Advanced Power Monitor (APM)

Size: px
Start display at page:

Download "Advanced Power Monitor (APM)"

Transcription

1 Advanced Power Monitor (APM)

2 What is the APM? The Advanced Power Monitor (APM) is used to monitor and measure the RF coverage performance determining characteristics of a communications site, on an individual per-channel basis, and provides network owners, operators, or end-user customers with unparalleled levels of performance monitoring and fault reporting for their communications networks. Measurements and alarm events can be logged for viewing, or downloaded for historical analysis. Monitoring the Tx Forward Power and VSWR on the antenna side of the transmitter combiner ensures that any RF faults that would otherwise be masked by the combiner s isolators, and therefore not seen by the network base stations, can be monitored, measured, and have alarm conditions notified.

3 What does it look like? Advanced Power Monitor Front View Advanced Power Monitor Rear View

4 What can it do? The Advanced Power Monitor (APM) non-intrusively measures the RF performance of a communications site on a truly per-channel 24x7 basis, allowing coverage performance impacting problems to be detected promptly. The APM provides valuable detailed information on the fault condition, allowing appropriately prioritised maintenance activities to be decided - and efficiently and cost-effectively actioned - depending on the nature, severity, and impact of the fault.

5 What can it do? The APM may be used to monitor; Each channel s RF Forward Power output from the Tx combiner(s), The Tx antenna system s Reflected Power (VSWR) on each channel s operating frequency, The Tx Combiner s Insertion Loss on each channel s operating frequency, The received signal level (RSSI) for each channel s Rx frequency, and/or, Tx signal levels from surrounding sites to confirm network RF propagation An inbuilt signal generator in the APM can perform a system Tx-Rx Isolation test to confirm antenna isolation and Rx sub-system operation. When used with an optional Site Alarm Module (SAM), temperature, analogue voltages, and digital inputs may also be monitored by the APM to enhance its monitoring to include non-rf equipment at a network site.

6 Installation Tx ANTENNA 1 OPTIONAL DEDICATED Rx MONITORING ANTENNA CAM/SAM 1 TO ADDITIONAL COUPLERS IF REQUIRED APM + 1 ANTENNA LINE COUPLER COUPLER TOP VIEW - MOUNTED ON 1RU FRONT PANEL RFL APM REAR VIEW APM FRONT VIEW OPTIONAL CAM (s) & SAM (s) to CAM/SAM 10 FWD CAM/SAM REAR VIEW Tx COMBINER (1) FROM SPARE PORT ON BTS Rx MUX MONITORED CHANNELS BTS PTT LINE CONDITIONING 4 EXT ALARM INPUTS 10 CHANNEL ASSIGNED AND DEDICATED ALARM RELAY OUTPUTS 10 EXT ALARM INPUTS The APM conveniently connects into the site s Transmitter and Receiver multicoupling using a low-loss PIM and PIP rated Antenna Line Coupler fitted in each Tx antenna feeder line, and by using a spare port on the site s receiver multicoupler(s). Several Tx combiners at a site can monitored by one APM. Once installed, the APM continuously monitors the RF performance parameters of each channel non-intrusively on a 24x7 basis.

7 Configuration The APM features an integral webserver with a user-friendly Graphical User Interface (GUI) that allows the RF measurements made on each channel, and any alarm conditions, to be viewed. Per-channel configuration, alarm threshold levels, and other parameters can also be easily configured. SNMP alarm traps, and SMTP ( ) alarms can also be provided for prompt notification of performance impacting changes to normal measurement values.

8 Connectivity To access and use the webserver GUI, an internet browser such as Internet Explorer, Mozilla, or Firefox is used. Connection to the APM may be; locally via a computer using an Ethernet cable locally via a wireless router connected to the APM (i.e. WiFi) remotely via a customer s intra-site Local Area Network (LAN) remotely via a site linking backbone (such as microwave links, fiber, or other link technologies) remotely via a cellular router (if the APM site is within coverage of a cellular network) remotely via an IP protocol satellite link (ideal for very remote sites)

9 Configuration The APM s webserver GUI allows each channel s parameters to be configured independently. Other APM system parameters are also user-configurable.

