 V Door Closer Easy to fit, economical and with adjustable closing force Simple, easy installation, and guaranteed quality. Tested to EN 54 Specially designed for internal doors,
More informationDC300 Rack and pinion door closer with link arm
Rack and pinion door closer with link arm ASSA ABLOY Rack and pinion closer with link arm L190 Certified in compliance with EN 114, size 3-6 Suitable for fire and smoke protection doors For single action
More informationEHT/EHTD. Electromechanical Closer-Holder Release Devices
351 EHT/EHTD Electromechanical Closer-Holder Release Devices Copyright 2003-2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Table of Contents Page
More information7200 Series. Electromechanical Closer/Holder Releasing Devices
7200 Series Electromechanical Closer/Holder Releasing Devices INTRODUCTION The 7200 Series Electromechanical Closer/Holders combine the functions of an electromechanical door holder with the 7700 series
More information2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved
Fire Guard SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard Table of Contents Features and Additional Fire Opening Devices............................1 2408 Single-Point Hold Open
More informationDC200 Rack and pinion door closer with link arm
114 Door closers Rack and pinion door closer with link arm ASSA ABLOY Certified in compliance with EN 114, size 2-4 Suitable for fire and smoke protection doors For single action doors up to 10 mm wide
More informationWARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION
WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing and/or servicing this product. As with all releasing device
More informationDS160/161 Request To Exit PIR sensors Installation Instructions
DS160/161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for request to exit (REX) interior applications. It is UL Listed
More information2409/2900. Fire Guard
2409/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2409 Single-Point Hold Open Applications and Mounting Details... 2 2409 Track Assemblies, Arms and Components...
More informationAn ASSA ABLOY Group brand Series. Electromechanical Closer-Holder Releasing Device
An ASSA ABLOY Group brand 4200 Series Electromechanical Closer-Holder Releasing Device introduction The 4200 Series Electromechanical Closer-Holders combine the functions of an electromechanical door holder
More informationRELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:
RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release
More informationSingle Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors
Hinge Edge of Door Hinge Edge of Door Wiring Instructions for the Sargent 0 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL
More informationInstallation Instructions
Installation Instructions Self-Cleaning Radiant Electric Drop-In Range JDP47, JD968, JD900 If you have questions, call 1.800.GE.CARES or visit our website at: ge.com Before You Begin Read these instructions
More information120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.
00000 (0) 00 PowerMatic Low Energy Power Operator Wiring Instructions 0 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE. REQUIREMENTS: U.L.
More informationTHE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL
S S S S S S OLID TATE ECURITIES, INC S S 90 SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED 99Y9 RESET U L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE
More information5900 SERIES Low Energy Power Operator
Low Energy Power Operator introduction The Norton 5900 Series is a full-featured, extremely quiet, low energy door operator designed for moderate to high traffic doors. This cost-effective operator is
More informationSOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL
S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE
More informationASSA ABLOY Series Power Operator Installation and Instruction Manual 6060 / Reveal. Adjusting Rod (08-13)
6000 Series Operator Installation and Instruction Manual ASSA ABLOY 6060 / 6070 1 3 5 4 6 2 Item No. Description 1 2 Motor (6000M) Cover (6000COV) 3 4 Control Inverter (6000IN) Supply 24VDC (6000SUP) Reveal
More informationFirefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL
Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling
More informationAn ASSA ABLOY Group brand Series. Architectural Door Closers
An ASSA ABLOY Group brand 2700 Series Architectural Door Closers introduction Yale 2700 series architectural door closers are ideal for commercial applications where ease of use, installation and aesthetics
More informationWiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door
CAUTION Hinge Edge of Door Wiring Instructions Checkmate Series with Single Point Hold-Open Combination Door Closer-Holder and Releasing Device with or without Integral Smoke Detector INSTALLER: LEAVE
More informationINSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)
INSTRUCTION MANUAL AlarmGard Chain Operator (Model FCA) & AlarmGard Crank Operator (Model FKA) WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within
More informationInstallation Instructions
Installation Instructions Electric Drop-In Range JDS28, JDP39 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN Read these instructions carefully and completely.
More informationMADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL
RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: These Time Delay Release Devices are U.L. Listed, Canadian Listed,
More informationDS160/DS161 Request To Exit PIR sensors Installation Instructions
DS160/DS161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160 is a Passive Infrared Detector (PIR) which is UL Listed as an Access Control Device under the UL 294 Standard.
