1 Bid Specifications Fire Alarm Equipment and Parts USA Bid No Equivalent Mfr. Part No. Manufacturer Equivalent Item Description Kidde Kidde Smoke Detector Kidde Kidde Smoke Detector w battery 50 BG-12LX Addressable Manual Pull Station, Dual-Action, Lexan, Key Lock 40 MCBL-7 DACT phone cords 7 Feet 40 Addressable Manual Pull Station, with BG-12L Features and BG-12LX Addressable Interface mounted inside the pull station. 40 2W-B Smoke Detector, Photo, 2-Wire, 12/24VDC, Plug-in Base 40 Smoke Detector, Photo Thermal, 2-Wire, 12/24VDC, Plug-in Base 2WTA-B w/ Built in sounder 40 2WT-B Smoke Detector, Photo Thermal, 2-Wire, 12/24VDC, Plug-in Base 40 4WT-B Smoke Detector, Photo Thermal, 4-Wire, 12/24VDC, Plug-in Base 40 RFP Red Retrofit Plate (5 pack) 25 2W-B i³ Photo Detector, 2-wire, 12/24 Vdc, Photo. 20 2W-MOD2 i³ 2-Wire Loop Test/Maintenance Module. 20 2WT-B i³ Photo Detector, 2-wire, 12/24 Vdc, Photo Thermal. 20 4W-B i³ Photo Detector, 4-wire, 12/24 Vdc, Photo. 20 4WT-B i³ Photo Detector, 4-wire, 12/24 Vdc, Photo Thermal P 135 F (57 C) fixed and rate-of-rise. (Plain) F (90 C) fixed and rate-of-rise F (57 C) fixed temperature F (90 C) fixed temperature F (57 C) fixed and rate-of-rise, dual circuit F (90 C) fixed and rate-of-rise, dual circuit F (57 C) fixed temperature, dual circuit F (90 C) fixed temperature, dual circuit F (57 C) electronic fixed & ROR heat; requires B400 series base. 20 P2R Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75, 30, 75,110,115 cd 20 P2R-P Horn/Strobe, 12/24V, Red, Multi-Candela 15,15/75, 30, 75,110,115 cd, Plain (No Lettering) 20 P2W Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, 30,75,110,115 cd 20 P2W-P Horn/Strobe, 12/24V, White, Multi-Candela 15,15/75, 30, 75,110,115 cd, Plain (No Lettering) 20 P2RK Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30, 75,110,115 cd, Outdoor, Includes backbox 20 PC2WK White outdoor horn strobe, ceiling mount 20 MHR Mini Horn, Red 20 MHW Mini Horn, White 20 Page 1 of 8

2 SPSCR Ceiling, Red, Selectable Candela, Speaker/Strobe 20 RFPW White Retrofit Plate (5 pack) 20 BB-STD Standard 4 square box. 20 WBB Weatherproof Backbox, Red. 20 MDF-300 Same as MMF-300, w/one additional Style B/D (Class A/B) Initiating Device Circuit 20 MMF-300 Addressable Monitor Module, One Style B/D (Class A/B) Initiating Device Circuit for Monitoring N/O Contact Devices, includes Polling LED 20 MMF-301 Device Circuit for Monitoring N/O Contact Devices, Does Not Include a Polling LED 20 MMF-302 Device Circuit for Monitoring Compatible 2-Wire Smoke Detectors, includes Polling LED. Refer to the Fire-Lite Alarms Device 20 I300 Isolator Module -- Required for Style 7 (Class A) SLC 20 BG-12LA Dual action, Lexan, Red, terminals, Key lock, Auxiliary Contacts 20 Contacts, Listed for outdoors using a WBB, or SB-I/O outdoor BG-12LAO Backbox. 20 BG-12LAOB Same as BG-12LAO, includes a SB-I/O outdoor Backbox 20 BG-12LO Dual action, Lexan, Red, terminal block, Key lock, w/gasket, Listed for Outdoor Use 20 BG-12LOB Dual action Lexan station, Red, terminal block, Key lock, with Gasket and SB-I/O Outdoor Backbox, Listed for Outdoor Use 20 BG-8 Manual Pull Station, Single-Action, Aluminum, SPST 20 2WTR-B Smoke Detector, Photo Thermal, 2-Wire, 12/24VDC,Plug-in Base, w/form-c Relay 20 4WTA-B Smoke Detector, Photo Thermal, 4-Wire, 12/24VDC, Plug-in Base w/ Built in sounder 20 4WTR-B Smoke Detector, Photo Thermal, 4-Wire, 12/24VDC, Plug-in Base, w/form-c Relay 20 4WTAR-B Smoke Detector, Photo Thermal, 4-Wire, 12/24VDC, Plug-in Base w/ Built in sounder and Form-C Relay 20 APA451 Remote Annunciator with Piezo Sounder, Alarm & Power LED s 20 RA400Z Remote LED -- Mounts to Single-Gang Box 20 RTS451 Remote Test Station with Switch, Alarm & Power LED s 20 RTS451KEY Remote Test Station with Switch,Alarm & Power LED's, Key Reset 20 D2 InnovairFlex 2-wire conventional photoelectric duct detector, includes 2151 detector. 10 D4120 InnovairFlex 4-wire conventional photoelectric duct detector, includes 2D51 detector. 10 D4120W InnovairFlex 4-wire conventional photoelectric duct detector, includes 2D51 detector, watertight. 10 D4S InnovairFlex 4-wire conventional sensor only component 10 2D51 Replacement 4-wire head 10 EOLR-1 12 or 24 volt EOL relay module. 10 APA151 Annunciator with piezo, alarm and power LED s. 10 RTS151KEY Remote test station; with switch, alarm and power LED s, key reset. 10 A77-AB2 i³ Retrofit Adapter Bracket. 10 STI9713 S.T.I. Steel Web Stopper for Photoelectric Smoke detector 10 STI1280 S.T.I. Back Plate for Stopper II Series 10 Page 2 of 8