10 Monitoring The APM s RF measurements for each frequency, and any associated alarm conditions, are presented in the GUI. Alarms are also available as relay outputs, SNMP Alarm Traps, and SMTP ( ) messages. Example SMTP ( ) Alarm Message Example SNMP Alarm Trap Message

11 If optional SAM modules are connected to the APM, their measurements and alarm conditions are also presented in the APM GUI. Monitoring

12 Summary The Advanced Power Monitor (APM) provides comprehensive channelised monitoring of the RF performance characteristics of a communications site. Monitoring is on a non-intrusive 24x7 basis and provides confirmation of the site s RF performance. Alarm notifications can also be provided to facilitate appropriately prioritised and cost-effective maintenance responses to faults.

13 More Information Advanced Power Monitor (APM) APM Product Brief and User Manuals APM Application Note, Service Bulletins, SNMP MIB files and downloads Site Alarm Module (SAM) SAM Product Brief and downloads

SERVICE BULLETIN ASM-SNMP

SERVICE BULLETIN ASM-SNMP ASM-SNMP SERVICE BULLETIN ASM-SNMP Product: Antenna System Monitor Subject: SNMP Date: 14 th September 2017 This Service Bulletin overviews the SNMP V2c northbound Trap and southbound GET request functionality

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

Universal Monitoring System. TrapServer Description

Universal Monitoring System. TrapServer Description TrapServer Description TrapServer is a centralized or distributed monitoring system used to monitor, assess and control a multi-vendor telecommunications networks. It consists of a server (rack or desk

More information

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

ICT180S-12I INTELLIGENT MODEL (SERIES 2) The Power of Reliability ICT180S-12I INTELLIGENT MODEL (SERIES 2) INSTRUCTION MANUAL TABLE OF CONTENTS Warnings Page 2 Product Description Page 3 Installation Page 4 LCD/Select Button Operation Page 7

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1 RF SCOUT PLUS INSTRUCTION MANUAL Dielectric, LLC 22 Tower Rd. Raymond, ME 04071 Phone: 800.341.9678 www.dielectric.com 21 January 2015, Rev B 1 WARNING Powering RF sensors above +30dBm (1W) will cause

More information

MiNi Server environment MoNitoriNg SySteM

MiNi Server environment MoNitoriNg SySteM enviromux-mini with enviromux-t-3 temperature Sensor Features & Applications Monitors threats: temperature Humidity Water Leakage intrusion The ENVIROMUX Mini Server Environment Monitoring System monitors

More information

OJD ITB No Attachment E Duress Alarm Equipment Specifications

OJD ITB No Attachment E Duress Alarm Equipment Specifications Duress Alarm Equipment Specifications PART 1 GENERAL 1.1 SECTION INCLUDES A. Duress devices. B. Alarm control panel. C. Signaling devices. 1.2 REFERENCE STANDARDS A. NFPA 70 - National Electrical Code;

More information

MultiSite Manager. Setup Guide

MultiSite Manager. Setup Guide MultiSite Manager Setup Guide Contents 1. Introduction... 2 How MultiSite Manager works... 2 How MultiSite Manager is implemented... 2 2. MultiSite Manager requirements... 3 Operating System requirements...

More information

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008 TCD Telemetry Communications Device Installation Guide Interface for the Emizon managed network Issue 1: February 2008 This guide sets out a simple check list together with a step-by-step guide to the

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. Dual Bus Distribution Panel Series INSTRUCTION MANUAL 855-314-000 Models: ICT200DF-12IRC ICT200DB-12IRC WARNING Risk of serious personal injury or damage to equipment

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. Dual Bus Distribution Panel Series INSTRUCTION MANUAL 855-314-000 Models: ICT200DF-12IRC ICT200DB-12IRC WARNING Risk of serious personal injury or damage to equipment

More information

Digivance CXD/NXD Element Management System EMS. User Manual ADCP Part Number Rev A Issue 1

