Honeywell Durafit LED Retrofit Kit

Size: px
Start display at page:

Download "Honeywell Durafit LED Retrofit Kit"

Transcription

1 Honeywell Durafit LED Retrofit Kit INSTALLATION INSTRUCTIONS LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT < E354676>. APPLICATION The Honeywell Durafit LED Retrofit Kit is designed for use with an external Honeywell or Lutron EcoSystem driver ( VAC; 60Hz) and standard G13 Bi-pin lampholders wired to 32VDC output of an approved Honeywell or Lutron LED driver. Honeywell Durafit LED tubes are intended to retrofit 1, 2, 3 or 4 lamps, UL Listed surface mount, or type IC or non-ic recessed mount fluorescent luminaires with or without diffuser that use straight tubular lamps. These products are intended for use in dry or damp locations only. Please read all instructions before attempting installation. Use wire connectors and suitable tools when required. These instructions cover the following products: 2-Foot Lamps - Honeywell Energy Saver Driver 1-lamp kit 2-lamp kit 3000K HLEDRL1-2FT-1L-830-H30 HLEDRL1-2FT-2L-830-H K HLEDRL1-2FT-1L-835-H30 HLEDRL1-2FT-2L-835-H K HLEDRL1-2FT-1L-840-H30 HLEDRL1-2FT-2L-840-H K HLEDRL1-2FT-1L-850-H30 HLEDRL1-2FT-2L-850-H30 2-Foot Lamps - Lutron Ecosystem Driver 1-lamp kit 2-lamp kit 3-lamp kit 4-lamp kit 3000K HLEDRL1-2FT-1L-830-L3D HLEDRL1-2FT-2L-830-L3D HLEDRL1-2FT-3L-830-L3D HLEDRL1-2FT-4L-830-L3D 3500K HLEDRL1-2FT-1L-835-L3D HLEDRL1-2FT-2L-835-L3D HLEDRL1-2FT-3L-835-L3D HLEDRL1-2FT-4L-835-L3D 4000K HLEDRL1-2FT-1L-840-L3D HLEDRL1-2FT-2L-840-L3D HLEDRL1-2FT-3L-840-L3D HLEDRL1-2FT-4L-840-L3D 5000K HLEDRL1-2FT-1L-850-L3D HLEDRL1-2FT-2L-850-L3D HLEDRL1-2FT-3L-850-L3D HLEDRL1-2FT-4L-850-L3D 4-Foot Lamps, Honeywell Energy Saver Driver E lamp kit 2-lamp kit 3-lamp kit 4-lamp kit 3000K HLEDRL1-4FT-1L-830-H54 HLEDRL1-4FT-2L-830-H54 HLEDRL1-4FT-3L-830-H54 HLEDRL1-4FT-4L-830-H K HLEDRL1-4FT-1L-835-H54 HLEDRL1-4FT-2L-835-H54 HLEDRL1-4FT-3L-835-H54 HLEDRL1-4FT-4L-835-H K HLEDRL1-4FT-1L-840-H54 HLEDRL1-4FT-2L-840-H54 HLEDRL1-4FT-3L-840-H54 HLEDRL1-4FT-4L-840-H K HLEDRL1-4FT-1L-850-H54 HLEDRL1-4FT-2L-850-H54 HLEDRL1-4FT-3L-850-H54 HLEDRL1-4FT-4L-850-H