3 STI1210D S.T.I. Horn Strobe Cover, surface mount. 10 STI1221D S.T.I. Strobe Cover, surface mount. 10 CHR Chime only; 12/24 volt; Red 10 CHW Chime only; 12/24 volt; White 10 CHSR Chime/Strobe; 15,15/75,30,75,110 Multi-Candela, 24 volt; Red 10 CHSW Chime/Strobe; 15,15/75,30,75,110 Multi-Candela, 24 volt; White 10 P2RK-P Red outdoor horn strobe, plain 10 P2RH Horn/Strobe, 12/24 Volt, Red, High-candela, 135,150,177,185 cd 10 P2WH Horn/Strobe, 12/24 Volt, White, High-candela, 135,150,177,185 cd 10 P2WH-P Horn/Strobe, 12/24 Volt, White, High-candela, 135,150,177,185 cd, Plain (No Lettering) 10 P2RHK Horn/Strobe, 12/24 Volt, Hi Candela, 135,150,177,185 cd, Red Outdoor, Includes backbox 10 P4R Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75, P4W Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, P4RK Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Outdoor, Includes backbox 10 P4WK White outdoor horn strobe, 4 wire 10 P4RK-R Replacement Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Outdoor 10 PC2R Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75, PC2R-P Horn/Strobe, 12/24V, Red, Multi-Candela 15,15/75, 30,75,110,115 cd, Plain (No Lettering) 10 PC2W Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, PC2W-P Horn/Strobe, 12/24V, White, Multi-Candela 15,15/75, 30,75,110,115 cd, Plain (No Lettering) 10 PC2W-SP Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75,30,75,110,115 cd, Fuego 10 PC2RK Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Outdoor, Includes backbox 10 PC4R Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75, PC4W Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, PC4WK White outdoor horn strobe, ceiling mount, 4 wire 10 PC4RH Horn/Strobe, 12/24 Volt, Red, High-candela, 135,150,177,185 cd 10 SPRK Wall, Outdoor, Red, Speaker only 10 SPWK Wall, Outdoor, White, Speaker only 10 SPSRK Wall, Outdoor, Red, Selectable Candela, Speaker/Strobe 10 SPSRK-PG Wall, Outdoor, Red, Selectable Candela, Speaker/Strobe, Portugese 10 SPSWK Wall, Outdoor, White, Selectable Candela, Speaker/Strobe 10 Wall, Outdoor, White, Selectable Candela, Speaker/Strobe, SPSWK-PG Portugese 10 SPSCW-P Ceiling, White, Selectable Candela, Speaker/Strobe, Plain 10 SPSCWK Ceiling, Outdoor, White, Selectable Candela, Speaker/Strobe 10 Ceiling, Outdoor, White, Selectable Candela, Speaker/Strobe, SPSCWK-PG Portugese 10 Page 3 of 8