Digivance CXD/NXD Element Management System EMS. User Manual ADCP Part Number Rev A Issue 1 Digivance CXD/NXD Element Management System EMS User Manual ADCP-75-199 Part Number 1344755 Rev A Issue 1 Page ii About This Manual This manual tells how to install and use the Digivance CXD/NXD Element

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS) The Power of Reliability BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS) INSTRUCTION MANUAL TABLE OF CONTENTS

More information

The WAVE Plus Instant Notification System for Schools and Colleges

The WAVE Plus Instant Notification System for Schools and Colleges Instant Notification System for Schools and Colleges Duress alarm has been activated in the School of Engineering! Schools strive to provide a safe environment for students and teachers. In an emergency,

More information

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY. SMARTER PERIMETER DETECTION SYSTEMS MicroPoint II Fence Detection System MicroTrack II Buried Cable Detection System MicroWave 330 Digital Microwave Link PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM

More information

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION All in One - All in Touch Video - Alarm System UNICA is a revolutionary alarm system based on architecture all-in-one composed by a burglar alarm (wired and

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

Common Questions & Answers

Common Questions & Answers Common Questions & Answers Summary of Advantages Honeywell has proven manufacturing and design capability, distribution expertise and the field training/support necessary for a successful partnership with

More information

REMOTE MONITORING AND ALARM SYSTEM

REMOTE MONITORING AND ALARM SYSTEM FUNCTIONALITY A. The water and wastewater facilities remote monitoring, reporting and alarm notification system shall be comprised of a hosted, Web-based user-interface which communicates to remotely monitored

More information

idware Idware Remote Site Monitoring Solution

idware Idware Remote Site Monitoring Solution idware Idware Remote Site Monitoring Solution 2 TOPIC 1. Why a Remote Site Monitoring solution is mandatory for a TELCO? 2. Remote Site Monitoring features a) Power monitoring b) Security Monitoring c)

More information

Model 135 Reference Document

Model 135 Reference Document Model 135 Reference Document 2007 by Gordon Kapes, Inc. all rights reserved 5520 West Touhy Avenue Skokie, Illinois 60077 USA Telephone 847 676-1750 Fax 847 982-0747 www.gkinc.com 40218, Issue 1 January

More information

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation The thresholds for insulation and loop resistance are programmable via built-in buttons which are shown in the display of the main module. In addition to the settings the display can also indicate the

More information

PRO-WATCH NOTIFIER SECONDARY FIRE INTERFACE ARCHITECT AND ENGINEERING SPECIFICATION

PRO-WATCH NOTIFIER SECONDARY FIRE INTERFACE ARCHITECT AND ENGINEERING SPECIFICATION Section 00000 SECURITY PRO-WATCH NOTIFIER SECONDARY FIRE INTERFACE ARCHITECT AND ENGINEERING SPECIFICATION PART 1 GENERAL A. The intent of this document is to specify the minimum criteria for the design,

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

SENSAPHONE 901 Tryens Road Aston, PA PH:

SENSAPHONE 901 Tryens Road Aston, PA PH: SENSAPHONE 901 Tryens Road Aston, PA 19014 PH: 877-373-2700 www.sensaphone.com Why Choose Sensaphone Sensaphone products are designed to help you watch over a remote facility. Our range of Sensaphone solutions

More information

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway Code No. LIT-1201993 Software Release 2.1 Issued April 12, 2006 Supersedes July 20, 2005 Document Introduction.................................................

More information

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510 Dew point monitoring DS 400 for stationary dew point monitoring of refrigeration or desiccant driers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured

More information

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1% DC Voltage Sensor Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power

More information

CAN unit for Analog Sensors

CAN unit for Analog Sensors CAN unit for Analog Sensors Didactum`s Monitoring Systems have many uses: Monitoring of wring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power

More information

IndigoVision Alarm Panel. User Guide

IndigoVision Alarm Panel. User Guide IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE

More information

RAy SNMP. Application notes.