2 4-Foot Lamps, Honeywell High Output Driver 1-lamp kit 2-lamp kit 3-lamp kit 4-lamp kit 3000K HLEDRL1-4FT-1L-830-H72 HLEDRL1-4FT-2L-830-H72 HLEDRL1-4FT-3L-830-H72 HLEDRL1-4FT-4L-830-H K HLEDRL1-4FT-1L-835-H72 HLEDRL1-4FT-2L-835-H72 HLEDRL1-4FT-3L-835-H72 HLEDRL1-4FT-4L-835-H K HLEDRL1-4FT-1L-840-H72 HLEDRL1-4FT-2L-840-H72 HLEDRL1-4FT-3L-840-H72 HLEDRL1-4FT-4L-840-H K HLEDRL1-4FT-1L-850-H72 HLEDRL1-4FT-2L-850-H72 HLEDRL1-4FT-3L-850-H72 HLEDRL1-4FT-4L-850-H72 4-Foot Lamps, Honeywell Lutron Ecosystem Driver 1-lamp kit 2-lamp kit 3-lamp kit 4-lamp kit 3000K HLEDRL1-4FT-1L-830-L3D HLEDRL1-4FT-2L-830-L3D HLEDRL1-4FT-3L-830-L3D HLEDRL1-4FT-4L-830-L3D 3500K HLEDRL1-4FT-1L-835-L3D HLEDRL1-4FT-2L-835-L3D HLEDRL1-4FT-3L-835-L3D HLEDRL1-4FT-4L-835-L3D 4000K HLEDRL1-4FT-1L-840-L3D HLEDRL1-4FT-2L-840-L3D HLEDRL1-4FT-3L-840-L3D HLEDRL1-4FT-4L-840-L3D 5000K HLEDRL1-4FT-1L-850-L3D HLEDRL1-4FT-2L-850-L3D HLEDRL1-4FT-3L-850-L3D HLEDRL1-4FT-4L-850-L3D Ensure all parts and accessories are in the package: Installation Instructions Durafit LED replacement lamp(s) G13 medium bi-pin lampholders (2pcs per lamp) Field-applied UL LED relamping label Replacement LED driver(s) IMPORTANT SAFEGUARDS CAUTION Please read and follow these instructions before installation. Installation by qualified electricians only. Consult a competent electrician if you have any uncertainty about the installation or the use of the product. Do not use sharp tools near or on the surface of the tube. Hands must be dry during installation. Switch off the power at circuit breaker before installation. DO NOT SIMPLY SWITCH OFF THE FIXTURE. Make sure the base is mounted on a stable, even and secure surface. Beware of electric shock when replacing tube. Use or store the tubes in dry location. Replace the tube immediately if you find any leakage or damage on the tube. Stop use and replace if the product becomes dim, fails to illuminate or begins to blink. If failure occurs do not attempt to repair product. WARNING Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires and electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. CAUTION Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. CAUTION To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. IMPORTANT THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. To avoid electrical shock do not disassemble product. Product is intended to be used in recessed or surface mounted fixture, with or without diffuser. This product is not intended for use in emergency light fixtures or exit signs

3 This product is intended for dry location only. Not for use where exposed directly to the weather or water. NOTE: Shunted lampholders are found in fluorescent luminaires with Instant-Start ballasts. Instant-Start ballasts can be identified by the words Instant Start or I.S. marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. Risk of fire or electrical shock. Disconnect power before installation and verify that power is off before working on the fixture. Risk of fire or electrical shock. The electrical rating of this product is VAC. The installer must assure that there is VAC at the luminaire before installation. Do not connect to any other voltage other than VAC (nominal). Improper voltage matching, such as 347VAC, can result in performance degradation, physical damage and risk of serious injury. Intended to be used for surface-mounted or Type IC or Type non-ic recessed fluorescent UL Listed luminaires that use straight tubular maximum four 4-foot lamps or 2-foot lamps with diffuser. Do not install in a raceway or a luminaire marked for through branch wiring. For more information, Honeywell. BEFORE INSTALLATION Unpack the product Unpack and carefully examine the product from top to bottom. Ensure all parts and accessories are in the package. The retrofit installation requires the LED lamp, LED driver(s) and lampholders. Unpack and check all parts before installing. Some wiring is needed during installation. Save all packing materials and report any damage that may have occurred during shipping. Do not attempt to use this product if it is damaged. If you are retrofitting 1-lamp fixtures, you will need one LED lamp, one LED driver and one set of lampholders. M34935 Planning the installation Fig. 1. Example. This device installation requires planning to ensure successful installation with minimal complications and down time. User responsibilitie: It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate the device in such a manner as to comply with all state and local laws, ordinances, and regulations. HOW TO INSTALL NOTE: This user guide is intended to be used as a reference only. Installation should be done by a fully qualified electrician or technician. This document should never be considered as a substitute for any provision of a regulation or state and/or local code. Please read the entire user guide to fully understand and safely use this product. IMPORTANT IF you have any uncertainly about the installation, please consult a qualified electrician. 1. Make sure the circuit breaker that supplies power to the fixture is turned off. DO NOT SIMPLY SWITCH OFF THE FIXTURE. 2. Remove lens or diffusion cover of the lighting fixture (see Fig. 4; this step is also applicable to Fig. 2, Fig. 3 and Fig. 5)