More informationDC340 Rack and pinion door closer with guide rail or link arm
128 Door closers Rack and pinion door closer with guide rail or link arm ASSA ABLOY Available with heigth-adjustable guide rail G195 or standard guide rail G193 Certified in compliance with EN1154, size
More information5900 Series X-in Low Energy Power Operator
5900 Series X-in Low Energy Power Operator INTRODUCTION The Norton 5900 Series X-in is a full-featured, extremely quiet, low energy door operator designed for moderate to high traffic doors. This cost-effective
More informationDORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut
DORMA Free Swing and Hold-open Solutions for Fire Doors An alternative to Fire door keep shut Permanently closed fire doors can present an obstacle to building occupants, particularly on circulation routes,
More informationInstallation Instructions
4 3 Installation Instructions Self Cleaning Free-Standing Electric Range EER2000, EER3000, EER3001, EER3002, JBP10, JBP24, JBP26, JBP30, JBP35, JBP48, JBP64, JBP66, JBP68, JBP69, JBP71, JBP78, JBP80, JBP82,
More informationSPECIFICATIONS. Contents List
INSTALLATION INSTRUCTIONS FOR PB-SA PUSH BUTTON SYSTEM ABORT The information contained in this installation instruction is a quick reference guide. For detailed system information refer to the panel manufacturers
More information3480/RCH SERIES INSTALLATION INSTRUCTIONS
3480/RCH SERIES INSTALLATION INSTRUCTIONS NOTE: If plaster frame is required for installation order it as an option. ATTENTION: Read carefully before attempting to install or operate the heater. GENERAL
More informationModular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N: " Narrow Stile Plastic Template. Mortise.
103182 June 3, 2010 Delayed Egress Parts Check List V40 EM Centercase/Pushpad Modular SubAssembly P/N: 104374-X Plastic Template Use for ease of installation P/N: 103806-X Detex Corporation, 302 Detex
More informationWiring Instructions (01-09)
CAUTION Wiring Instructions 0--00-0 (0-0) Power Track Series with Single Point Hold-Open Electromechanical Releasing Device with Multi-Point Hold- Open TO PREVENT ELECTRICAL SHOCK AND EQUIPMENT DAMAGE,
More informationHighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75
General Information: is intended for linear lighting in storerooms, walk-in coolers, indoor and outdoor soffits, outdoor canopies, car washes, and a variety of other lighting applications. Do not mount
More informationInstallation. Built-in Full Height Wine Cellar VCWB301
Installation Built-in Full Height Wine Cellar VCWB301 Table of Contents Warnings & Important Information _ 3 Dimensions _ 5 Specifications _ 6 Cutout Dimensions 7 Cabinet Information _ 8 Cabinet Information
More informationSK-Duct Air Duct Smoke Detector
INSTALLATION AND MAINTENANCE INSTRUCTIONS I56-3432-001R 12 Clintonville Road Northford, CT 06472 203.484.7161; Fax: 203.484.7118 SK-Duct Air Duct Smoke Detector http://www.silentknight.com Specifications
More informationCEILING FAN OWNER'S MANUAL
Distinctive Lighting and Ceiling Fans CEILING FAN OWNER'S MANUAL MODEL: 52CW2L5-GM 52CW2L5-OBB READ AND SAVE THESE INSTRUCTIONS FOR CEILING FAN PARTS AND SERVICE, CALL 1-877-902-5588 FAN RATING AC 120V.