4 SPSCWK-SP Ceiling, Outdoor, White, Selectable Candela, Speaker/Strobe, Spanish 10 SPBBSC Ceiling, Back Box Skirt, Red 10 SPBBSCW Ceiling, Back Box Skirt, White 10 SA-WBB Weatherproof Back Box - Wall Mount, Red 10 R-10T Relay, SPDT, Multivolt, Track mount 10 R-10E Relay, SPDT, Multivolt, Track mount, metal enclosure 10 R-14T 4-Gang Relay, SPDT, Multivolt, Track mount 10 R-14E 4-Gang Relay, SPDT, Multivolt, Track mount, metal enclosure 10 R-20T Relay, DPDT, Multivolt, Track mount 10 R-20E Relay, DPDT, Multivolt, Track mount, metal enclosure 10 R-24T 4-Gang Relay, DPDT, Multivolt, Track mount 10 R-24E 4-Gang Relay, DPDT, Multivolt, Track mount, metal enclosure 10 PR-1 Relay, SPDT, Multivolt, 24VDC, 24/115VAC 10 PR-2 Relay, SPDT, Multivolt, 10-40VDC 10 PR-3 Relay, SPDT, Multivolt, 10-40VDC, Redundant power input 10 HRB1224 DPDT Relay 12/24VDC 5A 120 VAC 10 HRB610 SPDT Rly 6Pk 120AC/12/24VDC10A Channel, dual line slave DACT. Requires PRO-411 programmer Channel dual line slave programmer DACT, Form-C Relay and 411UD Up/Download Capability. Requires PRO MS-10UD-7 10 Zone Conventional Fire Control Panel with 7 amp power supply. 10 MS-5UD-3 5 Zone Conventional Fire Control Panel with 3 amp power supply. 10 MS-5UD-7 5 Zone Conventional Fire Control Panel with 7 amp power supply. 10 CP355 Addressable Low-Profile Ionization Smoke Detector; includes B350LP base 10 SD355 Addressable Low-Profile Photoelectric Smoke Detector; includes B350LP base 10 SD355T Addressable Low-Profile Photoelectric Smoke Detector w/thermal Sensor; includes B350LP base 10 AD355 Photoelectric Smoke Detector and Thermal, Capable of Heat-Only alarm mode. Clip Mode Only; includes B350LP base 10 H355R Addressable Heat Detector w/rate-of-rise Thermal Sensor; includes B350LP base 10 H355HT Addressable High Heat Detector; includes B350LP base 10 BEAM355 Addressable Beam Detector 10 BEAM355S Addressable Beam Detector 10 Addressable Photoelectric Low-Flow Duct Detector, Includes Smoke D350PL Head 10 D350RPL Same as D350PL, with Built-In Relay 10 IPDACT Internet Communicator. Requires compatible FL panel equipped with on-board or optional DACT. 10 IPBRKT Used for mounting IP communicators in common enclosure for MS- 5UD-3, MS-10UD-7, MS-9050UD, MS-9200UDLS 10 IPENC Enclosure used for mounting IP communicators next to Legacy FACP enclosures 10 Page 4 of 8

5 411UDAC Communicator. 1 Amp of NAC power, integral battery charger, upload/download capability. Programmable using PRO-411 or PK- 10 BG12TR Lexan Trim Ring for all BG12 series Pull Stations 10 SB-10 Surface Mount Backbox Spare Hex Wrench 1/ Spare Fire-Lite Key Set (2) 10 BG-2R Surface Mounting Backbox, Red, Tapped for 1/2" Conduit 10 SB-10 Surface Mount Backbox P 135 F (57 C) fixed and rate-of-rise, normally open F (90 C) fixed and rate-of-rise, normally open F (57 C) fixed temperature, normally open F (90 C) fixed temperature, normally open F (57 C) fixed and rate-of-rise, dual circuit, normally open F (90 C) fixed and rate-of-rise, dual circuit, normally open F (57 C) fixed temperature, dual circuit, normally open F (90 C) fixed temperature, dual circuit, normally open 10 APC-1 Protective Cover for A and AT Heat Detectors F (57 C) vertical mount F (90 C) vertical mount AW F (57 C) vertical mount, for indoor or outdoor use AW F (90 C) vertical mount, for indoor or outdoor use 10 4W-B Smoke Detector, Photo 4-Wire, 12/24VDC, Plug-in Base 10 DH100LP Low-Flow Duct Smoke Detector, Photo, 2-Wire, 12/24 VDC 10 A5180 Replacement DH100 Photoelectric detector board, 2-Wire 10 A5190 Replacement DH100 Photoelectric detector board, 4-Wire 10 A Replacement DH100LP 2-wire power board 10 A Replacement DH100ACDCI/P 4-wire power board 10 ST-1.5 Metal Sampling Tube for 1' to 2' Duct Widths 10 ST-3 Metal Sampling Tube for 2' to 4' Duct Widths 10 ST-5 Metal Sampling Tube for 4' to 8' Duct Widths 10 ST-10 Metal Sampling Tube for 8' to 10' Duct Widths 10 RA100Z Remote LED. Mounts to single gang box. 5 RTS151 Remote test station; with switch, alarm and power LED s. 5 STI9601 S.T.I. Low profile smoke detector cover. 5 STI9602 S.T.I. Steel WEB Stopper, low profile, surface mount. 5 STI9604 S.T.I. Heat detector steel cover. 5 Page 5 of 8