4 LIGHTING FIXTURE (2FT X 2FT) M34936 Fig. 2. Light fixture (2ft x 2ft). LIGHTING FIXTURE (2FT X 4FT) M34937 Fig. 3. Light fixture (2ft x 4ft). BASE FLUORESCENT TUBE DIFFUSION COVER M34938 Fig. 4. Durafit LED Retrofit kit. LIGHTING FIXTURE (1FT X 2FT) LIGHTING FIXTURE (1FT X 4FT) M34939 Fig

5 90 M34940 Fig Rotate fluorescent lamps or pull down to remove, and safely recycle lamps according to local requirements. 4. Remove the ballast cover and identify the line and neutral wires running from the breaker box to the ballast and confirm the power is off using a voltmeter. 5. Cut the line and neutral wires at the ballast, as well as all remaining wires at the ballast. 6. Remove ballast (and starter if present). Dispose of removed ballast in accordance with government regulations in your area (see Fig. 7). 7. If not using existing lampholders, remove lampholders and lamp holder leads. 8. Install the LED driver. Driver(s) to be mounted within same wiring compartment as existing fluorescent ballast. See Fig. 8 for hole location dimensions. Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors or equivalent. See Fig. 9 and Fig. 12 for wiring instructions. M34941 Fig. 7. LUTRON A-SERIES STICK DRIVER 14-1/4 (362) 1/8 (3) LED DUAL DRIVER 10-7/8 (276) Fig Install any UL listed G13 lampholders. See Fig. 9 for more detail. 1/8 (3) M

6 G13 LAMPHOLDER STRUCTURE: 63/64 (25) 35/64 (14) 1-27/64 (36) (23) G13 LAMPHOLDER INSTALLED DISTANCE: Ø11/64 (4) 1 (25.5) /64 (9) /8 (3) 53/64 1-9/64 (29) (21) 25/64 (10.1) /64 (9) DC- 11/64 (4) T8- T12 INSTALLATION DETAIL: ,5-1 PUSH-THROUGH FIXING LAMP CENTRE HEIGTH (FROM THE BOTTOM OF THE METAL PLATE) PBT GREEN ROTOR WITH POSITION OF... RIGID CONDUCTOR SECTION 0, FIXING METAL PLATE THICKNESS VERSION WITHOUT STOP NIB PUSH-WIRE TERMINALS WITH ANYONE HOLES RIGID WIRES STRIPPING I=L+17 LAMPHOLDER DC- LAMPHOLDER DC+ DC+ OUTPUT DC- DC+ N INPUT G L M34943 Fig If dimming, connect plenum rated wire to 0-10V dimming terminals marked DC-/DC+; if not dimming, leave these terminals bare. 11. Reinstall the ballast cover to hide all wires. 12. Affix UL retrofit kit labels, visible to lamp installers (See Fig. 10 for relamping label). 13. Reinstall lens or diffusion cover. 14. Turn power on at the breaker box. 15. Test fixture operation. CAUTION Risk of fire or electric shock. Install the LED T9 retrofit LED tubes only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings shown on this installation sheet. Fig. 10. Relamping label

7 DURAFIT LED LIGHT TUBE INSTALLATION HONEYWELL DURAFIT LED RETROFIT KIT Before installation: 1-LAMP FIXTURE 3-LAMP FIXTURE 2-LAMP FIXTURE 4-LAMP FIXTURE M34944 Fig. 11. LED installation: 1-LAMP FIXTURE 3-LAMP FIXTURE 2-LAMP FIXTURE 4-LAMP FIXTURE M34945 Fig. 12. With Electronic Ballast: Remove fluorescent tube. Cut the wire as shown on the broken line of the diagram (Fig. 11). Bypass the ballast and remove the starter (if any) within the bracket. Reconnect wires as shown. Join DC+ with positive wire and DC- with negative wire. Install T9 LED lamp in the lampholders. AC120V-277V N G L LED SINGLE DRIVER AC120V-277V N G L LED DUAL DRIVER M34946 Fig