RAy SNMP. Application notes. Application notes. RAy SNMP. version 1.0 12/29/2017 RACOM s.r.o. Mirova1283 59231 Nove MestonaMorave CzechRepublic Tel.: +420565659 511 Fax: +420565659 512 E-mail: racom@racom.eu www.racom.eu Table of

More information

Didactum Monitoring System 100 III

Didactum Monitoring System 100 III Didactum Monitoring System 100 III The Monitoring System 100 III has many uses: Monitoring of wring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring

More information

SCR100 User Manual. Version:1.1 Date:Dec 2009

SCR100 User Manual. Version:1.1 Date:Dec 2009 SCR100 User Manual Version:1.1 Date:Dec 2009 Introduction: This document mainly introduces the installations and connections of SCR100 products, and the brief operations about attendance software. Important

More information

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04 RADview-EMS/TDM Element Management System for TDM Applications Optimux-1553 1994 2004 RAD Data Communications Publication 07/04 Contents Chapter 1. Introduction 1.1 Overview... 1-1 1.2 System Features...

More information

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide Grandstream Networks, Inc. Table of Contents INTRODUCTION... 4 GDS3710 WIRING CONNECTION... 5 Powering and Connecting the GDS3710... 5 Power and Data PINs... 5 Alarm In and Alarm Out PINs... 6 DETECT AND

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

Didactum Monitoring System 50

Didactum Monitoring System 50 Didactum Monitoring System 50 The Monitoring System 100 III has many uses: Monitoring of wring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of

More information

Why Choose Sensaphone? What Is A Sensaphone? If you have something important at a remote site, then you need a SENSAPHONE to watch it for you.

Why Choose Sensaphone? What Is A Sensaphone? If you have something important at a remote site, then you need a SENSAPHONE to watch it for you. What Is A? Humidity Smoke Frozen Pipes IT MONITORS A monitors a remote location and contacts you when problems are detected. You can check at any time to make sure everything is okay. IT NOTIFIES YOU products

More information

Room Alert. Room Alert 32E/W, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual

Room Alert. Room Alert 32E/W, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual Room Alert Temperature & Environment Monitoring... Made Easy! Room Alert 32E/W, 12E, 4E & 3E Phone 401.628.1600 Fax 401.628.1601 Web AVTECH.com User s Guide & Reference Manual AVT-151105-01 Contact Us

More information

Healthy. Atmosphere. for Pigs and Poultry. for a

Healthy. Atmosphere. for Pigs and Poultry. for a Healthy Atmosphere for Pigs and Poultry for a m e t s y s Your Climate ll requirements Alarm Energy Our new 3G product range for a healthy climate in stables for pigs and poultry! The 3G product range

More information

Dew point set DS 400

Dew point set DS 400 set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the

More information

Description of the. controllers. Description of the. system extension possibilities. RS communication. Front panel made of glass. Control of 2 valves

Description of the. controllers. Description of the. system extension possibilities. RS communication. Front panel made of glass. Control of 2 valves Description of the controllers Control of 2 valves Control of 3 valves Front panel made of glass Touchscreen Wireless communication Wired communication Update via USB Uploading photos via USB Control of

More information

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown] OPERATING MANUAL PCC Controller (PCC-01 and 1-149160G) [PCC-01 shown] www.unipowerco.com 2018 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com

More information

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution EnergyMaster ENEC Monitoring System An on-site supervision and remote monitoring solution ENERGYMASTER ENEC MONITORING SYSTEMS AN ON-SITE SUPERVISION AND REMOTE MONITORING SOLUTION Take Control of Your

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SYSTEM INTEGRATION AND TESTING. ITS:CLC 1 of 13 APPR:LWB:DBP: FHWA:APPR:

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SYSTEM INTEGRATION AND TESTING. ITS:CLC 1 of 13 APPR:LWB:DBP: FHWA:APPR: MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SYSTEM INTEGRATION AND TESTING ITS:CLC 1 of 13 APPR:LWB:DBP:08-01-13 FHWA:APPR:09-23-13 a. Description. This work consists of conducting system