6 STI9605 S.T.I. Steel WEB Stopper, medium profile, surface mount. 5 STI9609 S.T.I. Smoke detector cover, high profile. 5 STI9610 S.T.I. Steel WEB Stopper, high profile, surface mount. 5 STI1229 S.T.I. NEMA 4X rated Stopper Dome 5 Manual Pull Station Cover, Mini-Stopper without Horn, Flush STI6500 S.T.I. Mount 5 STI1130 S.T.I. Stopper II with horn, surface. 5 STI1230 S.T.I. Stopper II, no horn, surface. 5 STI3150 S.T.I. Weather Stopper II, surface mount. 5 STI3002 S.T.I. Weather gasket. 5 STI3003 S.T.I. Conduit gasket. 5 STI3100 S.T.I. Conduit spacer, surface mount. 5 SW-ALERT Amber Strobe, white housing, Multi-candela, ALERT 5 SWH-ALERT Amber Strobe, white housing, Hi-candela, ALERT 5 SPSW-ALERT Speaker Strobe, Standard cd, White, Amber Lens 5 White ceiling mount speaker strobe with clear lens and ALERT SPSCW-CLR-ALERT marking 5 SW-CLR-ALERT Strobe, Standard cd, White, Clear Lens 5 SCW-CLR-ALERT White ceiling mount strobe with clear lens and ALERT marking 5 HR Horn Only, 12 or 24 volt, Red, Wall Mount 5 HW Horn Only, 12 or 24 volt, White, Wall Mount 5 Horn Only, 12 or 24 volt, Red, Wall Mount, Outdoor, Includes HRK backbox 5 HRK-R Replacement Horn, Red, Wall Mount, Outdoor 5 P2WK White outdoor horn strobe 5 P2WK-P White outdoor horn strobe, plain 5 Replacement Horn/Strobe, 12/24 Volt, Red, Multi-Candela P2RK-R 15,15/75,30,75,110,115 cd, Outdoor 5 P4RH Horn/Strobe, 12/24 Volt, Red, High-candela, 135,150,177,185 cd 5 PC4WHK White outdoor horn stobe, ceiling mount, high candela, 4 wire 5 SR Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd 5 SR-P Strobe, 12/24V, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Plain (No Lettering) 5 SR-SP Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Fuego 5 SW Strobe, 12/24 Volt, White, Multi-Candela 15,15/75,30,75,110,115 cd 5 SW-P Strobe, 12/24V, White, Multi-Candela 15,15/75,30,75,110,115 cd, Plain (No Lettering) 5 SRK Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Outdoor, Includes backbox 5 SPR Wall, Red, Speaker only 5 SPW Wall, White, Speaker only 5 SPSRK-P Red outdoor speaker strobe, plain 5 Page 6 of 8

7 SSM V, 10 Bell. 5 SSM V, 6 Bell. 5 SSM V, 8 Bell. 5 HPT /24VDC Multi-function Timer 5 ANN Char LCD serial annunciator, Red 5 ANN-80-W 80 Char LCD serial annunciator, White 5 MS-9050UD 50 Pt Addressable panel, supports 50 modules or detectors in any combination 5 MS-9200UDLS Addressable Fire Alarm Control,198-Points on One Signaling Line Circuit (SLC) Loop, 24VDC 5 MS-9200UDLSE Addressable Fire Alarm Control,198-Points on One Signaling Line Circuit (SLC) Loop, 24VDC, Export, 220 volt Three-gang electrical box for mounting LCD-80F 5 MS-9600 Addressable Fire Alarm Control, 636-Points on Two Signaling Line Circuit s (SLC s), (2nd SLC optional), 24VDC 5 CMF-300 Addressable Control Module -- One Supervised, Style Y/Z (Class A/B) Notification Appliance (Bell) Circuit. 5 CRF-300 Addressable Relay Module -Built-In Two Form-C Relays 5 DACT-UD Upload / Download Digital Alarm Communicator Transmitter for the MS UDACT-F Universal D.A.C.T. Mounts in S2000, or MS-9200 Cabinet or ABS- 8RF or UBS-1F. Note use DACT-UD with MS-9600 Rev. 2 5 BG-12LR Dual action, Lexan, Red, terminal block, Key lock, for Agent Release Applications 5 BG-12LRA and LED Annunciation, for Agent Release Applications, Use with SBA-10 Surface Mount Backbox Spare HEX Wrench -- 1/8" Spare Fire-Lite Key 5 CO1224 Conventional Carbon Monoxide Detector, 12/24 VDC, with sounder and trouble relay; UL2075 listed 5 BEAM1224 Projected Beam Smoke Detector, Single-ended Reflected Type, Includes Trouble Relay, Transmitter/Receiver in One Unit. 4 DST1 InnovairFlex sampling tube, steel, 1 with holes 4 DST1.5 InnovairFlex sampling tube, steel, 1.5 with holes 4 DST3 InnovairFlex sampling tube, steel, 3 with holes 4 DST5 InnovairFlex sampling tube, steel, 5 with holes 4 DST10 InnovairFlex sampling tube, steel, 10 with holes 4 ETX InnovairFlex exhaust tube, steel, 1 4 TR Wall, Trim Ring, Red (5 pack) 4 TRW Wall, Trim Ring, White (5 pack) 4 TRC Ceiling, Trim Ring, Red (5 pack) 4 TRCW Ceiling, Trim Ring, White (5 pack) 4 BEAM1224S Same as BEAM1224 with Built-in Sensitivity Test Filter. 2 where there is difficulty in maintaining the set angle. When installed 6500-MMK with the transmitter/receiver unit, 6500-SMK must be used as well) 2 Grand Total Page 7 of 8