8 By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Automation and Control Solutions Honeywell International Inc Douglas Drive North Golden Valley, MN customer.honeywell.com U.S. Registered Trademark 2013 Honeywell International Inc M.S Printed in United States

1 General Description

1 General Description 1 General Description LED Tube Light adopts the new type LED as the light source, using the standard TB tube's end caps, makes it easy to install and replace the traditional fluorescent lamp. The TRF-51894

More information

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. LED Tube Lamp (Linear Fluorescent Replacement) Retrofit Installation Instructions The product package includes the following components: 1. Integral LED Lamp (1 unit) 2. Fixture Warning Label (1 - self-adhesive)

More information

CR Series Command Relays

CR Series Command Relays CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for

More information

Innovative Lighting R-Series Overhead LED Conversion Kits

Innovative Lighting R-Series Overhead LED Conversion Kits Installation Guide Innovative Lighting R-Series Overhead LED Conversion Kits For Commercial Walk-In Coolers and Freezers BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow

More information

Innovative Lighting R-Series Vertical Refrigeration

Innovative Lighting R-Series Vertical Refrigeration Installation Guide Innovative Lighting R-Series Vertical Refrigeration Door LED Conversionn Kits For Commercial Refrigerators and Freezers BEFORE YOU BEGIN INSTALLATION Read these instructions carefully.

More information

Installation Instructions

Installation Instructions Installation Instructions Ordering Code: RF16UQT1XXC RF32UQT1XXC RF32UHT1XX RF45UQT1XXC RF45UHT1XX PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION OF THE FOLLOWING: 4 STRIP FIXTURES 8 STRIP FIXTURES

More information

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits Installation Guide Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits For Commercial Refrigerated Multi-Deck Display Cases BEFORE YOU BEGIN INSTALLATION Read these instructions carefully.

More information

1 x4 Dimmable LED RetroFits

1 x4 Dimmable LED RetroFits 1 x4 Dimmable LED RetroFits Installation Instructions Ordering Code: RF16UQT1XXCDL RF16UHT1XXDL RF32UQT1XXCDL RF32UHT1XXDL PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION OF THE FOLLOWING: 4 STRIP FIXTURES

More information

Cold Door 2 LED Retrofit Kit Lighting System

Cold Door 2 LED Retrofit Kit Lighting System PAGE 1 OF 6 General Information Cold Door 2 is intended for use inside commercial refrigeration cases with packed foods only. Cold Door 2 LED luminaire should only be used with SloanLED 100 Watt 24 VDC

More information

Dioluce Products Installation Instructions

Dioluce Products Installation Instructions Dioluce Products Installation Instructions Models DL-R24-4530-5K0-001 DL-R24-4530-5K0-002 DL-R24-5035-5K0-001 DL-R24-5035-5K0-002 DL-R24-4530-4K0-001 DL-R24-4530-4K0-002 DL-R24-5035-4K0-001 DL-R24-5035-4K0-002

More information

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Cold Deck Canopy and Shelf Lights and Retrofit Kit PAGE 1 OF 8 General Information Cold Deck LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck

More information

LED Flat Panel Retrofit

LED Flat Panel Retrofit LED Flat Panel Retrofit Installation Instructions For 2 x2, and 2 x4 LED Flat Panel Retrofits (RP Series) PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION INTRODUCTION The LED Flat Panel Retrofit fits

More information

Installation Instructions

Installation Instructions Installation Instructions Ordering Code: RF32UQT1XX PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION OF THE FOLLOWING: 4 STRIP FIXTURES 8 STRIP FIXTURES HARDWIRE 4 STRIP FIXTURES WRAP FIXTURES TROFFER

More information

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE MODEL NUMBERS PHM4PC-xxxx-EM PHS4PC-xxxx-EM PRECAUTIONS Read and understand all instructions before beginning installation NOTICE: Follow National

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FHSKIT-T04LNX or FHSKIT-TXXXHX TABLE OF CONTENTS 1.0 INSTALLATION INSTRUCTION WARNINGS... PAGE 3 2.0 ORIGINAL FIXTURE PARTS... PAGE 4 3.0 HOTSPOT LED KIT PARTS... PAGE 5-6 4.0

More information

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended General Information Cold Deck FIT LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck FIT LED

More information

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 PRODUCT DATA FEATURES Solid or split core loop-powered current transmitters Fast response time Integral DIN rail mounting flange

More information

C7232A,B Sensor and Controller

C7232A,B Sensor and Controller C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR FEATURES PRODUCT DATA C7232A C7232B Used for CO 2 based ventilation control. Models available with LCD that provides sensor readings and status information.