More information

Measuring Recording Online Monitoring Regulation Alarming

Measuring Recording Online Monitoring Regulation Alarming Measuring Recording Online Monitoring Regulation Alarming Temperature Humidity CO 2 Dew point Atmospheric pressure Analog signals Two-state inputs Pulses Battery operated recorders and printers Economical

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

TELECOMMUNICATION. Telecommunication. Wireless Phone

TELECOMMUNICATION. Telecommunication. Wireless Phone TELECOMMUNICATION Telecommunication Wireless Phone Talkback System CCTV PAGA TV Distribution LAN / WAN System 25 Telecommunication Telecommunication projects in the Oil & Gas industry are often large,

More information

Home center Interface Server. Technical sheet

Home center Interface Server. Technical sheet Home center Interface Server Technical sheet September 2014 About Home center Interface Server is a product by Stijnen Solutions to operate your home automation system. Connect to this device with Home

More information

Advanced FireAlarm Panel 1-4Loop

Advanced FireAlarm Panel 1-4Loop Advanced FireAlarm Panel 1-4Loop Advanced Technologies Advanced Electronics Ltd IP Gateway Monitoring and interrogation via the internet Password protected multiple user permissions Event notification

More information

Batt-Safe Battery String Monitoring System

Batt-Safe Battery String Monitoring System Batt-Safe Battery String Monitoring System Technical White Paper October 2010 Introduction Battery monitoring systems are categorized as either cell monitors or string monitors. Battery cell monitors provide

More information

WAVE SEQUENCER DELIVERS:

WAVE SEQUENCER DELIVERS: The WAVE Sequencer employs state-of-the-art wireless technology to shut down and isolate vulnerable electrical components during local thunderstorms. The Sequencer receives digitally encoded signals from

More information

Installation, Configuration and User Manual

Installation, Configuration and User Manual Model 8826 System Controller Model 8826 System Controller Installation, Configuration and User Manual READ AND SAVE THESE INSTRUCTIONS WELCOME Thank you for choosing the Aprilaire HVAC Automation System.

More information

Fire Operator Workstation (Fire OWS) User s Guide

Fire Operator Workstation (Fire OWS) User s Guide Fire Operator Workstation (Fire OWS) User s Guide 1-1 Fire Operator Workstation (Fire OWS) User s Guide Introduction This user s guide details the components, capabilities, and operation procedures of

More information

secure signalling systems for I&HAS

secure signalling systems for I&HAS installation of IP-based secure signalling systems for I&HAS an industry guide May 2008 For other information please contact: British Security Industry Association t: 0845 389 3889 f: 0845 389 0761 e:

More information

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS Below you will find information about your installation and what you can expect to happen next. There are also some important steps to follow to ensure

More information

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks Multipurpose time server and grandmaster DTS 4148.grandmaster The DTS 4148.grandmaster sets new standards as a time reference for and PTP clients in medium and large networks (Ethernet/IPV4/IPV6). With

More information

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Combined CAN Sensor Unit Temperature, Humidity and Smoke Combined CAN Sensor Unit Temperature, Humidity and Smoke Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical

More information

Proliphix. Remote Management. User Guide

Proliphix. Remote Management. User Guide Proliphix Remote Management User Guide Rev 2.5 Page 2 of 12 Table of Contents Intended Audience...3 Remote Management...4 Remote Management Interface (RMI)...5 Accessing My Account... 5 Device List Page...