8 Discount off your advertised list price for all other fire alarm equipment and accessories % Page 8 of 8

The Advance You ve Been Looking For

The Advance You ve Been Looking For The Advance You ve Been Looking For The Power Behind The Products System Sensor was founded in 1984 and today is the largest manufacturer of fire detection and notification appliances in the world. More

More information

Fire Safety Products. Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Fire Safety Products. Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring F U L L - L I N E P R O D U C T G U I D E Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring At System Sensor, innovation is more

More information

Fire Safety Product Catalog

Fire Safety Product Catalog Fire Safety Product Catalog Innovation is our way of life. At System Sensor, innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing

More information

Fire & Life Safety Products CATALOG

Fire & Life Safety Products CATALOG Fire & Life Safety Products CATALOG Audible/Visible Notification Beam Smoke Detection Carbon Monoxide Detection HVAC Duct Smoke Detection and Monitoring Smoke Detection Fire Sprinkler Systems Monitoring

More information

Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS CONVENTIONAL PANEL W/ BUILT-IN DIGITAL ALARM COMMUNICATOR

Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS CONVENTIONAL PANEL W/ BUILT-IN DIGITAL ALARM COMMUNICATOR Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS 2-ZONE FIRE ALARM CONTROLS MS-2 Fire Alarm Control Panel, 2-Zone, Class B, 24VDC, One Class B $455.00 NAC MS-2E Export version of MS-2; 220 Volts $455.00

More information

Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring F U L L - L I N E P R O D U C T G U I D E Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring At System Sensor, innovation is more

More information

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E SpectrAlert Advance Description System Sensor SpectrAlert Advance offers a variety of devices designed for mass notification, including plain devices for non-fire applications, amber lens strobes and speaker

More information

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop MS-9600 Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop DF-52395:A A1-90 Addressable General The Fire Lite MS-9600 is a compact, cost-effective, intelligent addressable fire alarm control

More information

Reshaping Duct Smoke Detection

Reshaping Duct Smoke Detection Reshaping Duct Smoke Detection When System Sensor introduced the Innovair line of duct smoke detectors and accessories, it was revolutionary. Mechanical contractors and fire systems installers like you

More information

Lite-Configurator Version 3.1 Readme

Lite-Configurator Version 3.1 Readme Lite-Configurator Version 3.1 Readme 2007-2018 by Honeywell International, Inc. All Rights Reserved In this Release This Readme document contains release notes for Lite-Configurator Version 3.0. It includes

More information

Vista-50P/-50PUL System Design Sheet

Vista-50P/-50PUL System Design Sheet Vista-50P/-50PUL System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-50P (Nine Hardwired Zones, One Addressable Loop, Wireless)

More information

Reshaping Duct Smoke Detection

Reshaping Duct Smoke Detection Reshaping Duct Smoke Detection Y TE + TEST COIL TEST COIL + IN + OUT RA + RA + RTS (+) 24 VDC AUX POWER SUPPLIED BY USER (100mA SUPPLY) 24 VAC (+10%, 15%) FULL WAVE RECTIFIED, UNFILTERED POWER MAY BE USED

More information

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series Intelligent Analog/ Fire Alarm/Voice Integration Systems IntelliKnight TM Series CONVENTIONAL FIRE ALARM CONTROL PANELS SK-Conventional Series 2- to 30-Zone Fire Alarm Control Panels (FACPs) Whether your

More information

Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices. White Paper February 2014

Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices. White Paper February 2014 Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices White Paper February 2014 Designed to be watertight and to operate in a wide temperature range, SpectrAlert Advance

More information

Innovation that Endures

Innovation that Endures Innovation that Endures Fire-Lite on our NEW Emergency Communication Alarms is the first non-proprietary brand to receive UL2572 listing System! www.firelite.com Suppression Control Panels Fire-Lite s

More information

Vista-128FB System Design Sheet

Vista-128FB System Design Sheet Vista-128FB System Design Sheet FIRE DETECTION SPRINKLER SUPERVISION INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-128FB (Eight Hardwired Zones,

More information

Vista-20SEUL System Design Sheet

Vista-20SEUL System Design Sheet System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic -Features QED programming for quick enrollment of devices (Eight Hardwired Zones, Wireless) Part

More information

Agent Release Control Panel

Agent Release Control Panel Agent Release Control Panel System Capacity Annunciators: 8 Electrical Specifications RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps RP-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps

More information

Control / Communicator

Control / Communicator ARMED READY A D S SPACE B E T R C F X ENTER MAX INSTANT READY R BYPASS FA2000C Control / Communicator BS/ESC N/Y SHIFT 1 4 5 6 7 8 9 0 2 # 3 ARMED READY FA560 A 1 OFF 2 AWAY 3 STAY B 4 5 TEST 6 C 7 8 CODE

More information

NBG-12LR and NBG-12LRA

NBG-12LR and NBG-12LRA NBG-12LR and NBG-12LRA Dual-Action Agent Release Stations DN-6840:B F-710 Releasing Panels General The NBG-12LR and NBG-12LRA are Agent Release Stations designed for use with NOTIFIER Fire Alarm Control

More information

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1002ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

SECTION FIRE ALARM SYSTEMS

SECTION FIRE ALARM SYSTEMS SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

Full Line Catalog and Product Brochures

Full Line Catalog and Product Brochures Welcome to E DOCS Electronic Documents on CD-ROM This disc contains Product s Product Installation s Agency Listings Applications Guides Full Line Catalog and Product Brochures click below to search by

More information

!+ NCA-2-TC Network Control Annunciator-2, 640-characters-Traditional Chinese Network Control Annunciator-2, Traditional Chinese $1,587.

!+ NCA-2-TC Network Control Annunciator-2, 640-characters-Traditional Chinese Network Control Annunciator-2, Traditional Chinese $1,587. Notifier-Honeywell Description Short Description List Intelligent Control Panels & Addressable Initiating Devices ONYX NFS2-3030 Fire Alarm Control Panel CPU2-3030D NFS2-3030 CPU with 640-character Display;

More information

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Fire Safety Products ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Cerberus PRO 252-point

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed for Control Units for Fire Protective Signaling Systems (UL

More information

Intelligent Control Panel SLC. Wiring Manual. Document Rev: P9 7/26/2018 ECN:18-323

Intelligent Control Panel SLC. Wiring Manual. Document Rev: P9 7/26/2018 ECN:18-323 Intelligent Control Panel SLC Wiring Manual Document 51309 Rev: P9 7/26/2018 ECN:18-323 Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates, it

More information

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN:

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN: MODEL 5496 Intelligent Power Module Installation and Operations Manual Document 151276 08/12/10 Rev: E1 P/N 151276:E1 ECN: 10-484 Contents Section 1 Overview... 1-1 1.1 5496 Description... 1-1 1.2 Agency

More information

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev Altronix Corp. 140 58th St. Brooklyn, NY AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 052313 Agency Listings: UL Listed for Control Units for

More information

Vista-10SE System Design Sheet

Vista-10SE System Design Sheet Vista-10SE System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic Vista-10SE -Features QED programming for quick enrollment of devices Part No. Qty. Each

More information

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize advanced ideas advancedsolutions At System Sensor, Research and Development is more than a department. It s a way of life. Every day we work to design new products that utilize the most innovative technologies

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM Waterflow Alarm Submittal Booklet For MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM 380 South 5th St Monroe, OR 2G CONSTRUCTION PO Box 11735 Eugene, OR Convergint Technologies LLC 16575 SW 72nd Avenue

More information

Intelligent Control Panel SLC. Wiring Manual. Document /17/2014 Rev: P4 P/N 51309:P4 ECN

Intelligent Control Panel SLC. Wiring Manual. Document /17/2014 Rev: P4 P/N 51309:P4 ECN Intelligent Control Panel SLC Wiring Manual Document 51309 9/17/2014 Rev: P4 P/N 51309:P4 ECN 14-790 Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance

More information

AL600ULX Series. Power Supply/Charger. Installation Guide

AL600ULX Series. Power Supply/Charger. Installation Guide AL600ULX Series Power Supply/Charger Installation Guide Models Include: AL600ULX - Single Output AL600ULPD4 AL600ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL600ULPD8 AL600ULPD8CB - Eight

More information

Invitation to Bid - Bid # 3095

Invitation to Bid - Bid # 3095 Rutherford County Schools Invitation to Bid - Bid # 3095 Product/Service: Fire Alarm and Intercom Parts The Rutherford County Board of Education requests you to bid on this project subject to the terms

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs AL300ULX Series Power Supply/Charger Installation Guide Models Include: AL300ULX - Single Output AL300ULPD4 AL300ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL300ULPD8 AL300ULPD8CB - Eight

More information

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability.

More information

Fire Alarm Control Systems Simple. Smart. Reliable.