More information

Dimmable LED Retrofit Kit

Dimmable LED Retrofit Kit ASD LED Recessed Retrofit Kit was designed as an energy-efficient lighting solution for remodeling or new construction projects. It is an ideal replacement for an incandescent lamp in the industry s most

More information

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT P.O. BOX 84 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 74-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Flow Lighting QuickLED NEW FIXTURE 2x4 2x2 1x4 Corporate 1240 Texan Trail, Suite 102 Grapevine, TX 76051 (817)435-8484 Office www.flowledlighting.com READ AND FOLLOW ALL SAFETY

More information

LED RETROFIT CONVERSION KITS

LED RETROFIT CONVERSION KITS Our LED RetroFit Conversion Kits come with a complete Gear Tray Assembly to convert older 4-foot and 8-foot T8 or T12 strip-type fixtures into energy efficient LED luminaires. High quality components and

More information

Innovative Lighting Smooth Light Recessed Luminaires

Innovative Lighting Smooth Light Recessed Luminaires Installation Guide Innovative Lighting Smooth Light LED Recessed Luminaires BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow these instructions will invalidate the warranty

More information

Important Safety Instructions. Important Safety Instructions

Important Safety Instructions. Important Safety Instructions Thank you for purchasing a DAGR Industrial Lighting fixture one of the most durable LED fixtures on the market. Our lights have been engineered, tested and certified to ensure optimum performance in the

More information

Installation Instructions

Installation Instructions Installation Instructions 3M Light Mat Series 3635-1000 Installation Bulletin 3635-1000 Release D, Effective July 2010 (Replaces C, Apr 2010) See Bulletin Change Summary at end of Bulletin Product Description

More information

LED RETROFIT CONVERSION KITS

LED RETROFIT CONVERSION KITS Engineered Products Company s LED RetroFit Conversion Kits convert older 4-foot and 8-foot T8 or T12 strip-type fixtures into energy efficient LED luminaires. High quality components and attractive design

More information

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for

More information

LED RETROFIT SOLUTIONS

LED RETROFIT SOLUTIONS The adoption of LED technology for general illumination systems is considered the attractive choice when compared against traditional linear fluorescent lamps. Engineered Products Company (EPCO) LED RetroFit

More information

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

MAXLITE RKT LED Retrofit Kit

MAXLITE RKT LED Retrofit Kit Operating Instructions MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside

More information

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always

More information

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

YP7999A1000 ControLinks Fuel Air Ratio Control Panel YP7999A1000 ControLinks Fuel Air Ratio Control Panel FEATURES INSTALLATION INSTRUCTIONS Pre-wired and ready to install Includes the R7999A control, wiring subbase and S7999D1048 touchscreen display Commission,

More information

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS READ AND FOLLOW THESE INSTRUCTIONS BEFORE INSTALLATION TO ENSURE PROPER AND SAFE OPERATION SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY

More information

SERVICE BY QUALIFIED PERSONNEL ONLY

SERVICE BY QUALIFIED PERSONNEL ONLY Installation Instructions Automatic Load Control Relay For Emergency Lighting! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

More information

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION SAFETY INSTRUCTIONS AND WARNINGS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY

More information

MaxLite LED Round Pendant Highbay Series

MaxLite LED Round Pendant Highbay Series General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP INSTALLATION INSTRUCTIONS READ AND FOLLOW THESE INSTRUCTIONS BEFORE INSTALLATION TO ENSURE PROPER AND SAFE OPERATION SAVE THESE INSTRUCTIONS LED EMERGENCY DRIVER

More information

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6 FV-08VQL6 FV-15VQL6 FV-11VQL6 2-3 5 5 6-8 FV-08VQL6 FV-11VQL6 11 Back cover Back cover Back cover FV-15VQL6 Thank you for purchasing this Panasonic product. For Your Safety To reduce the risk of injury,

More information

MaxLite LED Vapor Tight Linear Fixture

MaxLite LED Vapor Tight Linear Fixture General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

HPNLS-LO. Installation Manual

HPNLS-LO. Installation Manual Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES. Do not attempt to install or use the fixture without reading the installation instructions and safety labels completely. This could result in

More information

T6984F,G Electronic Floating Control Thermostats

T6984F,G Electronic Floating Control Thermostats T6984F,G Electronic Floating Control Thermostats FEATURES PRODUCT DATA P+I control action provides accurate, stable room temperature control. Used with ML644 Series 60 Direct Coupled Damper Actuators.