More informationINSTALLATION AND MAINTENANCE
INSTALLATION AND MAINTENANCE DH100ACDCIA & DH100ACDCPA Air Duct Smoke Detector Before Installing ULC standard CAN/ULC-S524-M91 Standard For The Installation Of Fire Alarm Systems should be referenced for
More informationD2E Duct Smoke Detector
INSTALLATION AND MAINTENANCE INSTRUCTIONS D2E Duct Smoke Detector Specifications Operating Temperature: 20 to 60 C Storage Temperature: 20 to 60 C Humidity: 0% to 93% Relative Humidity Non-condensing Air
More informationAddendum for STI-6406 with Dual Access Control
Addendum for STI-6406 with Dual Access Control Description: This system contains a STI-6400 with a DPDT key switch to be mounted on one side of a door or wall; and a similar looking housing, also with
More informationT874 Multistage Thermostat and Q674 Subbase
SUPER TRADELINE T874 Multistage Thermostat and Q674 Subbase Application The T874D Thermostat and Q674E Subbase provide 4 to 30 Vac control of standard stage heating and stage cooling systems. The Y594D
More informationACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F
II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy
More informationINSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011
INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES 10-343 ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011 INSTRUCTION MANUAL FireGard Chain Operator (Model FCF) & FireGard
More informationInstallation Instructions for W2H Series Signals
Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling
More informationD285DH. Installation Instructions Photoelectric Duct Smoke Detector
D85DH EN Installation Instructions Photoelectric Duct Smoke Detector D85DH Installation Instructions.0 Introduction FCC Notice The D85DH Photoelectric Duct Smoke Detector complies with Part 5 of the Federal
More informationViking Installation Guide
Viking Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit the Viking Web site at vikingrange.com
More informationMODEL B2 INSTALLATION MANUAL
RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and
More informationInstallation Guide. 15 W./24 W. Undercounter Refrigeration
Installation Guide 15 W./24 W. Undercounter Refrigeration Table of Contents Warnings & Important Information 3 Proper Disposal 4 Dimensions (15 W. Professional) 5 Dimensions (24 W. Professional) 6 Dimensions
More informationAUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL
AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL AR C Rev.06 WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to
More informationInstallation Instructions
Dear customer! Thank you for choosing this quality product from ASKO. We hope it will meet your expectations and fulfil your needs for many years to come. Scandinavian design combines clean lines, everyday
More informationIntegrated Refrigeration
INSTALLATION GUIDE Integrated Refrigeration Contents Integrated Refrigeration....................... 3 Model Specifications.......................... 4 Site Preparation.............................. 6
More informationEcoVision Door Manual
EcoVision Door Manual for Reach-In (RMTD) Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O ECOVISION REACH-IN DOORS
More informationFIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL
FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release
More informationDISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE
DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE COVE DISHWASHER Contents 3 Cove Dishwasher 4 Specifications 7 Door Panel 9 Installation 15 Troubleshooting Features and specifications
More informationExit Stopper. STI-6400 Series
Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, duration and immediate or 15 second delay for arming and trip. May be
More informationViking Installation Guide
Viking Installation Guide IMPORTANT Please Read and Follow! Please read all instructions thoroughly before installing the Convection Microwave Hood. Two people are recommended to install this product.
More informationInstallation Instructions
Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 1540/1541 7084 433-00 Important Please read and follow these instructions These instructions contain Danger, Warning and Caution
More informationRELEASE DEVICE CONTROLS
RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a
More informationCM-RQE70A PIR REQUEST TO EXIT DETECTOR
Door Activation Devices CM-RQE70A PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (2) MOV's BP7175 1. GENERAL DESCRIPTION Camden CM-RQE70A Request-to-Exit Sensor
More informationCM-RQE70 PIR REQUEST TO EXIT DETECTOR
Door Activation Devices CM-RQE70 PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (1) Wiring Harness (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (6) Wire Nuts (2) 's BP7175 1. GENERAL DESCRIPTION Camden
More informationTS 93. Cam action door closer system in Contur Design
TS 9 Cam action door closer system in Contur Design VERSATILE AND ELEGANT The TS 9 cam action door closer system provides a high-quality architectural solution for all project application requirements.
More informationSection 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.
CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions 1 PACKAGE CONTENTS Wiring Harness 6 Wire Nuts #6 x 3/4 Screws s BP7175 3/16 Wall Plugs Section 1: General Description Camden CM-RQE-70 Request-to-Exit
More informationInstallation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA
Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-845-4641 U L C U L 15 W./24 W. Undercounter Refrigeration
More informationModel PF 2030 Wide Area Vacuum Cleaner
Model PF 2030 Wide Area Vacuum Cleaner OPERATING INSTRUCTIONS COMMERCIAL WIDE AREA SWEEPER VACUUM CONGRATULATIONS YOU HAVE JUST ACQUIRED A HIGH QUALITY VACUUM CLEANER. PLEASE READ THIS MANUAL CAREFULLY,
More informationInstallation & Service Manual
Installation & Service Manual NFJGCX, NCJGCX, NTJGCX, NFMJGCX, NFJGECX, NCJGECX GLASS FRONT JUMBO ISLAND FROZEN FOOD/ICE CREAM/ MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.