Fire Alarm Control Systems Simple. Smart. Reliable. Fire Alarm Control Systems Simple. Smart. Reliable. PROVEN PERFORMANCE Honeywell Silent Knight Fire Alarm Systems Founded in 1961, Honeywell Silent Knight designs and manufactures commercial fire alarm

More information

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L MODEL 5495 Distributed Power Module Part Number 151161 Rev L Installation and Operations Manual Contents Section 1 Introduction...1 Section 2 UL Requirements...2 2.1 ULC Requirements...2 Section 3 System

More information

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL March 30, 2000 Section: Audio/Visual Devices G-250 SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL System Sensor SpectrAlert Series strobes, horns, and combination horn/strobes are UL listed

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE s Desigo Fire Safety Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Desigo 252-point and 504-point addressable

More information

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs AL400ULX Series Power Supply/Charger Installation Guide Models Include: AL400ULX - Single Output AL400ULPD4 AL400ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL400ULPD8 AL400ULPD8CB - Eight

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

4007ES Fire Control Panels

4007ES Fire Control Panels UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* 4007ES Fire Control Panels 4007ES Hybrid, Fire Detection and Control Panel with Addressable and/or Conventional Initiation Features Satisfies a variety

More information

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description CONVENTIONAL FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron's MMX-2003-12NDS is a powerful intelligent networkable fire alarm solution designed

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone

More information

MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC

MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC PN: 52646:B ECN 08-188 Fire Alarm Control Panel MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC IMPORTANT! The SLC Wiring Manual Document #51309 must be referenced in addition to this manual when

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2003-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

TrueAlert Multi-Candela Notification Appliances

TrueAlert Multi-Candela Notification Appliances UL, ULC Approved* TrueAlert Multi-Candela Notification Appliances Non-Addressable Visible Only Amber Lens Strobes for Emergency Communications Features Visible only (V/O) 24 VDC wall mount notification

More information

ECC-50/100(E) Emergency Command Center

ECC-50/100(E) Emergency Command Center ECC-50/100(E) Emergency Command Center DF-60734:A9 C-200 General Fire Lite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

SECTION : FIRE ALARM & DETECTION SYSTEMS

SECTION : FIRE ALARM & DETECTION SYSTEMS SECTION 28 31 10: FIRE ALARM & DETECTION SYSTEMS 1. GENERAL A. This section applies to fire detection/alarm system and carbon monoxide system components and equipment installed during new construction

More information

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number: 109-B Concord Drive Casselberry, FL 32707 407.830.6500 DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72 Pg 1 of 4 Equity One 11180600 Owner/Representative: WO#: _Customer#: 1550 NE Miami Garden Dr

More information

Manual Call Point-Installation efficiency, Flexibility and full compliance with latest standards are at the heart of new Indoor Call Point range.

Manual Call Point-Installation efficiency, Flexibility and full compliance with latest standards are at the heart of new Indoor Call Point range. At System Sensor, innovation is more than an ideal; innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing our customers with

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

LifeAlarm Fire Alarm Control Panels

LifeAlarm Fire Alarm Control Panels LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient

More information

Siemens: Cerberus Division

Siemens: Cerberus Division Ionization Detectors and Bases DI-3 Ionization Detector 309.00 DI-B3 Ionization Detector (for use with Duct Housing) 357.00 DB-3S Series 3 Low Profile Base (for DI-3) 22.00 Photoelectric Detectors and

More information

FA-1000 SERIES. Microprocessor-Based Fire Alarm Control Panel. Installation and Operation Manual

FA-1000 SERIES. Microprocessor-Based Fire Alarm Control Panel. Installation and Operation Manual FA-1000 SERIES Microprocessor-Based Fire Alarm Control Panel Installation and Operation Manual LT-600 Rev. 19 May 2017 Table of Contents 1.0 Introduction 8 1.1 About this Manual... 8 1.2 About the FA-1000...

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

4007ES Fire Control Panels

4007ES Fire Control Panels UL, ULC, CSFM Listed; FM Approved* Features Flexible standard combination of addressable initiation and addressable notification 4.3 (109 mm) Diagonal color touchscreen display: Convenient and intuitive

More information

MS-9200UD/MS-9200UDE

MS-9200UD/MS-9200UDE PN: 51906:A ECN 02-398 Fire Alarm Control Panel MS-9200UD/MS-9200UDE IMPORTANT! The SLC Manual Document #51309 must be referenced in addition to this manual when installing or servicing the Fire Alarm

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

AL602ULADA. NAC Power Extender. Installation Guide (see 02 Application Guide for additional information) More than just power. TM. Rev.

AL602ULADA. NAC Power Extender. Installation Guide (see 02 Application Guide for additional information) More than just power. TM. Rev. Altronix Corp. 140 58th St. Brooklyn, NY AL602ULADA NAC Power Extender Installation Guide (see 02 Application Guide for additional information) Rev. 042209 More than just power. TM Overview: Altronix AL602ULADA

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

BPS NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

BPS NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev BPS-1002 NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 101413 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864). MEA

More information

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K PEGAsys Multi-Loop Intelligent Suppression Control System A UTC Fire & Security Company Effective: March 2007 K-76-028 FEATURES UL Listed CSFM Approved MEA Approved Peer-to-Peer Networking (to 32 nodes)

More information

Analog fire panels FPA-1000 Family

Analog fire panels FPA-1000 Family Analog fire panels FPA-1000 Family en NAC Compatibility List Analog fire panels NAC compatibility en 3 1 NAC compatibility 1.1 General notes Bosch Security Systems found the following notification appliance