More information

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T7200D,E Series 2000 Commercial Microelectronic Thermostats T7200D,E Series 2000 Commercial Microelectronic Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T7200D,E Thermostats provide electronic control of 24 Vac commercial single-zone heating, ventilating

More information

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always

More information

HPNLS-RT. Installation Manual

HPNLS-RT. Installation Manual Installation Manual WARNING: Do not lift fixture by cables. This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/or putting undue pressure

More information

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

T8 Self Ballasted UL & CSA LED TUBE RETROFITS T8 Self Ballasted UL & CSA LED TUBE RETROFITS Sept. 2011 Part Numbers T8 LED TUBE TECHNICAL SPECIFICATIONS Part Numbers LR-T8-17W-3.2-1200 LR-T8-17W-4.5-1200 LR-T8-17W-6.5-1200 LRT8-23WW-FS2 LRT8-23CW-FS2

More information

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location: LUCE 1 TL indoor / damp Job/Location: Contractor: Prepared By: Job Type: Date: The LUCE-1TL thinline emergency ballast is designed to provide emergency illumination to existing or new fluorescent luminaires.

More information

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400 INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400 CAUTION: For safety and proper operation, read and follow instructions carefully before installation. FIELD INSTALLABLE

More information

Commercial/Industrial Combustion Control Level Three Announcement

Commercial/Industrial Combustion Control Level Three Announcement Commercial/Industrial Combustion Control Level Three Announcement SUBJECT: C6097 requiring venting Model Numbers Affected: C6097A and B Ref. Number L3-08-006 Issue Date 12/9/08 Author P.Yuen/L.Ziller Date

More information

CDL8 LED Architectural

CDL8 LED Architectural Project: Type: Model# CDL8 LED Architectural PRODUCT DESCRIPTION Retrofit Down lights The Luminoso 8 inch Commercial LED Downlight is damp rated, and suitable for 1-277V Input equipped with fire-rated

More information

LED ROUND MINI PANELS

LED ROUND MINI PANELS Our ASD LED Round Mini Panel is a cutting-edge choice for indoor lighting for both residential and commercial applications. This round lit mini panel features low energy consumption, a year warranty and

More information

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following: ILB-CP20-HE-A TBTS HIGH EFFICIENCY EMERGENCY LIGHTING EQUIPMENT FOR LED INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including

More information

TP970 SERIES ASPIRATING WALL BOX ASSEMBLIES BEFORE INSTALLATION

TP970 SERIES ASPIRATING WALL BOX ASSEMBLIES BEFORE INSTALLATION TP970 SERIES 14002424 ASPIRATING WALL ASSEMBLIES BEFORE INSTALLATION 1. The HP970 and TP970 Series Aspirating Wall Box Assembly (Fig. 1) is available in two versions: - 14002424-002 Aspirating Wall Box

More information

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/ CONTROL DEVICE UL 1008-BCELTS UL 924-Switch Bypass! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS

More information

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright T8 PBT8-DL5004EFX-U AC 100V-277V Day Light 5000K Pure Bright LED retrofits! Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! With the highest safety rating available, UL Listed,

More information

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S. LaceyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go!