More information

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

PRODUCT CATALOGUE.   Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg PRODUCT CATALOGUE Cape Town 18 Darter Road Blue Water Estate Kommetjie Luke Fowles - 076 161 8124 luke@providenttech.co.za Frank Fowles - 082 445 1541 frank@providenttech.co.za www.providenttech.co.za

More information

Connectivity Control Confidence

Connectivity Control Confidence Connectivity Control Confidence Control Systems CS Designed and manufactured in the USA Letter from the CEO James Hawkins, CEO Kenall Manufacturing The lighting controls market has been dramatically transformed

More information

RACK MONITORING SYSTEM RAMOS Ultra

RACK MONITORING SYSTEM RAMOS Ultra version: 7-05-03 CONTEG DATASHEET COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 79/4 40 00 Prague 4 Tel.: +40 6 9 8 Fax: +40 6 9 9 Production

More information

FlexWave Element Management System. Alarm Reference FWPP May 2017

FlexWave Element Management System. Alarm Reference FWPP May 2017 FlexWave Element Management System Alarm Reference May 2017 DISCLAIMER This document has been developed by CommScope, and is intended for the use of its customers and customer support personnel. The information

More information

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure TRANSCOM INSTRUMENTS Product Brochure Transcom Instruments Product Brochure TY800 Leaky Feeder Monitoring Module Overview GSM-Railway communication system operational quality is closely related to daily

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

Outdoor Temperature Sensor

Outdoor Temperature Sensor Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET Instruction Manual Model 1582-125L 1:1 Switch February 2017, Rev. 0 CH1 HISTORY LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY LINE RESET MANUAL REMOTE AUTO PS1 PS2 MODEL 1582 CROSS TECHNOLOGIES INC.

More information

Getting started with

Getting started with Getting started with The Heating Hub Unit sits at the heart of your Polypipe system and makes your home cloud connected for both monitoring and control. IN THE BOX: Heating Hub Unit Plug top mains power

More information

Typical applications include the vibration detector. Detection of vibrations and shocks

Typical applications include the vibration detector. Detection of vibrations and shocks Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10 Company Overview Paragon Robotics wireless logging and monitoring solutions provide cost savings for powerful and scalable energy, life science, environmental and industrial systems. Add intelligent thermostats,

More information

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler CATALOGUE Controls/Networks 2018.1 -Coupler 1.3 Controls/Networks 2018.1 -Coupler -Coupler -Coupler Controls/Networks 2018.1 1.3 Extend (third-party) lift controls with LIFTnet, a dynamic fire control

More information

Clino Guard. Safety without Compromise

Clino Guard. Safety without Compromise Clino Guard Safety without Compromise Protection for disoriented persons Clino Guard, the disorientation care system from Ackermann, considerably simplifies the supervision of disoriented persons. If a

More information

Tri-Tech Medical Inc.

Tri-Tech Medical Inc. Submittal Data Sheet Project Information Project Number Approval Features The Master Alarm Panel conversion kits are designed to upgrade or retro-fit existing panels produced by several major brands. The

More information

Architectural and Engineering Specification for a Real-Time Locating System Flare

Architectural and Engineering Specification for a Real-Time Locating System Flare Architectural and Engineering Specification for a Flare AE-T1-IN-R3-E-0617 Page 1 of 14 This document is intended to provide performance specifications and operational requirements for the Flare. It is

More information

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing Control Panels Control Panels for Commercial Applications Control panels provide the central processing and logic for an integrated system. In a typical system, there are four major functions: inputs,

More information

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure. Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

Web-Based Control & Notification for Home Automation Alarm Systems

Web-Based Control & Notification for Home Automation Alarm Systems Web-Based Control & Notification for Home Automation Alarm Systems Helder Adão, Rui Antunes, and Frederico Grilo Abstract This paper describes the project and development of a very low-cost and small electronic

More information

VNCManager. Version June Developed by:

VNCManager. Version June Developed by: VNCManager Version 1.2 9 June 2014 Developed by: The WORKSPACESOLUTION, Inc. P.O. Box 490 Seaside, OR 97128 (503) 717-1821 ssherlock@workspacesolution.com www.workspacesolution.com 6/9/2014 Page i Table

More information

User-Manual MultiSensor-RACK. From Firmware Version 3.xx.xx.

User-Manual MultiSensor-RACK. From Firmware Version 3.xx.xx. User-Manual MultiSensor-RACK From Firmware Version 3.xx.xx www.kentix.de Content 1. Introduction an summary! 3 2. Features! 3 2.1. Applications! 3 2.2. Safety note and installation! 3 2.3. Environment!