More information

Addressable Fire Alarm Control Panel MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC Manual

Addressable Fire Alarm Control Panel MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC Manual Addressable Fire Alarm Control Panel MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC Manual Document 52646 2/12/2010 Rev: B2 P/N 52646:B2 ECN 10-098 Fire Alarm System Limitations While a fire

More information

12 Clintonville Road, Northford, CT Technical Manual MS-9200 DOCUMENT # /28/97 REV: B P/N 50428:B1 ECN

12 Clintonville Road, Northford, CT Technical Manual MS-9200 DOCUMENT # /28/97 REV: B P/N 50428:B1 ECN 12 Clintonville Road, Northford, CT 06472 Technical Manual MS-9200 Addressable Fire Control Panel (Export Version) DOCUMENT # 50428 7/28/97 REV: B P/N 50428:B1 ECN 97-316 Installation Precautions - Adherence

More information

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY FIRE ALARM INSPECTION AND TESTING SUMMARY PAGE PER 2013 NFPA 72 Inspector: Jim Smith Test Date: 5/22/2014 PROPERTY INFORMATION Name of Property: Windsor Tower Owner of Property: Jim Gibbs Properties Address:

More information

Fire alarm system specification for multiple tenant retail buildings

Fire alarm system specification for multiple tenant retail buildings Date: June 20, 2011 Project name: Baederwood Shopping Center Multiple Tenant Buildings B & C City/ State: Abington, PA Landlord s Vendor Contact: Dan Morrin Jr., NECCO Security Phone: (215)638-7999 Email:

More information

Section 4: Operating Instructions

Section 4: Operating Instructions Section 4: Operating Instructions 4.1 Panel Control Buttons 4.1.1 Acknowledge/Step The first press of the Acknowledge/Step key silences the piezo sounder, changes flashing LEDs to steady and also changes

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Multiple Input and Output Modules

Multiple Input and Output Modules Kingfisher Company, inc. Multiple Input and Output Modules Features: Removable 12 to 18 AWG plug-in terminal blocks Individual LED indicators Unused addresses may be disabled Rotary address switches Class

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

Silent Knight Device Compatibility

Silent Knight Device Compatibility Silent Knight Device Compatibility SK-5208 Conventional FACP SK-2 / SK-4 Conventional FACPs 5495 6A Conventional Distributed Power Supply 5496 6A Intelligent Distributed Power Supply 5499 9A Conventional

More information

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL The FireNET 427 control panel is an analog addressable fire alarm panel containing 2 or 4 SLC loops with each loop supporting 27 devices of

More information

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE The Door Switch 11772 Westline Industrial Drive St. Louis, Mo 63146 (877) 998-5625 www.thedoorswitch.com Patent No. RE42,991 and RE44,039 CONTROL PANEL TRANSFORMER (SUPPLIED WITH CONTROL PANEL) NOTIFICATION

More information

PART IV DETAILED SPECIFICATION

PART IV DETAILED SPECIFICATION PART IV DETAILED SPECIFICATION PART IV DETAILED SPECIFICATIONS SECTION ONE: GENERAL 1.1 Scope A. This specification document provides the requirements for the installation, programming and configuration

More information

STATE OF NORTH CAROLINA

STATE OF NORTH CAROLINA STATE OF NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CONSTRUCTION OFFICE Fire Alarm GUIDELINES AND POLICIES 2011 Instruction to Designers: 1. Designers for State projects involving fire alarm systems

More information

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax Date 9-10-2016 Project: Field Elementary School Pasadena, CA FIRE ALARM SUBMITAL Devices Used DESCRIPTION MODEL MANUFACTURE CSFM SMOKE DETECTOR FSP-851 NOTIFIER 7272-0559;0129 HEAT DETECTOR FST-851H NOTIFIER

More information

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev Altronix Corp. 140 58th St. Brooklyn, NY AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 101413 AL1042ULADA NAC Power Extender Overview: The Altronix

More information

/5121/5122 TrueAlert Power Supply Installation Instructions

/5121/5122 TrueAlert Power Supply Installation Instructions 4100-5120/5121/5122 TrueAlert Power Supply Installation Instructions Introduction This publication provides an overview of the features, specifications, and capabilities of the TrueAlert power supplies

More information

by Honeywell MS-9050UD(E) FireuTeALarms Fire Alarm Control Panel with DACT NOTIFICATION APPLIANCE CIRCUITS (NACS)

by Honeywell MS-9050UD(E) FireuTeALarms Fire Alarm Control Panel with DACT NOTIFICATION APPLIANCE CIRCUITS (NACS) MS-9050UD(E) Fire Alarm Control Panel with DACT DF-52418:E1 A1-20 FireuTeALarms by Honeywell Addressable General The Fire«Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter

More information