More information

T7984 A,B,C Electronic Modulating Control Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in

More information

Installation guide. Philips EvoKit LED 2x4 and 2x2

Installation guide. Philips EvoKit LED 2x4 and 2x2 Installation guide Philips EvoKit LED 2x4 and 2x2 This installation guide is only valid for the following Philips EvoKit models: Products 2x4 EvoKit 2x4 P 36L 36W 835 2 0-0 7 G2 EvoKit 2x4 P 36L 36W 840

More information

Owner s Manual. High Output T5 Lunar Aqualight. Aquarium Light Fixture. Featuring: Directional Lunar Blue LEDs

Owner s Manual. High Output T5 Lunar Aqualight. Aquarium Light Fixture. Featuring: Directional Lunar Blue LEDs Owner s Manual High Output T5 Lunar Aqualight Aquarium Light Fixture Featuring: Directional Lunar Blue LEDs OwnMan_T5HO_LUNAR.indd 1 6/15/10 10:06 AM IMPORTANT SAFETY INSTRUCTIONS WARNING: To guard against

More information

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE ITM. / ART. 1165831 Model: LM56123 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly or installation,

More information

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071 SLATE UV Ampli-Check Flame Amplifier R8001S1071 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform.

More information

Service Manual Electric Cooktop

Service Manual Electric Cooktop Service Manual Electric Cooktop 318 202 105 (0311) THIS IS A BLANK PAGE Table of Contents I SAFE SERVICING PRACTICES... 1 PRODUCT FEATURES... 2 WIRING DIAGRAM... 3 SECTION A - INSTALLATION... 4 CUT-OUT

More information

LED Linear Design Highlights

LED Linear Design Highlights LED Linear Design Highlights Advanced Thermal Management Industry Leading Deep Fin Heat Sinks with Aircraft Grade Aluminum and 9 (23cm) [min] of perimeter conductive surface. Multiple Color Options Three

More information

Bdl60u Fluorescent Emergency Ballast

Bdl60u Fluorescent Emergency Ballast A Division Of Philips Electronics North America Corporation One- or two-lamp emergency; Universal input voltage: 120 through 277 V, 50 or 60 Hz; Replaces B60U Bdl60u Fluorescent Emergency Ballast Product

More information

Rope Light Wiring. wdmlighting.com

Rope Light Wiring. wdmlighting.com This user guide is to explain the steps necessary to use the specified and assure peak performance. Its intended use is for reference only, by a fully qualified electrician or technician. This document

More information

Lumination TM Volumetric Retrofit Kit

Lumination TM Volumetric Retrofit Kit GE Lighting Installation Guide Lumination TM Volumetric Retrofit Kit BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING AVERTISSEMENT RISK OF FIRE OR ELECTRIC SHOCK Luminaire wiring

More information

SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS

SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS AQUARIUM LED SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS FULL ONLINE INSTRUCTIONS: www.arcadia.systems READ AND FOLLOW ALL SAFETY INSTRUCTIONS KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE DANGER-

More information

Owner s Manual Compact Fluorescent Lunar Aqualight

Owner s Manual Compact Fluorescent Lunar Aqualight Owner s Manual Compact Fluorescent Lunar Aqualight Aquarium Light Fixture Featuring: Directional Lunar Blue LEDs IMPORTANT SAFETY INSTRUCTIONS WARNING: To guard against injury, basic safety precautions

More information

HE220, HE260 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat

More information

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination THE HIGH PERFORMANCE LED Fixture Series for General, Direct and Indirect Illumination KEY FEATURES INCLUDE: Advanced Thermal Management Industry Leading Deep Fin Heat Sinks with Aircraft Grade Aluminum

More information

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE TM ANYWHERE BY U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE 2017 Minka Lighting Inc. Manual design and all elements of manual design are protected by United States Federal and/or State

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

30-YEAR LIMITED WARRANTY

30-YEAR LIMITED WARRANTY PROGRESS LIGHTING 30-YEAR LIMITED WARRANTY PROGRESS LIGHTING FAN MOTORS ARE WARRANTED TO THE END USER TO BE FREE OF ELECTRICAL AND/OR MECHANICAL DEFECTS FOR A PERIOD OF 30 (THIRTY) YEARS FROM DATE OF SALE.