More informationCam action door closer system DORMA TS 93
Cam action door closer system DORMA TS 93 reddot design award winner 200 DORMA TS 93 Cam action door closer system DORMA TS 93 Cam action door closer system TS 93 G-SR-EMR Versatile and elegant The TS
More informationExit Stopper. STI-6400 Series
Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, alarm duration and delay settings. May be mounted on top, right, left
More informationDETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS
TEST LOG Detector Identification Information Manufacturer and Serial Date Detector Model: Number: Installed: Description of Detector Location: Test Results and Maintenance Data Date Test Test Maintenance
More informationCEILING FAN OWNER'S MANUAL
CEILING FAN OWNER'S MANUAL MODEL: Pelham HVFC# 2299 Old Bronze Satin Nickel Polished Nickel READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz. CUL LISTED MODEL: AC-554SY05-7S WEIGHT OF THE FAN:
More informationTraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM
TTC-1 TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION The nvent RAYCHEM TraceTek TTC-1 sensing module is used with TraceTek sensing cables to detect liquid leaks.
More informationInstallation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits
Manufacturer of Medical Gas Pipeline Equipment Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits Master Alarm Conversion Combination Alarm
More informationInstallation Instructions
Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HCB 1560/1561 7084 429-00 Important Please read and follow these instructions These instructions contain Danger, Warning
More informationMulti-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.
M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp
More informationMODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS
Specifications subject to change without notice. USA 150303 Page 1 of 10 MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice.
More informationUndercounter Refrigeration
INSTALLATION GUIDE Undercounter Refrigeration Contents Undercounter Refrigeration..................... 3 Undercounter Specifications.................... 4 Site Preparation..............................
More informationKIT IOM
8733 800-259 KIT IOM Replacement Kit: 641-176 641-187 641-225 641-244 1 Table of Contents THE UPM CONTROLLER...3 SPECIFICATIONS...4 KIT INCLUDES...5 INSTALLATION PROCEDURE...5 Remove Old Board...5 Mounting
More informationThe feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.
Satellite Antenna De-icing Systems Automatic De-icing System for Protection against Snow and Ice Simple to Field Install and Operate Engineered for Customer Specified Voltages Low Energy Costs User selectable
More information01_TT_TST_04_61_GB.qxd :30 Uhr Seite 4. Door Closers and Door Control Systems
0_TT_TST_04_6_GB.qxd 5.08.004 9:0 Uhr Seite 4 Door Closers and Door Control Systems 4 0_TT_TST_04_6_GB.qxd 5.08.004 9:0 Uhr Seite 5 4 6 Concealed cam action door closers with slide channel Cam action and
More informationTRUERH Series HE-67xx Humidity Element with Temperature Sensor
Installation Instructions HE-67xx Issue Date 0501 TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation IMPORTANT: The HE-67xx Series Humidity Element with Temperature Sensor is designed
More informationD343. Installation Instructions. Air Duct Smoke Housing
D E Installation Instructions Air Duct Smoke Housing D Installation Instructions.0 Overview. Trademarks ational Fire Alarm Code is a trademark of the ational Fire Protection Association, Inc. ife Safety
More informationTHE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL
S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE
More informationMicrowave/PIR Intrusion Detector with POPIT Interface ZX970
Microwave/PIR Intrusion Detector with POPIT Interface ZX970 Installation Instructions 1.0 Specifications Input Power: 9 to 15 VDC, 6 ma nominal (35 ma with LED on) Zonex Current Draw: 500 ma Standby Power:
More informationRPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev
RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed
More informationService Manual Trash Compactor Models 15XESSEXF A November 2010 Broan-NuTone LLC 926 West State Street Hartford, WI
Service Manual Trash Compactor Models 15XESSEXF 99044663A November 2010 Broan-NuTone LLC 926 West State Street Hartford, WI 53027 1-800-637-1453 2 Safe Servicing Practices Safe Servicing Practices To avoid
More informationT8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase
M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B
More informationCEILING SPEAKER SYSTEM
Rev. A INSTRUCTION MANUAL CEILING SPEAKER SYSTEM F-122CU2 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for
More informationInstallation and Use Manual
Installation and Use Manual EMABFWS-RF and LMABFWS-RF Retrofit Bottle Filling Stations IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED
More informationInstaller Guide. WARNING Important Safety Information. 1 Specifications
1 Specifications cont. Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Conventional and Heat Pump Thermostat Installer Guide Before Installing, Programming or Operating, PLEASE READ ALL
More informationL62GB BASO Safety Shutoff Device
Installation Instructions Issue Date August 18, 2008 L62GB BASO Safety Shutoff Device Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These instructions are
More informationTYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER
Installation Instructions Model AD-HR Air Duct Monitoring Housing INTRODUCTION The SIEMENS Model AD-HR is a sampling tube, air duct monitoring housing. When used with a compatible smoke detector, smoke
More information