More information

Room Alert. Room Alert 32E, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual

Room Alert. Room Alert 32E, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual Room Alert Temperature & Environment Monitoring... Made Easy! Room Alert 32E, 12E, 4E & 3E Phone 401.628.1600 Fax 401.628.1601 Web AVTECH.com User s Guide & Reference Manual AVT-171212-1.1.0 Contact Us

More information

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D ASCO 5350 The ASCO 5350 ATS Remote Annunciator is listed under the Underwriter s Laboratories Standard UL-1008 for Automatic Transfer Switch accessories. This stand-alone device provides individual status

More information

NorthStar. System Requirements. Quick Install Guide

NorthStar. System Requirements. Quick Install Guide NorthStar Quick Install Guide The instructions in this guide provide a basic overview for quickly getting results from a NorthStar lighting solution. They are intended to get you up and running quickly,

More information

Med Touch Master Alarm

Med Touch Master Alarm Submittal Data Sheet Features The Powerex Med Touch Master Alarm Panel monitors and displays normal and alarm conditions from up to 128 remote medical gas source signals and provides alarm conditions as

More information

IF-L/RF Protection Switch

IF-L/RF Protection Switch Instruction Manual Model 1582-1152 IF-L/RF Protection Switch August 2014, Rev. 0 CH1 HISTORY ALARM LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY ALARM LINE RESET MANUAL REMOTE AUTO ALARM PS1 PS2 MODEL

More information

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System SHIFT TEST BACK ENTER C910 SERIES STATUS OUTPUT ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM ACS-30 System MONITOR CONFIG POWER CONTROL MODULE ACCS-PCM-5 PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER

More information

HPE Modular Cooling System 200 User Guide

HPE Modular Cooling System 200 User Guide HPE Modular Cooling System 200 User Guide Abstract This document is for the person who installs racks and rack products. This procedure is performed only by trained personnel. Hewlett Packard Enterprise

More information

Galaxy Pulsar Plus Digital Battery Plant Controller

Galaxy Pulsar Plus Digital Battery Plant Controller Galaxy Pulsar Plus Digital Battery Plant Controller Features Supports up to 60 Power Modules rectifiers and converters Supports dual voltage plants, with rectifiers and converters Auto-sensing dual voltage

More information

D-TECT 3 IP. GJD260 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector D-TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 3 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller

Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller ProMtrac_Browser_Manual.docx (5/23/13) rev1: pn. 7501088 Please completely read through these operating instructions first! Do

More information

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Knürr RMS Compact II. Knürr RMS Compact II 2.81 Knürr RMS Compact II Knürr RMS Compact II 2.82 to 2.85 2.81 Knürr RMS Compact II Damage prevention with checks and controls System and network management requirements mean the systems ambient conditions

More information

NZQA unit standard version 2 Page 1 of 6. Perform installation and maintenance of telecommunications radio systems and services

NZQA unit standard version 2 Page 1 of 6. Perform installation and maintenance of telecommunications radio systems and services Page 1 of 6 Title Perform installation and maintenance of telecommunications radio systems and services Level 3 Credits 40 Purpose This unit standard covers basic skills for people engaged in installation

More information

Smart Wireless Sensor

Smart Wireless Sensor Smart Wireless Sensor G7 G7 creates the IoT platform of sensor data exchange and integration 64 wireless sensors each station * temperature, humidity, analog sensors, or digital alarm Windows / ios / Android

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

WebAlert WA500 Series Process Monitor Instruction Manual

WebAlert WA500 Series Process Monitor Instruction Manual W A L C H E M IWAKI America Inc. WebAlert WA500 Process Monitor WebAlert WA500 Series Process Monitor Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 FAX:

More information

description MpodX4 agent

description MpodX4 agent info@bitnia.com www.bitnia.com description MpodX4 agent Octopods Monitoring is an electronic system that provides monitoring and management of all kind of physical parameters: Relative humidity,, Electric

More information