More information

LED Emergency Battery Backup

LED Emergency Battery Backup LED Emergency Battery Backup Installation Instructions Ordering Code: PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION: TROFFER INSTALLATION STRIP INSTALLATION INTRODUCTION & TABLE OF CONTENTS Ordering

More information

LIMITED LIFETIME WARRANTY

LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY Model No.: F0023 / F0024 aireryder ORIGINAL CEILING FAN LIMITED LIFETIME WARRANTY The limited lifetime warranty covers this ceiling fan, for residential use by the original purchaser,

More information

What You Need to Know About UL rd Edition

What You Need to Know About UL rd Edition What You Need to Know About UL 1598 3rd Edition Carl Bloomfield, Director of Business Services - Appliances & Lighting Introduction Prior to the first edition of UL 1598 in December 2000, there were multiple

More information

PSO Business Rebates Retrofit Lighting Technical Requirements

PSO Business Rebates Retrofit Lighting Technical Requirements PSO Business Rebates Retrofit Lighting General LED Requirements LED replacement and LED luminaires must be listed on the Design Lights Consortium (DLC) or ENERGY STAR Qualified Products List (QPL). DLC

More information

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not

More information

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product. Page 1 of 5 IS-S6-T rev.01 NOTE The following instructions provide general guidelines for product installation. For additional information consult the applicable electrical codes or contact factory directly

More information

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including

More information

LIGHT CHANNEL TRIM 1.6

LIGHT CHANNEL TRIM 1.6 2.75" (7cm) 0.75" (1.3cm) 12.5" - 120.5" (31.8cm - 306.1cm) 0.75" (1.3cm) 0.63" (1.6cm) 0.2" (0.5cm) 2.6" (6.6cm) Power Feed Junction Box Constraint Clip 2" (5.1cm) DESCRIPTION Light Channel Trim 1.6 provides

More information

DHL-LP-LED Low Profile LED Linear High/Low Bay

DHL-LP-LED Low Profile LED Linear High/Low Bay IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions

More information

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES Philips Lighting North America Philips Lighting Canada Ltd. Corporation 281 Hillmount Road, 200 Franklin Square Drive, Markham ON, Canada

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION 265100 - INTERIOR LIGHTING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Interior lighting fixtures, lamps, and ballasts. 2. Emergency lighting units. 3. Exit signs. 4.

More information

LED Edge-Lit Flat Panels

LED Edge-Lit Flat Panels ASD LED Edge Lit Flat Panels are modern cutting-edge fixtures with 13-up lm/w models made to DLC Premium specifications. Our Edge-lit panels are very rigid and measure only 1/2 thick making us one of the

More information

ESRB and ESRN Installation & Safety Instructions

ESRB and ESRN Installation & Safety Instructions B1784 ESRB and ESRN Installation & Safety Instructions IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW

More information

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and CAUTION symbols.

More information

AM Series Proportional Thermostatic Mixing Valve

AM Series Proportional Thermostatic Mixing Valve AM-1 1070 Series Proportional Thermostatic Mixing Valve PATENTED, WIT DUAL ASSE 1070 AND 1017 ERTIFIATION, IAPMO AND SA LISTING IN ONE VALVE PRODUT DATA PRODUT INFORMATION SPEIFIATIONS Media Temperature

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules PRODUCT DATA indicate the presence of flame when used with 7800 SERIES and R7140 Relay Modules.

More information

T4398A,B Precision Electric Heating Thermostat

T4398A,B Precision Electric Heating Thermostat T398A,B Precision Electric Heating Thermostat FEATURES PRODUCT DATA APPLICATION The T398 Electric Heating Thermostat provides precise, accurate line voltage control of electric heating equipment. A snap

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL Hover with DC motor 12/14 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION

More information

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Manifold Installation Controller MIC-180. Installation and Operation Instructions Manifold Installation Controller MIC-180 Installation and Operation Instructions For Use With Rheem-Ruud and Paloma Commercial Tankless Water Heaters Table of Contents Safety Information... 1-2 Manifold

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA) R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings

More information

Lunera Smart T8 4ft. Installation Guide. Installation Description

Lunera Smart T8 4ft. Installation Guide. Installation Description Installation Guide Lunera Smart T8 4ft Smart Lamp Replacement for 4ft Fluorescent T8 Type B - Single-Ended, Ballast Bypassed Installation Description The LUNERA SMART T8 4FT lamp functions both as an energy-saving

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL VANTAGE with DC motor 12/14 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION

More information

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming Fluorescent Dimming s Hi-lume 3D Architectural Dimming Hi-lume 3D Overview 369-280f 1 03.08.12 Hi-lume 3D architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements.

More information

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001 SLATE Sub-Base Module R8001S9001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information